1
|
Huang Z, Gambarota G, Xiao Y, Wenz D, Xin L. Apparent diffusion coefficients of 31P metabolites in the human calf muscle at 7 T. MAGMA 2023; 36:309-315. [PMID: 36752933 PMCID: PMC10140108 DOI: 10.1007/s10334-023-01065-3] [Citation(s) in RCA: 1] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Key Words] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 10/18/2022] [Revised: 01/05/2023] [Accepted: 01/19/2023] [Indexed: 04/28/2023]
Abstract
PURPOSE In this study, we aimed to measure the apparent diffusion coefficients (ADCs) of major phosphorous metabolites in the human calf muscle at 7 T with a diffusion-weighted (DW)-STEAM sequence. METHODS A DW-STEAM sequence with bipolar gradients was implemented at 7 T, and DW MR spectra were acquired in three orthogonal directions in the human calf muscle of six healthy volunteers (TE/TM/TR = 15 ms/750 ms/5 s) at three b-values (0, 800, and 1200 s/mm2). Frequency and phase alignments were applied prior to spectral averaging. Averaged DW MR spectra were analyzed with LCModel, and ADCs of 31P metabolites were estimated. RESULTS Four metabolites (phosphocreatine (PCr), adenosine triphosphate (ATP), inorganic phosphate (Pi) and glycerol phosphorylcholine (GPC)) were quantified at all b-values with mean CRLBs below 10%. The ADC values of PCr, ATP, Pi, and GPC were (0.24 ± 0.02, 0.15 ± 0.04, 0.43 ± 0.14, 0.40 ± 0.09) × 10-3 mm2/s, respectively. CONCLUSION The ADCs of four 31P metabolites were successfully measured in the human calf muscle at 7 T, among which those of ATP, Pi and GPC were reported for the first time in humans. This study paves the way to investigate 31P metabolite diffusion properties in health and disease on the clinical MR scanner.
Collapse
Affiliation(s)
- Zhiwei Huang
- Animal Imaging and Technology Core (AIT), Center for Biomedical Imaging (CIBM), Ecole Polytechnique Fédérale de Lausanne, Lausanne, Switzerland
- CIBM Center for Biomedical Imaging, EPFL CIBM-AIT, Station 6, CH-1015, Lausanne, Switzerland
| | | | - Ying Xiao
- Animal Imaging and Technology Core (AIT), Center for Biomedical Imaging (CIBM), Ecole Polytechnique Fédérale de Lausanne, Lausanne, Switzerland
- CIBM Center for Biomedical Imaging, EPFL CIBM-AIT, Station 6, CH-1015, Lausanne, Switzerland
| | - Daniel Wenz
- Animal Imaging and Technology Core (AIT), Center for Biomedical Imaging (CIBM), Ecole Polytechnique Fédérale de Lausanne, Lausanne, Switzerland
- CIBM Center for Biomedical Imaging, EPFL CIBM-AIT, Station 6, CH-1015, Lausanne, Switzerland
| | - Lijing Xin
- Animal Imaging and Technology Core (AIT), Center for Biomedical Imaging (CIBM), Ecole Polytechnique Fédérale de Lausanne, Lausanne, Switzerland.
- CIBM Center for Biomedical Imaging, EPFL CIBM-AIT, Station 6, CH-1015, Lausanne, Switzerland.
| |
Collapse
|
2
|
Sedivy P, Dezortova M, Drobny M, Dubsky M, Dusilova T, Kovar J, Hajek M. Origin of the 31 P MR signal at 5.3 ppm in patients with critical limb ischemia. NMR Biomed 2020; 33:e4295. [PMID: 32180296 DOI: 10.1002/nbm.4295] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 05/29/2019] [Revised: 02/28/2020] [Accepted: 02/29/2020] [Indexed: 06/10/2023]
Abstract
An unknown intense signal (Pun ) with a mean chemical shift of 5.3 ppm was observed in 31 P MR spectra from the calf muscles of patients with the diabetic foot syndrome. The aim of the study was to identify the origin of this signal and its potential as a biomarker of muscle injury. Calf muscles of 68 diabetic patients (66.3 ± 8.6 years; body mass index = 28.2 ± 4.3 kg/m2 ) and 12 age-matched healthy controls were examined by (dynamic) 31 P MRS (3 T system, 31 P/1 H coil). Phantoms (glucose-1-phosphate, Pi and PCr) were measured at pH values of 7.05 and 7.51. At rest, Pun signals with intensities higher than 50% of the Pi intensity were observed in 10 of the 68 examined diabetic subjects. We tested two hypothetical origins of the Pun signal: (1) phosphorus from phosphoesters and (2) phosphorus from extra- and intracellular alkaline phosphate pools. 2,3-diphosphoglycerate and glucose-1-phosphate are the only phosphoesters with signals in the chemical shift region close to 5.3 ppm. Both compounds can be excluded: 2,3-diphosphoglycerate due to the missing second signal component at 6.31 ppm; glucose-1-phosphate because its chemical shifts are about 0.2 ppm downfield from the Pi signal (4.9 ppm). If the Pun signal is from phosphate, it represents a pH value of 7.54 ± 0.05. Therefore, it could correspond to signals of Pi in mitochondria. However, patients with critical limb ischemia have rather few mitochondria and so the Pun signal probably originates from interstitia. Our data suggest that the increased Pun signal observed in patients with the diabetic foot syndrome is a biomarker of severe muscular damage.
