Aleong AM, Berlin A, Borg J, Helou J, Beiki-Ardakani A, Rink A, Raman S, Chung P, Weersink RA. Rapid multi-catheter segmentation for magnetic resonance image-guided catheter-based interventions. Med Phys 2024. [PMID: 38713919 DOI: 10.1002/mp.17117] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/18/2023] [Revised: 04/02/2024] [Accepted: 04/18/2024] [Indexed: 05/09/2024] Open
Abstract
BACKGROUND Magnetic resonance imaging (MRI) is the gold standard for delineating cancerous lesions in soft tissue. Catheter-based interventions require the accurate placement of multiple long, flexible catheters at the target site. The manual segmentation of catheters in MR images is a challenging and time-consuming task. There is a need for automated catheter segmentation to improve the efficiency of MR-guided procedures. PURPOSE To develop and assess a machine learning algorithm for the detection of multiple catheters in magnetic resonance images used during catheter-based interventions. METHODS In this work, a 3D U-Net was trained to retrospectively segment catheters in scans acquired during clinical MR-guided high dose rate (HDR) prostate brachytherapy cases. To assess confidence in segmentation, multiple AI models were trained. On clinical test cases, average segmentation results were used to plan the brachytherapy delivery. Dosimetric parameters were compared to the original clinical plan. Data was obtained from 35 patients who underwent HDR prostate brachytherapy for focal disease with a total of 214 image volumes. 185 image volumes from 30 patients were used for training using a five-fold cross validation split to divide the data for training and validation. To generate confidence measures of segmentation accuracy, five trained models were generated. The remaining five patients (29 volumes) were used to test the performance of the trained model by comparison to manual segmentations of three independent observers and assessment of dosimetric impact on the final clinical brachytherapy plans. RESULTS The network successfully identified 95% of catheters in the test set at a rate of 0.89 s per volume. The multi-model method identified the small number of cases where AI segmentation of individual catheters was poor, flagging the need for user input. AI-based segmentation performed as well as segmentations by independent observers. Plan dosimetry using AI-segmented catheters was comparable to the original plan. CONCLUSION The vast majority of catheters were accurately identified by AI segmentation, with minimal impact on plan outcomes. The use of multiple AI models provided confidence in the segmentation accuracy and identified catheter segmentations that required further manual assessment. Real-time AI catheter segmentation can be used during MR-guided insertions to assess deflections and for rapid planning of prostate brachytherapy.
Collapse
Affiliation(s)
- Amanda M Aleong
- Institute of Biomedical Engineering, University of Toronto, Toronto, Ontario, Canada
| | - Alejandro Berlin
- Department of Radiation Medicine, Princess Margaret Cancer Centre, Toronto, Ontario, Canada
- Department of Radiation Oncology, University of Toronto, Toronto, Ontario, Canada
| | - Jette Borg
- Department of Radiation Medicine, Princess Margaret Cancer Centre, Toronto, Ontario, Canada
- Department of Radiation Oncology, University of Toronto, Toronto, Ontario, Canada
| | - Joelle Helou
- Department of Radiation Medicine, Princess Margaret Cancer Centre, Toronto, Ontario, Canada
- Department of Radiation Oncology, University of Toronto, Toronto, Ontario, Canada
| | - Akbar Beiki-Ardakani
- Department of Radiation Medicine, Princess Margaret Cancer Centre, Toronto, Ontario, Canada
| | - Alexandra Rink
- Department of Radiation Medicine, Princess Margaret Cancer Centre, Toronto, Ontario, Canada
- Department of Radiation Oncology, University of Toronto, Toronto, Ontario, Canada
- Department of Medical Biophysics, University of Toronto, Toronto, Ontario, Canada
| | - Srinivas Raman
- Department of Radiation Medicine, Princess Margaret Cancer Centre, Toronto, Ontario, Canada
- Department of Radiation Oncology, University of Toronto, Toronto, Ontario, Canada
