1
|
Turek A, Rech J, Borecka A, Wilińska J, Kobielarz M, Janeczek H, Kasperczyk J. The Role of the Mechanical, Structural, and Thermal Properties of Poly(l-lactide- co-glycolide- co-trimethylene carbonate) in the Development of Rods with Aripiprazole. Polymers (Basel) 2021; 13:polym13203556. [PMID: 34685315 PMCID: PMC8539605 DOI: 10.3390/polym13203556] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/04/2021] [Revised: 09/29/2021] [Accepted: 10/01/2021] [Indexed: 11/16/2022] Open
Abstract
In this work, we aimed to determine the role of the mechanical, structural, and thermal properties of poly(l-lactide-co-glycolide-co-trimethylene carbonate) (P(l-LA:GA:TMC)) with shape memory in the formulation of implantable and biodegradable rods with aripiprazole (ARP). Hot melt extrusion (HME) and electron beam (EB) irradiation were applied in the formulation process of blank rods and rods with ARP. Rod degradation was carried out in a PBS solution. HPLC; NMR; DSC; compression and tensile tests; molecular weight (Mn); water uptake (WU); and weight loss (WL) analyses; and SEM were used in this study. HME and EB irradiation did not influence the structure of ARP. The mechanical tests indicated that the rods may be safely implanted using a pre-filled syringe. During degradation, no unfavorable changes in terpolymer content were observed. A decrease in the glass transition temperature and the Mn, and an increase in the WU and the WL were revealed. The loading of ARP and EB irradiation induced earlier pore formation and more intense WU and WL changes. ARP was released in a tri-phasic model with the lag phase; therefore, the proposed formulation may be administered as a delayed-release system. EB irradiation was found to accelerate ARP release.
Collapse
Affiliation(s)
- Artur Turek
- Chair and Department of Biopharmacy, Faculty of Pharmaceutical Sciences in Sosnowiec, Medical University of Silesia, Katowice, Jedności 8, 41-200 Sosnowiec, Poland; (J.W.); (J.K.)
- Correspondence: or ; Tel.: +48-32-364-12-17; Fax: +48-32-364-12-66
| | - Jakub Rech
- Department of Biotechnology and Genetic Engineering, Faculty of Pharmaceutical Sciences in Sosnowiec, Medical University of Silesia, Katowice, Jedności 8, 41-200 Sosnowiec, Poland;
| | - Aleksandra Borecka
- Centre of Polymer and Carbon Materials, Polish Academy of Sciences, M. Curie-Skłodowskiej 34, 41-819 Zabrze, Poland; (A.B.); (H.J.)
| | - Justyna Wilińska
- Chair and Department of Biopharmacy, Faculty of Pharmaceutical Sciences in Sosnowiec, Medical University of Silesia, Katowice, Jedności 8, 41-200 Sosnowiec, Poland; (J.W.); (J.K.)
| | - Magdalena Kobielarz
- Department of Mechanics, Materials and Biomedical Engineering, Faculty of Mechanical Engineering, Wrocław University of Science and Technology, Wybrzeże Wyspiańskiego 27, 50-370 Wroclaw, Poland;
| | - Henryk Janeczek
- Centre of Polymer and Carbon Materials, Polish Academy of Sciences, M. Curie-Skłodowskiej 34, 41-819 Zabrze, Poland; (A.B.); (H.J.)
| | - Janusz Kasperczyk
- Chair and Department of Biopharmacy, Faculty of Pharmaceutical Sciences in Sosnowiec, Medical University of Silesia, Katowice, Jedności 8, 41-200 Sosnowiec, Poland; (J.W.); (J.K.)
