1
|
McTavish S, Van AT, Peeters JM, Weiss K, Harder FN, Makowski MR, Braren RF, Karampinos DC. Partial Fourier in the presence of respiratory motion in prostate diffusion-weighted echo planar imaging. MAGMA (NEW YORK, N.Y.) 2024:10.1007/s10334-024-01162-x. [PMID: 38743376 DOI: 10.1007/s10334-024-01162-x] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Subscribe] [Scholar Register] [Received: 11/06/2023] [Revised: 03/05/2024] [Accepted: 04/24/2024] [Indexed: 05/16/2024]
Abstract
PURPOSE To investigate the effect of respiratory motion in terms of signal loss in prostate diffusion-weighted imaging (DWI), and to evaluate the usage of partial Fourier in a free-breathing protocol in a clinically relevant b-value range using both single-shot and multi-shot acquisitions. METHODS A controlled breathing DWI acquisition was first employed at 3 T to measure signal loss from deep breathing patterns. Single-shot and multi-shot (2-shot) acquisitions without partial Fourier (no pF) and with partial Fourier (pF) factors of 0.75 and 0.65 were employed in a free-breathing protocol. The apparent SNR and ADC values were evaluated in 10 healthy subjects to measure if low pF factors caused low apparent SNR or overestimated ADC. RESULTS Controlled breathing experiments showed a difference in signal coefficient of variation between shallow and deep breathing. In free-breathing single-shot acquisitions, the pF 0.65 scan showed a significantly (p < 0.05) higher apparent SNR than pF 0.75 and no pF in the peripheral zone (PZ) of the prostate. In the multi-shot acquisitions in the PZ, pF 0.75 had a significantly higher apparent SNR than 0.65 pF and no pF. The single-shot pF 0.65 scan had a significantly lower ADC than single-shot no pF. CONCLUSION Deep breathing patterns can cause intravoxel dephasing in prostate DWI. For single-shot acquisitions at a b-value of 800 s/mm2, any potential risks of motion-related artefacts at low pF factors (pF 0.65) were outweighed by the increase in signal from a lower TE, as shown by the increase in apparent SNR. In multi-shot acquisitions however, the minimum pF factor should be larger, as shown by the lower apparent SNR at low pF factors.
Collapse
Affiliation(s)
- Sean McTavish
- Department of Diagnostic and Interventional Radiology, School of Medicine, Technical University of Munich, Ismaninger Str. 22, 81675, Munich, Germany.
| | - Anh T Van
- Department of Diagnostic and Interventional Radiology, School of Medicine, Technical University of Munich, Ismaninger Str. 22, 81675, Munich, Germany
| | | | | | - Felix N Harder
- Department of Diagnostic and Interventional Radiology, School of Medicine, Technical University of Munich, Ismaninger Str. 22, 81675, Munich, Germany
| | - Marcus R Makowski
- Department of Diagnostic and Interventional Radiology, School of Medicine, Technical University of Munich, Ismaninger Str. 22, 81675, Munich, Germany
| | - Rickmer F Braren
- Department of Diagnostic and Interventional Radiology, School of Medicine, Technical University of Munich, Ismaninger Str. 22, 81675, Munich, Germany
| | - Dimitrios C Karampinos
- Department of Diagnostic and Interventional Radiology, School of Medicine, Technical University of Munich, Ismaninger Str. 22, 81675, Munich, Germany
| |
Collapse
|
2
|
Zhang Z, Aygun E, Shih SF, Raman SS, Sung K, Wu HH. High-resolution prostate diffusion MRI using eddy current-nulled convex optimized diffusion encoding and random matrix theory-based denoising. MAGMA (NEW YORK, N.Y.) 2024:10.1007/s10334-024-01147-w. [PMID: 38349453 DOI: 10.1007/s10334-024-01147-w] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 05/01/2023] [Revised: 12/12/2023] [Accepted: 01/04/2024] [Indexed: 02/17/2024]
Abstract
OBJECTIVE To develop and evaluate a technique combining eddy current-nulled convex optimized diffusion encoding (ENCODE) with random matrix theory (RMT)-based denoising to accelerate and improve the apparent signal-to-noise ratio (aSNR) and apparent diffusion coefficient (ADC) mapping in high-resolution prostate diffusion-weighted MRI (DWI). MATERIALS AND METHODS: Eleven subjects with clinical suspicion of prostate cancer were scanned at 3T with high-resolution (HR) (in-plane: 1.0 × 1.0 mm2) ENCODE and standard-resolution (1.6 × 2.2 mm2) bipolar DWI sequences (both had 7 repetitions for averaging, acquisition time [TA] of 5 min 50 s). HR-ENCODE was retrospectively analyzed using three repetitions (accelerated effective TA of 2 min 30 s). The RMT-based denoising pipeline utilized complex DWI signals and Marchenko-Pastur distribution-based principal component analysis to remove additive Gaussian noise in images from multiple coils, b-values, diffusion encoding directions, and repetitions. HR-ENCODE with RMT-based denoising (HR-ENCODE-RMT) was compared with HR-ENCODE in terms of aSNR in prostate peripheral zone (PZ) and transition zone (TZ). Precision and accuracy of ADC were evaluated by the coefficient of variation (CoV) between repeated measurements and mean difference (MD) compared to the bipolar ADC reference, respectively. Differences were compared using two-sided Wilcoxon signed-rank tests (P < 0.05 considered significant). RESULTS HR-ENCODE-RMT yielded 62% and 56% higher median aSNR than HR-ENCODE (b = 800 s/mm2) in PZ and TZ, respectively (P < 0.001). HR-ENCODE-RMT achieved 63% and 70% lower ADC-CoV than HR-ENCODE in PZ and TZ, respectively (P < 0.001). HR-ENCODE-RMT ADC and bipolar ADC had low MD of 22.7 × 10-6 mm2/s in PZ and low MD of 90.5 × 10-6 mm2/s in TZ. CONCLUSIONS HR-ENCODE-RMT can shorten the acquisition time and improve the aSNR of high-resolution prostate DWI and achieve accurate and precise ADC measurements in the prostate.
