1
|
Pautasso JJ, Michielsen K, Sechopoulos I. Technical note: Characterization, validation, and spectral optimization of a dedicated breast CT system for contrast-enhanced imaging. Med Phys 2024; 51:3322-3333. [PMID: 38597897 DOI: 10.1002/mp.17069] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/08/2023] [Revised: 04/01/2024] [Accepted: 04/01/2024] [Indexed: 04/11/2024] Open
Abstract
BACKGROUND The development of a new imaging modality, such as 4D dynamic contrast-enhanced dedicated breast CT (4D DCE-bCT), requires optimization of the acquisition technique, particularly within the 2D contrast-enhanced imaging modality. Given the extensive parameter space, cascade-systems analysis is commonly used for such optimization. PURPOSE To implement and validate a parallel-cascaded model for bCT, focusing on optimizing and characterizing system performance in the projection domain to enhance the quality of input data for image reconstruction. METHODS A parallel-cascaded system model of a state-of-the-art bCT system was developed and model predictions of the presampled modulation transfer function (MTF) and the normalized noise power spectrum (NNPS) were compared with empirical data collected in the projection domain. Validation was performed using the default settings of 49 kV with 1.5 mm aluminum filter and at 65 kV and 0.257 mm copper filter. A 10 mm aluminum plate was added to replicate the breast attenuation. Air kerma at the isocenter was measured at different tube current levels. Discrepancies between the measured projection domain metrics and model-predicted values were quantified using percentage error and coefficient of variation (CoV) for MTF and NNPS, respectively. The optimal filtration was for a 5 mm iodine disk detection task at 49, 55, 60, and 65 kV. The detectability index was calculated for the default aluminum filtration and for copper thicknesses ranging from 0.05 to 0.4 mm. RESULTS At 49 kV, MTF errors were +5.1% and -5.1% at 1 and 2 cycles/mm, respectively; NNPS CoV was 5.3% (min = 3.7%; max = 8.5%). At 65 kV, MTF errors were -0.8% and -3.2%; NNPS CoV was 13.1% (min = 11.4%; max = 16.9%). Air kerma output was linear, with 11.67 µGy/mA (R2 = 0.993) and 19.14 µGy/mA (R2 = 0.996) at 49 and 65 kV, respectively. For iodine detection, a 0.25 mm-thick copper filter at 65 kV was found optimal, outperforming the default technique by 90%. CONCLUSION The model accurately predicts bCT system performance, specifically in the projection domain, under varied imaging conditions, potentially contributing to the enhancement of 2D contrast-enhanced imaging in 4D DCE-bCT.
Collapse
Affiliation(s)
- Juan J Pautasso
- Department of Medical Imaging, Radboud University Medical Center, Nijmegen, The Netherlands
| | - Koen Michielsen
- Department of Medical Imaging, Radboud University Medical Center, Nijmegen, The Netherlands
| | - Ioannis Sechopoulos
- Department of Medical Imaging, Radboud University Medical Center, Nijmegen, The Netherlands
- Dutch Expert Centre for Screening (LRCB), Nijmegen, The Netherlands
- Technical Medical Centre, University of Twente, Enschede, The Netherlands
| |
Collapse
|
2
|
Zhu Y, Ma Y, Zhai Z, Liu A, Wang Y, Zhang Y, Li H, Zhao M, Han P, Yin L, He N, Wu Y, Sechopoulos I, Ye Z, Caballo M. Radiomics in cone-beam breast CT for the prediction of axillary lymph node metastasis in breast cancer: a multi-center multi-device study. Eur Radiol 2024; 34:2576-2589. [PMID: 37782338 DOI: 10.1007/s00330-023-10256-4] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/04/2022] [Revised: 07/09/2023] [Accepted: 07/30/2023] [Indexed: 10/03/2023]
Abstract
