1
|
Ombelet S, Natale A, Ronat JB, Vandenberg O, Hardy L, Jacobs J. Evaluation of MicroScan Bacterial Identification Panels for Low-Resource Settings. Diagnostics (Basel) 2021; 11:349. [PMID: 33669829 PMCID: PMC7922174 DOI: 10.3390/diagnostics11020349] [Citation(s) in RCA: 5] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/17/2021] [Revised: 02/16/2021] [Accepted: 02/17/2021] [Indexed: 12/12/2022] Open
Abstract
Bacterial identification is challenging in low-resource settings (LRS). We evaluated the MicroScan identification panels (Beckman Coulter, Brea, CA, USA) as part of Médecins Sans Frontières' Mini-lab Project. The MicroScan Dried Overnight Positive ID Type 3 (PID3) panels for Gram-positive organisms and Dried Overnight Negative ID Type 2 (NID2) panels for Gram-negative organisms were assessed with 367 clinical isolates from LRS. Robustness was studied by inoculating Gram-negative species on the Gram-positive panel and vice versa. The ease of use of the panels and readability of the instructions for use (IFU) were evaluated. Of species represented in the MicroScan database, 94.6% (185/195) of Gram-negative and 85.9% (110/128) of Gram-positive isolates were correctly identified up to species level. Of species not represented in the database (e.g., Streptococcus suis and Bacillus spp.), 53.1% out of 49 isolates were incorrectly identified as non-related bacterial species. Testing of Gram-positive isolates on Gram-negative panels and vice versa (n = 144) resulted in incorrect identifications for 38.2% of tested isolates. The readability level of the IFU was considered too high for LRS. Inoculation of the panels was favorably evaluated, whereas the visual reading of the panels was considered error-prone. In conclusion, the accuracy of the MicroScan identification panels was excellent for Gram-negative species and good for Gram-positive species. Improvements in stability, robustness, and ease of use have been identified to assure adaptation to LRS constraints.
Collapse
Affiliation(s)
- Sien Ombelet
- Department of Clinical Sciences, Institute of Tropical Medicine, 2000 Antwerp, Belgium; (L.H.); (J.J.)
- Immunology & Microbiology Department, KU Leuven, 3000 Leuven, Belgium
| | - Alessandra Natale
- Médecins Sans Frontières, Operational Center Paris, 75019 Paris, France; (A.N.); (J.-B.R.)
| | - Jean-Baptiste Ronat
- Médecins Sans Frontières, Operational Center Paris, 75019 Paris, France; (A.N.); (J.-B.R.)
- Team ReSIST, INSERM U1184, School of Medicine, University Paris-Saclay, 94807 Villejuif, France
- Bacteriology-Hygiene Unit, Assistance Publique—Hôpitaux de Paris, Bicêtre Hospital, 94270 Le Kremlin-Bicêtre, France
| | - Olivier Vandenberg
- Center for Environmental Health and Occupational Health, School of Public Health, Université Libre de Bruxelles (ULB), 1050 Brussels, Belgium;
- Innovation and Business Development Unit, Laboratoire Hospitalier Universitaire de Bruxelles—Universitair Laboratorium Brussel (LHUB-ULB), Université Libre de Bruxelles (ULB), 1050 Brussels, Belgium
- Division of Infection and Immunity, Faculty of Medical Sciences, University College London, London WC1E 6BT, UK
| | - Liselotte Hardy
- Department of Clinical Sciences, Institute of Tropical Medicine, 2000 Antwerp, Belgium; (L.H.); (J.J.)
| | - Jan Jacobs
- Department of Clinical Sciences, Institute of Tropical Medicine, 2000 Antwerp, Belgium; (L.H.); (J.J.)
- Immunology & Microbiology Department, KU Leuven, 3000 Leuven, Belgium
| |
Collapse
|
2
|
Jacobs J, Kühne V, Lunguya O, Affolabi D, Hardy L, Vandenberg O. Implementing COVID-19 (SARS-CoV-2) Rapid Diagnostic Tests in Sub-Saharan Africa: A Review. Front Med (Lausanne) 2020; 7:557797. [PMID: 33195307 PMCID: PMC7662157 DOI: 10.3389/fmed.2020.557797] [Citation(s) in RCA: 40] [Impact Index Per Article: 8.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/30/2020] [Accepted: 09/15/2020] [Indexed: 01/23/2023] Open
Abstract
Introduction: For the COVID-19 (SARS-CoV-2) response, COVID-19 antigen (Ag), and antibody (Ab) rapid diagnostic tests (RDTs) are expected to complement central molecular testing particularly in low-resource settings. The present review assesses requirements for implementation of COVID-19 RDTs in sub-Saharan Africa. Methods: Review of PubMed-published articles assessing COVID-19 RDTs complemented with Instructions for Use (IFU) of products. Results: In total 47 articles on two COVID-19 Ag RDTs and 54 COVID-19 Ab RDTs and IFUs of 20 COVID-19 Ab RDTs were retrieved. Only five COVID-19 Ab RDTs (9.3%) were assessed with capillary blood sampling at the point-of-care; none of the studies were conducted in sub-Saharan Africa. Sampling: Challenges for COVID-19 Ag RDTs include nasopharyngeal sampling (technique, biosafety) and sample stability; for COVID-19 Ab RDTs equivalence of whole blood vs. plasma/serum needs further validation (assessed for only eight (14.8%) products). Sensitivity-Specificity: sensitivity of COVID-19 Ag and Ab RDTs depend on viral load (antigen) and timeframe (antibody), respectively; COVID-19 Ab tests have lower sensitivity compared to laboratory test platforms and the kinetics of IgM and IgG are very similar. Reported specificity was high but has not yet been assessed against tropical pathogens. Kit configuration: For COVID-19 Ag RDTs, flocked swabs should be added to the kit; for COVID-19 Ab RDTs, finger prick sampling materials, transfer devices, and controls should be added (currently only supplied in 15, 5, and 1/20 products). Usability and Robustness: some COVID-19 Ab RDTs showed high proportions of faint lines (>40%) or invalid results (>20%). Shortcomings were reported for buffer vials (spills, air bubbles) and their instructions for use. Stability: storage temperature was ≤ 30°C for all but one RDT, in-use and result stability were maximal at 1 h and 30 min, respectively. Integration in the healthcare setting requires a target product profile, landscape overview of technologies, certified manufacturing capacity, a sustainable market, and a stringent but timely regulation. In-country deployment depends on integration in the national laboratory network. Discussion/Conclusion: Despite these limitations, successful implementation models in triage, contact tracing, and surveillance have been proposed, in particular for COVID-19 Ab RDTs. Valuable experience is available from implementation of other disease-specific RDTs in sub-Saharan Africa.