Collapse
Affiliation(s)
- Petr Sedivy
- MR Unit, Department of Diagnostic and Interventional Radiology, Institute for Clinical and Experimental Medicine, Prague, Czech Republic
| | - Monika Dezortova
- MR Unit, Department of Diagnostic and Interventional Radiology, Institute for Clinical and Experimental Medicine, Prague, Czech Republic
| | - Miloslav Drobny
- MR Unit, Department of Diagnostic and Interventional Radiology, Institute for Clinical and Experimental Medicine, Prague, Czech Republic
| | - Michal Dubsky
- Department of Diabetology, Institute for Clinical and Experimental Medicine, Prague, Czech Republic
| | - Tereza Dusilova
- MR Unit, Department of Diagnostic and Interventional Radiology, Institute for Clinical and Experimental Medicine, Prague, Czech Republic
| | - Jan Kovar
- Experimental Medicine Centre, Institute for Clinical and Experimental Medicine, Prague, Czech Republic
| | - Milan Hajek
- MR Unit, Department of Diagnostic and Interventional Radiology, Institute for Clinical and Experimental Medicine, Prague, Czech Republic
| |
Collapse
|
3
|
Clarke WT, Peterzan MA, Rayner JJ, Sayeed RA, Petrou M, Krasopoulos G, Lake HA, Raman B, Watson WD, Cox P, Hundertmark MJ, Apps AP, Lygate CA, Neubauer S, Rider OJ, Rodgers CT. Localized rest and stress human cardiac creatine kinase reaction kinetics at 3 T. NMR Biomed 2019; 32:e4085. [PMID: 30920054 PMCID: PMC6542687 DOI: 10.1002/nbm.4085] [Citation(s) in RCA: 12] [Impact Index Per Article: 2.4] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 12/03/2018] [Revised: 01/24/2019] [Accepted: 01/28/2019] [Indexed: 05/11/2023]
Abstract
Changes in the kinetics of the creatine kinase (CK) shuttle are sensitive markers of cardiac energetics but are typically measured at rest and in the prone position. This study aims to measure CK kinetics during pharmacological stress at 3 T, with measurement in the supine position. A shorter "stressed saturation transfer" (StreST) extension to the triple repetition time saturation transfer (TRiST) method is proposed. We assess scanning in a supine position and validate the MR measurement against biopsy assay of CK activity. We report normal ranges of stress CK forward rate (kfCK ) for healthy volunteers and obese patients. TRiST measures kfCK in 40 min at 3 T. StreST extends the previously developed TRiST to also make a further kfCK measurement during <20 min of dobutamine stress. We test our TRiST implementation in skeletal muscle and myocardium in both prone and supine positions. We evaluate StreST in the myocardium of six healthy volunteers and 34 obese subjects. We validated MR-measured kfCK against biopsy assays of CK activity. TRiST kfCK values matched literature values in skeletal muscle (kfCK = 0.25 ± 0.03 s-1 vs 0.27 ± 0.03 s-1 ) and myocardium when measured in the prone position (0.32 ± 0.15 s-1 ), but a significant difference was found for TRiST kfCK measured supine (0.24 ± 0.12 s-1 ). This difference was because of different respiratory- and cardiac-motion-induced B0 changes in the two positions. Using supine TRiST, cardiac kfCK values for normal-weight subjects were 0.15 ± 0.09 s-1 at rest and 0.17 ± 0.15 s-1 during stress. For obese subjects, kfCK was 0.16 ± 0.07 s-1 at rest and 0.17 ± 0.10 s-1 during stress. Rest myocardial kfCK and CK activity from LV biopsies of the same subjects correlated (R = 0.43, p = 0.03). We present an independent implementation of TRiST on the Siemens platform using a commercially available coil. Our extended StreST protocol enables cardiac kfCK to be measured during dobutamine-induced stress in the supine position.
Collapse
Affiliation(s)
- William T. Clarke
- Oxford Centre for Clinical Magnetic Resonance Research (OCMR), Division of Cardiovascular Medicine RDMUniversity of Oxford, John Radcliffe HospitalOxfordUK
- Wellcome Centre for Integrative Neuroimaging, FMRIBUniversity of Oxford, John Radcliffe HospitalOxfordUK
| | - Mark A. Peterzan
- Oxford Centre for Clinical Magnetic Resonance Research (OCMR), Division of Cardiovascular Medicine RDMUniversity of Oxford, John Radcliffe HospitalOxfordUK
| | - Jennifer J. Rayner
- Oxford Centre for Clinical Magnetic Resonance Research (OCMR), Division of Cardiovascular Medicine RDMUniversity of Oxford, John Radcliffe HospitalOxfordUK
| | - Rana A. Sayeed
- Department of Cardiothoracic Surgery, John Radcliffe HospitalOxford University Hospitals NHS Foundation TrustOxfordUK
| | - Mario Petrou
- Department of Cardiothoracic Surgery, John Radcliffe HospitalOxford University Hospitals NHS Foundation TrustOxfordUK
| | - George Krasopoulos
- Department of Cardiothoracic Surgery, John Radcliffe HospitalOxford University Hospitals NHS Foundation TrustOxfordUK
| | - Hannah A. Lake
- Department of Cardiovascular MedicineUniversity of Oxford, Wellcome Trust Centre for Human GeneticsRoosevelt DriveOxfordUK
| | - Betty Raman
- Oxford Centre for Clinical Magnetic Resonance Research (OCMR), Division of Cardiovascular Medicine RDMUniversity of Oxford, John Radcliffe HospitalOxfordUK
| | - William D. Watson
- Oxford Centre for Clinical Magnetic Resonance Research (OCMR), Division of Cardiovascular Medicine RDMUniversity of Oxford, John Radcliffe HospitalOxfordUK
| | - Pete Cox
- Department of Physiology AnatomyUniversity of OxfordParks Road, Sherrington BuildingOxfordUK
| | - Moritz J. Hundertmark
- Oxford Centre for Clinical Magnetic Resonance Research (OCMR), Division of Cardiovascular Medicine RDMUniversity of Oxford, John Radcliffe HospitalOxfordUK
| | - Andrew P. Apps
- Oxford Centre for Clinical Magnetic Resonance Research (OCMR), Division of Cardiovascular Medicine RDMUniversity of Oxford, John Radcliffe HospitalOxfordUK
| | - Craig A. Lygate
- Department of Cardiovascular MedicineUniversity of Oxford, Wellcome Trust Centre for Human GeneticsRoosevelt DriveOxfordUK
| | - Stefan Neubauer
- Oxford Centre for Clinical Magnetic Resonance Research (OCMR), Division of Cardiovascular Medicine RDMUniversity of Oxford, John Radcliffe HospitalOxfordUK
| | - Oliver J. Rider
- Oxford Centre for Clinical Magnetic Resonance Research (OCMR), Division of Cardiovascular Medicine RDMUniversity of Oxford, John Radcliffe HospitalOxfordUK
| | - Christopher T. Rodgers
- Oxford Centre for Clinical Magnetic Resonance Research (OCMR), Division of Cardiovascular Medicine RDMUniversity of Oxford, John Radcliffe HospitalOxfordUK
- Wolfson Brain Imaging CentreUniversity of CambridgeBox 65, Cambridge Biomedical CampusCambridgeUK
| |
Collapse
|
4
|
Gonçalves SI, Ligneul C, Shemesh N. Short echo time relaxation‐enhanced MR spectroscopy reveals broad downfield resonances. Magn Reson Med 2019; 82:1266-1277. [DOI: 10.1002/mrm.27806] [Citation(s) in RCA: 8] [Impact Index Per Article: 1.6] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/28/2018] [Revised: 03/28/2019] [Accepted: 04/17/2019] [Indexed: 12/31/2022]
Affiliation(s)
- Sónia I. Gonçalves
- Champalimaud Research Champalimaud Centre for the Unknown Lisbon Portugal
| | - Clémence Ligneul
- Champalimaud Research Champalimaud Centre for the Unknown Lisbon Portugal
| | - Noam Shemesh
- Champalimaud Research Champalimaud Centre for the Unknown Lisbon Portugal
| |
Collapse
|
5
|
Ren J, Sherry AD, Malloy CR. Modular 31 P wideband inversion transfer for integrative analysis of adenosine triphosphate metabolism, T 1 relaxation and molecular dynamics in skeletal muscle at 7T. Magn Reson Med 2019; 81:3440-3452. [PMID: 30793793 DOI: 10.1002/mrm.27686] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.4] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Key Words] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/24/2018] [Revised: 01/16/2019] [Accepted: 01/18/2019] [Indexed: 12/13/2022]
Abstract
