Plähn NMJ, Poli S, Peper ES, Açikgöz BC, Kreis R, Ganter C, Bastiaansen JAM. Getting the phase consistent: The importance of phase description in balanced steady-state free precession MRI of multi-compartment systems. Magn Reson Med 2024; 92:215-225. [PMID: 38321594 DOI: 10.1002/mrm.30033] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/16/2023] [Revised: 01/09/2024] [Accepted: 01/12/2024] [Indexed: 02/08/2024]
Abstract
PURPOSE Determine the correct mathematical phase description for balanced steady-state free precession (bSSFP) signals in multi-compartment systems. THEORY AND METHODS Based on published bSSFP signal models, different phase descriptions can be formulated: one predicting the presence and the other predicting the absence of destructive interference effects in multi-compartment systems. Numerical simulations of bSSFP signals of water and acetone were performed to evaluate the predictions of these different phase descriptions. For experimental validation, bSSFP profiles were measured at 3T using phase-cycled bSSFP acquisitions performed in a phantom containing mixtures of water and acetone, which replicates a system with two signal components. Localized single voxel MRS was performed at 7T to determine the relative chemical shift of the acetone-water mixtures. RESULTS Based on the choice of phase description, the simulated bSSFP profiles of water-acetone mixtures varied significantly, either displaying or lacking destructive interference effects, as predicted theoretically. In phantom experiments, destructive interference was consistently observed in the measured bSSFP profiles of water-acetone mixtures, supporting the theoretical description that predicts such interference effects. The connection between the choice of phase description and predicted observation enables unambiguous experimental identification of the correct phase description for multi-compartment bSSFP profiles, which is consistent with the Bloch equations. CONCLUSION The study emphasizes that consistent phase descriptions are crucial for accurately describing multi-compartment bSSFP signals, as incorrect phase descriptions result in erroneous predictions.
Collapse
Affiliation(s)
- Nils M J Plähn
- Department of Diagnostic, Interventional and Pediatric Radiology (DIPR), Inselspital, Bern University Hospital, University of Bern, Bern, Switzerland
- Translation Imaging Center (TIC), Swiss Institute for Translational and Entrepreneurial Medicine, Bern, Switzerland
- Graduate School for Cellular and Biomedical Sciences, University of Bern, Bern, Switzerland
| | - Simone Poli
- Translation Imaging Center (TIC), Swiss Institute for Translational and Entrepreneurial Medicine, Bern, Switzerland
- Graduate School for Cellular and Biomedical Sciences, University of Bern, Bern, Switzerland
- MR Methodology, Department for Diagnostic and Interventional Neuroradiology, University of Bern, Bern, Switzerland
| | - Eva S Peper
- Department of Diagnostic, Interventional and Pediatric Radiology (DIPR), Inselspital, Bern University Hospital, University of Bern, Bern, Switzerland
- Translation Imaging Center (TIC), Swiss Institute for Translational and Entrepreneurial Medicine, Bern, Switzerland
| | - Berk C Açikgöz
- Department of Diagnostic, Interventional and Pediatric Radiology (DIPR), Inselspital, Bern University Hospital, University of Bern, Bern, Switzerland
- Translation Imaging Center (TIC), Swiss Institute for Translational and Entrepreneurial Medicine, Bern, Switzerland
- Graduate School for Cellular and Biomedical Sciences, University of Bern, Bern, Switzerland
| | - Roland Kreis
- Translation Imaging Center (TIC), Swiss Institute for Translational and Entrepreneurial Medicine, Bern, Switzerland
- MR Methodology, Department for Diagnostic and Interventional Neuroradiology, University of Bern, Bern, Switzerland
- Department for Biomedical Research, University of Bern, Bern, Switzerland
| | - Carl Ganter
- Department of Diagnostic and Interventional Radiology, TUM School of Medicine and Health, Klinikum rechts der Isar, Technical University of Munich, Munich, Germany
| | - Jessica A M Bastiaansen
- Department of Diagnostic, Interventional and Pediatric Radiology (DIPR), Inselspital, Bern University Hospital, University of Bern, Bern, Switzerland
- Translation Imaging Center (TIC), Swiss Institute for Translational and Entrepreneurial Medicine, Bern, Switzerland
| |
Collapse
|
2
|
Rossi GMC, Mackowiak ALC, Açikgöz BC, Pierzchała K, Kober T, Hilbert T, Bastiaansen JAM. SPARCQ: A new approach for fat fraction mapping using asymmetries in the phase-cycled balanced SSFP signal profile. Magn Reson Med 2023; 90:2348-2361. [PMID: 37496187 DOI: 10.1002/mrm.29813] [Citation(s) in RCA: 1] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/03/2023] [Revised: 06/19/2023] [Accepted: 07/12/2023] [Indexed: 07/28/2023]
Abstract
PURPOSE To develop SPARCQ (Signal Profile Asymmetries for Rapid Compartment Quantification), a novel approach to quantify fat fraction (FF) using asymmetries in the phase-cycled balanced SSFP (bSSFP) profile. METHODS SPARCQ uses phase-cycling to obtain bSSFP frequency profiles, which display asymmetries in the presence of fat and water at certain TRs. For each voxel, the measured signal profile is decomposed into a weighted sum of simulated profiles via multi-compartment dictionary matching. Each dictionary entry represents a single-compartment bSSFP profile with a specific off-resonance frequency and relaxation time ratio. Using the results of dictionary matching, the fractions of the different off-resonance components are extracted for each voxel, generating quantitative maps of water and FF and banding-artifact-free images for the entire image volume. SPARCQ was validated using simulations, experiments in a water-fat phantom and in knees of healthy volunteers. Experimental results were compared with reference proton density FFs obtained with 1 H-MRS (phantoms) and with multiecho gradient-echo MRI (phantoms and volunteers). SPARCQ repeatability was evaluated in six scan-rescan experiments. RESULTS Simulations showed that FF quantification is accurate and robust for SNRs greater than 20. Phantom experiments demonstrated good agreement between SPARCQ and gold standard FFs. In volunteers, banding-artifact-free quantitative maps and water-fat-separated images obtained with SPARCQ and ME-GRE demonstrated the expected contrast between fatty and non-fatty tissues. The coefficient of repeatability of SPARCQ FF was 0.0512. CONCLUSION SPARCQ demonstrates potential for fat quantification using asymmetries in bSSFP profiles and may be a promising alternative to conventional FF quantification techniques.
