Dube S, Pareek V, Barthwal M, Antony F, Sasaki D, Rivest R. Stereotactic Body Radiation Therapy (SBRT) in prostate cancer in the presence of hip prosthesis - is it a contraindication? A narrative review. BMC Urol 2024; 24:152. [PMID: 39061006 PMCID: PMC11282858 DOI: 10.1186/s12894-024-01479-8] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/05/2023] [Accepted: 04/06/2024] [Indexed: 07/28/2024] Open
Abstract
Hip replacement is a common orthopedic surgery in the aging population. With the rising incidence of prostate cancer, metallic hip prosthetics can cause considerable beam hardening and streak artifacts, leading to difficulty in identifying the target volumes and planning process for radiation treatment. The growing use of Stereotactic Body Radiation Therapy (SBRT) to treat prostate cancer is now well established. However, the use of this treatment modality in the presence of a hip prosthesis is poorly understood. There is enough literature on planning for external beam radiation treatment without any difficulties in the presence of hip prosthesis with conventional or Hypofractionated treatment. However, there is a shortage of literature on the impact of the prosthesis in SBRT planning, and there is a need for further understanding and measures to mitigate the obstacles in planning for SBRT in the presence of hip prosthesis. We present our review of the intricacies that need to be understood while considering SBRT in the presence of hip prostheses in prostate cancer treatment.
Collapse
Affiliation(s)
- Sheen Dube
- Department of Biochemistry, University of Winnipeg, Winnipeg, MB, Canada
| | - Vibhay Pareek
- Dept. of Radiation Oncology, CancerCare Manitoba, 675 McDermot Ave, Winnipeg, Winnipeg, MB, MB, R3E 0V9, Canada.
| | - Mansi Barthwal
- Dept. of Radiation Oncology, CancerCare Manitoba, 675 McDermot Ave, Winnipeg, Winnipeg, MB, MB, R3E 0V9, Canada
| | - Febin Antony
- Dept. of Radiation Oncology, CancerCare Manitoba, 675 McDermot Ave, Winnipeg, Winnipeg, MB, MB, R3E 0V9, Canada
| | - David Sasaki
- Department of Medical Physics, CancerCare Manitoba, Winnipeg, MB, Canada
| | - Ryan Rivest
- Department of Medical Physics, CancerCare Manitoba, Winnipeg, MB, Canada
| |
Collapse
|
2
|
Puvanasunthararajah S, Camps SM, Wille ML, Fontanarosa D. Deep learning-based ultrasound transducer induced CT metal artifact reduction using generative adversarial networks for ultrasound-guided cardiac radioablation. Phys Eng Sci Med 2023; 46:1399-1410. [PMID: 37548887 DOI: 10.1007/s13246-023-01307-7] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/20/2023] [Accepted: 07/20/2023] [Indexed: 08/08/2023]
Abstract
In US-guided cardiac radioablation, a possible workflow includes simultaneous US and planning CT acquisitions, which can result in US transducer-induced metal artifacts on the planning CT scans. To reduce the impact of these artifacts, a metal artifact reduction (MAR) algorithm has been developed based on a deep learning Generative Adversarial Network called Cycle-MAR, and compared with iMAR (Siemens), O-MAR (Philips) and MDT (ReVision Radiology), and CCS-MAR (Combined Clustered Scan-based MAR). Cycle-MAR was trained with a supervised learning scheme using sets of paired clinical CT scans with and without simulated artifacts. It was then evaluated on CT scans with real artifacts of an anthropomorphic phantom, and on sets of clinical CT scans with simulated artifacts which were not used for Cycle-MAR training. Image quality metrics and HU value-based analysis were used to evaluate the performance of Cycle-MAR compared to the other algorithms. The proposed Cycle-MAR network effectively reduces the negative impact of the metal artifacts. For example, the calculated HU value improvement percentage for the cardiac structures in the clinical CT scans was 59.58%, 62.22%, and 72.84% after MDT, CCS-MAR, and Cycle-MAR application, respectively. The application of MAR algorithms reduces the impact of US transducer-induced metal artifacts on CT scans. In comparison to iMAR, O-MAR, MDT, and CCS-MAR, the application of developed Cycle-MAR network on CT scans performs better in reducing these metal artifacts.
Collapse
Affiliation(s)
- Sathyathas Puvanasunthararajah
- School of Clinical Sciences, Queensland University of Technology, Brisbane, QLD, Australia.
