1
|
Rao Q, Li H, Zhou Q, Zhang M, Zhao X, Shi L, Xie J, Fan L, Han Y, Guo F, Liu S, Zhou X. Assessment of pulmonary physiological changes caused by aging, cigarette smoking, and COPD with hyperpolarized 129Xe magnetic resonance. Eur Radiol 2024:10.1007/s00330-024-10800-w. [PMID: 38748243 DOI: 10.1007/s00330-024-10800-w] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/14/2024] [Revised: 03/14/2024] [Accepted: 04/05/2024] [Indexed: 06/01/2024]
Abstract
OBJECTIVE To comprehensively assess the impact of aging, cigarette smoking, and chronic obstructive pulmonary disease (COPD) on pulmonary physiology using 129Xe MR. METHODS A total of 90 subjects were categorized into four groups, including healthy young (HY, n = 20), age-matched control (AMC, n = 20), asymptomatic smokers (AS, n = 28), and COPD patients (n = 22). 129Xe MR was utilized to obtain pulmonary physiological parameters, including ventilation defect percent (VDP), alveolar sleeve depth (h), apparent diffusion coefficient (ADC), total septal wall thickness (d), and ratio of xenon signal from red blood cells and interstitial tissue/plasma (RBC/TP). RESULTS Significant differences were found in the measured VDP (p = 0.035), h (p = 0.003), and RBC/TP (p = 0.003) between the HY and AMC groups. Compared with the AMC group, higher VDP (p = 0.020) and d (p = 0.048) were found in the AS group; higher VDP (p < 0.001), d (p < 0.001) and ADC (p < 0.001), and lower h (p < 0.001) and RBC/TP (p < 0.001) were found in the COPD group. Moreover, significant differences were also found in the measured VDP (p < 0.001), h (p < 0.001), ADC (p < 0.001), d (p = 0.008), and RBC/TP (p = 0.032) between the AS and COPD groups. CONCLUSION Our findings indicate that pulmonary structure and functional changes caused by aging, cigarette smoking, and COPD are various, and show a progressive deterioration with the accumulation of these risk factors, including cigarette smoking and COPD. CLINICAL RELEVANCE STATEMENT Pathophysiological changes can be difficult to comprehensively understand due to limitations in common techniques and multifactorial etiologies. 129Xe MRI can demonstrate structural and functional changes caused by several common factors and can be used to better understand patients' underlying pathology. KEY POINTS Standard techniques for assessing pathophysiological lung function changes, spirometry, and chest CT come with limitations. 129Xe MR demonstrated progressive deterioration with accumulation of the investigated risk factors, without these limitations. 129Xe MR can assess lung changes related to these risk factors to stage and evaluate the etiology of the disease.
Collapse
Affiliation(s)
- Qiuchen Rao
- Key Laboratory of Magnetic Resonance in Biological Systems, State Key Laboratory of Magnetic Resonance and Atomic and Molecular Physics, National Center for Magnetic Resonance in Wuhan, Wuhan Institute of Physics and Mathematics, Innovation Academy for Precision Measurement Science and Technology, Chinese Academy of Sciences-Wuhan National Laboratory for Optoelectronics, Huazhong University of Science and Technology, Wuhan, 430071, China
| | - Haidong Li
- Key Laboratory of Magnetic Resonance in Biological Systems, State Key Laboratory of Magnetic Resonance and Atomic and Molecular Physics, National Center for Magnetic Resonance in Wuhan, Wuhan Institute of Physics and Mathematics, Innovation Academy for Precision Measurement Science and Technology, Chinese Academy of Sciences-Wuhan National Laboratory for Optoelectronics, Huazhong University of Science and Technology, Wuhan, 430071, China
- University of Chinese Academy of Sciences, Beijing, 100049, China
| | - Qian Zhou
- Key Laboratory of Magnetic Resonance in Biological Systems, State Key Laboratory of Magnetic Resonance and Atomic and Molecular Physics, National Center for Magnetic Resonance in Wuhan, Wuhan Institute of Physics and Mathematics, Innovation Academy for Precision Measurement Science and Technology, Chinese Academy of Sciences-Wuhan National Laboratory for Optoelectronics, Huazhong University of Science and Technology, Wuhan, 430071, China
| | - Ming Zhang
- Key Laboratory of Magnetic Resonance in Biological Systems, State Key Laboratory of Magnetic Resonance and Atomic and Molecular Physics, National Center for Magnetic Resonance in Wuhan, Wuhan Institute of Physics and Mathematics, Innovation Academy for Precision Measurement Science and Technology, Chinese Academy of Sciences-Wuhan National Laboratory for Optoelectronics, Huazhong University of Science and Technology, Wuhan, 430071, China
- University of Chinese Academy of Sciences, Beijing, 100049, China
| | - Xiuchao Zhao
- Key Laboratory of Magnetic Resonance in Biological Systems, State Key Laboratory of Magnetic Resonance and Atomic and Molecular Physics, National Center for Magnetic Resonance in Wuhan, Wuhan Institute of Physics and Mathematics, Innovation Academy for Precision Measurement Science and Technology, Chinese Academy of Sciences-Wuhan National Laboratory for Optoelectronics, Huazhong University of Science and Technology, Wuhan, 430071, China
- University of Chinese Academy of Sciences, Beijing, 100049, China
| | - Lei Shi
- Key Laboratory of Magnetic Resonance in Biological Systems, State Key Laboratory of Magnetic Resonance and Atomic and Molecular Physics, National Center for Magnetic Resonance in Wuhan, Wuhan Institute of Physics and Mathematics, Innovation Academy for Precision Measurement Science and Technology, Chinese Academy of Sciences-Wuhan National Laboratory for Optoelectronics, Huazhong University of Science and Technology, Wuhan, 430071, China
- University of Chinese Academy of Sciences, Beijing, 100049, China
| | - Junshuai Xie
- Key Laboratory of Magnetic Resonance in Biological Systems, State Key Laboratory of Magnetic Resonance and Atomic and Molecular Physics, National Center for Magnetic Resonance in Wuhan, Wuhan Institute of Physics and Mathematics, Innovation Academy for Precision Measurement Science and Technology, Chinese Academy of Sciences-Wuhan National Laboratory for Optoelectronics, Huazhong University of Science and Technology, Wuhan, 430071, China
- University of Chinese Academy of Sciences, Beijing, 100049, China
| | - Li Fan
- Department of Radiology, Changzheng Hospital of the Second Military Medical University, Shanghai, 200003, China
| | - Yeqing Han
- Key Laboratory of Magnetic Resonance in Biological Systems, State Key Laboratory of Magnetic Resonance and Atomic and Molecular Physics, National Center for Magnetic Resonance in Wuhan, Wuhan Institute of Physics and Mathematics, Innovation Academy for Precision Measurement Science and Technology, Chinese Academy of Sciences-Wuhan National Laboratory for Optoelectronics, Huazhong University of Science and Technology, Wuhan, 430071, China
- University of Chinese Academy of Sciences, Beijing, 100049, China
| | - Fumin Guo
- Key Laboratory of Magnetic Resonance in Biological Systems, State Key Laboratory of Magnetic Resonance and Atomic and Molecular Physics, National Center for Magnetic Resonance in Wuhan, Wuhan Institute of Physics and Mathematics, Innovation Academy for Precision Measurement Science and Technology, Chinese Academy of Sciences-Wuhan National Laboratory for Optoelectronics, Huazhong University of Science and Technology, Wuhan, 430071, China
| | - Shiyuan Liu
- Department of Radiology, Changzheng Hospital of the Second Military Medical University, Shanghai, 200003, China
| | - Xin Zhou
- Key Laboratory of Magnetic Resonance in Biological Systems, State Key Laboratory of Magnetic Resonance and Atomic and Molecular Physics, National Center for Magnetic Resonance in Wuhan, Wuhan Institute of Physics and Mathematics, Innovation Academy for Precision Measurement Science and Technology, Chinese Academy of Sciences-Wuhan National Laboratory for Optoelectronics, Huazhong University of Science and Technology, Wuhan, 430071, China.
- University of Chinese Academy of Sciences, Beijing, 100049, China.
- School of Biomedical Engineering, Hainan University, Haikou, 570228, China.
| |
Collapse
|
2
|
Hsia CCW, Bates JHT, Driehuys B, Fain SB, Goldin JG, Hoffman EA, Hogg JC, Levin DL, Lynch DA, Ochs M, Parraga G, Prisk GK, Smith BM, Tawhai M, Vidal Melo MF, Woods JC, Hopkins SR. Quantitative Imaging Metrics for the Assessment of Pulmonary Pathophysiology: An Official American Thoracic Society and Fleischner Society Joint Workshop Report. Ann Am Thorac Soc 2023; 20:161-195. [PMID: 36723475 PMCID: PMC9989862 DOI: 10.1513/annalsats.202211-915st] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 02/02/2023] Open
Abstract
Multiple thoracic imaging modalities have been developed to link structure to function in the diagnosis and monitoring of lung disease. Volumetric computed tomography (CT) renders three-dimensional maps of lung structures and may be combined with positron emission tomography (PET) to obtain dynamic physiological data. Magnetic resonance imaging (MRI) using ultrashort-echo time (UTE) sequences has improved signal detection from lung parenchyma; contrast agents are used to deduce airway function, ventilation-perfusion-diffusion, and mechanics. Proton MRI can measure regional ventilation-perfusion ratio. Quantitative imaging (QI)-derived endpoints have been developed to identify structure-function phenotypes, including air-blood-tissue volume partition, bronchovascular remodeling, emphysema, fibrosis, and textural patterns indicating architectural alteration. Coregistered landmarks on paired images obtained at different lung volumes are used to infer airway caliber, air trapping, gas and blood transport, compliance, and deformation. This document summarizes fundamental "good practice" stereological principles in QI study design and analysis; evaluates technical capabilities and limitations of common imaging modalities; and assesses major QI endpoints regarding underlying assumptions and limitations, ability to detect and stratify heterogeneous, overlapping pathophysiology, and monitor disease progression and therapeutic response, correlated with and complementary to, functional indices. The goal is to promote unbiased quantification and interpretation of in vivo imaging data, compare metrics obtained using different QI modalities to ensure accurate and reproducible metric derivation, and avoid misrepresentation of inferred physiological processes. The role of imaging-based computational modeling in advancing these goals is emphasized. Fundamental principles outlined herein are critical for all forms of QI irrespective of acquisition modality or disease entity.
