1
|
Kim KH, Seo S, Do WJ, Luu HM, Park SH. Varying undersampling directions for accelerating multiple acquisition magnetic resonance imaging. NMR IN BIOMEDICINE 2022; 35:e4572. [PMID: 34114253 DOI: 10.1002/nbm.4572] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 04/29/2020] [Revised: 05/27/2021] [Accepted: 05/27/2021] [Indexed: 06/12/2023]
Abstract
In this study, we propose a new sampling strategy for efficiently accelerating multiple acquisition MRI. The new sampling strategy is to obtain data along different phase-encoding directions across multiple acquisitions. The proposed sampling strategy was evaluated in multicontrast MR imaging (T1, T2, proton density) and multiple phase-cycled (PC) balanced steady-state free precession (bSSFP) imaging by using convolutional neural networks with central and random sampling patterns. In vivo MRI acquisitions as well as a public database were used to test the concept. Based on both visual inspection and quantitative analysis, the proposed sampling strategy showed better performance than sampling along the same phase-encoding direction in both multicontrast MR imaging and multiple PC-bSSFP imaging, regardless of sampling pattern (central, random) or datasets (public, retrospective and prospective in vivo). For the prospective in vivo applications, acceleration was performed by sampling along different phase-encoding directions at the time of acquisition with a conventional rectangular field of view, which demonstrated the advantage of the proposed sampling strategy in the real environment. Preliminary trials on compressed sensing (CS) also demonstrated improvement of CS with the proposed idea. Sampling along different phase-encoding directions across multiple acquisitions is advantageous for accelerating multiacquisition MRI, irrespective of sampling pattern or datasets, with further improvement through transfer learning.
Collapse
Affiliation(s)
- Ki Hwan Kim
- Department of Bio and Brain Engineering, Korea Advanced Institute of Science and Technology, Daejeon, South Korea
- Graduate School of Medical Science and Engineering, Korea Advanced Institute of Science and Technology, Daejeon, South Korea
| | - Sunghun Seo
- Department of Bio and Brain Engineering, Korea Advanced Institute of Science and Technology, Daejeon, South Korea
| | - Won-Joon Do
- Department of Bio and Brain Engineering, Korea Advanced Institute of Science and Technology, Daejeon, South Korea
| | - Huan Minh Luu
- Department of Bio and Brain Engineering, Korea Advanced Institute of Science and Technology, Daejeon, South Korea
| | - Sung-Hong Park
- Department of Bio and Brain Engineering, Korea Advanced Institute of Science and Technology, Daejeon, South Korea
- Graduate School of Medical Science and Engineering, Korea Advanced Institute of Science and Technology, Daejeon, South Korea
| |
Collapse
|
2
|
Gong K, Han PK, El Fakhri G, Ma C, Li Q. Arterial spin labeling MR image denoising and reconstruction using unsupervised deep learning. NMR IN BIOMEDICINE 2022; 35:e4224. [PMID: 31865615 PMCID: PMC7306418 DOI: 10.1002/nbm.4224] [Citation(s) in RCA: 9] [Impact Index Per Article: 3.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 03/06/2019] [Revised: 10/21/2019] [Accepted: 10/22/2019] [Indexed: 05/07/2023]
Abstract
Arterial spin labeling (ASL) imaging is a powerful magnetic resonance imaging technique that allows to quantitatively measure blood perfusion non-invasively, which has great potential for assessing tissue viability in various clinical settings. However, the clinical applications of ASL are currently limited by its low signal-to-noise ratio (SNR), limited spatial resolution, and long imaging time. In this work, we propose an unsupervised deep learning-based image denoising and reconstruction framework to improve the SNR and accelerate the imaging speed of high resolution ASL imaging. The unique feature of the proposed framework is that it does not require any prior training pairs but only the subject's own anatomical prior, such as T1-weighted images, as network input. The neural network was trained from scratch in the denoising or reconstruction process, with noisy images or sparely sampled k-space data as training labels. Performance of the proposed method was evaluated using in vivo experiment data obtained from 3 healthy subjects on a 3T MR scanner, using ASL images acquired with 44-min acquisition time as the ground truth. Both qualitative and quantitative analyses demonstrate the superior performance of the proposed txtc framework over the reference methods. In summary, our proposed unsupervised deep learning-based denoising and reconstruction framework can improve the image quality and accelerate the imaging speed of ASL imaging.
Collapse
Affiliation(s)
| | | | | | - Chao Ma
- Correspondence Chao Ma and Quanzheng Li, Gordon Center for Medical Imaging, Department of Radiology, Massachusetts General Hospital and Harvard Medical School, Boston, MA, USA, ,
| | - Quanzheng Li
- Correspondence Chao Ma and Quanzheng Li, Gordon Center for Medical Imaging, Department of Radiology, Massachusetts General Hospital and Harvard Medical School, Boston, MA, USA, ,
| |
Collapse
|
3
|
Liu X, Wang J, Lin S, Crozier S, Liu F. Optimizing multicontrast MRI reconstruction with shareable feature aggregation and selection. NMR IN BIOMEDICINE 2021; 34:e4540. [PMID: 33974306 DOI: 10.1002/nbm.4540] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 10/27/2020] [Revised: 04/05/2021] [Accepted: 04/25/2021] [Indexed: 06/12/2023]
Abstract
This paper proposes a new method for optimizing feature sharing in deep neural network-based, rapid, multicontrast magnetic resonance imaging (MC-MRI). Using the shareable information of MC images for accelerated MC-MRI reconstruction, current algorithms stack the MC images or features without optimizing the sharing protocols, leading to suboptimal reconstruction results. In this paper, we propose a novel feature aggregation and selection scheme in a deep neural network to better leverage the MC features and improve the reconstruction results. First, we propose to extract and use the shareable information by mapping the MC images into multiresolution feature maps with multilevel layers of the neural network. In this way, the extracted features capture complementary image properties, including local patterns from the shallow layers and semantic information from the deep layers. Then, an explicit selection module is designed to compile the extracted features optimally. That is, larger weights are learned to incorporate the constructive, shareable features; and smaller weights are assigned to the unshareable information. We conduct comparative studies on publicly available T2-weighted and T2-weighted fluid attenuated inversion recovery brain images, and the results show that the proposed network consistently outperforms existing algorithms. In addition, the proposed method can recover the images with high fidelity under 16 times acceleration. The ablation studies are conducted to evaluate the effectiveness of the proposed feature aggregation and selection mechanism. The results and the visualization of the weighted features show that the proposed method does effectively improve the usage of the useful features and suppress useless information, leading to overall enhanced reconstruction results. Additionally, the selection module can zero-out repeated and redundant features and improve network efficiency.
Collapse
Affiliation(s)
- Xinwen Liu
- School of Information Technology and Electrical Engineering, The University of Queensland, Brisbane, Australia
| | - Jing Wang
- School of Information and Communication Technology, Griffith University, Brisbane, Australia
| | - Suzhen Lin
- School of Data Science and Technology, North University of China, Taiyuan, China
- The Key Laboratory of Biomedical Imaging and Big Data Processing in Shanxi Province, Shanxi, China
| | - Stuart Crozier
- School of Information Technology and Electrical Engineering, The University of Queensland, Brisbane, Australia
| | - Feng Liu
- School of Information Technology and Electrical Engineering, The University of Queensland, Brisbane, Australia
| |
Collapse
|
4
|
Liu X, Wang J, Jin J, Li M, Tang F, Crozier S, Liu F. Deep unregistered multi-contrast MRI reconstruction. Magn Reson Imaging 2021; 81:33-41. [PMID: 34051290 DOI: 10.1016/j.mri.2021.05.005] [Citation(s) in RCA: 11] [Impact Index Per Article: 2.8] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/25/2021] [Revised: 04/18/2021] [Accepted: 05/23/2021] [Indexed: 11/18/2022]
Abstract
Multiple magnetic resonance images of different contrasts are normally acquired for clinical diagnosis. Recently, research has shown that the previously acquired multi-contrast (MC) images of the same patient can be used as anatomical prior to accelerating magnetic resonance imaging (MRI). However, current MC-MRI networks are based on the assumption that the images are perfectly registered, which is rarely the case in real-world applications. In this paper, we propose an end-to-end deep neural network to reconstruct highly accelerated images by exploiting the shareable information from potentially misaligned reference images of an arbitrary contrast. Specifically, a spatial transformation (ST) module is designed and integrated into the reconstruction network to align the pre-acquired reference images with the images to be reconstructed. The misalignment is further alleviated by maximizing the normalized cross-correlation (NCC) between the MC images. The visualization of feature maps demonstrates that the proposed method effectively reduces the misalignment between the images for shareable information extraction when applied to the publicly available brain datasets. Additionally, the experimental results on these datasets show the proposed network allows the robust exploitation of shareable information across the misaligned MC images, leading to improved reconstruction results.