OBJECTIVES To develop a radiomics model in contrast-enhanced cone-beam breast CT (CE-CBBCT) for preoperative prediction of axillary lymph node (ALN) status and metastatic burden of breast cancer. METHODS Two hundred and seventy-four patients who underwent CE-CBBCT examination with two scanners between 2012 and 2021 from two institutions were enrolled. The primary tumor was annotated in each patient image, from which 1781 radiomics features were extracted with PyRadiomics. After feature selection, support vector machine models were developed to predict ALN status and metastatic burden. To avoid overfitting on a specific patient subset, 100 randomly stratified splits were made to assign the patients to either training/fine-tuning or test set. Area under the receiver operating characteristic curve (AUC) of these radiomics models was compared to those obtained when training the models only with clinical features and combined clinical-radiomics descriptors. Ground truth was established by histopathology. RESULTS One hundred and eighteen patients had ALN metastasis (N + (≥ 1)). Of these, 74 had low burden (N + (1~2)) and 44 high burden (N + (≥ 3)). The remaining 156 patients had none (N0). AUC values across the 100 test repeats in predicting ALN status (N0/N + (≥ 1)) were 0.75 ± 0.05 (0.67~0.93, radiomics model), 0.68 ± 0.07 (0.53~0.85, clinical model), and 0.74 ± 0.05 (0.67~0.88, combined model). For metastatic burden prediction (N + (1~2)/N + (≥ 3)), AUC values were 0.65 ± 0.10 (0.50~0.88, radiomics model), 0.55 ± 0.10 (0.40~0.80, clinical model), and 0.64 ± 0.09 (0.50~0.90, combined model), with all the ranges spanning 0.5. In both cases, the radiomics model was significantly better than the clinical model (both p < 0.01) and comparable with the combined model (p = 0.56 and 0.64). CONCLUSIONS Radiomics features of primary tumors could have potential in predicting ALN metastasis in CE-CBBCT imaging. CLINICAL RELEVANCE STATEMENT The findings support potential clinical use of radiomics for predicting axillary lymph node metastasis in breast cancer patients and addressing the limited axilla coverage of cone-beam breast CT. KEY POINTS • Contrast-enhanced cone-beam breast CT-based radiomics could have potential to predict N0 vs. N + (≥ 1) and, to a limited extent, N + (1~2) vs. N + (≥ 3) from primary tumor, and this could help address the limited axilla coverage, pending future verifications on larger cohorts. • The average AUC of radiomics and combined models was significantly higher than that of clinical models but showed no significant difference between themselves. • Radiomics features descriptive of tumor texture were found informative on axillary lymph node status, highlighting a higher heterogeneity for tumor with positive axillary lymph node.
Collapse
Affiliation(s)
- Yueqiang Zhu
- Department of Radiology, Tianjin Medical University Cancer Institute and Hospital; National Clinical Research Center for Cancer; Tianjin's Clinical Research Center for Cancer; Key Laboratory of Cancer Prevention and Therapy, Tianjin; Key Laboratory of Breast Cancer Prevention and Therapy, Tianjin Medical University, Ministry of Education, Huan-Hu-Xi Road, Ti-Yuan-Bei, Hexi District, Tianjin, 300060, China
- Department of Medical Imaging, Radboud University Medical Center, PO Box 9101, Nijmegen, 6500 HB, The Netherlands
| | - Yue Ma
- Department of Radiology, Tianjin Medical University Cancer Institute and Hospital; National Clinical Research Center for Cancer; Tianjin's Clinical Research Center for Cancer; Key Laboratory of Cancer Prevention and Therapy, Tianjin; Key Laboratory of Breast Cancer Prevention and Therapy, Tianjin Medical University, Ministry of Education, Huan-Hu-Xi Road, Ti-Yuan-Bei, Hexi District, Tianjin, 300060, China
| | - Zhenzhen Zhai
- Department of Radiology, The Fifth Affiliated Hospital of Sun Yat-Sen University, Mei-Hua-Dong Road, Xiangzhou District, Zhuhai, 519000, China
| | - Aidi Liu
- Department of Radiology, Tianjin Medical University Cancer Institute and Hospital; National Clinical Research Center for Cancer; Tianjin's Clinical Research Center for Cancer; Key Laboratory of Cancer Prevention and Therapy, Tianjin; Key Laboratory of Breast Cancer Prevention and Therapy, Tianjin Medical University, Ministry of Education, Huan-Hu-Xi Road, Ti-Yuan-Bei, Hexi District, Tianjin, 300060, China
