1
|
Hickey S, Reichert A, Ptacek W, Bielak L, Reiss S, Fischer J, Gunashekar DD, Bortfeld T, Bock M. Simultaneous T 2 -weighted real-time MRI of two orthogonal slices. Magn Reson Med 2023; 90:2388-2399. [PMID: 37427459 DOI: 10.1002/mrm.29795] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/22/2022] [Revised: 06/22/2023] [Accepted: 06/23/2023] [Indexed: 07/11/2023]
Abstract
PURPOSE MR guidance is used during therapy to detect and compensate for lesion motion. T2 -weighted MRI often has a superior lesion contrast in comparison to T1 -weighted real-time imaging. The purpose of this work was to design a fast T2 -weighted sequence capable of simultaneously acquiring two orthogonal slices, enabling real-time tracking of lesions. METHODS To generate a T2 contrast in two orthogonal slices simultaneously, a sequence (Ortho-SFFP-Echo) was designed that samples the T2 -weighted spin echo (S- ) signal in a TR-interleaved acquisition of two slices. Slice selection and phase-encoding directions are swapped between the slices, leading to a unique set of spin-echo signal conditions. To minimize motion-related signal dephasing, additional flow-compensation strategies are implemented. In both the abdominal breathing phantom and in vivo experiments, a time series was acquired using Ortho-SSFP-Echo. The centroid of the target was tracked in postprocessing steps. RESULTS In the phantom, the lesion could be identified and delineated in the dynamic images. In the volunteer experiments, the kidney was visualized with a T2 contrast at a temporal resolution of 0.45 s under free-breathing conditions. A respiratory belt demonstrated a strong correlation with the time course of the kidney centroid in the head-foot direction. A hypointense saturation band at the slice overlap did not inhibit lesion tracking in the semi-automatic postprocessing steps. CONCLUSION The Ortho-SFFP-Echo sequence delivers real-time images with a T2 -weighted contrast in two orthogonal slices. The sequence allows for simultaneous acquisition, which could be beneficial for real-time motion tracking in radiotherapy or interventional MRI.
Collapse
Affiliation(s)
- Samantha Hickey
- Division of Medical Physics, Department of Diagnostic and Interventional Radiology, University Medical Center Freiburg, Faculty of Medicine, University of Freiburg, Freiburg, Germany
| | - Andreas Reichert
- Division of Medical Physics, Department of Diagnostic and Interventional Radiology, University Medical Center Freiburg, Faculty of Medicine, University of Freiburg, Freiburg, Germany
| | | | - Lars Bielak
- Division of Medical Physics, Department of Diagnostic and Interventional Radiology, University Medical Center Freiburg, Faculty of Medicine, University of Freiburg, Freiburg, Germany
- German Cancer Consortium (DKTK), Partner Site Freiburg, Freiburg, Germany
| | - Simon Reiss
- Division of Medical Physics, Department of Diagnostic and Interventional Radiology, University Medical Center Freiburg, Faculty of Medicine, University of Freiburg, Freiburg, Germany
| | - Johannes Fischer
- Division of Medical Physics, Department of Diagnostic and Interventional Radiology, University Medical Center Freiburg, Faculty of Medicine, University of Freiburg, Freiburg, Germany
| | - Deepa Darshini Gunashekar
- Division of Medical Physics, Department of Diagnostic and Interventional Radiology, University Medical Center Freiburg, Faculty of Medicine, University of Freiburg, Freiburg, Germany
| | - Thomas Bortfeld
- Division of Radiation Biophysics, Department of Radiation Oncology, Massachusetts General Hospital and Harvard Medical School, Boston, Massachusetts, USA
| | - Michael Bock
- Division of Medical Physics, Department of Diagnostic and Interventional Radiology, University Medical Center Freiburg, Faculty of Medicine, University of Freiburg, Freiburg, Germany
| |
Collapse
|
2
|
Chen F, Li S, Sun D. Methods of Blood Oxygen Level-Dependent Magnetic Resonance Imaging Analysis for Evaluating Renal Oxygenation. Kidney Blood Press Res 2018. [PMID: 29539614 DOI: 10.1159/000488072] [Citation(s) in RCA: 21] [Impact Index Per Article: 3.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/19/2022] Open
Abstract
Blood oxygen level-dependent magnetic resonance imaging (BOLD MRI) has recently been utilized as a noninvasive tool for evaluating renal oxygenation. Several methods have been proposed for analyzing BOLD images. Regional ROI selection is the earliest and most widely used method for BOLD analysis. In the last 20 years, many investigators have used this method to evaluate cortical and medullary oxygenation in patients with ischemic nephropathy, hypertensive nephropathy, diabetic nephropathy, chronic kidney disease (CKD), acute kidney injury and renal allograft rejection. However, clinical trials of BOLD MRI using regional ROI selection revealed that it was difficult to distinguish the renal cortico-medullary zones with this method, and that it was susceptible to observer variability. To overcome these deficiencies, several new methods were proposed for analyzing BOLD images, including the compartmental approach, fractional hypoxia method, concentric objects (CO) method and twelve-layer concentric objects (TLCO) method. The compartmental approach provides an algorithm to judge whether the pixel belongs to the cortex or medulla. Fractional kidney hypoxia, measured by using BOLD MRI, was negatively correlated with renal blood flow, tissue perfusion and glomerular filtration rate (GFR) in patients with atherosclerotic renal artery stenosis. The CO method divides the renal parenchyma into six or twelve layers of thickness in each coronal slice of BOLD images and provides a R2* radial profile curve. The slope of the R2* curve associated positively with eGFR in CKD patients. Indeed, each method invariably has advantages and disadvantages, and there is generally no consensus method so far. Undoubtedly, analytic approaches for BOLD MRI with better reproducibility would assist clinicians in monitoring the degree of kidney hypoxia and thus facilitating timely reversal of tissue hypoxia.
Collapse
Affiliation(s)
- Fen Chen
- Department of Nephrology, Xuzhou Medical University, Xuzhou, China
| | - Shulin Li
- Department of Nephrology, Xuzhou Medical University, Xuzhou, China.,Department of Nephrology, Affiliated Hospital of Xuzhou Medical University, Xuzhou, China
| | - Dong Sun
- Department of Nephrology, Xuzhou Medical University, Xuzhou, China.,Department of Nephrology, Affiliated Hospital of Xuzhou Medical University, Xuzhou, China
| |
Collapse
|