PURPOSE For efficient and integrative analysis of de novo adenosine triphosphate (ATP) synthesis, creatine-kinase-mediated ATP synthesis, T1 relaxation time, and ATP molecular motion dynamics in human skeletal muscle at rest. METHODS Four inversion-transfer modules differing in center inversion frequency were combined to generate amplified magnetization transfer (MT) effects in targeted MT pathways, including Pi ↔ γ-ATP, PCr ↔ γ-ATP, and 31 Pγ(α)ATP ↔ 31 PβATP . MT effects from both forward and reverse exchange kinetic pathways were acquired to reduce potential bias and confounding factors in integrated data analysis. RESULTS Kinetic data collected using 4 wideband inversion modules (8 minutes each) yielded the forward exchange rate constants, kPCr →γ ATP = 0.31 ± 0.05 s-1 and kPi →γ ATP = 0.064 ± 0.012 s-1 , and the reverse exchange rate constants, kγATP→Pi = 0.034 ± 0.006 s-1 and kγATP→PCr = 1.37 ± 0.22 s-1 , respectively. The cross-relaxation rate constant, σγ(α) ↔ βATP was -0.20 ± 0.03 s-1 , corresponding to ATP rotational correlation time τc of 0.8 ± 0.1 × 10-7 seconds. The intrinsic T1 relaxation times were Pi (9.2 ± 1.4 seconds), PCr (6.2 ± 0.4 seconds), γ-ATP (1.8 ± 0.1 seconds), α-ATP (1.4 ± 0.1 seconds), and β-ATP (1.1 ± 0.1 seconds). Muscle ATP T1 values were found to be significantly longer than those previously measured in the brain using a similar method. CONCLUSION A combination of multiple inversion transfer modules provides a comprehensive and integrated analysis of ATP metabolism and molecular motion dynamics. This relatively fast technique could be potentially useful for studying metabolic disorders in skeletal muscle.
Collapse
Affiliation(s)
- Jimin Ren
- Advanced Imaging Research Center, University of Texas Southwestern Medical Center, Dallas, Texas.,Department of Radiology, University of Texas Southwestern Medical Center, Dallas, Texas
| | - A Dean Sherry
- Advanced Imaging Research Center, University of Texas Southwestern Medical Center, Dallas, Texas.,Department of Radiology, University of Texas Southwestern Medical Center, Dallas, Texas.,Department of Chemistry, University of Texas at Dallas, Richardson, Texas
| | - Craig R Malloy
- Advanced Imaging Research Center, University of Texas Southwestern Medical Center, Dallas, Texas.,Department of Radiology, University of Texas Southwestern Medical Center, Dallas, Texas.,Department of Internal Medicine, University of Texas Southwestern Medical Center, Dallas, Texas.,VA North Texas Health Care System, Dallas, Texas
| |
Collapse
|
6
|
Purvis LAB, Clarke WT, Biasiolli L, Valkovič L, Robson MD, Rodgers CT. OXSA: An open-source magnetic resonance spectroscopy analysis toolbox in MATLAB. PLoS One 2017; 12:e0185356. [PMID: 28938003 PMCID: PMC5609763 DOI: 10.1371/journal.pone.0185356] [Citation(s) in RCA: 56] [Impact Index Per Article: 8.0] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/17/2017] [Accepted: 09/11/2017] [Indexed: 01/17/2023] Open
Abstract
In vivo magnetic resonance spectroscopy provides insight into metabolism in the human body. New acquisition protocols are often proposed to improve the quality or efficiency of data collection. Processing pipelines must also be developed to use these data optimally. Current fitting software is either targeted at general spectroscopy fitting, or for specific protocols. We therefore introduce the MATLAB-based OXford Spectroscopy Analysis (OXSA) toolbox to allow researchers to rapidly develop their own customised processing pipelines. The toolbox aims to simplify development by: being easy to install and use; seamlessly importing Siemens Digital Imaging and Communications in Medicine (DICOM) standard data; allowing visualisation of spectroscopy data; offering a robust fitting routine; flexibly specifying prior knowledge when fitting; and allowing batch processing of spectra. This article demonstrates how each of these criteria have been fulfilled, and gives technical details about the implementation in MATLAB. The code is freely available to download from https://github.com/oxsatoolbox/oxsa.
Collapse
Affiliation(s)
- Lucian A. B. Purvis
- Oxford Centre for Clinical Magnetic Resonance Research (OCMR), University of Oxford, John Radcliffe Hospital, Oxford, United Kingdom
- * E-mail:
| | - William T. Clarke
- Oxford Centre for Clinical Magnetic Resonance Research (OCMR), University of Oxford, John Radcliffe Hospital, Oxford, United Kingdom
| | - Luca Biasiolli
- Oxford Centre for Clinical Magnetic Resonance Research (OCMR), University of Oxford, John Radcliffe Hospital, Oxford, United Kingdom
| | - Ladislav Valkovič
- Oxford Centre for Clinical Magnetic Resonance Research (OCMR), University of Oxford, John Radcliffe Hospital, Oxford, United Kingdom
- Department of Imaging Methods, Institute of Measurement Science, Slovak Academy of Sciences, Bratislava, Slovakia
| | - Matthew D. Robson
- Oxford Centre for Clinical Magnetic Resonance Research (OCMR), University of Oxford, John Radcliffe Hospital, Oxford, United Kingdom
| | - Christopher T. Rodgers
- Oxford Centre for Clinical Magnetic Resonance Research (OCMR), University of Oxford, John Radcliffe Hospital, Oxford, United Kingdom
| |
Collapse
|
7
|
Purvis LAB, Clarke WT, Valkovič L, Levick C, Pavlides M, Barnes E, Cobbold JF, Robson MD, Rodgers CT. Phosphodiester content measured in human liver by in vivo 31 P MR spectroscopy at 7 tesla. Magn Reson Med 2017; 78:2095-2105. [PMID: 28244131 PMCID: PMC5697655 DOI: 10.1002/mrm.26635] [Citation(s) in RCA: 19] [Impact Index Per Article: 2.7] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Key Words] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/14/2016] [Revised: 01/13/2017] [Accepted: 01/17/2017] [Indexed: 12/19/2022]
Abstract
Purpose Phosphorus (31P) metabolites are emerging liver disease biomarkers. Of particular interest are phosphomonoester and phosphodiester (PDE) “peaks” that comprise multiple overlapping resonances in 31P spectra. This study investigates the effect of improved spectral resolution at 7 Tesla (T) on quantifying hepatic metabolites in cirrhosis. Methods Five volunteers were scanned to determine metabolite T1s. Ten volunteers and 11 patients with liver cirrhosis were scanned at 7T. Liver spectra were acquired in 28 min using a 16‐channel 31P array and 3D chemical shift imaging. Concentrations were calculated using γ‐adenosine‐triphosphate (γ‐ATP) = 2.65 mmol/L wet tissue. Results T1 means ± standard deviations: phosphatidylcholine 1.05 ± 0.28 s, nicotinamide‐adenine‐dinucleotide (NAD+) 2.0 ± 1.0 s, uridine‐diphosphoglucose (UDPG) 3.3 ± 1.4 s. Concentrations in healthy volunteers: α‐ATP 2.74 ± 0.11 mmol/L wet tissue, inorganic phosphate 2.23 ± 0.20 mmol/L wet tissue, glycerophosphocholine 2.34 ± 0.46 mmol/L wet tissue, glycerophosphoethanolamine 1.50 ± 0.28 mmol/L wet tissue, phosphocholine 1.06 ± 0.16 mmol/L wet tissue, phosphoethanolamine 0.77 ± 0.14 mmol/L wet tissue, NAD+ 2.37 ± 0.14 mmol/L wet tissue, UDPG 2.00 ± 0.22 mmol/L wet tissue, phosphatidylcholine 1.38 ± 0.31 mmol/L wet tissue. Inorganic phosphate and phosphatidylcholine concentrations were significantly lower in patients; glycerophosphoethanolamine concentrations were significantly higher (P < 0.05). Conclusion We report human in vivo hepatic T1s for phosphatidylcholine, NAD+, and UDPG for the first time at 7T. Our protocol allows high signal‐to‐noise, repeatable measurement of metabolite concentrations in human liver. The splitting of PDE into its constituent peaks at 7T may allow more insight into changes in metabolism. Magn Reson Med 78:2095–2105, 2017. © 2017 The Authors Magnetic Resonance in Medicine published by Wiley Periodicals, Inc. on behalf of International Society for Magnetic Resonance in Medicine. This is an open access article under the terms of the Creative Commons Attribution License, which permits use, distribution and reproduction in any medium, provided the original work is properly cited.
