1
|
Tahmasbi M, Capela M, Santos T, Mateus J, Ventura T, do Carmo Lopes M. Particular issues to be considered in small field dosimetry for TrueBeam STx commissioning. Appl Radiat Isot 2023; 202:111066. [PMID: 37865066 DOI: 10.1016/j.apradiso.2023.111066] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/09/2022] [Revised: 08/28/2023] [Accepted: 10/05/2023] [Indexed: 10/23/2023]
Abstract
This study aims to report the relevant issues concerning small fields in the commissioning of a TrueBeam STx for photon energies of 6MV, 10MV, 6FFF, and 10FFF. Percent depth doses, profiles, and field output factors were measured according to the beam model configuration of the treatment planning system. Multiple detectors were used based on the IAEA TRS-483 protocol as well as EBT3 radiochromic film. Analytical Anisotropic and Acuros XB algorithms, were configured and validated through basic dosimetry comparisons and end-to-end clinical tests.
Collapse
Affiliation(s)
- Marziyeh Tahmasbi
- Radiologic Technology Department, School of Allied Medical Sciences, Ahvaz Jundishapur University of Medical Sciences, Ahvaz, Iran; Medical Physics Department, Instituto Portugues de Oncologia Coimbra Francisco Gentil, E.P.E., Portugal.
| | - Miguel Capela
- Medical Physics Department, Instituto Portugues de Oncologia Coimbra Francisco Gentil, E.P.E., Portugal
| | - Tania Santos
- Medical Physics Department, Instituto Portugues de Oncologia Coimbra Francisco Gentil, E.P.E., Portugal
| | - Josefina Mateus
- Medical Physics Department, Instituto Portugues de Oncologia Coimbra Francisco Gentil, E.P.E., Portugal
| | - Tiago Ventura
- Medical Physics Department, Instituto Portugues de Oncologia Coimbra Francisco Gentil, E.P.E., Portugal
| | - Maria do Carmo Lopes
- Medical Physics Department, Instituto Portugues de Oncologia Coimbra Francisco Gentil, E.P.E., Portugal
| |
Collapse
|
2
|
Investigation of field output factors using IAEA-AAPM TRS-483 code of practice recommendations and Monte Carlo simulation for 6 MV photon beams. JOURNAL OF RADIOTHERAPY IN PRACTICE 2021. [DOI: 10.1017/s1460396921000662] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/07/2022]
Abstract
Abstract
Introduction:
This study aims to experimentally determine field output factors using the methodologies suggested by the IAEA-AAPM TRS-483 for small field dosimetry and compare with the calculation from Monte Carlo (MC) simulation.
Methods:
The IBA-CC01, Sun Nuclear EDGE and IBA-SFD detectors were employed to determine the uncorrected and the corrected field output factors for 6 MV photon beams. Measurements were performed at 100 cm source to axis distance, 10 cm depth in water, and the field sizes ranged from 1 × 1 to 10 × 10 cm2. The use of field output correction factors proposed by the TRS-483 was utilised to determine field output factors. The measured field output factors were compared to that calculated using the egs_chamber user code.
Results:
The decrease in the percentage standard deviation of the measured three detectors was observed after applying the field output correction factors. Measured field output factors using CC01 and EDGE detectors agreed with MC values within 3% for field sizes down to 1 × 1 cm2, except the SFD detector.
Conclusions:
The corrected field output factors agree with the calculation from MC, except the SFD detector. CC01 and EDGE are suitable for determining field output factors, while the SFD may need more implementation of the intermediate field method.
