1
|
Son A, Kim W, Park J, Park Y, Lee W, Lee S, Kim H. Mass Spectrometry Advancements and Applications for Biomarker Discovery, Diagnostic Innovations, and Personalized Medicine. Int J Mol Sci 2024; 25:9880. [PMID: 39337367 PMCID: PMC11432749 DOI: 10.3390/ijms25189880] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/08/2024] [Revised: 09/04/2024] [Accepted: 09/10/2024] [Indexed: 09/30/2024] Open
Abstract
Mass spectrometry (MS) has revolutionized clinical chemistry, offering unparalleled capabilities for biomolecule analysis. This review explores the growing significance of mass spectrometry (MS), particularly when coupled with liquid chromatography (LC), in identifying disease biomarkers and quantifying biomolecules for diagnostic and prognostic purposes. The unique advantages of MS in accurately identifying and quantifying diverse molecules have positioned it as a cornerstone in personalized-medicine advancement. MS-based technologies have transformed precision medicine, enabling a comprehensive understanding of disease mechanisms and patient-specific treatment responses. LC-MS has shown exceptional utility in analyzing complex biological matrices, while high-resolution MS has expanded analytical capabilities, allowing the detection of low-abundance molecules and the elucidation of complex biological pathways. The integration of MS with other techniques, such as ion mobility spectrometry, has opened new avenues for biomarker discovery and validation. As we progress toward precision medicine, MS-based technologies will be crucial in addressing the challenges of individualized patient care, driving innovations in disease diagnosis, prognosis, and treatment strategies.
Collapse
Affiliation(s)
- Ahrum Son
- Department of Molecular Medicine, Scripps Research, San Diego, CA 92037, USA
| | - Woojin Kim
- Department of Bio-AI Convergence, Chungnam National University, Daejeon 34134, Republic of Korea
| | - Jongham Park
- Department of Bio-AI Convergence, Chungnam National University, Daejeon 34134, Republic of Korea
| | - Yongho Park
- Department of Bio-AI Convergence, Chungnam National University, Daejeon 34134, Republic of Korea
| | - Wonseok Lee
- Department of Bio-AI Convergence, Chungnam National University, Daejeon 34134, Republic of Korea
| | - Sangwoon Lee
- Department of Bio-AI Convergence, Chungnam National University, Daejeon 34134, Republic of Korea
| | - Hyunsoo Kim
- Department of Bio-AI Convergence, Chungnam National University, Daejeon 34134, Republic of Korea
- Department of Convergent Bioscience and Informatics, Chungnam National University, 99 Daehak-ro, Yuseong-gu, Daejeon 34134, Republic of Korea
- Protein AI Design Institute, Chungnam National University, 99 Daehak-ro, Yuseong-gu, Daejeon 34134, Republic of Korea
- SCICS, 99 Daehak-ro, Yuseong-gu, Daejeon 34134, Republic of Korea
| |
Collapse
|
2
|
Wenk D, Zuo C, Kislinger T, Sepiashvili L. Recent developments in mass-spectrometry-based targeted proteomics of clinical cancer biomarkers. Clin Proteomics 2024; 21:6. [PMID: 38287260 PMCID: PMC10826105 DOI: 10.1186/s12014-024-09452-1] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/10/2023] [Accepted: 01/14/2024] [Indexed: 01/31/2024] Open
Abstract
Routine measurement of cancer biomarkers is performed for early detection, risk classification, and treatment monitoring, among other applications, and has substantially contributed to better clinical outcomes for patients. However, there remains an unmet need for clinically validated assays of cancer protein biomarkers. Protein tumor markers are of particular interest since proteins carry out the majority of biological processes and thus dynamically reflect changes in cancer pathophysiology. Mass spectrometry-based targeted proteomics is a powerful tool for absolute peptide and protein quantification in biological matrices with numerous advantages that make it attractive for clinical applications in oncology. The use of liquid chromatography-tandem mass spectrometry (LC-MS/MS) based methodologies has allowed laboratories to overcome challenges associated with immunoassays that are more widely used for tumor marker measurements. Yet, clinical implementation of targeted proteomics methodologies has so far been limited to a few cancer markers. This is due to numerous challenges associated with paucity of robust validation studies of new biomarkers and the labor-intensive and operationally complex nature of LC-MS/MS workflows. The purpose of this review is to provide an overview of targeted proteomics applications in cancer, workflows used in targeted proteomics, and requirements for clinical validation and implementation of targeted proteomics assays. We will also discuss advantages and challenges of targeted MS-based proteomics assays for clinical cancer biomarker analysis and highlight some recent developments that will positively contribute to the implementation of this technique into clinical laboratories.