Collapse
Affiliation(s)
- Zhaohuan Zhang
- Department of Radiological Sciences, University of California Los Angeles, 300 UCLA Medical Plaza, Suite B119, Los Angeles, CA, 90095, USA
- Department of Bioengineering, University of California Los Angeles, Los Angeles, CA, USA
| | - Elif Aygun
- Department of Radiological Sciences, University of California Los Angeles, 300 UCLA Medical Plaza, Suite B119, Los Angeles, CA, 90095, USA
- Department of Bioengineering, University of California Los Angeles, Los Angeles, CA, USA
| | - Shu-Fu Shih
- Department of Radiological Sciences, University of California Los Angeles, 300 UCLA Medical Plaza, Suite B119, Los Angeles, CA, 90095, USA
- Department of Bioengineering, University of California Los Angeles, Los Angeles, CA, USA
| | - Steven S Raman
- Department of Radiological Sciences, University of California Los Angeles, 300 UCLA Medical Plaza, Suite B119, Los Angeles, CA, 90095, USA
| | - Kyunghyun Sung
- Department of Radiological Sciences, University of California Los Angeles, 300 UCLA Medical Plaza, Suite B119, Los Angeles, CA, 90095, USA
- Department of Bioengineering, University of California Los Angeles, Los Angeles, CA, USA
| | - Holden H Wu
- Department of Radiological Sciences, University of California Los Angeles, 300 UCLA Medical Plaza, Suite B119, Los Angeles, CA, 90095, USA.
- Department of Bioengineering, University of California Los Angeles, Los Angeles, CA, USA.
| |
Collapse
|
3
|
Mir N, Fransen SJ, Wolterink JM, Fütterer JJ, Simonis FFJ. Recent Developments in Speeding up Prostate MRI. J Magn Reson Imaging 2023. [PMID: 37982353 DOI: 10.1002/jmri.29108] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/24/2023] [Revised: 10/13/2023] [Accepted: 10/17/2023] [Indexed: 11/21/2023] Open
Abstract
The increasing incidence of prostate cancer cases worldwide has led to a tremendous demand for multiparametric MRI (mpMRI). In order to relieve the pressure on healthcare, reducing mpMRI scan time is necessary. This review focuses on recent techniques proposed for faster mpMRI acquisition, specifically shortening T2W and DWI sequences while adhering to the PI-RADS (Prostate Imaging Reporting and Data System) guidelines. Speeding up techniques in the reviewed studies rely on more efficient sampling of data, ranging from the acquisition of fewer averages or b-values to adjustment of the pulse sequence. Novel acquisition methods based on undersampling techniques are often followed by suitable reconstruction methods typically incorporating synthetic priori information. These reconstruction methods often use artificial intelligence for various tasks such as denoising, artifact correction, improvement of image quality, and in the case of DWI, for the generation of synthetic high b-value images or apparent diffusion coefficient maps. Reduction of mpMRI scan time is possible, but it is crucial to maintain diagnostic quality, confirmed through radiological evaluation, to integrate the proposed methods into the standard mpMRI protocol. Additionally, before clinical integration, prospective studies are recommended to validate undersampling techniques to avoid potentially inaccurate results demonstrated by retrospective analysis. This review provides an overview of recently proposed techniques, discussing their implementation, advantages, disadvantages, and diagnostic performance according to PI-RADS guidelines compared to conventional methods. LEVEL OF EVIDENCE: 3 TECHNICAL EFFICACY: Stage 3.