| | - Peter Chung
- Department of Radiation Medicine, Princess Margaret Cancer Centre, Toronto, Ontario, Canada
- Department of Radiation Oncology, University of Toronto, Toronto, Ontario, Canada
| | - Robert A Weersink
- Institute of Biomedical Engineering, University of Toronto, Toronto, Ontario, Canada
- Department of Radiation Medicine, Princess Margaret Cancer Centre, Toronto, Ontario, Canada
- Department of Radiation Oncology, University of Toronto, Toronto, Ontario, Canada
- Department of Medical Biophysics, University of Toronto, Toronto, Ontario, Canada
| |
Collapse
|
2
|
Knull E, Park CKS, Bax J, Tessier D, Fenster A. Toward mechatronic MRI-guided focal laser ablation of the prostate: Robust registration for improved needle delivery. Med Phys 2023; 50:1259-1273. [PMID: 36583505 DOI: 10.1002/mp.16190] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/26/2022] [Revised: 12/04/2022] [Accepted: 12/11/2022] [Indexed: 12/31/2022] Open
Abstract
BACKGROUND Multiparametric MRI (mpMRI) is an effective tool for detecting and staging prostate cancer (PCa), guiding interventional therapy, and monitoring PCa treatment outcomes. MRI-guided focal laser ablation (FLA) therapy is an alternative, minimally invasive treatment method to conventional therapies, which has been demonstrated to control low-grade, localized PCa while preserving patient quality of life. The therapeutic success of FLA depends on the accurate placement of needles for adequate delivery of ablative energy to the target lesion. We previously developed an MR-compatible mechatronic system for prostate FLA needle guidance and validated its performance in open-air and clinical 3T in-bore experiments using virtual targets. PURPOSE To develop a robust MRI-to-mechatronic system registration method and evaluate its in-bore MR-guided needle delivery accuracy in tissue-mimicking prostate phantoms. METHODS The improved registration multifiducial assembly houses thirty-six aqueous gadolinium-filled spheres distributed over a 7.3 × 7.3 × 5.2 cm volume. MRI-guided needle guidance accuracy was quantified in agar-based tissue-mimicking prostate phantoms on trajectories (N = 44) to virtual targets covering the mechatronic system's range of motion. 3T gradient-echo recalled (GRE) MRI images were acquired after needle insertions to each target, and the air-filled needle tracks were segmented. Needle guidance error was measured as the shortest Euclidean distance between the target point and the segmented needle trajectory, and angular error was measured as the angle between the targeted trajectory and the segmented needle trajectory. These measurements were made using both the previously designed four-sphere registration fiducial assembly on trajectories (N = 7) and compared with the improved multifiducial assembly using a Mann-Whitney U test. RESULTS The median needle guidance error of the system using the improved registration fiducial assembly at a depth of 10 cm was 1.02 mm with an interquartile range (IQR) of 0.42-2.94 mm. The upper limit of the one-sided 95% prediction interval of needle guidance error was 4.13 mm. The median (IQR) angular error was 0.0097 rad (0.0057-0.015 rad) with a one-sided 95% prediction interval upper limit of 0.022 rad. The median (IQR) positioning error using the previous four-sphere registration fiducial assembly was 1.87 mm (1.77-2.14 mm). This was found to be significantly different (p = 0.0012) from the median (IQR) positioning error of 0.28 mm (0.14-0.95 mm) using the new registration fiducial assembly on the same trajectories. No significant difference was detected between the medians of the angular errors (p = 0.26). CONCLUSION This is the first study presenting an improved registration method and validation in tissue-mimicking phantoms of our remotely actuated MR-compatible mechatronic system for delivery of prostate FLA needles. Accounting for the effects of needle deflection, the system was demonstrated to be capable of needle delivery with an error of 4.13 mm or less in 95% of cases under ideal conditions, which is a statistically significant improvement over the previous method. The system will next be validated in a clinical setting.
