Sheng L, Yuan E, Yuan F, Song B. Amide proton transfer-weighted imaging of the abdomen: Current progress and future directions. Magn Reson Imaging 2024; 107:88-99. [PMID: 38242255 DOI: 10.1016/j.mri.2024.01.006] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/17/2023] [Revised: 01/13/2024] [Accepted: 01/14/2024] [Indexed: 01/21/2024]
Abstract
The chemical exchange saturation transfer technique serves as a valuable tool for generating in vivo image contrast based on the content of various proton groups, including amide protons, amine protons, and aliphatic protons. Among these, amide proton transfer-weighted (APTw) imaging has seen extensive development as a means to assess the biochemical status of lesions. The exchange from saturated amide protons to bulk water protons during and following the saturation ratio frequency pulse contributes to detectable APT signals. While APTw imaging has garnered significant attention in the central nervous system, demonstrating noteworthy findings in cerebral neoplasia, stroke, and Alzheimer's disease over the past decade, its application in the abdomen has been a relatively recent progression. Notably, studies have explored its utility in hepatocellular carcinoma, prostate cancer, and cervical carcinoma within the abdominal context. Despite these advancements, there is a paucity of reviews on APTw imaging in abdominal applications. This paper aims to fill this gap by providing a concise overview of the fundamental theories underpinning APTw imaging. Additionally, we systematically summarize its diverse clinical applications in the abdomen, with a particular focus on the digestive and urogenital systems. Finally, the manuscript concludes by discussing technical limitations and factors influencing APTw imaging in abdominal applications, along with prospects for future research.
Collapse
Affiliation(s)
- Liuji Sheng
- Department of Radiology, West China Hospital, Sichuan University, Chengdu, Sichuan, China; Functional and Molecular Imaging Key Laboratory of Sichuan Province, West China Hospital, Sichuan University, Chengdu, Sichuan, China
| | - Enyu Yuan
- Department of Radiology, West China Hospital, Sichuan University, Chengdu, Sichuan, China; Functional and Molecular Imaging Key Laboratory of Sichuan Province, West China Hospital, Sichuan University, Chengdu, Sichuan, China
| | - Fang Yuan
- Department of Radiology, West China Hospital, Sichuan University, Chengdu, Sichuan, China.
| | - Bin Song
- Department of Radiology, West China Hospital, Sichuan University, Chengdu, Sichuan, China; Functional and Molecular Imaging Key Laboratory of Sichuan Province, West China Hospital, Sichuan University, Chengdu, Sichuan, China; Department of Radiology, Sanya People's Hospital, Sanya, Hainan, China.
| |
Collapse
|
2
|
Chauvie S, Mazzoni LN, O’Doherty J. A Review on the Use of Imaging Biomarkers in Oncology Clinical Trials: Quality Assurance Strategies for Technical Validation. Tomography 2023; 9:1876-1902. [PMID: 37888741 PMCID: PMC10610870 DOI: 10.3390/tomography9050149] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/16/2023] [Revised: 10/10/2023] [Accepted: 10/13/2023] [Indexed: 10/28/2023] Open
Abstract
Imaging biomarkers (IBs) have been proposed in medical literature that exploit images in a quantitative way, going beyond the visual assessment by an imaging physician. These IBs can be used in the diagnosis, prognosis, and response assessment of several pathologies and are very often used for patient management pathways. In this respect, IBs to be used in clinical practice and clinical trials have a requirement to be precise, accurate, and reproducible. Due to limitations in imaging technology, an error can be associated with their value when considering the entire imaging chain, from data acquisition to data reconstruction and subsequent analysis. From this point of view, the use of IBs in clinical trials requires a broadening of the concept of quality assurance and this can be a challenge for the responsible medical physics experts (MPEs). Within this manuscript, we describe the concept of an IB, examine some examples of IBs currently employed in clinical practice/clinical trials and analyze the procedure that should be carried out to achieve better accuracy and reproducibility in their use. We anticipate that this narrative review, written by the components of the EFOMP working group on "the role of the MPEs in clinical trials"-imaging sub-group, can represent a valid reference material for MPEs approaching the subject.