| | - Yafei Wang
- Department of Radiology, Tianjin Medical University Cancer Institute and Hospital; National Clinical Research Center for Cancer; Tianjin's Clinical Research Center for Cancer; Key Laboratory of Cancer Prevention and Therapy, Tianjin; Key Laboratory of Breast Cancer Prevention and Therapy, Tianjin Medical University, Ministry of Education, Huan-Hu-Xi Road, Ti-Yuan-Bei, Hexi District, Tianjin, 300060, China
| | - Yuwei Zhang
- Department of Radiology, Tianjin Medical University Cancer Institute and Hospital; National Clinical Research Center for Cancer; Tianjin's Clinical Research Center for Cancer; Key Laboratory of Cancer Prevention and Therapy, Tianjin; Key Laboratory of Breast Cancer Prevention and Therapy, Tianjin Medical University, Ministry of Education, Huan-Hu-Xi Road, Ti-Yuan-Bei, Hexi District, Tianjin, 300060, China
| | - Haijie Li
- Department of Radiology, Tianjin Medical University Cancer Institute and Hospital; National Clinical Research Center for Cancer; Tianjin's Clinical Research Center for Cancer; Key Laboratory of Cancer Prevention and Therapy, Tianjin; Key Laboratory of Breast Cancer Prevention and Therapy, Tianjin Medical University, Ministry of Education, Huan-Hu-Xi Road, Ti-Yuan-Bei, Hexi District, Tianjin, 300060, China
| | - Mengran Zhao
- Department of Radiology, Tianjin Medical University Cancer Institute and Hospital; National Clinical Research Center for Cancer; Tianjin's Clinical Research Center for Cancer; Key Laboratory of Cancer Prevention and Therapy, Tianjin; Key Laboratory of Breast Cancer Prevention and Therapy, Tianjin Medical University, Ministry of Education, Huan-Hu-Xi Road, Ti-Yuan-Bei, Hexi District, Tianjin, 300060, China
| | - Peng Han
- Department of Radiology, Tianjin Medical University Cancer Institute and Hospital; National Clinical Research Center for Cancer; Tianjin's Clinical Research Center for Cancer; Key Laboratory of Cancer Prevention and Therapy, Tianjin; Key Laboratory of Breast Cancer Prevention and Therapy, Tianjin Medical University, Ministry of Education, Huan-Hu-Xi Road, Ti-Yuan-Bei, Hexi District, Tianjin, 300060, China
| | - Lu Yin
- Department of Radiology, Tianjin Medical University Cancer Institute and Hospital; National Clinical Research Center for Cancer; Tianjin's Clinical Research Center for Cancer; Key Laboratory of Cancer Prevention and Therapy, Tianjin; Key Laboratory of Breast Cancer Prevention and Therapy, Tianjin Medical University, Ministry of Education, Huan-Hu-Xi Road, Ti-Yuan-Bei, Hexi District, Tianjin, 300060, China
| | - Ni He
- Department of Medical Imaging and Image-guided Therapy, Sun Yat-Sen University Cancer Center, State Key Laboratory of Oncology in South China, Collaborative Innovation Center for Cancer Medicine, Dong-Feng-Dong Road, Yuexiu District, Guangzhou, 510060, China
| | - Yaopan Wu
- Department of Medical Imaging and Image-guided Therapy, Sun Yat-Sen University Cancer Center, State Key Laboratory of Oncology in South China, Collaborative Innovation Center for Cancer Medicine, Dong-Feng-Dong Road, Yuexiu District, Guangzhou, 510060, China
| | - Ioannis Sechopoulos
- Department of Medical Imaging, Radboud University Medical Center, PO Box 9101, Nijmegen, 6500 HB, The Netherlands
- Dutch Expert Center for Screening (LRCB), PO Box 6873, Nijmegen, 6503 GJ, The Netherlands
- Technical Medicine Centre, University of Twente, PO Box 217, Enschede, 7500 AE, The Netherlands
| | - Zhaoxiang Ye
- Department of Radiology, Tianjin Medical University Cancer Institute and Hospital; National Clinical Research Center for Cancer; Tianjin's Clinical Research Center for Cancer; Key Laboratory of Cancer Prevention and Therapy, Tianjin; Key Laboratory of Breast Cancer Prevention and Therapy, Tianjin Medical University, Ministry of Education, Huan-Hu-Xi Road, Ti-Yuan-Bei, Hexi District, Tianjin, 300060, China.