Collapse
Affiliation(s)
- Eric Knull
- Faculty of Engineering, School of Biomedical Engineering, Western University, London, Ontario, Canada
- Robarts Research Institute, Western University, London, Ontario, Canada
| | - Claire Keun Sun Park
- Robarts Research Institute, Western University, London, Ontario, Canada
- Department of Medical Biophysics, Schulich School of Medicine and Dentistry, Western University, London, Ontario, Canada
| | - Jeffrey Bax
- Robarts Research Institute, Western University, London, Ontario, Canada
| | - David Tessier
- Robarts Research Institute, Western University, London, Ontario, Canada
| | - Aaron Fenster
- Faculty of Engineering, School of Biomedical Engineering, Western University, London, Ontario, Canada
- Robarts Research Institute, Western University, London, Ontario, Canada
- Department of Medical Biophysics, Schulich School of Medicine and Dentistry, Western University, London, Ontario, Canada
| |
Collapse
|
3
|
Knull E, Bax JS, Park CKS, Tessier D, Fenster A. Design and validation of an MRI-compatible mechatronic system for needle delivery to localized prostate cancer. Med Phys 2021; 48:5283-5299. [PMID: 34131933 DOI: 10.1002/mp.15050] [Citation(s) in RCA: 3] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/21/2021] [Revised: 05/18/2021] [Accepted: 06/03/2021] [Indexed: 11/05/2022] Open
Abstract
PURPOSE Prostate cancer is the most common non-cutaneous cancer among men in the United States and is the second leading cause of cancer death in American men. (Siegel et al. [2019] CA: A Cancer J Clin.69(1):7-34.) Focal laser ablation (FLA) has the potential to control small tumors while preserving urinary and erectile function by leaving the neurovascular bundles and urethral sphincters intact. Accurate needle guidance is critical to the success of FLA. Multiparametric magnetic resonance images (mpMRI) can be used to identify targets, guide needles, and assess treatment outcomes. The purpose of this work was to design and evaluate the accuracy of an MR-compatible mechatronic system for in-bore transperineal guidance of FLA ablation needles to localized lesions in the prostate. METHODS The mechatronic system was constructed entirely of non-ferromagnetic materials, with actuation controlled by piezoelectric motors and optical encoders. The needle guide hangs between independent front and rear two-link arms, which allows for horizontal and vertical translation as well as pitch and yaw rotation of the guide with a 6.0 cm range of motion in each direction. Needles are inserted manually through a chosen hole in the guide, which has been aligned with the target in the prostate. Open-air positioning error was evaluated using an optical tracking system (0.25 mm RMS accuracy) to measure 125 trajectories in free space. Correction of systematic bias in the system was performed using 85 of the trajectories, and the remaining 40 were used to estimate the residual error. The error was calculated as the horizontal and vertical displacement between the axis of the desired and measured trajectories at a typical needle insertion depth of 10 cm. MR-compatibility was evaluated using a grid phantom to assess image degradation due to the presence of the system, and induced force, heating, and electrical interference in the system were assessed qualitatively. In-bore positioning error was evaluated on 25 trajectories. RESULTS Open-air mean positioning error at the needle tip was 0.80 ± 0.36 mm with a one-sided 95% confidence interval of 1.40 mm. The mean deviation of needle trajectories from the planned direction was 0.14 ± 0.06∘ . In the MR bore, the mean positioning error at the needle tip was 2.11 ± 1.05 mm with a one-sided 95% prediction interval of 3.84 mm. The mean angular error was 0.49 ± 0.26∘ . The system was found to be compatible with the MR environment under the specified gradient-echo sequence parameters used in this study. CONCLUSION A complete system for delivering needles to localized prostate tumors was developed and described in this work, and its compatibility with the MR environment was demonstrated. In-bore MRI positioning error was sufficiently small for targeting small localized prostate tumors.
