Choi CH, Felder J, Lerche C, Shah NJ. MRI Coil Development Strategies for Hybrid MR-PET Systems: A Review. IEEE Rev Biomed Eng 2024; 17:342-350. [PMID: 37015609 DOI: 10.1109/rbme.2022.3227337] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/12/2022]
Abstract
Simultaneously operating MR-PET systems have the potential to provide synergetic multi-parametric information, and, as such, interest surrounding their use and development is increasing. However, despite the potential advantages offered by fully combined MR-PET systems, implementing this hybrid integration is technically laborious, and any factors degrading the quality of either modality must be circumvented to ensure optimal performance. In order to attain the best possible quality from both systems, most full MR-PET integrations tend to place the shielded PET system inside the MRI system, close to the target volume of the subject. The radiofrequency (RF) coil used in MRI systems is a key factor in determining the quality of the MR images, and, in simultaneous acquisition, it is generally positioned inside the PET system and PET imaging region, potentially resulting in attenuation and artefacts in the PET images. Therefore, when designing hybrid MR-PET systems, it is imperative that consideration be given to the RF coils inside the PET system. In this review, we present current state-of-the-art RF coil designs used for hybrid MR-PET experiments and discuss various design strategies for constructing PET transparent RF coils.
Collapse
|
2
|
Choi CH, Hong SM, Felder J, Tellmann L, Scheins J, Kops ER, Lerche C, Shah NJ. A Novel J-Shape Antenna Array for Simultaneous MR-PET or MR-SPECT Imaging. IEEE TRANSACTIONS ON MEDICAL IMAGING 2022; 41:1104-1113. [PMID: 34860648 DOI: 10.1109/tmi.2021.3132576] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 06/13/2023]
Abstract
Simultaneous MR-PET/-SPECT is an emerging technology that capitalises on the invaluable advantages of both modalities, allowing access to numerous sensitive tracers and superior soft-tissue contrast alongside versatile functional imaging capabilities. However, to optimise these capabilities, concurrent acquisitions require the MRI antenna located inside the PET/SPECT field-of-view to be operated without compromising any aspects of system performance or image quality compared to the stand-alone instrumentation. Here, we report a novel gamma-radiation-transparent antenna concept. The end-fed J-shape antenna is particularly adept for hybrid ultra-high field MR-PET/-SPECT applications as it enables all highly attenuating materials to be placed outside the imaging field-of-view. Furthermore, this unique configuration also provides advantages in stand-alone MR applications by reducing the amount of coupling between the cables and the antenna elements, and by lowering the potential specific absorption rate burden. The use of this new design was experimentally verified according to the important features for both ultra-high field MRI and the 511 keV transmission scan. The reconstructed attenuation maps evidently showed much lower attenuation ( ∼ 15 %) for the proposed array when compared to the conventional dipole antenna array since there were no high-density components. In MR, it was observed that the signal-to-noise ratio from the whole volume obtained using the proposed array was comparable to that acquired by the conventional array which was also in agreement with the simulation results. The unique feature, J-shape array, would enable simultaneous MR-PET/-SPECT experiments to be conducted without unduly compromising any aspects of system performance and image quality compared to the stand-alone instrumentation.