Collapse
Affiliation(s)
- Nida Mir
- Magnetic Detection and Imaging, Technical Medical Centre, University of Twente, Enschede, Netherlands
| | - Stefan J Fransen
- Department of Radiology, University Medical Center Groningen, Groningen, Netherlands
| | - Jelmer M Wolterink
- Department of Applied Mathematics, Technical Medical Centre, University of Twente, Enschede, Netherlands
| | - Jurgen J Fütterer
- Robotics and Mechatronics, Technical Medical Centre, University of Twente, Enschede, Netherlands
- Minimally Invasive Image-Guided Interventions Center, Department of Medical Imaging, Radboud University Medical Center, Nijmegen, Netherlands
| | - Frank F J Simonis
- Magnetic Detection and Imaging, Technical Medical Centre, University of Twente, Enschede, Netherlands
| |
Collapse
|
4
|
Fennessy FM, Maier SE. Quantitative diffusion MRI in prostate cancer: Image quality, what we can measure and how it improves clinical assessment. Eur J Radiol 2023; 167:111066. [PMID: 37651828 PMCID: PMC10623580 DOI: 10.1016/j.ejrad.2023.111066] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/05/2023] [Revised: 08/19/2023] [Accepted: 08/24/2023] [Indexed: 09/02/2023]
Abstract
Diffusion-weighted imaging is a dependable method for detection of clinically significant prostate cancer. In prostate tissue, there are several compartments that can be distinguished from each other, based on different water diffusion decay signals observed. Alterations in cell architecture, such as a relative increase in tumor infiltration and decrease in stroma, will influence the observed diffusion signal in a voxel due to impeded random motion of water molecules. The amount of restricted diffusion can be assessed quantitatively by measuring the apparent diffusion coefficient (ADC) value. This is traditionally calculated using a monoexponential decay formula represented by the slope of a line produced between the logarithm of signal intensity decay plotted against selected b-values. However, the choice and number of b-values and their distribution, has a significant effect on the measured ADC values. There have been many models that attempt to use higher-order functions to better describe the observed diffusion signal decay, requiring an increased number and range of b-values. While ADC can probe heterogeneity on a macroscopic level, there is a need to optimize advanced diffusion techniques to better interrogate prostate tissue microstructure. This could be of benefit in clinical challenges such as identifying sparse tumors in normal prostate tissue or better defining tumor margins. This paper reviews the principles of diffusion MRI and novel higher order diffusion signal analysis techniques to improve the detection of prostate cancer.
Collapse
Affiliation(s)
- Fiona M Fennessy
- Department of Radiology, Brigham and Women's Hospital, Harvard Medical School, Boston, MA, United States.
| | - Stephan E Maier
- Department of Radiology, Brigham and Women's Hospital, Harvard Medical School, Boston, MA, United States; Department of Radiology, Institute of Clinical Sciences, Sahlgrenska Academy, University of Gothenburg, Gothenburg, Sweden
| |
Collapse
|
5
|
Hernando D, Zhang Y, Pirasteh A. Quantitative diffusion MRI of the abdomen and pelvis. Med Phys 2021; 49:2774-2793. [PMID: 34554579 DOI: 10.1002/mp.15246] [Citation(s) in RCA: 3] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/06/2021] [Revised: 08/05/2021] [Accepted: 09/15/2021] [Indexed: 12/14/2022] Open
Abstract
Diffusion MRI has enormous potential and utility in the evaluation of various abdominal and pelvic disease processes including cancer and noncancer imaging of the liver, prostate, and other organs. Quantitative diffusion MRI is based on acquisitions with multiple diffusion encodings followed by quantitative mapping of diffusion parameters that are sensitive to tissue microstructure. Compared to qualitative diffusion-weighted MRI, quantitative diffusion MRI can improve standardization of tissue characterization as needed for disease detection, staging, and treatment monitoring. However, similar to many other quantitative MRI methods, diffusion MRI faces multiple challenges including acquisition artifacts, signal modeling limitations, and biological variability. In abdominal and pelvic diffusion MRI, technical acquisition challenges include physiologic motion (respiratory, peristaltic, and pulsatile), image distortions, and low signal-to-noise ratio. If unaddressed, these challenges lead to poor technical performance (bias and precision) and clinical outcomes of quantitative diffusion MRI. Emerging and novel technical developments seek to address these challenges and may enable reliable quantitative diffusion MRI of the abdomen and pelvis. Through systematic validation in phantoms, volunteers, and patients, including multicenter studies to assess reproducibility, these emerging techniques may finally demonstrate the potential of quantitative diffusion MRI for abdominal and pelvic imaging applications.
Collapse
Affiliation(s)
- Diego Hernando
- Departments of Radiology and Medical Physics, University of Wisconsin-Madison, Madison, Wisconsin, USA
| | - Yuxin Zhang
- Departments of Radiology and Medical Physics, University of Wisconsin-Madison, Madison, Wisconsin, USA
| | - Ali Pirasteh
- Departments of Radiology and Medical Physics, University of Wisconsin-Madison, Madison, Wisconsin, USA
| |
Collapse
|