Collapse
Affiliation(s)
- Lucian A B Purvis
- Oxford Centre for Clinical Magnetic Resonance Research (OCMR), University of Oxford, Level 0, John Radcliffe Hospital, Oxford, United Kingdom
| | - William T Clarke
- Oxford Centre for Clinical Magnetic Resonance Research (OCMR), University of Oxford, Level 0, John Radcliffe Hospital, Oxford, United Kingdom
| | - Ladislav Valkovič
- Oxford Centre for Clinical Magnetic Resonance Research (OCMR), University of Oxford, Level 0, John Radcliffe Hospital, Oxford, United Kingdom.,Department of Imaging Methods, Institute of Measurement Science, Slovak Academy of Sciences, Bratislava, Slovakia
| | - Christina Levick
- Oxford Centre for Clinical Magnetic Resonance Research (OCMR), University of Oxford, Level 0, John Radcliffe Hospital, Oxford, United Kingdom
| | - Michael Pavlides
- Oxford Centre for Clinical Magnetic Resonance Research (OCMR), University of Oxford, Level 0, John Radcliffe Hospital, Oxford, United Kingdom.,Translational Gastroenterology Unit, University of Oxford, United Kingdom
| | - Eleanor Barnes
- Translational Gastroenterology Unit, University of Oxford, United Kingdom
| | - Jeremy F Cobbold
- Translational Gastroenterology Unit, University of Oxford, United Kingdom
| | - Matthew D Robson
- Oxford Centre for Clinical Magnetic Resonance Research (OCMR), University of Oxford, Level 0, John Radcliffe Hospital, Oxford, United Kingdom
| | - Christopher T Rodgers
- Oxford Centre for Clinical Magnetic Resonance Research (OCMR), University of Oxford, Level 0, John Radcliffe Hospital, Oxford, United Kingdom
| |
Collapse
|
8
|
Valkovič L, Chmelík M, Krššák M. In-vivo 31P-MRS of skeletal muscle and liver: A way for non-invasive assessment of their metabolism. Anal Biochem 2017; 529:193-215. [PMID: 28119063 PMCID: PMC5478074 DOI: 10.1016/j.ab.2017.01.018] [Citation(s) in RCA: 64] [Impact Index Per Article: 9.1] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/26/2016] [Revised: 01/13/2017] [Accepted: 01/19/2017] [Indexed: 01/18/2023]
Abstract
In addition to direct assessment of high energy phosphorus containing metabolite content within tissues, phosphorus magnetic resonance spectroscopy (31P-MRS) provides options to measure phospholipid metabolites and cellular pH, as well as the kinetics of chemical reactions of energy metabolism in vivo. Even though the great potential of 31P-MR was recognized over 30 years ago, modern MR systems, as well as new, dedicated hardware and measurement techniques provide further opportunities for research of human biochemistry. This paper presents a methodological overview of the 31P-MR techniques that can be used for basic, physiological, or clinical research of human skeletal muscle and liver in vivo. Practical issues of 31P-MRS experiments and examples of potential applications are also provided. As signal localization is essential for liver 31P-MRS and is important for dynamic muscle examinations as well, typical localization strategies for 31P-MR are also described.
Collapse
Affiliation(s)
- Ladislav Valkovič
- High-field MR Centre, Department of Biomedical Imaging and Image-guided Therapy, Medical University of Vienna, Vienna, Austria; Oxford Centre for Clinical Magnetic Resonance Research (OCMR), University of Oxford, Oxford, United Kingdom; Department of Imaging Methods, Institute of Measurement Science, Slovak Academy of Sciences, Bratislava, Slovakia.