Collapse
|
3
|
Rao F, Wu Z, Han L, Yang B, Han W, Zhu W. Delayed PET imaging using image synthesis network and nonrigid registration without additional CT scan. Med Phys 2022; 49:3233-3245. [PMID: 35218053 DOI: 10.1002/mp.15574] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/07/2021] [Revised: 02/02/2022] [Accepted: 02/15/2022] [Indexed: 11/10/2022] Open
Abstract
PURPOSE Attenuation correction is critical for positron emission tomography (PET) image reconstruction. The standard protocol for obtaining attenuation information in a clinical PET scanner is via the coregistered computed tomography (CT) images. Therefore for delayed PET imaging, the CT scan is repeated twice, which increases the radiation dose for the patient. In this paper, we propose a zero-extra-dose delayed PET imaging method which requires no additional CT scans. METHODS A deep learning based synthesis network is designed to convert the PET data into a pseudo CT image for the delayed scan. Then, nonrigid registration is performed between this pseudo CT image and the CT image of the first scan, warping the CT image of the first scan to an estimated CT images for the delayed scan. Finally, the PET image attenuation correction in the delayed scan is obtained from this estimated CT image. Experiments with clinical datasets are implemented to assess the effectiveness of the proposed method with the well-recognized GAN method. The average peak signal-to-noise ratio (PSNR) and the mean absolute percent error (MAPE) are used in comparison. We also use scoring from three experienced radiologists as subjective measurement means, based on the diagnostic consistency of the PET images reconstructed from GAN and the proposed method with respect to the ground truth images. RESULTS The experiments show that the average PSNR is 47.04 dB (the proposed method) v.s. 44.41 dB (the traditional GAN method) for the reconstructed delayed PET images in our evaluation dataset. The average MAPEs are 1.59% for the proposed method and 3.32% for the traditional GAN method across five organ Regions of Interest (ROIs). The scores for the GAN and the proposed method rated by three experienced radiologists are 8.08±0.60 and 9.02±0.52, indicating that the proposed method yields more consistent PET images with the ground truth. CONCLUSIONS This work proposes a novel method for CT-less delayed PET imaging based on image synthesis network and nonrigid image registration. The PET image reconstructed using the proposed method yields delayed PET images with high image quality without artifacts, and is quantitatively more accurate compared with the traditional GAN method. This article is protected by copyright. All rights reserved.
Collapse
Affiliation(s)
- Fan Rao
- Research Center for Healthcare Data Science, Zhejiang Lab, China
| | - Zhuoxuan Wu
- Department of Medical Oncology, Sir Run Run Shaw Hospital, College of Medicine, Zhejiang University, China
| | - Lu Han
- Research Center for Healthcare Data Science, Zhejiang Lab, China
| | - Bao Yang
- Research Center for Healthcare Data Science, Zhejiang Lab, China
| | - Weidong Han
- Department of Medical Oncology, Sir Run Run Shaw Hospital, College of Medicine, Zhejiang University, China
| | - Wentao Zhu
- Research Center for Healthcare Data Science, Zhejiang Lab, China
| |
Collapse
|
4
|
Lindemann ME, Oehmigen M, Lanz T, Grafe H, Bruckmann NM, Umutlu L, Quick HH. Evaluation of improved CT‐based hardware attenuation correction in PET/MRI: Application to a 16‐channel RF breast coil. Med Phys 2022; 49:2279-2294. [DOI: 10.1002/mp.15535] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/08/2021] [Revised: 01/19/2022] [Accepted: 02/05/2022] [Indexed: 11/10/2022] Open
Affiliation(s)
- Maike E. Lindemann
- High‐Field and Hybrid MR Imaging University Hospital Essen University Duisburg‐Essen Essen Germany
| | - Mark Oehmigen
- High‐Field and Hybrid MR Imaging University Hospital Essen University Duisburg‐Essen Essen Germany
| | | | - Hong Grafe
- Department of Nuclear Medicine University Hospital Essen University Duisburg‐Essen Essen Germany
| | - Nils Martin Bruckmann
- Department of Diagnostic and Interventional Radiology University Hospital Duesseldorf University Duesseldorf Duesseldorf Germany
| | - Lale Umutlu
- Department of Diagnostic and Interventional Radiology and Neuroradiology University Hospital Essen University of Duisburg‐Essen Essen Germany
| | - Harald H. Quick
- High‐Field and Hybrid MR Imaging University Hospital Essen University Duisburg‐Essen Essen Germany
- Erwin L. Hahn Institute for Magnetic Resonance Imaging University Duisburg‐Essen Essen Germany
| |
Collapse
|
5
|
Lindemann ME, Oehmigen M, Lanz T, Grafe H, Bruckmann NM, Umutlu L, Quick HH. CAD-based hardware attenuation correction in PET/MRI: First methodical investigations and clinical application of a 16-channel RF breast coil. Med Phys 2021; 48:6696-6709. [PMID: 34655079 DOI: 10.1002/mp.15284] [Citation(s) in RCA: 4] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/09/2021] [Revised: 10/01/2021] [Accepted: 10/02/2021] [Indexed: 12/11/2022] Open
Abstract