Collapse
Affiliation(s)
- Eric Knull
- School of Biomedical Engineering, Faculty of Engineering, Western University, London, Ontario, Canada.,Robarts Research Institute, Western University, London, Ontario, Canada
| | - Jeffrey Scott Bax
- Robarts Research Institute, Western University, London, Ontario, Canada
| | - Claire Keun Sun Park
- Robarts Research Institute, Western University, London, Ontario, Canada.,Department of Medical Biophysics, Schulich School of Medicine and Dentistry, Western University, London, Ontario, Canada
| | - David Tessier
- Robarts Research Institute, Western University, London, Ontario, Canada
| | - Aaron Fenster
- School of Biomedical Engineering, Faculty of Engineering, Western University, London, Ontario, Canada.,Robarts Research Institute, Western University, London, Ontario, Canada.,Department of Medical Biophysics, Schulich School of Medicine and Dentistry, Western University, London, Ontario, Canada
| |
Collapse
|
4
|
Knull E, Oto A, Eggener S, Tessier D, Guneyli S, Chatterjee A, Fenster A. Evaluation of tumor coverage after MR-guided prostate focal laser ablation therapy. Med Phys 2018; 46:800-810. [PMID: 30447155 DOI: 10.1002/mp.13292] [Citation(s) in RCA: 6] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/29/2018] [Revised: 11/05/2018] [Accepted: 11/05/2018] [Indexed: 11/09/2022] Open
Abstract
PURPOSE Prostate cancer is the most common noncutaneous cancer among men in the USA. Focal laser thermal ablation (FLA) has the potential to control small tumors while preserving urinary and erectile function by leaving the neurovascular bundles and urethral sphincters intact. Accurate needle guidance is critical to the success of FLA. Multiparametric magnetic resonance images (mpMRI) can be used to identify targets, guide needles, and assess treatment outcomes. In this study, we evaluated the location of ablation zones relative to targeted lesions in 23 patients who underwent FLA therapy in a phase II trial. The ablation zone margins and unablated tumor volume were measured to determine whether complete coverage of each tumor was achieved, which would be considered a clinically successful ablation. METHODS Preoperative mpMRI was acquired for each patient 2-3 months preceding the procedure and the prostate and lesion(s) were manually contoured on 3 T T2-weighted axial images. The prostate and ablation zone(s) were also manually contoured on postablation 1.5 T T1-weighted contrast-enhanced axial images acquired immediately after the procedure intraoperatively. The lesion surface was nonrigidly registered to the postablation image using an initial affine registration followed by nonrigid thin-plate spline registration of the prostate surfaces. The margins between the registered lesion and ablation zone were calculated using a uniform spherical distribution of rays, and the volume of intersection was also calculated. Each prostate was contoured five times to determine the segmentation variability and its effect on intersection of the lesion and ablation zone. RESULTS Our study showed that the boundaries of the segmented tumor and ablation zone were close. Of the 23 lesions that were analyzed, 11 were completely covered by the ablation zone and 12 were partially covered. A shift of 1.0, 2.0, and 2.6 mm would result in 19, 21, and all tumors completely covered by the ablation zone, respectively. The median unablated tumor volume across all tumors was 0.1 mm 3 with an IQR of 3.7 mm 3 , which was 0.2% of the median tumor volume (46.5 mm 3 with an IQR of 46.3 mm 3 ). The median extension of the tumors beyond the ablation zone, in cases which were partially ablated, was 0.9 mm (IQR of 1.3 mm), with the furthest tumor extending 2.6 mm. CONCLUSION In all cases, the boundary of the tumor was close to the boundary of the ablation zone, and in some cases, the boundary of the ablation zone did not completely enclose the tumor. Our results suggest that some of the ablations were not clinically successful and that there is a need for more accurate needle tracking and guidance methods. Limitations of the study include errors in the registration and segmentation methods used as well as different voxel sizes and contrast between the registered T2 and T1 MRI sequences and asymmetric swelling of the prostate postprocedurally.