Collapse
|
3
|
Manavalan M, Durai M, Narayanasamy G, Stathakis S, Godson HF, Subramani V. Output factor measurements with multiple detectors in CyberKnife ® Robotic Radiosurgery System. J Cancer Res Ther 2021; 17:870-874. [PMID: 34528534 DOI: 10.4103/jcrt.jcrt_962_20] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/04/2022]
Abstract
Aim The aim of this study was to measure and compare the output factor (OF) of a CyberKnife Robotic Radiosurgery System with eight different small field detectors and validate with Technical Report Series (TRS) report 483. Background Accurate dosimetry of CyberKnife system is limited due to the challenges in small field dosimetry. OF is a vital dosimetric parameter used in the photon beam modeling and any error would affect the dose calculation accuracy. Materials and Methods In this study, the OF was measured with eight different small-field detectors for the 12 IRIS collimators at 800 mm SAD setup at 15 mm depth. The detectors used were PTW 31016 PinPoint 3D, IBA PFD shielded diode, IBA EFD unshielded diode, IBA SFD unshielded diode (stereotactic), PTW 60008 shielded diode, PTW 60012 unshielded diode, PTW 60018 unshielded diode (stereotactic), and PTW 60019 CVD diamond detector. OF was obtained after correcting for field output correction factors from IAEA TRS No. 483. Results The field OFs in CyberKnife are derived from the measured data by applying the correction factors from Table 23 in TRS 483 for the eight small field detectors. These field OFs matched within 2% of peer-reviewed published values. The range and standard deviation showed a decreasing trend with collimator diameter. Conclusion The field OF obtained after applying the appropriate correction factor from TRS 483 matched well with the peer-reviewed published OFs. The inter-detector variation showed a decreasing trend with increasing collimator field size. This study gives physicists confidence in measuring field OFs while using small field detectors mentioned in this work.
Collapse
Affiliation(s)
| | - Manigandan Durai
- Department of Radiation Oncology, The Medicity, Gurugram, Haryana, India
| | - Ganesh Narayanasamy
- Department of Radiation Oncology, University of Arkansas for Medical Sciences, Little Rock, AR, USA
| | | | - Henry Finlay Godson
- Research & Development Centre, Bharathiyar University, Coimbatore, Tamil Nadu, India
| | | |
Collapse
|
4
|
Yabsantia S, Suriyapee S, Phaisangittisakul N, Oonsiri S, Sanghangthum T, Mirzakhanian L, Heng VJ, Seuntjens J. Determination of field output correction factors of radiophotoluminescence glass dosimeter and CC01 ionization chamber and validation against IAEA-AAPM TRS-483 code of practice. Phys Med 2021; 88:167-174. [PMID: 34280729 DOI: 10.1016/j.ejmp.2021.07.004] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 05/26/2021] [Revised: 06/24/2021] [Accepted: 07/05/2021] [Indexed: 10/20/2022] Open
Abstract
PURPOSE To determine the field output correction factors of the radiophotoluminescence glass dosimeter (RPLGD) in parallel and perpendicular orientations with reference to CC01, the ionization chamber. METHODS The dose to a small water volume and the sensitive volume of the RPLGD and the IBA-CC01 were determined for 6-MV, 100-cm SAD, 10-cm depth using egs_chamber user-code. The RPLGD in perpendicular and parallel orientations to the beam axis were studied. The field output correction factors of each detector for 0.5 × 0.5 to 10 × 10 cm2 field sizes were determined. These field output correction factors were validated by comparing field output factors against data determined from IAEA-AAPM TRS-483 code of practice. RESULTS The field output correction factors of all detectors were within 5% for field sizes down to 0.8 × 0.8 cm2. For 0.5 × 0.5 cm2, the field output correction factors of CC01, RPLGD in perpendicular and parallel orientations differed from unity by 14%, 19%, and 5%, respectively. The percentage difference between field output factors determined using RPLGD and CC01 data, corrected using the field output correction factors determined in this work and measurements with CC01 data corrected using TRS-483, was less than 3% for all field sizes, except for the smallest field size of RPLGD in perpendicular orientation and the CC01. CONCLUSIONS The field output correction factors of RPLGD and CC01 are reported. The validation proves that RPLGD in parallel orientation combined with the field output correction factors is the most suitable for determining the field output factors for the smallest field used in this study.