| | - Marco Caballo
- Department of Medical Imaging, Radboud University Medical Center, PO Box 9101, Nijmegen, 6500 HB, The Netherlands
| |
Collapse
|
3
|
Li D, Makeev A, Glick SJ. 4D digital anthropomorphic breast phantom for iodinated contrast-enhanced imaging. J Med Imaging (Bellingham) 2023; 10:S22403. [PMID: 36910740 PMCID: PMC10005817 DOI: 10.1117/1.jmi.10.s2.s22403] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/15/2022] [Accepted: 02/13/2023] [Indexed: 03/12/2023] Open
Abstract
Purpose Differentiating between benign and malignant masses is one of the biggest challenges in breast imaging. The challenge is ingrained in the similarity of the attenuation coefficients between different types of lesion tissues and fibroglandular tissues. Contrast-enhanced imaging techniques can take advantage of the differing metabolism in different tissues, therefore, potentially allowing better differentiation of malignant and benign lesions. To facilitate the development and optimization of such technologies, we propose a fully digital 4D phantom that features time-varying enhancement patterns for different tissue types. Approach The 4D model is based on a static, anthropomorphic 3D digital breast phantom. Masses inserted into the 3D phantom are based on a previously published model. Physiological parameters that capture the key characteristics of masses, e.g., wash-in and wash-out rates indicating metabolic level, are employed in the model to simulate fundamental features for categorizing mass types. The two-compartmental model, a well-known model in the field of pharmacokinetics, is used to depict the diffusion process of the contrast agent. Two methods are proposed to allow for the simulations of lesions with necrotic cores of varying shapes and sizes. Results The fourth dimension of the phantom models different time-varying enhancement patterns for different materials including fibroglandular tissue and lesion tissue. Metabolic characteristics of mass models can be adjusted to provide different enhancement patterns. The parameters of the 4D phantom can also be adjusted to fit different scenarios. The usage of the phantom is demonstrated by simulating mammograms at different time frames. Conclusion A 4D digital anthropomorphic breast phantom that models different time-varying contrast enhancement patterns is presented. This phantom could be an integral tool for use in in silico trials to assess image quality of iodinated contrast-enhanced mammography, digital breast tomosynthesis, and breast computed tomography systems.
Collapse
Affiliation(s)
- Dan Li
- Food and Drug Administration, Silver Spring, Maryland, United States
| | - Andrey Makeev
- Food and Drug Administration, Silver Spring, Maryland, United States
| | - Stephen J. Glick
- Food and Drug Administration, Silver Spring, Maryland, United States
| |
Collapse
|
4
|
Zeng D, Zeng C, Zeng Z, Li S, Deng Z, Chen S, Bian Z, Ma J. Basis and current state of computed tomography perfusion imaging: a review. Phys Med Biol 2022; 67. [PMID: 35926503 DOI: 10.1088/1361-6560/ac8717] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/17/2021] [Accepted: 08/04/2022] [Indexed: 12/30/2022]
Abstract
Computed tomography perfusion (CTP) is a functional imaging that allows for providing capillary-level hemodynamics information of the desired tissue in clinics. In this paper, we aim to offer insight into CTP imaging which covers the basics and current state of CTP imaging, then summarize the technical applications in the CTP imaging as well as the future technological potential. At first, we focus on the fundamentals of CTP imaging including systematically summarized CTP image acquisition and hemodynamic parameter map estimation techniques. A short assessment is presented to outline the clinical applications with CTP imaging, and then a review of radiation dose effect of the CTP imaging on the different applications is presented. We present a categorized methodology review on known and potential solvable challenges of radiation dose reduction in CTP imaging. To evaluate the quality of CTP images, we list various standardized performance metrics. Moreover, we present a review on the determination of infarct and penumbra. Finally, we reveal the popularity and future trend of CTP imaging.
Collapse
Affiliation(s)
- Dong Zeng
- School of Biomedical Engineering, Southern Medical University, Guangdong 510515, China; and Guangzhou Key Laboratory of Medical Radiation Imaging and Detection Technology, Southern Medical University, Guangdong 510515, People's Republic of China
| | - Cuidie Zeng
- School of Biomedical Engineering, Southern Medical University, Guangdong 510515, China; and Guangzhou Key Laboratory of Medical Radiation Imaging and Detection Technology, Southern Medical University, Guangdong 510515, People's Republic of China
| | - Zhixiong Zeng
