Metal Artifact Reduction in Photon-Counting Detector CT: Quantitative Evaluation of Artifact Reduction Techniques. Invest Radiol 2024; 59:442-449. [PMID: 37812482 DOI: 10.1097/rli.0000000000001036] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/10/2023]
Abstract
OBJECTIVES With the introduction of clinical photon-counting detector computed tomography (PCD-CT) and its novel reconstruction techniques, a quantitative investigation of different acquisition and reconstruction settings is necessary to optimize clinical acquisition protocols for metal artifact reduction. MATERIALS AND METHODS A multienergy phantom was scanned on a clinical dual-source PCD-CT (NAEOTOM Alpha; Siemens Healthcare GmbH) with 4 different central inserts: water-equivalent plastic, aluminum, steel, and titanium. Acquisitions were performed at 120 kVp and 140 kVp (CTDI vol 10 mGy) and reconstructed as virtual monoenergetic images (VMIs; 110-150 keV), as T3D, and with the standard reconstruction "none" (70 keV VMI) using different reconstruction kernels (Br36, Br56) and with as well as without iterative metal artifact reduction (iMAR). Metal artifacts were quantified, calculating relative percentages of metal artifacts. Mean CT numbers of an adjacent water-equivalent insert and different tissue-equivalent inserts were evaluated, and eccentricity of metal rods was measured. Repeated-measures analysis of variance was performed for statistical analysis. RESULTS Metal artifacts were most prevalent for the steel insert (12.6% average artifacts), followed by titanium (4.2%) and aluminum (1.0%). The strongest metal artifact reduction was noted for iMAR (with iMAR: 1.4%, without iMAR: 10.5%; P < 0.001) or VMI (VMI: 110 keV 2.6% to 150 keV 3.3%, T3D: 11.0%, and none: 16.0%; P < 0.001) individually, with best results when combining iMAR and VMI at 110 keV (1.2%). Changing acquisition tube potential (120 kV: 6.6%, 140 kV: 5.2%; P = 0.33) or reconstruction kernel (Br36: 5.5%, Br56: 6.4%; P = 0.17) was less effective. Mean CT numbers and standard deviations were significantly affected by iMAR (with iMAR: -3.0 ± 21.5 HU, without iMAR: -8.5 ± 24.3 HU; P < 0.001), VMI (VMI: 110 keV -3.6 ± 21.6 HU to 150 keV -1.4 ± 21.2 HU, T3D: -11.7 ± 23.8 HU, and none: -16.9 ± 29.8 HU; P < 0.001), tube potential (120 kV: -4.7 ± 22.8 HU, 140 kV: -6.8 ± 23.0 HU; P = 0.03), and reconstruction kernel (Br36: -5.5 ± 14.2 HU, Br56: -6.8 ± 23.0 HU; P < 0.001). Both iMAR and VMI improved quantitative CT number accuracy and metal rod eccentricity for the steel rod, but iMAR was of limited effectiveness for the aluminum rod. CONCLUSIONS For metal artifact reduction in PCD-CT, a combination of iMAR and VMI at 110 keV demonstrated the strongest artifact reduction of the evaluated options, whereas the impact of reconstruction kernel and tube potential was limited.
Collapse
|
2
|
Photon-counting detector CT - first experiences in the field of musculoskeletal radiology. ROFO-FORTSCHR RONTG 2024. [PMID: 38788741 DOI: 10.1055/a-2312-6914] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 05/26/2024]
Abstract
The introduction of photon-counting detector CT (PCD-CT) marks a remarkable leap in innovation in CT imaging. The new detector technology allows X-rays to be converted directly into an electrical signal without an intermediate step via a scintillation layer and allows the energy of individual photons to be measured. Initial data show high spatial resolution, complete elimination of electronic noise, and steady availability of spectral image data sets. In particular, the new technology shows promise with respect to the imaging of osseous structures. Recently, PCD-CT was implemented in the clinical routine. The aim of this review was to summarize recent studies and to show our first experiences with photon-counting detector technology in the field of musculoskeletal radiology.We performed a literature search using Medline and included a total of 90 articles and reviews that covered recent experimental and clinical experiences with the new technology.In this review, we focus on (1) spatial resolution and delineation of fine anatomic structures, (2) reduction of radiation dose, (3) electronic noise, (4) techniques for metal artifact reduction, and (5) possibilities of spectral imaging. This article provides insight into our first experiences with photon-counting detector technology and shows results and images from experimental and clinical studies. · This review summarizes recent experimental and clinical studies in the field of photon-counting detector CT and musculoskeletal radiology.. · The potential of photon-counting detector technology in the field of musculoskeletal radiology includes improved spatial resolution, reduction in radiation dose, metal artifact reduction, and spectral imaging.. · PCD-CT enables imaging at lower radiation doses while maintaining or even enhancing spatial resolution, crucial for reducing patient exposure, especially in repeated or prolonged imaging scenarios.. · It offers promising results in reducing metal artifacts commonly encountered in orthopedic or dental implants, enhancing the interpretability of adjacent structures in postoperative and follow-up imaging.. · With its ability to routinely acquire spectral data, PCD-CT scans allow for material classification, such as detecting urate crystals in suspected gout or visualizing bone marrow edema, potentially reducing reliance on MRI in certain cases.. Bette S, Risch F, Becker J et al. Photon-counting detector CT - first experiences in the field of musculoskeletal radiology. Fortschr Röntgenstr 2024; DOI 10.1055/a-2312-6914.