Collapse
Affiliation(s)
- Deborah Wenk
- Princess Margaret Cancer Centre, University Health Network, Toronto, ON, Canada
| | - Charlotte Zuo
- Princess Margaret Cancer Centre, University Health Network, Toronto, ON, Canada
| | - Thomas Kislinger
- Princess Margaret Cancer Centre, University Health Network, Toronto, ON, Canada.
- Department of Medical Biophysics, University of Toronto, Toronto, ON, Canada.
- Princess Margaret Cancer Research Tower, Room 9-807, 101 College Street, Toronto, ON, M5G 1L7, Canada.
| | - Lusia Sepiashvili
- Department of Paediatric Laboratory Medicine, The Hospital for Sick Children, 555 University Ave, Rm 3606, Toronto, ON, M5G 1X8, Canada.
- Department of Laboratory Medicine & Pathobiology, University of Toronto, Toronto, ON, Canada.
- Sickkids Research Institute, Toronto, ON, Canada.
| |
Collapse
|
3
|
Lee TJ, Goyal A, Jones G, Glass J, Doshi V, Bollinger K, Ulrich L, Ahmed S, Kodeboyina SK, Estes A, Töteberg-Harms M, Zhi W, Sharma S, Sharma A. AHP DB: a reference database of proteins in the human aqueous humor. Database (Oxford) 2024; 2024:baae001. [PMID: 38284936 PMCID: PMC10878049 DOI: 10.1093/database/baae001] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/25/2023] [Revised: 12/20/2023] [Accepted: 01/05/2024] [Indexed: 01/30/2024]
Abstract
The aqueous humor (AH) is a low-viscosity biofluid that continuously circulates from the posterior chamber to the anterior chamber of the eye. Recent advances in high-resolution mass-spectrometry workflows have facilitated the study of proteomic content in small-volume biofluids like AH, highlighting the potential clinical implications of the AH proteome. Nevertheless, in-depth investigations into the role of AH proteins in ocular diseases have encountered challenges due to limited accessibility to these workflows, difficulties in large-scale AH sample collection and the absence of a reference AH proteomic database. In response to these obstacles, and to promote further research on the involvement of AH proteins in ocular physiology and pathology, we have developed the web-based Aqueous Humor Proteomics Database (AHP DB). The current version of AHP DB contains proteomic data from 307 human AH samples, which were analyzed using liquid chromatography-tandem mass spectrometry (LC-MS/MS). The database offers comprehensive information on 1683 proteins identified in the AH samples. Furthermore, relevant clinical data are provided for each analyzed sample. Researchers also have the option to download these datasets individually for offline use, rendering it a valuable resource for the scientific community. Database URL: https://ahp.augusta.edu/.
Collapse
Affiliation(s)
- Tae Jin Lee
- Center for Biotechnology and Genomic Medicine, Medical College of Georgia, Augusta University, 1120 15th Street, Augusta, GA 30912, USA
| | - Arnav Goyal
- Center for Biotechnology and Genomic Medicine, Medical College of Georgia, Augusta University, 1120 15th Street, Augusta, GA 30912, USA
| | - Garrett Jones
- Center for Biotechnology and Genomic Medicine, Medical College of Georgia, Augusta University, 1120 15th Street, Augusta, GA 30912, USA
| | - Joshua Glass
- Center for Biotechnology and Genomic Medicine, Medical College of Georgia, Augusta University, 1120 15th Street, Augusta, GA 30912, USA
| | - Vishal Doshi
- Center for Biotechnology and Genomic Medicine, Medical College of Georgia, Augusta University, 1120 15th Street, Augusta, GA 30912, USA
| | - Kathryn Bollinger
- Department of Ophthalmology, Medical College of Georgia, Augusta University, 1120 15th Street, Augusta, GA 30912, USA
| | - Lane Ulrich
- Department of Ophthalmology, Medical College of Georgia, Augusta University, 1120 15th Street, Augusta, GA 30912, USA
| | - Saleh Ahmed
- Center for Biotechnology and Genomic Medicine, Medical College of Georgia, Augusta University, 1120 15th Street, Augusta, GA 30912, USA
| | - Sai Karthik Kodeboyina
- Center for Biotechnology and Genomic Medicine, Medical College of Georgia, Augusta University, 1120 15th Street, Augusta, GA 30912, USA
- Mass General Brigham, 399 Revolution Drive, Somerville, MA 02145, USA
| | - Amy Estes
- Department of Ophthalmology, Medical College of Georgia, Augusta University, 1120 15th Street, Augusta, GA 30912, USA
| | - Marc Töteberg-Harms
- Department of Ophthalmology, Medical College of Georgia, Augusta University, 1120 15th Street, Augusta, GA 30912, USA
| | - Wenbo Zhi