Collapse
Affiliation(s)
- Giulia M C Rossi
- Department of Diagnostic, Interventional and Pediatric Radiology (DIPR), Inselspital, Bern University Hospital, University of Bern, Bern, Switzerland
- Translational Imaging Center, Swiss Institute for Translational and Entrepreneurial Medicine, Bern, Switzerland
- Department of Diagnostic and Interventional Radiology, Lausanne University Hospital and University of Lausanne, Lausanne, Switzerland
| | - Adèle L C Mackowiak
- Department of Diagnostic, Interventional and Pediatric Radiology (DIPR), Inselspital, Bern University Hospital, University of Bern, Bern, Switzerland
- Translational Imaging Center, Swiss Institute for Translational and Entrepreneurial Medicine, Bern, Switzerland
- Department of Diagnostic and Interventional Radiology, Lausanne University Hospital and University of Lausanne, Lausanne, Switzerland
| | - Berk Can Açikgöz
- Department of Diagnostic, Interventional and Pediatric Radiology (DIPR), Inselspital, Bern University Hospital, University of Bern, Bern, Switzerland
- Translational Imaging Center, Swiss Institute for Translational and Entrepreneurial Medicine, Bern, Switzerland
| | - Katarzyna Pierzchała
- CIBM Center for Biomedical Imaging, Lausanne, Switzerland
- Animal Imaging and Technology, Ecole Polytechnique Fédérale de Lausanne, Lausanne, Switzerland
| | - Tobias Kober
- Department of Diagnostic and Interventional Radiology, Lausanne University Hospital and University of Lausanne, Lausanne, Switzerland
- Advanced Clinical Imaging Technology, Siemens Healthineers International AG, Lausanne, Switzerland
- LTS5, École Polytechnique Fédérale de Lausanne (EPFL), Lausanne, Switzerland
| | - Tom Hilbert
- Department of Diagnostic and Interventional Radiology, Lausanne University Hospital and University of Lausanne, Lausanne, Switzerland
- Advanced Clinical Imaging Technology, Siemens Healthineers International AG, Lausanne, Switzerland
- LTS5, École Polytechnique Fédérale de Lausanne (EPFL), Lausanne, Switzerland
| | - Jessica A M Bastiaansen
- Department of Diagnostic, Interventional and Pediatric Radiology (DIPR), Inselspital, Bern University Hospital, University of Bern, Bern, Switzerland
- Translational Imaging Center, Swiss Institute for Translational and Entrepreneurial Medicine, Bern, Switzerland
| |
Collapse
|
3
|
Hoff MN, Xiang QS, Cross NM, Hippe D, Andre JB. Motion resilience of the balanced steady-state free precession geometric solution. Magn Reson Med 2022; 89:192-204. [PMID: 36093906 DOI: 10.1002/mrm.29438] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/21/2022] [Revised: 07/26/2022] [Accepted: 08/11/2022] [Indexed: 11/06/2022]
Abstract
PURPOSE Many MRI sequences are sensitive to motion and its associated artifacts. The linearized geometric solution (LGS), a balanced steady-state free precession (bSSFP) off-resonance signal demodulation technique, is evaluated with respect to motion artifact resilience. THEORY AND METHODS The mechanism and extent of LGS motion artifact resilience is examined in simulated, flow phantom, and in vivo clinical imaging. Motion artifact correction capabilities are decoupled from susceptibility artifact correction when feasible to permit controlled analysis of motion artifact correction when comparing the LGS with standard and phase-cycle-averaged (complex sum) bSSFP imaging. RESULTS Simulations reveal that the LGS demonstrates motion artifact reduction capabilities similar to standard clinical bSSFP imaging techniques, with slightly greater resilience in high SNR regions and for shorter-duration motion. Flow phantom experiments assert that the LGS reduces shorter-duration motion artifact error by ∼24%-65% relative to the complex sum, whereas reconstructions exhibit similar error reduction for constant motion. In vivo analysis demonstrates that in the internal auditory canal/orbits, the LGS was deemed to have less artifact in 24%/49% and similar artifact in 76%/51% of radiological assessments relative to the complex sum, and the LGS had less artifact in 97%/81% and similar artifact in 3%/16% of assessments relative to standard bSSFP. Only 2 of 63 assessments deemed the LGS inferior to either complex sum or standard bSSFP in terms of artifact reduction. CONCLUSION The LGS provides sufficient bSSFP motion artifact resilience to permit robust elimination of susceptibility artifacts, inspiring its use in a wide variety of applications.