| | - Marek Chmelík
- High-field MR Centre, Department of Biomedical Imaging and Image-guided Therapy, Medical University of Vienna, Vienna, Austria; Christian Doppler Laboratory for Clinical Molecular MR Imaging, Vienna, Austria; Institute for Clinical Molecular MRI in Musculoskeletal System, Karl Landsteiner Society, Vienna, Austria
| | - Martin Krššák
- High-field MR Centre, Department of Biomedical Imaging and Image-guided Therapy, Medical University of Vienna, Vienna, Austria; Christian Doppler Laboratory for Clinical Molecular MR Imaging, Vienna, Austria; Division of Endocrinology and Metabolism, Department of Internal Medicine III, Medical University of Vienna, Vienna, Austria
| |
Collapse
|
9
|
Ren J, Sherry AD, Malloy CR. A simple approach to evaluate the kinetic rate constant for ATP synthesis in resting human skeletal muscle at 7 T. NMR Biomed 2016; 29:1240-8. [PMID: 25943328 PMCID: PMC4673044 DOI: 10.1002/nbm.3310] [Citation(s) in RCA: 6] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 10/06/2014] [Revised: 03/25/2015] [Accepted: 03/27/2015] [Indexed: 05/11/2023]
Abstract
Inversion transfer (IT) is a well-established technique with multiple attractive features for analysis of kinetics. However, its application in measurement of ATP synthesis rate in vivo has lagged behind the more common saturation transfer (ST) techniques. One well-recognized issue with IT is the complexity of data analysis in comparison with much simpler analysis by ST. This complexity arises, in part, because the γ-ATP spin is involved in multiple chemical reactions and magnetization exchanges, whereas Pi is involved in a single reaction, Pi → γ-ATP. By considering the reactions involving γ-ATP only as a lumped constant, the rate constant for the reaction of physiological interest, kPi→γATP , can be determined. Here, we present a new IT data analysis method to evaluate kPi→γATP using data collected from resting human skeletal muscle at 7 T. The method is based on the basic Bloch-McConnell equation, which relates kPi→γATP to m˙Pi, the rate of Pi magnetization change. The kPi→γATP value is accessed from m˙Pi data by more familiar linear correlation approaches. For a group of human subjects (n = 15), the kPi→γATP value derived for resting calf muscle was 0.066 ± 0.017 s(-1) , in agreement with literature-reported values. In this study we also explored possible time-saving strategies to speed up data acquisition for kPi→γATP evaluation using simulations. The analysis indicates that it is feasible to carry out a (31) P IT experiment in about 10 min or less at 7 T with reasonable outcome in kPi→γATP variance for measurement of ATP synthesis in resting human skeletal muscle. We believe that this new IT data analysis approach will facilitate the wide acceptance of IT to evaluate ATP synthesis rate in vivo. Copyright © 2015 John Wiley & Sons, Ltd.
Collapse
Affiliation(s)
- Jimin Ren
- Advanced Imaging Research Center, University of Texas Southwestern Medical Center, Dallas, TX75390
- Department of Radiology, University of Texas Southwestern Medical Center, Dallas, TX75390
| | - A. Dean Sherry
- Advanced Imaging Research Center, University of Texas Southwestern Medical Center, Dallas, TX75390
- Department of Radiology, University of Texas Southwestern Medical Center, Dallas, TX75390
- Department of Chemistry, University of Texas at Dallas, Richardson, TX75080
| | - Craig R. Malloy
- Advanced Imaging Research Center, University of Texas Southwestern Medical Center, Dallas, TX75390
- Department of Radiology, University of Texas Southwestern Medical Center, Dallas, TX75390
- Department of Internal Medicine, University of Texas Southwestern Medical Center, Dallas, TX75390
- VA North Texas Health Care System, Dallas, TX75216
| |
Collapse
|
10
|
Tušek Jelenc M, Chmelík M, Bogner W, Krššák M, Trattnig S, Valkovič L. Feasibility and repeatability of localized (31) P-MRS four-angle saturation transfer (FAST) of the human gastrocnemius muscle using a surface coil at 7 T. NMR Biomed 2016; 29:57-65. [PMID: 26684051 PMCID: PMC4833172 DOI: 10.1002/nbm.3445] [Citation(s) in RCA: 11] [Impact Index Per Article: 1.4] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 07/02/2015] [Revised: 09/28/2015] [Accepted: 10/20/2015] [Indexed: 05/11/2023]
Abstract
Phosphorus ((31) P) MRS, combined with saturation transfer (ST), provides non-invasive insight into muscle energy metabolism. However, even at 7 T, the standard ST method with T1 (app) measured by inversion recovery takes about 10 min, making it impractical for dynamic examinations. An alternative method, i.e. four-angle saturation transfer (FAST), can shorten the examination time. The aim of this study was to test the feasibility, repeatability, and possible time resolution of the localized FAST technique measurement on an ultra-high-field MR system, to accelerate the measurement of both Pi -to-ATP and PCr-to-ATP reaction rates in the human gastrocnemius muscle and to test the feasibility of using the FAST method for dynamic measurements. We measured the exchange rates and metabolic fluxes in the gastrocnemius muscle of eight healthy subjects at 7 T with the depth-resolved surface coil MRS (DRESS)-localized FAST method. For comparison, a standard ST localized method was also used. The measurement time for the localized FAST experiment was 3.5 min compared with the 10 min for the standard localized ST experiment. In addition, in five healthy volunteers, Pi -to-ATP and PCr-to-ATP metabolic fluxes were measured in the gastrocnemius muscle at rest and during plantar flexion by the DRESS-localized FAST method. The repeatability of PCr-to-ATP and Pi -to-ATP exchange rate constants, determined by the slab-selective localized FAST method at 7 T, is high, as the coefficients of variation remained below 20%, and the results of the exchange rates measured with the FAST method are comparable to those measured with standard ST. During physical activity, the PCr-to-ATP metabolic flux decreased (from FCK = 8.21 ± 1.15 mM s(-1) to FCK = 3.86 ± 1.38 mM s(-1) ) and the Pi -to-ATP flux increased (from FATP = 0.43 ± 0.14 mM s(-1) to FATP = 0.74 ± 0.13 mM s(-1) ). In conclusion, we could demonstrate that measurements in the gastrocnemius muscle are feasible at rest and are short enough to be used during exercise with the DRESS-localized FAST method at 7 T.