- Center for Biotechnology and Genomic Medicine, Medical College of Georgia, Augusta University, 1120 15th Street, Augusta, GA 30912, USA
| | - Shruti Sharma
- Center for Biotechnology and Genomic Medicine, Medical College of Georgia, Augusta University, 1120 15th Street, Augusta, GA 30912, USA
- Department of Ophthalmology, Medical College of Georgia, Augusta University, 1120 15th Street, Augusta, GA 30912, USA
| | - Ashok Sharma
- Center for Biotechnology and Genomic Medicine, Medical College of Georgia, Augusta University, 1120 15th Street, Augusta, GA 30912, USA
- Department of Ophthalmology, Medical College of Georgia, Augusta University, 1120 15th Street, Augusta, GA 30912, USA
- Department of Population Health Sciences, Medical College of Georgia, Augusta University, 1120 15th Street, Augusta, GA 30912, USA
| |
Collapse
|
4
|
Victoria Zhang Y, Garg U. Mass Spectrometry in Clinical Laboratory: Applications in Therapeutic Drug Monitoring and Toxicology. Methods Mol Biol 2024; 2737:1-13. [PMID: 38036805 DOI: 10.1007/978-1-0716-3541-4_1] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/02/2023]
Abstract
Mass spectrometry (MS) coupled with liquid chromatography (LC) or gas chromatography (GC) has been proven to be a powerful platform in research and specialized clinical laboratories for decades. In clinical laboratories, it is used for compound identification and quantification. Due to the ability to provide specific identification, high sensitivity, and simultaneous analysis of multiple analytes (>100) in recent years, application of MS in routine clinical laboratories has increased significantly. Although MS is used in many laboratory areas, therapeutic drug monitoring, drugs of abuse, and clinical toxicology remain the primary focuses of the field. Due to rapid increase in the number of prescription drugs and drugs of abuse (e.g., novel psychoactive substances), clinical laboratories are challenged with developing new MS assays to meet the clinical needs of the patients. We are here to present "off-the-shelf" and "ready-to-use" protocols of recent developments in new assays to help the clinical laboratory community adopt the technology and analysis for the betterment of patient care.
Collapse
Affiliation(s)
- Y Victoria Zhang
- Department of Pathology and Laboratory Medicine, University of Rochester, Rochester, NY, USA
| | - Uttam Garg
- Department of Pathology and Laboratory Medicine, Children's Mercy Hospital, Kansas City, MO, USA.
- University of Missouri School of Medicine, Kansas City, MO, USA.
| |
Collapse
|
5
|
Gqamana PP, Militello L, McMaster JM, Daley SJ, Zhang YV. Analytical Concordance of Total Vitamin D on a Fully Automated Random-Access LC-MS/MS Platform. J Appl Lab Med 2023; 8:940-951. [PMID: 37473445 DOI: 10.1093/jalm/jfad036] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/11/2023] [Accepted: 04/05/2023] [Indexed: 07/22/2023]
Abstract
BACKGROUND The adoption of LC-MS/MS laboratory developed tests in the clinical laboratory is limited by many factors including the lack of automation. Recently, the Cascadion™ clinical analyzer was introduced as a fully automated random-access LC-MS/MS platform. Here, the analytical concordance between the platform and a Roche immunoassay analyzer was investigated for vitamin D analysis in human serum, including samples selected for high triglyceride levels. METHODS Analytical precision was evaluated on 3 levels of QC samples (10, 30, and 90 ng/mL) within days (n = 4, 5 days) and between days (20 days). Assay comparison to the Roche was performed using reference samples from the CDC and CAP programs for accuracy. Concordance was also monitored using routine patient samples, as well as samples selected for elevated triglyceride levels (>250 mg/dL). RESULTS Precision met manufacturer specifications (<10% CV and <15% bias), whereas the accuracy evaluations showed a linear fit (y = 0.97x - 1.1, r = 0.995) with 1:1 correlation to reference samples, independent of C-3-epi-vitamin D levels. A mean positive bias (11%) was observed for the Roche measurements in normal patient samples, whereas a mean negative bias (-8%) was observed in samples selected for elevated triglyceride levels. CONCLUSIONS Cascadion measurements of total vitamin D compared favorably with Roche results in our laboratory, although discordance was observed in the analysis of patient serum, which could be explained in terms of known differences between the 2 assays. However, operational issues need to be addressed to effect clinical adoption.