Collapse
Affiliation(s)
- Stephane Chauvie
- Medical Physics Division, Santa Croce e Carle Hospital, 12100 Cuneo, Italy;
| | | | - Jim O’Doherty
- Siemens Medical Solutions, Malvern, PA 19355, USA;
- Department of Radiology & Radiological Sciences, Medical University of South Carolina, Charleston, SC 20455, USA
- Radiography & Diagnostic Imaging, University College Dublin, D04 C7X2 Dublin, Ireland
| |
Collapse
|
3
|
Mennecke A, Khakzar KM, German A, Herz K, Fabian MS, Liebert A, Blümcke I, Kasper BS, Nagel AM, Laun FB, Schmidt M, Winkler J, Dörfler A, Zaiss M. 7 tricks for 7 T CEST: Improving the reproducibility of multipool evaluation provides insights into the effects of age and the early stages of Parkinson's disease. NMR IN BIOMEDICINE 2023; 36:e4717. [PMID: 35194865 DOI: 10.1002/nbm.4717] [Citation(s) in RCA: 2] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 10/26/2021] [Revised: 02/10/2022] [Accepted: 02/21/2022] [Indexed: 05/23/2023]
Abstract
The objective of the current study was to optimize the postprocessing pipeline of 7 T chemical exchange saturation transfer (CEST) imaging for reproducibility and to prove this optimization for the detection of age differences and differences between patients with Parkinson's disease versus normal subjects. The following 7 T CEST MRI experiments were analyzed: repeated measurements of a healthy subject, subjects of two age cohorts (14 older, seven younger subjects), and measurements of 12 patients with Parkinson's disease. A slab-selective, B 1 + -homogeneous parallel transmit protocol was used. The postprocessing, consisting of motion correction, smoothing, B 0 -correction, normalization, denoising, B 1 + -correction and Lorentzian fitting, was optimized regarding the intrasubject and intersubject coefficient of variation (CoV) of the amplitudes of the amide pool and the aliphatic relayed nuclear Overhauser effect (rNOE) pool within the brain. Seven "tricks" for postprocessing accomplished an improvement of the mean voxel CoV of the amide pool and the aliphatic rNOE pool amplitudes of less than 5% and 3%, respectively. These postprocessing steps are: motion correction with interpolation of the motion of low-signal offsets (1) using the amide pool frequency offset image as reference (2), normalization of the Z-spectrum using the outermost saturated measurements (3), B 0 correction of the Z-spectrum with moderate spline smoothing (4), denoising using principal component analysis preserving the 11 highest intensity components (5), B 1 + correction using a linear fit (6) and Lorentzian fitting using the five-pool fit model (7). With the optimized postprocessing pipeline, a significant age effect in the amide pool can be detected. Additionally, for the first time, an aliphatic rNOE contrast between subjects with Parkinson's disease and age-matched healthy controls in the substantia nigra is detected. We propose an optimized postprocessing pipeline for CEST multipool evaluation. It is shown that by the use of these seven "tricks", the reproducibility and, thus, the statistical power of a CEST measurement, can be greatly improved and subtle changes can be detected.
Collapse
Affiliation(s)
- Angelika Mennecke
- Institute of Neuroradiology, University Hospital Erlangen, Friedrich-Alexander-Universität Erlangen-Nürnberg (FAU), Erlangen, Germany
| | - Katrin M Khakzar
- Institute of Neuroradiology, University Hospital Erlangen, Friedrich-Alexander-Universität Erlangen-Nürnberg (FAU), Erlangen, Germany
| | - Alexander German
- Institute of Neuroradiology, University Hospital Erlangen, Friedrich-Alexander-Universität Erlangen-Nürnberg (FAU), Erlangen, Germany
| | - Kai Herz
- Max Planck Institute for Biological Cybernetics, Tübingen, Germany
- Department of Biomedical Magnetic Resonance, University of Tuebingen, Tuebingen, Germany
| | - Moritz S Fabian
- Institute of Neuroradiology, University Hospital Erlangen, Friedrich-Alexander-Universität Erlangen-Nürnberg (FAU), Erlangen, Germany
| | - Andrzej Liebert