PURPOSE Aim of this study was to evaluate the use of computer-aided design (CAD) models for attenuation correction (AC) of hardware components in positron emission tomography/magnetic resonance (PET/MR) imaging. METHODS The technical feasibility and quantitative impact of CAD-AC compared to computer tomography (CT)-based AC (reference) was investigated on a modular phantom consisting of 19 different material samples (plastics and metals arranged around a cylindrical emission phantom) typically used in phantoms, patient tables, and radiofrequency (RF) coils in PET/MR. The clinical applicability of the CAD-AC method was then evaluated on a 16-channel RF breast coil in a PET/MR patient study. The RF breast coil in this study was specifically designed PET compatible. Using this RF breast coil, the impact on clinical PET/MR breast imaging was systematically evaluated in breast phantom measurements and, furthermore, in n = 10 PET/MR patients with breast cancer. PET data were reconstructed three times: (1) no AC (NAC), (2) established CT-AC, and (3) CAD-AC. For both phantom measurements, a scan without attenuating hardware components (material probes or RF breast coil) was acquired serving as reference. Relative differences in PET data were calculated for all experiments. RESULTS In all phantom and patient measurements, significant gains in PET signal compared to NAC data were measurable with CT and CAD-AC. In initial phantom experiments, mean relative differences of -0.2% for CT-AC and 0.2% for CAD-AC were calculated compared to reference measurements without the material probes. The application to a RF breast coil depicts that CAD-AC results in significant gains compared to NAC data (10%) and a slight underestimation in PET signal of -1.3% in comparison to the no-coil reference measurement. In the patient study, a total of 15 congruent lesions in all 10 patients with a mean relative difference of 14% (CT and CAD-AC) in standardized uptake value compared to NAC data could be detected. CONCLUSIONS To ensure best possible PET image quality and accurate PET quantification in PET/MR imaging, the AC of hardware components such as phantoms and RF coils is important. In initial phantom experiments and in clinical application to an RF breast coil, it was found that CAD-based AC results in significant gains in PET signal compared to NAC data and provides comparably good results to the established method of CT-based AC.
Collapse
Affiliation(s)
- Maike E Lindemann
- High-Field and Hybrid MR Imaging, University Hospital Essen, University of Duisburg-Essen, Essen, Germany
| | - Mark Oehmigen
- High-Field and Hybrid MR Imaging, University Hospital Essen, University of Duisburg-Essen, Essen, Germany
| | | | - Hong Grafe
- Department of Nuclear Medicine, University Hospital Essen, University of Duisburg-Essen, Essen, Germany
| | - Nils Martin Bruckmann
- Department of Diagnostic and Interventional Radiology, University Hospital Duesseldorf, University of Duesseldorf, Duesseldorf, Germany
| | - Lale Umutlu
- Department of Diagnostic and Interventional Radiology and Neuroradiology, University Hospital Essen, University of Duisburg-Essen, Essen, Germany
| | - Harald H Quick
- High-Field and Hybrid MR Imaging, University Hospital Essen, University of Duisburg-Essen, Essen, Germany.,Erwin L. Hahn Institute for Magnetic Resonance Imaging, University of Duisburg-Essen, Essen, Germany
| |
Collapse
|
6
|
Improved PET/MRI accuracy by use of static transmission source in empirically derived hardware attenuation correction. EJNMMI Phys 2021; 8:24. [PMID: 33683464 PMCID: PMC7940463 DOI: 10.1186/s40658-021-00368-5] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/15/2020] [Accepted: 02/22/2021] [Indexed: 12/18/2022] Open
Abstract
Background Accurate quantification of radioactivity, measured by an integrated positron emission tomography (PET) and magnetic resonance imaging (MRI) system, is still a challenge. One aspect of such a challenge is to correct for the hardware attenuation, such as the patient table and radio frequency (RF) resonators. For PET/MRI systems, computed tomography (CT) is commonly used to produce hardware attenuation correction (AC) maps, by converting Hounsfield units (HU) to a linear attenuation coefficients (LAC) map at the PET energy level 511 keV, using a bilinear model. The model does not address beam hardening, nor higher density materials, which can lead to inaccurate corrections. Purpose In this study, we introduce a transmission-based (TX-based) AC technique with a static Germanium-68 (Ge-68) transmission source to generate hardware AC maps using the PET/MRI system itself, without the need for PET or medical CT scanners. The AC TX-based maps were generated for a homogeneous cylinder, made of acrylic as a validator. The technique thereafter was applied to the patient table and posterior part of an RF-phased array used in cardiovascular PET/MRI imaging. The proposed TX-based, and the CT-based, hardware maps were used in reconstructing PET images of one cardiac patient, and the results were analysed and compared. Results The LAC derived by the TX-based method for the acrylic cylinder is estimated to be 0.10851 ± 0.00380 cm−1 compared to the 0.10698 ± 0.00321 cm−1 theoretical value reported in the literature. The PET photon counts were reduced by 8.7 ± 1.1% with the patient table, at the region used in cardiac scans, while the CT-based map, used for correction, over-estimated counts by 4.3 ± 1.3%. Reconstructed in vivo images using TX-based AC hardware maps have shown 4.1 ± 0.9% mean difference compared to those reconstructed images using CT-based AC. Conclusions The LAC of the acrylic cylinder measurements using the TX-based technique was in agreement with those in the literature confirming the validity of the technique. The over-estimation of photon counts caused by the CT-based model used for the patient table was improved by the TX-based technique. Therefore, TX-based AC of hardware using the PET/MRI system itself is possible and can produce more accurate images when compared to the CT-based hardware AC in cardiac PET images.
