Zatkalíková V, Podhorský Š, Štrbák M, Liptáková T, Markovičová L, Kuchariková L. Plasma Electrolytic Polishing-An Ecological Way for Increased Corrosion Resistance in Austenitic Stainless Steels. MATERIALS 2022; 15:ma15124223. [PMID: 35744281 PMCID: PMC9231404 DOI: 10.3390/ma15124223] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 05/11/2022] [Revised: 06/09/2022] [Accepted: 06/13/2022] [Indexed: 12/10/2022]
Abstract
Plasma electrolytic polishing (PEP) is an environment-friendly alternative to the conventional electrochemical polishing (EP), giving optimal surface properties and improved corrosion resistance with minimum energy and time consumption, which leads to both economic and environmental benefits. This paper is focused on the corrosion behavior of PEP treated AISI 316L stainless steel widely used as a biomaterial. Corrosion resistance of plasma electrolytic polished surfaces without/with chemical pretreatment (acid cleaning) is evaluated and compared with original non-treated (as received) surfaces by three independent test methods: electrochemical impedance spectroscopy (EIS), potentiodynamic polarization (PP), and exposure immersion test. All corrosion tests are carried out in the 0.9 wt.% NaCl solution at a temperature of 37 ± 0.5 °C to simulate the internal environment of a human body. The quality of tested surfaces is also characterized by optical microscopy and by the surface roughness parameters. The results obtained indicated high corrosion resistance of PEP treated surfaces also without chemical pretreatment, which increases the ecological benefits of PEP technology.
Collapse
Affiliation(s)
- Viera Zatkalíková
- Department of Materials Engineering, Faculty of Mechanical Engineering, University of Žilina, Univerzitná 8215/1, 010 26 Žilina, Slovakia; (M.Š.); (T.L.); (L.M.); (L.K.)
- Correspondence: ; Tel.: +421-41-513-2610
| | - Štefan Podhorský
- Institute of Production Technologies, Faculty of Materials Science and Technology, Slovak University of Technology in Bratislava, Jána Bottu č. 2781/25, 917 24 Trnava, Slovakia;
| | - Milan Štrbák
- Department of Materials Engineering, Faculty of Mechanical Engineering, University of Žilina, Univerzitná 8215/1, 010 26 Žilina, Slovakia; (M.Š.); (T.L.); (L.M.); (L.K.)
- Research Centre UNIZA, University of Žilina, Univerzitná 8215/1, 010 26 Žilina, Slovakia
| | - Tatiana Liptáková
- Department of Materials Engineering, Faculty of Mechanical Engineering, University of Žilina, Univerzitná 8215/1, 010 26 Žilina, Slovakia; (M.Š.); (T.L.); (L.M.); (L.K.)
| | - Lenka Markovičová
- Department of Materials Engineering, Faculty of Mechanical Engineering, University of Žilina, Univerzitná 8215/1, 010 26 Žilina, Slovakia; (M.Š.); (T.L.); (L.M.); (L.K.)
| | - Lenka Kuchariková
- Department of Materials Engineering, Faculty of Mechanical Engineering, University of Žilina, Univerzitná 8215/1, 010 26 Žilina, Slovakia; (M.Š.); (T.L.); (L.M.); (L.K.)
| |
Collapse
|
2
|
Corrosion Resistance of AISI 316L Stainless Steel Biomaterial after Plasma Immersion Ion Implantation of Nitrogen. MATERIALS 2021; 14:ma14226790. [PMID: 34832193 PMCID: PMC8620768 DOI: 10.3390/ma14226790] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 10/04/2021] [Revised: 11/03/2021] [Accepted: 11/05/2021] [Indexed: 12/02/2022]
Abstract
Plasma immersion ion implantation (PIII) of nitrogen is low-temperature surface technology which enables the improvement of tribological properties without a deterioration of the corrosion behavior of austenitic stainless steels. In this paper the corrosion properties of PIII-treated AISI 316L stainless steel surfaces are evaluated by electrochemical impedance spectroscopy (EIS), potentiodynamic polarization (PP) and exposure immersion tests (all carried out in the 0.9 wt. % NaCl solution at 37 ± 0.5 °C) and compared with a non-treated surface. Results of the three performed independent corrosion tests consistently confirmed a significant increase in the corrosion resistance after two doses of PIII nitriding.