Collapse
|
3
|
Kooner HK, McIntosh MJ, Desaigoudar V, Rayment JH, Eddy RL, Driehuys B, Parraga G. Pulmonary functional MRI: Detecting the structure-function pathologies that drive asthma symptoms and quality of life. Respirology 2022; 27:114-133. [PMID: 35008127 PMCID: PMC10025897 DOI: 10.1111/resp.14197] [Citation(s) in RCA: 3] [Impact Index Per Article: 1.5] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/21/2021] [Revised: 11/09/2021] [Accepted: 12/12/2021] [Indexed: 12/21/2022]
Abstract
Pulmonary functional MRI (PfMRI) using inhaled hyperpolarized, radiation-free gases (such as 3 He and 129 Xe) provides a way to directly visualize inhaled gas distribution and ventilation defects (or ventilation heterogeneity) in real time with high spatial (~mm3 ) resolution. Both gases enable quantitative measurement of terminal airway morphology, while 129 Xe uniquely enables imaging the transfer of inhaled gas across the alveolar-capillary tissue barrier to the red blood cells. In patients with asthma, PfMRI abnormalities have been shown to reflect airway smooth muscle dysfunction, airway inflammation and remodelling, luminal occlusions and airway pruning. The method is rapid (8-15 s), cost-effective (~$300/scan) and very well tolerated in patients, even in those who are very young or very ill, because unlike computed tomography (CT), positron emission tomography and single-photon emission CT, there is no ionizing radiation and the examination takes only a few seconds. However, PfMRI is not without limitations, which include the requirement of complex image analysis, specialized equipment and additional training and quality control. We provide an overview of the three main applications of hyperpolarized noble gas MRI in asthma research including: (1) inhaled gas distribution or ventilation imaging, (2) alveolar microstructure and finally (3) gas transfer into the alveolar-capillary tissue space and from the tissue barrier into red blood cells in the pulmonary microvasculature. We highlight the evidence that supports a deeper understanding of the mechanisms of asthma worsening over time and the pathologies responsible for symptoms and disease control. We conclude with a summary of approaches that have the potential for integration into clinical workflows and that may be used to guide personalized treatment planning.
Collapse
Affiliation(s)
- Harkiran K Kooner
- Robarts Research Institute, Western University, London, Ontario, Canada
- Department of Medical Biophysics, Western University, London, Ontario, Canada
| | - Marrissa J McIntosh
- Robarts Research Institute, Western University, London, Ontario, Canada
- Department of Medical Biophysics, Western University, London, Ontario, Canada
| | - Vedanth Desaigoudar
- Robarts Research Institute, Western University, London, Ontario, Canada
- Department of Medical Biophysics, Western University, London, Ontario, Canada
| | - Jonathan H Rayment
- Department of Pediatrics, University of British Columbia, Vancouver, British Columbia, Canada
| | - Rachel L Eddy
- Centre of Heart Lung Innovation, Division of Respiratory Medicine, Department of Medicine, University of British Columbia, Vancouver, British Columbia, Canada
| | - Bastiaan Driehuys
- Center for In Vivo Microscopy, Duke University Medical Centre, Durham, North Carolina, USA
| | - Grace Parraga
- Robarts Research Institute, Western University, London, Ontario, Canada
- Department of Medical Biophysics, Western University, London, Ontario, Canada
- Division of Respirology, Department of Medicine, Western University, London, Ontario, Canada
- School of Biomedical Engineering, Western University, London, Ontario, Canada
| |
Collapse
|
4
|
Niedbalski PJ, Hall CS, Castro M, Eddy RL, Rayment JH, Svenningsen S, Parraga G, Zanette B, Santyr GE, Thomen RP, Stewart NJ, Collier GJ, Chan HF, Wild JM, Fain SB, Miller GW, Mata JF, Mugler JP, Driehuys B, Willmering MM, Cleveland ZI, Woods JC. Protocols for multi-site trials using hyperpolarized 129 Xe MRI for imaging of ventilation, alveolar-airspace size, and gas exchange: A position paper from the 129 Xe MRI clinical trials consortium. Magn Reson Med 2021; 86:2966-2986. [PMID: 34478584 DOI: 10.1002/mrm.28985] [Citation(s) in RCA: 8] [Impact Index Per Article: 2.7] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/14/2021] [Revised: 07/13/2021] [Accepted: 08/06/2021] [Indexed: 12/12/2022]
Abstract
Hyperpolarized (HP) 129 Xe MRI uniquely images pulmonary ventilation, gas exchange, and terminal airway morphology rapidly and safely, providing novel information not possible using conventional imaging modalities or pulmonary function tests. As such, there is mounting interest in expanding the use of biomarkers derived from HP 129 Xe MRI as outcome measures in multi-site clinical trials across a range of pulmonary disorders. Until recently, HP 129 Xe MRI techniques have been developed largely independently at a limited number of academic centers, without harmonizing acquisition strategies. To promote uniformity and adoption of HP 129 Xe MRI more widely in translational research, multi-site trials, and ultimately clinical practice, this position paper from the 129 Xe MRI Clinical Trials Consortium (https://cpir.cchmc.org/XeMRICTC) recommends standard protocols to harmonize methods for image acquisition in HP 129 Xe MRI. Recommendations are described for the most common HP gas MRI techniques-calibration, ventilation, alveolar-airspace size, and gas exchange-across MRI scanner manufacturers most used for this application. Moreover, recommendations are described for 129 Xe dose volumes and breath-hold standardization to further foster consistency of imaging studies. The intention is that sites with HP 129 Xe MRI capabilities can readily implement these methods to obtain consistent high-quality images that provide regional insight into lung structure and function. While this document represents consensus at a snapshot in time, a roadmap for technical developments is provided that will further increase image quality and efficiency. These standardized dosing and imaging protocols will facilitate the wider adoption of HP 129 Xe MRI for multi-site pulmonary research.
Collapse
Affiliation(s)
- Peter J Niedbalski
- Division of Pulmonary, Critical Care, and Sleep Medicine, University of Kansas Medical Center, Kansas City, Kansas, USA
| | - Chase S Hall
- Division of Pulmonary, Critical Care, and Sleep Medicine, University of Kansas Medical Center, Kansas City, Kansas, USA
| | - Mario Castro
- Division of Pulmonary, Critical Care, and Sleep Medicine, University of Kansas Medical Center, Kansas City, Kansas, USA
| | - Rachel L Eddy
- Centre for Heart Lung Innovation, St. Paul's Hospital, University of British Columbia, Vancouver, British Columbia, Canada.,Division of Respiratory Medicine, Department of Medicine, University of British Columbia, Vancouver, British Columbia, Canada
| | - Jonathan H Rayment
- Division of Respiratory Medicine, Department of Pediatrics, University of British Columbia, Vancouver, British Columbia, Canada
| | - Sarah Svenningsen
- Firestone Institute for Respiratory Health, St Joseph's Healthcare, McMaster University, Hamilton, Ontario, Canada.,Department of Medicine, Division of Respirology, McMaster University, Hamilton, Ontario, Canada
| | - Grace Parraga
- Robarts Research Institute, Western University, London, Ontario, Canada
| | - Brandon Zanette
- Translational Medicine Program, Hospital for Sick Children, Toronto, Ontario, Canada
| | - Giles E Santyr
- Translational Medicine Program, Hospital for Sick Children, Toronto, Ontario, Canada.,Department of Medical Biophysics, University of Toronto, Toronto, Ontario, Canada
| | - Robert P Thomen
- Departments of Radiology and Bioengineering, University of Missouri, Columbia, Missouri, USA
| | - Neil J Stewart
- POLARIS, Department of Infection, Immunity & Cardiovascular Disease, University of Sheffield, Sheffield, UK
| | - Guilhem J Collier
- POLARIS, Department of Infection, Immunity & Cardiovascular Disease, University of Sheffield, Sheffield, UK
| | - Ho-Fung Chan
- POLARIS, Department of Infection, Immunity & Cardiovascular Disease, University of Sheffield, Sheffield, UK
| | - Jim M Wild
- POLARIS, Department of Infection, Immunity & Cardiovascular Disease, University of Sheffield, Sheffield, UK
| | - Sean B Fain
- Departments of Medical Physics, Radiology, and Biomedical Engineering, University of Wisconsin, Madison, Wisconsin, USA
| | - G Wilson Miller
- Center for In-vivo Hyperpolarized Gas MR Imaging, Department of Radiology and Medical Imaging, University of Virginia, Charlottesville, Virginia, USA
| | - Jaime F Mata
- Center for In-vivo Hyperpolarized Gas MR Imaging, Department of Radiology and Medical Imaging, University of Virginia, Charlottesville, Virginia, USA
| | - John P Mugler
- Center for In-vivo Hyperpolarized Gas MR Imaging, Department of Radiology and Medical Imaging, University of Virginia, Charlottesville, Virginia, USA
| | - Bastiaan Driehuys
- Department of Radiology, Duke University Medical Center, Durham, North Carolina, USA
| | - Matthew M Willmering
- Center for Pulmonary Imaging Research, Cincinnati Children's Hospital Medical Center, Cincinnati, Ohio, USA
| | - Zackary I Cleveland
- Center for Pulmonary Imaging Research, Cincinnati Children's Hospital Medical Center, Cincinnati, Ohio, USA.,Departments of Pediatrics (Pulmonary Medicine) and Radiology, Cincinnati Children's Hospital Medical Center, Cincinnati, Ohio, USA
| | - Jason C Woods
- Center for Pulmonary Imaging Research, Cincinnati Children's Hospital Medical Center, Cincinnati, Ohio, USA.,Departments of Pediatrics (Pulmonary Medicine) and Radiology, Cincinnati Children's Hospital Medical Center, Cincinnati, Ohio, USA
| |
Collapse
|
5
|
Dougherty JM, Castillo E, Castillo R, Faught AM, Pepin M, Park SS, Beltran CJ, Guerrero T, Grills I, Vinogradskiy Y. Functional avoidance-based intensity modulated proton therapy with 4DCT derived ventilation imaging for lung cancer. J Appl Clin Med Phys 2021; 22:276-285. [PMID: 34159715 PMCID: PMC8292710 DOI: 10.1002/acm2.13323] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/03/2021] [Revised: 05/14/2021] [Accepted: 05/17/2021] [Indexed: 12/25/2022] Open
Abstract
The primary objective is to evaluate the potential dosimetric gains of performing functional avoidance‐based proton treatment planning using 4DCT derived ventilation imaging. 4DCT data of 31 patients from a prospective functional avoidance clinical trial were evaluated with intensity modulated proton therapy (IMPT) plans and compared with clinical volumetric modulated arc therapy (VMAT) plans. Dosimetric parameters were compared between standard and functional plans with IMPT and VMAT with one‐way analysis of variance and post hoc paired student t‐test. Normal Tissue Complication Probability (NTCP) models were employed to estimate the risk of two toxicity endpoints for healthy lung tissues. Dose degradation due to proton motion interplay effect was evaluated. Functional IMPT plans led to significant dose reduction to functional lung structures when compared with functional VMAT without significant dose increase to Organ at Risk (OAR) structures. When interplay effect is considered, no significant dose degradation was observed for the OARs or the clinical target volume (CTV) volumes for functional IMPT. Using fV20 as the dose metric and Grade 2+ pneumonitis as toxicity endpoint, there is a mean 5.7% reduction in Grade 2+ RP with the functional IMPT and as high as 26% in reduction for individual patient when compared to the standard IMPT planning. Functional IMPT was able to spare healthy lung tissue to avoid excess dose to normal structures while maintaining satisfying target coverage. NTCP calculation also shows that the risk of pulmonary complications can be further reduced with functional based IMPT.