- School of Biomedical Engineering, Southern Medical University, Guangdong 510515, China; and Guangzhou Key Laboratory of Medical Radiation Imaging and Detection Technology, Southern Medical University, Guangdong 510515, People's Republic of China
| | - Sui Li
- School of Biomedical Engineering, Southern Medical University, Guangdong 510515, China; and Guangzhou Key Laboratory of Medical Radiation Imaging and Detection Technology, Southern Medical University, Guangdong 510515, People's Republic of China
| | - Zhen Deng
- Department of Neurology, Nanfang Hospital, Southern Medical University, Guangdong 510515, People's Republic of China
| | - Sijin Chen
- Department of Medical Imaging Center, Nanfang Hospital, Southern Medical University, Guangdong 510515, People's Republic of China
| | - Zhaoying Bian
- School of Biomedical Engineering, Southern Medical University, Guangdong 510515, China; and Guangzhou Key Laboratory of Medical Radiation Imaging and Detection Technology, Southern Medical University, Guangdong 510515, People's Republic of China
| | - Jianhua Ma
- School of Biomedical Engineering, Southern Medical University, Guangdong 510515, China; and Guangzhou Key Laboratory of Medical Radiation Imaging and Detection Technology, Southern Medical University, Guangdong 510515, People's Republic of China
| |
Collapse
|
5
|
Henze Bancroft L, Holmes J, Bosca-Harasim R, Johnson J, Wang P, Korosec F, Block W, Strigel R. An Anthropomorphic Digital Reference Object (DRO) for Simulation and Analysis of Breast DCE MRI Techniques. Tomography 2022; 8:1005-1023. [PMID: 35448715 PMCID: PMC9031444 DOI: 10.3390/tomography8020081] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/17/2022] [Revised: 03/11/2022] [Accepted: 03/14/2022] [Indexed: 11/29/2022] Open
Abstract
Advances in accelerated magnetic resonance imaging (MRI) continue to push the bounds on achievable spatial and temporal resolution while maintaining a clinically acceptable image quality. Validation tools, including numerical simulations, are needed to characterize the repeatability and reproducibility of such methods for use in quantitative imaging applications. We describe the development of a simulation framework for analyzing and optimizing accelerated MRI acquisition and reconstruction techniques used in dynamic contrast enhanced (DCE) breast imaging. The simulation framework, in the form of a digital reference object (DRO), consists of four modules that control different aspects of the simulation, including the appearance and physiological behavior of the breast tissue as well as the MRI acquisition settings, to produce simulated k-space data for a DCE breast exam. The DRO design and functionality are described along with simulation examples provided to show potential applications of the DRO. The included simulation results demonstrate the ability of the DRO to simulate a variety of effects including the creation of simulated lesions, tissue enhancement modeled by the generalized kinetic model, T1-relaxation, fat signal precession and saturation, acquisition SNR, and changes in temporal resolution.
Collapse
Affiliation(s)
- Leah Henze Bancroft
- Department of Radiology, University of Wisconsin-Madison, 600 Highland Ave, Madison, WI 53792, USA; (J.H.); (J.J.); (F.K.); (W.B.); (R.S.)
- Correspondence:
| | - James Holmes
- Department of Radiology, University of Wisconsin-Madison, 600 Highland Ave, Madison, WI 53792, USA; (J.H.); (J.J.); (F.K.); (W.B.); (R.S.)
- Department of Radiology, University of Iowa, 169 Newton Road, Iowa City, IA 52333, USA
- Holden Comprehensive Cancer Center, University of Iowa, 169 Newton Road, Iowa City, IA 52333, USA
| | - Ryan Bosca-Harasim
- Department of Imaging Physics, Sanford Health, 801 Broadway North, Fargo, ND 58102, USA;
- Department of Medical Physics, University of Wisconsin-Madison, 1111 Highland Avenue, Madison, WI 53705, USA;
| | - Jacob Johnson
- Department of Radiology, University of Wisconsin-Madison, 600 Highland Ave, Madison, WI 53792, USA; (J.H.); (J.J.); (F.K.); (W.B.); (R.S.)
| | - Pingni Wang
- Department of Medical Physics, University of Wisconsin-Madison, 1111 Highland Avenue, Madison, WI 53705, USA;
| | - Frank Korosec
- Department of Radiology, University of Wisconsin-Madison, 600 Highland Ave, Madison, WI 53792, USA; (J.H.); (J.J.); (F.K.); (W.B.); (R.S.)
- Department of Medical Physics, University of Wisconsin-Madison, 1111 Highland Avenue, Madison, WI 53705, USA;
| | - Walter Block
- Department of Radiology, University of Wisconsin-Madison, 600 Highland Ave, Madison, WI 53792, USA; (J.H.); (J.J.); (F.K.); (W.B.); (R.S.)
- Department of Medical Physics, University of Wisconsin-Madison, 1111 Highland Avenue, Madison, WI 53705, USA;
- Department of Biomedical Engineering, University of Wisconsin, 1415 Engineering Drive, Madison, WI 53706, USA
| | - Roberta Strigel
- Department of Radiology, University of Wisconsin-Madison, 600 Highland Ave, Madison, WI 53792, USA; (J.H.); (J.J.); (F.K.); (W.B.); (R.S.)