Collapse
|
3
|
Anodized Biomedical Stainless-Steel Mini-Implant for Rapid Recovery in a Rabbit Model. METALS 2021. [DOI: 10.3390/met11101575] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 01/11/2023]
Abstract
The study aimed to analyze the recovery period of the anodized 316L biomedical stainless steel (BSS) mini-implant through its implantation on femur of rabbit model. The 316L BSS mini-implant was modified by an electrochemical anodization approach with different voltages. The anodized samples were characterized via field-emission scanning electron microscopy, X-ray diffractometry, and X-ray photoelectron spectroscopy. The biocompatibility was assessed by cell culture assay. The anodized mini-implant was implanted on rabbit’s femur then evaluated histologically after 4 and 8 weeks. Analytical results indicated that the topography of the anodized mini-implant at 5 V for 5 min consisted of a dual (micro/nano) porous structure. Oxide film of Cr2O3 was formed on the surface of anodized mini-implant after anodizing with 5 V for 5 min. In vitro cell culture assay revealed that fibroblast cells (NIH-3T3) on the anodized samples were more firmly attached as compared with the control sample. Moreover, histological analysis demonstrated that the anodized mini-implant improved bone recovering at 4 weeks after implantation. Thus, this study suggests that the anodized 316L BSS mini-implant could be a potential choice as anchorage device for effective and efficient orthodontic treatment.
Collapse
|
4
|
Surface Characteristics and Cell Adhesion Behaviors of the Anodized Biomedical Stainless Steel. APPLIED SCIENCES-BASEL 2020. [DOI: 10.3390/app10186275] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 12/17/2022]
Abstract
In this study, an electrochemical anodizing method was applied as surface modification of the 316L biomedical stainless steel (BSS). The surface properties, microstructural characteristics, and biocompatibility responses of the anodized 316L BSS specimens were elucidated through scanning electron microscopy, X-ray photoelectron spectroscopy, X-ray diffractometry, transmission electron microscopy, and in vitro cell culture assay. Analytical results revealed that the oxide layer of dichromium trioxide (Cr2O3) was formed on the modified 316L BSS specimens after the different anodization modifications. Moreover, a dual porous (micro/nanoporous) topography can also be discovered on the surface of the modified 316L BSS specimens. The microstructure of the anodized oxide layer was composed of amorphous austenite phase and nano-Cr2O3. Furthermore, in vitro cell culture assay also demonstrated that the osteoblast-like cells (MG-63) on the anodized 316L BSS specimens were completely adhered and covered as compared with the unmodified 316L BSS specimen. As a result, the anodized 316L BSS with a dual porous (micro/nanoporous) oxide layer has great potential to induce cell adhesion and promote bone formation.
Collapse
|
5
|
Cosma C, Kessler J, Gebhardt A, Campbell I, Balc N. Improving the Mechanical Strength of Dental Applications and Lattice Structures SLM Processed. MATERIALS (BASEL, SWITZERLAND) 2020; 13:E905. [PMID: 32085482 PMCID: PMC7078848 DOI: 10.3390/ma13040905] [Citation(s) in RCA: 13] [Impact Index Per Article: 3.3] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 01/21/2020] [Revised: 02/10/2020] [Accepted: 02/15/2020] [Indexed: 01/07/2023]
Abstract
To manufacture custom medical parts or scaffolds with reduced defects and high mechanical characteristics, new research on optimizing the selective laser melting (SLM) parameters are needed. In this work, a biocompatible powder, 316L stainless steel, is characterized to understand the particle size, distribution, shape and flowability. Examination revealed that the 316L particles are smooth, nearly spherical, their mean diameter is 39.09 μm and just 10% of them hold a diameter less than 21.18 μm. SLM parameters under consideration include laser power up to 200 W, 250-1500 mm/s scanning speed, 80 μm hatch spacing, 35 μm layer thickness and a preheated platform. The effect of these on processability is evaluated. More than 100 samples are SLM-manufactured with different process parameters. The tensile results show that is possible to raise the ultimate tensile strength up to 840 MPa, adapting the SLM parameters for a stable processability, avoiding the technological defects caused by residual stress. Correlating with other recent studies on SLM technology, the tensile strength is 20% improved. To validate the SLM parameters and conditions established, complex bioengineering applications such as dental bridges and macro-porous grafts are SLM-processed, demonstrating the potential to manufacture medical products with increased mechanical resistance made of 316L.