Collapse
Affiliation(s)
- Xinwen Liu
- School of Information Technology and Electrical Engineering, the University of Queensland, Brisbane, Australia
| | | | - Jin Jin
- School of Information Technology and Electrical Engineering, the University of Queensland, Brisbane, Australia; Siemens Healthcare Pty. Ltd., Brisbane, Australia
| | - Mingyan Li
- School of Information Technology and Electrical Engineering, the University of Queensland, Brisbane, Australia
| | - Fangfang Tang
- School of Information Technology and Electrical Engineering, the University of Queensland, Brisbane, Australia
| | - Stuart Crozier
- School of Information Technology and Electrical Engineering, the University of Queensland, Brisbane, Australia
| | - Feng Liu
- School of Information Technology and Electrical Engineering, the University of Queensland, Brisbane, Australia.
| |
Collapse
|
5
|
Ryu K, Lee JH, Nam Y, Gho SM, Kim HS, Kim DH. Accelerated multicontrast reconstruction for synthetic MRI using joint parallel imaging and variable splitting networks. Med Phys 2021; 48:2939-2950. [PMID: 33733464 DOI: 10.1002/mp.14848] [Citation(s) in RCA: 6] [Impact Index Per Article: 1.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/26/2020] [Revised: 03/12/2021] [Accepted: 03/12/2021] [Indexed: 11/10/2022] Open
Abstract
PURPOSE Synthetic magnetic resonance imaging (MRI) requires the acquisition of multicontrast images to estimate quantitative parameter maps, such as T1 , T2 , and proton density (PD). The study aims to develop a multicontrast reconstruction method based on joint parallel imaging (JPI) and joint deep learning (JDL) to enable further acceleration of synthetic MRI. METHODS The JPI and JDL methods are extended and combined to improve reconstruction for better-quality, synthesized images. JPI is performed as a first step to estimate the missing k-space lines, and JDL is then performed to correct and refine the previous estimate with a trained neural network. For the JDL architecture, the original variable splitting network (VS-Net) is modified and extended to form a joint variable splitting network (JVS-Net) to apply to multicontrast reconstructions. The proposed method is designed and tested for multidynamic multiecho (MDME) images with Cartesian uniform under-sampling using acceleration factors between 4 and 8. RESULTS It is demonstrated that the normalized root-mean-square error (nRMSE) is lower and the structural similarity index measure (SSIM) values are higher with the proposed method compared to both the JPI and JDL methods individually. The method also demonstrates the potential to produce a set of synthesized contrast-weighted images that closely resemble those from the fully sampled acquisition without erroneous artifacts. CONCLUSION Combining JPI and JDL enables the reconstruction of highly accelerated synthetic MRIs.
Collapse
Affiliation(s)
- Kanghyun Ryu
- Department of Radiology, Stanford University, Stanford, CA, USA.,Department of Electrical and Electronic Engineering, Yonsei University, Seoul, Republic of Korea
| | - Jae-Hun Lee
- Department of Electrical and Electronic Engineering, Yonsei University, Seoul, Republic of Korea
| | - Yoonho Nam
- Department of Biomedical Engineering, Hankuk University of Foreign Studies, Yongin, Republic of Korea
| | - Sung-Min Gho
- MR Collaboration and Development, GE Healthcare, Seoul, Republic of Korea
| | - Ho-Sung Kim
- Department of Radiology and Research Institute of Radiology, University of Ulsan College of Medicine, Asan Medical Center, Seoul, Republic of Korea
| | - Dong-Hyun Kim
- Department of Electrical and Electronic Engineering, Yonsei University, Seoul, Republic of Korea
| |
Collapse
|
6
|
Zhang C, Klein S, Cristobal-Huerta A, Hernandez-Tamames JA, Poot DHJ. APIR4EMC: Autocalibrated parallel imaging reconstruction for extended multi-contrast imaging. Magn Reson Imaging 2021; 78:80-89. [PMID: 33592248 DOI: 10.1016/j.mri.2021.02.002] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/04/2020] [Revised: 01/11/2021] [Accepted: 02/03/2021] [Indexed: 11/26/2022]
Abstract
PURPOSE To improve image quality of multi-contrast imaging with the proposed Autocalibrated Parallel Imaging Reconstruction for Extended Multi-Contrast Imaging (APIR4EMC). METHODS APIR4EMC reconstructs multi-contrast images in an autocalibrated parallel imaging reconstruction framework by adding contrasts as virtual coils. Compensation of signal evolution along the echo train of different contrasts is performed to improve signal prediction for missing samples. As a proof of concept, we performed prospectively accelerated phantom and in-vivo brain acquisitions with T1, T1-fat saturated (Fatsat), T2, PD, and FLAIR contrasts. The k-space sampling patterns of these acquisitions were jointly optimized. Images were jointly reconstructed with the proposed APIR4EMC method as well as individually with GRAPPA. Root mean square error (RMSE) to fully sampled reference images and g-factor maps were computed for both methods in the phantom experiment. Visual evaluation was performed in the in-vivo experiment. RESULTS Compared to GRAPPA, APIR4EMC reduced artifacts and improved SNR of the reconstructed images in the phantom acquisitions. Quantitatively, APIR4EMC substantially reduced noise amplification (g-factor) as well as RMSE compared to GRAPPA. Signal evolution compensation reduced artifacts. In the in-vivo experiments, 1 mm3 isotropic 3D images with contrasts of T1, T1-Fatsat, T2, PD, and FLAIR were acquired in as little as 7.5 min with the acceleration factor of 9. Reconstruction quality was consistent with the phantom results. CONCLUSION Compared to single contrast reconstruction with GRAPPA, APIR4EMC reduces artifacts and noise amplification in accelerated multi-contrast imaging.