Collapse
Affiliation(s)
- Putuma P Gqamana
- Department of Pathology and Laboratory Medicine, University of Rochester Medical Center, Rochester, NY, United States
| | - Leah Militello
- Department of Pathology and Laboratory Medicine, University of Rochester Medical Center, Rochester, NY, United States
| | - Jeffrey M McMaster
- Department of Pathology and Laboratory Medicine, University of Rochester Medical Center, Rochester, NY, United States
| | - Stacy J Daley
- Department of Pathology and Laboratory Medicine, University of Rochester Medical Center, Rochester, NY, United States
| | - Y Victoria Zhang
- Department of Pathology and Laboratory Medicine, University of Rochester Medical Center, Rochester, NY, United States
| |
Collapse
|
6
|
Birhanu AG. Mass spectrometry-based proteomics as an emerging tool in clinical laboratories. Clin Proteomics 2023; 20:32. [PMID: 37633929 PMCID: PMC10464495 DOI: 10.1186/s12014-023-09424-x] [Citation(s) in RCA: 36] [Impact Index Per Article: 18.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/08/2023] [Accepted: 08/03/2023] [Indexed: 08/28/2023] Open
Abstract
Mass spectrometry (MS)-based proteomics have been increasingly implemented in various disciplines of laboratory medicine to identify and quantify biomolecules in a variety of biological specimens. MS-based proteomics is continuously expanding and widely applied in biomarker discovery for early detection, prognosis and markers for treatment response prediction and monitoring. Furthermore, making these advanced tests more accessible and affordable will have the greatest healthcare benefit.This review article highlights the new paradigms MS-based clinical proteomics has created in microbiology laboratories, cancer research and diagnosis of metabolic disorders. The technique is preferred over conventional methods in disease detection and therapy monitoring for its combined advantages in multiplexing capacity, remarkable analytical specificity and sensitivity and low turnaround time.Despite the achievements in the development and adoption of a number of MS-based clinical proteomics practices, more are expected to undergo transition from bench to bedside in the near future. The review provides insights from early trials and recent progresses (mainly covering literature from the NCBI database) in the application of proteomics in clinical laboratories.
Collapse
|
7
|
Direct oral anticoagulants (DOACs): From the laboratory point of view. ACTA PHARMACEUTICA (ZAGREB, CROATIA) 2022; 72:459-482. [PMID: 36651369 DOI: 10.2478/acph-2022-0034] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Subscribe] [Scholar Register] [Accepted: 08/09/2022] [Indexed: 01/20/2023]
Abstract
Direct oral anticoagulants (DOACs) represent a new generation of drugs that have been increasingly used in the prevention and treatment of thromboembolic states. According to the mechanism of anticoagulant action, DOACs are divided into two groups: direct inhibitors of thrombin (dabigatran) and direct inhibitors of activated factor X (FXa) (rivaroxaban, apixaban, edoxaban, betrixaban). Compared to the vitamin K antagonists, DOACs are superior in terms of onset of action, pharmacokinetic and pharmacodynamics properties and fixed daily dose without the need for routine coagulation monitoring. Despite these advantages, there are clinical conditions in which laboratory measurement of DOACs should be performed. Although DOACs have an impact on screening haemostasis assays (prothrombin time, PT; activated partial thromboplastin time, aPTT; and thrombin time, TT), these tests are not appropriate for quantifying drug levels. Therefore, specific quantitative methods (LC-MS/MS as a gold standard method for all DOACs, coagulometric and chromogenic assays for dabigatran, and chromogenic anti-Xa assays with drug-specific calibrators for inhibitors of FXa) should only be used for determination of DOACs concentration. The aim of this review is to present all aspects of laboratory assessment of DOACs, including pre-analytical, analytical and post-analytical factors in the overall testing process with a special accent on the available specific quantitative methods for measurement of DOACs in circulation.
Collapse
|
8
|
Introduction to Mass Spectrometry for Bimolecular Analysis in a Clinical Laboratory. Methods Mol Biol 2022; 2546:1-12. [PMID: 36127573 DOI: 10.1007/978-1-0716-2565-1_1] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/14/2022]
Abstract
Mass spectrometry is a technique that identifies analytes based on mass-to-charge (m/z) ratio and structural fragments. Although this technique has been used in research and specialized clinical laboratories for decades, only in recent years has mass spectrometry become popular in routine clinical laboratories. Mass spectrometry, especially when coupled with gas chromatography or liquid chromatography, provides very specific and often sensitive analysis of many analytes. Other advantages of mass spectrometry include simultaneous analysis of multiple analytes (>100) and generally limited requirement for specialized reagents. Commonly measured analytes by mass spectrometry include metabolites, drugs, hormones, and proteins.