Collapse
|
3
|
Influence of helical pitch and gantry rotation time on image quality and file size in ultrahigh-resolution photon-counting detector CT. Sci Rep 2024; 14:9358. [PMID: 38653758 DOI: 10.1038/s41598-024-59729-6] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/02/2023] [Accepted: 04/15/2024] [Indexed: 04/25/2024] Open
Abstract
The goal of this experimental study was to quantify the influence of helical pitch and gantry rotation time on image quality and file size in ultrahigh-resolution photon-counting CT (UHR-PCCT). Cervical and lumbar spine, pelvis, and upper legs of two fresh-frozen cadaveric specimens were subjected to nine dose-matched UHR-PCCT scan protocols employing a collimation of 120 × 0.2 mm with varying pitch (0.3/1.0/1.2) and rotation time (0.25/0.5/1.0 s). Image quality was analyzed independently by five radiologists and further substantiated by placing normed regions of interest to record mean signal attenuation and noise. Effective mAs, CT dose index (CTDIvol), size-specific dose estimate (SSDE), scan duration, and raw data file size were compared. Regardless of anatomical region, no significant difference was ascertained for CTDIvol (p ≥ 0.204) and SSDE (p ≥ 0.240) among protocols. While exam duration differed substantially (all p ≤ 0.016), the lowest scan time was recorded for high-pitch protocols (4.3 ± 1.0 s) and the highest for low-pitch protocols (43.6 ± 15.4 s). The combination of high helical pitch and short gantry rotation times produced the lowest perceived image quality (intraclass correlation coefficient 0.866; 95% confidence interval 0.807-0.910; p < 0.001) and highest noise. Raw data size increased with acquisition time (15.4 ± 5.0 to 235.0 ± 83.5 GByte; p ≤ 0.013). Rotation time and pitch factor have considerable influence on image quality in UHR-PCCT and must therefore be chosen deliberately for different musculoskeletal imaging tasks. In examinations with long acquisition times, raw data size increases considerably, consequently limiting clinical applicability for larger scan volumes.
Collapse
|
4
|
Three-Dimensional Visualization of Shunt Valves with Photon Counting CT and Comparison to Traditional X-ray in a Simple Phantom Model. Tomography 2024; 10:543-553. [PMID: 38668400 PMCID: PMC11054214 DOI: 10.3390/tomography10040043] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/20/2024] [Revised: 04/09/2024] [Accepted: 04/11/2024] [Indexed: 04/29/2024] Open
Abstract
This study introduces an application of innovative medical technology, Photon Counting Computer Tomography (PC CT) with novel detectors, for the assessment of shunt valves. PC CT technology offers enhanced visualization capabilities, especially for small structures, and opens up new possibilities for detailed three-dimensional imaging. Shunt valves are implanted under the skin and redirect excess cerebrospinal fluid, for example, to the abdominal cavity through a catheter. They play a vital role in regulating cerebrospinal fluid drainage in various pathologies, which can lead to hydrocephalus. Accurate imaging of shunt valves is essential to assess the rate of drainage, as their precise adjustment is a requirement for optimal patient care. This study focused on two adjustable shunt valves, the proGAV 2.0® and M. blue® (manufactured by Miethke, Potsdam, Germany). A comprehensive comparative analysis of PC CT and traditional X-ray techniques was conducted to explore this cutting-edge technology and it demonstrated that routine PC CT can efficiently assess shunt valves' adjustments. This technology shows promise in enhancing the accurate management of shunt valves used in settings where head scans are already frequently required, such as in the treatment of hydrocephalus.