Collapse
Affiliation(s)
- Marjeta Tušek Jelenc
- High Field MR Centre, Department of Biomedical Imaging and Image-Guided Therapy, Medical University of Vienna, Vienna, Austria
- Christian Doppler Laboratory for Clinical Molecular MR Imaging, Vienna, Austria
| | - Marek Chmelík
- High Field MR Centre, Department of Biomedical Imaging and Image-Guided Therapy, Medical University of Vienna, Vienna, Austria
- Christian Doppler Laboratory for Clinical Molecular MR Imaging, Vienna, Austria
| | - Wolfgang Bogner
- High Field MR Centre, Department of Biomedical Imaging and Image-Guided Therapy, Medical University of Vienna, Vienna, Austria
- Christian Doppler Laboratory for Clinical Molecular MR Imaging, Vienna, Austria
| | - Martin Krššák
- High Field MR Centre, Department of Biomedical Imaging and Image-Guided Therapy, Medical University of Vienna, Vienna, Austria
- Christian Doppler Laboratory for Clinical Molecular MR Imaging, Vienna, Austria
- Division of Endocrinology and Metabolism, Department of Internal Medicine III, Medical University of Vienna, Vienna, Austria
| | - Siegfried Trattnig
- High Field MR Centre, Department of Biomedical Imaging and Image-Guided Therapy, Medical University of Vienna, Vienna, Austria
- Christian Doppler Laboratory for Clinical Molecular MR Imaging, Vienna, Austria
| | - Ladislav Valkovič
- High Field MR Centre, Department of Biomedical Imaging and Image-Guided Therapy, Medical University of Vienna, Vienna, Austria
- Christian Doppler Laboratory for Clinical Molecular MR Imaging, Vienna, Austria
- Department of Imaging Methods, Institute of Measurement Science, Slovak Academy of Sciences, Bratislava, Slovakia
- Oxford Centre for Clinical MR Research (OCMR), University of Oxford, United Kingdom
| |
Collapse
|
11
|
Šedivý P, Kipfelsberger MC, Dezortová M, Krššák M, Drobný M, Chmelík M, Rydlo J, Trattnig S, Hájek M, Valkovič L. Dynamic 31P MR spectroscopy of plantar flexion: influence of ergometer design, magnetic field strength (3 and 7 T), and RF-coil design. Med Phys 2015; 42:1678-89. [PMID: 25832057 DOI: 10.1118/1.4914448] [Citation(s) in RCA: 22] [Impact Index Per Article: 2.4] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/07/2022] Open
Abstract
PURPOSE Dynamic phosphorus magnetic resonance spectroscopy ((31)P MRS) during and after acute exercise enables the noninvasive in vivo determination of the mitochondrial capacity of skeletal muscle. Nevertheless, the lack of standardization in experimental setups leads to significant variations in published values of maximal aerobic capacity, even in the population of healthy volunteers. Thus, in this study, we aimed to assess the impact of the ergometer type (pneumatic and mechanical resistance construction), radiofrequency (RF)-coil diameter, and different magnetic field strengths (3 and 7 T) on the metabolic parameters measured by dynamic (31)P MRS during a plantar flexion isotonic exercise protocol within the same group of healthy volunteers. METHODS Dynamic (31)P MRS measurements of the calf muscle in 11 volunteers (mean age, 36 ± 13 yrs; mean BMI, 23.5 ± 2.5 kg/m(2)), on a 3 T MR system with a custom-made mechanical ergometer in the first research laboratory (RL1) and on 3 and 7 T MR systems equipped with a commercial pneumatic ergometer in the second research laboratory (RL2), were performed at three different workloads. RF-coils differed slightly between the sites and MR systems used. The repeatability of the experimental protocol was tested in every setup. The basal concentrations of phosphocreatine (PCr), exercise-induced depletion of PCr (ΔPCr), initial PCr resynthesis rate (VPCr), and mitochondrial capacity (Qmax) were calculated and compared between the research sites and field strengths. RESULTS High repeatability of the measurement protocol was found in every experimental setup. No significant differences at any workload were found in these metabolic parameters assessed at different magnetic field strengths (3 T vs 7 T), using the same ergometer (in RL2) and a similar RF-coil. In the inter-research laboratory comparison at the same field strength (3 T), but with using different ergometers and RF-coils, differences were found in the concentration of PCr measured at rest and in the drop in PCr signal intensity. These differences translated into difference in the value of mitochondrial capacity at a workload of 15% of maximal voluntary contraction (MVC) force (0.45 ± 0.16 mM/s vs 0.31 ± 0.08 mM/s, in the RL1 and RL2, respectively). CONCLUSIONS Metabolic parameters measured during exercise challenge by dynamic (31)P MRS do not depend upon the magnetic field strength used. For multicenter studies with different ergometers, it is important to set the same workload, measurement, and evaluation protocols, especially when the effects of very mild exercise (15% MVC) are to be compared. However, a higher workload (24% MVC) decreases the influence of imperfections and intersite differences for the assessed value of maximal mitochondrial capacity.
Collapse
Affiliation(s)
- Petr Šedivý
- MR-Unit, Department of Diagnostic and Interventional Radiology, Institute for Clinical and Experimental Medicine, Prague 140 21, Czech Republic
| | - Monika Christina Kipfelsberger
- High-Field MR Centre, Department of Biomedical Imaging and Image-guided Therapy, Medical University of Vienna, Vienna A-1090, Austria and Christian Doppler Laboratory for Clinical Molecular MR Imaging, Vienna A-1090, Austria
| | - Monika Dezortová
- MR-Unit, Department of Diagnostic and Interventional Radiology, Institute for Clinical and Experimental Medicine, Prague 140 21, Czech Republic
| | - Martin Krššák
- High-Field MR Centre, Department of Biomedical Imaging and Image-guided Therapy, Medical University of Vienna, Vienna A-1090, Austria; Division of Endocrinology and Metabolism, Department of Internal Medicine III, Medical University of Vienna, Vienna A-1090, Austria; and Christian Doppler Laboratory for Clinical Molecular MR Imaging, Vienna A-1090, Austria
| | - Miloslav Drobný
- MR-Unit, Department of Diagnostic and Interventional Radiology, Institute for Clinical and Experimental Medicine, Prague 140 21, Czech Republic
| | - Marek Chmelík
- High-Field MR Centre, Department of Biomedical Imaging and Image-guided Therapy, Medical University of Vienna, Vienna A-1090, Austria and Christian Doppler Laboratory for Clinical Molecular MR Imaging, Vienna A-1090, Austria
| | - Jan Rydlo
- MR-Unit, Department of Diagnostic and Interventional Radiology, Institute for Clinical and Experimental Medicine, Prague 140 21, Czech Republic
| | - Siegfried Trattnig
- High-Field MR Centre, Department of Biomedical Imaging and Image-guided Therapy, Medical University of Vienna, Vienna A-1090, Austria and Christian Doppler Laboratory for Clinical Molecular MR Imaging, Vienna A-1090, Austria
| | - Milan Hájek
- MR-Unit, Department of Diagnostic and Interventional Radiology, Institute for Clinical and Experimental Medicine, Prague 140 21, Czech Republic
| | - Ladislav Valkovič
- High-Field MR Centre, Department of Biomedical Imaging and Image-guided Therapy, Medical University of Vienna, Vienna A-1090, Austria; Department of Imaging Methods, Institute of Measurement Science, Slovak Academy of Sciences, Bratislava 841 04, Slovakia; and Christian Doppler Laboratory for Clinical Molecular MR Imaging, Vienna A-1090, Austria
| |
Collapse
|
12
|
Ren J, Sherry AD, Malloy CR. Amplification of the effects of magnetization exchange by (31) P band inversion for measuring adenosine triphosphate synthesis rates in human skeletal muscle. Magn Reson Med 2015; 74:1505-14. [PMID: 25469992 PMCID: PMC4792267 DOI: 10.1002/mrm.25514] [Citation(s) in RCA: 13] [Impact Index Per Article: 1.4] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/06/2014] [Revised: 09/23/2014] [Accepted: 10/09/2014] [Indexed: 01/06/2023]
Abstract
PURPOSE The goal of this study was to amplify the effects of magnetization exchange between γ-adenosine triphosphate (ATP) and inorganic phosphate (Pi) for evaluation of ATP synthesis rates in human skeletal muscle. METHODS The strategy works by simultaneously inverting the (31) P resonances of phosphocreatine (PCr) and ATP using a wide bandwidth, adiabatic inversion radiofrequency pulse followed by observing dynamic changes in intensity of the noninverted Pi signal versus the delay time between the inversion and observation pulses. This band inversion technique significantly delays recovery of γ-ATP magnetization; consequently, the exchange reaction, Pi ↔ γ-ATP, is readily detected and easily analyzed. RESULTS The ATP synthesis rate measured from high-quality spectral data using this method was 0.073 ± 0.011 s(-1) in resting human skeletal muscle (N = 10). The T1 of Pi was 6.93 ± 1.90 s, consistent with the intrinsic T1 of Pi at this field. The apparent T1 of γ-ATP was 4.07 ± 0.32 s, about two-fold longer than its intrinsic T1 due to storage of magnetization in PCr. CONCLUSION Band inversion provides an effective method to amplify the effects of magnetization transfer between γ-ATP and Pi. The resulting data can be easily analyzed to obtain the ATP synthesis rate using a two-site exchange model.