Collapse
Affiliation(s)
- Cosmin Cosma
- Department of Manufacturing Engineering, Technical University of Cluj-Napoca, 400641 Cluj-Napoca, Romania;
| | - Julia Kessler
- Institute for Toolless Fabrication, 52074 Aachen, Germany;
| | - Andreas Gebhardt
- Department of Mechanical Engineering and Mechatronics, FH Aachen University of Applied Sciences, 52064 Aachen, Germany;
| | - Ian Campbell
- Loughborough Design School, University Loughborough, Loughborough LE11 3TU, Leics, UK;
| | - Nicolae Balc
- Department of Manufacturing Engineering, Technical University of Cluj-Napoca, 400641 Cluj-Napoca, Romania;
| |
Collapse
|
6
|
From Austenitic Stainless Steel to Expanded Austenite-S Phase: Formation, Characteristics and Properties of an Elusive Metastable Phase. METALS 2020. [DOI: 10.3390/met10020187] [Citation(s) in RCA: 39] [Impact Index Per Article: 9.8] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 01/06/2023]
Abstract
Austenitic stainless steels are employed in many industrial fields, due to their excellent corrosion resistance, easy formability and weldability. However, their low hardness, poor tribological properties and the possibility of localized corrosion in specific environments may limit their use. Conventional thermochemical surface treatments, such as nitriding or carburizing, are able to enhance surface hardness, but at the expense of corrosion resistance, owing to the formation of chromium-containing precipitates. An effective alternative is the so called low temperature treatments, which are performed with nitrogen- and/or carbon-containing media at temperatures, at which chromium mobility is low and the formation of precipitates is hindered. As a consequence, interstitial atoms are retained in solid solution in austenite, and a metastable supersaturated phase forms, named expanded austenite or S phase. Since the first studies, dating 1980s, the S phase has demonstrated to have high hardness and good corrosion resistance, but also other interesting properties and an elusive structure. In this review the main studies on the formation and characteristics of S phase are summarized and the results of the more recent research are also discussed. Together with mechanical, fatigue, tribological and corrosion resistance properties of this phase, electric and magnetic properties, wettability and biocompatibility are overviewed.
Collapse
|
7
|
Sarrafpour B, Boughton P, Farahani RM, Cox SC, Denyer G, Kelly E, Zoellner H. A method for investigating the cellular response to cyclic tension or compression in three-dimensional culture. J Mech Behav Biomed Mater 2018; 88:11-17. [PMID: 30118920 DOI: 10.1016/j.jmbbm.2018.08.006] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/19/2018] [Revised: 05/17/2018] [Accepted: 08/07/2018] [Indexed: 11/26/2022]
Abstract
We have an interest in the cellular response to mechanical stimuli, and here describe an in-vitro method to examine the response of cells cultured in a three-dimensional matrix to mechanical compressive and tensile stress. Synthetic aliphatic polyester scaffolds coated with 45S5 bioactive glass were seeded with human dental follicular cells (HDFC), and attached to well inserts and magnetic endplates in six well palates. Scaffolds were subjected to either cyclic 10% tensile deformation, or 8% compression, at 1 Hz and 2 Hz respectively for 6, 24 or 48 h, by uniaxial motion of magnetically-coupled endplates. It was possible to isolate high quality mRNA from cells in these scaffolds, as demonstrated by high RNA integrity numbers scores, and ability to perform meaningful cRNA microarray analysis, in which 669 and 727 genes were consistently upregulated, and 662 and 518 genes down regulated at all times studied under tensile and compressive loading conditions respectively. MetaCore analysis revealed the most regulated gene ontogenies under both loading conditions to be for: cytoskeletal remodelling; cell adhesion-chemokines and adhesion; cytoskeleton remodelling-TGF WNT and cytoskeletal remodelling pathways. We believe the method here described will be of value for analysis of the cellular response to cyclic loading.
Collapse
Affiliation(s)
- Babak Sarrafpour
- The University of Sydney, Faculty of Dentistry, Department of Oral Pathology and Oral Medicine, Cellular and Molecular Pathology Research Unit, Westmead Centre for Oral Health, Westmead Hospital, NSW 2145, Australia.
| | - Philip Boughton
- The University of Sydney, The Institute of Biomedical Engineering and Technology, Sydney, NSW 2006, Australia.
| | - Ramin M Farahani
- The University of Sydney, Faculty of Dentistry, Institute of Dental Research, Westmead Hospital, NSW 2145, Australia.
| | - Stephen C Cox
- The University of Sydney, Department of Oral Surgery, Westmead Centre for Oral Health, Westmead Hospital, Westmead, NSW, Australia.
| | - Gareth Denyer
- The University of Sydney, School of Molecular Bioscience, NSW 2006, Australia.
| | - Elizabeth Kelly
- The University of Sydney, Faculty of Dentistry, Department of Oral Pathology and Oral Medicine, Cellular and Molecular Pathology Research Unit, Westmead Centre for Oral Health, Westmead Hospital, NSW 2145, Australia.
| | - Hans Zoellner
- The University of Sydney, Faculty of Dentistry, Department of Oral Pathology and Oral Medicine, Cellular and Molecular Pathology Research Unit, Westmead Centre for Oral Health, Westmead Hospital, NSW 2145, Australia.