Collapse
Affiliation(s)
| | - Edward Castillo
- Department of Computational and Applied Mathematics, Rice University, Houston, TX, USA.,Department of Radiation Oncology, Beaumont Health System, Royal Oak, MI, USA
| | - Richard Castillo
- Department of Radiation Oncology, Emory University, Atlanta, GA, USA
| | - Austin M Faught
- Department of Radiation Oncology, St. Jude Children's Research Hospital, Memphis, TN, USA
| | - Mark Pepin
- Department of Radiation Oncology, Mayo Clinic, Rochester, MN, USA
| | - Sean S Park
- Department of Radiation Oncology, Mayo Clinic, Rochester, MN, USA
| | - Chris J Beltran
- Department of Radiation Oncology, Mayo Clinic, Jacksonville, FL, USA
| | - Thomas Guerrero
- Department of Radiation Oncology, Beaumont Health System, Royal Oak, MI, USA
| | - Inga Grills
- Department of Radiation Oncology, Beaumont Health System, Royal Oak, MI, USA
| | - Yevgeniy Vinogradskiy
- Department of Radiation Oncology, University of Colorado School of Medicine, Aurora, CO, USA
| |
Collapse
|
6
|
Marshall H, Stewart NJ, Chan HF, Rao M, Norquay G, Wild JM. In vivo methods and applications of xenon-129 magnetic resonance. PROGRESS IN NUCLEAR MAGNETIC RESONANCE SPECTROSCOPY 2021; 122:42-62. [PMID: 33632417 PMCID: PMC7933823 DOI: 10.1016/j.pnmrs.2020.11.002] [Citation(s) in RCA: 16] [Impact Index Per Article: 5.3] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 07/07/2020] [Revised: 11/26/2020] [Accepted: 11/29/2020] [Indexed: 05/28/2023]
Abstract
Hyperpolarised gas lung MRI using xenon-129 can provide detailed 3D images of the ventilated lung airspaces, and can be applied to quantify lung microstructure and detailed aspects of lung function such as gas exchange. It is sensitive to functional and structural changes in early lung disease and can be used in longitudinal studies of disease progression and therapy response. The ability of 129Xe to dissolve into the blood stream and its chemical shift sensitivity to its local environment allow monitoring of gas exchange in the lungs, perfusion of the brain and kidneys, and blood oxygenation. This article reviews the methods and applications of in vivo129Xe MR in humans, with a focus on the physics of polarisation by optical pumping, radiofrequency coil and pulse sequence design, and the in vivo applications of 129Xe MRI and MRS to examine lung ventilation, microstructure and gas exchange, blood oxygenation, and perfusion of the brain and kidneys.
Collapse
Affiliation(s)
- Helen Marshall
- POLARIS, Imaging Sciences, Department of Infection, Immunity and Cardiovascular Disease, University of Sheffield, Sheffield, United Kingdom
| | - Neil J Stewart
- POLARIS, Imaging Sciences, Department of Infection, Immunity and Cardiovascular Disease, University of Sheffield, Sheffield, United Kingdom
| | - Ho-Fung Chan
- POLARIS, Imaging Sciences, Department of Infection, Immunity and Cardiovascular Disease, University of Sheffield, Sheffield, United Kingdom
| | - Madhwesha Rao
- POLARIS, Imaging Sciences, Department of Infection, Immunity and Cardiovascular Disease, University of Sheffield, Sheffield, United Kingdom
| | - Graham Norquay
- POLARIS, Imaging Sciences, Department of Infection, Immunity and Cardiovascular Disease, University of Sheffield, Sheffield, United Kingdom
| | - Jim M Wild
- POLARIS, Imaging Sciences, Department of Infection, Immunity and Cardiovascular Disease, University of Sheffield, Sheffield, United Kingdom.
| |
Collapse
|
7
|
Tafti S, Garrison WJ, Mugler JP, Shim YM, Altes TA, Mata JF, de Lange EE, Cates GD, Ropp AM, Wang C, Miller GW. Emphysema Index Based on Hyperpolarized 3He or 129Xe Diffusion MRI: Performance and Comparison with Quantitative CT and Pulmonary Function Tests. Radiology 2020; 297:201-210. [PMID: 32779976 DOI: 10.1148/radiol.2020192804] [Citation(s) in RCA: 19] [Impact Index Per Article: 4.8] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/19/2022]
Abstract
Background Apparent diffusion coefficient (ADC) maps of inhaled hyperpolarized gases have shown promise in the characterization of emphysema in patients with chronic obstructive pulmonary disease (COPD), yet an easily interpreted quantitative metric beyond mean and standard deviation has not been established. Purpose To introduce a quantitative framework with which to characterize emphysema burden based on hyperpolarized helium 3 (3He) and xenon 129 (129Xe) ADC maps and compare its diagnostic performance with CT-based emphysema metrics and pulmonary function tests (PFTs). Materials and Methods Twenty-seven patients with mild, moderate, or severe COPD and 13 age-matched healthy control subjects participated in this retrospective study. Participants underwent CT and multiple b value diffusion-weighted 3He and 129Xe MRI examinations and standard PFTs between August 2014 and November 2017. ADC-based emphysema index was computed separately for each gas and b value as the fraction of lung voxels with ADC values greater than in the healthy group 99th percentile. The resulting values were compared with quantitative CT results (relative lung area <-950 HU) as the reference standard. Diagnostic performance metrics included area under the receiver operating characteristic curve (AUC). Spearman rank correlations and Wilcoxon rank sum tests were performed between ADC-, CT-, and PFT-based metrics, and intraclass correlation was performed between repeated measurements. Results Thirty-six participants were evaluated (mean age, 60 years ± 6 [standard deviation]; 20 women). ADC-based emphysema index was highly repeatable (intraclass correlation coefficient > 0.99) and strongly correlated with quantitative CT (r = 0.86, P < .001 for 3He; r = 0.85, P < .001 for 129Xe) with high AUC (≥0.93; 95% confidence interval [CI]: 0.85, 1.00). ADC emphysema indices were also correlated with percentage of predicted diffusing capacity of lung for carbon monoxide (r = -0.81, P < .001 for 3He; r = -0.80, P < .001 for 129Xe) and percentage of predicted residual lung volume divided by total lung capacity (r = 0.65, P < .001 for 3He; r = 0.61, P < .001 for 129Xe). Conclusion Emphysema index based on hyperpolarized helium 3 or xenon 129 diffusion MRI provides a repeatable measure of emphysema burden, independent of gas or b value, with similar diagnostic performance as quantitative CT or pulmonary function metrics. © RSNA, 2020 Online supplemental material is available for this article. See also the editorial by Schiebler and Fain in this issue.
Collapse
Affiliation(s)
- Sina Tafti
- From the Departments of Physics (S.T., G.D.C.), Biomedical Engineering (W.J.G., J.P.M., G.W.M.), Radiology and Medical Imaging (J.P.M., J.F.M., E.E.d.L., A.M.R., G.W.M.), and Medicine (Y.M.S.), University of Virginia, Box 801339, Charlottesville, VA 22908; Department of Radiology, University of Missouri, Columbia, Mo (T.A.A.); and Department of Science and Engineering, University of Nottingham, Ningbo, China (C.W.)
| | - William J Garrison
- From the Departments of Physics (S.T., G.D.C.), Biomedical Engineering (W.J.G., J.P.M., G.W.M.), Radiology and Medical Imaging (J.P.M., J.F.M., E.E.d.L., A.M.R., G.W.M.), and Medicine (Y.M.S.), University of Virginia, Box 801339, Charlottesville, VA 22908; Department of Radiology, University of Missouri, Columbia, Mo (T.A.A.); and Department of Science and Engineering, University of Nottingham, Ningbo, China (C.W.)
| | - John P Mugler
- From the Departments of Physics (S.T., G.D.C.), Biomedical Engineering (W.J.G., J.P.M., G.W.M.), Radiology and Medical Imaging (J.P.M., J.F.M., E.E.d.L., A.M.R., G.W.M.), and Medicine (Y.M.S.), University of Virginia, Box 801339, Charlottesville, VA 22908; Department of Radiology, University of Missouri, Columbia, Mo (T.A.A.); and Department of Science and Engineering, University of Nottingham, Ningbo, China (C.W.)
| | - Y Michael Shim
- From the Departments of Physics (S.T., G.D.C.), Biomedical Engineering (W.J.G., J.P.M., G.W.M.), Radiology and Medical Imaging (J.P.M., J.F.M., E.E.d.L., A.M.R., G.W.M.), and Medicine (Y.M.S.), University of Virginia, Box 801339, Charlottesville, VA 22908; Department of Radiology, University of Missouri, Columbia, Mo (T.A.A.); and Department of Science and Engineering, University of Nottingham, Ningbo, China (C.W.)
| | - Talissa A Altes
- From the Departments of Physics (S.T., G.D.C.), Biomedical Engineering (W.J.G., J.P.M., G.W.M.), Radiology and Medical Imaging (J.P.M., J.F.M., E.E.d.L., A.M.R., G.W.M.), and Medicine (Y.M.S.), University of Virginia, Box 801339, Charlottesville, VA 22908; Department of Radiology, University of Missouri, Columbia, Mo (T.A.A.); and Department of Science and Engineering, University of Nottingham, Ningbo, China (C.W.)