Collapse
Affiliation(s)
- Jimin Ren
- Advanced Imaging Research Center, University of Texas Southwestern Medical Center, Dallas, TX75390
- Department of Radiology, University of Texas Southwestern Medical Center, Dallas, TX75390
| | - A. Dean Sherry
- Advanced Imaging Research Center, University of Texas Southwestern Medical Center, Dallas, TX75390
- Department of Radiology, University of Texas Southwestern Medical Center, Dallas, TX75390
- Department of Chemistry, University of Texas at Dallas, Richardson, TX75080
| | - Craig R. Malloy
- Advanced Imaging Research Center, University of Texas Southwestern Medical Center, Dallas, TX75390
- Department of Radiology, University of Texas Southwestern Medical Center, Dallas, TX75390
- Department of Internal Medicine, University of Texas Southwestern Medical Center, Dallas, TX75390
- VA North Texas Health Care System, Dallas, TX75216
| |
Collapse
|
13
|
Ren J, Sherry AD, Malloy CR. (31)P-MRS of healthy human brain: ATP synthesis, metabolite concentrations, pH, and T1 relaxation times. NMR Biomed 2015; 28:1455-62. [PMID: 26404723 PMCID: PMC4772768 DOI: 10.1002/nbm.3384] [Citation(s) in RCA: 63] [Impact Index Per Article: 7.0] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 06/09/2015] [Revised: 07/22/2015] [Accepted: 07/24/2015] [Indexed: 05/18/2023]
Abstract
The conventional method for measuring brain ATP synthesis is (31)P saturation transfer (ST), a technique typically dependent on prolonged pre-saturation with γ-ATP. In this study, ATP synthesis rate in resting human brain is evaluated using EBIT (exchange kinetics by band inversion transfer), a technique based on slow recovery of γ-ATP magnetization in the absence of B1 field following co-inversion of PCr and ATP resonances with a short adiabatic pulse. The unidirectional rate constant for the Pi → γ-ATP reaction is 0.21 ± 0.04 s(-1) and the ATP synthesis rate is 9.9 ± 2.1 mmol min(-1) kg(-1) in human brain (n = 12 subjects), consistent with the results by ST. Therefore, EBIT could be a useful alternative to ST in studying brain energy metabolism in normal physiology and under pathological conditions. In addition to ATP synthesis, all detectable (31)P signals are analyzed to determine the brain concentration of phosphorus metabolites, including UDPG at around 10 ppm, a previously reported resonance in liver tissues and now confirmed in human brain. Inversion recovery measurements indicate that UDPG, like its diphosphate analogue NAD, has apparent T1 shorter than that of monophosphates (Pi, PMEs, and PDEs) but longer than that of triphosphate ATP, highlighting the significance of the (31)P-(31)P dipolar mechanism in T1 relaxation of polyphosphates. Another interesting finding is the observation of approximately 40% shorter T1 for intracellular Pi relative to extracellular Pi, attributed to the modulation by the intracellular phosphoryl exchange reaction Pi ↔ γ-ATP. The sufficiently separated intra- and extracellular Pi signals also permit the distinction of pH between intra- and extracellular environments (pH 7.0 versus pH 7.4). In summary, quantitative (31)P MRS in combination with ATP synthesis, pH, and T1 relaxation measurements may offer a promising tool to detect biochemical alterations at early stages of brain dysfunctions and diseases.
Collapse
Affiliation(s)
- Jimin Ren
- Advanced Imaging Research Center, University of Texas Southwestern Medical Center, Dallas, TX 75390
- Department of Radiology, University of Texas Southwestern Medical Center, Dallas, TX 75390
| | - A. Dean Sherry
- Advanced Imaging Research Center, University of Texas Southwestern Medical Center, Dallas, TX 75390
- Department of Radiology, University of Texas Southwestern Medical Center, Dallas, TX 75390
- Department of Chemistry, University of Texas at Dallas, Richardson, TX 75080
| | - Craig R. Malloy
- Advanced Imaging Research Center, University of Texas Southwestern Medical Center, Dallas, TX 75390
- Department of Radiology, University of Texas Southwestern Medical Center, Dallas, TX 75390
- Department of Internal Medicine, University of Texas Southwestern Medical Center, Dallas, TX 75390
- VA North Texas Health Care System, Dallas, TX 75216
- To whom correspondence should be addressed: Craig R. Malloy, 5323 Harry Hines Blvd, NE4.2, Dallas, Texas 75390-8568, USA, (214) 645-2722,
| |
Collapse
|
14
|
Schaller B, Clarke WT, Neubauer S, Robson MD, Rodgers CT. Suppression of skeletal muscle signal using a crusher coil: A human cardiac (31) p-MR spectroscopy study at 7 tesla. Magn Reson Med 2015; 75:962-72. [PMID: 25924813 PMCID: PMC4762536 DOI: 10.1002/mrm.25755] [Citation(s) in RCA: 10] [Impact Index Per Article: 1.1] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/21/2014] [Revised: 04/08/2015] [Accepted: 04/09/2015] [Indexed: 12/19/2022]
Abstract
Purpose The translation of sophisticated phosphorus MR spectroscopy (31P‐MRS) protocols to 7 Tesla (T) is particularly challenged by the issue of radiofrequency (RF) heating. Legal limits on RF heating make it hard to reliably suppress signals from skeletal muscle that can contaminate human cardiac 31P spectra at 7T. We introduce the first surface‐spoiling crusher coil for human cardiac 31P‐MRS at 7T. Methods A planar crusher coil design was optimized with simulations and its performance was validated in phantoms. Crusher gradient pulses (100 μs) were then applied during human cardiac 31P‐MRS at 7T. Results In a phantom, residual signals were 50 ± 10% with BISTRO (B1‐insensitive train to obliterate signal), and 34 ± 8% with the crusher coil. In vivo, residual signals in skeletal muscle were 49 ± 4% using BISTRO, and 24 ± 5% using the crusher coil. Meanwhile, in the interventricular septum, spectral quality and metabolite quantification did not differ significantly between BISTRO (phosphocreatine/adenosine triphosphate [PCr/ATP] = 2.1 ± 0.4) and the crusher coil (PCr/ATP = 1.8 ± 0.4). However, the specific absorption rate (SAR) decreased from 96 ± 1% of the limit (BISTRO) to 16 ± 1% (crusher coil). Conclusion A crusher coil is an SAR‐efficient alternative for selectively suppressing skeletal muscle during cardiac 31P‐MRS at 7T. A crusher coil allows the use of sequence modules that would have been SAR‐prohibitive, without compromising skeletal muscle suppression. Magn Reson Med 75:962–972, 2016. © 2015 The Authors. Magnetic Resonance in Medicine Published by Wiley Periodicals, Inc. on behalf of International Society of Medicine in Resonance.
