1
|
Gerwert K, Schörner S, Großerueschkamp F, Kraeft AL, Schuhmacher D, Sternemann C, Feder IS, Wisser S, Lugnier C, Arnold D, Teschendorf C, Mueller L, Timmesfeld N, Mosig A, Reinacher-Schick A, Tannapfel A. Fast and label-free automated detection of microsatellite status in early colon cancer using artificial intelligence integrated infrared imaging. Eur J Cancer 2023; 182:122-131. [PMID: 36773401 DOI: 10.1016/j.ejca.2022.12.026] [Citation(s) in RCA: 3] [Impact Index Per Article: 1.5] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/04/2022] [Revised: 12/14/2022] [Accepted: 12/23/2022] [Indexed: 01/11/2023]
Abstract
PURPOSE Microsatellite instability (MSI) due to mismatch repair (MMR) defects accounts for 15-20% of colon cancers (CC). MSI testing is currently standard of care in CC with immunohistochemistry of the four MMR proteins representing the gold standard. Instead, label-free quantum cascade laser (QCL) based infrared (IR) imaging combined with artificial intelligence (AI) may classify MSI/microsatellite stability (MSS) in unstained tissue sections user-independently and tissue preserving. METHODS Paraffin-embedded unstained tissue sections of early CC from patients participating in the multicentre AIO ColoPredict Plus (CPP) 2.0 registry were analysed after dividing into three groups (training, test, and validation). IR images of tissue sections using QCL-IR microscopes were classified by AI (convolutional neural networks [CNN]) using a two-step approach. The first CNN (modified U-Net) detected areas of cancer while the second CNN (VGG-Net) classified MSI/MSS. End-points were area under receiver operating characteristic (AUROC) and area under precision recall curve (AUPRC). RESULTS The cancer detection in the first step was based on 629 patients (train n = 273, test n = 138, and validation n = 218). Resulting classification AUROC was 1.0 for the validation dataset. The second step classifying MSI/MSS was performed on 547 patients (train n = 331, test n = 69, and validation n = 147) reaching AUROC and AUPRC of 0.9 and 0.74, respectively, for the validation cohort. CONCLUSION Our novel label-free digital pathology approach accurately and rapidly classifies MSI vs. MSS. The tissue sections analysed were not processed leaving the sample unmodified for subsequent analyses. Our approach demonstrates an AI-based decision support tool potentially driving improved patient stratification and precision oncology in the future.
Collapse
Affiliation(s)
- Klaus Gerwert
- Center for Protein Diagnostics (PRODI), Deptartment of Biophysics, Ruhr University Bochum, Bochum, Germany
| | - Stephanie Schörner
- Center for Protein Diagnostics (PRODI), Deptartment of Biophysics, Ruhr University Bochum, Bochum, Germany
| | - Frederik Großerueschkamp
- Center for Protein Diagnostics (PRODI), Deptartment of Biophysics, Ruhr University Bochum, Bochum, Germany
| | - Anna-Lena Kraeft
- Deptartment of Haematology, Oncology and Palliative Care, St. Josef-Hospital, Ruhr University Bochum, Bochum, Germany
| | - David Schuhmacher
- Center for Protein Diagnostics (PRODI), Dept. of Bioinformatics, Ruhr University Bochum, Bochum, Germany
| | - Carlo Sternemann
- Institut für Pathologie, Ruhr-Universität Bochum, Bochum, Germany
| | - Inke S Feder
- Institut für Pathologie, Ruhr-Universität Bochum, Bochum, Germany
| | - Sarah Wisser
- Institut für Pathologie, Ruhr-Universität Bochum, Bochum, Germany
| | - Celine Lugnier
- Deptartment of Haematology, Oncology and Palliative Care, St. Josef-Hospital, Ruhr University Bochum, Bochum, Germany
| | - Dirk Arnold
- Oncology, Haematology, Palliative Care Deptartment Asklepios Tumorzentrum Hamburg AK Altona, Hamburg, Germany
| | | | - Lothar Mueller
- Onkologie UnterEms Leer Emden Papenburg, Onkologische Schwerpunktpraxis Leer-Emden, Leer, Germany
| | - Nina Timmesfeld
- Medical Informatics, Biometry and Epidemiology, Ruhr University Bochum, Bochum, Germany
| | - Axel Mosig
- Center for Protein Diagnostics (PRODI), Dept. of Bioinformatics, Ruhr University Bochum, Bochum, Germany
| | - Anke Reinacher-Schick
- Deptartment of Haematology, Oncology and Palliative Care, St. Josef-Hospital, Ruhr University Bochum, Bochum, Germany
| | - Andrea Tannapfel
- Institut für Pathologie, Ruhr-Universität Bochum, Bochum, Germany.