Collapse
Affiliation(s)
- Michael N Hoff
- Department of Radiology and Biomedical Imaging, University of California San Francisco, San Francisco, California, USA
| | - Qing-San Xiang
- Department of Physics & Astronomy, University of British Columbia, Vancouver, British Columbia, Canada.,Department of Radiology, University of British Columbia, Vancouver, British Columbia, Canada
| | - Nathan M Cross
- Department of Radiology, University of Washington, Seattle, Washington, USA
| | - Daniel Hippe
- Clinical Biostatistics, Fred Hutchinson Cancer Research Center, Seattle, Washington, USA
| | - Jalal B Andre
- Department of Radiology, University of Washington, Seattle, Washington, USA
| |
Collapse
|
4
|
Kim KH, Seo S, Do WJ, Luu HM, Park SH. Varying undersampling directions for accelerating multiple acquisition magnetic resonance imaging. NMR IN BIOMEDICINE 2022; 35:e4572. [PMID: 34114253 DOI: 10.1002/nbm.4572] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 04/29/2020] [Revised: 05/27/2021] [Accepted: 05/27/2021] [Indexed: 06/12/2023]
Abstract
In this study, we propose a new sampling strategy for efficiently accelerating multiple acquisition MRI. The new sampling strategy is to obtain data along different phase-encoding directions across multiple acquisitions. The proposed sampling strategy was evaluated in multicontrast MR imaging (T1, T2, proton density) and multiple phase-cycled (PC) balanced steady-state free precession (bSSFP) imaging by using convolutional neural networks with central and random sampling patterns. In vivo MRI acquisitions as well as a public database were used to test the concept. Based on both visual inspection and quantitative analysis, the proposed sampling strategy showed better performance than sampling along the same phase-encoding direction in both multicontrast MR imaging and multiple PC-bSSFP imaging, regardless of sampling pattern (central, random) or datasets (public, retrospective and prospective in vivo). For the prospective in vivo applications, acceleration was performed by sampling along different phase-encoding directions at the time of acquisition with a conventional rectangular field of view, which demonstrated the advantage of the proposed sampling strategy in the real environment. Preliminary trials on compressed sensing (CS) also demonstrated improvement of CS with the proposed idea. Sampling along different phase-encoding directions across multiple acquisitions is advantageous for accelerating multiacquisition MRI, irrespective of sampling pattern or datasets, with further improvement through transfer learning.
Collapse
Affiliation(s)
- Ki Hwan Kim
- Department of Bio and Brain Engineering, Korea Advanced Institute of Science and Technology, Daejeon, South Korea
- Graduate School of Medical Science and Engineering, Korea Advanced Institute of Science and Technology, Daejeon, South Korea
| | - Sunghun Seo
- Department of Bio and Brain Engineering, Korea Advanced Institute of Science and Technology, Daejeon, South Korea
| | - Won-Joon Do
- Department of Bio and Brain Engineering, Korea Advanced Institute of Science and Technology, Daejeon, South Korea
| | - Huan Minh Luu
- Department of Bio and Brain Engineering, Korea Advanced Institute of Science and Technology, Daejeon, South Korea
| | - Sung-Hong Park
- Department of Bio and Brain Engineering, Korea Advanced Institute of Science and Technology, Daejeon, South Korea
- Graduate School of Medical Science and Engineering, Korea Advanced Institute of Science and Technology, Daejeon, South Korea
| |
Collapse
|
5
|
Keskin K, Yilmaz U, Cukur T. Constrained Ellipse Fitting for Efficient Parameter Mapping With Phase-Cycled bSSFP MRI. IEEE TRANSACTIONS ON MEDICAL IMAGING 2022; 41:14-26. [PMID: 34351856 DOI: 10.1109/tmi.2021.3102852] [Citation(s) in RCA: 3] [Impact Index Per Article: 1.5] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 06/13/2023]
Abstract
Balanced steady-state free precession (bSSFP) imaging enables high scan efficiency in MRI, but differs from conventional sequences in terms of elevated sensitivity to main field inhomogeneity and nonstandard [Formula: see text]-weighted tissue contrast. To address these limitations, multiple bSSFP images of the same anatomy are commonly acquired with a set of different RF phase-cycling increments. Joint processing of phase-cycled acquisitions serves to mitigate sensitivity to field inhomogeneity. Recently phase-cycled bSSFP acquisitions were also leveraged to estimate relaxation parameters based on explicit signal models. While effective, these model-based methods often involve a large number of acquisitions (N ≈ 10-16), degrading scan efficiency. Here, we propose a new constrained ellipse fitting method (CELF) for parameter estimation with improved efficiency and accuracy in phase-cycled bSSFP MRI. CELF is based on the elliptical signal model framework for complex bSSFP signals; and it introduces geometrical constraints on ellipse properties to improve estimation efficiency, and dictionary-based identification to improve estimation accuracy. CELF generates maps of [Formula: see text], [Formula: see text], off-resonance and on-resonant bSSFP signal by employing a separate [Formula: see text] map to mitigate sensitivity to flip angle variations. Our results indicate that CELF can produce accurate off-resonance and banding-free bSSFP maps with as few as N = 4 acquisitions, while estimation accuracy for relaxation parameters is notably limited by biases from microstructural sensitivity of bSSFP imaging.
Collapse
|
6
|
Bıyık E, Keskin K, Uh Dar S, Koç A, Çukur T. Factorized sensitivity estimation for artifact suppression in phase-cycled bSSFP MRI. NMR IN BIOMEDICINE 2020; 33:e4228. [PMID: 31985879 DOI: 10.1002/nbm.4228] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 03/06/2019] [Revised: 10/08/2019] [Accepted: 10/25/2019] [Indexed: 06/10/2023]
Abstract
OBJECTIVE Balanced steady-state free precession (bSSFP) imaging suffers from banding artifacts in the presence of magnetic field inhomogeneity. The purpose of this study is to identify an efficient strategy to reconstruct banding-free bSSFP images from multi-coil multi-acquisition datasets. METHOD Previous techniques either assume that a naïve coil-combination is performed a priori resulting in suboptimal artifact suppression, or that artifact suppression is performed for each coil separately at the expense of significant computational burden. Here we propose a tailored method that factorizes the estimation of coil and bSSFP sensitivity profiles for improved accuracy and/or speed. RESULTS In vivo experiments show that the proposed method outperforms naïve coil-combination and coil-by-coil processing in terms of both reconstruction quality and time. CONCLUSION The proposed method enables computationally efficient artifact suppression for phase-cycled bSSFP imaging with modern coil arrays. Rapid imaging applications can efficiently benefit from the improved robustness of bSSFP imaging against field inhomogeneity.
