1
|
Fouquet JP, Sikpa D, Lebel R, Sibgatulin R, Krämer M, Herrmann KH, Deistung A, Tremblay L, Reichenbach JR, Lepage M. Characterization of microparticles of iron oxide for magnetic resonance imaging. Magn Reson Imaging 2022; 92:67-81. [DOI: 10.1016/j.mri.2022.05.020] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/17/2021] [Revised: 03/07/2022] [Accepted: 05/24/2022] [Indexed: 11/27/2022]
|
2
|
Maggiora GD, Castillo-Passi C, Qiu W, Liu S, Milovic C, Sekino M, Tejos C, Uribe S, Irarrazaval P. DeepSPIO: Super Paramagnetic Iron Oxide Particle Quantification Using Deep Learning in Magnetic Resonance Imaging. IEEE TRANSACTIONS ON PATTERN ANALYSIS AND MACHINE INTELLIGENCE 2022; 44:143-153. [PMID: 32750834 DOI: 10.1109/tpami.2020.3012103] [Citation(s) in RCA: 6] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 06/11/2023]
Abstract
The susceptibility of super paramagnetic iron oxide (SPIO) particles makes them a useful contrast agent for different purposes in MRI. These particles are typically quantified with relaxometry or by measuring the inhomogeneities they produced. These methods rely on the phase, which is unreliable for high concentrations. We present in this study a novel Deep Learning method to quantify the SPIO concentration distribution. We acquired the data with a new sequence called View Line in which the field map information is encoded in the geometry of the image. The novelty of our network is that it uses residual blocks as the bottleneck and multiple decoders to improve the gradient flow in the network. Each decoder predicts a different part of the wavelet decomposition of the concentration map. This decomposition improves the estimation of the concentration, and also it accelerates the convergence of the model. We tested our SPIO concentration reconstruction technique with simulated images and data from actual scans from phantoms. The simulations were done using images from the IXI dataset, and the phantoms consisted of plastic cylinders containing agar with SPIO particles at different concentrations. In both experiments, the model was able to quantify the distribution accurately.
Collapse
|
3
|
Goodfellow F, Simchick GA, Mortensen LJ, Stice SL, Zhao Q. Tracking and Quantification of Magnetically Labeled Stem Cells using Magnetic Resonance Imaging. ADVANCED FUNCTIONAL MATERIALS 2016; 26:3899-3915. [PMID: 28751853 PMCID: PMC5526633 DOI: 10.1002/adfm.201504444] [Citation(s) in RCA: 26] [Impact Index Per Article: 2.9] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 05/14/2023]
Abstract
Stem cell based therapies have critical impacts on treatments and cures of diseases such as neurodegenerative or cardiovascular disease. In vivo tracking of stem cells labeled with magnetic contrast agents is of particular interest and importance as it allows for monitoring of the cells' bio-distribution, viability, and physiological responses. Herein, recent advances are introduced in tracking and quantification of super-paramagnetic iron oxide (SPIO) nanoparticles-labeled cells with magnetic resonance imaging, a noninvasive approach that can longitudinally monitor transplanted cells. This is followed by recent translational research on human stem cells that are dual-labeled with green fluorescence protein (GFP) and SPIO nanoparticles, then transplanted and tracked in a chicken embryo model. Cell labeling efficiency, viability, and cell differentiation are also presented.
Collapse
Affiliation(s)
| | - Gregory A Simchick
- Bioimaging Research Center, Regenerative Bioscience Center, and Department of Physics University of Georgia, Athens, GA. 30602, USA
| | | | | | - Qun Zhao
- Bioimaging Research Center, Regenerative Bioscience Center, and Department of Physics University of Georgia, Athens, GA. 30602, USA
| |
Collapse
|
4
|
Gharagouzloo CA, McMahon PN, Sridhar S. Quantitative contrast-enhanced MRI with superparamagnetic nanoparticles using ultrashort time-to-echo pulse sequences. Magn Reson Med 2015; 74:431-41. [PMID: 25168606 PMCID: PMC6691359 DOI: 10.1002/mrm.25426] [Citation(s) in RCA: 28] [Impact Index Per Article: 2.8] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/05/2014] [Revised: 07/09/2014] [Accepted: 08/02/2014] [Indexed: 11/12/2022]
Abstract
PURPOSE Conventional MRI using contrast agents is semiquantitative because it is inherently sensitive to extravoxular susceptibility artifacts, field inhomogeneity, partial voluming, perivascular effects, and motion/flow artifacts. Herein we demonstrate a quantitative contrast-enhanced MRI technique using ultrashort time-to-echo pulse sequences for measuring clinically relevant concentrations of ferumoxytol, a superparamagnetic iron oxide nanoparticle contrast agent with high sensitivity and precision in vitro and in vivo. METHODS The method achieves robust, reproducible results by using rapid signal acquisition at ultrashort time-to-echo (UTE) to produce positive contrast images with pure T1 weighting and little T2* decay. The spoiled gradient echo equation is used to transform UTE intensities directly into concentration using experimentally determined relaxivity constants and image acquisition parameters. RESULTS A multiparametric optimization of acquisition parameters revealed an optimal zone capable of producing high-fidelity measurements. Clinically relevant intravascular concentrations of ferumoxytol were measured longitudinally in mice with high sensitivity and precision (∼7.1% error). MRI measurements were independently validated by elemental iron analysis of sequential blood draws. Automated segmentation of ferumoxytol concentration yielded high quality three-dimensional images for visualization of perfusion. CONCLUSIONS This ability to longitudinally quantify blood pool CA concentration is unique to quantitative UTE contrast-enhanced (QUTE-CE) MRI and makes QUTE-CE MRI competitive with nuclear imaging.
