Task-based assessment on various optimization protocols of computed tomography Pulmonary Angiography examination. Radiat Phys Chem Oxf Engl 1993 2021. [DOI: 10.1016/j.radphyschem.2021.109692] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 02/07/2023]
|
2
|
Vegas-Sánchez-Ferrero G, Ramos-Llordén G, Estépar RSJ. Harmonization of in-plane resolution in CT using multiple reconstructions from single acquisitions. Med Phys 2021; 48:6941-6961. [PMID: 34432901 DOI: 10.1002/mp.15186] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/23/2020] [Revised: 07/19/2021] [Accepted: 08/03/2021] [Indexed: 11/10/2022] Open
Abstract
PURPOSE To providea methodology that removes the spatial variability of in-plane resolution using different CT reconstructions. The methodology does not require any training, sinogram, or specific reconstruction method. METHODS The methodology is formulated as a reconstruction problem. The desired sharp image is modeled as an unobservable variable to be estimated from an arbitrary number of observations with spatially variant resolution. The methodology comprises three steps: (1) density harmonization, which removes the density variability across reconstructions; (2) point spread function (PSF) estimation, which estimates a spatially variant PSF with arbitrary shape; (3) deconvolution, which is formulated as a regularized least squares problem. The assessment was performed with CT scans of phantoms acquired with three different Siemens scanners (Definition AS, Definition AS+, Drive). Four low-dose acquisitions reconstructed with backprojection and iterative methods were used for the resolution harmonization. A sharp, high-dose (HD) reconstruction was used as a validation reference. The different factors affecting the in-plane resolution (radial, angular, and longitudinal) were studied with regression analysis of the edge decay (between 10% and 90% of the edge spread function (ESF) amplitude). RESULTS Results showed that the in-plane resolution improves remarkably and the spatial variability is substantially reduced without compromising the noise characteristics. The modulated transfer function (MTF) also confirmed a pronounced increase in resolution. The resolution improvement was also tested by measuring the wall thickness of tubes simulating airways. In all scanners, the resolution harmonization obtained better performance than the HD, sharp reconstruction used as a reference (up to 50 percentage points). The methodology was also evaluated in clinical scans achieving a noise reduction and a clear improvement in thin-layered structures. The estimated ESF and MTF confirmed the resolution improvement. CONCLUSION We propose a versatile methodology to reduce the spatial variability of in-plane resolution in CT scans by leveraging different reconstructions available in clinical studies. The methodology does not require any sinogram, training, or specific reconstruction, and it is not limited to a fixed number of input images. Therefore, it can be easily adopted in multicenter studies and clinical practice. The results obtained with our resolution harmonization methodology evidence its suitability to reduce the spatially variant in-plane resolution in clinical CT scans without compromising the reconstruction's noise characteristics. We believe that the resolution increase achieved by our methodology may contribute in more accurate and reliable measurements of small structures such as vasculature, airways, and wall thickness.
Collapse
Affiliation(s)
- Gonzalo Vegas-Sánchez-Ferrero
- Applied ChestImaging Laboratory (ACIL), Department of Radiology, Brigham and Women's Hospital, Harvard Medical School, Boston, Massachusetts, USA
| | - Gabriel Ramos-Llordén
- Department of Radiology, Athinoula A. Martinos Center for Biomedical Imaging, Massachusetts General Hospital, Harvard Medical School, Boston, Massachusetts, USA
| | - Raúl San José Estépar
- Applied ChestImaging Laboratory (ACIL), Department of Radiology, Brigham and Women's Hospital, Harvard Medical School, Boston, Massachusetts, USA
| |
Collapse
|
3
|