Collapse
|
5
|
Ultra-low-dose photon-counting CT of paranasal sinus: an in vivo comparison of radiation dose and image quality to cone-beam CT. Dentomaxillofac Radiol 2024; 53:103-108. [PMID: 38330501 DOI: 10.1093/dmfr/twad010] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/29/2023] [Revised: 10/29/2023] [Accepted: 11/16/2023] [Indexed: 02/10/2024] Open
Abstract
PURPOSE This study investigated the differences in subjective and objective image parameters as well as dose exposure of photon-counting CT (PCCT) compared to cone-beam CT (CBCT) in paranasal sinus imaging for the assessment of rhinosinusitis and sinonasal anatomy. METHODS This single-centre retrospective study included 100 patients, who underwent either clinically indicated PCCT or CBCT of the paranasal sinus. Two blinded experienced ENT radiologists graded image quality and delineation of specific anatomical structures on a 5-point Likert scale. In addition, contrast-to-noise ratio (CNR) and applied radiation doses were compared among both techniques. RESULTS Image quality and delineation of bone structures in paranasal sinus PCCT was subjectively rated superior by both readers compared to CBCT (P < .001). CNR was significantly higher for photon-counting CT (P < .001). Mean effective dose for PCCT examinations was significantly lower than for CBCT (0.038 mSv ± 0.009 vs. 0.14 mSv ± 0.011; P < .001). CONCLUSION In a performance comparison of PCCT and a modern CBCT scanner in paranasal sinus imaging, we demonstrated that first-use PCCT in clinical routine provides higher subjective image quality accompanied by higher CNR at close to a quarter of the dose exposure compared to CBCT.
Collapse
|
6
|
A New Iterative Metal Artifact Reduction Algorithm for Both Energy-Integrating and Photon-Counting CT Systems. Invest Radiol 2024:00004424-990000000-00190. [PMID: 38193772 DOI: 10.1097/rli.0000000000001055] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/10/2024]
Abstract
OBJECTIVES The aim of this study was to introduce and evaluate a new metal artifact reduction framework (iMARv2) that addresses the drawbacks (residual artifacts after correction and user preferences for image quality) associated with the current clinically applied iMAR. MATERIALS AND METHODS A new iMARv2 has been introduced, combining the current iMAR with new modular components to remove residual metal artifacts after image correction. The postcorrection image impression is adjustable with user-selectable strength settings. Phantom scans from an energy-integrating and a photon-counting detector CT were used to assess image quality, including a Gammex phantom and anthropomorphic phantoms. In addition, 36 clinical cases (with metallic implants such as dental fillings, hip replacements, and spinal screws) were reconstructed and evaluated in a blinded and randomized reader study. RESULTS The Gammex phantom showed lower HU errors compared with the uncorrected image at almost all iMAR and iMARv2 settings evaluated, with only minor differences between iMAR and the different iMARv2 settings. In addition, the anthropomorphic phantoms showed a trend toward lower errors with higher iMARv2 strength settings. On average, the iMARv2 strength 3 performed best of all the clinical reconstructions evaluated, with a significant increase in diagnostic confidence and decrease in artifacts. All hip and dental cases showed a significant increase in diagnostic confidence and decrease in artifact strength, and the improvements from iMARv2 in the dental cases were significant compared with iMAR. There were no significant improvements in the spine. CONCLUSIONS This work has introduced and evaluated a new method for metal artifact reduction and demonstrated its utility in routine clinical datasets. The greatest improvements were seen in dental fillings, where iMARv2 significantly improved image quality compared with conventional iMAR.
Collapse
|
7
|
Advances in metal artifact reduction in CT images: A review of traditional and novel metal artifact reduction techniques. Eur J Radiol 2024; 170:111276. [PMID: 38142571 DOI: 10.1016/j.ejrad.2023.111276] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/02/2023] [Revised: 12/14/2023] [Accepted: 12/18/2023] [Indexed: 12/26/2023]
Abstract
Metal artifacts degrade CT image quality, hampering clinical assessment. Numerous metal artifact reduction methods are available to improve the image quality of CT images with metal implants. In this review, an overview of traditional methods is provided including the modification of acquisition and reconstruction parameters, projection-based metal artifact reduction techniques (MAR), dual energy CT (DECT) and the combination of these techniques. Furthermore, the additional value and challenges of novel metal artifact reduction techniques that have been introduced over the past years are discussed such as photon counting CT (PCCT) and deep learning based metal artifact reduction techniques.