- Centre of Polymer and Carbon Materials, Polish Academy of Sciences, M. Curie-Skłodowskiej 34, 41-819 Zabrze, Poland; (A.B.); (H.J.)
| |
Collapse
|
2
|
Lee WL, Loo SCJ. Revolutionizing drug delivery through biodegradable multilayered particles. J Drug Target 2012; 20:633-47. [PMID: 22738195 DOI: 10.3109/1061186x.2012.702772] [Citation(s) in RCA: 15] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/13/2022]
Abstract
Modern drug discovery technologies are discovering more and more potent therapeutic agents with narrow therapeutic windows, thus necessitating the improvement of current particulate drug delivery systems. Conventional single-layered polymeric particles have limited control over drug release profiles, including burst release, the inability to provide zero-order, pulsatile, time-delayed release and controlled release of multiple drugs. In an attempt to better control drug release kinetics, the development of multilayered microparticles has been introduced. In this review, we give an overview of the fabrication and characterization techniques of multilayered polymeric microparticles. We also focus on the one-step solvent evaporation technique, and the key process parameters in this technique that affect the formation of microparticle configurations. In addition, the benefits and challenges of multilayered microparticulate system for drug delivery were discussed. This review intends to portray how distinctive structural attributes and degradation behaviors of multilayered microparticles can be exploited to fine-tune drug release profiles and kinetics.
Collapse
Affiliation(s)
- Wei Li Lee
- School of Materials Science and Engineering, Nanyang Technological University, 50 Nanyang Ave., Singapore, Singapore
| | | |
Collapse
|
3
|
Steele TWJ, Huang CL, Kumar S, Widjaja E, Chiang Boey FY, Loo JSC, Venkatraman SS. High-throughput screening of PLGA thin films utilizing hydrophobic fluorescent dyes for hydrophobic drug compounds. J Pharm Sci 2011; 100:4317-29. [PMID: 21607953 DOI: 10.1002/jps.22625] [Citation(s) in RCA: 21] [Impact Index Per Article: 1.6] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/28/2011] [Revised: 04/02/2011] [Accepted: 04/26/2011] [Indexed: 01/06/2023]
Abstract
Hydrophobic, antirestenotic drugs such as paclitaxel (PCTX) and rapamycin are often incorporated into thin film coatings for local delivery using implantable medical devices and polymers such as drug-eluting stents and balloons. Selecting the optimum coating formulation through screening the release profile of these drugs in thin films is time consuming and labor intensive. We describe here a high-throughput assay utilizing three model hydrophobic fluorescent compounds: fluorescein diacetate (FDAc), coumarin-6, and rhodamine 6G that were incorporated into poly(d,l-lactide-co-glycolide) (PLGA) and PLGA-polyethylene glycol films. Raman microscopy determined the hydrophobic fluorescent dye distribution within the PLGA thin films in comparison with that of PCTX. Their subsequent release was screened in a high-throughput assay and directly compared with HPLC quantification of PCTX release. It was observed that PCTX controlled-release kinetics could be mimicked by a hydrophobic dye that had similar octanol-water partition coefficient values and homogeneous dissolution in a PLGA matrix as the drug. In particular, FDAc was found to be the optimal hydrophobic dye at modeling the burst release as well as the total amount of PCTX released over a period of 30 days.