Collapse
Affiliation(s)
- Codi Amir Gharagouzloo
- Nanomedicine Science and Technology Center, Northeastern University, Boston, Massachusetts, USA
- Department of Bioengineering, Northeastern University, Boston, Massachusetts, USA
| | - Patrick N. McMahon
- Nanomedicine Science and Technology Center, Northeastern University, Boston, Massachusetts, USA
- Department of Physics, Northeastern University, Boston, Massachusetts, USA
| | - Srinivas Sridhar
- Nanomedicine Science and Technology Center, Northeastern University, Boston, Massachusetts, USA
- Department of Bioengineering, Northeastern University, Boston, Massachusetts, USA
- Department of Physics, Northeastern University, Boston, Massachusetts, USA
| |
Collapse
|
5
|
Perlman O, Weitz IS, Azhari H. Copper oxide nanoparticles as contrast agents for MRI and ultrasound dual-modality imaging. Phys Med Biol 2015; 60:5767-83. [PMID: 26159685 DOI: 10.1088/0031-9155/60/15/5767] [Citation(s) in RCA: 47] [Impact Index Per Article: 4.7] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 02/06/2023]
Abstract
Multimodal medical imaging is gaining increased popularity in the clinic. This stems from the fact that data acquired from different physical phenomena may provide complementary information resulting in a more comprehensive picture of the pathological state. In this context, nano-sized contrast agents may augment the potential sensitivity of each imaging modality and allow targeted visualization of physiological points of interest (e.g. tumours). In this study, 7 nm copper oxide nanoparticles (CuO NPs) were synthesized and characterized. Then, in vitro and phantom specimens containing CuO NPs ranging from 2.4 to 320 μg · mL(-1) were scanned, using both 9.4 T MRI and through-transmission ultrasonic imaging. The results show that the CuO NPs induce shortening of the magnetic T1 relaxation time on the one hand, and increase the speed of sound and ultrasonic attenuation coefficient on the other. Moreover, these visible changes are NP concentration-dependent. The change in the physical properties resulted in a substantial increase in the contrast-to-noise ratio (3.4-6.8 in ultrasound and 1.2-19.3 in MRI). In conclusion, CuO NPs are excellent candidates for MRI-ultrasound dual imaging contrast agents. They offer radiation-free high spatial resolution scans by MRI, and cost-effective high temporal resolution scans by ultrasound.