- Institute of Radiology, University Hospital Erlangen, Friedrich-Alexander-Universität Erlangen-Nürnberg (FAU), Erlangen, Germany
| | - Ingmar Blümcke
- Institute of Neuropathology, University Hospital Erlangen, Friedrich-Alexander-Universität Erlangen-Nürnberg (FAU), Erlangen, Germany
| | - Burkhard S Kasper
- Department of Neurology, Epilepsy Centre, University Hospital Erlangen, Friedrich-Alexander-Universität Erlangen-Nürnberg (FAU), Erlangen, Germany
| | - Armin M Nagel
- Institute of Radiology, University Hospital Erlangen, Friedrich-Alexander-Universität Erlangen-Nürnberg (FAU), Erlangen, Germany
| | - Frederik B Laun
- Institute of Radiology, University Hospital Erlangen, Friedrich-Alexander-Universität Erlangen-Nürnberg (FAU), Erlangen, Germany
| | - Manuel Schmidt
- Institute of Neuroradiology, University Hospital Erlangen, Friedrich-Alexander-Universität Erlangen-Nürnberg (FAU), Erlangen, Germany
| | - Jürgen Winkler
- Department of Neurology, Epilepsy Centre, University Hospital Erlangen, Friedrich-Alexander-Universität Erlangen-Nürnberg (FAU), Erlangen, Germany
| | - Arnd Dörfler
- Institute of Neuroradiology, University Hospital Erlangen, Friedrich-Alexander-Universität Erlangen-Nürnberg (FAU), Erlangen, Germany
| | - Moritz Zaiss
- Institute of Neuroradiology, University Hospital Erlangen, Friedrich-Alexander-Universität Erlangen-Nürnberg (FAU), Erlangen, Germany
| |
Collapse
|
4
|
Cember ATJ, Nanga RPR, Reddy R. Glutamate-weighted CEST (gluCEST) imaging for mapping neurometabolism: An update on the state of the art and emerging findings from in vivo applications. NMR IN BIOMEDICINE 2023; 36:e4780. [PMID: 35642353 DOI: 10.1002/nbm.4780] [Citation(s) in RCA: 8] [Impact Index Per Article: 8.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Subscribe] [Scholar Register] [Received: 11/01/2021] [Revised: 05/27/2022] [Accepted: 05/30/2022] [Indexed: 05/23/2023]
Abstract
Glutamate is the primary excitatory neurotransmitter in the mammalian central nervous system. As such, its proper regulation is essential to the healthy function of the human brain, and dysregulation of glutamate metabolism and compartmentalization underlies numerous neurological and neuropsychiatric pathologies. Glutamate-weighted chemical exchange saturation transfer (gluCEST) MRI is one of the only ways to non-invasively observe the relative concentration and spatial distribution of glutamate in the human brain. In the past 10 years, gluCEST has developed from a proof-of-concept experiment carried out in imaging phantoms and model systems to an increasingly sophisticated technique applied to reveal deviations from baseline neural metabolism in human beings, most notably in patients experiencing seizures of various origins or those on the psychosis spectrum. This article traces that progress, including in-depth discussion of the technical specifics of gluCEST and potential challenges to performing these experiments rigorously. We discuss the neurobiological context of glutamate, including the widely accepted hypotheses and models in the literature regarding its involvement in neurodegenerative diseases and other pathology. We then review the state of the art of in vivo glutamate detection by magnetic resonance imaging and the limitations on this front of in vivo MR spectroscopy. The gluCEST experiment is introduced and its advantages, challenges and limitations are thoroughly explored, beginning with the phantom experiment results demonstrated in the initial publication, through the latest approaches to correcting human brain images for B1 inhomogeneity. We then give a comprehensive overview of preclinical applications demonstrated to date, including Alzheimer's disease, Parkinson's disease, Huntington's disease, Traumatic brain injury and cancer, followed by a similar discussion of human studies. Finally, we highlight emerging applications, and discuss technical improvements on the horizon that hold promise for improving the robustness and versatility of gluCEST and its increasing presence in the arena of translational and precision medicine.