Collapse
Affiliation(s)
- Sumalee Yabsantia
- Medical Physics Program, Department of Radiology, Faculty of Medicine, Chulalongkorn University, Bangkok, Thailand
| | - Sivalee Suriyapee
- Medical Physics Program, Department of Radiology, Faculty of Medicine, Chulalongkorn University, Bangkok, Thailand.
| | | | - Sornjarod Oonsiri
- Department of Radiation Oncology, King Chulalongkorn Memorial Hospital, Thai Red Cross Society, Bangkok, Thailand
| | - Taweap Sanghangthum
- Medical Physics Program, Department of Radiology, Faculty of Medicine, Chulalongkorn University, Bangkok, Thailand
| | - Lalageh Mirzakhanian
- Health Sciences North, Sudbury, Ontario, Canada; Northern Ontario School of Medicine, Sudbury, Ontario, Canada
| | - Veng Jean Heng
- Medical Physics Unit, McGill University, Montreal, Québec H3G 1A4, Canada
| | - Jan Seuntjens
- Medical Physics Unit, McGill University, Montreal, Québec H3G 1A4, Canada
| |
Collapse
|
5
|
García Balcaza V, Camp A, Badal A, Andersson M, Almen A, Ginjaume M, Duch MA. Fast Monte Carlo codes for occupational dosimetry in interventional radiology. Phys Med 2021; 85:166-174. [PMID: 34015619 DOI: 10.1016/j.ejmp.2021.05.012] [Citation(s) in RCA: 7] [Impact Index Per Article: 1.8] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 12/28/2020] [Revised: 04/21/2021] [Accepted: 05/08/2021] [Indexed: 10/21/2022] Open
Abstract
PURPOSE Interventional radiology techniques cause radiation exposure both to patient and personnel. The radiation dose to the operator is usually measured with dosimeters located at specific points above or below the lead aprons. The aim of this study is to develop and validate two fast Monte Carlo (MC) codes for radiation transport in order to improve the assessment of individual doses in interventional radiology. The proposed methodology reduces the number of required dosemeters and provides immediate dose results. METHODS Two fast MC simulation codes, PENELOPE/penEasyIR and MCGPU-IR, have been developed. Both codes have been validated by comparing fast MC calculations with the multipurpose PENELOPE MC code and with measurements during a realistic interventional procedure. RESULTS The new codes were tested with a computation time of about 120 s to estimate operator doses while a standard simulation needs several days to obtain similar uncertainties. When compared with the standard calculation in simple set-ups, MCGPU-IR tends to underestimate doses (up to 5%), while PENELOPE/penEasyIR overestimates them (up to 18%). When comparing both fast MC codes with experimental values in realistic set-ups, differences are within 25%. These differences are within accepted uncertainties in individual monitoring. CONCLUSION The study highlights the fact that computational dosimetry based on the use of fast MC codes can provide good estimates of the personal dose equivalent and overcome some of the limitations of occupational monitoring in interventional radiology. Notably, MCGPU-IR calculates both organ doses and effective dose, providing a better estimate of radiation risk.
Collapse
Affiliation(s)
- V García Balcaza
- Institut de Tècniques Energètiques, Universitat Politècnica de Catalunya (UPC), Barcelona 08028, Spain.
| | - A Camp
- Institut de Tècniques Energètiques, Universitat Politècnica de Catalunya (UPC), Barcelona 08028, Spain
| | - A Badal
- Division of Imaging, Diagnostics, and Software Reliability, OSEL, CDRH, U.S. Food and Drug Administration Silver Spring, Maryland, United States
| | - M Andersson
- Medical Radiation Physics, Department of Translational Medicine (ITM), Lund University, SE-205 02, Malmö, Sweden
| | - A Almen
- Medical Radiation Physics, Department of Translational Medicine (ITM), Lund University, SE-205 02, Malmö, Sweden
| | - M Ginjaume
- Institut de Tècniques Energètiques, Universitat Politècnica de Catalunya (UPC), Barcelona 08028, Spain
| | - M A Duch
- Institut de Tècniques Energètiques, Universitat Politècnica de Catalunya (UPC), Barcelona 08028, Spain
| |
Collapse
|
6
|