Collapse
Affiliation(s)
- Chaoping Zhang
- Department of Medical Informatics, Erasmus MC, Rotterdam, the Netherlands; Department of Radiology and Nuclear Medicine, Erasmus MC, Rotterdam, the Netherlands.
| | - Stefan Klein
- Department of Medical Informatics, Erasmus MC, Rotterdam, the Netherlands; Department of Radiology and Nuclear Medicine, Erasmus MC, Rotterdam, the Netherlands
| | | | | | - Dirk H J Poot
- Department of Medical Informatics, Erasmus MC, Rotterdam, the Netherlands; Department of Radiology and Nuclear Medicine, Erasmus MC, Rotterdam, the Netherlands
| |
Collapse
|
7
|
Yi Z, Liu Y, Zhao Y, Xiao L, Leong ATL, Feng Y, Chen F, Wu EX. Joint calibrationless reconstruction of highly undersampled multicontrast MR datasets using a low-rank Hankel tensor completion framework. Magn Reson Med 2021; 85:3256-3271. [PMID: 33533092 DOI: 10.1002/mrm.28674] [Citation(s) in RCA: 4] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/28/2020] [Revised: 12/18/2020] [Accepted: 12/18/2020] [Indexed: 11/05/2022]
Abstract
PURPOSE To jointly reconstruct highly undersampled multicontrast two-dimensional (2D) datasets through a low-rank Hankel tensor completion framework. METHODS A multicontrast Hankel tensor completion (MC-HTC) framework is proposed to exploit the shareable information in multicontrast datasets with respect to their highly correlated image structure, common spatial support, and shared coil sensitivity for joint reconstruction. This is achieved by first organizing multicontrast k-space datasets into a single block-wise Hankel tensor. Subsequent low-rank tensor approximation via higher-order singular value decomposition (HOSVD) uses the image structural correlation by considering different contrasts as virtual channels. Meanwhile, the HOSVD imposes common spatial support and shared coil sensitivity by treating data from different contrasts as from additional k-space kernels. The missing k-space data are then recovered by iteratively performing such low-rank approximation and enforcing data consistency. This joint reconstruction framework was evaluated using multicontrast multichannel 2D human brain datasets (T1 -weighted, T2 -weighted, fluid-attenuated inversion recovery, and T1 -weighted-inversion recovery) of identical image geometry with random and uniform undersampling schemes. RESULTS The proposed method offered high acceleration, exhibiting significantly less residual errors when compared with both single-contrast SAKE (simultaneous autocalibrating and k-space estimation) and multicontrast J-LORAKS (joint parallel-imaging-low-rank matrix modeling of local k-space neighborhoods) low-rank reconstruction. Furthermore, the MC-HTC framework was applied uniquely to Cartesian uniform undersampling by incorporating a novel complementary k-space sampling strategy where the phase-encoding direction among different contrasts is orthogonally alternated. CONCLUSION The proposed MC-HTC approach presents an effective tensor completion framework to jointly reconstruct highly undersampled multicontrast 2D datasets without coil-sensitivity calibration.
Collapse
Affiliation(s)
- Zheyuan Yi
- Laboratory of Biomedical Imaging and Signal Processing, The University of Hong Kong, Hong Kong SAR, People's Republic of China.,Department of Electrical and Electronic Engineering, The University of Hong Kong, Hong Kong SAR, People's Republic of China.,Department of Electrical and Electronic Engineering, Southern University of Science and Technology, Shenzhen, People's Republic of China
| | - Yilong Liu
- Laboratory of Biomedical Imaging and Signal Processing, The University of Hong Kong, Hong Kong SAR, People's Republic of China.,Department of Electrical and Electronic Engineering, The University of Hong Kong, Hong Kong SAR, People's Republic of China
| | - Yujiao Zhao
- Laboratory of Biomedical Imaging and Signal Processing, The University of Hong Kong, Hong Kong SAR, People's Republic of China.,Department of Electrical and Electronic Engineering, The University of Hong Kong, Hong Kong SAR, People's Republic of China
| | - Linfang Xiao
- Laboratory of Biomedical Imaging and Signal Processing, The University of Hong Kong, Hong Kong SAR, People's Republic of China.,Department of Electrical and Electronic Engineering, The University of Hong Kong, Hong Kong SAR, People's Republic of China
| | - Alex T L Leong
- Laboratory of Biomedical Imaging and Signal Processing, The University of Hong Kong, Hong Kong SAR, People's Republic of China.,Department of Electrical and Electronic Engineering, The University of Hong Kong, Hong Kong SAR, People's Republic of China
| | - Yanqiu Feng
- School of Biomedical Engineering, Southern Medical University, Guangzhou, Guangdong, People's Republic of China
| | - Fei Chen
- Department of Electrical and Electronic Engineering, Southern University of Science and Technology, Shenzhen, People's Republic of China
| | - Ed X Wu
- Laboratory of Biomedical Imaging and Signal Processing, The University of Hong Kong, Hong Kong SAR, People's Republic of China.,Department of Electrical and Electronic Engineering, The University of Hong Kong, Hong Kong SAR, People's Republic of China
| |
Collapse
|
8
|
Sveinsson B, Gold GE, Hargreaves BA, Yoon D. Utilizing shared information between gradient-spoiled and RF-spoiled steady-state MRI signals. Phys Med Biol 2021; 66:01NT03. [PMID: 33246317 DOI: 10.1088/1361-6560/abce8a] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/11/2022]
Abstract
This work presents an analytical relationship between gradient-spoiled and RF-spoiled steady-state signals. The two echoes acquired in double-echo in steady-state scans are shown to lie on a line in the signal plane, where the two axes represent the amplitudes of each echo. The location along the line depends on the amount of spoiling and the diffusivity. The line terminates in a point corresponding to an RF-spoiled signal. In addition to the main contribution of demonstrating this signal relationship, we also include the secondary contribution of preliminary results from an example application of the relationship, in the form of a heuristic denoising method when both types of scans are performed. This is investigated in simulations, phantom scans, and in vivo scans. For the signal model, the main topic of this study, simulations confirmed its accuracy and explored its dependency on signal parameters and image noise. For the secondary topic of its preliminary application to reduce noise, simulations demonstrated the denoising method giving a reduction in noise-induced standard deviation of about 30%. The relative effect of the method on the signals is shown to depend on the slope of the described line, which is demonstrated to be zero at the Ernst angle. The phantom scans show a similar effect as the simulations. In vivo scans showed a slightly lower average improvement of about 28%.
Collapse
Affiliation(s)
- Bragi Sveinsson
- Athinoula A. Martinos Center, Department of Radiology, Massachusetts General Hospital, Boston, MA, United States of America. Harvard Medical School, Boston, MA, United States of America
| | | | | | | |
Collapse
|
9
|
On the regularization of feature fusion and mapping for fast MR multi-contrast imaging via iterative networks. Magn Reson Imaging 2021; 77:159-168. [PMID: 33400936 DOI: 10.1016/j.mri.2020.12.019] [Citation(s) in RCA: 7] [Impact Index Per Article: 1.8] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/18/2020] [Revised: 12/01/2020] [Accepted: 12/29/2020] [Indexed: 01/23/2023]
Abstract
Multi-contrast (MC) Magnetic Resonance Imaging (MRI) of the same patient usually requires long scanning times, despite the images sharing redundant information. In this work, we propose a new iterative network that utilizes the sharable information among MC images for MRI acceleration. The proposed network has reinforced data fidelity control and anatomy guidance through an iterative optimization procedure of Gradient Descent, leading to reduced uncertainties and improved reconstruction results. Through a convolutional network, the new method incorporates a learnable regularization unit that is capable of extracting, fusing, and mapping shareable information among different contrasts. Specifically, a dilated inception block is proposed to promote multi-scale feature extractions and increase the receptive field diversity for contextual information incorporation. Lastly, an optimal MC information feeding protocol is built through the design of a complementary feature extractor block. Comprehensive experiments demonstrated the superiority of the proposed network, both qualitatively and quantitatively.
Collapse
|
10
|
Zibetti MVW, Helou ES, Sharafi A, Regatte RR. Fast multicomponent 3D-T 1ρ relaxometry. NMR IN BIOMEDICINE 2020; 33:e4318. [PMID: 32359000 PMCID: PMC7606711 DOI: 10.1002/nbm.4318] [Citation(s) in RCA: 4] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 07/03/2019] [Revised: 03/10/2020] [Accepted: 04/05/2020] [Indexed: 05/06/2023]
Abstract
NMR relaxometry can provide information about the relaxation of the magnetization in different tissues, increasing our understanding of molecular dynamics and biochemical composition in biological systems. In general, tissues have complex and heterogeneous structures composed of multiple pools. As a result, bulk magnetization returns to its original state with different relaxation times, in a multicomponent relaxation. Recovering the distribution of relaxation times in each voxel is a difficult inverse problem; it is usually unstable and requires long acquisition time, especially on clinical scanners. MRI can also be viewed as an inverse problem, especially when compressed sensing (CS) is used. The solution of these two inverse problems, CS and relaxometry, can be obtained very efficiently in a synergistically combined manner, leading to a more stable multicomponent relaxometry obtained with short scan times. In this paper, we will discuss the details of this technique from the viewpoint of inverse problems.