Collapse
Affiliation(s)
- Or Perlman
- Department of Biomedical Engineering, Technion-Israel Institute of Technology, Technion City, Haifa, 3200003, Israel
| | | | | |
Collapse
|
6
|
Danhier P, Magat J, Levêque P, De Preter G, Porporato PE, Bouzin C, Jordan BF, Demeur G, Haufroid V, Feron O, Sonveaux P, Gallez B. In vivo visualization and ex vivo quantification of murine breast cancer cells in the mouse brain using MRI cell tracking and electron paramagnetic resonance. NMR IN BIOMEDICINE 2015; 28:367-375. [PMID: 25611487 DOI: 10.1002/nbm.3259] [Citation(s) in RCA: 7] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 05/07/2014] [Revised: 11/10/2014] [Accepted: 12/19/2014] [Indexed: 06/04/2023]
Abstract
Cell tracking could be useful to elucidate fundamental processes of cancer biology such as metastasis. The aim of this study was to visualize, using MRI, and to quantify, using electron paramagnetic resonance (EPR), the entrapment of murine breast cancer cells labeled with superparamagnetic iron oxide particles (SPIOs) in the mouse brain after intracardiac injection. For this purpose, luciferase-expressing murine 4 T1-luc breast cancer cells were labeled with fluorescent Molday ION Rhodamine B SPIOs. Following intracardiac injection, SPIO-labeled 4 T1-luc cells were imaged using multiple gradient-echo sequences. Ex vivo iron oxide quantification in the mouse brain was performed using EPR (9 GHz). The long-term fate of 4 T1-luc cells after injection was characterized using bioluminescence imaging (BLI), brain MRI and immunofluorescence. We observed hypointense spots due to SPIO-labeled cells in the mouse brain 4 h after injection on T2 *-weighted images. Histology studies showed that SPIO-labeled cancer cells were localized within blood vessels shortly after delivery. Ex vivo quantification of SPIOs showed that less than 1% of the injected cells were taken up by the mouse brain after injection. MRI experiments did not reveal the development of macrometastases in the mouse brain several days after injection, but immunofluorescence studies demonstrated that these cells found in the brain established micrometastases. Concerning the metastatic patterns of 4 T1-luc cells, an EPR biodistribution study demonstrated that SPIO-labeled 4 T1-luc cells were also entrapped in the lungs of mice after intracardiac injection. BLI performed 6 days after injection of 4 T1-luc cells showed that this cell line formed macrometastases in the lungs and in the bones. Conclusively, EPR and MRI were found to be complementary for cell tracking applications. MRI cell tracking at 11.7 T allowed sensitive detection of isolated SPIO-labeled cells in the mouse brain, whereas EPR allowed the assessment of the number of SPIO-labeled cells in organs shortly after injection.
Collapse
Affiliation(s)
- Pierre Danhier
- Louvain Drug Research Institute, Biomedical Magnetic Resonance Research Group, Université catholique de Louvain, Brussels, Belgium
| | | | | | | | | | | | | | | | | | | | | | | |
Collapse
|
7
|
A dual ligand targeted nanoprobe with high MRI sensitivity for diagnosis of breast cancer. CHINESE JOURNAL OF POLYMER SCIENCE 2014. [DOI: 10.1007/s10118-014-1399-8] [Citation(s) in RCA: 10] [Impact Index Per Article: 0.9] [Reference Citation Analysis] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 12/31/2022]
|
8
|
Deligianni X, Jirák D, Berková Z, Hájek M, Scheffler K, Bieri O. In vivo visualization of cells labeled with superparamagnetic iron oxides by a sub-millisecond gradient echo sequence. MAGNETIC RESONANCE MATERIALS IN PHYSICS BIOLOGY AND MEDICINE 2013; 27:329-37. [DOI: 10.1007/s10334-013-0422-3] [Citation(s) in RCA: 4] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Track Full Text] [Subscribe] [Scholar Register] [Received: 03/08/2013] [Revised: 10/30/2013] [Accepted: 11/07/2013] [Indexed: 10/26/2022]
|
9
|
Seven-tesla magnetic resonance imaging accurately quantifies intratumoral uptake of therapeutic nanoparticles in the McA rat model of hepatocellular carcinoma: preclinical study in a rodent model. Invest Radiol 2013; 49:87-92. [PMID: 24089022 DOI: 10.1097/rli.0b013e3182a7e1b7] [Citation(s) in RCA: 5] [Impact Index Per Article: 0.4] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/25/2022]
Abstract
OBJECTIVES After inducing McA tumors in Sprague-Dawley rats (McA-SD), the following hypotheses were tested: first, that hypervascular McA tumors grown in Sprague-Dawley rats provide a suitable platform to investigate drug delivery; and second, that high-field MRI can be used to measure intratumoral uptake of DOX-SPIOs. MATERIALS AND METHODS McA cells were implanted into the livers of 18 Sprague-Dawley rats. In successfully inoculated animals, 220-μL DOX-SPIOs were delivered to tumors via the intravenous or intra-arterial route. Pretreatment and posttreatment T2*-weighted images were obtained using 7-T MRI, and change in R2* value (ΔR2*) was obtained from mean signal intensities of tumors in these images. Tumor iron concentration ([Fe]), an indicator of DOX-SPIO uptake, was measured using mass spectroscopy. The primary outcome variable was the Pearson correlation between ΔR2* and [Fe]. RESULTS Tumors grew successfully in 13 of the 18 animals (72%). Mean (SD) maximum tumor diameter was 0.83 (0.25) cm. The results of phantom studies revealed a strong positive correlation between ΔR2* and [Fe], with r = 0.98 (P < 0.01). The results of in vivo drug uptake studies demonstrated a positive correlation between ΔR2* and [Fe], with r = 0.72 (P = 0.0004). CONCLUSIONS The McA tumors grown in the Sprague-Dawley rats demonstrated uptake of nanoparticle-based therapeutic agents. Magnetic resonance imaging quantification of intratumoral uptake strongly correlated with iron concentrations in pathological specimens, suggesting that MRI may be used to quantify uptake of iron-oxide nanotherapeutics.