Collapse
|
9
|
Skaggs C, Zimmerman H, Manicke N, Kirkpatrick L. Development and validation of a paper spray mass spectrometry method for the rapid quantitation of remdesivir and its active metabolite, GS-441524, in human plasma. J Mass Spectrom Adv Clin Lab 2022; 25:27-35. [PMID: 35721272 PMCID: PMC9188284 DOI: 10.1016/j.jmsacl.2022.06.001] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/02/2021] [Revised: 05/21/2022] [Accepted: 06/01/2022] [Indexed: 11/17/2022] Open
Abstract
Rapid PS-MS/MS quantification of remdesivir and its active metabolite, GS-441524, directly from plasma. No sample preparation, short turn-around time, use of stable isotope-labeled internal standards. Robust stability data are presented. Suitable for adjusting remdesivir dosage for optimal efficacy and minimal toxicity.
Introduction Remdesivir (GS-5734) is a nucleoside analog prodrug with antiviral activity against several single-stranded RNA viruses, including the novel severe respiratory distress syndrome virus 2 (SARS-CoV-2). It is currently the only FDA-approved antiviral agent for the treatment of individuals with COVID-19 caused by SARS-CoV-2. However, remdesivir pharmacokinetics/pharmacodynamics (PK/PD) and toxicity data in humans are extremely limited. It is imperative that precise analytical methods for the quantification of remdesivir and its active metabolite, GS-441524, are developed for use in further studies. We report, herein, the first validated anti-viral paper spray-mass spectrometry (PS-MS/MS) assay for the quantification of remdesivir and GS-441524 in human plasma. We seek to highlight the utility of PS-MS/MS technology and automation advancements for its potential future use in clinical research and the clinical laboratory setting. Methods Calibration curves for remdesivir and GS-441524 were created utilizing seven plasma-based calibrants of varying concentrations and two isotopic internal standards of set concentrations. Four plasma-based quality controls were prepared in a similar fashion to the calibrants and utilized for validation. No sample preparation was needed. Briefly, plasma samples were spotted on a paper substrate contained within pre-manufactured plastic cassette plates, and the spots were dried for 1 h. The samples were then analyzed directly for 1.2 min utilizing PS-MS/MS. All experiments were performed on a Thermo Scientific Altis triple quadrupole mass spectrometer utilizing automated technology. Results The calibration ranges were 20 – 5000 and 100 – 25000 ng/mL for remdesivir and GS-441524, respectively. The calibration curves for the two antiviral agents showed excellent linearity (average R2 = 0.99–1.00). The inter- and intra-day precision (%CV) across validation runs at four QC levels for both analytes was less than 11.2% and accuracy (%bias) was within ± 15%. Plasma calibrant stability was assessed and degradation for the 4 °C and room temperature samples were seen beginning at Day 7. The plasma calibrants were stable at −20 °C. No interference, matrix effects, or carryover was discovered during the validation process. Conclusions PS-MS/MS represents a useful methodology for rapidly quantifying remdesivir and GS-441524, which may be useful for clinical PK/PD, therapeutic drug monitoring (TDM), and toxicity assessment, particularly during the current COVID-19 pandemic and future viral outbreaks.
Collapse
|
10
|
Thomas SN, French D, Jannetto PJ, Rappold BA, Clarke WA. Liquid chromatography–tandem mass spectrometry for clinical diagnostics. NATURE REVIEWS. METHODS PRIMERS 2022; 2:96. [PMCID: PMC9735147 DOI: 10.1038/s43586-022-00175-x] [Citation(s) in RCA: 78] [Impact Index Per Article: 26.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Figures] [Subscribe] [Scholar Register] [Accepted: 10/07/2022] [Indexed: 12/13/2022]
Abstract
Mass spectrometry is a powerful analytical tool used for the analysis of a wide range of substances and matrices; it is increasingly utilized for clinical applications in laboratory medicine. This Primer includes an overview of basic mass spectrometry concepts, focusing primarily on tandem mass spectrometry. We discuss experimental considerations and quality management, and provide an overview of some key applications in the clinic. Lastly, the Primer discusses significant challenges for implementation of mass spectrometry in clinical laboratories and provides an outlook of where there are emerging clinical applications for this technology. Tandem mass spectrometry is increasingly utilized for clinical applications in laboratory medicine. In this Primer, Thomas et al. discuss experimental considerations and quality management for implementing clinical tandem mass spectrometry in the clinic with an overview of some key applications.