Assessment of task-based image quality for abdominal CT protocols linked with national diagnostic reference levels. Eur Radiol 2021; 32:1227-1237. [PMID: 34327581 PMCID: PMC8794993 DOI: 10.1007/s00330-021-08185-1] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/11/2021] [Revised: 06/04/2021] [Accepted: 06/29/2021] [Indexed: 12/18/2022]
Abstract
Objectives To assess task-based image quality for two abdominal protocols on various CT scanners. To establish a relationship between diagnostic reference levels (DRLs) and task-based image quality. Methods A protocol for the detection of focal liver lesions was used to scan an anthropomorphic abdominal phantom containing 8- and 5-mm low-contrast (20 HU) spheres at five CTDIvol levels (4, 8, 12, 16, and 20 mGy) on 12 CTs. Another phantom with high-contrast calcium targets (200 HU) was scanned at 2, 4, 6, 10, and 15 mGy using a renal stones protocol on the same CTs. To assess the detectability, a channelized Hotelling observer was used for low-contrast targets and a non-prewhitening observer with an eye filter was used for high contrast targets. The area under the ROC curve and signal to noise ratio were used as figures of merit. Results For the detection of 8-mm spheres, the image quality reached a high level (mean AUC over all CTs higher than 0.95) at 11 mGy. For the detection of 5-mm spheres, the AUC never reached a high level of image quality. Variability between CTs was found, especially at low dose levels. For the search of renal stones, the AUC was nearly maximal even for the lowest dose level. Conclusions Comparable task-based image quality cannot be reached at the same dose level on all CT scanners. This variability implies the need for scanner-specific dose optimization. Key Points • There is an image quality variability for subtle low-contrast lesion detection in the clinically used dose range. • Diagnostic reference levels were linked with task-based image quality metrics. • There is a need for specific dose optimization for each CT scanner and clinical protocol.
Collapse
|
4
|
Acri G, Gurgone S, Iovane C, B Romeo M, Borzelli D, Testagrossa B. A Novel Phantom and a Dedicated Developed Software for Image Quality Controls in X-Ray Intraoral Devices. J Biomed Phys Eng 2021; 11:151-162. [PMID: 33937123 PMCID: PMC8064129 DOI: 10.31661/jbpe.v0i0.2001-1061] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/20/2020] [Accepted: 03/09/2020] [Indexed: 11/22/2022]
Abstract
Background: Periodic quality control (QC) procedures are important in order to guarantee the image quality of radiological equipment and are also conducted using phantoms simulating human body. Objective: To perform (QC) measurements in intraoral imaging devices, a new and simple phantom was manufactured. Besides, to simplify QC procedures, computerized LabView-based software has been devised, enabling determination of image quantitative parameters in real time or during post processing. Material and Methods: In this experimental study, the novel developed phantom consists of a Polymethyl methacrylate (PMMA) circular insert. It is able to perform a complete QC image program of X-ray intraoral equipment and also causes the evaluation of image uniformity, high and low contrast spatial resolution, image linearity and artefacts, with only two exposures. Results: Three raters analyzed the images using the LabView dedicated software and determined the quantitative and qualitative parameters in an innovative and accurate way. Statistical analysis evaluated the reliability of this study. Good accuracy of the quantitative and qualitative measurements for the different intraoral systems was obtained and no statistical differences were found using the inter-rater analysis. Conclusion: The achieved results and the related statistical analysis showed the validity of this methodology, which could be proposed as an alternative to the commonly adopted procedures, and suggested that the novel phantom, coupled with the LabView based software, could be considered as an effective tool to carry out a QC image program in a reproducible manner.