Collapse
|
10
|
Visscher M, Pouw JJ, van Baarlen J, Klaase JM, Ten Haken B. Quantitative analysis of superparamagnetic contrast agent in sentinel lymph nodes using ex vivo vibrating sample magnetometry. IEEE Trans Biomed Eng 2013; 60:2594-602. [PMID: 23674409 DOI: 10.1109/tbme.2013.2261893] [Citation(s) in RCA: 14] [Impact Index Per Article: 1.2] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/10/2022]
Abstract
As the first step in developing a new clinical technique for the magnetic detection of colorectal sentinel lymph nodes (SLNs), a method is developed to measure the magnetic content in intact, formalin fixated lymph nodes using a vibrating sample magnetometer (VSM). A suspension of superparamagnetic nanoparticles is injected ex vivo around the tumor in the resected colon segments. A selection of three lymph nodes is excised from the region around the tumor and is separately measured in the VSM. The iron content in the lymph nodes is quantified from the magnetic moment curve using the Langevin model for superparamagnetism and a bimodal particle size distribution. Adverse, parasitic movements of the sample were successfully reduced by tight fixation of the soft tissue and using a small vibration amplitude. Iron content in the lymph nodes is detected with 0.5 μg accuracy and ranged from 1 to 51 μg. Histological staining confirmed iron presence. The current method of measuring intact biological tissue in a VSM is suitable to show the feasibility and merit of magnetic detection of SLNs in colorectal cancer. For clinical validation of magnetic SLN selection in colorectal cancer, a new magnetometer with high specificity for superparamagnetic nanoparticles is required.
Collapse
Affiliation(s)
- Martijn Visscher
- Neuro-Imaging Group, MIRA Institute for Biomedical Engineering and Technical Medicine, University of Twente, 7500 AE Enschede, The Netherlands.
| | | | | | | | | |
Collapse
|
11
|
Bakker CJG, de Leeuw H, Seevinck PR. Selective depiction of susceptibility transitions using Laplace-filtered phase maps. Magn Reson Imaging 2012; 30:601-9. [PMID: 22406615 DOI: 10.1016/j.mri.2011.12.023] [Citation(s) in RCA: 9] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/11/2011] [Accepted: 12/11/2011] [Indexed: 11/19/2022]
Abstract
In this work, we aim to demonstrate the ability of Laplace-filtered three-dimensional (3D) phase maps to selectively depict the susceptibility transitions in an object. To realize this goal, it is first shown that both the Laplace derivative of the z component of the static magnetic field in an object and the Laplacian of the corresponding phase distribution may be expected to be zero in regions of constant or linearly varying susceptibility and to be nonzero when there is an abrupt change in susceptibility, for instance, at a single point, a ridge, an interface, an edge or a boundary. Next, a method is presented by which the Laplace derivative of a 3D phase map can be directly extracted from the complex data, without the need for phase unwrapping or subtraction of a reference image. The validity of this approach and of the theory behind it is subsequently demonstrated by simulations and phantom experiments with exactly known susceptibility distributions. Finally, the potential of the Laplace derivative analysis is illustrated by simulations with a Shepp-Logan digital brain phantom and experiments with a gel phantom containing positive and negative focal susceptibility deviations.
Collapse
Affiliation(s)
- Chris J G Bakker
- Department of Radiology, University Medical Center Utrecht, Heidelberglaan 100, 3584CX Utrecht, the Netherlands.