| |
Collapse
|
2
|
Schuhmacher D, Schörner S, Küpper C, Großerueschkamp F, Sternemann C, Lugnier C, Kraeft AL, Jütte H, Tannapfel A, Reinacher-Schick A, Gerwert K, Mosig A. A framework for falsifiable explanations of machine learning models with an application in computational pathology. Med Image Anal 2022; 82:102594. [DOI: 10.1016/j.media.2022.102594] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/22/2021] [Revised: 08/11/2022] [Accepted: 08/18/2022] [Indexed: 10/31/2022]
|
3
|
Rehman HU, Tafintseva V, Zimmermann B, Solheim JH, Virtanen V, Shaikh R, Nippolainen E, Afara I, Saarakkala S, Rieppo L, Krebs P, Fomina P, Mizaikoff B, Kohler A. Preclassification of Broadband and Sparse Infrared Data by Multiplicative Signal Correction Approach. Molecules 2022; 27:2298. [PMID: 35408697 PMCID: PMC9000438 DOI: 10.3390/molecules27072298] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/16/2022] [Revised: 03/28/2022] [Accepted: 03/30/2022] [Indexed: 02/04/2023] Open
Abstract
Preclassification of raw infrared spectra has often been neglected in scientific literature. Separating spectra of low spectral quality, due to low signal-to-noise ratio, presence of artifacts, and low analyte presence, is crucial for accurate model development. Furthermore, it is very important for sparse data, where it becomes challenging to visually inspect spectra of different natures. Hence, a preclassification approach to separate infrared spectra for sparse data is needed. In this study, we propose a preclassification approach based on Multiplicative Signal Correction (MSC). The MSC approach was applied on human and the bovine knee cartilage broadband Fourier Transform Infrared (FTIR) spectra and on a sparse data subset comprising of only seven wavelengths. The goal of the preclassification was to separate spectra with analyte-rich signals (i.e., cartilage) from spectra with analyte-poor (and high-matrix) signals (i.e., water). The human datasets 1 and 2 contained 814 and 815 spectra, while the bovine dataset contained 396 spectra. A pure water spectrum was used as a reference spectrum in the MSC approach. A threshold for the root mean square error (RMSE) was used to separate cartilage from water spectra for broadband and the sparse spectral data. Additionally, standard noise-to-ratio and principle component analysis were applied on broadband spectra. The fully automated MSC preclassification approach, using water as reference spectrum, performed as well as the manual visual inspection. Moreover, it enabled not only separation of cartilage from water spectra in broadband spectral datasets, but also in sparse datasets where manual visual inspection cannot be applied.
Collapse
Affiliation(s)
- Hafeez Ur Rehman
- Faculty of Science and Technology, Norwegian University of Life Sciences, 1430 Ås, Norway; (V.T.); (B.Z.); (J.H.S.); (A.K.)
| | - Valeria Tafintseva
- Faculty of Science and Technology, Norwegian University of Life Sciences, 1430 Ås, Norway; (V.T.); (B.Z.); (J.H.S.); (A.K.)
| | - Boris Zimmermann
- Faculty of Science and Technology, Norwegian University of Life Sciences, 1430 Ås, Norway; (V.T.); (B.Z.); (J.H.S.); (A.K.)
| | - Johanne Heitmann Solheim
- Faculty of Science and Technology, Norwegian University of Life Sciences, 1430 Ås, Norway; (V.T.); (B.Z.); (J.H.S.); (A.K.)
| | - Vesa Virtanen
- Research Unit of Medical Imaging, Physics and Technology, Faculty of Medicine, University of Oulu, 90570 Oulu, Finland; (V.V.); (S.S.); (L.R.)
| | - Rubina Shaikh
- Department of Applied Physics, University of Eastern Finland, 70210 Kuopio, Finland; (R.S.); (E.N.); (I.A.)