Collapse
Affiliation(s)
- Giuseppe Acri
- PhD, Department of Biomedical and Dental Sciences and Morphofunctional Imaging (BIOMORF), University of Messina, Italy
| | - Sergio Gurgone
- MSc, Department of Mathematical and Computational Sciences, Physics Sciences and Earth Sciences, (MIFT) University of Messina, Italy
| | | | - Marco B Romeo
- MSc, Forensic Science Investigation, Carabinieri Section Messina, Italy
| | - Daniele Borzelli
- PhD, Department of Biomedical and Dental Sciences and Morphofunctional Imaging (BIOMORF), University of Messina, Italy
| | - Barbara Testagrossa
- PhD, Department of Biomedical and Dental Sciences and Morphofunctional Imaging (BIOMORF), University of Messina, Italy
| |
Collapse
|
5
|
Barca P, Paolicchi F, Aringhieri G, Palmas F, Marfisi D, Fantacci ME, Caramella D, Giannelli M. A comprehensive assessment of physical image quality of five different scanners for head CT imaging as clinically used at a single hospital centre-A phantom study. PLoS One 2021; 16:e0245374. [PMID: 33444367 PMCID: PMC7808662 DOI: 10.1371/journal.pone.0245374] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/24/2020] [Accepted: 12/28/2020] [Indexed: 11/18/2022] Open
Abstract
Nowadays, given the technological advance in CT imaging and increasing heterogeneity in characteristics of CT scanners, a number of CT scanners with different manufacturers/technologies are often installed in a hospital centre and used by various departments. In this phantom study, a comprehensive assessment of image quality of 5 scanners (from 3 manufacturers and with different models) for head CT imaging, as clinically used at a single hospital centre, was hence carried out. Helical and/or sequential acquisitions of the Catphan-504 phantom were performed, using the scanning protocols (CTDIvol range: 54.7–57.5 mGy) employed by the staff of various Radiology/Neuroradiology departments of our institution for routine head examinations. CT image quality for each scanner/acquisition protocol was assessed through noise level, noise power spectrum (NPS), contrast-to-noise ratio (CNR), modulation transfer function (MTF), low contrast detectability (LCD) and non-uniformity index analyses. Noise values ranged from 3.5 HU to 5.7 HU across scanners/acquisition protocols. NPS curves differed in terms of peak position (range: 0.21–0.30 mm-1). A substantial variation of CNR values with scanner/acquisition protocol was observed for different contrast inserts. The coefficient of variation (standard deviation divided by mean value) of CNR values across scanners/acquisition protocols was 18.3%, 31.4%, 34.2%, 30.4% and 30% for teflon, delrin, LDPE, polystyrene and acrylic insert, respectively. An appreciable difference in MTF curves across scanners/acquisition protocols was revealed, with a coefficient of variation of f50%/f10% of MTF curves across scanners/acquisition protocols of 10.1%/7.4%. A relevant difference in LCD performance of different scanners/acquisition protocols was found. The range of contrast threshold for a typical object size of 3 mm was 3.7–5.8 HU. Moreover, appreciable differences in terms of NUI values (range: 4.1%-8.3%) were found. The analysis of several quality indices showed a non-negligible variability in head CT imaging capabilities across different scanners/acquisition protocols. This highlights the importance of a physical in-depth characterization of image quality for each CT scanner as clinically used, in order to optimize CT imaging procedures.
Collapse
Affiliation(s)
- Patrizio Barca
- Unit of Medical Physics, Pisa University Hospital “Azienda Ospedaliero-Universitaria Pisana”, Pisa, Italy
| | - Fabio Paolicchi
- Diagnostic and Interventional Radiology, University of Pisa, Pisa, Italy
| | - Giacomo Aringhieri
- Diagnostic and Interventional Radiology, University of Pisa, Pisa, Italy
| | | | - Daniela Marfisi
- Unit of Medical Physics, Pisa University Hospital “Azienda Ospedaliero-Universitaria Pisana”, Pisa, Italy
| | | | - Davide Caramella
- Diagnostic and Interventional Radiology, University of Pisa, Pisa, Italy
| | - Marco Giannelli
- Unit of Medical Physics, Pisa University Hospital “Azienda Ospedaliero-Universitaria Pisana”, Pisa, Italy
- * E-mail:
| |
Collapse
|
6
|
Task-based assessment of neck CT protocols using patient-mimicking phantoms-effects of protocol parameters on dose and diagnostic performance. Eur Radiol 2020; 31:3177-3186. [PMID: 33151393 PMCID: PMC8043932 DOI: 10.1007/s00330-020-07374-8] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/04/2020] [Revised: 08/18/2020] [Accepted: 10/05/2020] [Indexed: 11/25/2022]