Collapse
Affiliation(s)
- Erdem Bıyık
- Department of Electrical Engineering, Stanford University, CA, USA
- Intelligent Data Analytics Research Program Department, Aselsan Research Center, Ankara, Turkey
- Department of Electrical and Electronics Engineering, Bilkent University, Ankara, Turkey
| | - Kübra Keskin
- Department of Electrical and Electronics Engineering, Bilkent University, Ankara, Turkey
- National Magnetic Resonance Research Center (UMRAM), Bilkent University, Ankara, Turkey
| | - Salman Uh Dar
- Department of Electrical and Electronics Engineering, Bilkent University, Ankara, Turkey
- National Magnetic Resonance Research Center (UMRAM), Bilkent University, Ankara, Turkey
| | - Aykut Koç
- Intelligent Data Analytics Research Program Department, Aselsan Research Center, Ankara, Turkey
- Department of Electrical and Electronics Engineering, Bilkent University, Ankara, Turkey
- National Magnetic Resonance Research Center (UMRAM), Bilkent University, Ankara, Turkey
| | - Tolga Çukur
- Department of Electrical and Electronics Engineering, Bilkent University, Ankara, Turkey
- National Magnetic Resonance Research Center (UMRAM), Bilkent University, Ankara, Turkey
- Neuroscience Program at Sabuncu Brain Research Center, Bilkent University, Ankara, Turkey
| |
Collapse
|
7
|
Robb JS, Hu C, Peters DC. Interleaved, undersampled radial multiple-acquisition steady-state free precession for improved left atrial cine imaging. Magn Reson Med 2019; 83:1721-1729. [PMID: 31605555 DOI: 10.1002/mrm.28036] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.2] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/29/2019] [Revised: 08/31/2019] [Accepted: 09/20/2019] [Indexed: 11/10/2022]
Abstract
PURPOSE Balanced steady-state free precession (bSSFP) left atrial (LA) cine suffers from off-resonance artifacts, particularly in the pulmonary veins (PVs). Linear combination or multiple-acquisition SSFP (MA-SSFP) effectively removes banding but greatly increases scan time. We hypothesized that MA-SSFP with interleaved radial undersampling, where each phase-cycling is acquired with an interleaved set of radial projections, would improve image quality of LA cine with a small increase of scan time and streak artefacts. METHODS Undersampled radial MA-SSFP with and without interleaving was compared with fully sampled radial bSSFP by means of simulations, phantoms, and in vivo imaging. Ten healthy subjects were imaged on a 3T scanner, with bSSFP and MA-SSFP cine of the left atrium, and B0-mapping. Images were assessed (1 = worst, 5 = best) by 2 independent readers, with respect to 5 qualitative criteria and apparent signal-to-noise ratio. RESULTS In healthy subjects, off-resonance differed from the right inferior PVs to the LA cavity by 163 Hz ± 73 Hz at 3T. Compared with fully sampled radial bSSFP, interleaved radial MA-SSFP significantly improved image quality with respect to off-resonance artifacts (3.8 ± 0.6 versus 2.3 ± 1.0; P = 0.005), PV conspicuity (2.8 ± 1.0 versus 4.3 ± 0.5; P = 0.005), and the number of visualized PVs (1.7 ± 0.4 versus 0.9 ± 0.7; P = 0.008), although with greater streak artifacts (3.4 ± 0.4 versus 4.9 ± 0.2; P = 0.004) and lower measured apparent signal-to-noise ratio (24 ± 9 versus 69 ± 36; P = 0.002). Flow artifacts were similar. Interleaved radial MA-SSFP reduced streaking artifacts and increased apparent signal-to-noise ratio versus noninterleaved radial. CONCLUSIONS Interleaved radial MA-SSFP cine reduces banding artifacts with an acceptable increase of scan time and streak artifacts. The proposed technique improves the LA and PV visualization in bSSFP cine imaging.
Collapse
Affiliation(s)
| | - Chenxi Hu
- School of Biomedical Engineering, Shanghai Jiao Tong University, Shanghai, China.,Department of Radiology and Biomedical Imaging, Yale School of Medicine, Yale University, New Haven, Connecticut
| | - Dana C Peters
- Department of Radiology and Biomedical Imaging, Yale School of Medicine, Yale University, New Haven, Connecticut
| |
Collapse
|
8
|
Senel LK, Kilic T, Gungor A, Kopanoglu E, Guven HE, Saritas EU, Koc A, Cukur T. Statistically Segregated k-Space Sampling for Accelerating Multiple-Acquisition MRI. IEEE TRANSACTIONS ON MEDICAL IMAGING 2019; 38:1701-1714. [PMID: 30640604 DOI: 10.1109/tmi.2019.2892378] [Citation(s) in RCA: 6] [Impact Index Per Article: 1.2] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 06/09/2023]
Abstract
A central limitation of multiple-acquisition magnetic resonance imaging (MRI) is the degradation in scan efficiency as the number of distinct datasets grows. Sparse recovery techniques can alleviate this limitation via randomly undersampled acquisitions. A frequent sampling strategy is to prescribe for each acquisition a different random pattern drawn from a common sampling density. However, naive random patterns often contain gaps or clusters across the acquisition dimension that, in turn, can degrade reconstruction quality or reduce scan efficiency. To address this problem, a statistically segregated sampling method is proposed for multiple-acquisition MRI. This method generates multiple patterns sequentially while adaptively modifying the sampling density to minimize k-space overlap across patterns. As a result, it improves incoherence across acquisitions while still maintaining similar sampling density across the radial dimension of k-space. Comprehensive simulations and in vivo results are presented for phase-cycled balanced steady-state free precession and multi-echo [Formula: see text]-weighted imaging. Segregated sampling achieves significantly improved quality in both Fourier and compressed-sensing reconstructions of multiple-acquisition datasets.