Collapse
Affiliation(s)
- Abigail T J Cember
- Center for Advanced Metabolic Imaging in Precision Medicine (CAMIPM), Department of Radiology, University of Pennsylvania
| | - Ravi Prakash Reddy Nanga
- Center for Advanced Metabolic Imaging in Precision Medicine (CAMIPM), Department of Radiology, University of Pennsylvania
| | - Ravinder Reddy
- Center for Advanced Metabolic Imaging in Precision Medicine (CAMIPM), Department of Radiology, University of Pennsylvania
| |
Collapse
|
5
|
Glang F, Fabian MS, German A, Khakzar KM, Mennecke A, Liebert A, Herz K, Liebig P, Kasper BS, Schmidt M, Zuazua E, Nagel AM, Laun FB, Dörfler A, Scheffler K, Zaiss M. Linear projection-based chemical exchange saturation transfer parameter estimation. NMR IN BIOMEDICINE 2023; 36:e4697. [PMID: 35067998 DOI: 10.1002/nbm.4697] [Citation(s) in RCA: 1] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 06/10/2021] [Revised: 12/14/2021] [Accepted: 01/15/2022] [Indexed: 05/23/2023]
Abstract
Isolated evaluation of multiparametric in vivo chemical exchange saturation transfer (CEST) MRI often requires complex computational processing for both correction of B0 and B1 inhomogeneity and contrast generation. For that, sufficiently densely sampled Z-spectra need to be acquired. The list of acquired frequency offsets largely determines the total CEST acquisition time, while potentially representing redundant information. In this work, a linear projection-based multiparametric CEST evaluation method is introduced that offers fast B0 and B1 inhomogeneity correction, contrast generation and feature selection for CEST data, enabling reduction of the overall measurement time. To that end, CEST data acquired at 7 T in six healthy subjects and in one brain tumor patient were conventionally evaluated by interpolation-based inhomogeneity correction and Lorentzian curve fitting. Linear regression was used to obtain coefficient vectors that directly map uncorrected data to corrected Lorentzian target parameters. L1-regularization was applied to find subsets of the originally acquired CEST measurements that still allow for such a linear projection mapping. The linear projection method allows fast and interpretable mapping from acquired raw data to contrast parameters of interest, generalizing from healthy subject training data to unseen healthy test data and to the tumor patient dataset. The L1-regularization method shows that a fraction of the acquired CEST measurements is sufficient to preserve tissue contrasts, offering up to a 2.8-fold reduction of scan time. Similar observations as for the 7-T data can be made for data from a clinical 3-T scanner. Being a fast and interpretable computation step, the proposed method is complementary to neural networks that have recently been employed for similar purposes. The scan time acceleration offered by the L1-regularization ("CEST-LASSO") constitutes a step towards better applicability of multiparametric CEST protocols in a clinical context.
Collapse
Affiliation(s)
- Felix Glang
- Magnetic Resonance Center, Max Planck Institute for Biological Cybernetics, Tübingen, Germany
| | - Moritz S Fabian
- Department of Neuroradiology, University Hospital Erlangen, Friedrich-Alexander Universität Erlangen-Nürnberg, Erlangen, Germany
| | - Alexander German
- Department of Neuroradiology, University Hospital Erlangen, Friedrich-Alexander Universität Erlangen-Nürnberg, Erlangen, Germany
| | - Katrin M Khakzar
- Department of Neuroradiology, University Hospital Erlangen, Friedrich-Alexander Universität Erlangen-Nürnberg, Erlangen, Germany
| | - Angelika Mennecke
- Department of Neuroradiology, University Hospital Erlangen, Friedrich-Alexander Universität Erlangen-Nürnberg, Erlangen, Germany
| | - Andrzej Liebert
- Institute of Radiology, University Hospital Erlangen, Friedrich-Alexander-Universität Erlangen-Nürnberg (FAU), Germany
| | - Kai Herz
- Magnetic Resonance Center, Max Planck Institute for Biological Cybernetics, Tübingen, Germany
- Department of Biomedical Magnetic Resonance, Eberhard Karls University Tübingen, Tübingen, Germany
| | | | - Burkhard S Kasper
- Department of Neurology, University Clinic of Friedrich Alexander University Erlangen-Nürnberg, Erlangen, Germany
| | - Manuel Schmidt
- Department of Neuroradiology, University Hospital Erlangen, Friedrich-Alexander Universität Erlangen-Nürnberg, Erlangen, Germany
| | - Enrique Zuazua
- Department of Data Science, Friedrich-Alexander-Universität Erlangen, Erlangen, Germany
| | - Armin M Nagel
- Institute of Radiology, University Hospital Erlangen, Friedrich-Alexander-Universität Erlangen-Nürnberg (FAU), Germany
| | - Frederik B Laun
- Institute of Radiology, University Hospital Erlangen, Friedrich-Alexander-Universität Erlangen-Nürnberg (FAU), Germany
| | - Arnd Dörfler
- Department of Neuroradiology, University Hospital Erlangen, Friedrich-Alexander Universität Erlangen-Nürnberg, Erlangen, Germany
| | - Klaus Scheffler
- Magnetic Resonance Center, Max Planck Institute for Biological Cybernetics, Tübingen, Germany
- Department of Biomedical Magnetic Resonance, Eberhard Karls University Tübingen, Tübingen, Germany
| | - Moritz Zaiss