Abstract
Objectives To assess how modifying multiple protocol parameters affects the dose and diagnostic performance of a neck CT protocol using patient-mimicking phantoms and task-based methods. Methods Six patient-mimicking neck phantoms containing hypodense lesions of 1 cm diameter and 30 HU contrast and one non-lesion phantom were examined with 36 CT protocols. All possible combinations of the following parameters were investigated: 100- and 120-kVp tube voltage; tube current modulation (TCM) noise levels of SD 7.5, 10, and 14; pitches of 0.637, 0.813, and 1.388; filtered back projection (FBP); and iterative reconstruction (AIDR 3D). Dose-length products (DLPs) and lesion detectability (assessed by 14 radiologists) were compared with the clinical standard protocol (120 kVp, TCM SD 7.5, 0.813 pitch, AIDR 3D). Results The DLP of the standard protocol was 25 mGy•cm; the area under the curve (AUC) was 0.839 (95%CI: 0.790–0.888). Combined effects of tube voltage reduction to 100 kVp and TCM noise level increase to SD 10 optimized protocol performance by improving dose (7.3 mGy•cm) and detectability (AUC 0.884, 95%CI: 0.844–0.924). Diagnostic performance was significantly affected by the TCM noise level at 120 kVp (AUC 0.821 at TCM SD 7.5 vs. 0.776 at TCM SD 14, p = 0.003), but not at 100-kVp tube voltage (AUC 0.839 at TCM SD 7.5 vs. 0.819 at TCM SD 14, p = 0.354), the reconstruction method at 100 kVp (AUC 0.854 for AIDR 3D vs. 0.806 for FBP, p < 0.001), but not at 120-kVp tube voltage (AUC 0.795 for AIDR 3D vs. 0.793 for FBP, p = 0.822), and the tube voltage for AIDR 3D reconstruction (p < 0.001), but not for FBP (p = 0.226). Conclusions Combined effects of 100-kVp tube voltage, TCM noise level of SD 10, a pitch of 0.813, and AIDR 3D resulted in an optimal neck protocol in terms of dose and diagnostic performance. Protocol parameters were subject to complex interactions, which created opportunities for protocol improvement. Key Points • A task-based approach using patient-mimicking phantoms was employed to optimize a CT system for neck imaging through systematic testing of protocol parameters. • Combined effects of 100-kVp tube voltage, TCM noise level of SD 10, a pitch of 0.813, and AIDR 3D reconstruction resulted in an optimal protocol in terms of dose and diagnostic performance. • Interactions of protocol parameters affect diagnostic performance and should be considered when optimizing CT techniques. Electronic supplementary material The online version of this article (10.1007/s00330-020-07374-8) contains supplementary material, which is available to authorized users.
Collapse
|
7
|
Nowak M, Carbonez P, Krauss M, Verdun FR, Damet J. Characterisation and mapping of scattered radiation fields in interventional radiology theatres. Sci Rep 2020; 10:18754. [PMID: 33127938 PMCID: PMC7599331 DOI: 10.1038/s41598-020-75257-5] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/05/2019] [Accepted: 09/30/2020] [Indexed: 12/02/2022] Open
Abstract
We used the Timepix3 hybrid pixel detector technology in order to determine the exposure of medical personnel to ionizing radiation in an interventional radiology room. We measured the energy spectra of the scattered radiation generated by the patient during X-ray image-guided interventional procedures. We performed measurements at different positions and heights within the theatre. We first observed a difference in fluence for each staff member. As expected, we found that the person closest to the X-ray tube is the most exposed while the least exposed staff member is positioned at the patient’s feet. Additionally, we observed a shift in energy from head to toe for practitioners, clearly indicating a non-homogenous energy exposure. The photon counting Timepix3 detector provides a new tool for radiation field characterisation that is easier-to-use and more compact than conventional X-ray spectrometers. The spectral information is particularly valuable for optimising the use of radiation protection gear and improving dosimetry surveillance programs. We also found the device very useful for training purposes to provide awareness and understanding about radiation protection principles among interventional radiology staff.
Collapse
Affiliation(s)
- M Nowak
- CERN, European Organization for Nuclear Research, Geneva, Switzerland. .,Institut of Radiation Physics, Lausanne University Hospital and University of Lausanne, Lausanne, Switzerland.