- Department of Medical Physics, University of Wisconsin-Madison, 1111 Highland Avenue, Madison, WI 53705, USA;
- Carbone Cancer Center, University of Wisconsin, 600 Highland Avenue, Madison, WI 53792, USA
| |
Collapse
|
6
|
Barufaldi B, Vent TL, Bakic PR, Maidment ADA. Computer Simulations of Case Difficulty in Digital Breast Tomosynthesis Using Virtual Clinical Trials. Med Phys 2022; 49:2220-2232. [PMID: 35212403 DOI: 10.1002/mp.15553] [Citation(s) in RCA: 6] [Impact Index Per Article: 3.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/19/2021] [Revised: 02/07/2022] [Accepted: 02/13/2022] [Indexed: 11/10/2022] Open
Abstract
PURPOSE Virtual clinical trials (VCTs) require computer simulations of representative patients and images to evaluate and compare changes in performance of imaging technologies. The simulated images are usually interpreted by model observers whose performance depends upon the selection of imaging cases used in training evaluation models. This work proposes an efficient method to simulate and calibrate soft tissue lesions, which matches the detectability threshold of virtual and human readings. METHODS Anthropomorphic breast phantoms were used to evaluate the simulation of four mass models (I-IV) that vary in shape and composition of soft tissue. Ellipsoidal (I) and spiculated (II-IV) masses were simulated using composite voxels with partial volumes. Digital breast tomosynthesis projections and reconstructions of a clinical system were simulated. Channelized Hotelling observers (CHOs) were evaluated using reconstructed slices of masses that varied in shape, composition, and density of surrounded tissue. The detectability threshold of each mass model was evaluated using receiver operating characteristic (ROC) curves calculated with the CHO's scores. RESULTS The area under the curve (AUC) of each calibrated mass model were within the 95% confidence interval (mean AUC [95% CI]) reported in a previous reader study (0.93 [0.89, 0.97]). The mean AUC [95% CI] obtained were 0.94 [0.93, 0.96], 0.92 [0.90, 0.93], 0.92 [0.90, 0.94], 0.93 [0.92, 0.95] for models I to IV, respectively. The mean AUC results varied substantially as a function of shape, composition, and density of surrounded tissue. CONCLUSIONS For successful VCTs, lesions composed of soft tissue should be calibrated to simulate imaging cases that match the case difficulty predicted by human readers. Lesion composition, shape, and size are parameters that should be carefully selected to calibrate VCTs. This article is protected by copyright. All rights reserved.
Collapse
Affiliation(s)
- Bruno Barufaldi
- Department of Radiology, University of Pennsylvania, Philadelphia, PA, 19104, United States
| | - Trevor L Vent
- Department of Radiology, University of Pennsylvania, Philadelphia, PA, 19104, United States
| | - Predrag R Bakic
- Department of Radiology, University of Pennsylvania, Philadelphia, PA, 19104, United States.,Department of Translational Medicine, Lund University, Malmö, 20502, Sweden
| | - Andrew D A Maidment
- Department of Radiology, University of Pennsylvania, Philadelphia, PA, 19104, United States
| |
Collapse
|
7
|
Zhu Y, O'Connell AM, Ma Y, Liu A, Li H, Zhang Y, Zhang X, Ye Z. Dedicated breast CT: state of the art-Part II. Clinical application and future outlook. Eur Radiol 2021; 32:2286-2300. [PMID: 34476564 DOI: 10.1007/s00330-021-08178-0] [Citation(s) in RCA: 16] [Impact Index Per Article: 5.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/30/2021] [Revised: 06/19/2021] [Accepted: 06/29/2021] [Indexed: 12/17/2022]
Abstract
Dedicated breast CT is being increasingly used for breast imaging. This technique provides images with no compression, removal of tissue overlap, rapid acquisition, and available simultaneous assessment of microcalcifications and contrast enhancement. In this second installment in a 2-part review, the current status of clinical applications and ongoing efforts to develop new imaging systems are discussed, with particular emphasis on how to achieve optimized practice including lesion detection and characterization, response to therapy monitoring, density assessment, intervention, and implant evaluation. The potential for future screening with breast CT is also addressed. KEY POINTS: • Dedicated breast CT is an emerging modality with enormous potential in the future of breast imaging by addressing numerous clinical needs from diagnosis to treatment. • Breast CT shows either noninferiority or superiority with mammography and numerical comparability to MRI after contrast administration in diagnostic statistics, demonstrates excellent performance in lesion characterization, density assessment, and intervention, and exhibits promise in implant evaluation, while potential application to breast cancer screening is still controversial. • New imaging modalities such as phase-contrast breast CT, spectral breast CT, and hybrid imaging are in the progress of R & D.