Collapse
Affiliation(s)
- Benoit Schaller
- University of Oxford Centre for Clinical Magnetic Resonance Research (OCMR), University of Oxford, Level 0, John Radcliffe Hospital, Oxford, United Kingdom
| | - William T Clarke
- University of Oxford Centre for Clinical Magnetic Resonance Research (OCMR), University of Oxford, Level 0, John Radcliffe Hospital, Oxford, United Kingdom
| | - Stefan Neubauer
- University of Oxford Centre for Clinical Magnetic Resonance Research (OCMR), University of Oxford, Level 0, John Radcliffe Hospital, Oxford, United Kingdom
| | - Matthew D Robson
- University of Oxford Centre for Clinical Magnetic Resonance Research (OCMR), University of Oxford, Level 0, John Radcliffe Hospital, Oxford, United Kingdom
| | - Christopher T Rodgers
- University of Oxford Centre for Clinical Magnetic Resonance Research (OCMR), University of Oxford, Level 0, John Radcliffe Hospital, Oxford, United Kingdom
| |
Collapse
|
15
|
Parasoglou P, Xia D, Regatte RR. Feasibility of mapping unidirectional Pi-to-ATP fluxes in muscles of the lower leg at 7.0 Tesla. Magn Reson Med 2014; 74:225-230. [PMID: 25078605 DOI: 10.1002/mrm.25388] [Citation(s) in RCA: 5] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/07/2014] [Revised: 06/10/2014] [Accepted: 07/05/2014] [Indexed: 12/16/2022]
Abstract
PURPOSE To assess the feasibility of mapping the kinetics and unidirectional fluxes of inorganic phosphate (Pi) to adenosine triphosphate (ATP) reactions in the entire volume of the lower leg muscles using a three-dimensional saturation transfer (ST) phosphorus (31 P) imaging sequence. THEORY AND METHODS We imaged the lower leg muscles of five healthy subjects at 7.0 Tesla. The total experimental time was 45 min. We quantified muscle-specific forward reaction rate constants (k'f ) and metabolic fluxes (Vf ) of the Pi-to-ATP reaction in the tibialis anterior, the gastrocnemius, and the soleus. RESULTS In the tibialis anterior, k'f and Vf were 0.11 s-1 ± 0.03 (mean ± standard deviation) and 0.34 mM s-1 ± 0.10, respectively. In the gastrocnemius, k'f was 0.11 s-1 ± 0.04 and Vf was 0.37 mM s-1 ± 0.11, while in the soleus muscle k'f was 0.10 s-1 ± 0.02 and Vf was 0.36 mM s-1 ± 0.14. CONCLUSION Our results suggest that mapping the kinetics and unidirectional fluxes from Pi-to-ATP in both the anterior and posterior muscles of the lower leg is feasible at ultra-high field and may provide useful insights for the study of insulin resistance, diabetes and aging. Magn Reson Med 74:225-230, 2015. © 2014 Wiley Periodicals, Inc.
Collapse
Affiliation(s)
- Prodromos Parasoglou
- Quantitative Multinuclear Musculoskeletal Imaging Group (QMMIG), Department of Radiology, Center for Biomedical Imaging, New York University Langone Medical Center, New York, New York, USA
| | - Ding Xia
- Quantitative Multinuclear Musculoskeletal Imaging Group (QMMIG), Department of Radiology, Center for Biomedical Imaging, New York University Langone Medical Center, New York, New York, USA
| | - Ravinder R Regatte
- Quantitative Multinuclear Musculoskeletal Imaging Group (QMMIG), Department of Radiology, Center for Biomedical Imaging, New York University Langone Medical Center, New York, New York, USA
| |
Collapse
|
16
|
Valkovič L, Gajdošík M, Traussnigg S, Wolf P, Chmelík M, Kienbacher C, Bogner W, Krebs M, Trauner M, Trattnig S, Krššák M. Application of localized ³¹P MRS saturation transfer at 7 T for measurement of ATP metabolism in the liver: reproducibility and initial clinical application in patients with non-alcoholic fatty liver disease. Eur Radiol 2014; 24:1602-9. [PMID: 24647824 DOI: 10.1007/s00330-014-3141-x] [Citation(s) in RCA: 19] [Impact Index Per Article: 1.9] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/11/2013] [Revised: 02/10/2014] [Accepted: 02/27/2014] [Indexed: 12/27/2022]
Abstract
OBJECTIVES Saturation transfer (ST) phosphorus MR spectroscopy ((31)P MRS) enables in vivo insight into energy metabolism and thus could identify liver conditions currently diagnosed only by biopsy. This study assesses the reproducibility of the localized (31)P MRS ST in liver at 7 T and tests its potential for noninvasive differentiation of non-alcoholic fatty liver (NAFL) and steatohepatitis (NASH). METHODS After the ethics committee approval, reproducibility of the localized (31)P MRS ST at 7 T and the biological variation of acquired hepato-metabolic parameters were assessed in healthy volunteers. Subsequently, 16 suspected NAFL/NASH patients underwent MRS measurements and diagnostic liver biopsy. The Pi-to-ATP exchange parameters were compared between the groups by a Mann-Whitney U test and related to the liver fat content estimated by a single-voxel proton ((1)H) MRS, measured at 3 T. RESULTS The mean exchange rate constant (k) in healthy volunteers was 0.31 ± 0.03 s(-1) with a coefficient of variation of 9.0 %. Significantly lower exchange rates (p < 0.01) were found in NASH patients (k = 0.17 ± 0.04 s(-1)) when compared to healthy volunteers, and NAFL patients (k = 0.30 ± 0.05 s(-1)). Significant correlation was found between the k value and the liver fat content (r = 0.824, p < 0.01). CONCLUSIONS Our data suggest that the (31)P MRS ST technique provides a tool for gaining insight into hepatic ATP metabolism and could contribute to the differentiation of NAFL and NASH. KEY POINTS • 1D localized (31) P MRS saturation transfer in the liver is reproducible at 7 T • NASH patients have decreased hepatic Pi-to-ATP exchange rate • In this study, hepatic metabolic activity correlates with liver fat content.
Collapse
Affiliation(s)
- Ladislav Valkovič
- High Field MR Centre, Department of Biomedical Imaging and Image-guided Therapy, Medical University of Vienna, Vienna, Austria
| | | | | | | | | | | | | | | | | | | | | |
Collapse
|