| | - P Carbonez
- CERN, European Organization for Nuclear Research, Geneva, Switzerland.,Department of Radiology, University of Otago, Christchurch, New Zealand
| | - M Krauss
- Department of Radiology, University of Otago, Christchurch, New Zealand.,Department of Interventional Radiology, Christchurch Hospital, Christchurch, New Zealand
| | - F R Verdun
- Institut of Radiation Physics, Lausanne University Hospital and University of Lausanne, Lausanne, Switzerland
| | - J Damet
- CERN, European Organization for Nuclear Research, Geneva, Switzerland.,Institut of Radiation Physics, Lausanne University Hospital and University of Lausanne, Lausanne, Switzerland.,Department of Radiology, University of Otago, Christchurch, New Zealand
| |
Collapse
|
8
|
Task-based characterization of a deep learning image reconstruction and comparison with filtered back-projection and a partial model-based iterative reconstruction in abdominal CT: A phantom study. Phys Med 2020; 76:28-37. [DOI: 10.1016/j.ejmp.2020.06.004] [Citation(s) in RCA: 39] [Impact Index Per Article: 9.8] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 03/02/2020] [Revised: 04/28/2020] [Accepted: 06/02/2020] [Indexed: 12/12/2022] Open
|
9
|
Padole AM, Sagar P, Westra SJ, Lim R, Nimkin K, Kalra MK, Gee MS, Rehani MM. Development and validation of image quality scoring criteria (IQSC) for pediatric CT: a preliminary study. Insights Imaging 2019; 10:95. [PMID: 31549234 PMCID: PMC6757090 DOI: 10.1186/s13244-019-0769-8] [Citation(s) in RCA: 17] [Impact Index Per Article: 3.4] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/09/2019] [Accepted: 07/12/2019] [Indexed: 12/11/2022] Open
Abstract
OBJECTIVE To develop and assess the value and limitations of an image quality scoring criteria (IQSC) for pediatric CT exams. METHODS IQSC was developed for subjective assessment of image quality using the scoring scale from 0 to 4, with 0 indicating desired anatomy or features not seen, 3 for adequate image quality, and 4 depicting higher than needed image quality. Pediatric CT examinations from 30 separate patients were selected, five each for routine chest, routine abdomen, kidney stone, appendicitis, craniosynostosis, and ventriculoperitoneal (VP) shunt. Five board-certified pediatric radiologists independently performed image quality evaluation using the proposed IQSC. The kappa statistics were used to assess the interobserver variability. RESULTS All five radiologists gave a score of 3 to two-third (67%) of all CT exams, followed by a score of 4 for 29% of CT exams, and 2 for 4% exams. The median image quality scores for all exams were 3 and the interobserver agreement among five readers (acceptable image quality [scores 3 or 4] vs sub-optimal image quality ([scores 1 and 2]) was moderate to very good (kappa 0.4-1). For all five radiologists, the lesion detection was adequate for all CT exams. CONCLUSIONS The image quality scoring criteria covering routine and some clinical indication-based imaging scenarios for pediatric CT examinations has potential to offer a simple and practical tool for assessing image quality with a reasonable degree of interobserver agreement. A more extensive and multi-centric study is recommended to establish wider usefulness of these criteria.
Collapse
Affiliation(s)
- Atul M Padole
- Department of Radiology, Massachusetts General Hospital, Harvard Medical School, 75 Cambridge Street, Suite 244, Boston, MA, 02114, USA
| | - Pallavi Sagar
- Department of Radiology, Massachusetts General Hospital, Harvard Medical School, 75 Cambridge Street, Suite 244, Boston, MA, 02114, USA
| | - Sjirk J Westra
- Department of Radiology, Massachusetts General Hospital, Harvard Medical School, 75 Cambridge Street, Suite 244, Boston, MA, 02114, USA
| | - Ruth Lim
- Department of Radiology, Massachusetts General Hospital, Harvard Medical School, 75 Cambridge Street, Suite 244, Boston, MA, 02114, USA
| | - Katherine Nimkin
- Department of Radiology, Massachusetts General Hospital, Harvard Medical School, 75 Cambridge Street, Suite 244, Boston, MA, 02114, USA
| | - Mannudeep K Kalra
- Department of Radiology, Massachusetts General Hospital, Harvard Medical School, 75 Cambridge Street, Suite 244, Boston, MA, 02114, USA
| | - Michael S Gee
- Department of Radiology, Massachusetts General Hospital, Harvard Medical School, 75 Cambridge Street, Suite 244, Boston, MA, 02114, USA
| | - Madan M Rehani
- Department of Radiology, Massachusetts General Hospital, Harvard Medical School, 75 Cambridge Street, Suite 244, Boston, MA, 02114, USA.