Muñoz L, Kron T, Petasecca M, Bucci J, Jackson M, Metcalfe P, Rosenfeld AB, Biasi G. Consistency of small-field dosimetry, on and off axis, in beam-matched linacs used for stereotactic radiosurgery. J Appl Clin Med Phys 2021; 22:185-193. [PMID: 33440049 PMCID: PMC7882112 DOI: 10.1002/acm2.13160] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/15/2020] [Revised: 12/08/2020] [Accepted: 12/17/2020] [Indexed: 11/24/2022] Open
Abstract
PURPOSE Stereotactic radiosurgery (SRS) can be delivered with a standard linear accelerator (linac). At institutions having more than one linac, beam matching is common practice. In the literature, there are indications that machine central axis (CAX) matching for broad fields does not guarantee matching of small fields with side ≤2 cm. There is no indication on how matching for broad fields on axis translates to matching small fields off axis. These are of interest to multitarget single-isocenter (MTSI) SRS planning and the present work addresses that gap in the literature. METHODS We used 6 MV flattening filter free (FFF) beams from four Elekta VersaHD® linacs equipped with an Agility™ multileaf collimator (MLC). The linacs were strictly matched for broad fields on CAX. We compared output factors (OPFs) and effective field size, measured concurrently using a novel 2D solid-state dosimeter "Duo" with a spatial resolution of 0.2 mm, in square and rectangular static fields with sides from 0.5 to 2 cm, either on axis or away from it by 5 to 15 cm. RESULTS Among the four linacs, OPF for fields ≥1 × 1 cm2 ranged 1.3% on CAX, whereas off axis a maximum range of 1.9% was observed at 15 cm. A larger variability in OPF was noted for the 0.5 × 0.5 cm2 field, with a range of 5.9% on CAX, which improved to a maximum of 2.3% moving off axis. Two linacs showed greater consistency with a range of 1.4% on CAX and 2.2% at 15 cm off axis. Between linacs, the effective field size varied by <0.04 cm in most cases, both on and off axis. Tighter matching was observed for linacs with a similar focal spot position. CONCLUSIONS Verification of small-field consistency for matched linacs used for SRS is an important task for dosimetric validation. A significant benefit of concurrent measurement of field size and OPF allowed for a comprehensive assessment using a novel diode array. Our study showed the four linacs, strictly matched for broad fields on CAX, were still matched down to a field size of 1 x 1 cm2 on and off axis.
Collapse
Affiliation(s)
- Luis Muñoz
- Genesiscare Flinders Private HospitalBedford ParkSAAustralia
- Centre for Medical Radiation PhysicsUniversity of WollongongNSWAustralia
| | - Tomas Kron
- Centre for Medical Radiation PhysicsUniversity of WollongongNSWAustralia
- Peter MacCallum Cancer CentreMelbourneVICAustralia
| | - Marco Petasecca
- Centre for Medical Radiation PhysicsUniversity of WollongongNSWAustralia
| | - Joseph Bucci
- St. George Cancer Care CentreSt George HospitalKogarahNSWAustralia
- Genesiscare Waratah Private HospitalHurstvilleNSWAustralia
| | - Michael Jackson
- Centre for Medical Radiation PhysicsUniversity of WollongongNSWAustralia
- University of New South WalesKensingtonNSWAustralia
| | - Peter Metcalfe
- Centre for Medical Radiation PhysicsUniversity of WollongongNSWAustralia
| | | | - Giordano Biasi
- Centre for Medical Radiation PhysicsUniversity of WollongongNSWAustralia
- Peter MacCallum Cancer CentreMelbourneVICAustralia
| |
Collapse
|
7
|
Martínez-Rovira I, Puxeu-Vaqué J, Prezado Y. Dose evaluation of Grid Therapy using a 6 MV flattening filter-free (FFF) photon beam: A Monte Carlo study. Med Phys 2017; 44:5378-5383. [PMID: 28736809 DOI: 10.1002/mp.12485] [Citation(s) in RCA: 5] [Impact Index Per Article: 0.6] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/21/2017] [Revised: 06/11/2017] [Accepted: 07/15/2017] [Indexed: 12/27/2022] Open
Abstract