Collapse
Affiliation(s)
- Marcelo V W Zibetti
- Center for Biomedical Imaging, Department of Radiology, New York University School of Medicine, New York, NY, US
| | - Elias S Helou
- Institute of Mathematical Sciences and Computation, University of São Paulo, São Carlos, SP, Brazil
| | - Azadeh Sharafi
- Center for Biomedical Imaging, Department of Radiology, New York University School of Medicine, New York, NY, US
| | - Ravinder R Regatte
- Center for Biomedical Imaging, Department of Radiology, New York University School of Medicine, New York, NY, US
| |
Collapse
|
11
|
Kim D, Wisnowski JL, Nguyen CT, Haldar JP. Multidimensional correlation spectroscopic imaging of exponential decays: From theoretical principles to in vivo human applications. NMR IN BIOMEDICINE 2020; 33:e4244. [PMID: 31909534 PMCID: PMC7338241 DOI: 10.1002/nbm.4244] [Citation(s) in RCA: 9] [Impact Index Per Article: 1.8] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 05/09/2019] [Revised: 10/09/2019] [Accepted: 11/27/2019] [Indexed: 05/02/2023]
Abstract
Multiexponential modeling of relaxation or diffusion MR signal decays is a popular approach for estimating and spatially mapping different microstructural tissue compartments. While this approach can be quite powerful, it is also limited by the fact that one-dimensional multiexponential modeling is an ill-posed inverse problem with substantial ambiguities. In this article, we present an overview of a recent multidimensional correlation spectroscopic imaging approach to this problem. This approach helps to alleviate ill-posedness by making advantageous use of multidimensional contrast encoding (e.g., 2D diffusion-relaxation encoding or 2D relaxation-relaxation encoding) combined with a regularized spatial-spectral estimation procedure. Theoretical calculations, simulations, and experimental results are used to illustrate the benefits of this approach relative to classical methods. In addition, we demonstrate an initial proof-of-principle application of this kind of approach to in vivo human MRI experiments.
Collapse
Affiliation(s)
- Daeun Kim
- Ming Hsieh Department of Electrical and Computer Engineering, University of Southern California, CA, USA
- Signal and Image Processing Institute, University of Southern California, CA, USA
- Correspondence Daeun Kim,
| | - Jessica L. Wisnowski
- Radiology, Children’s Hospital Los Angeles, CA, USA
- Pediatrics, Children’s Hospital Los Angeles, CA, USA
| | - Christopher T. Nguyen
- Harvard Medical School and Cardiovascular Research Center, Massachusetts General Hospital, MA, USA
- Martinos Center for Biomedical Imaging, Radiology, Massachusetts General Hospital, MA, USA
- Biomedical Imaging Research Institute, Cedars-Sinai Medical Center, CA, USA
| | - Justin P. Haldar
- Ming Hsieh Department of Electrical and Computer Engineering, University of Southern California, CA, USA
- Signal and Image Processing Institute, University of Southern California, CA, USA
| |
Collapse
|
12
|
Lyu Q, Shan H, Steber C, Helis C, Whitlow CT, Chan M, Wang G. Multi-Contrast Super-Resolution MRI Through a Progressive Network. IEEE TRANSACTIONS ON MEDICAL IMAGING 2020; 39:2738-2749. [PMID: 32086201 PMCID: PMC7673259 DOI: 10.1109/tmi.2020.2974858] [Citation(s) in RCA: 57] [Impact Index Per Article: 11.4] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 05/25/2023]
Abstract
Magnetic resonance imaging (MRI) is widely used for screening, diagnosis, image-guided therapy, and scientific research. A significant advantage of MRI over other imaging modalities such as computed tomography (CT) and nuclear imaging is that it clearly shows soft tissues in multi-contrasts. Compared with other medical image super-resolution methods that are in a single contrast, multi-contrast super-resolution studies can synergize multiple contrast images to achieve better super-resolution results. In this paper, we propose a one-level non-progressive neural network for low up-sampling multi-contrast super-resolution and a two-level progressive network for high up-sampling multi-contrast super-resolution. The proposed networks integrate multi-contrast information in a high-level feature space and optimize the imaging performance by minimizing a composite loss function, which includes mean-squared-error, adversarial loss, perceptual loss, and textural loss. Our experimental results demonstrate that 1) the proposed networks can produce MRI super-resolution images with good image quality and outperform other multi-contrast super-resolution methods in terms of structural similarity and peak signal-to-noise ratio; 2) combining multi-contrast information in a high-level feature space leads to a significantly improved result than a combination in the low-level pixel space; and 3) the progressive network produces a better super-resolution image quality than the non-progressive network, even if the original low-resolution images were highly down-sampled.
Collapse
Affiliation(s)
- Qing Lyu
- Department of Biomedical Engineering, Rensselaer Polytechnic Institute, Troy, NY, 12180, USA
| | | | - Cole Steber
- Department of Radiation Oncology, Wake Forest School of Medicine, Winston-Salem, NC, 27101, USA
| | - Corbin Helis
- Department of Radiation Oncology, Wake Forest School of Medicine, Winston-Salem, NC, 27101, USA
| | - Christopher T. Whitlow
- Department of Radiology, Department of Biomedical Engineering, and Department of Biostatistics and Data Science, Wake Forest School of Medicine, Winston-Salem, NC, 27157, USA
| | | | | |
Collapse
|
13
|
Polak D, Cauley S, Bilgic B, Gong E, Bachert P, Adalsteinsson E, Setsompop K. Joint multi-contrast variational network reconstruction (jVN) with application to rapid 2D and 3D imaging. Magn Reson Med 2020; 84:1456-1469. [PMID: 32129529 PMCID: PMC7539238 DOI: 10.1002/mrm.28219] [Citation(s) in RCA: 19] [Impact Index Per Article: 3.8] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/30/2019] [Revised: 01/20/2020] [Accepted: 01/29/2020] [Indexed: 12/14/2022]
Abstract
PURPOSE To improve the image quality of highly accelerated multi-channel MRI data by learning a joint variational network that reconstructs multiple clinical contrasts jointly. METHODS Data from our multi-contrast acquisition were embedded into the variational network architecture where shared anatomical information is exchanged by mixing the input contrasts. Complementary k-space sampling across imaging contrasts and Bunch-Phase/Wave-Encoding were used for data acquisition to improve the reconstruction at high accelerations. At 3T, our joint variational network approach across T1w, T2w and T2-FLAIR-weighted brain scans was tested for retrospective under-sampling at R = 6 (2D) and R = 4 × 4 (3D) acceleration. Prospective acceleration was also performed for 3D data where the combined acquisition time for whole brain coverage at 1 mm isotropic resolution across three contrasts was less than 3 min. RESULTS Across all test datasets, our joint multi-contrast network better preserved fine anatomical details with reduced image-blurring when compared to the corresponding single-contrast reconstructions. Improvement in image quality was also obtained through complementary k-space sampling and Bunch-Phase/Wave-Encoding where the synergistic combination yielded the overall best performance as evidenced by exemplary slices and quantitative error metrics. CONCLUSION By leveraging shared anatomical structures across the jointly reconstructed scans, our joint multi-contrast approach learnt more efficient regularizers, which helped to retain natural image appearance and avoid over-smoothing. When synergistically combined with advanced encoding techniques, the performance was further improved, enabling up to R = 16-fold acceleration with good image quality. This should help pave the way to very rapid high-resolution brain exams.