| |
Collapse
|
10
|
Aguet J, Becce F, Dunet V, Vlassenbroek A, Coche EE, Omoumi P. Optimizing radiation dose parameters in MDCT arthrography of the shoulder: illustration of basic concepts in a cadaveric study. Skeletal Radiol 2019; 48:1261-1268. [PMID: 30725159 DOI: 10.1007/s00256-019-3150-6] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.6] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 08/20/2018] [Revised: 12/11/2018] [Accepted: 01/07/2019] [Indexed: 02/02/2023]
Abstract
OBJECTIVE To determine in a cadaveric study the lowest achievable radiation dose and optimal tube potential generating diagnostic image quality in multidetector computed tomography (MDCT) arthrography of the shoulder. MATERIALS AND METHODS Six shoulders from three human cadavers were scanned using a 256-MDCT system after intra-articular injection of diluted iodinated contrast material. Using six decreasing radiation dose levels (CTDIvol: 20, 15, 10, 8, 6, and 4 mGy) and for each dose level, four decreasing tube potentials (140, 120, 100, and 80 kVp), image noise and contrast-to-noise ratio (CNR) were measured. Two independent and blinded observers assessed the overall diagnostic image quality, subjective amount of noise, and severity of artifacts according to a four-point scale. Influence of those MDCT data acquisition parameters on objective and subjective image quality was analyzed using the Kruskal-Wallis and Wilcoxon signed-rank tests, and pairwise comparisons were performed. RESULTS Multidetector CT protocols with radiation doses of 15 mGy or higher, combined with tube potentials of 100 kVp or higher, were equivalent in CNR to the reference 20 mGy-140 kVp protocol (all p ≥ 0.054). Above a CTDIvol of 10 mGy and a tube potential of 120 kVp, all protocols generated diagnostic image quality and subjective noise equivalent to the 20 mGy-140 kVp protocol (all p ≥ 0.22). CONCLUSIONS Diagnostic image quality in MDCT arthrography of the shoulder can be obtained with a radiation dose of 10 mGy at an optimal tube potential of 120 kVp, corresponding to a reduction of up to 50% compared with standard-dose protocols, and as high as 500% compared with reported protocols in the literature.
Collapse
Affiliation(s)
- Julien Aguet
- Department of Diagnostic and Interventional Radiology, Lausanne University Hospital and University of Lausanne, Rue du Bugnon 46, 1011, Lausanne, Switzerland
| | - Fabio Becce
- Department of Diagnostic and Interventional Radiology, Lausanne University Hospital and University of Lausanne, Rue du Bugnon 46, 1011, Lausanne, Switzerland
| | - Vincent Dunet
- Department of Diagnostic and Interventional Radiology, Lausanne University Hospital and University of Lausanne, Rue du Bugnon 46, 1011, Lausanne, Switzerland
| | | | - Emmanuel E Coche
- Department of Radiology and Medical Imaging, Cliniques Universitaires Saint-Luc, Université Catholique de Louvain, Avenue Hippocrate 10, 1200, Bruxelles, Belgium
| | - Patrick Omoumi
- Department of Diagnostic and Interventional Radiology, Lausanne University Hospital and University of Lausanne, Rue du Bugnon 46, 1011, Lausanne, Switzerland.