- Magnetic Resonance Center, Max Planck Institute for Biological Cybernetics, Tübingen, Germany
- Department of Neuroradiology, University Hospital Erlangen, Friedrich-Alexander Universität Erlangen-Nürnberg, Erlangen, Germany
| |
Collapse
|
6
|
Delebarre T, Gras V, Mauconduit F, Vignaud A, Boulant N, Ciobanu L. Efficient optimization of chemical exchange saturation transfer MRI at 7 T using universal pulses and virtual observation points. Magn Reson Med 2023; 90:51-63. [PMID: 36779346 DOI: 10.1002/mrm.29617] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/12/2022] [Revised: 01/17/2023] [Accepted: 01/27/2023] [Indexed: 02/14/2023]
Abstract
PURPOSE To optimize the homogeneity of the presaturation module in a Chemical Exchange Saturation Transfer (CEST) acquisition at 7 T using parallel transmission (pTx). THEORY AND METHODS An optimized pTx-CEST presaturation scheme based on precomputed universal pulses was designed. The optimization was performed by minimizing the L2-norm between the effective B 1 , RMS + $$ {B}_{1,\mathrm{RMS}}^{+} $$ and a given target while imposing energy constraints under virtual observation points (VOPs) supervision. The proposed method was evaluated through simulations and experimentally, both in vitro, on a realistic human head phantom, and in vivo, on healthy volunteers. The results were compared with circular polarization (CP) presaturation and other pTx approaches previously proposed. All experiments were conducted on a 7 T MRI scanner using a commercial 8Tx/32Rx head coil. RESULTS The simulations show that the proposed pTx strategy boosted with VOPs is superior to the CP mode and existent pTx approaches. While the best results are obtained with subject specific pulses, the gain provided by the use of VOPs renders the universal pulses superior to tailored pulses optimized under vendor provided Specific Absorption Rate (SAR) management. In the phantom, the glucose MTR asym $$ {\mathrm{MTR}}_{\mathrm{asym}} $$ map was significantly more homogeneous than with CP (root mean square error [RMSE] 17% vs. 30%). The efficiency of the method for in vivo hydroxyl, glutamate and rNOE weighted CEST acquisitions was also demonstrated. CONCLUSION The use of a pTx presaturation scheme based on universal pulses optimized under VOP SAR management is significantly benefiting CEST imaging at high magnetic field.
Collapse
Affiliation(s)
- Thaddée Delebarre
- NeuroSpin, UMR CEA/CNRS 9027, Paris-Saclay University, Gif-sur-Yvette, France
| | - Vincent Gras
- NeuroSpin, UMR CEA/CNRS 9027, Paris-Saclay University, Gif-sur-Yvette, France
| | - Franck Mauconduit
- NeuroSpin, UMR CEA/CNRS 9027, Paris-Saclay University, Gif-sur-Yvette, France
| | - Alexandre Vignaud
- NeuroSpin, UMR CEA/CNRS 9027, Paris-Saclay University, Gif-sur-Yvette, France
| | - Nicolas Boulant
- NeuroSpin, UMR CEA/CNRS 9027, Paris-Saclay University, Gif-sur-Yvette, France
| | - Luisa Ciobanu
- NeuroSpin, UMR CEA/CNRS 9027, Paris-Saclay University, Gif-sur-Yvette, France
| |
Collapse
|
7
|
Benyard B, Nanga RPR, Wilson NE, Thakuri D, Jacobs PS, Swain A, Kumar D, Reddy R. In vivo reproducibility of 3D relayed NOE in the healthy human brain at 7 T. Magn Reson Med 2023; 89:2295-2304. [PMID: 36744726 PMCID: PMC10078808 DOI: 10.1002/mrm.29600] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/26/2022] [Revised: 01/09/2023] [Accepted: 01/11/2023] [Indexed: 02/07/2023]
Abstract
PURPOSE Nuclear Overhauser effect (NOE) is based on dipolar cross-relaxation mechanism that enables the indirect detection of aliphatic protons via the water proton signal. This work focuses on determining the reproducibility of NOE magnetization transfer ratio (NOEMTR ) and isolated or relayed NOE (rNOE) contributions to the NOE MRI of the healthy human brain at 7 Tesla (T). METHODS We optimized the B 1 + $$ {\mathrm{B}}_1^{+} $$ amplitude and length of the saturation pulse by acquiring NOE images with different B 1 + $$ {\mathrm{B}}_1^{+} $$ values with multiple saturation lengths. Repeated NOE MRI measurements were made on five healthy volunteers by using optimized saturation pulse parameters including correction of B0 and B 1 + $$ {\mathrm{B}}_1^{+} $$ inhomogeneities. To isolate the individual contributions from z-spectra, we have fit the NOE z-spectra using multiple Lorentzians and calculated the total contribution from each pool contributing to the overall NOEMTR contrast. RESULTS We found that a saturation amplitude of 0.72 μT and a length of 3 s provided the highest contrast. We found that the mean NOEMTR value in gray matter (GM) was 26%, and in white matter (WM) was 33.3% across the 3D slab of the brain. The mean rNOE contributions from GM and WM values were 8.9% and 9.6%, which were ∼10% of the corresponding total NOEMTR signal. The intersubject coefficient of variations (CoVs) of NOEMTR from GM and WM were 4.5% and 6.5%, respectively, whereas the CoVs of rNOE were 4.8% and 5.6%, respectively. The intrasubject CoVs of the NOEMTR range was 2.1%-4.2%, and rNOE range was 2.9%-10.5%. CONCLUSION This work has demonstrated an excellent reproducibility of both inter- and intrasubject NOEMTR and rNOE metrics in healthy human brains at 7 T.