| | - Jaime F Mata
- From the Departments of Physics (S.T., G.D.C.), Biomedical Engineering (W.J.G., J.P.M., G.W.M.), Radiology and Medical Imaging (J.P.M., J.F.M., E.E.d.L., A.M.R., G.W.M.), and Medicine (Y.M.S.), University of Virginia, Box 801339, Charlottesville, VA 22908; Department of Radiology, University of Missouri, Columbia, Mo (T.A.A.); and Department of Science and Engineering, University of Nottingham, Ningbo, China (C.W.)
| | - Eduard E de Lange
- From the Departments of Physics (S.T., G.D.C.), Biomedical Engineering (W.J.G., J.P.M., G.W.M.), Radiology and Medical Imaging (J.P.M., J.F.M., E.E.d.L., A.M.R., G.W.M.), and Medicine (Y.M.S.), University of Virginia, Box 801339, Charlottesville, VA 22908; Department of Radiology, University of Missouri, Columbia, Mo (T.A.A.); and Department of Science and Engineering, University of Nottingham, Ningbo, China (C.W.)
| | - Gordon D Cates
- From the Departments of Physics (S.T., G.D.C.), Biomedical Engineering (W.J.G., J.P.M., G.W.M.), Radiology and Medical Imaging (J.P.M., J.F.M., E.E.d.L., A.M.R., G.W.M.), and Medicine (Y.M.S.), University of Virginia, Box 801339, Charlottesville, VA 22908; Department of Radiology, University of Missouri, Columbia, Mo (T.A.A.); and Department of Science and Engineering, University of Nottingham, Ningbo, China (C.W.)
| | - Alan M Ropp
- From the Departments of Physics (S.T., G.D.C.), Biomedical Engineering (W.J.G., J.P.M., G.W.M.), Radiology and Medical Imaging (J.P.M., J.F.M., E.E.d.L., A.M.R., G.W.M.), and Medicine (Y.M.S.), University of Virginia, Box 801339, Charlottesville, VA 22908; Department of Radiology, University of Missouri, Columbia, Mo (T.A.A.); and Department of Science and Engineering, University of Nottingham, Ningbo, China (C.W.)
| | - Chengbo Wang
- From the Departments of Physics (S.T., G.D.C.), Biomedical Engineering (W.J.G., J.P.M., G.W.M.), Radiology and Medical Imaging (J.P.M., J.F.M., E.E.d.L., A.M.R., G.W.M.), and Medicine (Y.M.S.), University of Virginia, Box 801339, Charlottesville, VA 22908; Department of Radiology, University of Missouri, Columbia, Mo (T.A.A.); and Department of Science and Engineering, University of Nottingham, Ningbo, China (C.W.)
| | - G Wilson Miller
- From the Departments of Physics (S.T., G.D.C.), Biomedical Engineering (W.J.G., J.P.M., G.W.M.), Radiology and Medical Imaging (J.P.M., J.F.M., E.E.d.L., A.M.R., G.W.M.), and Medicine (Y.M.S.), University of Virginia, Box 801339, Charlottesville, VA 22908; Department of Radiology, University of Missouri, Columbia, Mo (T.A.A.); and Department of Science and Engineering, University of Nottingham, Ningbo, China (C.W.)
| |
Collapse
|
8
|
Higano NS, Thomen RP, Quirk JD, Huyck HL, Hahn AD, Fain SB, Pryhuber GS, Woods JC. Alveolar Airspace Size in Healthy and Diseased Infant Lungs Measured via Hyperpolarized 3He Gas Diffusion Magnetic Resonance Imaging. Neonatology 2020; 117:704-712. [PMID: 33176330 PMCID: PMC7878286 DOI: 10.1159/000511084] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 02/11/2020] [Accepted: 08/22/2020] [Indexed: 12/11/2022]
Abstract
BACKGROUND Alveolar development and lung parenchymal simplification are not well characterized in vivo in neonatal patients with respiratory morbidities, such as bronchopulmonary dysplasia (BPD). Hyperpolarized (HP) gas diffusion magnetic resonance imaging (MRI) is a sensitive, safe, nonionizing, and noninvasive biomarker for measuring airspace size in vivo but has not yet been implemented in young infants. OBJECTIVE This work quantified alveolar airspace size via HP gas diffusion MRI in healthy and diseased explanted infant lung specimens, with comparison to histological morphometry. METHODS Lung specimens from 8 infants were obtained: 7 healthy left upper lobes (0-16 months, post-autopsy) and 1 left lung with filamin-A mutation, closely representing BPD lung disease (11 months, post-transplantation). Specimens were imaged using HP 3He diffusion MRI to generate apparent diffusion coefficients (ADCs) as biomarkers of alveolar airspace size, with comparison to mean linear intercept (Lm) via quantitative histology. RESULTS Mean ADC and Lm were significantly increased throughout the diseased specimen (ADC = 0.26 ± 0.06 cm2/s, Lm = 587 ± 212 µm) compared with healthy specimens (ADC = 0.14 ± 0.03 cm2/s, Lm = 133 ± 37 µm; p < 1 × 10-7); increased values reflect enlarged airspaces. Mean ADCs in healthy specimens were significantly correlated to Lm (r = 0.69, p = 0.041). CONCLUSIONS HP gas diffusion MRI is sensitive to healthy and diseased regional alveolar airspace size in infant lungs, with good comparison to quantitative histology in ex vivo specimens. This work demonstrates the translational potential of gas MRI techniques for in vivo assessment of normal and abnormal alveolar development in neonates with pulmonary disease.
Collapse
Affiliation(s)
- Nara S Higano
- Division of Pulmonary Medicine and Department of Radiology, Center for Pulmonary Imaging Research, Cincinnati Children's Hospital, Cincinnati, Ohio, USA,
| | - Robert P Thomen
- Department of Radiology and Bioengineering, University of Missouri, Columbia, Missouri, USA
| | - James D Quirk
- Mallinckrodt Institute of Radiology, Washington University in St. Louis, St. Louis, Missouri, USA
| | - Heidie L Huyck
- Division of Neonatology, Department of Pediatrics, University of Rochester, Rochester, New York, USA
| | - Andrew D Hahn
- Department of Medical Physics, University of Wisconsin-Madison, Madison, Wisconsin, USA
| | - Sean B Fain
- Department of Medical Physics, University of Wisconsin-Madison, Madison, Wisconsin, USA.,Department of Radiology, University of Wisconsin-Madison, Madison, Wisconsin, USA.,Department of Biomedical Engineering, University of Wisconsin-Madison, Madison, Wisconsin, USA
| | - Gloria S Pryhuber
- Division of Neonatology, Department of Pediatrics, University of Rochester, Rochester, New York, USA
| | - Jason C Woods
- Division of Pulmonary Medicine and Department of Radiology, Center for Pulmonary Imaging Research, Cincinnati Children's Hospital, Cincinnati, Ohio, USA.,Department of Pediatrics, University of Cincinnati, Cincinnati, Ohio, USA
| |
Collapse
|
9
|
Zhang H, Xie J, Xiao S, Zhao X, Zhang M, Shi L, Wang K, Wu G, Sun X, Ye C, Zhou X. Lung morphometry using hyperpolarized
129
Xe multi‐
b
diffusion
MRI
with compressed sensing in healthy subjects and patients with
COPD. Med Phys 2018; 45:3097-3108. [DOI: 10.1002/mp.12944] [Citation(s) in RCA: 17] [Impact Index Per Article: 2.8] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/06/2017] [Revised: 04/18/2018] [Accepted: 04/19/2018] [Indexed: 12/11/2022] Open
Affiliation(s)
- Huiting Zhang
- School of Physics Huazhong University of Science and Technology Wuhan 430074China
- State Key Laboratory of Magnetic Resonance and Atomic and Molecular Physics National Center for Magnetic Resonance in Wuhan Wuhan Institute of Physics and Mathematics Chinese Academy of Sciences Wuhan 430071China
| | - Junshuai Xie
- State Key Laboratory of Magnetic Resonance and Atomic and Molecular Physics National Center for Magnetic Resonance in Wuhan Wuhan Institute of Physics and Mathematics Chinese Academy of Sciences Wuhan 430071China
| | - Sa Xiao
- State Key Laboratory of Magnetic Resonance and Atomic and Molecular Physics National Center for Magnetic Resonance in Wuhan Wuhan Institute of Physics and Mathematics Chinese Academy of Sciences Wuhan 430071China
| | - Xiuchao Zhao
- State Key Laboratory of Magnetic Resonance and Atomic and Molecular Physics National Center for Magnetic Resonance in Wuhan Wuhan Institute of Physics and Mathematics Chinese Academy of Sciences Wuhan 430071China
| | - Ming Zhang
- State Key Laboratory of Magnetic Resonance and Atomic and Molecular Physics National Center for Magnetic Resonance in Wuhan Wuhan Institute of Physics and Mathematics Chinese Academy of Sciences Wuhan 430071China
| | - Lei Shi
- State Key Laboratory of Magnetic Resonance and Atomic and Molecular Physics National Center for Magnetic Resonance in Wuhan Wuhan Institute of Physics and Mathematics Chinese Academy of Sciences Wuhan 430071China
| | - Ke Wang
- Department of Magnetic Resonance Imaging Zhongnan Hospital of Wuhan University Wuhan 430071 China
| | - Guangyao Wu
- Department of Magnetic Resonance Imaging Zhongnan Hospital of Wuhan University Wuhan 430071 China
| | - Xianping Sun
- State Key Laboratory of Magnetic Resonance and Atomic and Molecular Physics National Center for Magnetic Resonance in Wuhan Wuhan Institute of Physics and Mathematics Chinese Academy of Sciences Wuhan 430071China
| | - Chaohui Ye
- School of Physics Huazhong University of Science and Technology Wuhan 430074China
- State Key Laboratory of Magnetic Resonance and Atomic and Molecular Physics National Center for Magnetic Resonance in Wuhan Wuhan Institute of Physics and Mathematics Chinese Academy of Sciences Wuhan 430071China
| | - Xin Zhou
- State Key Laboratory of Magnetic Resonance and Atomic and Molecular Physics National Center for Magnetic Resonance in Wuhan Wuhan Institute of Physics and Mathematics Chinese Academy of Sciences Wuhan 430071China
| |
Collapse
|
10
|
Kern AL, Vogel-Claussen J. Hyperpolarized gas MRI in pulmonology. Br J Radiol 2018; 91:20170647. [PMID: 29271239 PMCID: PMC5965996 DOI: 10.1259/bjr.20170647] [Citation(s) in RCA: 30] [Impact Index Per Article: 5.0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/30/2017] [Revised: 12/12/2017] [Accepted: 12/08/2017] [Indexed: 01/20/2023] Open
Abstract
Lung diseases have a high prevalence amongst the world population and their early diagnosis has been pointed out to be key for successful treatment. However, there is still a lack of non-invasive examination methods with sensitivity to early, local deterioration of lung function. Proton-based lung MRI is particularly challenging due to short T2* times and low proton density within the lung tissue. Hyperpolarized gas MRI is aan emerging technology providing a richness of methodologies which overcome the aforementioned problems. Unlike proton-based MRI, lung MRI of hyperpolarized gases may rely on imaging of spins in the lung's gas spaces or inside the lung tissue and thereby add substantial value and diagnostic potential to lung MRI. This review article gives an introduction to the MR physics of hyperpolarized media and presents the current state of hyperpolarized gas MRI of 3Headvasd and 129Xe in pulmonology. Key applications, ranging from static and dynamic ventilation imaging as well as oxygen-pressure mapping to 129Xe dissolved-phase imaging and spectroscopy are presented. Hyperpolarized gas MRI is compared to alternative examination methods based on MRI and future directions of hyperpolarized gas MRI are discussed.