| |
Collapse
|
11
|
Yerly J, Becce F, van Heeswijk RB, Verdun FR, Gubian D, Meuli R, Stuber M. In vitro optimization and comparison of CT angiography versus radial cardiovascular magnetic resonance for the quantification of cross-sectional areas and coronary endothelial function. J Cardiovasc Magn Reson 2019; 21:11. [PMID: 30728035 PMCID: PMC6366062 DOI: 10.1186/s12968-019-0521-z] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.4] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/26/2018] [Accepted: 01/14/2019] [Indexed: 12/21/2022] Open
Abstract
BACKGROUND Our objectives were first to determine the optimal coronary computed tomography angiography (CTA) protocol for the quantification and detection of simulated coronary artery cross-sectional area (CSA) differences in vitro, and secondly to quantitatively compare the performance of the optimized CTA protocol with a previously validated radial coronary cardiovascular magnetic resonance (CMR) technique. METHODS 256-multidetector CTA and radial coronary CMR were used to obtain images of a custom in vitro resolution phantom simulating a range of physiological responses of coronary arteries to stress. CSAs were automatically quantified and compared with known nominal values to determine the accuracy, precision, signal-to-noise ratio (SNR), and circularity of CSA measurements, as well as the limit of detection (LOD) of CSA differences. Various iodine concentrations, radiation dose levels, tube potentials, and iterative image reconstruction algorithms (ASiR-V) were investigated to determine the optimal CTA protocol. The performance of the optimized CTA protocol was then compared with a radial coronary CMR method previously developed for endothelial function assessment under both static and moving conditions. RESULTS The iodine concentration, dose level, tube potential, and reconstruction algorithm all had significant effects (all p < 0.001) on the accuracy, precision, LOD, SNR, and circularity of CSA measurements with CTA. The best precision, LOD, SNR, and circularity with CTA were achieved with 6% iodine, 20 mGy, 100 kVp, and 90% ASiR-V. Compared with the optimized CTA protocol under static conditions, radial coronary CMR was less accurate (- 0.91 ± 0.13 mm2 vs. -0.35 ± 0.04 mm2, p < 0.001), but more precise (0.08 ± 0.02 mm2 vs. 0.21 ± 0.02 mm2, p < 0.001), and enabled the detection of significantly smaller CSA differences (0.16 ± 0.06 mm2 vs. 0.52 ± 0.04 mm2; p < 0.001; corresponding to CSA percentage differences of 2.3 ± 0.8% vs. 7.4 ± 0.6% for a 3-mm baseline diameter). The same results held true under moving conditions as CSA measurements with CMR were less affected by motion. CONCLUSIONS Radial coronary CMR was more precise and outperformed CTA for the specific task of detecting small CSA differences in vitro, and was able to reliably identify CSA changes an order of magnitude smaller than those reported for healthy physiological vasomotor responses of proximal coronary arteries. However, CTA yielded more accurate CSA measurements, which may prove useful in other clinical scenarios, such as coronary artery stenosis assessment.
Collapse
Affiliation(s)
- Jérôme Yerly
- Department of Diagnostic and Interventional Radiology, Lausanne University Hospital (CHUV and UNIL), Rue du Bugnon 46, Lausanne, 1011 VD Switzerland
- Center for Biomedical Imaging (CIBM), Lausanne, Switzerland
| | - Fabio Becce
- Department of Diagnostic and Interventional Radiology, Lausanne University Hospital (CHUV and UNIL), Rue du Bugnon 46, Lausanne, 1011 VD Switzerland
| | - Ruud B. van Heeswijk
- Department of Diagnostic and Interventional Radiology, Lausanne University Hospital (CHUV and UNIL), Rue du Bugnon 46, Lausanne, 1011 VD Switzerland
- Center for Biomedical Imaging (CIBM), Lausanne, Switzerland
| | - Francis R. Verdun
- Institute of Radiation Physics, Lausanne University Hospital (CHUV and UNIL), Lausanne, Switzerland
| | - Danilo Gubian
- Direction des Constructions, Ingénierie, Technique et Sécurité (CIT-S), Lausanne University Hospital (CHUV and UNIL), Lausanne, Switzerland
| | - Reto Meuli
- Department of Diagnostic and Interventional Radiology, Lausanne University Hospital (CHUV and UNIL), Rue du Bugnon 46, Lausanne, 1011 VD Switzerland
| | - Matthias Stuber
- Department of Diagnostic and Interventional Radiology, Lausanne University Hospital (CHUV and UNIL), Rue du Bugnon 46, Lausanne, 1011 VD Switzerland
- Center for Biomedical Imaging (CIBM), Lausanne, Switzerland
| |
Collapse
|
12
|
Task-Based Model Observer Assessment of A Partial Model-Based Iterative Reconstruction Algorithm in Thoracic Oncologic Multidetector CT. Sci Rep 2018; 8:17734. [PMID: 30531988 PMCID: PMC6286352 DOI: 10.1038/s41598-018-36045-4] [Citation(s) in RCA: 20] [Impact Index Per Article: 3.3] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/18/2018] [Accepted: 11/14/2018] [Indexed: 12/14/2022] Open