Collapse
|
8
|
Photon-counting computed tomography - clinical application in oncological, cardiovascular, and pediatric radiology. ROFO-FORTSCHR RONTG 2024; 196:25-35. [PMID: 37793417 DOI: 10.1055/a-2119-5802] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/06/2023]
Abstract
BACKGROUND Photon-counting detector computed tomography (PCD-CT) is a promising new technology with the potential to fundamentally change workflows in the daily routine and provide new quantitative imaging information to improve clinical decision-making and patient management. METHOD The contents of this review are based on an unrestricted literature search of PubMed and Google Scholar using the search terms "photon-counting CT", "photon-counting detector", "spectral CT", "computed tomography" as well as on the authors' own experience. RESULTS The fundamental difference with respect to the currently established energy-integrating CT detectors is that PCD-CT allows for the counting of every single photon at the detector level. Based on the identified literature, PCD-CT phantom measurements and initial clinical studies have demonstrated that the new technology allows for improved spatial resolution, reduced image noise, and new possibilities for advanced quantitative image postprocessing. CONCLUSION For clinical practice, the potential benefits include fewer beam hardening artifacts, a radiation dose reduction, and the use of new or combinations of contrast agents. In particular, critical patient groups such as oncological, cardiovascular, lung, and head & neck as well as pediatric patient collectives benefit from the clinical advantages. KEY POINTS · Photon-counting computed tomography (PCD-CT) is being used for the first time in routine clinical practice, enabling a significant dose reduction in critical patient populations such as oncology, cardiology, and pediatrics.. · Compared to conventional CT, PCD-CT enables a reduction in electronic image noise.. · Due to the spectral data sets, PCD-CT enables fully comprehensive post-processing applications.. CITATION FORMAT · Hagen F, Soschynski M, Weis M et al. Photon-counting computed tomography - clinical application in oncological, cardiovascular, and pediatric radiology. Fortschr Röntgenstr 2024; 196: 25 - 34.
Collapse
|
9
|
Multimodality imaging in patients with implantable loop recorders: Tips and tricks. Hellenic J Cardiol 2023:S1109-9666(23)00227-0. [PMID: 38096953 DOI: 10.1016/j.hjc.2023.12.001] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/27/2023] [Accepted: 12/09/2023] [Indexed: 12/26/2023] Open
Abstract
An implantable loop recorder (ILR) is a leadless rectangular device used for prolonged electrocardiographic monitoring for up to 3 years. This miniaturized device, inserted subcutaneously, allows clinicians to investigate possible cardiac rhythm disturbances in patients suffering from recurrent unexplained syncope. As the age of the population increases rapidly and the number of ILR patients amplifies, the clinical significance of ILRs is undeniable. Although radioopaque and easily seen on plain chest radiographs and other imaging modalities, ILRs may represent a challenge for clinicians and radiologists to recognize their classic appearance and differentiate them from numerous other cardiac devices. This article aims to summarize current literature on ILRs, their basic function, types, and indications for implantation, but most of all, it aims to familiarize clinicians and radiologists with common imaging features of these devices, safety issues, and artifact-reducing methods. Specifically, this review discusses the typical appearance of ILRs on major diagnostic imaging modalities, including chest X-ray, mammography, ultrasonography, computed tomography, and magnetic resonance imaging (MRI). Furthermore, optimization strategies to mitigate image artifacts and safety issues regarding MRI are discussed.