| |
Collapse
|
8
|
Dhawan U, Pan HA, Shie MJ, Chu YH, Huang GS, Chen PC, Chen WL. The Spatiotemporal Control of Osteoblast Cell Growth, Behavior, and Function Dictated by Nanostructured Stainless Steel Artificial Microenvironments. NANOSCALE RESEARCH LETTERS 2017; 12:86. [PMID: 28168610 PMCID: PMC5293702 DOI: 10.1186/s11671-016-1810-1] [Citation(s) in RCA: 9] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Figures] [Subscribe] [Scholar Register] [Received: 11/21/2016] [Accepted: 12/23/2016] [Indexed: 06/06/2023]
Abstract
The successful application of a nanostructured biomaterial as an implant is strongly determined by the nanotopography size triggering the ideal cell response. Here, nanoporous topography on 304L stainless steel substrates was engineered to identify the nanotopography size causing a transition in the cellular characteristics, and accordingly, the design of nanostructured stainless steel surface as orthopedic implants is proposed. A variety of nanopore diameters ranging from 100 to 220 nm were fabricated by one-step electrolysis process and collectively referred to as artificial microenvironments. Control over the nanopore diameter was achieved by varying bias voltage. MG63 osteoblasts were cultured on the nanoporous surfaces for different days. Immunofluorescence (IF) and scanning electron microscopy (SEM) were performed to compare the modulation in cell morphologies and characteristics. Osteoblasts displayed differential growth parameters and distinct transition in cell behavior after nanopore reached a certain diameter. Nanopores with 100-nm diameter promoted cell growth, focal adhesions, cell area, viability, vinculin-stained area, calcium mineralization, and alkaline phosphatase activity. The ability of these nanoporous substrates to differentially modulate the cell behavior and assist in identifying the transition step will be beneficial to biomedical engineers to develop superior implant geometries, triggering an ideal cell response at the cell-nanotopography interface.
Collapse
Affiliation(s)
- Udesh Dhawan
- Department of Materials Science and Engineering, National Chiao Tung University, 1001 University Road, Hsinchu, Taiwan, ROC
| | - Hsu-An Pan
- Department of Materials Science and Engineering, National Chiao Tung University, 1001 University Road, Hsinchu, Taiwan, ROC
| | - Meng-Je Shie
- Department of Materials Science and Engineering, National Chiao Tung University, 1001 University Road, Hsinchu, Taiwan, ROC
| | - Ying Hao Chu
- Department of Materials Science and Engineering, National Chiao Tung University, 1001 University Road, Hsinchu, Taiwan, ROC
| | - Guewha S. Huang
- Department of Materials Science and Engineering, National Chiao Tung University, 1001 University Road, Hsinchu, Taiwan, ROC
| | - Po-Chun Chen
- Institute of Materials Science and Engineering, National Taipei University of Technology, Section 3, Zhongxiao E Road, Taipei City, 106 Taiwan, ROC
| | - Wen Liang Chen
- Department of Biological Science and Technology, National Chiao Tung University, 1001 University Road, Hsinchu, 300 Taiwan, ROC
| |
Collapse
|
9
|
Anwar IB, Santoso A, Saputra E, Ismail R, Jamari J, Van der Heide E. Human Bone Marrow-Derived Mesenchymal Cell Reactions to 316L Stainless Steel: An in Vitro Study on Cell Viability and Interleukin-6 Expression. Adv Pharm Bull 2017; 7:335-338. [PMID: 28761837 PMCID: PMC5527249 DOI: 10.15171/apb.2017.040] [Citation(s) in RCA: 6] [Impact Index Per Article: 0.9] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/25/2017] [Revised: 06/11/2017] [Accepted: 06/12/2017] [Indexed: 11/29/2022] Open
Abstract
Purpose: Human bone marrow-derived mesenchymal cell (hBMC) reactions to 316L stainless steel (316L-SS) have never been evaluated. The objective of this study was to assess cell viability and interleukin-6 expression of hBMC cultures upon treatment with a 316L-SS implant.
Methods: A cytotoxicity analysis was conducted with a 3-(4,5-dimethylthiazol 2-yl)-2,5-diphenyltetrazolium (MTT) assay after a period of 24, 48 and 72 hours of incubation. Expression of interleukin-6 was measured using enzyme-linked immunosorbent assay (ELISA).
Results: Cell viability measurement was performed via IC50 formula. All treatment group showed a > 50 % cell viability with a range of 56,5 - 96,9 % at 24 hours, 51,8-77,3% at 48 hours and 70,1- 120 % at 72 hours. Interleukin-6 expression was downregulated subsequent to treatment with 316L-SS compared to the control group.
Conclusion: We found that 316L-SS did not exhibit toxicity towards hBMC culture.