Collapse
Affiliation(s)
- Jan Jacobs
- Department of Clinical Sciences, Institute of Tropical Medicine Antwerp, Antwerp, Belgium
- Department of Microbiology, Immunology and Transplantation, KU Leuven, Leuven, Belgium
| | - Vera Kühne
- Department of Clinical Sciences, Institute of Tropical Medicine Antwerp, Antwerp, Belgium
| | - Octavie Lunguya
- Department of Clinical Microbiology, National Institute of Biomedical Research, Kinshasa, Democratic Republic of Congo
- Microbiology Unit, Department of Clinical Biology, University Hospital of Kinshasa, Kinshasa, Democratic Republic of Congo
| | - Dissou Affolabi
- Clinical Microbiology, Centre National Hospitalier et Universitaire Hubert Koutoukou MAGA, Cotonou, Benin
| | - Liselotte Hardy
- Department of Clinical Sciences, Institute of Tropical Medicine Antwerp, Antwerp, Belgium
| | - Olivier Vandenberg
- Center for Environmental Health and Occupational Health, School of Public Health, Université Libre de Bruxelles (ULB), Brussels, Belgium
- Innovation and Business Development Unit, Laboratoire Hospitalier Universitaire de Bruxelles - Universitair Laboratorium Brussel (LHUB-ULB), ULB, Brussels, Belgium
- Division of Infection and Immunity, Faculty of Medical Sciences, University College London, London, United Kingdom
| |
Collapse
|
3
|
Storey HL, Agarwal N, Cantera J, Golden A, Gallo K, Herrick T, Belizario V, Kihara J, Mwandawiro C, Cadwallader B, de los Santos T. Formative research to inform development of a new diagnostic for soil-transmitted helminths: Going beyond the laboratory to ensure access to a needed product. PLoS Negl Trop Dis 2019; 13:e0007372. [PMID: 31150389 PMCID: PMC6561600 DOI: 10.1371/journal.pntd.0007372] [Citation(s) in RCA: 4] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/19/2018] [Revised: 06/12/2019] [Accepted: 04/09/2019] [Indexed: 12/11/2022] Open
Abstract
Soil-transmitted helminths (STHs) affect more than 1.5 billion people. The global strategy to control STH infections requires periodic mass drug administration (MDA) based on prevalence among populations at risk determined by diagnostic testing. Widely used copromicroscopy methods to detect infection, however, have low sensitivity as the prevalence and intensity of STH infections decline with repeated MDA. More sensitive diagnostic tools are needed to inform program decision-making. Using an integrated product development process, PATH conducted qualitative and quantitative formative research to inform the design and development of a more sensitive test for STH infections. The research, grounded in a conceptual framework for ensuring access to health products, involved stakeholder analysis, key opinion leader interviews, observational site visits of ongoing STH surveillance programs, and market research including market sizing, costing and willingness-to-pay analyses. Stakeholder analysis identified key groups and proposed strategic engagement of stakeholders during product development. Interviews highlighted features, motivations and concerns that are important for guiding design and implementation of new STH diagnostics. Process mapping outlined current STH surveillance workflows in Kenya and the Philippines. Market sizing in 2016 was estimated around half a million tests for lower STH burden countries, and 1-2 million tests for higher STH burden countries. The cost of commodities per patient for a molecular STH diagnostic may be around $10, 3-4 times higher than copromicroscopy methods, though savings may be possible in time and staffing requirements. The market is highly price sensitive as even at $5 per test, only 27% of respondents thought the test would be used by surveillance programs. A largely subsidized STH control strategy and a semi-functional Kato-Katz test may have created few incentives for manufacturers to innovate in STH diagnostics. Diverse partnerships, as well as balancing needs and expectations for new STH diagnostics are necessary to ensure access to needed products.
Collapse
Affiliation(s)
- Helen L. Storey
- PATH, Seattle, Washington, United States of America
- * E-mail:
| | - Neha Agarwal
- PATH, Seattle, Washington, United States of America
| | | | | | - Kerry Gallo
- PATH, Seattle, Washington, United States of America
| | - Tara Herrick
- PATH, Seattle, Washington, United States of America
| | | | - Jimmy Kihara
- Kenya Medical Research Institute, Nairobi, Kenya
| | | | | | | |
Collapse
|