Collapse
Affiliation(s)
- Eric Knull
- Department of Biomedical Engineering, Western University, London, ON, N6A 3K7, Canada.,Robarts Research Institute, Western University, London, ON, N6A 5B7, Canada
| | - Aytekin Oto
- University of Chicago Medicine, Chicago, IL, 60637, USA
| | - Scott Eggener
- University of Chicago Medicine, Chicago, IL, 60637, USA
| | - David Tessier
- Robarts Research Institute, Western University, London, ON, N6A 5B7, Canada
| | - Serkan Guneyli
- Department of Radiology, University of Chicago, Chicago, IL, 60637, USA
| | | | - Aaron Fenster
- Robarts Research Institute, Western University, London, ON, N6A 5B7, Canada
| |
Collapse
|
5
|
Chen Y, Xu S, Squires A, Seifabadi R, Turkbey IB, Pinto PA, Choyke P, Wood B, Tse ZTH. MRI-Guided Robotically Assisted Focal Laser Ablation of the Prostate Using Canine Cadavers. IEEE Trans Biomed Eng 2017; 65:1434-1442. [PMID: 28961099 DOI: 10.1109/tbme.2017.2756907] [Citation(s) in RCA: 23] [Impact Index Per Article: 3.3] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/18/2022]
Abstract
OBJECTIVE a magnetic resonance imaging (MRI)-conditional needle guidance robot is developed to enhance MRI-guided focal laser ablation (FLA) therapy in patients with focal prostate cancer. METHODS inspired by the workflow of the manual FLA therapy, we developed an MRI-conditional robot with two degrees of freedom to provide the guidance for laser ablation catheter. This robot is powered by pneumatic turbine motors and encoded with the custom-designed optical encoder. The needle could be inserted manually through the designed robotic system, which keeps the patients inside MRI bore throughout the procedure. The robot hardware is integrated with the custom ablation planning and monitoring software (OncoNav) to provide an iterative treatment plan to cover the whole ablation zone. Virtual tumors were selected in three canine cadavers as targets to validate the performance of the proposed hardware and software system. RESULTS phantom studies show that the average targeting error is less than 2 mm and the workflow of the entire procedure lasts for 100 minutes. Canine cadaver experiment results show that all the targets were successfully ablated in no more than three administrations. SIGNIFICANCE MRI-guided prostate FLA is feasible using the proposed hardware and software system, indicating potential utility in future human trials.
Collapse
|
6
|
Su H, Shang W, Li G, Patel N, Fischer GS. An MRI-Guided Telesurgery System Using a Fabry-Perot Interferometry Force Sensor and a Pneumatic Haptic Device. Ann Biomed Eng 2017; 45:1917-1928. [PMID: 28447178 PMCID: PMC5529224 DOI: 10.1007/s10439-017-1839-z] [Citation(s) in RCA: 19] [Impact Index Per Article: 2.7] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/08/2016] [Accepted: 04/20/2017] [Indexed: 12/23/2022]
Abstract
This paper presents a surgical master-slave teleoperation system for percutaneous interventional procedures under continuous magnetic resonance imaging (MRI) guidance. The slave robot consists of a piezoelectrically actuated 6-degree-of-freedom (DOF) robot for needle placement with an integrated fiber optic force sensor (1-DOF axial force measurement) using the Fabry-Perot interferometry (FPI) sensing principle; it is configured to operate inside the bore of the MRI scanner during imaging. By leveraging the advantages of pneumatic and piezoelectric actuation in force and position control respectively, we have designed a pneumatically actuated master robot (haptic device) with strain gauge based force sensing that is configured to operate the slave from within the scanner room during imaging. The slave robot follows the insertion motion of the haptic device while the haptic device displays the needle insertion force as measured by the FPI sensor. Image interference evaluation demonstrates that the telesurgery system presents a signal to noise ratio reduction of less than 17% and less than 1% geometric distortion during simultaneous robot motion and imaging. Teleoperated needle insertion and rotation experiments were performed to reach 10 targets in a soft tissue-mimicking phantom with 0.70 ± 0.35 mm Cartesian space error.
Collapse
Affiliation(s)
- Hao Su
- Wyss Institute for Biologically Inspired Engineering and the John A. Paulson School of Engineering and Applied Sciences, Harvard University, Cambridge, MA, 02138, USA.