- Centre for Biomedical Technologies, Queensland University of Technology, Brisbane, QLD, Australia.
| | | | - Marie-Luise Wille
- Centre for Biomedical Technologies, Queensland University of Technology, Brisbane, QLD, Australia
- School of Mechanical, Medical & Process Engineering, Faculty of Engineering, Queensland University of Technology, Brisbane, QLD, Australia
- ARC ITTC for Multiscale 3D Imaging, Modelling, and Manufacturing, Queensland University of Technology, Brisbane, QLD, Australia
| | - Davide Fontanarosa
- School of Clinical Sciences, Queensland University of Technology, Brisbane, QLD, Australia
- Centre for Biomedical Technologies, Queensland University of Technology, Brisbane, QLD, Australia
| |
Collapse
|
3
|
Puvanasunthararajah S, Camps SM, Wille ML, Fontanarosa D. Combined clustered scan-based metal artifact reduction algorithm (CCS-MAR) for ultrasound-guided cardiac radioablation. Phys Eng Sci Med 2022; 45:1273-1287. [PMID: 36352318 DOI: 10.1007/s13246-022-01192-6] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/02/2022] [Accepted: 10/20/2022] [Indexed: 11/11/2022]
Abstract
Cardiac radioablation is a promising treatment for cardiac arrhythmias, but accurate dose delivery can be affected by heart motion. For this reason, real-time cardiac motion monitoring during radioablation is of paramount importance. Real-time ultrasound (US) guidance can be a solution. The US-guided cardiac radioablation workflow can be simplified by the simultaneous US and planning computed tomography (CT) acquisition, which can result in US transducer-induced metal artifacts on the planning CT scans. To reduce the impact of these artifacts, a new metal artifact reduction (MAR) algorithm (named: Combined Clustered Scan-based MAR [CCS-MAR]) has been developed and compared with iMAR (Siemens), O-MAR (Philips) and MDT (ReVision Radiology) algorithms. CCS-MAR is a fully automated sinogram inpainting-based MAR algorithm, which uses a two-stage correction process based on a normalized MAR method. The second stage aims to correct errors remaining from the first stage to create an artifact-free combined clustered scan for the process of metal artifact reduction. To evaluate the robustness of CCS-MAR, conventional CT scans and/or dual-energy CT scans from three anthropomorphic phantoms and transducers with different sizes were used. The performance of CCS-MAR for metal artifact reduction was compared with other algorithms through visual comparison, image quality metrics analysis, and HU value restoration evaluation. The results of this study show that CCS-MAR effectively reduced the US transducer-induced metal artifacts and that it improved HU value accuracy more or comparably to other MAR algorithms. These promising results justify future research into US transducer-induced metal artifact reduction for the US-guided cardiac radioablation purposes.
Collapse
Affiliation(s)
- Sathyathas Puvanasunthararajah
- School of Clinical Sciences, Queensland University of Technology, Brisbane, QLD, Australia. .,Centre for Biomedical Technologies, Queensland University of Technology, Brisbane, QLD, Australia.
| | | | - Marie-Luise Wille
- Centre for Biomedical Technologies, Queensland University of Technology, Brisbane, QLD, Australia.,School of Mechanical, Medical & Process Engineering, Faculty of Engineering, Queensland University of Technology, Brisbane, QLD, Australia.,ARC ITTC for Multiscale 3D Imaging, Modelling, and Manufacturing, Queensland University of Technology, Brisbane, QLD, Australia
| | - Davide Fontanarosa
- School of Clinical Sciences, Queensland University of Technology, Brisbane, QLD, Australia.,Centre for Biomedical Technologies, Queensland University of Technology, Brisbane, QLD, Australia
| |
Collapse
|
4
|
Sarigul N. Evaluation of the effect of field sizes on radiation dose in the presence of metal materials using Monte Carlo simulation. Appl Radiat Isot 2022; 182:110143. [DOI: 10.1016/j.apradiso.2022.110143] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/16/2021] [Revised: 01/21/2022] [Accepted: 02/07/2022] [Indexed: 11/02/2022]
|
5
|
Jurado-Bruggeman D, Muñoz-Montplet C, Hernandez V, Saez J, Fuentes-Raspall R. Impact of the dose quantity used in MV photon optimization on dose distribution, robustness, and complexity. Med Phys 2021; 49:648-665. [PMID: 34855988 DOI: 10.1002/mp.15389] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/29/2021] [Revised: 10/09/2021] [Accepted: 11/18/2021] [Indexed: 11/09/2022] Open
Abstract
PURPOSE Convolution/superposition algorithms used in megavoltage (MV) photon radiotherapy model radiation transport in water, yielding dose to water-in-water (Dw,w ). Advanced algorithms constitute a step forward, but their dose distributions in terms of dose to medium-in-medium (Dm,m ) or dose to water-in-medium (Dw,m ) can be problematic when used in plan optimization due to their different dose responses to some atomic composition heterogeneities. Failure to take this into account can lead to undesired overcorrections and thus to unnoticed suboptimal and unrobust plans. Dose to reference-like medium (Dref,m* ) was recently introduced to overcome these limitations while ensuring accurate transport. This work evaluates and compares the performance of these four dose quantities in planning target volume (PTV)-based optimization. METHODS We considered three cases with heterogeneities inside the PTV: virtual phantom with water