Collapse
Affiliation(s)
- Yueqiang Zhu
- Department of Radiology, Tianjin Medical University Cancer Institute and Hospital, National Clinical Research Center for Cancer, Key Laboratory of Cancer Prevention and Therapy, Tianjin, Tianjin's Clinical Research Center for Cancer, Key Laboratory of Breast Cancer Prevention and Therapy, Tianjin Medical University, Ministry of Education, Huan-Hu-Xi Road, Ti-Yuan-Bei, Hexi District, 300060, Tianjin, China
| | - Avice M O'Connell
- Department of Imaging Sciences, University of Rochester Medical Center, 601 Elmwood Avenue, Box 648, Rochester, NY, 14642, USA
| | - Yue Ma
- Department of Radiology, Tianjin Medical University Cancer Institute and Hospital, National Clinical Research Center for Cancer, Key Laboratory of Cancer Prevention and Therapy, Tianjin, Tianjin's Clinical Research Center for Cancer, Key Laboratory of Breast Cancer Prevention and Therapy, Tianjin Medical University, Ministry of Education, Huan-Hu-Xi Road, Ti-Yuan-Bei, Hexi District, 300060, Tianjin, China
| | - Aidi Liu
- Department of Radiology, Tianjin Medical University Cancer Institute and Hospital, National Clinical Research Center for Cancer, Key Laboratory of Cancer Prevention and Therapy, Tianjin, Tianjin's Clinical Research Center for Cancer, Key Laboratory of Breast Cancer Prevention and Therapy, Tianjin Medical University, Ministry of Education, Huan-Hu-Xi Road, Ti-Yuan-Bei, Hexi District, 300060, Tianjin, China
| | - Haijie Li
- Department of Radiology, Tianjin Medical University Cancer Institute and Hospital, National Clinical Research Center for Cancer, Key Laboratory of Cancer Prevention and Therapy, Tianjin, Tianjin's Clinical Research Center for Cancer, Key Laboratory of Breast Cancer Prevention and Therapy, Tianjin Medical University, Ministry of Education, Huan-Hu-Xi Road, Ti-Yuan-Bei, Hexi District, 300060, Tianjin, China
| | - Yuwei Zhang
- Department of Radiology, Tianjin Medical University Cancer Institute and Hospital, National Clinical Research Center for Cancer, Key Laboratory of Cancer Prevention and Therapy, Tianjin, Tianjin's Clinical Research Center for Cancer, Key Laboratory of Breast Cancer Prevention and Therapy, Tianjin Medical University, Ministry of Education, Huan-Hu-Xi Road, Ti-Yuan-Bei, Hexi District, 300060, Tianjin, China
| | - Xiaohua Zhang
- Koning Corporation, Lennox Tech Enterprise Center, 150 Lucius Gordon Drive, Suite 112, West Henrietta, NY, 14586, USA
| | - Zhaoxiang Ye
- Department of Radiology, Tianjin Medical University Cancer Institute and Hospital, National Clinical Research Center for Cancer, Key Laboratory of Cancer Prevention and Therapy, Tianjin, Tianjin's Clinical Research Center for Cancer, Key Laboratory of Breast Cancer Prevention and Therapy, Tianjin Medical University, Ministry of Education, Huan-Hu-Xi Road, Ti-Yuan-Bei, Hexi District, 300060, Tianjin, China.