| | - Weijian Shang
- Automation and Interventional Medicine Robotics Laboratory, Department of Mechanical Engineering, Worcester Polytechnic Institute, 100 Institute Road, Worcester, MA, 01609, USA
| | - Gang Li
- Automation and Interventional Medicine Robotics Laboratory, Department of Mechanical Engineering, Worcester Polytechnic Institute, 100 Institute Road, Worcester, MA, 01609, USA
| | - Niravkumar Patel
- Automation and Interventional Medicine Robotics Laboratory, Department of Mechanical Engineering, Worcester Polytechnic Institute, 100 Institute Road, Worcester, MA, 01609, USA
| | - Gregory S Fischer
- Automation and Interventional Medicine Robotics Laboratory, Department of Mechanical Engineering, Worcester Polytechnic Institute, 100 Institute Road, Worcester, MA, 01609, USA
| |
Collapse
|
7
|
Jamaluddin MF, Ghosh S, Waine MP, Tavakoli M, Amanie J, Murtha AD, Yee D, Usmani N. Intraoperative factors associated with stranded source placement accuracy in low-dose-rate prostate brachytherapy. Brachytherapy 2017; 16:497-502. [PMID: 28190784 DOI: 10.1016/j.brachy.2017.01.007] [Citation(s) in RCA: 4] [Impact Index Per Article: 0.6] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/05/2016] [Revised: 01/12/2017] [Accepted: 01/13/2017] [Indexed: 12/01/2022]
Abstract
PURPOSE The quality of a low-dose rate prostate brachytherapy implant depends on the accurate placement of sources in their planned locations. This study investigates intraoperative factors that potentially contribute to stranded source placement inaccuracy in prostate brachytherapy. METHODS AND MATERIALS Intraoperative video images of the brachytherapist's hand motions and needle insertions during the implant procedure were acquired for analysis. Using video analysis software, maximum and average needle insertion velocities were determined. The number of needle insertion attempts and the use of the brachytherapist's other hand to manipulate the needle direction were also recorded. Sources misplacements were analyzed using an ultrasound-based method described elsewhere. RESULTS Fifteen patients agreed to undergo this study; 1619 125I seeds were inserted using 357 needles; 1197 seeds were confidently identified using ultrasound images and included in the analysis. The mean overall misplacement was 0.49 cm (0-2 cm, 95% CI = 0.47-0.51); 614 seeds were delivered with a single pass and 583 seeds with >1 passes (range 2-6). The mean maximum needle velocity was 12.34 cm s-1 (range 4-28 cm s-1) and mean average velocity was 4.76 cm s-1 (range 0.4-17.4 cm s-1); 747 seeds were delivered with manipulation of the needle. The generalized linear model test was used to analyze factors contributing to seed misplacement, and it was found that a maximum speed <12 cm s-1 was associated with a decrease in seed misplacement by 0.049 cm vs. a maximum speed >12 cm s-1, p = 0.0121). Other evaluated factors were found to have no statistically significant correlation with seed misplacement: average speed (p = 0.4947), manual manipulation of needle (p = 0.9264), and number of needle passes (p = 0.8907). CONCLUSIONS This study identified that needles inserted with lower maximum velocity were associated with less seed misplacement. Manual manipulation of the needle, number of passes, and average speed did not show statistically significant correlation with seed misplacement.
Collapse
Affiliation(s)
- M F Jamaluddin
- Department of Oncology, Faculty of Medicine and Dentistry, University of Alberta, Edmonton, AB, Canada
| | - S Ghosh
- Department of Oncology, Faculty of Medicine and Dentistry, University of Alberta, Edmonton, AB, Canada
| | - M P Waine
- Department of Electrical and Computer Engineering, Faculty of Engineering, University of Alberta, Edmonton, AB, Canada
| | - M Tavakoli
- Department of Electrical and Computer Engineering, Faculty of Engineering, University of Alberta, Edmonton, AB, Canada
| | - J Amanie
- Department of Oncology, Faculty of Medicine and Dentistry, University of Alberta, Edmonton, AB, Canada
| | - A D Murtha
- Department of Oncology, Faculty of Medicine and Dentistry, University of Alberta, Edmonton, AB, Canada
| | - D Yee
- Department of Oncology, Faculty of Medicine and Dentistry, University of Alberta, Edmonton, AB, Canada
| | - N Usmani
- Department of Oncology, Faculty of Medicine and Dentistry, University of Alberta, Edmonton, AB, Canada.