surrounded by bone; head and neck; and lung. These cases were planned with volumetric modulated arc therapy (VMAT) technique, optimizing with the same setup and objectives for each dose quantity. We used different algorithms of the Varian Eclipse treatment planning system (TPS): Acuros XB (AXB) for Dm,m and Dw,m , and Analytical Anisotropic Algorithm (AAA) for Dw,w . Dref,m* was obtained from Dm,m distributions using an in-house software considering water as the reference medium (Dw,m* ). The optimization process consisted of: (1) common first optimization, (2) dose distribution computed for each quantity, (3) re-optimization, and (4) final calculation for each dose quantity. The dose distribution, robustness to patient setup errors, and complexity of the plans were analyzed and compared. RESULTS The quantities showed similar dose distributions after the optimization but differed in terms of plan robustness. The cases with soft tissue and high-density heterogeneities followed the same pattern. For AXB Dm,m , cold regions appeared in the heterogeneities after the first optimization. They were compensated in the second optimization through local fluence increases, but any positional mismatch impacted robustness, with clinical target volume (CTV) variations from the nominal scenario around +3% for bone and up to +7% for metal. For AXB Dw,m the pattern was inverse (hot regions compensated by fluence decreases) and more pronounced, with CTV dose variations around -7% for bone and up to -17% for metal. Neither AXB Dw,m* nor AAA Dw,w presented these dose inhomogeneities, which resulted in more robust plans. However, Dw,w differed markedly from the other quantities in the lung case because of its lower radiation transport accuracy. AXB Dm,m was the most complex of the four dose quantities and AXB Dw,m* the least complex, though we observed no major differences in this regard. CONCLUSIONS The dose quantity used in MV photon optimization can affect plan robustness. Dw,w distributions from convolution/superposition algorithms are robust but may not provide sufficient radiation transport accuracy in some cases. Dm,m and Dw,m from advanced algorithms can compromise robustness because their different responses to some composition heterogeneities introduce additional fluence compensations. Dref,m* offers advantages in plan optimization and evaluation, producing accurate and robust plans without increasing complexity. Dref,m* can be easily implemented as a built-in feature of the TPS and can facilitate and simplify the treatment planning process when using advanced algorithms. Final reporting can be kept in Dm,m or Dw,m for clinical correlations.
Collapse
Affiliation(s)
- Diego Jurado-Bruggeman
- Medical Physics and Radiation Protection Department, Institut Català d'Oncologia, Girona, Spain
| | - Carles Muñoz-Montplet
- Medical Physics and Radiation Protection Department, Institut Català d'Oncologia, Girona, Spain.,Department of Medical Sciences, University of Girona, Girona, Spain
| | - Victor Hernandez
- Department of Medical Physics, Hospital Universitari Sant Joan de Reus, IISPV, Tarragona, Spain.,Universitat Rovira i Virgili, Tarragona, Spain
| | - Jordi Saez
- Department of Radiation Oncology, Hospital Clínic de Barcelona, Barcelona, Spain
| | - Rafael Fuentes-Raspall
- Department of Medical Sciences, University of Girona, Girona, Spain.,Radiation Oncology Department, Institut Català d'Oncologia, Girona, Spain
| |
Collapse
|
6
|
Koutsouvelis N, Dipasquale G, Rouzaud M, Dubouloz A, Nouet P, Jaccard M, Miralbell R, Tsoutsou P, Zilli T. Bilateral metallic hip implants: Are avoidance sectors necessary for pelvic VMAT treatments? Z Med Phys 2021; 31:420-427. [PMID: 34210536 DOI: 10.1016/j.zemedi.2021.05.002] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/20/2020] [Revised: 03/29/2021] [Accepted: 05/26/2021] [Indexed: 11/29/2022]
Abstract
PURPOSE Metallic hip implants (MHI) are common in elderly patients. For pelvic cancers radiotherapy, conventional approaches consist of MHI avoidance during treatment planning, which leads, especially in case of bilateral MHI, to a decreased quality or increased complexity of the treatment plan. The aim of this study is to investigate the necessity of using avoidance sectors (AvSe) using a 2-arcs coplanar pelvic volumetric modulated arc-therapy (VMAT) planning. METHODS We evaluated: (1) The dose calculation error of a static 6MV open beam traversing a MHI; (2) The magnitude of an error's decrease within the planning target volume (PTV) for a 360° VMAT treatment without AvSe as compared to the static open beam; (3) The dosimetric influence of MHI misalignment generated by patient's repositioning rolls during image-guided radiotherapy (IGRT). RESULTS (1) In the static 6MV beam configuration, for distances between 0.5cm and 6cm from the MHI, the median (maximum, number of points) dose calculation error was -1.55% (-2.5%, 11); (2) Compared to the static open beam, in the 360° VMAT treatment without AvSe a simulated error was decreased by a factor of 4.4/2.4 (median/minimum); (3) MHI anterior-posterior misalignment exceeding 0.6cm, resulted in error at PTV surface of >2%. CONCLUSIONS A standard 2 coplanar arcs 360° VMAT treatment, with dedicated artifact reduction algorithms applied, decreased the error of static beam traversing MHI, in patients presenting a bilateral MHI and might be used to treat the pelvic region without MHI avoidance.