- Department of Orthopedics, Traumatology, Hand Surgery, Kuopio University Hospital, 70210 Kuopio, Finland
| | - Ervin Nippolainen
- Department of Applied Physics, University of Eastern Finland, 70210 Kuopio, Finland; (R.S.); (E.N.); (I.A.)
| | - Isaac Afara
- Department of Applied Physics, University of Eastern Finland, 70210 Kuopio, Finland; (R.S.); (E.N.); (I.A.)
| | - Simo Saarakkala
- Research Unit of Medical Imaging, Physics and Technology, Faculty of Medicine, University of Oulu, 90570 Oulu, Finland; (V.V.); (S.S.); (L.R.)
| | - Lassi Rieppo
- Research Unit of Medical Imaging, Physics and Technology, Faculty of Medicine, University of Oulu, 90570 Oulu, Finland; (V.V.); (S.S.); (L.R.)
| | - Patrick Krebs
- Institute of Analytical and Bioanalytical Chemistry, Ulm University, 89081 Ulm, Germany; (P.K.); (P.F.); (B.M.)
| | - Polina Fomina
- Institute of Analytical and Bioanalytical Chemistry, Ulm University, 89081 Ulm, Germany; (P.K.); (P.F.); (B.M.)
| | - Boris Mizaikoff
- Institute of Analytical and Bioanalytical Chemistry, Ulm University, 89081 Ulm, Germany; (P.K.); (P.F.); (B.M.)
| | - Achim Kohler
- Faculty of Science and Technology, Norwegian University of Life Sciences, 1430 Ås, Norway; (V.T.); (B.Z.); (J.H.S.); (A.K.)
| |
Collapse
|
4
|
Al Jedani S, Whitley CA, Ellis BG, Triantafyllou A, Smith CI, Gunning PJ, Gardner P, Risk JM, Weightman P, Barrett SD. Image fusion of IR and optical microscopy for mapping of biomolecules in tissue. Analyst 2021; 146:5848-5854. [PMID: 34498612 PMCID: PMC8475953 DOI: 10.1039/d1an01161h] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/30/2021] [Accepted: 08/30/2021] [Indexed: 11/21/2022]
Abstract
It is shown that a pixel-level image fusion technique can produce images that combine the spatial resolution of optical microscopy images of haematoxylin and eosin (H&E) stained tissue with the chemical information in Fourier transform infrared (FTIR) images. The fused images show minimal distortion and the higher spatial resolution of the H&E images overcomes the diffraction limit on the spatial resolution of the FTIR images. A consideration of the FTIR spectra of nucleic acids and collagen can explain the changes in contrast between non-cancerous oral epithelium and underlying stroma within fused images formed by combining an H&E stain of oral tissue with FTIR images of the tissue obtained at a number of wavenumbers.
Collapse
Affiliation(s)
- Safaa Al Jedani
- Department of Physics, University of Liverpool, L69 7ZE, UK.
| | - Conor A Whitley
- Department of Physics, University of Liverpool, L69 7ZE, UK.
| | - Barnaby G Ellis
- Department of Physics, University of Liverpool, L69 7ZE, UK.