Collapse
|
11
|
Yablonskiy DA, Sukstanskii AL, Quirk JD. Diffusion lung imaging with hyperpolarized gas MRI. NMR IN BIOMEDICINE 2017; 30:10.1002/nbm.3448. [PMID: 26676342 PMCID: PMC4911335 DOI: 10.1002/nbm.3448] [Citation(s) in RCA: 17] [Impact Index Per Article: 2.4] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 07/30/2015] [Revised: 10/20/2015] [Accepted: 10/22/2015] [Indexed: 05/28/2023]
Abstract
Lung imaging using conventional 1 H MRI presents great challenges because of the low density of lung tissue, lung motion and very fast lung tissue transverse relaxation (typical T2 * is about 1-2 ms). MRI with hyperpolarized gases (3 He and 129 Xe) provides a valuable alternative because of the very strong signal originating from inhaled gas residing in the lung airspaces and relatively slow gas T2 * relaxation (typical T2 * is about 20-30 ms). However, in vivo human experiments should be performed very rapidly - usually during a single breath-hold. In this review, we describe the recent developments in diffusion lung MRI with hyperpolarized gases. We show that a combination of the results of modeling of gas diffusion in lung airspaces and diffusion measurements with variable diffusion-sensitizing gradients allows the extraction of quantitative information on the lung microstructure at the alveolar level. From an MRI scan of less than 15 s, this approach, called in vivo lung morphometry, allows the provision of quantitative values and spatial distributions of the same physiological parameters as measured by means of 'standard' invasive stereology (mean linear intercept, surface-to-volume ratio, density of alveoli, etc.). In addition, the approach makes it possible to evaluate some advanced Weibel parameters characterizing lung microstructure: average radii of alveolar sacs and ducts, as well as the depth of their alveolar sleeves. Such measurements, providing in vivo information on the integrity of pulmonary acinar airways and their changes in different diseases, are of great importance and interest to a broad range of physiologists and clinicians. We also discuss a new type of experiment based on the in vivo lung morphometry technique combined with quantitative computed tomography measurements, as well as with gradient echo MRI measurements of hyperpolarized gas transverse relaxation in the lung airspaces. Such experiments provide additional information on the blood vessel volume fraction, specific gas volume and length of the acinar airways, and allow the evaluation of lung parenchymal and non-parenchymal tissue. Copyright © 2015 John Wiley & Sons, Ltd.
Collapse
Affiliation(s)
| | | | - James D Quirk
- Department of Radiology, Washington University, St. Louis, MO, USA
| |
Collapse
|
12
|
Ouriadov A, Lessard E, Sheikh K, Parraga G. Pulmonary MRI morphometry modeling of airspace enlargement in chronic obstructive pulmonary disease and alpha-1 antitrypsin deficiency. Magn Reson Med 2017; 79:439-448. [PMID: 28198571 DOI: 10.1002/mrm.26642] [Citation(s) in RCA: 18] [Impact Index Per Article: 2.6] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/19/2016] [Revised: 01/23/2017] [Accepted: 01/24/2017] [Indexed: 12/23/2022]
Abstract
PURPOSE We generated lung morphometry measurements using single-breath diffusion-weighted MRI and three different acinar duct models in healthy participants and patients with emphysema stemming from chronic obstructive lung disease (COPD) and alpha-1 antitrypsin deficiency (AATD). METHODS Single-breath-inhaled 3 He MRI with five diffusion sensitizations (b-value = 0, 1.6, 3.2, 4.8, and 6.4 s/cm2 ) was used, and signal intensities were fit using a cylindrical and single-compartment acinar-duct model to estimate MRI-derived mean linear intercept (Lm ) and surface-to-volume ratio (S/V). A stretched exponential model was also developed to estimate the mean airway length and Lm . RESULTS We evaluated 42 participants, including 15 elderly never-smokers (69 ± 5 years), 12 ex-smokers without COPD (67 ± 11 years), 9 COPD ex-smokers (80 ± 6 years), and 6 AATD patients (59 ± 6 years). In the never- and ex-smokers, the diffusing capacity of the lung for carbon monoxide (DLCO ) and computed tomography relative area of less than -950 Hounsfield units (RA950 ) were normal, but these were abnormal in the COPD and AATD patients, which is reflective of emphysema. Although cylindrical and stretched-exponential-model estimates of Lm and S/V were not significantly different, the single-compartment-model estimates were significantly different (P < 0.05) for the never- and ex-smoker subgroups. All models estimated significantly worse Lm and S/V in the AATD and COPD subgroups compared with the never- and ex-smokers without emphysema. CONCLUSIONS Differences in airspace enlargement may be estimated using Lm and S/V, generated using MRI and a stretched-exponential or cylindrical model of the acinar ducts. Magn Reson Med 79:439-448, 2018. © 2017 International Society for Magnetic Resonance in Medicine.
Collapse
Affiliation(s)
- Alexei Ouriadov
- Robarts Research Institute, London, Canada.,Department of Medical Biophysics, the University of Western Ontario, London, Canada
| | - Eric Lessard
- Robarts Research Institute, London, Canada.,Department of Medical Biophysics, the University of Western Ontario, London, Canada
| | - Khadija Sheikh
- Robarts Research Institute, London, Canada.,Department of Medical Biophysics, the University of Western Ontario, London, Canada
| | - Grace Parraga
- Robarts Research Institute, London, Canada.,Department of Medical Biophysics, the University of Western Ontario, London, Canada
| | | |
Collapse
|
13
|
Ruan W, Zhong J, Guan Y, Xia Y, Zhao X, Han Y, Sun X, Liu S, Ye C, Zhou X. Detection of smoke-induced pulmonary lesions by hyperpolarized129Xe diffusion kurtosis imaging in rat models. Magn Reson Med 2016; 78:1891-1899. [DOI: 10.1002/mrm.26566] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.4] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/30/2016] [Revised: 11/03/2016] [Accepted: 11/09/2016] [Indexed: 12/20/2022]
Affiliation(s)
- Weiwei Ruan
- Key Laboratory of Magnetic Resonance in Biological Systems, State Key Laboratory of Magnetic Resonance and Atomic and Molecular Physics, National Center for Magnetic Resonance in Wuhan, Wuhan Institute of Physics and Mathematics, Chinese Academy of Sciences; Wuhan P. R. China
- University of Chinese Academy of Sciences; Beijing P. R. China
| | - Jianping Zhong
- Key Laboratory of Magnetic Resonance in Biological Systems, State Key Laboratory of Magnetic Resonance and Atomic and Molecular Physics, National Center for Magnetic Resonance in Wuhan, Wuhan Institute of Physics and Mathematics, Chinese Academy of Sciences; Wuhan P. R. China
| | - Yu Guan
- Department of Radiology; Changzheng Hospital of the Second Military Medical University; Shanghai China
| | - Yi Xia
- Department of Radiology; Changzheng Hospital of the Second Military Medical University; Shanghai China
| | - Xiuchao Zhao
- Key Laboratory of Magnetic Resonance in Biological Systems, State Key Laboratory of Magnetic Resonance and Atomic and Molecular Physics, National Center for Magnetic Resonance in Wuhan, Wuhan Institute of Physics and Mathematics, Chinese Academy of Sciences; Wuhan P. R. China
| | - Yeqing Han
- Key Laboratory of Magnetic Resonance in Biological Systems, State Key Laboratory of Magnetic Resonance and Atomic and Molecular Physics, National Center for Magnetic Resonance in Wuhan, Wuhan Institute of Physics and Mathematics, Chinese Academy of Sciences; Wuhan P. R. China
| | - Xianping Sun
- Key Laboratory of Magnetic Resonance in Biological Systems, State Key Laboratory of Magnetic Resonance and Atomic and Molecular Physics, National Center for Magnetic Resonance in Wuhan, Wuhan Institute of Physics and Mathematics, Chinese Academy of Sciences; Wuhan P. R. China
- University of Chinese Academy of Sciences; Beijing P. R. China
| | - Shiyuan Liu
- Department of Radiology; Changzheng Hospital of the Second Military Medical University; Shanghai China
| | - Chaohui Ye
- Key Laboratory of Magnetic Resonance in Biological Systems, State Key Laboratory of Magnetic Resonance and Atomic and Molecular Physics, National Center for Magnetic Resonance in Wuhan, Wuhan Institute of Physics and Mathematics, Chinese Academy of Sciences; Wuhan P. R. China
- University of Chinese Academy of Sciences; Beijing P. R. China
| | - Xin Zhou
- Key Laboratory of Magnetic Resonance in Biological Systems, State Key Laboratory of Magnetic Resonance and Atomic and Molecular Physics, National Center for Magnetic Resonance in Wuhan, Wuhan Institute of Physics and Mathematics, Chinese Academy of Sciences; Wuhan P. R. China
- University of Chinese Academy of Sciences; Beijing P. R. China
| |
Collapse
|
14
|
Walkup LL, Thomen RP, Akinyi T, Watters E, Ruppert K, Clancy JP, Woods JC, Cleveland ZI. Feasibility, tolerability and safety of pediatric hyperpolarized 129Xe magnetic resonance imaging in healthy volunteers and children with cystic fibrosis. Pediatr Radiol 2016; 46:1651-1662. [PMID: 27492388 PMCID: PMC5083137 DOI: 10.1007/s00247-016-3672-1] [Citation(s) in RCA: 66] [Impact Index Per Article: 8.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 01/25/2016] [Revised: 06/05/2016] [Accepted: 07/20/2016] [Indexed: 10/21/2022]
Abstract
BACKGROUND Hyperpolarized 129Xe is a promising contrast agent for MRI of pediatric lung function, but its safety and tolerability in children have not been rigorously assessed. OBJECTIVE To assess the feasibility, safety and tolerability of hyperpolarized 129Xe gas as an inhaled contrast agent for pediatric pulmonary MRI in healthy control subjects and in children with cystic fibrosis. MATERIALS AND METHODS Seventeen healthy control subjects (ages 6-15 years, 11 boys) and 11 children with cystic fibrosis (ages 8-16 years, 4 boys) underwent 129Xe MRI, receiving up to three doses of 129Xe gas prepared by either a commercially available or a homebuilt 129Xe polarizer. Subject heart rate and SpO2 were monitored for 2 min post inhalation and compared to resting baseline values. Adverse events were reported via follow-up phone call at days 1 and 30 (range ±7 days) post-MRI. RESULTS All children tolerated multiple doses of 129Xe, and no children withdrew from the study. Relative to baseline, most children who received a full dose of gas for imaging (10 of 12 controls and 8 of 11 children with cystic fibrosis) experienced a nadir in SpO2 (mean -6.0 ± standard deviation 7.2%, P≤0.001); however within 2 min post inhalation SpO2 values showed no significant difference from baseline (P=0.11). There was a slight elevation in heart rate (mean +6.6 ± 13.9 beats per minute [bpm], P=0.021), which returned from baseline within 2 min post inhalation (P=0.35). Brief side effects related to the anesthetic properties of xenon were mild and quickly resolved without intervention. No serious or severe adverse events were observed; in total, four minor adverse events (14.3%) were reported following 129Xe MRI, but all were deemed unrelated to the study. CONCLUSION The feasibility, safety and tolerability of 129Xe MRI has been assessed in a small group of children as young as 6 years. SpO2 changes were consistent with the expected physiological effects of a short anoxic breath-hold, and other mild side effects were consistent with the known anesthetic properties of xenon and with previous safety assessments of 129Xe MRI in adults. Hyperpolarized 129Xe is a safe and well-tolerated inhaled contrast agent for pulmonary MR imaging in healthy children and in children with cystic fibrosis who have mild to moderate lung disease.