Collapse
Affiliation(s)
- Stefani N. Thomas
- grid.17635.360000000419368657Laboratory Medicine and Pathology, University of Minnesota, Minneapolis, MN USA
| | - Deborah French
- grid.266102.10000 0001 2297 6811Laboratory Medicine, University of California San Francisco, San Francisco, CA USA
| | - Paul J. Jannetto
- grid.66875.3a0000 0004 0459 167XDepartment of Pathology & Laboratory Medicine, Mayo Clinic, Rochester, MN USA
| | - Brian A. Rappold
- grid.419316.80000 0004 0550 1859Research and Development, Labcorp, Burlington, NC USA
| | - William A. Clarke
- grid.21107.350000 0001 2171 9311Department of Pathology, Johns Hopkins University School of Medicine, Baltimore, MD USA
| |
Collapse
|
11
|
Skaggs CL, Ren GJ, Elgierari ETM, Sturmer LR, Shi RZ, Manicke NE, Kirkpatrick LM. Simultaneous quantitation of five triazole anti-fungal agents by paper spray-mass spectrometry. Clin Chem Lab Med 2021; 58:836-846. [PMID: 31926066 DOI: 10.1515/cclm-2019-0895] [Citation(s) in RCA: 12] [Impact Index Per Article: 3.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/22/2019] [Accepted: 11/04/2019] [Indexed: 12/25/2022]
Abstract
Background Invasive fungal disease is a life-threatening condition that can be challenging to treat due to pathogen resistance, drug toxicity, and therapeutic failure secondary to suboptimal drug concentrations. Frequent therapeutic drug monitoring (TDM) is required for some anti-fungal agents to overcome these issues. Unfortunately, TDM at the institutional level is difficult, and samples are often sent to a commercial reference laboratory for analysis. To address this gap, the first paper spray-mass spectrometry assay for the simultaneous quantitation of five triazoles was developed. Methods Calibration curves for fluconazole, posaconazole, itraconazole, hydroxyitraconazole, and voriconazole were created utilizing plasma-based calibrants and four stable isotopic internal standards. No sample preparation was needed. Plasma samples were spotted on a paper substrate in pre-manufactured plastic cartridges, and the dried plasma spots were analyzed directly utilizing paper spray-mass spectrometry (paper spray MS/MS). All experiments were performed on a Thermo Scientific TSQ Vantage triple quadrupole mass spectrometer. Results The calibration curves for the five anti-fungal agents showed good linearity (R2 = 0.98-1.00). The measured assay ranges (lower limit of quantification [LLOQ]-upper limit of quantitation [ULOQ]) for fluconazole, posaconazole, itraconazole, hydroxyitraconazole, and voriconazole were 0.5-50 μg/mL, 0.1-10 μg/mL, 0.1-10 μg/mL, 0.1-10 μg/mL, and 0.1-10 μg/mL, respectively. The inter- and intra-day accuracy and precision were less than 25% over the respective ranges. Conclusions We developed the first rapid paper spray-MS/MS assay for simultaneous quantitation of five triazole anti-fungal agents in plasma. The method may be a powerful tool for near-point-of-care TDM aimed at improving patient care by reducing the turnaround time and for use in clinical research.