Collapse
Affiliation(s)
- Blake Benyard
- Center for Metabolic Imaging in Precision Medicine (CAMIPM), Department of Radiology, Perelman School of Medicine at the University of Pennsylvania, Philadelphia, Pennsylvania, USA
| | - Ravi Prakash Reddy Nanga
- Center for Metabolic Imaging in Precision Medicine (CAMIPM), Department of Radiology, Perelman School of Medicine at the University of Pennsylvania, Philadelphia, Pennsylvania, USA
| | - Neil E Wilson
- Center for Metabolic Imaging in Precision Medicine (CAMIPM), Department of Radiology, Perelman School of Medicine at the University of Pennsylvania, Philadelphia, Pennsylvania, USA
| | - Deepa Thakuri
- Center for Metabolic Imaging in Precision Medicine (CAMIPM), Department of Radiology, Perelman School of Medicine at the University of Pennsylvania, Philadelphia, Pennsylvania, USA
| | - Paul S Jacobs
- Center for Metabolic Imaging in Precision Medicine (CAMIPM), Department of Radiology, Perelman School of Medicine at the University of Pennsylvania, Philadelphia, Pennsylvania, USA
| | - Anshuman Swain
- Center for Metabolic Imaging in Precision Medicine (CAMIPM), Department of Radiology, Perelman School of Medicine at the University of Pennsylvania, Philadelphia, Pennsylvania, USA
| | - Dushyant Kumar
- Center for Metabolic Imaging in Precision Medicine (CAMIPM), Department of Radiology, Perelman School of Medicine at the University of Pennsylvania, Philadelphia, Pennsylvania, USA
| | - Ravinder Reddy
- Center for Metabolic Imaging in Precision Medicine (CAMIPM), Department of Radiology, Perelman School of Medicine at the University of Pennsylvania, Philadelphia, Pennsylvania, USA
| |
Collapse
|
8
|
Lévy S, Herrler J, Liebert A, Tkotz K, Fabian MS, Eisen C, Grodzki D, Uder M, Dörfler A, Zaiss M, Nagel AM. Clinically compatible subject-specific dynamic parallel transmit pulse design for homogeneous fat saturation and water-excitation at 141657T: Proof-of-concept for 14165CEST MRI of the brain. Magn Reson Med 2022; 89:77-94. [PMID: 36128895 DOI: 10.1002/mrm.29412] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/17/2022] [Revised: 07/25/2022] [Accepted: 07/25/2022] [Indexed: 11/06/2022]
Abstract
PURPOSE To evaluate the benefits and challenges of dynamic parallel transmit (pTx) pulses for fat saturation (FS) and water-excitation (WE), in the context of CEST MRI. METHODS "Universal" kT -points (for FS) and spiral non-selective (for WE) trajectories were optimized offline for flip angle (FA) homogeneity. Routines to optimize the pulse shape online, based on the subject's fields maps, were implemented (target FA of 110°/0° for FS, 0°/5° for WE at fat/water frequencies). The pulses were inserted in a CEST sequence with a pTx readout. The different fat suppression schemes and their effects on CEST contrasts were compared in 12 volunteers at 7T. RESULTS With a 25%-shorter pulse duration, pTx FS largely improved the FA homogeneity (root-mean-square-error (RMSE) = 12.3° vs. 53.4° with circularly-polarized mode, at the fat frequency). However, the spectral selectivity was degraded mainly in the cerebellum and close to the sinuses (RMSE = 5.8° vs. 0.2° at the water frequency). Similarly, pTx WE showed a trade-off between FA homogeneity and spectral selectivity compared to pTx non-selective pulses (RMSE = 0.9° and 1.1° at the fat and water frequencies, vs. 4.6° and 0.5°). In the brain, CEST metrics were reduced by up to 31.9% at -3.3 ppm with pTx FS, suggesting a mitigated lipid-induced bias. CONCLUSION This clinically compatible implementation of dynamic pTx pulses improved the fat suppression homogeneity at 7T taking into account the subject-specific B0 heterogeneities online. This study highlights the lipid-induced biases on the CEST z-spectrum. The results are promising for body applications where B0 heterogeneities and fat are more substantial.