Collapse
|
10
|
Spectral photon-counting CT: Image quality evaluation using a metal-containing bovine bone specimen. Eur J Radiol 2023; 168:111110. [PMID: 37788519 DOI: 10.1016/j.ejrad.2023.111110] [Citation(s) in RCA: 1] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/21/2023] [Revised: 09/10/2023] [Accepted: 09/22/2023] [Indexed: 10/05/2023]
Abstract
PURPOSE To find the optimal imaging parameters for a photon-counting detector CT (PCD-CT) and to compare it to an energy-integrating detector CT (EID-CT) in terms of image quality and metal artefact severity using a metal-containing bovine knee specimen. METHODS A bovine knee with a stainless-steel plate and screws was imaged in a whole-body research PCD-CT at 120 kV and 140 kV and in an EID dual-source CT (DSCT) at Sn150 kV and 80/Sn150 kV. PCD-CT virtual monoenergetic 72 and 150 keV images and EID-CT images processed with and without metal artefact reduction algorithms (iMAR) were compared. Four radiologists rated the visualisation of bony structures and metal artefact severity. The Friedman test and Wilcoxon signed-rank test with Bonferroni's correction were used. P-values of ≤ 0.0001 were considered statistically significant. Distributions of HU values of regions of interest (ROIs) in artefact-affected areas were analysed. RESULTS PCD-CT 140 kV 150 keV images received the highest scores and were significantly better than EID-CT Sn150 kV images. PCD-CT 72 keV images were rated significantly lower than all the others. HU-value variation was larger in the 120 kV and the 72 keV images. The ROI analysis revealed no large difference between scanners regarding artefact severity. CONCLUSION PCD-CT 140 kV 150 keV images of a metal-containing bovine knee specimen provided the best image quality. They were superior to, or as good as, the best EID-CT images; even without the presumed advantage of tin filter and metal artefact reduction algorithms. PCD-CT is a promising method for reducing metal artefacts.
Collapse
|
11
|
Photon-Counting Computed Tomography (PC-CT) of the spine: impact on diagnostic confidence and radiation dose. Eur Radiol 2023; 33:5578-5586. [PMID: 36890304 PMCID: PMC10326119 DOI: 10.1007/s00330-023-09511-5] [Citation(s) in RCA: 10] [Impact Index Per Article: 10.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/22/2022] [Revised: 01/23/2023] [Accepted: 02/10/2023] [Indexed: 03/10/2023]
Abstract
OBJECTIVES Computed tomography (CT) is employed to evaluate surgical outcome after spinal interventions. Here, we investigate the potential of multispectral photon-counting computed tomography (PC-CT) on image quality, diagnostic confidence, and radiation dose compared to an energy-integrating CT (EID-CT). METHODS In this prospective study, 32 patients underwent PC-CT of the spine. Data was reconstructed in two ways: (1) standard bone kernel with 65-keV (PC-CTstd) and (2) 130-keV monoenergetic images (PC-CT130 keV). Prior EID-CT was available for 17 patients; for the remaining 15, an age-, sex-, and body mass index-matched EID-CT cohort was identified. Image quality (5-point Likert scales on overall, sharpness, artifacts, noise, diagnostic confidence) of PC-CTstd and EID-CT was assessed by four radiologists independently. If metallic implants were present (n = 10), PC-CTstd and PC-CT130 keV images were again assessed by 5-point Likert scales by the same radiologists. Hounsfield units (HU) were measured within metallic artifact and compared between PC-CTstd and PC-CT130 keV. Finally, the radiation dose (CTDIvol) was evaluated. RESULTS Sharpness was rated significantly higher (p = 0.009) and noise significantly lower (p < 0.001) in PC-CTstd vs. EID-CT. In the subset of patients with metallic implants, reading scores for PC-CT130 keV revealed superior ratings vs. PC-CTstd for image quality, artifacts, noise, and diagnostic confidence (all p < 0.001) accompanied by a significant increase of HU values within the artifact (p < 0.001). Radiation dose was significantly lower for PC-CT vs. EID-CT (mean CTDIvol: 8.83 vs. 15.7 mGy; p < 0.001). CONCLUSIONS PC-CT of the spine with high-kiloelectronvolt reconstructions provides sharper images, higher diagnostic confidence, and lower radiation dose in patients with metallic implants. KEY POINTS • Compared to energy-integrating CT, photon-counting CT of the spine had significantly higher sharpness and lower image noise while radiation dose was reduced by 45%. • In patients with metallic implants, virtual monochromatic photon-counting images at 130 keV were superior to standard reconstruction at 65 keV in terms of image quality, artifacts, noise, and diagnostic confidence.
Collapse
|
12
|
Dual Source Photon-Counting Computed Tomography-Part II: Clinical Overview of Neurovascular Applications. J Clin Med 2023; 12:jcm12113626. [PMID: 37297821 DOI: 10.3390/jcm12113626] [Citation(s) in RCA: 4] [Impact Index Per Article: 4.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/16/2023] [Revised: 05/15/2023] [Accepted: 05/18/2023] [Indexed: 06/12/2023] Open
Abstract
Photon-counting detector (PCD) is a novel computed tomography detector technology (photon-counting computed tomography-PCCT) that presents many advantages in the neurovascular field, such as increased spatial resolution, reduced radiation exposure, and optimization of the use of contrast agents and material decomposition. In this overview of the existing literature on PCCT, we describe the physical principles, the advantages and the disadvantages of conventional energy integrating detectors and PCDs, and finally, we discuss the applications of the PCD, focusing specifically on its implementation in the neurovascular field.