Collapse
Affiliation(s)
- Laura L. Walkup
- Center for Pulmonary Imaging Research, Division of Pulmonary Medicine and Department of Radiology, Cincinnati Children’s Hospital Medical Center, 3333 Burnet Ave., MLC 5033, Cincinnati, OH 45229, USA
| | - Robert P. Thomen
- Center for Pulmonary Imaging Research, Division of Pulmonary Medicine and Department of Radiology, Cincinnati Children’s Hospital Medical Center, 3333 Burnet Ave., MLC 5033, Cincinnati, OH 45229, USA,Department of Physics, Washington University in St. Louis, St. Louis, MO, USA
| | - Teckla Akinyi
- Center for Pulmonary Imaging Research, Division of Pulmonary Medicine and Department of Radiology, Cincinnati Children’s Hospital Medical Center, 3333 Burnet Ave., MLC 5033, Cincinnati, OH 45229, USA,Biomedical Engineering Program, University of Cincinnati, Cincinnati, OH, USA
| | - Erin Watters
- Center for Pulmonary Imaging Research, Division of Pulmonary Medicine and Department of Radiology, Cincinnati Children’s Hospital Medical Center, 3333 Burnet Ave., MLC 5033, Cincinnati, OH 45229, USA
| | - Kai Ruppert
- Center for Pulmonary Imaging Research, Division of Pulmonary Medicine and Department of Radiology, Cincinnati Children’s Hospital Medical Center, 3333 Burnet Ave., MLC 5033, Cincinnati, OH 45229, USA
| | - John P. Clancy
- Division of Pulmonary Medicine, Cincinnati Children’s Hospital Medical Center, Cincinnati, OH, USA
| | - Jason C. Woods
- Center for Pulmonary Imaging Research, Division of Pulmonary Medicine and Department of Radiology, Cincinnati Children’s Hospital Medical Center, 3333 Burnet Ave., MLC 5033, Cincinnati, OH 45229, USA,Department of Physics, Washington University in St. Louis, St. Louis, MO, USA
| | - Zackary I. Cleveland
- Center for Pulmonary Imaging Research, Division of Pulmonary Medicine and Department of Radiology, Cincinnati Children’s Hospital Medical Center, 3333 Burnet Ave., MLC 5033, Cincinnati, OH 45229, USA,Biomedical Engineering Program, University of Cincinnati, Cincinnati, OH, USA
| |
Collapse
|
15
|
Ruan W, Zhong J, Wang K, Wu G, Han Y, Sun X, Ye C, Zhou X. Detection of the mild emphysema by quantification of lung respiratory airways with hyperpolarized xenon diffusion MRI. J Magn Reson Imaging 2016; 45:879-888. [PMID: 27472552 DOI: 10.1002/jmri.25408] [Citation(s) in RCA: 15] [Impact Index Per Article: 1.9] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/24/2016] [Accepted: 07/15/2016] [Indexed: 11/06/2022] Open
Abstract
PURPOSE To demonstrate the feasibility to quantify the lung respiratory airway in vivo with hyperpolarized xenon diffusion magnetic resonance imaging (MRI), which is able to detect mild emphysema in the rat model. MATERIALS AND METHODS The lung respiratory airways were quantified in vivo using hyperpolarized xenon diffusion MRI (7T) with eight b values (5, 10, 15, 20, 25, 30, 35, 40 s/cm2 ) in five control rats and five mild emphysematous rats, which were induced by elastase. The morphological results from histology were acquired and used for comparison. RESULTS The parameters DL (longitudinal diffusion coefficient), r (internal radius), h (alveolar sleeve depth), Lm (mean linear intercept), and S/V (surface area to lung volume ratio) derived from the hyperpolarized xenon diffusion MRI in the emphysematous group showed significant differences from those in the control group (P < 0.05). Additionally, these parameters correlated well with the Lm obtained by the traditional histological sections (Pearson's correlation coefficients >0.8). CONCLUSION The lung respiratory airways can be quantified by hyperpolarized xenon diffusion MRI, showing the potential for mild emphysema diagnosis. Also, the study suggested that the hyperpolarized xenon DL is more sensitive than DT (transverse diffusion coefficient) to detect mild emphysema. LEVEL OF EVIDENCE 1 J. Magn. Reson. Imaging 2017;45:879-888.
Collapse
Affiliation(s)
- Weiwei Ruan
- Key Laboratory of Magnetic Resonance in Biological Systems, State Key Laboratory of Magnetic Resonance and Atomic and Molecular Physics, National Center for Magnetic Resonance in Wuhan, Wuhan Institute of Physics and Mathematics, Chinese Academy of Sciences, Wuhan, P.R. China
| | - Jianping Zhong
- Key Laboratory of Magnetic Resonance in Biological Systems, State Key Laboratory of Magnetic Resonance and Atomic and Molecular Physics, National Center for Magnetic Resonance in Wuhan, Wuhan Institute of Physics and Mathematics, Chinese Academy of Sciences, Wuhan, P.R. China
| | - Ke Wang
- Department of Magnetic Resonance Imaging, Zhongnan Hospital of Wuhan University, Wuhan, P.R. China
| | - Guangyao Wu
- Department of Magnetic Resonance Imaging, Zhongnan Hospital of Wuhan University, Wuhan, P.R. China
| | - Yeqing Han
- Key Laboratory of Magnetic Resonance in Biological Systems, State Key Laboratory of Magnetic Resonance and Atomic and Molecular Physics, National Center for Magnetic Resonance in Wuhan, Wuhan Institute of Physics and Mathematics, Chinese Academy of Sciences, Wuhan, P.R. China
| | - Xianping Sun
- Key Laboratory of Magnetic Resonance in Biological Systems, State Key Laboratory of Magnetic Resonance and Atomic and Molecular Physics, National Center for Magnetic Resonance in Wuhan, Wuhan Institute of Physics and Mathematics, Chinese Academy of Sciences, Wuhan, P.R. China
| | - Chaohui Ye
- Key Laboratory of Magnetic Resonance in Biological Systems, State Key Laboratory of Magnetic Resonance and Atomic and Molecular Physics, National Center for Magnetic Resonance in Wuhan, Wuhan Institute of Physics and Mathematics, Chinese Academy of Sciences, Wuhan, P.R. China
| | - Xin Zhou
- Key Laboratory of Magnetic Resonance in Biological Systems, State Key Laboratory of Magnetic Resonance and Atomic and Molecular Physics, National Center for Magnetic Resonance in Wuhan, Wuhan Institute of Physics and Mathematics, Chinese Academy of Sciences, Wuhan, P.R. China
| |
Collapse
|
16
|
Kruger SJ, Nagle SK, Couch MJ, Ohno Y, Albert M, Fain SB. Functional imaging of the lungs with gas agents. J Magn Reson Imaging 2016; 43:295-315. [PMID: 26218920 PMCID: PMC4733870 DOI: 10.1002/jmri.25002] [Citation(s) in RCA: 77] [Impact Index Per Article: 9.6] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/02/2015] [Accepted: 06/26/2015] [Indexed: 12/22/2022] Open
Abstract
This review focuses on the state-of-the-art of the three major classes of gas contrast agents used in magnetic resonance imaging (MRI)-hyperpolarized (HP) gas, molecular oxygen, and fluorinated gas--and their application to clinical pulmonary research. During the past several years there has been accelerated development of pulmonary MRI. This has been driven in part by concerns regarding ionizing radiation using multidetector computed tomography (CT). However, MRI also offers capabilities for fast multispectral and functional imaging using gas agents that are not technically feasible with CT. Recent improvements in gradient performance and radial acquisition methods using ultrashort echo time (UTE) have contributed to advances in these functional pulmonary MRI techniques. The relative strengths and weaknesses of the main functional imaging methods and gas agents are compared and applications to measures of ventilation, diffusion, and gas exchange are presented. Functional lung MRI methods using these gas agents are improving our understanding of a wide range of chronic lung diseases, including chronic obstructive pulmonary disease, asthma, and cystic fibrosis in both adults and children.