Collapse
Affiliation(s)
- Daniel Polak
- Department of Physics and Astronomy, Heidelberg University, Heidelberg, Germany
- Department of Radiology, A. A. Martinos Center for Biomedical Imaging, Massachusetts General Hospital, Charlestown, MA, USA
- Siemens Healthcare GmbH, Erlangen, Germany
| | - Stephen Cauley
- Department of Radiology, A. A. Martinos Center for Biomedical Imaging, Massachusetts General Hospital, Charlestown, MA, USA
- Harvard Medical School, Boston, MA, USA
- Harvard-MIT Health Sciences and Technology, Massachusetts Institute of Technology, Cambridge, MA, USA
| | - Berkin Bilgic
- Department of Radiology, A. A. Martinos Center for Biomedical Imaging, Massachusetts General Hospital, Charlestown, MA, USA
- Harvard Medical School, Boston, MA, USA
- Harvard-MIT Health Sciences and Technology, Massachusetts Institute of Technology, Cambridge, MA, USA
| | | | - Peter Bachert
- Department of Physics and Astronomy, Heidelberg University, Heidelberg, Germany
- Medical Physics in Radiology, German Cancer Research Center (DKFZ), Heidelberg, Germany
| | - Elfar Adalsteinsson
- Department of Electrical Engineering and Computer Science, Massachusetts Institute of Technology, Cambridge, MA, USA
| | - Kawin Setsompop
- Department of Radiology, A. A. Martinos Center for Biomedical Imaging, Massachusetts General Hospital, Charlestown, MA, USA
- Harvard Medical School, Boston, MA, USA
- Harvard-MIT Health Sciences and Technology, Massachusetts Institute of Technology, Cambridge, MA, USA
| |
Collapse
|
14
|
Sudarshan VP, Egan GF, Chen Z, Awate SP. Joint PET-MRI image reconstruction using a patch-based joint-dictionary prior. Med Image Anal 2020; 62:101669. [DOI: 10.1016/j.media.2020.101669] [Citation(s) in RCA: 15] [Impact Index Per Article: 3.0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/30/2019] [Revised: 02/20/2020] [Accepted: 02/21/2020] [Indexed: 12/18/2022]
|
15
|
Kopanoglu E, Güngör A, Kilic T, Saritas EU, Oguz KK, Çukur T, Güven HE. Simultaneous use of individual and joint regularization terms in compressive sensing: Joint reconstruction of multi-channel multi-contrast MRI acquisitions. NMR IN BIOMEDICINE 2020; 33:e4247. [PMID: 31970849 DOI: 10.1002/nbm.4247] [Citation(s) in RCA: 8] [Impact Index Per Article: 1.6] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 05/02/2019] [Revised: 11/18/2019] [Accepted: 11/22/2019] [Indexed: 06/10/2023]
Abstract
Multi-contrast images are commonly acquired together to maximize complementary diagnostic information, albeit at the expense of longer scan times. A time-efficient strategy to acquire high-quality multi-contrast images is to accelerate individual sequences and then reconstruct undersampled data with joint regularization terms that leverage common information across contrasts. However, these terms can cause features that are unique to a subset of contrasts to leak into the other contrasts. Such leakage-of-features may appear as artificial tissues, thereby misleading diagnosis. The goal of this study is to develop a compressive sensing method for multi-channel multi-contrast magnetic resonance imaging (MRI) that optimally utilizes shared information while preventing feature leakage. Joint regularization terms group sparsity and colour total variation are used to exploit common features across images while individual sparsity and total variation are also used to prevent leakage of distinct features across contrasts. The multi-channel multi-contrast reconstruction problem is solved via a fast algorithm based on Alternating Direction Method of Multipliers. The proposed method is compared against using only individual and only joint regularization terms in reconstruction. Comparisons were performed on single-channel simulated and multi-channel in-vivo datasets in terms of reconstruction quality and neuroradiologist reader scores. The proposed method demonstrates rapid convergence and improved image quality for both simulated and in-vivo datasets. Furthermore, while reconstructions that solely use joint regularization terms are prone to leakage-of-features, the proposed method reliably avoids leakage via simultaneous use of joint and individual terms, thereby holding great promise for clinical use.
Collapse
Affiliation(s)
- Emre Kopanoglu
- Cardiff University, Brain Research Imaging Centre (CUBRIC), School of Psychology, Cardiff University, Cardiff, UK
- ASELSAN Research Center, Ankara, Turkey
| | - Alper Güngör
- ASELSAN Research Center, Ankara, Turkey
- Department of Electrical and Electronics Engineering, Bilkent University, Ankara, Turkey
- National Magnetic Resonance Research Center (UMRAM), Bilkent University, Ankara, Turkey
| | - Toygan Kilic
- Department of Electrical and Electronics Engineering, Bilkent University, Ankara, Turkey
- National Magnetic Resonance Research Center (UMRAM), Bilkent University, Ankara, Turkey
| | - Emine Ulku Saritas
- Department of Electrical and Electronics Engineering, Bilkent University, Ankara, Turkey
- National Magnetic Resonance Research Center (UMRAM), Bilkent University, Ankara, Turkey
- Neuroscience Program, Sabuncu Brain Research Center, Bilkent University, Ankara, Turkey
| | - Kader K Oguz
- National Magnetic Resonance Research Center (UMRAM), Bilkent University, Ankara, Turkey
- Department of Radiology, Hacettepe University, Ankara, Turkey
| | - Tolga Çukur
- Department of Electrical and Electronics Engineering, Bilkent University, Ankara, Turkey
- National Magnetic Resonance Research Center (UMRAM), Bilkent University, Ankara, Turkey
- Neuroscience Program, Sabuncu Brain Research Center, Bilkent University, Ankara, Turkey
| | | |
Collapse
|
16
|
Shahdloo M, Ilicak E, Tofighi M, Saritas EU, Cetin AE, Cukur T. Projection onto Epigraph Sets for Rapid Self-Tuning Compressed Sensing MRI. IEEE TRANSACTIONS ON MEDICAL IMAGING 2019; 38:1677-1689. [PMID: 30530317 DOI: 10.1109/tmi.2018.2885599] [Citation(s) in RCA: 7] [Impact Index Per Article: 1.2] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 06/09/2023]
Abstract
The compressed sensing (CS) framework leverages the sparsity of MR images to reconstruct from the undersampled acquisitions. CS reconstructions involve one or more regularization parameters that weigh sparsity in transform domains against fidelity to acquired data. While parameter selection is critical for reconstruction quality, the optimal parameters are subject and dataset specific. Thus, commonly practiced heuristic parameter selection generalizes poorly to independent datasets. Recent studies have proposed to tune parameters by estimating the risk of removing significant image coefficients. Line searches are performed across the parameter space to identify the parameter value that minimizes this risk. Although effective, these line searches yield prolonged reconstruction times. Here, we propose a new self-tuning CS method that uses computationally efficient projections onto epigraph sets of the l1 and total-variation norms to simultaneously achieve parameter selection and regularization. In vivo demonstrations are provided for balanced steady-state free precession, time-of-flight, and T1-weighted imaging. The proposed method achieves an order of magnitude improvement in computational efficiency over line-search methods while maintaining near-optimal parameter selection.