Collapse
|
13
|
Abstract
Photon-counting detector (PCD) CT represents the most recent generational advance in CT technology. PCD CT has the potential to reduce image noise, improve spatial resolution and contrast resolution, and provide multispectral capability, all of which may be achieved with an overall decrease in the radiation dose. These effects may be used to reduce the iodinated contrast media dose and potentially obtain multiphase images through a single-acquisition technique. The benefits of PCD CT have previously been shown primarily in phantoms and adult patients. This article describes the application of PCD CT in children, as illustrated by clinical examples from a commercially available PCD CT system.
Collapse
|
14
|
Metal artifacts and artifact reduction of neurovascular coils in photon-counting detector CT versus energy-integrating detector CT - in vitro comparison of a standard brain imaging protocol. Eur Radiol 2023; 33:803-811. [PMID: 35986773 PMCID: PMC9889475 DOI: 10.1007/s00330-022-09073-y] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/06/2022] [Revised: 06/11/2022] [Accepted: 07/27/2022] [Indexed: 02/04/2023]
Abstract
OBJECTIVES Photon-counting detector computed tomography (PCD-CT) is a promising new technique for CT imaging. The aim of the present study was the in vitro comparison of coil-related artifacts in PCD-CT and conventional energy-integrating detector CT (EID-CT) using a comparable standard brain imaging protocol before and after metal artifact reduction (MAR). METHODS A nidus-shaped rubber latex, resembling an aneurysm of the cerebral arteries, was filled with neurovascular platinum coils and inserted into a brain imaging phantom. Image acquisition and reconstruction were repeatedly performed for PCD-CT and EID-CT (n = 10, respectively) using a standard brain imaging protocol. Moreover, linear interpolation MAR was performed for PCD-CT and EID-CT images. The degree of artifacts was analyzed quantitatively (standard deviation in a donut-shaped region of interest) and qualitatively (5-point scale analysis). RESULTS Quantitative and qualitative analysis demonstrated a lower degree of metal artifacts in the EID-CT images compared to the total-energy PCD-CT images (e.g., 82.99 ± 7.89 Hounsfield units (HU) versus 90.35 ± 6.28 HU; p < 0.001) with no qualitative difference between the high-energy bin PCD-CT images and the EID-CT images (4.18 ± 0.37 and 3.70 ± 0.64; p = 0.575). After MAR, artifacts were more profoundly reduced in the PCD-CT images compared to the EID-CT images in both analyses (e.g., 2.35 ± 0.43 and 3.18 ± 0.34; p < 0.001). CONCLUSION PCD-CT in combination with MAR have the potential to provide an improved option for reduction of coil-related artifacts in cerebral imaging in this in vitro study. KEY POINTS • Photon-counting detector CT produces more artifacts compared to energy-integrating detector CT without metal artifact reduction in cerebral in vitro imaging after neurovascular coil-embolization. • Spectral information of PCD-CT provides the potential for new post-processing techniques, since the coil-related artifacts were lower in PCD-CT images compared to EID-CT images after linear interpolation metal artifact reduction in this in vitro study.