Collapse
Affiliation(s)
| | - Giovanna Dipasquale
- Department of Radiation Oncology, Geneva University Hospital, Geneva, Switzerland
| | - Michel Rouzaud
- Department of Radiation Oncology, Geneva University Hospital, Geneva, Switzerland
| | - Angele Dubouloz
- Department of Radiation Oncology, Geneva University Hospital, Geneva, Switzerland
| | - Philippe Nouet
- Department of Radiation Oncology, Geneva University Hospital, Geneva, Switzerland
| | - Maud Jaccard
- Department of Radiation Oncology, Geneva University Hospital, Geneva, Switzerland
| | - Raymond Miralbell
- Department of Radiation Oncology, Geneva University Hospital, Geneva, Switzerland; Faculty of Medicine, Geneva University, Geneva, Switzerland
| | - Pelagia Tsoutsou
- Department of Radiation Oncology, Geneva University Hospital, Geneva, Switzerland; Faculty of Medicine, Geneva University, Geneva, Switzerland
| | - Thomas Zilli
- Department of Radiation Oncology, Geneva University Hospital, Geneva, Switzerland; Faculty of Medicine, Geneva University, Geneva, Switzerland
| |
Collapse
|
7
|
Puvanasunthararajah S, Fontanarosa D, Wille M, Camps SM. The application of metal artifact reduction methods on computed tomography scans for radiotherapy applications: A literature review. J Appl Clin Med Phys 2021; 22:198-223. [PMID: 33938608 PMCID: PMC8200502 DOI: 10.1002/acm2.13255] [Citation(s) in RCA: 12] [Impact Index Per Article: 3.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/28/2021] [Revised: 03/21/2021] [Accepted: 03/30/2021] [Indexed: 12/22/2022] Open
Abstract
Metal artifact reduction (MAR) methods are used to reduce artifacts from metals or metal components in computed tomography (CT). In radiotherapy (RT), CT is the most used imaging modality for planning, whose quality is often affected by metal artifacts. The aim of this study is to systematically review the impact of MAR methods on CT Hounsfield Unit values, contouring of regions of interest, and dose calculation for RT applications. This systematic review is performed in accordance with the PRISMA guidelines; the PubMed and Web of Science databases were searched using the main keywords "metal artifact reduction", "computed tomography" and "radiotherapy". A total of 382 publications were identified, of which 40 (including one review article) met the inclusion criteria and were included in this review. The selected publications (except for the review article) were grouped into two main categories: commercial MAR methods and research-based MAR methods. Conclusion: The application of MAR methods on CT scans can improve treatment planning quality in RT. However, none of the investigated or proposed MAR methods was completely satisfactory for RT applications because of limitations such as the introduction of other errors (e.g., other artifacts) or image quality degradation (e.g., blurring), and further research is still necessary to overcome these challenges.
Collapse
Affiliation(s)
- Sathyathas Puvanasunthararajah
- School of Clinical SciencesQueensland University of TechnologyBrisbaneQLDAustralia
- Centre for Biomedical TechnologiesQueensland University of TechnologyBrisbaneQLDAustralia
| | - Davide Fontanarosa
- School of Clinical SciencesQueensland University of TechnologyBrisbaneQLDAustralia
- Centre for Biomedical TechnologiesQueensland University of TechnologyBrisbaneQLDAustralia
| | - Marie‐Luise Wille
- Centre for Biomedical TechnologiesQueensland University of TechnologyBrisbaneQLDAustralia
- School of MechanicalMedical & Process EngineeringFaculty of EngineeringQueensland University of TechnologyBrisbaneQLDAustralia
- ARC ITTC for Multiscale 3D Imaging, Modelling, and ManufacturingQueensland University of TechnologyBrisbaneQLDAustralia
| | | |
Collapse
|