Collapse
|
17
|
Bustin A, Lima da Cruz G, Jaubert O, Lopez K, Botnar RM, Prieto C. High-dimensionality undersampled patch-based reconstruction (HD-PROST) for accelerated multi-contrast MRI. Magn Reson Med 2019; 81:3705-3719. [PMID: 30834594 PMCID: PMC6646908 DOI: 10.1002/mrm.27694] [Citation(s) in RCA: 67] [Impact Index Per Article: 11.2] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/28/2018] [Revised: 01/23/2019] [Accepted: 01/23/2019] [Indexed: 12/14/2022]
Abstract
PURPOSE To develop a new high-dimensionality undersampled patch-based reconstruction (HD-PROST) for highly accelerated 2D and 3D multi-contrast MRI. METHODS HD-PROST jointly reconstructs multi-contrast MR images by exploiting the highly redundant information, on a local and non-local scale, and the strong correlation shared between the multiple contrast images. This is achieved by enforcing multi-dimensional low-rank in the undersampled images. 2D magnetic resonance fingerprinting (MRF) phantom and in vivo brain acquisitions were performed to evaluate the performance of HD-PROST for highly accelerated simultaneous T1 and T2 mapping. Additional in vivo experiments for reconstructing multiple undersampled 3D magnetization transfer (MT)-weighted images were conducted to illustrate the impact of HD-PROST for high-resolution multi-contrast 3D imaging. RESULTS In the 2D MRF phantom study, HD-PROST provided accurate and precise estimation of the T1 and T2 values in comparison to gold standard spin echo acquisitions. HD-PROST achieved good quality maps for the in vivo 2D MRF experiments in comparison to conventional low-rank inversion reconstruction. T1 and T2 values of white matter and gray matter were in good agreement with those reported in the literature for MRF acquisitions with reduced number of time point images (500 time point images, ~2.5 s scan time). For in vivo MT-weighted 3D acquisitions (6 different contrasts), HD-PROST achieved similar image quality than the fully sampled reference image for an undersampling factor of 6.5-fold. CONCLUSION HD-PROST enables multi-contrast 2D and 3D MR images in a short acquisition time without compromising image quality. Ultimately, this technique may increase the potential of conventional parameter mapping.
Collapse
Affiliation(s)
- Aurélien Bustin
- Department of Biomedical Engineering, School of Imaging Sciences & Biomedical EngineeringKing’s College London, King’s Health PartnersLondonUnited Kingdom
| | - Gastão Lima da Cruz
- Department of Biomedical Engineering, School of Imaging Sciences & Biomedical EngineeringKing’s College London, King’s Health PartnersLondonUnited Kingdom
| | - Olivier Jaubert
- Department of Biomedical Engineering, School of Imaging Sciences & Biomedical EngineeringKing’s College London, King’s Health PartnersLondonUnited Kingdom
| | - Karina Lopez
- Department of Biomedical Engineering, School of Imaging Sciences & Biomedical EngineeringKing’s College London, King’s Health PartnersLondonUnited Kingdom
| | - René M. Botnar
- Department of Biomedical Engineering, School of Imaging Sciences & Biomedical EngineeringKing’s College London, King’s Health PartnersLondonUnited Kingdom
- Escuela de IngenieríaPontificia Universidad Católica de ChileSantiagoChile
| | - Claudia Prieto
- Department of Biomedical Engineering, School of Imaging Sciences & Biomedical EngineeringKing’s College London, King’s Health PartnersLondonUnited Kingdom
- Escuela de IngenieríaPontificia Universidad Católica de ChileSantiagoChile
| |
Collapse
|
18
|
Bilgic B, Kim TH, Liao C, Manhard MK, Wald LL, Haldar JP, Setsompop K. Improving parallel imaging by jointly reconstructing multi-contrast data. Magn Reson Med 2018; 80:619-632. [PMID: 29322551 PMCID: PMC5910232 DOI: 10.1002/mrm.27076] [Citation(s) in RCA: 54] [Impact Index Per Article: 7.7] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/16/2017] [Revised: 12/10/2017] [Accepted: 12/15/2017] [Indexed: 12/14/2022]
Abstract
PURPOSE To develop parallel imaging techniques that simultaneously exploit coil sensitivity encoding, image phase prior information, similarities across multiple images, and complementary k-space sampling for highly accelerated data acquisition. METHODS We introduce joint virtual coil (JVC)-generalized autocalibrating partially parallel acquisitions (GRAPPA) to jointly reconstruct data acquired with different contrast preparations, and show its application in 2D, 3D, and simultaneous multi-slice (SMS) acquisitions. We extend the joint parallel imaging concept to exploit limited support and smooth phase constraints through Joint (J-) LORAKS formulation. J-LORAKS allows joint parallel imaging from limited autocalibration signal region, as well as permitting partial Fourier sampling and calibrationless reconstruction. RESULTS We demonstrate highly accelerated 2D balanced steady-state free precession with phase cycling, SMS multi-echo spin echo, 3D multi-echo magnetization-prepared rapid gradient echo, and multi-echo gradient recalled echo acquisitions in vivo. Compared to conventional GRAPPA, proposed joint acquisition/reconstruction techniques provide more than 2-fold reduction in reconstruction error. CONCLUSION JVC-GRAPPA takes advantage of additional spatial encoding from phase information and image similarity, and employs different sampling patterns across acquisitions. J-LORAKS achieves a more parsimonious low-rank representation of local k-space by considering multiple images as additional coils. Both approaches provide dramatic improvement in artifact and noise mitigation over conventional single-contrast parallel imaging reconstruction. Magn Reson Med 80:619-632, 2018. © 2018 International Society for Magnetic Resonance in Medicine.
Collapse
Affiliation(s)
- Berkin Bilgic
- Athinoula A. Martinos Center for Biomedical Imaging, Charlestown, MA, USA
- Department of Radiology, Harvard Medical School, Boston, MA, USA
| | - Tae Hyung Kim
- Department of Electrical Engineering, University of Southern California, Los Angeles, CA, USA
- Signal and Image Processing Institute, University of Southern California, Los Angeles, CA, USA
| | - Congyu Liao
- Athinoula A. Martinos Center for Biomedical Imaging, Charlestown, MA, USA
- Center for Brain Imaging Science and Technology, Key Laboratory for Biomedical Engineering of Ministry of Education, College of Biomedical Engineering & Instrument Science, Zhejiang University, Hangzhou, Zhejiang, China
| | - Mary Kate Manhard
- Athinoula A. Martinos Center for Biomedical Imaging, Charlestown, MA, USA
- Department of Radiology, Harvard Medical School, Boston, MA, USA
| | - Lawrence L. Wald
- Athinoula A. Martinos Center for Biomedical Imaging, Charlestown, MA, USA
- Department of Radiology, Harvard Medical School, Boston, MA, USA
- Harvard-MIT Health Sciences and Technology, MIT, Cambridge, MA, USA
| | - Justin P. Haldar
- Department of Electrical Engineering, University of Southern California, Los Angeles, CA, USA
- Signal and Image Processing Institute, University of Southern California, Los Angeles, CA, USA
| | - Kawin Setsompop
- Athinoula A. Martinos Center for Biomedical Imaging, Charlestown, MA, USA
- Department of Radiology, Harvard Medical School, Boston, MA, USA
- Harvard-MIT Health Sciences and Technology, MIT, Cambridge, MA, USA
| |
Collapse
|
19
|
Kwon K, Kim D, Park H. A parallel MR imaging method using multilayer perceptron. Med Phys 2017; 44:6209-6224. [DOI: 10.1002/mp.12600] [Citation(s) in RCA: 89] [Impact Index Per Article: 11.1] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/01/2017] [Revised: 09/17/2017] [Accepted: 09/18/2017] [Indexed: 11/08/2022] Open
Affiliation(s)
- Kinam Kwon
- Department of Electrical Engineering; Korea Advanced Institute of Science and Technology (KAIST); Daejeon South Korea
| | - Dongchan Kim
- College of Medicine; Gachon University; Incheon South Korea
| | - HyunWook Park
- Department of Electrical Engineering; Korea Advanced Institute of Science and Technology (KAIST); Daejeon South Korea
| |
Collapse
|
20
|
Coolen BF, Calcagno C, van Ooij P, Fayad ZA, Strijkers GJ, Nederveen AJ. Vessel wall characterization using quantitative MRI: what's in a number? MAGNETIC RESONANCE MATERIALS IN PHYSICS BIOLOGY AND MEDICINE 2017; 31:201-222. [PMID: 28808823 PMCID: PMC5813061 DOI: 10.1007/s10334-017-0644-x] [Citation(s) in RCA: 30] [Impact Index Per Article: 3.8] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 03/07/2017] [Revised: 07/04/2017] [Accepted: 07/18/2017] [Indexed: 12/15/2022]
Abstract
The past decade has witnessed the rapid development of new MRI technology for vessel wall imaging. Today, with advances in MRI hardware and pulse sequences, quantitative MRI of the vessel wall represents a real alternative to conventional qualitative imaging, which is hindered by significant intra- and inter-observer variability. Quantitative MRI can measure several important morphological and functional characteristics of the vessel wall. This review provides a detailed introduction to novel quantitative MRI methods for measuring vessel wall dimensions, plaque composition and permeability, endothelial shear stress and wall stiffness. Together, these methods show the versatility of non-invasive quantitative MRI for probing vascular disease at several stages. These quantitative MRI biomarkers can play an important role in the context of both treatment response monitoring and risk prediction. Given the rapid developments in scan acceleration techniques and novel image reconstruction, we foresee the possibility of integrating the acquisition of multiple quantitative vessel wall parameters within a single scan session.