Collapse
|
15
|
Low-Dose CT Imaging of the Pelvis in Follow-up Examinations-Significant Dose Reduction and Impact of Tin Filtration: Evaluation by Phantom Studies and First Systematic Retrospective Patient Analyses. Invest Radiol 2022; 57:789-801. [PMID: 35776429 DOI: 10.1097/rli.0000000000000898] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/26/2022]
Abstract
OBJECTIVES Low-dose (LD) computed tomography (CT) is still rarely used in musculoskeletal (MSK) radiology. This study evaluates the potentials of LD CT for follow-up pelvic imaging with special focus on tin filtration (Sn) technology for normal and obese patients with and without metal implants. MATERIALS AND METHODS In a phantom study, 5 different LD and normal-dose (ND) CT protocols with and without tin filtration were tested using a normal and an obese phantom. Iterative reconstruction (IR) and filtered back projection (FBP) were used for CT image reconstruction. In a subsequent retrospective patient study, ND CT images of 45 patients were compared with follow-up tin-filtered LD CT images with a 90% dose reduction. Sixty-four percent of patients contained metal implants at the follow-up examination. Computed tomography images were objectively (image noise, contrast-to-noise ratio [CNR], dose-normalized contrast-to-noise ratio [CNRD]) and subjectively, using a 6-point Likert score, evaluated. In addition, the figure of merit was calculated. For group comparisons, paired t tests, Wilcoxon signed rank test, analysis of variance, or Kruskal-Wallis tests were used, where applicable. RESULTS The LD Sn protocol with 67% dose reduction resulted in equal values in qualitative (Likert score) and quantitative image analysis (image noise) compared with the ND protocol in the phantom study. For follow-up examinations, dose could be reduced up to 90% by using Sn LD CT scans without impairment in the clinical study. However, metal implants resulted in a mild impairment of Sn LD as well as ND CT images. Cancellous bone ( P < 0.001) was assessed worse and cortical bone ( P = 0.063) equally in Sn LD CT images compared with ND CT images. Figure of merit values were significant ( P ≤ 0.02) lower and hence better in Sn LD as in ND protocols. Obese patients benefited in particular from tin filtration in LD MSK imaging in terms of image noise and CNR ( P ≤ 0.05). CONCLUSIONS Low-dose CT scans with tin filtration allow maximum dose reduction while maintaining high image quality for certain clinical purposes, for example, follow-up examinations, especially metal implant position, material loosening, and consolidation controls. Overweight patients benefit particularly from tin filter technology. Although metal implants decrease image quality in ND as well as in Sn LD CT images, this is not a relevant limitation for assessability.
Collapse
|
16
|
Computer tomography and magnetic resonance for multimodal imaging of fossils and mummies. Magn Reson Imaging 2022; 94:7-17. [PMID: 36084902 DOI: 10.1016/j.mri.2022.08.019] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/07/2022] [Revised: 08/26/2022] [Accepted: 08/31/2022] [Indexed: 11/24/2022]
Abstract
The study of fossils and mummies has largely benefited from the use of modern noninvasive and nondestructive imaging technologies and represents a fast developing area. In this review, we describe the emerging role of imaging based on Magnetic Resonance (MR) and Computer Tomography (CT) employed for the study of ancient remains and mummies. For each methodology, the state of the art in paleoradiology applications is described, by emphasizing new technologies developed in the field of both CT, such as micro- and nano-CT, dual-energy and multi-energy CT, and MR, with the description of novel dedicated sequences, radiofrequency coils and gradients. The complementarity of CT and MR in paleoradiology is also discussed, by pointing out what MR provides in addition to CT, with an overview on the state of the art of emerging strategies in the use of CT/MR combination for the study of a sample following a multimodal integrated approach.
Collapse
|
17
|
Iterative metal artifact reduction on a clinical photon counting system—technical possibilities and reconstruction selection for optimal results dependent on the metal scenario. Phys Med Biol 2022; 67. [DOI: 10.1088/1361-6560/ac71f0] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/09/2022] [Accepted: 05/20/2022] [Indexed: 11/12/2022]
Abstract
Abstract
Objective. To give an overview about technical possibilities for metal artifact reduction of the first clinical photon-counting CT system and assess optimal reconstruction settings in a phantom study, assessing monoenergetic imaging (VMI) and iterative metal artifact reduction (iMAR). Approach. Scans were performed with 120 kV and Sn140 kV on the first clinical photon-counting detector CT scanner. To quantify artifact reduction, anthropomorphic phantoms (hip, dental, spine, neuro) were assessed, in addition to a tissue characterization phantom (Gammex) to quantify the HU restoration accuracy, all with removable metal inserts. Each setup was reconstructed with and without dedicated iMAR, and VMIs were computed in 10 keV steps from 40 keV (60 keV at Sn140 kV) to 190 keV for all setups (ground truth and metal with and without iMAR). To find the optimal energy, pixel-wise errors were computed in relevant ROIs in water-equivalent tissue around the metal in each phantom setup. To assess HU restoration potential, measurements were performed in the Gammex phantom’s inserts. Main results. Large metal objects (hip head) or metal with high atomic numbers (dental and neuro) do not benefit from higher-energetic reconstructions. The hip shaft (large, low atomic number) comprises a lower base artifact level than the head, still without an energetic optimum. Within the spine (short penetration length, low atomic number) an energy optimum could be identified for both spectra (100 keV for 120 kV and 120 keV for Sn140 kV). The Gammex showed best HU restoration at 100 keV for 120 kV and at 110 keV for Sn140 kV. In all cases, additional iMAR reduced the base artifact level. Significance. This study shows that a novel photon-counting CT system has the capability to reduce metal artifacts in metal types with low atomic number and low penetration length by applying VMI. For all other metal types, additional iMAR is required to reduce artifacts.