Abstract
To investigate the impact of a partial model-based iterative reconstruction (ASiR-V) on image quality in thoracic oncologic multidetector computed tomography (MDCT), using human and mathematical model observers. Twenty cancer patients examined with regular-dose thoracic-abdominal-pelvic MDCT were retrospectively included. Thoracic images reconstructed using a sharp kernel and filtered back-projection (reference) or ASiR-V (0-100%, 20% increments; follow-up) were analysed by three thoracic radiologists. Advanced quantitative physical metrics, including detectability indexes of simulated 4-mm-diameter solid non-calcified nodules and ground-glass opacities, were computed at regular and reduced doses using a custom-designed phantom. All three radiologists preferred higher ASiR-V levels (best = 80%). Increasing ASiR-V substantially decreased noise magnitude, with slight changes in noise texture. For high-contrast objects, changing the ASiR-V level had no major effect on spatial resolution; whereas for lower-contrast objects, increasing ASiR-V substantially decreased spatial resolution, more markedly at reduced dose. For both high- and lower-contrast pulmonary lesions, detectability remained excellent, regardless of ASiR-V and dose levels, and increased significantly with increasing ASiR-V levels (all p < 0.001). While high ASiR-V levels (80%) are recommended to detect solid non-calcified nodules and ground-glass opacities in regular-dose thoracic oncologic MDCT, care must be taken because, for lower-contrast pulmonary lesions, high ASiR-V levels slightly change noise texture and substantially decrease spatial resolution, more markedly at reduced dose.
Collapse
|
13
|
Task-based quantification of image quality using a model observer in abdominal CT: a multicentre study. Eur Radiol 2018; 28:5203-5210. [PMID: 29858638 PMCID: PMC6223860 DOI: 10.1007/s00330-018-5518-8] [Citation(s) in RCA: 15] [Impact Index Per Article: 2.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/09/2018] [Revised: 04/19/2018] [Accepted: 04/26/2018] [Indexed: 11/23/2022]
Abstract
Objective We investigated the variability in diagnostic information inherent in computed tomography (CT) images acquired at 68 different CT units, with the selected acquisition protocols aiming to answer the same clinical question. Methods An anthropomorphic abdominal phantom with two optional rings was scanned on 68 CT systems from 62 centres using the local clinical acquisition parameters of the portal venous phase for the detection of focal liver lesions. Low-contrast detectability (LCD) was assessed objectively with channelised Hotelling observer (CHO) using the receiver operating characteristic (ROC) paradigm. For each lesion size, the area under the ROC curve (AUC) was calculated and considered as a figure of merit. The volume computed tomography dose index (CTDIvol) was used to indicate radiation dose exposure. Results The median CTDIvol used was 5.8 mGy, 10.5 mGy and 16.3 mGy for the small, medium and large phantoms, respectively. The median AUC obtained from clinical CT protocols was 0.96, 0.90 and 0.83 for the small, medium and large phantoms, respectively. Conclusions Our study used a model observer to highlight the difference in image quality levels when dealing with the same clinical question. This difference was important and increased with growing phantom size, which generated large variations in patient exposure. In the end, a standardisation initiative may be launched to ensure comparable diagnostic information for well-defined clinical questions. The image quality requirements, related to the clinical question to be answered, should be the starting point of patient dose optimisation. Key Points • Model observers enable to assess image quality objectively based on clinical tasks. • Objective image quality assessment should always include several patient sizes. • Clinical diagnostic image quality should be the starting point for patient dose optimisation. • Dose optimisation by applying DRLs only is insufficient for ensuring clinical requirements.
Collapse
|
14
|
Effects of various generations of iterative CT reconstruction algorithms on low-contrast detectability as a function of the effective abdominal diameter: A quantitative task-based phantom study. Phys Med 2018; 48:111-118. [DOI: 10.1016/j.ejmp.2018.04.006] [Citation(s) in RCA: 26] [Impact Index Per Article: 4.3] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 12/28/2017] [Revised: 04/05/2018] [Accepted: 04/07/2018] [Indexed: 11/24/2022] Open
|