Collapse
Affiliation(s)
- Iwan Budiwan Anwar
- Laboratory for Surface Technology and Tribology, Faculty of Engineering Technology, University of Twente Drienerloolaan 5, Postbox 217, 7500 AE, Enschede, The Netherlands.,Orthopaedic and Traumatology Department, Prof. Dr. R. Soeharso Orthopaedic Hospital, Jl. A. Yani Pabelan, Surakarta 57162, Indonesia
| | - Asep Santoso
- Orthopaedic and Traumatology Department, Prof. Dr. R. Soeharso Orthopaedic Hospital, Jl. A. Yani Pabelan, Surakarta 57162, Indonesia
| | - Eko Saputra
- Laboratory for Surface Technology and Tribology, Faculty of Engineering Technology, University of Twente Drienerloolaan 5, Postbox 217, 7500 AE, Enschede, The Netherlands.,Laboratory for Engineering Design and Tribology, Department of Mechanical Engineering, Diponegoro University, Jl. Prof. Soedharto, Tembalang, Semarang 50275, Indonesia
| | - Rifky Ismail
- Laboratory for Engineering Design and Tribology, Department of Mechanical Engineering, Diponegoro University, Jl. Prof. Soedharto, Tembalang, Semarang 50275, Indonesia
| | - J Jamari
- Laboratory for Engineering Design and Tribology, Department of Mechanical Engineering, Diponegoro University, Jl. Prof. Soedharto, Tembalang, Semarang 50275, Indonesia
| | - Emile Van der Heide
- Laboratory for Surface Technology and Tribology, Faculty of Engineering Technology, University of Twente Drienerloolaan 5, Postbox 217, 7500 AE, Enschede, The Netherlands
| |
Collapse
|
10
|
Cultures and co-cultures of human blood mononuclear cells and endothelial cells for the biocompatibility assessment of surface modified AISI 316L austenitic stainless steel. MATERIALS SCIENCE & ENGINEERING. C, MATERIALS FOR BIOLOGICAL APPLICATIONS 2016; 69:1081-91. [PMID: 27612806 DOI: 10.1016/j.msec.2016.08.010] [Citation(s) in RCA: 6] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Subscribe] [Scholar Register] [Received: 04/26/2016] [Revised: 06/30/2016] [Accepted: 08/03/2016] [Indexed: 11/20/2022]
Abstract
Samples of AISI 316L austenitic stainless steel were subjected either to grinding and polishing procedure, or to grinding and then low temperature glow-discharge nitriding treatment, or to grinding, nitriding and subsequently coating with collagen-I. Nitrided samples, even if only ground, show a higher corrosion resistance in PBS solution, in comparison with ground and polished AISI 316L. Biocompatibility was evaluated in vitro by incubating the samples with either peripheral blood mononuclear cells (PBMC) or human umbilical vein endothelial cells (HUVEC), tested separately or in co-culture. HUVEC-PBMC co-culture and co-incubation of HUVEC with PBMC culture medium, after the previous incubation of PBMC with metallic samples, allowed to determine whether the incubation of PBMC with the different samples might affect HUVEC behaviour. Many biological parameters were considered: cell proliferation, release of cytokines, matrix metalloproteinases (MMPs) and sICAM-1, gelatinolytic activity of MMPs, and ICAM-1 protein expression. Nitriding treatment, with or without collagen coating of the samples, is able to ameliorate some of the biological parameters taken into account. The obtained results point out that biocompatibility may be successfully tested in vitro, using cultures of normal human cells, as blood and endothelial cells, but more than one cell line should be used, separately or in co-culture, and different parameters should be determined, in particular those correlated with inflammatory phenomena.
Collapse
|
11
|
Stio M, Martinesi M, Treves C, Borgioli F. In vitro response of human peripheral blood mononuclear cells to AISI 316L austenitic stainless steel subjected to nitriding and collagen coating treatments. JOURNAL OF MATERIALS SCIENCE. MATERIALS IN MEDICINE 2015; 26:100. [PMID: 25655502 DOI: 10.1007/s10856-015-5446-y] [Citation(s) in RCA: 4] [Impact Index Per Article: 0.4] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 08/07/2014] [Accepted: 11/27/2014] [Indexed: 06/04/2023]
Abstract
Surface modification treatments can be used to improve the biocompatibility of austenitic stainless steels. In the present research two different modifications of AISI 316L stainless steel were considered, low temperature nitriding and collagen-I coating, applied as single treatment or in conjunction. Low temperature nitriding produced modified surface layers consisting mainly of S phase, which enhanced corrosion resistance in PBS solution. Biocompatibility was assessed using human peripheral blood mononuclear cells (PBMC) in culture. Proliferation, lactate dehydrogenase (LDH) levels, release of cytokines (TNF-α, IL-1β, IL-12, IL-10), secretion of metalloproteinase (MMP)-9 and its inhibitor TIMP-1, and the gelatinolytic activity of MMP-9 were determined. While the 48-h incubation of PBMC with all the sample types did not negatively influence cell proliferation, LDH and MMP-9 levels, suggesting therefore a good biocompatibility, the release of the pro-inflammatory cytokines was always remarkable when compared to that of control cells. However, in the presence of the nitrided and collagen coated samples, the release of the pro-inflammatory cytokine IL-1β decreased, while that of the anti-inflammatory cytokine IL-10 increased, in comparison with the untreated AISI 316L samples. Our results suggest that some biological parameters were ameliorated by these surface treatments of AISI 316L.