Collapse
Affiliation(s)
- Stanley J. Kruger
- Department of Medical Physics, University of Wisconsin – Madison, WI, U.S.A
| | - Scott K. Nagle
- Department of Medical Physics, University of Wisconsin – Madison, WI, U.S.A
- Department of Radiology, University of Wisconsin – Madison, WI, U.S.A
- Department of Pediatrics, University of Wisconsin – Madison, WI, U.S.A
| | - Marcus J. Couch
- Thunder Bay Regional Research Institute, Thunder Bay, ON, Canada
- Biotechnology Program, Lakehead University, Thunder Bay, ON, Canada
| | - Yoshiharu Ohno
- Department of Radiology, Kobe University Graduate School of Medicine, Kobe, Japan
| | - Mitchell Albert
- Thunder Bay Regional Research Institute, Thunder Bay, ON, Canada
- Department of Chemistry, Lakehead University, Thunder Bay, ON, Canada
| | - Sean B. Fain
- Department of Medical Physics, University of Wisconsin – Madison, WI, U.S.A
- Department of Radiology, University of Wisconsin – Madison, WI, U.S.A
- Department of Biomedical Engineering, University of Wisconsin – Madison, WI, U.S.A
| |
Collapse
|
17
|
Abstract
Imaging has played a vital role in the clinical assessment of bronchopulmonary dysplasia (BPD) since its first recognition. In this review, how chest radiograph, computerized tomography (CT), nuclear medicine, and MRI have contributed to the understanding of BPD pathology and how emerging advancements in these methods, including low-dose and quantitative CT, sophisticated proton and hyperpolarized-gas MRI, influence the future of BPD imaging are discussed.
Collapse
Affiliation(s)
- Laura L Walkup
- Division of Pulmonary Medicine, Department of Radiology, Center for Pulmonary Imaging Research, Cincinnati Children's Hospital Medical Center, 3333 Burnet Avenue, MC 5033, Cincinnati, OH 42229, USA
| | - Jason C Woods
- Division of Pulmonary Medicine, Department of Radiology, Center for Pulmonary Imaging Research, Cincinnati Children's Hospital Medical Center, 3333 Burnet Avenue, MC 5033, Cincinnati, OH 42229, USA.
| |
Collapse
|
18
|
Quirk JD, Sukstanskii AL, Woods JC, Lutey BA, Conradi MS, Gierada DS, Yusen RD, Castro M, Yablonskiy DA. Experimental evidence of age-related adaptive changes in human acinar airways. J Appl Physiol (1985) 2015; 120:159-65. [PMID: 26542518 DOI: 10.1152/japplphysiol.00541.2015] [Citation(s) in RCA: 28] [Impact Index Per Article: 3.1] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/29/2015] [Accepted: 11/01/2015] [Indexed: 11/22/2022] Open
Abstract
The progressive decline of lung function with aging is associated with changes in lung structure at all levels, from conducting airways to acinar airways (alveolar ducts and sacs). While information on conducting airways is becoming available from computed tomography, in vivo information on the acinar airways is not conventionally available, even though acini occupy 95% of lung volume and serve as major gas exchange units of the lung. The objectives of this study are to measure morphometric parameters of lung acinar airways in living adult humans over a broad range of ages by using an innovative MRI-based technique, in vivo lung morphometry with hyperpolarized (3)He gas, and to determine the influence of age-related differences in acinar airway morphometry on lung function. Pulmonary function tests and MRI with hyperpolarized (3)He gas were performed on 24 healthy nonsmokers aged 19-71 years. The most significant age-related difference across this population was a 27% loss of alveolar depth, h, leading to a 46% increased acinar airway lumen radius, hence, decreased resistance to acinar air transport. Importantly, the data show a negative correlation between h and the pulmonary function measures forced expiratory volume in 1 s and forced vital capacity. In vivo lung morphometry provides unique information on age-related changes in lung microstructure and their influence on lung function. We hypothesize that the observed reduction of alveolar depth in subjects with advanced aging represents a remodeling process that might be a compensatory mechanism, without which the pulmonary functional decline due to other biological factors with advancing age would be significantly larger.
Collapse
Affiliation(s)
- James D Quirk
- Mallinckrodt Institute of Radiology, Washington University School of Medicine, St. Louis, Missouri
| | - Alexander L Sukstanskii
- Mallinckrodt Institute of Radiology, Washington University School of Medicine, St. Louis, Missouri
| | - Jason C Woods
- Center for Pulmonary Imaging Research, Cincinnati Children's Hospital Medical Center, Cincinnati, Ohio; Department of Physics, Washington University, St. Louis, Missouri
| | - Barbara A Lutey
- Department of Internal Medicine, Division of Medical Education, Washington University School of Medicine, St. Louis, Missouri; and
| | - Mark S Conradi
- Department of Physics, Washington University, St. Louis, Missouri
| | - David S Gierada
- Mallinckrodt Institute of Radiology, Washington University School of Medicine, St. Louis, Missouri
| | - Roger D Yusen
- Department of Internal Medicine, Division of Pulmonary and Critical Care Medicine, Washington University School of Medicine, St. Louis, Missouri
| | - Mario Castro
- Department of Internal Medicine, Division of Pulmonary and Critical Care Medicine, Washington University School of Medicine, St. Louis, Missouri
| | - Dmitriy A Yablonskiy
- Mallinckrodt Institute of Radiology, Washington University School of Medicine, St. Louis, Missouri;
| |
Collapse
|
19
|
Characterization of acinar airspace involvement in asthmatic patients by using inert gas washout and hyperpolarized (3)helium magnetic resonance. J Allergy Clin Immunol 2015; 137:417-25. [PMID: 26242298 DOI: 10.1016/j.jaci.2015.06.027] [Citation(s) in RCA: 24] [Impact Index Per Article: 2.7] [Reference Citation Analysis] [Abstract] [Key Words] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/16/2014] [Revised: 05/29/2015] [Accepted: 06/17/2015] [Indexed: 11/21/2022]
Abstract
BACKGROUND The multiple-breath inert gas washout parameter acinar ventilation heterogeneity (Sacin) is thought to be a marker of acinar airway involvement but has not been validated by using quantitative imaging techniques in asthmatic patients. OBJECTIVE We aimed to use hyperpolarized (3)He diffusion magnetic resonance at multiple diffusion timescales and quantitative computed tomographic (CT) densitometry to determine the nature of acinar airway involvement in asthmatic patients. METHODS Thirty-seven patients with asthma and 17 age-matched healthy control subjects underwent spirometry, body plethysmography, multiple-breath inert gas washout (with the tracer gas sulfur hexafluoride), and hyperpolarized (3)He diffusion magnetic resonance. A subset of asthmatic patients (n = 27) underwent quantitative CT densitometry. RESULTS Ninety-four percent (16/17) of patients with an increased Sacin had Global Initiative for Asthma treatment step 4 to 5 asthma, and 13 of 17 had refractory disease. The apparent diffusion coefficient (ADC) of (3)He at 1 second was significantly higher in patients with Sacin-high asthma compared with that in healthy control subjects (0.024 vs 0.017, P < .05). Sacin correlated strongly with ADCs at 1 second (R = 0.65, P < .001) but weakly with ADCs at 13 ms (R = 0.38, P < .05). ADCs at both 13 ms and 1 second correlated strongly with the mean lung density expiratory/inspiratory ratio, a CT marker of expiratory air trapping (R = 0.77, P < .0001 for ADCs at 13 ms; R = 0.72, P < .001 for ADCs at 1 second). CONCLUSION Sacin is associated with alterations in long-range diffusion within the acinar airways and gas trapping. The precise anatomic nature and mechanistic role in patients with severe asthma requires further evaluation.
Collapse
|
20
|
Chang YV, Quirk JD, Yablonskiy DA. In vivo lung morphometry with accelerated hyperpolarized (3) He diffusion MRI: a preliminary study. Magn Reson Med 2015; 73:1609-14. [PMID: 24799044 PMCID: PMC4221580 DOI: 10.1002/mrm.25284] [Citation(s) in RCA: 17] [Impact Index Per Article: 1.9] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/07/2013] [Revised: 04/11/2014] [Accepted: 04/15/2014] [Indexed: 12/27/2022]
Abstract
PURPOSE Parallel imaging can be used to reduce imaging time and to increase the spatial coverage in hyperpolarized gas magnetic resonance imaging of the lung. In this proof-of-concept study, we investigate the effects of parallel imaging on the morphometric measurement of lung microstructure using diffusion magnetic resonance imaging with hyperpolarized (3) He. METHODS Fully sampled and under-sampled multi-b diffusion data were acquired from human subjects using an 8-channel (3) He receive coil. A parallel imaging reconstruction technique (generalized autocalibrating partially parallel acquisitions [GRAPPA]) was used to reconstruct under-sampled k-space data. The morphometric results of the generalized autocalibrating partially parallel acquisitions-reconstructed data were compared with the results of fully sampled data for three types of subjects: healthy volunteers, mild, and moderate chronic obstructive pulmonary disease patients. RESULTS Morphometric measurements varied only slightly at mild acceleration factors. The results were largely well preserved compared to fully sampled data for different lung conditions. CONCLUSION Parallel imaging, given sufficient signal-to-noise ratio, provides a reliable means to accelerate hyperpolarized-gas magnetic resonance imaging with no significant difference in the measurement of lung morphometry from the fully sampled images. GRAPPA is a promising technique to significantly reduce imaging time and/or to improve the spatial coverage for the morphometric measurement with hyperpolarized gases.
Collapse
Affiliation(s)
- Yulin V Chang
- Biomedical Magnetic Resonance Laboratory, Mallinckrodt Institute of Radiology, Washington University, St. Louis, Missouri, USA
| | | | | |
Collapse
|
21
|
Quirk JD, Chang YV, Yablonskiy DA. In vivo lung morphometry with hyperpolarized (3) He diffusion MRI: reproducibility and the role of diffusion-sensitizing gradient direction. Magn Reson Med 2015; 73:1252-7. [PMID: 24752926 PMCID: PMC4205219 DOI: 10.1002/mrm.25241] [Citation(s) in RCA: 21] [Impact Index Per Article: 2.3] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/11/2013] [Revised: 03/13/2014] [Accepted: 03/14/2014] [Indexed: 12/25/2022]
Abstract
PURPOSE Lung morphometry with hyperpolarized gas diffusion MRI is a highly sensitive technique for the noninvasive measurement of acinar microstructural parameters traditionally only accessible by histology. The goal of this work is to establish the reproducibility of these measurements in healthy volunteers and their dependence on the direction of the applied diffusion-sensitizing gradient. METHODS Hyperpolarized helium-3 ((3) He) lung morphometry MRI was performed on a total of five healthy subjects. Two subjects received duplicate imaging on the same day and three subjects received duplicate imaging after a 4-month or 27-month delay to assess reproducibility. Four subjects repeated the measurement during the same session with different diffusion-sensitizing gradient directions to determine the effect on the parameter estimates. RESULTS The (3) He lung morphometry measurements were reproducible over the short term and long term (e.g., % coefficient of variation [CV] of mean chord length, Lm = 2.1% and 2.9%, respectively) and across different diffusion gradient directions (Lm % CV = 2.6%). Results also show independence of field inhomogeneity effects at 1.5T. CONCLUSION (3) He lung morphometry is a reproducible technique for measuring acinar microstructure and is effectively independent of the choice of diffusion gradient direction. This provides confidence for the use of this technique to compare populations and treatment efficacy.