| | - Asterios Triantafyllou
- Department of Pathology, Liverpool Clinical Laboratories, University of Liverpool, Liverpool, L69 3GA, UK
| | | | - Philip J Gunning
- Department of Molecular and Clinical Cancer Medicine, Institute of Systems, Molecular and Integrative Biology, University of Liverpool, L3 9TA, UK
| | - Peter Gardner
- Manchester Institute of Biotechnology, University of Manchester, 131 Princess Street, Manchester, M1 7DN, UK
| | - Janet M Risk
- Department of Molecular and Clinical Cancer Medicine, Institute of Systems, Molecular and Integrative Biology, University of Liverpool, L3 9TA, UK
| | - Peter Weightman
- Department of Physics, University of Liverpool, L69 7ZE, UK.
| | - Steve D Barrett
- Department of Physics, University of Liverpool, L69 7ZE, UK.
| |
Collapse
|
5
|
Boutegrabet W, Guenot D, Bouché O, Boulagnon-Rombi C, Marchal Bressenot A, Piot O, Gobinet C. Automatic Identification of Paraffin Pixels on FTIR Images Acquired on FFPE Human Samples. Anal Chem 2021; 93:3750-3761. [PMID: 33590761 DOI: 10.1021/acs.analchem.0c03910] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/12/2022]
Abstract
The transfer of mid-infrared spectral histopathology to the clinic will be possible provided that its application in clinical practice is simple. Rapid analysis of formalin-fixed paraffin-embedded (FFPE) tissue section is thus a prerequisite. The chemical dewaxing of these samples before image acquisition used by the majority of studies is in contradiction with this principle. Fortunately, the in silico analysis of the images acquired on FFPE samples is possible using extended multiplicative signal correction (EMSC). However, the removal of pure paraffin pixels is essential to perform a relevant classification of tissue spectra. So far, this task was possible only if using manual and subjective histogram analysis. In this article, we thus propose a new automatic and multivariate methodology based on the analysis of optimized combinations of EMSC regression coefficients by validity indices and KMeans clustering to separate paraffin and tissue pixels. The validation of our method is performed using simulated infrared spectral images by measuring the Jaccard index between our partitions and the image model, with values always over 0.90 for diverse baseline complexity and signal-to-noise ratio. These encouraging results were also validated on real images by comparing our method with classical ones and by computing the Jaccard index between our partitions and the KMeans partitions obtained on the infrared image acquired on the same samples but after chemical dewaxing, with values always over 0.84.
Collapse
Affiliation(s)
- Warda Boutegrabet
- Institut National de la Santé et de la Recherche Médicale, IRFAC Inserm U1113, Université de Strasbourg (Unistra), 3 avenue Molière, 67200 Strasbourg, France.,BioSpecT EA 7506, Université de Reims Champagne Ardenne, 51 rue Cognacq-Jay, 51097 Reims, France
| | - Dominique Guenot
- Institut National de la Santé et de la Recherche Médicale, IRFAC Inserm U1113, Université de Strasbourg (Unistra), 3 avenue Molière, 67200 Strasbourg, France
| | - Olivier Bouché
- BioSpecT EA 7506, Université de Reims Champagne Ardenne, 51 rue Cognacq-Jay, 51097 Reims, France.,Hepato-Gastroenterology Department, CHU de Reims, rue du Général Koenig, 51092 Reims, France
| | - Camille Boulagnon-Rombi
- MEDyC CNRS UMR 7369, Université de Reims Champagne Ardenne, 51 rue Cognacq-Jay, 51097 Reims, France.,Biopathology Laboratory, CHU de Reims, rue du Général Koenig, 51092 Reims, France
| | - Aude Marchal Bressenot
- BioSpecT EA 7506, Université de Reims Champagne Ardenne, 51 rue Cognacq-Jay, 51097 Reims, France.,Biopathology Laboratory, CHU de Reims, rue du Général Koenig, 51092 Reims, France
| | - Olivier Piot
- BioSpecT EA 7506, Université de Reims Champagne Ardenne, 51 rue Cognacq-Jay, 51097 Reims, France.,Platform of Cellular and Tissular Imaging (PICT), 51 rue Cognacq-Jay, 51097 Reims, France
| | - Cyril Gobinet
- BioSpecT EA 7506, Université de Reims Champagne Ardenne, 51 rue Cognacq-Jay, 51097 Reims, France
| |
Collapse
|