Collapse
Affiliation(s)
- Maria Stio
- Department of Biomedical, Experimental and Clinical Sciences 'Mario Serio', Section of Biochemical Sciences, University of Florence, Viale Morgagni 50, 50134, Florence, Italy
| | | | | | | |
Collapse
|
12
|
Liu X, Sun J. Potential proinflammatory effects of hydroxyapatite nanoparticles on endothelial cells in a monocyte-endothelial cell coculture model. Int J Nanomedicine 2014; 9:1261-73. [PMID: 24648726 PMCID: PMC3956627 DOI: 10.2147/ijn.s56298] [Citation(s) in RCA: 11] [Impact Index Per Article: 1.1] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/23/2022] Open
Abstract
Currently, synthetic hydroxyapatite nanoparticles (HANPs) are used in nanomedicine fields. The delivery of nanomedicine to the bloodstream exposes the cardiovascular system to a potential threat. However, the possible adverse cardiovascular effects of HANPs remain unclear. Current observations using coculture models of endothelial cells and monocytes with HANPs to mimic the complex physiological functionality of the vascular system demonstrate that monocytes could play an important role in the mechanisms of endothelium dysfunction induced by the exposure to HANPs. Our transmission electron microscopy analysis revealed that both monocytes and endothelial cells could take up HANPs. Moreover, our findings demonstrated that at a subcytotoxic dose, HANPs alone did not cause direct endothelial cell injury, but they did induce an indirect activation of endothelial cells, resulting in increased interleukin-6 production and elevated adhesion molecule expression after coculture with monocytes. The potential proinflammatory effect of HANPs is largely mediated by the release of soluble factors from the activated monocytes, leading to an inflammatory response of the endothelium, which is possibly dependent on p38/c-Jun N-terminal kinase, and nuclear factor-kappa B signaling activation. The use of in vitro monocyte–endothelial cell coculture models for the biocompatibility assessment of HANPs could reveal their potential proinflammatory effects on endothelial cells, suggesting that exposure to HANPs possibly increases the risk of cardiovascular disease.
Collapse
Affiliation(s)
- Xin Liu
- Shanghai Biomaterials Research and Testing Center, Shanghai Key Laboratory of Stomatology, Ninth People's Hospital, Shanghai Jiao Tong University School of Medicine, Shanghai, People's Republic of China
| | - Jiao Sun
- Shanghai Biomaterials Research and Testing Center, Shanghai Key Laboratory of Stomatology, Ninth People's Hospital, Shanghai Jiao Tong University School of Medicine, Shanghai, People's Republic of China
| |
Collapse
|
13
|
Conti MC, Karl A, Wismayer PS, Buhagiar J. Biocompatibility and characterization of a Kolsterised(®) medical grade cobalt-chromium-molybdenum alloy. BIOMATTER 2014; 4:e27713. [PMID: 24451266 DOI: 10.4161/biom.27713] [Citation(s) in RCA: 7] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 12/12/2022]
Abstract
High failure rates of cobalt-chromium-molybdenum (Co-Cr-Mo) metal-on-metal hip prosthesis were reported by various authors, probably due to the alloy's limited hardness and tribological properties. This thus caused the popularity of the alloy in metal-on-metal hip replacements to decrease due to its poor wear properties when compared with other systems such as ceramic-on-ceramic. S-phase surface engineering has become an industry standard when citing surface hardening of austenitic stainless steels. This hardening process allows the austenitic stainless steel to retain its corrosion resistance, while at the same time also improving its hardness and wear resistance. By coupling S-phase surface engineering, using the proprietary Kolsterising(®) treatment from Bodycote Hardiff GmbH, that is currently being used mainly on stainless steel, with Co-Cr-Mo alloys, an improvement in hardness and tribological characteristics is predicted. The objective of this paper is to analyze the biocompatibility of a Kolsterised(®) Co-Cr-Mo alloy, and to characterize the material surface in order to show the advantages gained by using the Kolsterised(®) material relative to the original untreated alloy, and other materials. This work has been performed on 3 fronts including; Material characterization, "In-vitro" corrosion testing, and Biological testing conforming to BS EN ISO 10993-18:2009 - Biological evaluation of medical devices. Using these techniques, the Kolsterised(®) cobalt-chromium-molybdenum alloys were found to have good biocompatibility and an augmented corrosion resistance when compared with the untreated alloy. The Kolsterised(®) samples also showed a 150% increase in surface hardness over the untreated material thus predicting better wear properties.