Collapse
|
18
|
Empirical scatter correction (ESC): CBCT scatter artifact reduction without prior information. Med Phys 2022; 49:4566-4584. [PMID: 35390181 DOI: 10.1002/mp.15656] [Citation(s) in RCA: 2] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/17/2021] [Revised: 03/24/2022] [Accepted: 03/27/2022] [Indexed: 11/07/2022] Open
Abstract
BACKGROUND The image quality of cone-beam CT (CBCT) scans severely suffers from scattered radiation if no countermeasures are taken. Scatter artifacts may induce cupping and streak artifacts and lead to a reduced image contrast and wrong CT values of the reconstructed volumes. Established software-based approaches for a correction of scattered radiation typically rely on prior knowledge of the CT system, scan parameters, the scanned object, or all of the aforementioned. PURPOSE This study proposes a simple and effective post-processing software-based correction method of scatter artifacts in CBCT scans without specific prior knowledge. METHODS We propose the empirical scatter correction (ESC) which generates scatter-like basis images from each projection image by convolution operations. A linear combination of these basis images is subtracted from the original projection image. The logarithm is taken and an FDK reconstruction is performed. The coefficients needed for the linear combination are determined automatically by a downhill simplex algorithm such that the resulting reconstructed images show no scatter artifacts. We demonstrate the potential of ESC by correcting simulated volumes with Monte Carlo scatter artifacts, a head phantom scan performed on our table-top CBCT, and a pelvis scan from a Varian Edge CBCT scanner. RESULTS ESC is able to improve the image quality of CBCT scans which is shown on the basis of our simulations and on measured data. For a simulated head CT, the CT value difference to the scatter-free reference image was as low as -6 HU after using ESC whereas the uncorrected data deviated by more than -200 HU from the reference data. Simulations of thorax and abdomen CT scans show that although scatter artifacts are not fully removed, anatomical features which were hard to discover prior to the correction become clearly visible and better segmentable with ESC. Similar results are obtained in the phantom measurement where a comparison to a slit scan of our head phantom shows only small differences. The CT values in soft tissue are improved in this measurement, as well. In soft tissue areas with severe scatter artifacts the CT values agree well with those of the slit scan (difference to slit scan: 35 HU corrected, -289 HU uncorrected). Scatter artifacts in measured patient data can also be reduced using the proposed empirical scatter correction. The results are comparable to those achieved with designated correction algorithms installed on the Varian Edge CBCT system. CONCLUSIONS ESC allows to reduce artifacts caused by patient scatter solely based on the projection data. This article is protected by copyright. All rights reserved.
Collapse
|
19
|
Feasibility study of portable multi-energy computed tomography with photon-counting detector for preclinical and clinical applications. Sci Rep 2021; 11:22731. [PMID: 34815501 PMCID: PMC8611013 DOI: 10.1038/s41598-021-02210-5] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/07/2021] [Accepted: 11/08/2021] [Indexed: 11/08/2022] Open
Abstract
In this study, preclinical experiments were performed with an in-house developed prototypal photon-counting detector computed tomography (PCD CT) system. The performance of the system was compared with the conventional energy-integrating detector (EID)-based CT, concerning the basic image quality biomarkers and the respective capacities for material separation. The pre- and the post-contrast axial images of a canine brain captured by the PCD CT and EID CT systems were found to be visually similar. Multi-energy images were acquired using the PCD CT system, and machine learning-based material decomposition was performed to segment the white and gray matters for the first time in soft tissue segmentation. Furthermore, to accommodate clinical applications that require high resolution acquisitions, a small, native, high-resolution (HR) detector was implemented on the PCD CT system, and its performance was evaluated based on animal experiments. The HR acquisition mode improved the spatial resolution and delineation of the fine structures in the canine's nasal turbinates compared to the standard mode. Clinical applications that rely on high-spatial resolution expectedly will also benefit from this resolution-enhancing function. The results demonstrate the potential impact on the brain tissue segmentation, improved detection of the liver tumors, and capacity to reconstruct high-resolution images both preclinically and clinically.
Collapse
|