Collapse
Affiliation(s)
- Bram F Coolen
- Department of Biomedical Engineering and Physics, Academic Medical Center, PO BOX 22660, 1100 DD, Amsterdam, The Netherlands. .,Department of Radiology, Academic Medical Center, Amsterdam, The Netherlands.
| | - Claudia Calcagno
- Translational and Molecular Imaging Institute, Icahn School of Medicine at Mount Sinai, New York, NY, USA.,Department of Radiology, Icahn School of Medicine at Mount Sinai, New York, NY, USA
| | - Pim van Ooij
- Department of Radiology, Academic Medical Center, Amsterdam, The Netherlands
| | - Zahi A Fayad
- Translational and Molecular Imaging Institute, Icahn School of Medicine at Mount Sinai, New York, NY, USA.,Department of Radiology, Icahn School of Medicine at Mount Sinai, New York, NY, USA
| | - Gustav J Strijkers
- Department of Biomedical Engineering and Physics, Academic Medical Center, PO BOX 22660, 1100 DD, Amsterdam, The Netherlands
| | - Aart J Nederveen
- Department of Radiology, Academic Medical Center, Amsterdam, The Netherlands
| |
Collapse
|
21
|
Knoll F, Holler M, Koesters T, Otazo R, Bredies K, Sodickson DK. Joint MR-PET Reconstruction Using a Multi-Channel Image Regularizer. IEEE TRANSACTIONS ON MEDICAL IMAGING 2017; 36:1-16. [PMID: 28055827 PMCID: PMC5218518 DOI: 10.1109/tmi.2016.2564989] [Citation(s) in RCA: 54] [Impact Index Per Article: 6.8] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 05/20/2023]
Abstract
While current state of the art MR-PET scanners enable simultaneous MR and PET measurements, the acquired data sets are still usually reconstructed separately. We propose a new multi-modality reconstruction framework using second order Total Generalized Variation (TGV) as a dedicated multi-channel regularization functional that jointly reconstructs images from both modalities. In this way, information about the underlying anatomy is shared during the image reconstruction process while unique differences are preserved. Results from numerical simulations and in-vivo experiments using a range of accelerated MR acquisitions and different MR image contrasts demonstrate improved PET image quality, resolution, and quantitative accuracy.
Collapse
Affiliation(s)
- Florian Knoll
- Bernard and Irene Schwartz Center for Biomedical Imaging, and the Center for Advanced Imaging Innovation and Research (CAIR), in the Department of Radiology at NYU School of Medicine, New York, NY, United States
| | - Martin Holler
- Institute of Mathematics and Scientific Computing, University of Graz, Graz, Austria. The Institute of Mathematics and Scientific Computing is a member of NAWI Graz (www.nawigraz.at) and BioTechMed Graz (www.biotechmed.at)
| | - Thomas Koesters
- Bernard and Irene Schwartz Center for Biomedical Imaging, and the Center for Advanced Imaging Innovation and Research (CAIR), in the Department of Radiology at NYU School of Medicine, New York, NY, United States
| | - Ricardo Otazo
- Bernard and Irene Schwartz Center for Biomedical Imaging, and the Center for Advanced Imaging Innovation and Research (CAIR), in the Department of Radiology at NYU School of Medicine, New York, NY, United States
| | - Kristian Bredies
- Institute of Mathematics and Scientific Computing, University of Graz, Graz, Austria. The Institute of Mathematics and Scientific Computing is a member of NAWI Graz (www.nawigraz.at) and BioTechMed Graz (www.biotechmed.at)
| | - Daniel K Sodickson
- Bernard and Irene Schwartz Center for Biomedical Imaging, and the Center for Advanced Imaging Innovation and Research (CAIR), in the Department of Radiology at NYU School of Medicine, New York, NY, United States
| |
Collapse
|
22
|
Chatnuntawech I, Martin A, Bilgic B, Setsompop K, Adalsteinsson E, Schiavi E. Vectorial total generalized variation for accelerated multi-channel multi-contrast MRI. Magn Reson Imaging 2016; 34:1161-70. [DOI: 10.1016/j.mri.2016.05.014] [Citation(s) in RCA: 17] [Impact Index Per Article: 1.9] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/07/2015] [Accepted: 05/30/2016] [Indexed: 11/24/2022]
|
23
|
Alexander MD, Yuan C, Rutman A, Tirschwell DL, Palagallo G, Gandhi D, Sekhar LN, Mossa-Basha M. High-resolution intracranial vessel wall imaging: imaging beyond the lumen. J Neurol Neurosurg Psychiatry 2016; 87:589-97. [PMID: 26746187 PMCID: PMC5504758 DOI: 10.1136/jnnp-2015-312020] [Citation(s) in RCA: 94] [Impact Index Per Article: 10.4] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 08/13/2015] [Accepted: 11/23/2015] [Indexed: 01/21/2023]
Abstract
Accurate and timely diagnosis of intracranial vasculopathies is important due to significant risk of morbidity with delayed and/or incorrect diagnosis both from the disease process as well as inappropriate therapies. Conventional vascular imaging techniques for analysis of intracranial vascular disease provide limited information since they only identify changes to the vessel lumen. New advanced MR intracranial vessel wall imaging (IVW) techniques can allow direct characterisation of the vessel wall. These techniques can advance diagnostic accuracy and may potentially improve patient outcomes by better guided treatment decisions in comparison to previously available invasive and non-invasive techniques. While neuroradiological expertise is invaluable in accurate examination interpretation, clinician familiarity with the application and findings of the various vasculopathies on IVW can help guide diagnostic and therapeutic decision-making. This review article provides a brief overview of the technical aspects of IVW and discusses the IVW findings of various intracranial vasculopathies, differentiating characteristics and indications for when this technique can be beneficial in patient management.