Collapse
Affiliation(s)
- James D Quirk
- Mallinckrodt Institute of Radiology, Washington University School of Medicine, St. Louis, Missouri, USA
| | | | | |
Collapse
|
22
|
Ouriadov A, Farag A, Kirby M, McCormack DG, Parraga G, Santyr GE. Pulmonary hyperpolarized (129) Xe morphometry for mapping xenon gas concentrations and alveolar oxygen partial pressure: Proof-of-concept demonstration in healthy and COPD subjects. Magn Reson Med 2014; 74:1726-32. [PMID: 25483611 DOI: 10.1002/mrm.25550] [Citation(s) in RCA: 23] [Impact Index Per Article: 2.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/21/2014] [Revised: 11/03/2014] [Accepted: 11/05/2014] [Indexed: 12/25/2022]
Abstract
PURPOSE Diffusion-weighted (DW) hyperpolarized (129) Xe morphometry magnetic resonance imaging (MRI) can be used to map regional differences in lung tissue micro-structure. We aimed to generate absolute xenon concentration ([Xe]) and alveolar oxygen partial pressure (pA O2 ) maps by extracting the unrestricted diffusion coefficient (D0 ) of xenon as a morphometric parameter. METHODS In this proof-of-concept demonstration, morphometry was performed using multi b-value (0, 12, 20, 30 s/cm(2) ) DW hyperpolarized (129) Xe images obtained in four never-smokers and four COPD ex-smokers. Morphometric parameters and D0 maps were computed and the latter used to generate [Xe] and pA O2 maps. Xenon concentration phantoms estimating a range of values mimicking those observed in vivo were also investigated. RESULTS Xenon D0 was significantly increased (P = 0.035) in COPD (0.14 ± 0.03 cm(2) /s) compared with never-smokers (0.12 ± 0.02 cm(2) /s). COPD ex-smokers also had significantly decreased [Xe] (COPD = 8 ± 7% versus never-smokers = 13 ± 8%, P = 0.012) and increased pA O2 (COPD = 18 ± 3% versus never-smokers = 15 ± 3%, P = 0.009) compared with never-smokers. Phantom measurements showed the expected dependence of D0 on [Xe] over the range of concentrations anticipated in vivo. CONCLUSION DW hyperpolarized (129) Xe MRI morphometry can be used to simultaneously map [Xe] and pA O2 in addition to providing micro-structural biomarkers of emphysematous destruction in COPD. Phantom measurements of D0 ([Xe]) supported the hypotheses that differences in subjects may reflect differences in functional residual capacity.
Collapse
Affiliation(s)
- A Ouriadov
- Imaging Research Laboratories, Robarts Research Institute, Western University, London, Canada
| | - A Farag
- Imaging Research Laboratories, Robarts Research Institute, Western University, London, Canada
| | - M Kirby
- Department of Medical Biophysics, Western University, London, Canada.,James Hogg Research Centre, The University of British Columbia, and The Institute of Heart and Lung Health, St. Paul's Hospital, Vancouver, Canada
| | - D G McCormack
- Department of Medicine, Western University, London, Canada
| | - G Parraga
- Imaging Research Laboratories, Robarts Research Institute, Western University, London, Canada.,Department of Medical Biophysics, Western University, London, Canada.,Department of Medical Imaging, Western University, London, Canada Western University, London, Canada
| | - G E Santyr
- Imaging Research Laboratories, Robarts Research Institute, Western University, London, Canada.,Department of Medical Biophysics, Western University, London, Canada.,Department of Medical Imaging, Western University, London, Canada Western University, London, Canada.,Peter Gilgan Centre for Research and Learning, The Hospital for Sick Children, Toronto, Canada
| |
Collapse
|
23
|
Sukstanskii AL, Quirk JD, Yablonskiy DA. Probing lung microstructure with hyperpolarized 3He gradient echo MRI. NMR IN BIOMEDICINE 2014; 27:1451-60. [PMID: 24920182 PMCID: PMC4232999 DOI: 10.1002/nbm.3150] [Citation(s) in RCA: 6] [Impact Index Per Article: 0.6] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 01/17/2014] [Revised: 04/28/2014] [Accepted: 05/02/2014] [Indexed: 05/27/2023]
Abstract
In this paper we demonstrate that gradient echo MRI with hyperpolarized (3)He gas can be used for simultaneously extracting in vivo information about lung ventilation properties, alveolar geometrical parameters, and blood vessel network structure. This new approach is based on multi-gradient-echo experimental measurements of hyperpolarized (3)He gas MRI signal from human lungs and a proposed theoretical model of this signal. Based on computer simulations of (3)He atoms diffusing in the acinar airway tree in the presence of an inhomogeneous magnetic field induced by the susceptibility differences between lung tissue (alveolar septa, blood vessels) and lung airspaces, we derive analytical expressions relating the time-dependent MR signal to the geometrical parameters of acinar airways and the blood vessel network. Data obtained on eight healthy volunteers are in good agreement with literature values. This information is complementary to the information obtained by means of the in vivo lung morphometry technique with hyperpolarized 3He diffusion MRI previously developed by our group, and opens new opportunities to study lung microstructure in health and disease.
Collapse
Affiliation(s)
| | - James D Quirk
- Department of Radiology, Washington University, St. Louis MO, 63110, USA
| | | |
Collapse
|
24
|
Walkup LL, Woods JC. Translational applications of hyperpolarized 3He and 129Xe. NMR IN BIOMEDICINE 2014; 27:1429-1438. [PMID: 24953709 DOI: 10.1002/nbm.3151] [Citation(s) in RCA: 52] [Impact Index Per Article: 5.2] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 01/10/2014] [Revised: 04/07/2014] [Accepted: 05/19/2014] [Indexed: 06/03/2023]
Abstract
Clinical magnetic resonance imaging of the lung is technologically challenging, yet over the past two decades hyperpolarized noble gas ((3)He and (129)Xe) imaging has demonstrated the ability to measure multiple pulmonary functional biomarkers. There is a growing need for non-ionizing, non-invasive imaging techniques due to increased concern about cancer risk from ionizing radiation, but the translation of hyperpolarized gas imaging to the pulmonary clinic has been stunted by limited access to the technology. New developments may open doors to greater access and more translation to clinical studies. Here we briefly review a few translational applications of hyperpolarized gas MRI in the contexts of ventilation, diffusion, and dissolved-phase imaging, as well as comparing and contrasting (3)He and (129)Xe gases for these applications. Simple static ventilation MRI reveals regions of the lung not participating in normal ventilation, and these defects have been observed in many pulmonary diseases. Biomarkers related to airspace size and connectivity can be quantified by apparent diffusion coefficient measurements of hyperpolarized gas, and have been shown to be more sensitive to small changes in lung morphology than standard clinical pulmonary functional tests and have been validated by quantitative histology. Parameters related to gas uptake and exchange and lung tissue density can be determined using (129)Xe dissolved-phase MRI. In most cases functional biomarkers can be determined via MRI of either gas, but for some applications one gas may be preferred, such as (3)He for long-range diffusion measurements and (129)Xe for dissolved-phase imaging. Greater access to hyperpolarized gas imaging coupled with newly developing therapeutics makes pulmonary medicine poised for a potential revolution, further adding to the prospects of personalized medicine already evidenced by advancements in molecular biology. Hyperpolarized gas researchers have the opportunity to contribute to this revolution, particularly if greater clinical application of hyperpolarized gas imaging is realized.
Collapse
Affiliation(s)
- Laura L Walkup
- Center for Pulmonary Imaging Research, Cincinnati Children's Hospital Medical Center, Cincinnati, OH, USA
| | | |
Collapse
|
25
|
Yablonskiy DA, Sukstanskii AL, Conradi MS. Commentary on "The influence of lung airways branching structure and diffusion time on measurements and models of short-range 3He gas MR diffusion". JOURNAL OF MAGNETIC RESONANCE (SAN DIEGO, CALIF. : 1997) 2014; 239:139-42. [PMID: 24314822 PMCID: PMC3923313 DOI: 10.1016/j.jmr.2013.09.019] [Citation(s) in RCA: 6] [Impact Index Per Article: 0.6] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 01/03/2013] [Revised: 09/13/2013] [Accepted: 09/24/2013] [Indexed: 05/03/2023]
Abstract
In a recently published paper by Parra-Robles and Wild, the authors challenge the in vivo lung morphometry technique (based on hyperpolarized gas diffusion MRI) developed by our Washington University research group. In this Commentary we demonstrate that the main conclusion of Parra-Robles and Wild, that our MRI-based lung morphometry technique "produces inaccurate estimates of the airway dimensions", does not have any scientific basis and is not in agreement with the considerable body of peer-reviewed scientific reports as well as with Parra-Robles and Wild's own data. On the contrary, our technique has a strong theoretical background, is validated, and provides accurate 3D tomographic information on lung microstructural parameters previously available only from invasive biopsy specimens. This technique has already produced a number of results related to lung morphology and function that were not previously available. In our Commentary we also discuss a number of other incorrect statements in and shortcomings of Parra-Robles and Wild's paper.
Collapse
Affiliation(s)
| | | | - Mark S Conradi
- Department of Physics, Washington University, Saint Louis, MO 63130, USA; Department of Radiology, Washington University, Saint Louis, MO 63130, USA
| |
Collapse
|
26
|
Ackerman JJH. Magnetic resonance imaging: silicon for the future. NATURE NANOTECHNOLOGY 2013; 8:313-315. [PMID: 23648736 DOI: 10.1038/nnano.2013.82] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.1] [Reference Citation Analysis] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 06/02/2023]
|