PURPOSE Spatially fractionated radiotherapy is a strategy to overcome the main limitation of radiotherapy, i.e., the restrained normal tissue tolerances. A well-known example is Grid Therapy, which is currently performed at some hospitals using megavoltage photon beams delivered by Linacs. Grid Therapy has been successfully used in the management of bulky abdominal tumors with low toxicity. The aim of this work was to evaluate whether an improvement in therapeutic index in Grid Therapy can be obtained by implementing it in a flattening filter-free (FFF) Linac. The rationale behind is that the removal of the flattening filter shifts the beam energy spectrum towards lower energies and increase the photon fluence. Lower energies result in a reduction of lateral scattering and thus, to higher peak-to-valley dose ratios (PVDR) in normal tissues. In addition, the gain in fluence might allow using smaller beams leading a more efficient exploitation of dose-volume effects, and consequently, a better normal tissue sparing. METHODS Monte Carlo simulations were used to evaluate realistic dose distributions considering a 6 MV FFF photon beam from a standard medical Linac and a cerrobend mechanical collimator in different configurations: grid sizes of 0.3 × 0.3 cm2 , 0.5 × 0.5 cm2 , and 1 × 1 cm2 and a corresponding center-to-center (ctc) distance of 0.6, 1, and 2 cm, respectively (total field size of 10 × 10 cm2 ). As figure of merit, peak doses in depth, PVDR, output factors (OF), and penumbra values were assessed. RESULTS Dose at the entrance is slightly higher than in conventional Grid Therapy. However, it is compensated by the large PVDR obtained at the entrance, reaching a maximum of 35 for a grid size of 1 × 1 cm2 . Indeed, this grid size leads to very high PVDR values at all depths (≥ 10), which are much higher than in standard Grid Therapy. This may be beneficial for normal tissues but detrimental for tumor control, where a lower PVDR might be requested. In that case, higher valley doses in the tumor could be achieved by using an interlaced approach and/or adapting the ctc distance. The smallest grid size (0.3 × 0.3 cm2 ) leads to low PVDR at all depths, comparable to standard Grid Therapy. However, the use of very thin beams might increase the normal tissue tolerances with respect to the grid size commonly used (1 × 1 cm2 ). The gain in fluence provided by FFF implies that the important OF reduction (0.6) will not increase treatment time. Finally, the intermediate configuration (0.5 × 0.5 cm2 ) provides high PVDR in the first 5 cm, and comparable PVDR to previous Grid Therapy works at depth. Therefore, this configuration might allow increasing the normal tissue tolerances with respect to Grid Therapy thanks to the higher PVDR and thinner beams, while a similar tumor control could be expected. CONCLUSIONS The implementation of Grid Therapy in an FFF photon beam from medical Linac might lead to an improvement of the therapeutic index. Among the cases evaluated, a grid size of 0.5 × 0.5 cm2 (1-cm-ctc) is the most advantageous configuration from the physics point of view. Radiobiological experiments are needed to fully explore this new avenue and to confirm our results.
Collapse
Affiliation(s)
- Immaculada Martínez-Rovira
- Department of Physics, Ionizing Radiation Research Group (GRRI), Universitat Autònoma de Barcelona, Campus UAB, Avinguda de l'Eix Central, Edicifi C, Cerdanyola del Vallès, 08193, Barcelona, Spain.,Laboratoire d'Imagerie et Modélisation en Neurobiologie et Cancérologie (IMNC), Centre National de la Recherche Scientifique (CNRS), Campus universitaire, Bât. 440, 1er étage - 15 rue Georges Clemenceau, 91406, Orsay cedex, France
| | - Josep Puxeu-Vaqué
- Servei de Protecció Radiològica i Física Mèdica, Hospital Universitari Sant Joan de Reus, Avinguda del Dr. Josep Laporte 2, 43204, Reus, Tarragona, Spain.,Servei de Física Mèdica i Protecció Radiològica, Institut Catalá d'Oncologia (ICO), Avinguda de la Granvia 199-203, Hospitalet de Llobregat, 08908, Barcelona, Spain
| | - Yolanda Prezado
- Laboratoire d'Imagerie et Modélisation en Neurobiologie et Cancérologie (IMNC), Centre National de la Recherche Scientifique (CNRS), Campus universitaire, Bât. 440, 1er étage - 15 rue Georges Clemenceau, 91406, Orsay cedex, France
| |
Collapse
|