| | | | | |
Collapse
|
12
|
|
13
|
Huang J, Zhong X, Wang L, Yang L, Mao H. Improving the magnetic resonance imaging contrast and detection methods with engineered magnetic nanoparticles. Theranostics 2012; 2:86-102. [PMID: 22272222 PMCID: PMC3263519 DOI: 10.7150/thno.4006] [Citation(s) in RCA: 132] [Impact Index Per Article: 10.2] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/23/2011] [Accepted: 01/05/2012] [Indexed: 12/25/2022] Open
Abstract
Engineering and functionalizing magnetic nanoparticles have been an area of the extensive research and development in the biomedical and nanomedicine fields. Because their biocompatibility and toxicity are well investigated and better understood, magnetic nanoparticles, especially iron oxide nanoparticles, are better suited materials as contrast agents for magnetic resonance imaging (MRI) and for image-directed delivery of therapeutics. Given tunable magnetic properties and various surface chemistries from the coating materials, most applications of engineered magnetic nanoparticles take advantages of their superb MRI contrast enhancing capability as well as surface functionalities. It has been found that MRI contrast enhancement by magnetic nanoparticles is highly dependent on the composition, size and surface properties as well as the degree of aggregation of the nanoparticles. Therefore, understanding the relationships between these intrinsic parameters and the relaxivities that contribute to MRI contrast can lead to establishing essential guidance that may direct the design of engineered magnetic nanoparticles for theranostics applications. On the other hand, new contrast mechanism and imaging strategy can be developed based on the novel properties of engineered magnetic nanoparticles. This review will focus on discussing the recent findings on some chemical and physical properties of engineered magnetic nanoparticles affecting the relaxivities as well as the impact on MRI contrast. Furthermore, MRI methods for imaging magnetic nanoparticles including several newly developed MRI approaches aiming at improving the detection and quantification of the engineered magnetic nanoparticles are described.
Collapse
|
14
|
Wang PC, Shan L. Essential Elements to Consider for MRI Cell Tracking Studies with Iron Oxide-based Labeling Agents. JOURNAL OF BASIC AND CLINICAL MEDICINE 2012; 1:1-6. [PMID: 24159426 PMCID: PMC3805053] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Subscribe] [Scholar Register] [Indexed: 06/02/2023]
Abstract
Personalized diagnosis and treatment with allogenic or autologous cells have been intensively investigated over the past decade. Despite the promising findings in preclinical studies, the clinical results to date have been largely disappointing. Some critical issues remain to be solved, such as how to monitor the migration, homing, survival, and function of the transplanted cells in vivo. In the past years, imaging techniques have been introduced to solve these issues based on a concept that cells can be transformed to a cellular imaging agent following labeling of the cells with an imaging agent. For this purpose, magnetic resonance imaging (MRI) is so far the first choice imaging modality and iron oxide-based nanoparticles are the most frequently applied labeling agents. However, most MRI cell tracking studies are currently still limited in in vivo visualization of the labeled cells, some critical elements for cell tracking studies are often incompletely characterized, which makes it difficult to validate and meta-analyze the data generated from different studies. Incomplete information on preclinical studies also slows the transition of the findings to clinical practice. A robust protocol of MRI cell tracking studies is apparently critical to deal with these issues. In this review, we first briefly discuss the limitations of MRI cell tracking based on iron oxide nanoparticles and then recommend a minimum set of essential elements that should be considered in MRI cell tracking studies at preclinical stage.
Collapse
Affiliation(s)
- Paul C. Wang
- Molecular Imaging Laboratory, Department of Radiology, Howard University, Washington DC
| | - Liang Shan
- Molecular Imaging and Contrast Agents Database, National Center for Biotechnology Information, National Library of Medicine, MD
| |
Collapse
|
15
|
Shichinohe H, Kuroda S, Kudo K, Ito M, Kawabori M, Miyamoto M, Nakanishi M, Terae S, Houkin K. Visualization of the Superparamagnetic Iron Oxide (SPIO)-Labeled Bone Marrow Stromal Cells Using a 3.0-T MRI—a Pilot Study for Clinical Testing of Neurotransplantation. Transl Stroke Res 2011; 3:99-106. [DOI: 10.1007/s12975-011-0138-5] [Citation(s) in RCA: 12] [Impact Index Per Article: 0.9] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/15/2011] [Revised: 11/28/2011] [Accepted: 11/29/2011] [Indexed: 01/19/2023]
|
16
|
Sigovan M, Hamoudeh M, Al Faraj A, Charpigny D, Fessi H, Canet-Soulas E. Positive contrast with therapeutic iron nanoparticles at 4.7 T. MAGNETIC RESONANCE MATERIALS IN PHYSICS BIOLOGY AND MEDICINE 2011; 24:259-65. [DOI: 10.1007/s10334-011-0258-7] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.1] [Reference Citation Analysis] [Track Full Text] [Subscribe] [Scholar Register] [Received: 10/26/2010] [Revised: 04/13/2011] [Accepted: 05/06/2011] [Indexed: 01/24/2023]
|