Collapse
Affiliation(s)
- Christine L Skaggs
- Department of Chemistry and Chemical Biology, Indiana University-Purdue University Indianapolis, Indianapolis, IN, USA
| | - Greta J Ren
- Department of Chemistry and Chemical Biology, Indiana University-Purdue University Indianapolis, Indianapolis, IN, USA
| | | | - Lillian R Sturmer
- Department of Pathology, Stanford University School of Medicine, Stanford, CA, USA
| | - Run Z Shi
- Department of Pathology, Stanford University School of Medicine, Stanford, CA, USA
| | - Nicholas E Manicke
- Department of Chemistry and Chemical Biology, Indiana University-Purdue University Indianapolis, Indianapolis, IN, USA.,Forensic and Investigative Sciences, Indiana University-Purdue University Indianapolis, Indianapolis, IN, USA
| | - Lindsey M Kirkpatrick
- Department of Pediatrics, Division of Pediatric Infectious Diseases, J.W. Riley Hospital for Children, Indiana University School of Medicine, 705 Riley Hospital Drive, Indianapolis, IN, 46202, USA
| |
Collapse
|
12
|
Tandem mass spectrometry in the clinical laboratory: A tutorial overview. CLINICAL MASS SPECTROMETRY 2020. [DOI: 10.1016/j.clinms.2019.09.002] [Citation(s) in RCA: 8] [Impact Index Per Article: 1.6] [Reference Citation Analysis] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 12/27/2022]
|
13
|
Rankin NJ, Burgess K, Weidt S, Wannamethee G, Sattar N, Welsh P. High-throughput quantification of carboxymethyl lysine in serum and plasma using high-resolution accurate mass Orbitrap mass spectrometry. Ann Clin Biochem 2019; 56:397-407. [PMID: 30832481 PMCID: PMC6498755 DOI: 10.1177/0004563219830432] [Citation(s) in RCA: 4] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Accepted: 12/27/2018] [Indexed: 12/28/2022]
Abstract
BACKGROUND Carboxymethyl lysine is an advanced glycation end product of interest as a potential biomarker of cardiovascular and other diseases. Available methods involve ELISA, with potential interference, or isotope dilution mass spectrometry (IDMS), with low-throughput sample preparation. METHODS A high-throughput sample preparation method based on 96-well plates was developed. Protein-bound carboxymethyl lysine and lysine were quantified by IDMS using reversed phase chromatography coupled to a high-resolution accurate mass Orbitrap Exactive mass spectrometer. The carboxymethyl lysine concentration (normalized to lysine concentration) was measured in 1714 plasma samples from the British Regional Heart Study (BRHS). RESULTS For carboxymethyl lysine, the lower limit of quantification (LLOQ) was estimated at 0.16 μM and the assay was linear between 0.25 and 10 μM. For lysine, the LLOQ was estimated at 3.79 mM, and the assay was linear between 2.5 and 100 mM. The intra-assay coefficient of variation was 17.2% for carboxymethyl lysine, 9.3% for lysine and 10.5% for normalized carboxymethyl lysine. The inter-assay coefficient of variation was 18.1% for carboxymethyl lysine, 14.8 for lysine and 16.2% for normalized carboxymethyl lysine. The median and inter-quartile range of all study samples in each batch were monitored. A mean carboxymethyl lysine concentration of 2.7 μM (IQR 2.0-3.2 μM, range 0.2-17.4 μM) and a mean normalized carboxymethyl lysine concentration of 69 μM/M lysine (IQR 54-76 μM/M, range 19-453 μM/M) were measured in the BRHS. CONCLUSION This high-throughput sample preparation method makes it possible to analyse large cohorts required to determine the potential of carboxymethyl lysine as a biomarker.
Collapse
Affiliation(s)
- Naomi J Rankin
- Institute of Cardiovascular and Medical Sciences (ICAMS), BHF Glasgow Cardiovascular Research Centre, University of Glasgow, Glasgow, UK
- Glasgow Polyomics, University of Glasgow, Glasgow, UK
| | - Karl Burgess
- Institute of Quantitive Biology, Biochemistry and Biotechnology, University of Edinburgh, Edinburgh, UK
| | - Stefan Weidt
- Glasgow Polyomics, University of Glasgow, Glasgow, UK
| | - Goya Wannamethee
- Primary Care and Population Health, Royal Free Campus, University College London Medical School, London, UK
| | - Naveed Sattar
- Institute of Cardiovascular and Medical Sciences (ICAMS), BHF Glasgow Cardiovascular Research Centre, University of Glasgow, Glasgow, UK
| | - Paul Welsh
- Institute of Cardiovascular and Medical Sciences (ICAMS), BHF Glasgow Cardiovascular Research Centre, University of Glasgow, Glasgow, UK
| |
Collapse
|
14
|
Chatziathanasiadou MV, Stylos EK, Giannopoulou E, Spyridaki MH, Briasoulis E, Kalofonos HP, Crook T, Syed N, Sivolapenko GB, Tzakos AG. Development of a validated LC-MS/MS method for the in vitro and in vivo quantitation of sunitinib in glioblastoma cells and cancer patients. J Pharm Biomed Anal 2019; 164:690-697. [DOI: 10.1016/j.jpba.2018.11.030] [Citation(s) in RCA: 5] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/08/2018] [Revised: 11/05/2018] [Accepted: 11/12/2018] [Indexed: 12/28/2022]
|
15
|
Douxfils J, Pochet L, Lessire S, Vancraeynest C, Dogné JM, Mullier F. Mass spectrometry in the therapeutic drug monitoring of direct oral anticoagulants. Useful or useless? Trends Analyt Chem 2016. [DOI: 10.1016/j.trac.2016.01.029] [Citation(s) in RCA: 13] [Impact Index Per Article: 1.4] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/20/2023]
|
16
|
Abstract
Mass spectrometry (MS) is a technique that can identify analytes on the basis of mass-to-charge (m/z) ratio. Although this technique has been used in research and specialized clinical laboratories for decades, however, in recent years, MS has been increasingly used in routine clinical laboratories. MS, especially when coupled to gas chromatography or liquid chromatography, provides very specific and often sensitive analysis of many analytes. Other advantages of MS include simultaneous analysis of multiple analytes (>100) and generally without need for specialized reagents. Commonly measured analytes by MS include drugs, hormones, and proteins.