| |
Collapse
|
8
|
Chen Y, Squires A, Seifabadi R, Xu S, Agrawal H, Bernardo M, Pinto P, Choyke P, Wood B, Tse ZTH. Robotic System for MRI-guided Focal Laser Ablation in the Prostate. IEEE/ASME TRANSACTIONS ON MECHATRONICS : A JOINT PUBLICATION OF THE IEEE INDUSTRIAL ELECTRONICS SOCIETY AND THE ASME DYNAMIC SYSTEMS AND CONTROL DIVISION 2017; 22:107-114. [PMID: 31080341 PMCID: PMC6506217 DOI: 10.1109/tmech.2016.2611570] [Citation(s) in RCA: 16] [Impact Index Per Article: 2.3] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 05/14/2023]
Abstract
MRI-conditional robotic platforms have proved to be an effective approach for image guided interventions. In this study, a computer-assisted, pneumatically-actuated robot was designed, built, and tested for MRI-guided prostate cancer focal laser ablation (FLA). The robotic manipulator provides two active planar degrees of freedom (DoFs) by using a customized CoreXY frame, and one passive rotational DoF. A remote insertion mechanism improves the surgical workflow by keeping the patients inside the scanner during needle insertion. The robotic manipulator was tested in a 3T MR scanner to evaluate its MR compliance, and the results demonstrated that the signal-to-noise ratio (SNR) variation was less than 8%. The in-scanner template positioning accuracy test demonstrated that the manipulator achieves high targeting accuracy with a mean error of 0.46 mm and a standard deviation of 0.25mm. Phantom studies have shown that the needle insertion accuracy of the manipulator is within 2mm (Mean = 1.7mm, StD = 0.2mm).
Collapse
Affiliation(s)
- Yue Chen
- College of Engineering, The University of Georgia, Athens, GA, 30605, USA
| | - Alexander Squires
- College of Engineering, The University of Georgia, Athens, GA, 30605, USA
| | - Reza Seifabadi
- Center for Interventional Oncology, Department of Radiology and Imaging Sciences, National Institutes of Health, Bethesda, MD, 20892, USA
| | - Sheng Xu
- Center for Interventional Oncology, Department of Radiology and Imaging Sciences, National Institutes of Health, Bethesda, MD, 20892, USA
| | - Harsh Agrawal
- Philips Research North America, Briarcliff, NY, 10510, USA
| | - Marcelino Bernardo
- Center for Interventional Oncology, Department of Radiology and Imaging Sciences, National Institutes of Health, Bethesda, MD, 20892, USA
| | - Peter Pinto
- Center for Interventional Oncology, Department of Radiology and Imaging Sciences, National Institutes of Health, Bethesda, MD, 20892, USA
| | - Peter Choyke
- Center for Interventional Oncology, Department of Radiology and Imaging Sciences, National Institutes of Health, Bethesda, MD, 20892, USA
| | - Bradford Wood
- Center for Interventional Oncology, Department of Radiology and Imaging Sciences, National Institutes of Health, Bethesda, MD, 20892, USA
| | - Zion Tsz Ho Tse
- College of Engineering, The University of Georgia, Athens, GA, 30605, USA
| |
Collapse
|
9
|
Closed-Bore Interventional MRI: Percutaneous Biopsies and Ablations. AJR Am J Roentgenol 2015; 205:W400-10. [DOI: 10.2214/ajr.15.14732] [Citation(s) in RCA: 17] [Impact Index Per Article: 1.9] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/18/2022]
|
10
|
Abstract
Recent advances in multiparametric magnetic resonance imaging (mp-MRI) have led to a paradigm shift in the diagnosis and management of prostate cancer (PCa). Its sensitivity in detecting clinically significant cancer and the ability to localize the tumor within the prostate gland has opened up discussion on targeted diagnosis and therapy in PCa. Use of mp-MRI in conjunction with prostate-specific antigen followed by targeted biopsy allows for a better diagnostic pathway than transrectal ultrasound (TRUS) biopsy and improves the diagnosis of PCa. Improved detection of PCa by mp-MRI has also opened up opportunities for focal therapy within the organ while reducing the incidence of side-effects associated with the radical treatment methods for PCa. This review discusses the evidence and techniques for in-bore MRI-guided prostate biopsy and provides an update on the status of MRI-guided targeted focal therapy in PCa.
Collapse
Affiliation(s)
- Sangeet Ghai
- Joint Department of Medical Imaging, University Health Network, University of Toronto, Toronto, Canada
| | - John Trachtenberg
- Prostate Centre, Division of Urology, Department of Surgery, University Health Network, University of Toronto, Toronto, Canada
| |
Collapse
|