Collapse
|
9
|
Matsumoto K, Yokota H, Mukai H, Masuda Y, Uno T, Miyati T. Merging images with different central frequencies reduces banding artifacts in balanced steady-state free precession magnetic resonance cisternography. J Appl Clin Med Phys 2018; 19:234-243. [PMID: 30288917 PMCID: PMC6236844 DOI: 10.1002/acm2.12468] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/21/2018] [Revised: 08/25/2018] [Accepted: 09/09/2018] [Indexed: 11/29/2022] Open
Abstract
Purpose The aim of this study was to evaluate the utility of merged balanced steady‐state free precession (bSSFP) magnetic resonance cisternography images. Materials and Methods Twenty ears of 10 healthy volunteers (six men, four women; mean age ± standard deviation, 26.7 ± 1.6 yr) and 10 patients (two men, eight women; mean age, 46.3 ± 10.9 yr) with neoplasm around the sella turcica were included. Two different devices (A and B) were used to confirm the versatility of our method for MR devices with different local magnetic field homogeneity. Images with different central frequencies (±10, ±20, ±30, ±40, and ±50 Hz) were merged with the maximum magnitude of corresponding pixels from the images acquired using both devices. Two neuroradiologists visually graded the image quality of 11 sites in the inner ear and three sites around the sella turcica (scale: 0–2) and compared the quality with that of the corresponding basic image (0 Hz). Results The image quality was better in merged images of the vestibule, superior semicircular canal (SCC), posterior SCC, and horizontal SCC (P = 0.005 to 0.020 mainly at ±40 and ±50 Hz on devices A and B), as well as in merged images of the sella turcica and right cavernous sinus (±50 Hz, P = 0.003 and 0.020 on device B, respectively), than it was in the corresponding basic images. Conclusions The maximum magnitude merging of images with different central frequencies makes it possible to reduce banding artifacts on bSSFP images without the need for special pulse sequences and image processing programs.
Collapse
Affiliation(s)
- Koji Matsumoto
- Department of Radiology, Chiba University Hospital, Chiba, Japan.,Division of Health Sciences, Graduate School of Medical Sciences, Kanazawa University, Kanazawa, Ishikawa, Japan
| | - Hajime Yokota
- Diagnostic Radiology and Radiation Oncology, Graduate School of Medicine, Chiba University, Chiba, Japan
| | - Hiroki Mukai
- Diagnostic Radiology and Radiation Oncology, Graduate School of Medicine, Chiba University, Chiba, Japan
| | - Yoshitada Masuda
- Department of Radiology, Chiba University Hospital, Chiba, Japan
| | - Takashi Uno
- Diagnostic Radiology and Radiation Oncology, Graduate School of Medicine, Chiba University, Chiba, Japan
| | - Tosiaki Miyati
- Division of Health Sciences, Graduate School of Medical Sciences, Kanazawa University, Kanazawa, Ishikawa, Japan
| |
Collapse
|
10
|
Kim J, Seo H, So S, Park H. A multicontrast imaging method using steady-state free precession with alternating RF flip angles. Magn Reson Med 2018; 80:1341-1351. [DOI: 10.1002/mrm.27342] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/30/2018] [Revised: 03/20/2018] [Accepted: 04/12/2018] [Indexed: 11/08/2022]
Affiliation(s)
- Joonsoo Kim
- Department of Electrical Engineering; Korea Advanced Institute of Science and Technology; Daejeon Republic of Korea
| | - Hyunseok Seo
- Department of Electrical Engineering; Korea Advanced Institute of Science and Technology; Daejeon Republic of Korea
| | - Seohee So
- Department of Electrical Engineering; Korea Advanced Institute of Science and Technology; Daejeon Republic of Korea
| | - HyunWook Park
- Department of Electrical Engineering; Korea Advanced Institute of Science and Technology; Daejeon Republic of Korea
| |
Collapse
|
11
|
Biyik E, Ilicak E, Çukur T. Reconstruction by calibration over tensors for multi‐coil multi‐acquisition balanced SSFP imaging. Magn Reson Med 2017; 79:2542-2554. [DOI: 10.1002/mrm.26902] [Citation(s) in RCA: 12] [Impact Index Per Article: 1.7] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/30/2017] [Revised: 07/31/2017] [Accepted: 08/15/2017] [Indexed: 01/27/2023]
Affiliation(s)
- Erdem Biyik
- Department of Electrical and Electronics EngineeringBilkent UniversityAnkara Turkey
- National Magnetic Resonance Research Center (UMRAM), Bilkent UniversityAnkara Turkey
| | - Efe Ilicak
- Department of Electrical and Electronics EngineeringBilkent UniversityAnkara Turkey
- National Magnetic Resonance Research Center (UMRAM), Bilkent UniversityAnkara Turkey
| | - Tolga Çukur
- Department of Electrical and Electronics EngineeringBilkent UniversityAnkara Turkey
- National Magnetic Resonance Research Center (UMRAM), Bilkent UniversityAnkara Turkey
- Neuroscience ProgramSabuncu Brain Research Center, Bilkent UniversityAnkara Turkey
| |
Collapse
|
12
|
Hilbert T, Nguyen D, Thiran J, Krueger G, Kober T, Bieri O. True constructive interference in the steady state (trueCISS). Magn Reson Med 2017; 79:1901-1910. [DOI: 10.1002/mrm.26836] [Citation(s) in RCA: 6] [Impact Index Per Article: 0.9] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/09/2017] [Revised: 06/01/2017] [Accepted: 06/22/2017] [Indexed: 11/11/2022]
Affiliation(s)
- Tom Hilbert