Collapse
|
7
|
Rao F, Yang B, Chen YW, Li J, Wang H, Ye H, Wang Y, Zhao K, Zhu W. A novel supervised learning method to generate CT images for attenuation correction in delayed pet scans. COMPUTER METHODS AND PROGRAMS IN BIOMEDICINE 2020; 197:105764. [PMID: 33010702 DOI: 10.1016/j.cmpb.2020.105764] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.6] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 05/19/2020] [Accepted: 09/14/2020] [Indexed: 06/11/2023]
Abstract
BACKGROUND AND OBJECTIVES Attenuation correction is important for PET image reconstruction. In clinical PET/CT scans, the attenuation information is usually obtained by CT. However, additional CT scans for delayed PET imaging may increase the risk of cancer. In this paper, we propose a novel CT generation method for attenuation correction in delayed PET imaging that requires no additional CT scans. METHODS As only PET raw data is available for the delayed PET scan, routine image registration methods are difficult to use directly. To solve this problem, a reconstruction network is developed to produce pseudo PET images from raw data first. Then a second network is used to generate the CT image through mapping PET/CT images from the first scan to the delayed scan. The inputs of the second network are the two pseudo PET images from the first and delayed scans, and the CT image from the first scan. The labels are taken from the ground truth CT image in the delayed scan. The loss function contains an image similarity term and a regularization term, which reflect the anatomy matching accuracy and the smoothness of the non-rigid deformation field, respectively. RESULTS We evaluated the proposed method with simulated and clinical PET/CT datasets. Standard Uptake Value was computed and compared with the gold standard (with coregistered CT for attenuation correction). The results show that the proposed supervised learning method can generate PET images with high quality and quantitative accuracy. For the test cases in our study, the average MAE and RMSE of the proposed supervised learning method were 4.61 and 22.75 respectively, and the average PSNR between the reconstructed PET image and the ground truth PET image was 62.13 dB. CONCLUSIONS The proposed method is able to generate accurate CT images for attenuation correction in delayed PET scans. Experiments indicate that the proposed method outperforms traditional methods with respect to quantitative PET image accuracy.
Collapse
Affiliation(s)
- Fan Rao
- Research Center for Healthcare Data Science, Zhejiang Lab, Hangzhou, China
| | - Bao Yang
- Research Center for Healthcare Data Science, Zhejiang Lab, Hangzhou, China
| | - Yen-Wei Chen
- Research Center for Healthcare Data Science, Zhejiang Lab, Hangzhou, China
| | - Jingsong Li
- Research Center for Healthcare Data Science, Zhejiang Lab, Hangzhou, China
| | - Hongkai Wang
- School of Biomedical Engineering, Dalian University of Technology, Dalian, China
| | - Hongwei Ye
- MinFound Medical Systems Co., Ltd. Hangzhou, China
| | - Yaofa Wang
- MinFound Medical Systems Co., Ltd. Hangzhou, China
| | - Kui Zhao
- PET Center, The First Affiliated Hospital, College of Medicine, Zhejiang University, Zhejiang, China
| | - Wentao Zhu
- Research Center for Healthcare Data Science, Zhejiang Lab, Hangzhou, China.
| |
Collapse
|