Collapse
Affiliation(s)
- Simon Lévy
- Institute of Radiology, Friedrich-Alexander-Universität Erlangen-Nürnberg (FAU), University Hospital Erlangen, Erlangen, Germany
| | - Jürgen Herrler
- Institute of Neuroradiology, Friedrich-Alexander-Universität Erlangen-Nürnberg (FAU), University Hospital Erlangen, Erlangen, Germany
| | - Andrzej Liebert
- Institute of Radiology, Friedrich-Alexander-Universität Erlangen-Nürnberg (FAU), University Hospital Erlangen, Erlangen, Germany
| | - Katharina Tkotz
- Institute of Radiology, Friedrich-Alexander-Universität Erlangen-Nürnberg (FAU), University Hospital Erlangen, Erlangen, Germany
| | - Moritz S Fabian
- Institute of Neuroradiology, Friedrich-Alexander-Universität Erlangen-Nürnberg (FAU), University Hospital Erlangen, Erlangen, Germany
| | - Christian Eisen
- Institute of Radiology, Friedrich-Alexander-Universität Erlangen-Nürnberg (FAU), University Hospital Erlangen, Erlangen, Germany
| | - David Grodzki
- MR Application Predevelopment, Siemens Healthcare, Erlangen, Germany
| | - Michael Uder
- Institute of Radiology, Friedrich-Alexander-Universität Erlangen-Nürnberg (FAU), University Hospital Erlangen, Erlangen, Germany
| | - Arnd Dörfler
- Institute of Neuroradiology, Friedrich-Alexander-Universität Erlangen-Nürnberg (FAU), University Hospital Erlangen, Erlangen, Germany
| | - Moritz Zaiss
- Institute of Neuroradiology, Friedrich-Alexander-Universität Erlangen-Nürnberg (FAU), University Hospital Erlangen, Erlangen, Germany.,High-Field Magnetic Resonance Center, Max-Planck Institute for Biological Cybernetics, Tübingen, Germany
| | - Armin M Nagel
- Institute of Radiology, Friedrich-Alexander-Universität Erlangen-Nürnberg (FAU), University Hospital Erlangen, Erlangen, Germany.,Division of Medical Physics in Radiology, German Cancer Research Center (DKFZ), Heidelberg, Germany
| |
Collapse
|
9
|
Bosch D, Bause J, Geldschläger O, Scheffler K. Optimized ultrahigh field parallel transmission workflow using rapid presaturated TurboFLASH transmit field mapping with a three-dimensional centric single-shot readout. Magn Reson Med 2022; 89:322-330. [PMID: 36120984 DOI: 10.1002/mrm.29459] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/23/2021] [Revised: 07/27/2022] [Accepted: 08/22/2022] [Indexed: 11/07/2022]
Abstract
PURPOSE To evaluate the usage of three-dimensional (3D) presaturated TurboFLASH (satTFL) for B 1 + $$ {\mathrm{B}}_1^{+} $$ and B 0 $$ {\mathrm{B}}_0 $$ mapping on single channel and parallel transmission (pTx) systems. METHODS B 1 + $$ {\mathrm{B}}_1^{+} $$ maps recorded with 3D satTFL were compared to maps from three other 3D B 1 + $$ {\mathrm{B}}_1^{+} $$ mapping sequences in an agar phantom. Furthermore, individual-channel B 1 + $$ {\mathrm{B}}_1^{+} $$ maps of 18 human subjects were recorded with 3D satTFL using B 1 + $$ {\mathrm{B}}_1^{+} $$ interferometry. A neural network was trained for masking of the maps. RESULTS Out of the sequences compared satTFL was the only one with a mapping range exceeding well over 90°. In regions with lower flip angles there was high correspondence between satTFL and AFI. DREAM and double angle method also showed high qualitative similarity, however the magnitude differed from the other two measurements. The individual-channel B 1 + $$ {\mathrm{B}}_1^{+} $$ maps were successfully used for pTx pulse calculation in a separate study. CONCLUSION 3D satTFL can record high-quality B 1 + $$ {\mathrm{B}}_1^{+} $$ maps with a high dynamic range in a short time. Correspondence with AFI maps is high, while measurement duration is reduced drastically.