- Advanced Clinical Imaging Technology (HC CEMEA SUI DI PI), Siemens Healthcare AGLausanne Switzerland
- LTS5, École Polytechnique Fédérale de LausanneLausanne Switzerland
- Department of RadiologyUniversity Hospital (CHUV)Lausanne Switzerland
| | - Damien Nguyen
- Division of Radiological PhysicsDepartment of Radiology, University Hospital Basel, University of BaselBasel Switzerland
- Department of Biomedical EngineeringUniversity of BaselBasel Switzerland
| | - Jean‐Philippe Thiran
- LTS5, École Polytechnique Fédérale de LausanneLausanne Switzerland
- Department of RadiologyUniversity Hospital (CHUV)Lausanne Switzerland
| | - Gunnar Krueger
- LTS5, École Polytechnique Fédérale de LausanneLausanne Switzerland
- Department of RadiologyUniversity Hospital (CHUV)Lausanne Switzerland
- Siemens Medical Solutions USABoston Massachusetts USA
| | - Tobias Kober
- Advanced Clinical Imaging Technology (HC CEMEA SUI DI PI), Siemens Healthcare AGLausanne Switzerland
- LTS5, École Polytechnique Fédérale de LausanneLausanne Switzerland
- Department of RadiologyUniversity Hospital (CHUV)Lausanne Switzerland
| | - Oliver Bieri
- Division of Radiological PhysicsDepartment of Radiology, University Hospital Basel, University of BaselBasel Switzerland
- Department of Biomedical EngineeringUniversity of BaselBasel Switzerland
| |
Collapse
|
13
|
Kim KH, Park SH. Artificial neural network for suppression of banding artifacts in balanced steady-state free precession MRI. Magn Reson Imaging 2017; 37:139-146. [DOI: 10.1016/j.mri.2016.11.020] [Citation(s) in RCA: 16] [Impact Index Per Article: 2.3] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/24/2016] [Accepted: 11/25/2016] [Indexed: 11/29/2022]
|
14
|
Ilicak E, Senel LK, Biyik E, Çukur T. Profile-encoding reconstruction for multiple-acquisition balanced steady-state free precession imaging. Magn Reson Med 2016; 78:1316-1329. [DOI: 10.1002/mrm.26507] [Citation(s) in RCA: 14] [Impact Index Per Article: 1.8] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/08/2016] [Revised: 09/02/2016] [Accepted: 09/21/2016] [Indexed: 11/12/2022]
Affiliation(s)
- Efe Ilicak
- Department of Electrical and Electronics Engineering; Bilkent University; Ankara Turkey
- National Magnetic Resonance Research Center (UMRAM); Bilkent University; Ankara Turkey
| | - Lutfi Kerem Senel
- Department of Electrical and Electronics Engineering; Bilkent University; Ankara Turkey
| | - Erdem Biyik
- Department of Electrical and Electronics Engineering; Bilkent University; Ankara Turkey
| | - Tolga Çukur
- Department of Electrical and Electronics Engineering; Bilkent University; Ankara Turkey
- National Magnetic Resonance Research Center (UMRAM); Bilkent University; Ankara Turkey
- Neuroscience Program, Graduate School of Engineering and Science; Bilkent University; Ankara Turkey
| |
Collapse
|
15
|
Hoff MN, Andre JB, Xiang Q. Combined geometric and algebraic solutions for removal of bSSFP banding artifacts with performance comparisons. Magn Reson Med 2016; 77:644-654. [DOI: 10.1002/mrm.26150] [Citation(s) in RCA: 5] [Impact Index Per Article: 0.6] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/01/2015] [Revised: 12/22/2015] [Accepted: 01/14/2015] [Indexed: 12/12/2022]
Affiliation(s)
- Michael N. Hoff
- Department of RadiologyUniversity of WashingtonSeattle Washington USA
| | - Jalal B. Andre
- Department of RadiologyUniversity of WashingtonSeattle Washington USA
| | - Qing‐San Xiang
- Department of Physics & AstronomyUniversity of British ColumbiaVancouver BC Canada
- Department of RadiologyUniversity of British ColumbiaVancouver BC Canada
| |
Collapse
|
16
|
Çukur T. Spectrally selective imaging with wideband balanced steady-state free precession MRI. Magn Reson Med 2015; 75:1132-41. [PMID: 25846631 DOI: 10.1002/mrm.25700] [Citation(s) in RCA: 4] [Impact Index Per Article: 0.4] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/10/2014] [Revised: 01/26/2015] [Accepted: 02/25/2015] [Indexed: 11/10/2022]
Abstract
PURPOSE Unwanted, bright fat signals in balanced steady-state free precession sequences are commonly suppressed using spectral shaping. Here, a new spectral-shaping method is proposed to significantly improve the uniformity of stopband suppression without compromising the level of passband signals. METHODS The proposed method combines binomial-pattern excitation pulses with a wideband balanced steady-state free precession sequence kernel. It thereby increases the frequency separation between the centers of pass and stopbands by π radians, enabling improved water-fat contrast. Simulations were performed to find the optimal flip angles and subpulse spacing for the binomial pulses that maximize contrast and signal efficiency. RESULTS Comparisons with a conventional binomial balanced steady-state free precession sequence were performed in simulations as well as phantom and in vivo experiments at 1.5 T and 3 T. Enhanced fat suppression is demonstrated in vivo with an average improvement of 58% in blood-fat and 68% in muscle-fat contrast (P < 0.001, Wilcoxon signed-rank test). CONCLUSION The proposed binomial wideband balanced steady-state free precession method is a promising candidate for spectrally selective imaging with enhanced reliability against field inhomogeneities.