Collapse
Affiliation(s)
| | - Chun Yuan
- Department of Radiology, University of Washington, Seattle, Washington, USA
| | - Aaron Rutman
- Department of Radiology, University of Washington, Seattle, Washington, USA
| | - David L Tirschwell
- Department of Neurology, University of Washington, Seattle, Washington, USA
| | - Gerald Palagallo
- Department of Radiology, University of Washington, Seattle, Washington, USA
| | - Dheeraj Gandhi
- Department of Radiology, Neurology and Neurosurgery, University of Maryland, Baltimore, Maryland, USA
| | - Laligam N Sekhar
- Department of Neurological Surgery, University of Washington, Seattle, Washington, USA
| | - Mahmud Mossa-Basha
- Department of Radiology, University of Washington, Seattle, Washington, USA
| |
Collapse
|
24
|
Ilicak E, Cetin S, Bulut E, Oguz KK, Saritas EU, Unal G, Çukur T. Targeted vessel reconstruction in non-contrast-enhanced steady-state free precession angiography. NMR IN BIOMEDICINE 2016; 29:532-544. [PMID: 26854004 DOI: 10.1002/nbm.3497] [Citation(s) in RCA: 6] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 07/15/2015] [Revised: 01/07/2016] [Accepted: 01/08/2016] [Indexed: 06/05/2023]
Abstract
Image quality in non-contrast-enhanced (NCE) angiograms is often limited by scan time constraints. An effective solution is to undersample angiographic acquisitions and to recover vessel images with penalized reconstructions. However, conventional methods leverage penalty terms with uniform spatial weighting, which typically yield insufficient suppression of aliasing interference and suboptimal blood/background contrast. Here we propose a two-stage strategy where a tractographic segmentation is employed to auto-extract vasculature maps from undersampled data. These maps are then used to incur spatially adaptive sparsity penalties on vascular and background regions. In vivo steady-state free precession angiograms were acquired in the hand, lower leg and foot. Compared with regular non-adaptive compressed sensing (CS) reconstructions (CSlow ), the proposed strategy improves blood/background contrast by 71.3 ± 28.9% in the hand (mean ± s.d. across acceleration factors 1-8), 30.6 ± 11.3% in the lower leg and 28.1 ± 7.0% in the foot (signed-rank test, P < 0.05 at each acceleration). The proposed targeted reconstruction can relax trade-offs between image contrast, resolution and scan efficiency without compromising vessel depiction.
Collapse
Affiliation(s)
- Efe Ilicak
- Department of Electrical and Electronics Engineering and the National Magnetic Resonance Research Center, Bilkent University, Ankara, Turkey
| | - Suheyla Cetin
- Faculty of Engineering and Natural Sciences, Sabanci University, Istanbul, Turkey
| | - Elif Bulut
- Hacettepe University Faculty of Medicine, Ankara, Turkey
| | | | - Emine Ulku Saritas
- Department of Electrical and Electronics Engineering and the National Magnetic Resonance Research Center, Bilkent University, Ankara, Turkey
| | - Gozde Unal
- Department of Computer Engineering, Istanbul Technical University, Istanbul, Turkey
| | - Tolga Çukur
- Department of Electrical and Electronics Engineering and the National Magnetic Resonance Research Center, Bilkent University, Ankara, Turkey
| |
Collapse
|
25
|
Ongie G, Jacob M. Off-the-Grid Recovery of Piecewise Constant Images from Few Fourier Samples. SIAM JOURNAL ON IMAGING SCIENCES 2016; 9:1004-1041. [PMID: 29973971 PMCID: PMC6028195 DOI: 10.1137/15m1042280] [Citation(s) in RCA: 54] [Impact Index Per Article: 6.0] [Reference Citation Analysis] [Abstract] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 05/21/2023]
Abstract
We introduce a method to recover a continuous domain representation of a piecewise constant two-dimensional image from few low-pass Fourier samples. Assuming the edge set of the image is localized to the zero set of a trigonometric polynomial, we show the Fourier coefficients of the partial derivatives of the image satisfy a linear annihilation relation. We present necessary and sufficient conditions for unique recovery of the image from finite low-pass Fourier samples using the annihilation relation. We also propose a practical two-stage recovery algorithm which is robust to model-mismatch and noise. In the first stage we estimate a continuous domain representation of the edge set of the image. In the second stage we perform an extrapolation in Fourier domain by a least squares two-dimensional linear prediction, which recovers the exact Fourier coefficients of the underlying image. We demonstrate our algorithm on the super-resolution recovery of MRI phantoms and real MRI data from low-pass Fourier samples, which shows benefits over standard approaches for single-image super-resolution MRI.
Collapse
Affiliation(s)
- Greg Ongie
- Department of Mathematics, University of Iowa, Iowa City, Iowa
| | - Mathews Jacob
- Department of Electrical and Computer Engineering, University of Iowa, Iowa City, Iowa
| |
Collapse
|
26
|
Zhang Y, Dong Z, Phillips P, Wang S, Ji G, Yang J. Exponential Wavelet Iterative Shrinkage Thresholding Algorithm for compressed sensing magnetic resonance imaging. Inf Sci (N Y) 2015. [DOI: 10.1016/j.ins.2015.06.017] [Citation(s) in RCA: 76] [Impact Index Per Article: 7.6] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/15/2022]
|
27
|
Zhou Z, Li R, Zhao X, He L, Wang X, Wang J, Balu N, Yuan C. Evaluation of 3D multi-contrast joint intra- and extracranial vessel wall cardiovascular magnetic resonance. J Cardiovasc Magn Reson 2015; 17:41. [PMID: 26013973 PMCID: PMC4446075 DOI: 10.1186/s12968-015-0143-z] [Citation(s) in RCA: 58] [Impact Index Per Article: 5.8] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/15/2014] [Accepted: 05/01/2015] [Indexed: 12/12/2022] Open
Abstract
BACKGROUND Multi-contrast vessel wall cardiovascular magnetic resonance (CMR) has demonstrated its capability for atherosclerotic plaque morphology measurement and component characterization in different vasculatures. However, limited coverage and partial volume effect with conventional two-dimensional (2D) techniques might cause lesion underestimation. The aim of this work is to evaluate the performance in a) blood suppression and b) vessel wall delineation of three-dimensional (3D) multi-contrast joint intra- and extracranial vessel wall imaging at 3T. METHODS Three multi-contrast 3D black blood (BB) sequences with T1, T2 and heavy T1 weighting and a custom designed 36-channel neurovascular coil covering the entire intra- and extracranial vasculature have been used and investigated in this study. Two healthy subjects were recruited for sequence parameter optimization and twenty-five patients were consecutively scanned for image quality and blood suppression assessment. Qualitative image scores of vessel wall delineation as well as quantitative Signal-to-Noise Ratio (SNR) and Contrast-to-Noise Ratio (CNR) were evaluated at five typical locations ranging from common carotid arteries to middle cerebral arteries. RESULTS The 3D multi-contrast images acquired within 15mins allowed the vessel wall visualization with 0.8 mm isotropic spatial resolution covering intra- and extracranial segments. Quantitative wall and lumen SNR measurements for each sequence showed effective blood suppression at all selected locations (P < 0.0001). Although the wall-lumen CNR varied across measured locations, each sequence provided good or adequate image quality in both intra- and extracranial segments. CONCLUSIONS The proposed 3D multi-contrast vessel wall technique provides isotropic resolution and time efficient solution for joint intra- and extracranial vessel wall CMR.
Collapse
Affiliation(s)
- Zechen Zhou
- Center for Biomedical Imaging Research, Department of Biomedical Engineering, School of Medicine, Tsinghua University, Beijing, China.
| | - Rui Li
- Center for Biomedical Imaging Research, Department of Biomedical Engineering, School of Medicine, Tsinghua University, Beijing, China.
| | - Xihai Zhao
- Center for Biomedical Imaging Research, Department of Biomedical Engineering, School of Medicine, Tsinghua University, Beijing, China.
| | - Le He
- Center for Biomedical Imaging Research, Department of Biomedical Engineering, School of Medicine, Tsinghua University, Beijing, China.
| | - Xiaole Wang
- Department of Biomedical Engineering, Tsinghua University, Beijing, China.
| | - Jinnan Wang
- Department of Radiology, University of Washington, Seattle, WA, USA.
- Philips Research North America, Briarcliff Manor, NY, USA.
| | - Niranjan Balu
- Department of Radiology, University of Washington, Seattle, WA, USA.
| | - Chun Yuan
- Center for Biomedical Imaging Research, Department of Biomedical Engineering, School of Medicine, Tsinghua University, Beijing, China.
- Department of Radiology, University of Washington, Seattle, WA, USA.
| |
Collapse
|