Collapse
Affiliation(s)
- Dario Bosch
- High-Field MR Center, Max Planck Institute for Biological Cybernetics, Tübingen, Germany
- Department for Biomedical Magnetic Resonance, University of Tübingen, Tübingen, Germany
| | - Jonas Bause
- High-Field MR Center, Max Planck Institute for Biological Cybernetics, Tübingen, Germany
| | - Ole Geldschläger
- High-Field MR Center, Max Planck Institute for Biological Cybernetics, Tübingen, Germany
| | - Klaus Scheffler
- High-Field MR Center, Max Planck Institute for Biological Cybernetics, Tübingen, Germany
- Department for Biomedical Magnetic Resonance, University of Tübingen, Tübingen, Germany
| |
Collapse
|
10
|
Breitling J, Korzowski A, Kempa N, Boyd PS, Paech D, Schlemmer HP, Ladd ME, Bachert P, Goerke S. Motion correction for three-dimensional chemical exchange saturation transfer imaging without direct water saturation artifacts. NMR IN BIOMEDICINE 2022; 35:e4720. [PMID: 35233847 DOI: 10.1002/nbm.4720] [Citation(s) in RCA: 2] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 08/02/2021] [Revised: 11/25/2021] [Accepted: 02/22/2022] [Indexed: 06/14/2023]
Abstract
In chemical exchange saturation transfer (CEST) MRI, motion correction is compromised by the drastically changing image contrast at different frequency offsets, particularly at the direct water saturation. In this study, a simple extension for conventional image registration algorithms is proposed, enabling robust and accurate motion correction of CEST-MRI data. The proposed method uses weighted averaging of motion parameters from a conventional rigid image registration to identify and mitigate erroneously misaligned images. Functionality of the proposed method was verified by ground truth datasets generated from 10 three-dimensional in vivo measurements at 3 T with simulated realistic random rigid motion patterns and noise. Performance was assessed using two different criteria: the maximum image misalignment as a measure for the robustness against direct water saturation artifacts, and the spectral error as a measure of the overall accuracy. For both criteria, the proposed method achieved the best scores compared with two motion-correction algorithms specifically developed to handle the varying contrasts in CEST-MRI. Compared with a straightforward linear interpolation of the motion parameters at frequency offsets close to the direct water saturation, the proposed method offers better performance in the absence of artifacts. The proposed method for motion correction in CEST-MRI allows identification and mitigation of direct water saturation artifacts that occur with conventional image registration algorithms. The resulting improved robustness and accuracy enable reliable motion correction, which is particularly crucial for an automated and carefree evaluation of spectral CEST-MRI data, e.g., for large patient cohorts or in clinical routines.
Collapse
Affiliation(s)
- Johannes Breitling
- Division of Medical Physics in Radiology, German Cancer Research Center (DKFZ), Heidelberg, Germany
| | - Andreas Korzowski
- Division of Medical Physics in Radiology, German Cancer Research Center (DKFZ), Heidelberg, Germany
| | - Neele Kempa
- Division of Medical Physics in Radiology, German Cancer Research Center (DKFZ), Heidelberg, Germany
- Faculty of Physics and Astronomy, University of Heidelberg, Heidelberg, Germany
| | - Philip S Boyd
- Division of Medical Physics in Radiology, German Cancer Research Center (DKFZ), Heidelberg, Germany
- Faculty of Physics and Astronomy, University of Heidelberg, Heidelberg, Germany
| | - Daniel Paech
- Division of Radiology, German Cancer Research Center (DKFZ), Heidelberg, Germany
| | | | - Mark E Ladd
- Division of Medical Physics in Radiology, German Cancer Research Center (DKFZ), Heidelberg, Germany
- Faculty of Physics and Astronomy, University of Heidelberg, Heidelberg, Germany
- Faculty of Medicine, University of Heidelberg, Heidelberg, Germany
| | - Peter Bachert
- Division of Medical Physics in Radiology, German Cancer Research Center (DKFZ), Heidelberg, Germany
- Faculty of Physics and Astronomy, University of Heidelberg, Heidelberg, Germany
| | - Steffen Goerke
- Division of Medical Physics in Radiology, German Cancer Research Center (DKFZ), Heidelberg, Germany
| |
Collapse
|