Collapse
Affiliation(s)
- Terry W J Steele
- Materials and Science Engineering, Division of Materials Technology, Nanyang Technological University, Singapore 639798
| | | | | | | | | | | | | |
Collapse
|
4
|
Steele TWJ, Huang CL, Widjaja E, Boey FYC, Loo JSC, Venkatraman SS. The effect of polyethylene glycol structure on paclitaxel drug release and mechanical properties of PLGA thin films. Acta Biomater 2011; 7:1973-83. [PMID: 21300188 DOI: 10.1016/j.actbio.2011.02.002] [Citation(s) in RCA: 52] [Impact Index Per Article: 4.0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/27/2010] [Revised: 12/21/2010] [Accepted: 02/02/2011] [Indexed: 01/28/2023]
Abstract
Thin films of poly(lactic acid-co-glycolic acid) (PLGA) incorporating paclitaxel typically have slow release rates of paclitaxel of the order of 1 μg day(-1) cm(-2). For implementation as medical devices a range of zero order release rates (i.e. 1-15 μg day(-1) cm(-2)) is desirable for different tissues and pathologies. Eight and 35 kDa molecular weight polyethylene glycol (PEG) was incorporated at 15%, 25% and 50% weight ratios into PLGA containing 10 wt.% paclitaxel. The mechanical properties were assessed for potential use as medical implants and the rates of release of paclitaxel were quantified as per cent release and the more clinically useful rate of release in μg day(-1) cm(-2). Paclitaxel quantitation was correlated with the release of PEG from PLGA, to further understand its role in paclitaxel/PLGA release modulation. PEG release was found to correlate with paclitaxel release and the level of crystallinity of the PEG in the PLGA film, as measured by Raman spectrometry. This supports the concept of using a phase separating, partitioning compound to increase the release rates of hydrophobic drugs such as paclitaxel from PLGA films, where paclitaxel is normally homogeneously distributed/dissolved. Two formulations are promising for medical device thin films, when optimized for tensile strength, elongation, and drug release. For slow rates of paclitaxel release an average of 3.8 μg day(-1) cm(-2) using 15% 35k PEG for >30 days was achieved, while a high rate of drug release of 12 μg day(-1) cm(-2) was maintained using 25% 8 kDa PEG for up to 12 days.
Collapse
Affiliation(s)
- Terry W J Steele
- Nanyang Technological University, Materials and Science Engineering, Division of Materials Technology, Singapore, Singapore
| | | | | | | | | | | |
Collapse
|
5
|
XIONG S, Zhao X, Heng BC, Ng KW, Loo JSC. Cellular uptake of Poly-(D,L-lactide-co-glycolide) (PLGA) nanoparticles synthesized through solvent emulsion evaporation and nanoprecipitation method. Biotechnol J 2011; 6:501-8. [DOI: 10.1002/biot.201000351] [Citation(s) in RCA: 49] [Impact Index Per Article: 3.8] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/15/2010] [Revised: 11/27/2010] [Accepted: 11/30/2010] [Indexed: 12/17/2022]
|
6
|
Surface modification of poly(l-lactic acid) with biomolecules to promote endothelialization. Biointerphases 2010; 5:FA32-40. [DOI: 10.1116/1.3467508] [Citation(s) in RCA: 29] [Impact Index Per Article: 2.1] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/17/2022] Open
|
7
|
Loo SCJ, Tan ZYS, Chow YJ, Lin SLI. Drug Release From Irradiated PLGA and PLLA Multi-Layered Films. J Pharm Sci 2010; 99:3060-71. [DOI: 10.1002/jps.22079] [Citation(s) in RCA: 45] [Impact Index Per Article: 3.2] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/12/2022]
|
8
|
Phong L, Han ESC, Xiong S, Pan J, Loo SCJ. Properties and hydrolysis of PLGA and PLLA cross-linked with electron beam radiation. Polym Degrad Stab 2010. [DOI: 10.1016/j.polymdegradstab.2010.02.012] [Citation(s) in RCA: 18] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/29/2022]
|
9
|
Lee WL, Hong M, Widjaja E, Loo SCJ. Formation and Degradation of Biodegradable Triple-Layered Microparticles. Macromol Rapid Commun 2010; 31:1193-200. [DOI: 10.1002/marc.200900811] [Citation(s) in RCA: 16] [Impact Index Per Article: 1.1] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/11/2009] [Revised: 12/30/2009] [Indexed: 11/08/2022]
|
10
|
Tan HY, Widjaja E, Boey F, Loo SCJ. Spectroscopy techniques for analyzing the hydrolysis of PLGA and PLLA. J Biomed Mater Res B Appl Biomater 2009; 91:433-40. [DOI: 10.1002/jbm.b.31419] [Citation(s) in RCA: 30] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/11/2022]
|
11
|
|