Collapse
Affiliation(s)
| | | | | | - Joseph Buhagiar
- Department of Metallurgy and Materials Engineering; University of Malta; Msida, Malta
| |
Collapse
|
14
|
Martinesi M, Stio M, Treves C, Borgioli F. Biocompatibility studies of low temperature nitrided and collagen-I coated AISI 316L austenitic stainless steel. JOURNAL OF MATERIALS SCIENCE. MATERIALS IN MEDICINE 2013; 24:1501-1513. [PMID: 23471501 DOI: 10.1007/s10856-013-4902-9] [Citation(s) in RCA: 6] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 10/02/2012] [Accepted: 02/23/2013] [Indexed: 06/01/2023]
Abstract
The biocompatibility of austenitic stainless steels can be improved by means of surface engineering techniques. In the present research it was investigated if low temperature nitrided AISI 316L austenitic stainless steel may be a suitable substrate for bioactive protein coating consisting of collagen-I. The biocompatibility of surface modified alloy was studied using as experimental model endothelial cells (human umbilical vein endothelial cells) in culture. Low temperature nitriding produces modified surface layers consisting mainly of S phase, the supersaturated interstitial solid solution of nitrogen in the austenite lattice, which allows to enhance surface microhardness and corrosion resistance in PBS solution. The nitriding treatment seems to promote the coating with collagen-I, without chemical coupling agents, in respect of the untreated alloy. For biocompatibility studies, proliferation, lactate dehydrogenase levels and secretion of two metalloproteinases (MMP-2 and MMP-9) were determined. Experimental results suggest that the collagen protection may be favourable for endothelial cell proliferation and for the control of MMP-2 release.
Collapse
Affiliation(s)
- M Martinesi
- Department of Biomedical, Experimental and Clinical Sciences, University of Florence, Viale Morgagni 50, 50134 Florence, Italy
| | | | | | | |
Collapse
|
15
|
Le VQ, Cochis A, Rimondini L, Pourroy G, Stanic V, Palkowski H, Carradò A. Biomimetic calcium–phosphates produced by an auto-catalytic route on stainless steel 316L and bio-inert polyolefin. RSC Adv 2013. [DOI: 10.1039/c3ra23385e] [Citation(s) in RCA: 11] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/21/2022] Open
|
16
|
Buhagiar J, Bell T, Sammons R, Dong H. Evaluation of the biocompatibility of S-phase layers on medical grade austenitic stainless steels. JOURNAL OF MATERIALS SCIENCE. MATERIALS IN MEDICINE 2011; 22:1269-1278. [PMID: 21437638 DOI: 10.1007/s10856-011-4298-3] [Citation(s) in RCA: 7] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 10/13/2010] [Accepted: 03/16/2011] [Indexed: 05/30/2023]
Abstract
S-phase surface layers were formed in AISI 316LVM (ASTM F138) and High-N (ASTM F1586) medical grade austenitic stainless steels by plasma surface alloying with nitrogen (at 430°C), carbon (at 500°C) and both carbon and nitrogen (at 430°C). The presence of the S-phase was confirmed by microscopy, hardness testing, depth-profile analysis of chemical composition and X-ray Diffraction. Attachment and proliferation of mouse osteoblast MC3T3-E1 cells were tested on S-phase and untreated controls and the results demonstrated that all the S-phase layers formed were biocompatible under the conditions used. Cells adhered equally well to all samples but proliferation was enhanced on the treated materials.
Collapse
Affiliation(s)
- Joseph Buhagiar
- School of Metallurgy and Materials, The University of Birmingham, Birmingham, B15 2TT, UK.
| | | | | | | |
Collapse
|
17
|
Hwang HS, Yang EJ, Ryu YH, Lee MS, Choi SM. Electrochemical corrosion of STS304 acupuncture needles by electrical stimulation. J Acupunct Meridian Stud 2010; 3:89-94. [PMID: 20633521 DOI: 10.1016/s2005-2901(10)60017-9] [Citation(s) in RCA: 9] [Impact Index Per Article: 0.6] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/12/2009] [Accepted: 03/02/2010] [Indexed: 01/01/2023] Open
Abstract
We present the first investigation of electrical corrosion in acupuncture needles after electrical stimulation. Using scanning electron microscopy, we observed the occurrence of electrochemical corrosion on the surface of stainless steel 304 acupuncture needles after electrical stimulation in the tibial muscles of rats. Biphasic pulse electrical stimuli with 10-Hz frequency, 1-mA intensity and 1-ms pulse width were applied to the needles. The terminal deoxynucleotidyl transferase-mediated dUTP-biotin nick end labeling (TUNEL) method labels fragmented DNA. Positive staining using this test indicates apoptotic cells in electrically stimulated tissues. The risk of electrical corrosion was found to be less in bipolar, short-duration, low-current or voltage and short-period stimulation than in monopolar, long-duration, high-current or voltage and long-period stimulation. Evaluation with a scanning electron microscope revealed that electrical stimulation can increase the electrical corrosion of stainless steel 304 acupuncture needles. In biocompatibility studies of stainless steel 304 acupuncture needles for electrical stimulation, TUNEL-positive cells were detected in the tibial muscle within 5 days after electrical stimulation. The results of this study demonstrate that the corrosion products of stainless steel 304 acupuncture needles might affect the post-electrical stimulation tissue response.