Collapse
Affiliation(s)
- Uttam Garg
- Department of Pathology and Laboratory Medicine, Children's Mercy Hospitals and Clinics, 2401 Gillham Road, Kansas City, MO, 64108, USA.
- University of Missouri School of Medicine, Kansas City, MO, USA.
| | - Yan Victoria Zhang
- Department of Pathology and Laboratory Medicine, University of Rochester, Rochester, NY, USA
| |
Collapse
|
17
|
Garg U, Zhang YV. Mass Spectrometry in Clinical Laboratory: Applications in Therapeutic Drug Monitoring and Toxicology. Methods Mol Biol 2016; 1383:1-10. [PMID: 26660168 DOI: 10.1007/978-1-4939-3252-8_1] [Citation(s) in RCA: 13] [Impact Index Per Article: 1.4] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/13/2022]
Abstract
Mass spectrometry (MS) has been used in research and specialized clinical laboratories for decades as a very powerful technology to identify and quantify compounds. In recent years, application of MS in routine clinical laboratories has increased significantly. This is mainly due to the ability of MS to provide very specific identification, high sensitivity, and simultaneous analysis of multiple analytes (>100). The coupling of tandem mass spectrometry with gas chromatography (GC) or liquid chromatography (LC) has enabled the rapid expansion of this technology. While applications of MS are used in many clinical areas, therapeutic drug monitoring, drugs of abuse, and clinical toxicology are still the primary focuses of the field. It is not uncommon to see mass spectrometry being used in routine clinical practices for those applications.
Collapse
Affiliation(s)
- Uttam Garg
- Department of Pathology and Laboratory Medicine, Children's Mercy Hospitals and Clinics, 2401 Gillham Road, Kansas City, MO, USA.
| | - Yan Victoria Zhang
- Department of Pathology and Laboratory Medicine, University of Rochester, Rochester, NY, USA
| |
Collapse
|
18
|
Salivary cortisol and cortisone by LC–MS/MS: validation, reference intervals and diagnostic accuracy in Cushing's syndrome. Clin Chim Acta 2015; 451:247-51. [DOI: 10.1016/j.cca.2015.10.004] [Citation(s) in RCA: 70] [Impact Index Per Article: 7.0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/11/2015] [Revised: 09/08/2015] [Accepted: 10/05/2015] [Indexed: 01/17/2023]
|
19
|
Zhang YV, Rockwood A. Impact of automation on mass spectrometry. Clin Chim Acta 2015; 450:298-303. [DOI: 10.1016/j.cca.2015.08.027] [Citation(s) in RCA: 24] [Impact Index Per Article: 2.4] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/21/2015] [Revised: 08/13/2015] [Accepted: 08/30/2015] [Indexed: 12/18/2022]
|
20
|
|
21
|
Rugged and accurate quantitation of colchicine in human plasma to support colchicine poisoning monitoring by using turbulent-flow LC–MS/MS analysis. Bioanalysis 2013; 5:2889-96. [DOI: 10.4155/bio.13.258] [Citation(s) in RCA: 8] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/17/2022] Open
Abstract
Background: Colchicine is a common drug used in inflammatory diseases. The narrow therapeutic index requires fast and reliable techniques for its quantitation. An online, automated sample preparation using TurboFlow™ technology combined with triple-stage quadrupole MS detection was applied to identify colchicine in human plasma and follow intoxications. Methodology: Plasma samples (200 µl) were mixed with deuterated colchicine and protein precipitation ZnSO4 solutions. After centrifugation, supernatants were extracted onto a Cyclone P TurboFlow column and eluted onto a narrowbore Hypersil™ GOLD column with a methanol/water gradient. Analytes were monitored in SRM mode (positive electrospray). Results: Total run time was 9.5 min. Calibration curves ranged from 0.342 to 17.1 ng/ml, with significant linearity (R2 >0.99). Inter- and intra-assay precisions were <16.8% and accuracy was 84.4–110%. Conclusion: This method is suitable for monitoring intoxication in patients undergoing chronic treatment and is routinely applied to toxicological samples.
Collapse
|