Collapse
Affiliation(s)
- Tolga Çukur
- Department of Electrical and Electronics Engineering, Bilkent University, Ankara, Turkey.,National Magnetic Resonance Research Center, Bilkent University, Ankara, Turkey
| |
Collapse
|
17
|
Cukur T. Accelerated phase-cycled SSFP imaging with compressed sensing. IEEE TRANSACTIONS ON MEDICAL IMAGING 2015; 34:107-115. [PMID: 25134078 DOI: 10.1109/tmi.2014.2346814] [Citation(s) in RCA: 19] [Impact Index Per Article: 2.1] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 06/03/2023]
Abstract
Balanced steady-state free precession (SSFP) imaging suffers from irrecoverable signal losses, known as banding artifacts, in regions of large B0 field inhomogeneity. A common solution is to acquire multiple phase-cycled images each with a different frequency sensitivity, such that the location of banding artifacts are shifted in space. These images are then combined to alleviate signal loss across the entire field-of-view. Although high levels of artifact suppression are viable using a large number of images, this is a time costly process that limits clinical utility. Here, we propose to accelerate individual acquisitions such that the overall scan time is equal to that of a single SSFP acquisition. Aliasing artifacts and noise are minimized by using a variable-density random sampling pattern in k-space, and by generating disjoint sampling patterns for separate acquisitions. A sparsity-enforcing method is then used for image reconstruction. Demonstrations on realistic brain phantom images, and in vivo brain and knee images are provided. In all cases, the proposed technique enables robust SSFP imaging in the presence of field inhomogeneities without prolonging scan times.
Collapse
|
18
|
Diwoky C, Liebmann D, Neumayer B, Reinisch A, Knoll F, Strunk D, Stollberger R. Positive contrast of SPIO-labeled cells by off-resonant reconstruction of 3D radial half-echo bSSFP. NMR IN BIOMEDICINE 2015; 28:79-88. [PMID: 25379657 DOI: 10.1002/nbm.3229] [Citation(s) in RCA: 6] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 04/14/2014] [Revised: 10/02/2014] [Accepted: 10/03/2014] [Indexed: 06/04/2023]
Abstract
This article describes a new acquisition and reconstruction concept for positive contrast imaging of cells labeled with superparamagnetic iron oxides (SPIOs). Overcoming the limitations of a negative contrast representation as gained with gradient echo and fully balanced steady state (bSSFP), the proposed method delivers a spatially localized contrast with high cellular sensitivity not accomplished by other positive contrast methods. Employing a 3D radial bSSFP pulse sequence with half-echo sampling, positive cellular contrast is gained by adding artificial global frequency offsets to each half-echo before image reconstruction. The new contrast regime is highlighted with numerical intravoxel simulations including the point-spread function for 3D half-echo acquisitions. Furthermore, the new method is validated on the basis of in vitro cell phantom measurements on a clinical MRI platform, where the measured contrast-to-noise ratio (CNR) of the new approach exceeds even the negative contrast of bSSFP. Finally, an in vivo proof of principle study based on a mouse model with a clear depiction of labeled cells within a subcutaneous cell islet containing a cell density as low as 7 cells/mm(3) is presented. The resultant isotropic images show robustness to motion and a high CNR, in addition to an enhanced specificity due to the positive contrast of SPIO-labeled cells.
Collapse
Affiliation(s)
- Clemens Diwoky
- Institute of Medical Engineering, Graz University of Technology, Graz, Austria; BioTechMed-Graz, Graz, Austria
| | | | | | | | | | | | | |
Collapse
|
19
|
Benkert T, Ehses P, Blaimer M, Jakob PM, Breuer FA. Dynamically phase-cycled radial balanced SSFP imaging for efficient banding removal. Magn Reson Med 2014; 73:182-94. [PMID: 24478187 DOI: 10.1002/mrm.25113] [Citation(s) in RCA: 23] [Impact Index Per Article: 2.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/13/2013] [Revised: 12/09/2013] [Accepted: 12/12/2013] [Indexed: 11/07/2022]
Abstract
PURPOSE Balanced steady-state free precession (bSSFP) imaging suffers from banding artifacts due to its inherent sensitivity to inhomogeneities in the main magnetic field. These artifacts can be removed by the acquisition of multiple images at different frequency offsets. However, conventional phase-cycling is hindered by a long scan time. The purpose of this work is to present a novel approach for efficient banding removal in bSSFP imaging. THEORY AND METHODS To this end, the phase-cycle during a single-shot radial acquisition of an image was dynamically changed. Thus, each projection is acquired with a different frequency offset. Using conventional radial gridding, an artifact-free image can be reconstructed out of this dataset. RESULTS The approach is validated at clinical field strength [3.0 Tesla (T)] as well as at ultrahigh field (9.4T). Robust elimination of banding artifacts was obtained for different imaging regions, including brain imaging at ultrahigh field with an in-plane resolution of 0.25 × 0.25 mm(2). Besides banding artifact-free imaging, the applicability of the proposed technique for fat-water separation is demonstrated. CONCLUSION Dynamically phase-cycled radial bSSFP has the potential for banding-free bSSFP imaging in a short scan time, in the presence of severe field inhomogeneities and at high resolution.
Collapse
Affiliation(s)
- Thomas Benkert
- Research Center Magnetic Resonance Bavaria (MRB), Würzburg, Germany
| | - Philipp Ehses
- Department of Biomedical Magnetic Resonance, University of Tübingen, Tübingen, Germany.,High-Field MR Center, Max Planck Institute for Biological Cybernetics, Tübingen, Germany
| | - Martin Blaimer
- Research Center Magnetic Resonance Bavaria (MRB), Würzburg, Germany
| | - Peter M Jakob
- Research Center Magnetic Resonance Bavaria (MRB), Würzburg, Germany.,Department of Experimental Physics 5, University of Würzburg, Würzburg, Germany
| | - Felix A Breuer
- Research Center Magnetic Resonance Bavaria (MRB), Würzburg, Germany
| |
Collapse
|
20
|
Rosas H, Kijowski R. Volumetric magnetic resonance imaging of the musculoskeletal system. Semin Roentgenol 2013; 48:140-7. [PMID: 23452461 DOI: 10.1053/j.ro.2012.11.007] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/11/2022]
Affiliation(s)
- Humberto Rosas
- Department of Radiology, Musculoskeletal Division, University of Wisconsin School of Medicine and Public Health, Madison, WI 53792-3252, USA.