Collapse
Affiliation(s)
- Hye Suk Hwang
- Division of Standard Research, Korea Institute of Oriental Medicine, Daejeon, Korea
| | | | | | | | | |
Collapse
|
18
|
Liu X, Xue Y, Sun J. Indirect induction of endothelial cell injury by PU- or PTFE-mediated activation of monocytes. JOURNAL OF BIOMATERIALS SCIENCE-POLYMER EDITION 2010; 21:1783-97. [PMID: 20557688 DOI: 10.1163/092050609x12567180627536] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.1] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 02/04/2023]
Abstract
Polyurethanes (PUs) and polytetrafluoroethylene (PTFE) are widely used for making cardiovascular devices, but thrombus formation on the surfaces of these devices is inevitable. Since endothelial injury can lead to thrombosis, most of the studies on PUs or PTFE focused on their damage to endothelial cells. However, few studies have attempted to clarify whether the use of foreign objects as biomaterials can cause endothelial injury by activating the innate immune system. In this study, we aimed to investigate the roles of PU- or PTFE-stimulated immune cells in endothelial-cell injury. First, monocytes (THP-1 cells) were stimulated with PU or PTFE for 24 h and, subsequently, human umbilical vein endothelial cells (HUVECs) were treated with the supernatants of the stimulated cells for 24 h. We measured the generation of intracellular reactive oxygen species (ROS) from THP-1 cells treated with PU and PTFE for 24 h, meanwhile hydrogen dioxide (H(2)O(2)), tumor necrosis factor (TNF)-α and interleukin (IL)-1β in the supernatants were also detected. Then, we assessed the apoptosis rate of the HUVECs and determined the expression of NO, inducible nitric oxide synthase (iNOS), and apoptosis-related proteins (p53, Bax, Bcl-2) in the HUVECs. The results showed that large amounts of ROS and low levels of pro-inflammatory cytokines (TNF-α and IL-1β) were produced by the stimulated THP-1 cells. After culturing with the supernatants of the PU- or PTFE-stimulated THP-1 cells, the apoptosis rate, NO production and expression of iNOS, p53 and Bax in the HUVECs were up-regulated, while Bcl-2 expression was down-regulated. In conclusion, the release of ROS by PU- or PTFE-treated THP-1 cells may induce iNOS expression and cause apoptosis in HUVECs via the p53, Bax and Bcl-2 proteins. These data provide the interesting finding that endothelial injury in the process of biomaterial-induced thrombosis can be initiated through the release of soluble mediators by monocytes.
Collapse
Affiliation(s)
- Xin Liu
- Shanghai Biomaterials Research & Testing Center, Shanghai Ninth People's Hospital, Shanghai Jiaotong University School of Medicine, Shanghai, P R China
| | | | | |
Collapse
|
19
|
Treves C, Martinesi M, Stio M, Gutiérrez A, Jiménez JA, López MF. In vitro biocompatibility evaluation of surface-modified titanium alloys. J Biomed Mater Res A 2010; 92:1623-34. [PMID: 19437430 DOI: 10.1002/jbm.a.32507] [Citation(s) in RCA: 11] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/12/2022]
Abstract
The present work is aimed to evaluate the effects of a surface modification process on the biocompatibility of three vanadium-free titanium alloys with biomedical applications interest. Chemical composition of alloys investigated, in weight %, were Ti-7Nb-6Al, Ti-13Nb-13Zr, and Ti-15Zr-4Nb. An easy and economic method intended to improve the biocompatibiblity of these materials consists in a simple thermal treatment at high temperature, 750 degrees C, in air for different times. The significance of modification of the surface properties to the biological response was studied putting in contact both untreated and thermally treated alloys with human cells in culture, Human Umbilical Vein Endothelial Cells (HUVEC) and Human Peripheral Blood Mononuclear Cells (PBMC). The TNF-alpha release data indicate that thermal treatment improves the biological response of the alloys. The notable enhancement of the surface roughness upon oxidation could be related with the observed reduction of the TNF-alpha levels for treated alloys. A different behavior of the two cell lines may be observed, when adhesion molecules (ICAM-1 and VCAM-1 in HUVEC, ICAM-1, and LFA-1 in PBMC) were determined, PBMC being more sensitive than HUVEC to the contact with the samples. The data also distinguish surface composition and corrosion resistance as significant parameters for the biological response.
Collapse
Affiliation(s)
- Cristina Treves
- Department of Biochemical Sciences of the University of Florence, Florence, Italy.
| | | | | | | | | | | |
Collapse
|