| |
Collapse
|
8
|
Comparative analysis of the transmission properties of tissue equivalent materials. Radiat Phys Chem Oxf Engl 1993 2020. [DOI: 10.1016/j.radphyschem.2019.04.050] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/30/2022]
|
9
|
Caballo M, Michielsen K, Fedon C, Sechopoulos I. Towards 4D dedicated breast CT perfusion imaging of cancer: development and validation of computer simulated images. Phys Med Biol 2019; 64:245004. [PMID: 31703216 PMCID: PMC10424558 DOI: 10.1088/1361-6560/ab55ac] [Citation(s) in RCA: 6] [Impact Index Per Article: 1.2] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/12/2022]
Abstract
Dedicated breast CT is a fully tomographic breast imaging modality with potential for various applications throughout breast cancer care. If implemented to perform dynamic contrast-enhanced (CE) imaging (4D breast CT), it could be useful to obtain functional information at high combined spatio-temporal resolution. Before developing a 4D dedicated breast CT system, a computer simulation method for breast CT perfusion imaging is proposed. The simulation uses previously developed patient-based 4D digital breast phantoms, and generates realistic images with the selected acquisition parameters, allowing to investigate the effect of different acquisition settings on image quality. The simulation pipeline includes all steps of the image generation process, from ray tracing and scatter map generation, to the addition of realistic resolution losses and noise models. The pipeline was validated against experimental measurements performed on physical phantoms with a dedicated breast CT system, in terms of average error compared to ground truth projections (6.0% ± 1.65%), Hounsfield unit (HU) values in a homogeneous phantom (acquired: -149 HU ± 2 HU; simulated: -140 HU ± 2 HU), signal-to-noise ratio (SNR) (average error 6.7% ± 4.2%), noise power spectra (NPS) (average error 4.3% ± 2.5%), modulation transfer function (MTF) (average error 8.4% ± 7.2%), and attenuation of different adipose/glandular equivalent mixtures (average error 6.9% ± 4.0%) and glandular plus iodinated contrast medium concentrations equivalent mixtures (average error of 9.1% ± 9.0%). 4D patient images were then simulated for different 4D digital breast phantoms at different air kerma levels to determine the effect of noise on the extracted tumor perfusion curves. In conclusion, the proposed pipeline could simulate images with a good level of realism, resulting in a tool that can be used for the design, development, and optimization of a 4D dedicated breast CT system.
Collapse
Affiliation(s)
- Marco Caballo
- Department of Radiology and Nuclear Medicine, Radboud University Medical Center, PO Box 9101, 6500 HB Nijmegen, The Netherlands
| | - Koen Michielsen
- Department of Radiology and Nuclear Medicine, Radboud University Medical Center, PO Box 9101, 6500 HB Nijmegen, The Netherlands
| | - Christian Fedon
- Department of Radiology and Nuclear Medicine, Radboud University Medical Center, PO Box 9101, 6500 HB Nijmegen, The Netherlands
- Istituto Nazionale di Fisica Nucleare (INFN), sezione di Trieste, 34127 Trieste, Italy
| | - Ioannis Sechopoulos
- Department of Radiology and Nuclear Medicine, Radboud University Medical Center, PO Box 9101, 6500 HB Nijmegen, The Netherlands
- Dutch Expert Center for Screening (LRCB), PO Box 6873, 6503 GJ Nijmegen, The Netherlands
| |
Collapse
|
10
|
Caballo M, Fedon C, Brombal L, Mann R, Longo R, Sechopoulos I. Development of 3D patient-based super-resolution digital breast phantoms using machine learning. Phys Med Biol 2018; 63:225017. [PMID: 30418943 DOI: 10.1088/1361-6560/aae78d] [Citation(s) in RCA: 7] [Impact Index Per Article: 1.2] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/11/2022]
Abstract
Digital phantoms are important tools for optimization and evaluation of x-ray imaging systems, and should ideally reflect the 3D structure of human anatomy and its potential variability. In addition, they need to include a good level of detail at a high enough spatial resolution to accurately model the continuous nature of the human anatomy. A pipeline to increase the spatial resolution of patient-based digital breast phantoms that can be used for computer simulations of breast imaging is proposed. Given a tomographic breast image of finite resolution, the proposed methods can generate a phantom and increase its resolution at will, not only simply through super-sampling, but also by generating additional random glandular details to account for glandular edges and strands to compensate for those that may have not been detected in the original image due to the limited spatial resolution of the imaging system used. The proposed algorithms use supervised learning to predict the loss in glandularity due to limited resolution, and then to realistically recover this loss by learning the mapping between low and high resolution images. They were trained on high-resolution synchrotron images (detector pixel size 60 μm) reconstructed at seven voxel dimensions (60 μm-480 μm), and applied to patient images acquired with a clinical breast CT system (detector pixel size 194 μm) to generate super-resolution phantoms (voxel sizes 68 μm). Several evaluations were made to assess the appropriateness of the developed methods, both with the synchrotron (relative prediction error 0.010 ± 0.004, recovering accuracy 0.95 ± 0.04), and with the clinical images (average glandularity error at 194 μm: 0.15% ± 0.12%). Finally, a breast radiologist assessed the realism of the developed phantoms by blindly comparing original and phantom images, resulting in not being able to distinguish the real from the phantom images. In conclusion, the proposed method can generate super-resolution phantoms from tomographic breast patient images that can be used for future computer simulations for optimization of new breast imaging technologies.
Collapse
Affiliation(s)
- Marco Caballo
- Department of Radiology and Nuclear Medicine, Radboud University Medical Center, PO Box 9101, 6500 HB Nijmegen, Netherlands
| | | | | | | | | | | |
Collapse
|