| | | |
Collapse
|
21
|
Strickland CD, Kijowski R. Morphologic Imaging of Articular Cartilage. Magn Reson Imaging Clin N Am 2011; 19:229-48. [DOI: 10.1016/j.mric.2011.02.009] [Citation(s) in RCA: 13] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/18/2022]
|
22
|
Jung KJ. Synthesis methods of multiple phase-cycled SSFP images to reduce the band artifact and noise more reliably. Magn Reson Imaging 2010; 28:103-18. [DOI: 10.1016/j.mri.2009.05.045] [Citation(s) in RCA: 8] [Impact Index Per Article: 0.6] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/25/2009] [Revised: 05/19/2009] [Accepted: 05/19/2009] [Indexed: 10/20/2022]
|
23
|
Cukur T, Lee JH, Bangerter NK, Hargreaves BA, Nishimura DG. Non-contrast-enhanced flow-independent peripheral MR angiography with balanced SSFP. Magn Reson Med 2009; 61:1533-9. [PMID: 19365850 DOI: 10.1002/mrm.21921] [Citation(s) in RCA: 39] [Impact Index Per Article: 2.6] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/10/2022]
Abstract
Flow-independent angiography is a non-contrast-enhanced technique that can generate vessel contrast even with reduced blood flow in the lower extremities. A method is presented for producing these angiograms with magnetization-prepared balanced steady-state free precession (bSSFP). Because bSSFP yields bright fat signal, robust fat suppression is essential for detailed depiction of the vasculature. Therefore, several strategies have been investigated to improve the reliability of fat suppression within short scan times. Phase-sensitive SSFP can efficiently suppress fat; however, partial volume effects due to fat and water occupying the same voxel can lead to the loss of blood signal. In contrast, alternating repetition time (ATR) SSFP minimizes this loss; however, the level of suppression is compromised by field inhomogeneity. Finally, a new double-acquisition ATR-SSFP technique reduces this sensitivity to off-resonance. In vivo results indicate that the two ATR-based techniques provide more reliable contrast when partial volume effects are significant.
Collapse
Affiliation(s)
- Tolga Cukur
- Magnetic Resonance Systems Research Laboratory, Department of Electrical Engineering, Stanford University, Stanford, California, USA.
| | | | | | | | | |
Collapse
|
24
|
Moran CJ, Kelcz F, Jung Y, Brodsky EK, Fain SB, Block WF. Pilot study of improved lesion characterization in breast MRI using a 3D radial balanced SSFP technique with isotropic resolution and efficient fat-water separation. J Magn Reson Imaging 2009; 30:135-44. [PMID: 19557728 DOI: 10.1002/jmri.21807] [Citation(s) in RCA: 5] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/07/2023] Open
Abstract
PURPOSE To assess a 3D radial balanced steady-state free precession (SSFP) technique that provides submillimeter isotropic resolution and inherently registered fat and water image volumes in comparison to conventional T2-weighted RARE imaging for lesion characterization in breast magnetic resonance imaging (MRI). MATERIALS AND METHODS 3D projection SSFP (3DPR-SSFP) combines a dual half-echo radial k-space trajectory with a linear combination fat/water separation technique (linear combination SSFP). A pilot study was performed in 20 patients to assess fat suppression and depiction of lesion morphology using 3DPR-SSFP. For all patients fat suppression was measured for the 3DPR-SSFP image volumes and depiction of lesion morphology was compared against corresponding T2-weighted fast spin echo (FSE) datasets for 15 lesions in 11 patients. RESULTS The isotropic 0.63 mm resolution of the 3DPR-SSFP sequence demonstrated improved depiction of lesion morphology in comparison to FSE. The 3DPR-SSFP fat and water datasets were available in a 5-minute scan time while average fat suppression with 3DPR-SSFP was 71% across all 20 patients. CONCLUSION 3DPR-SSFP has the potential to improve the lesion characterization information available in breast MRI, particularly in comparison to conventional FSE. A larger study is warranted to quantify the effect of 3DPR-SSFP on specificity.
Collapse
Affiliation(s)
- Catherine J Moran
- Department of Medical Physics, University of Wisconsin, Madison, Wisconsin, USA.
| | | | | | | | | | | |
Collapse
|
25
|
Kijowski R, Blankenbaker DG, Klaers JL, Shinki K, De Smet AA, Block WF. Vastly Undersampled Isotropic Projection Steady-State Free Precession Imaging of the Knee: Diagnostic Performance Compared with Conventional MR. Radiology 2009; 251:185-94. [DOI: 10.1148/radiol.2511081133] [Citation(s) in RCA: 80] [Impact Index Per Article: 5.3] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/11/2022]
|
26
|
Cukur T, Lustig M, Nishimura DG. Multiple-profile homogeneous image combination: application to phase-cycled SSFP and multicoil imaging. Magn Reson Med 2009; 60:732-8. [PMID: 18727089 DOI: 10.1002/mrm.21720] [Citation(s) in RCA: 27] [Impact Index Per Article: 1.8] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/09/2022]
Abstract
Signal inhomogeneities in MRI often appear as multiplicative weightings due to various factors such as field-inhomogeneity dependencies for steady-state free precession (SSFP) imaging or receiver sensitivities for coil arrays. These signal inhomogeneities can be reduced by combining multiple data sets with different weights. A sum-of-squares combination is typically used due to its simplicity and near-optimal signal-to-noise ratio (SNR). However, this combination may lead to residual signal inhomogeneity. Alternatively, an optimal linear combination of the data can be performed if the weightings for individual data sets are estimated accurately. We propose a nonlinear combination to improve image-based estimates of the individual weightings. The signal homogeneity can be significantly increased without compromising SNR. The improved performance of the method is demonstrated for SSFP banding artifact reduction and multicoil (phased-array and parallel) image reconstructions.
Collapse
Affiliation(s)
- Tolga Cukur
- Department of Electrical Engineering, Magnetic Resonance Systems Research Laboratory, Stanford University, Stanford, California, USA.
| | | | | |
Collapse
|