1
|
Ramedani M, Moussavi A, Memhave TR, Boretius S. Deep learning-based automated segmentation of cardiac real-time MRI in non-human primates. Comput Biol Med 2025; 189:109894. [PMID: 40086292 DOI: 10.1016/j.compbiomed.2025.109894] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/16/2024] [Revised: 02/16/2025] [Accepted: 02/17/2025] [Indexed: 03/16/2025]
Abstract
Advanced imaging techniques, like magnetic resonance imaging (MRI), have revolutionised cardiovascular disease diagnosis and monitoring in humans and animal models. Real-time (RT) MRI, which can capture a single slice during each consecutive heartbeat while the animal or patient breathes continuously, generates large data sets that necessitate automatic myocardium segmentation to fully exploit these technological advancements. While automatic segmentation is common in human adults, it remains underdeveloped in preclinical animal models. In this study, we developed and trained a fully automated 2D convolutional neural network (CNN) for segmenting the left and right ventricles and the myocardium in non-human primates (NHPs) using RT cardiac MR images of rhesus macaques, in the following referred to as PrimUNet. Based on the U-Net framework, PrimUNet achieved optimal performance with a learning rate of 0.0001, an initial kernel size of 64, a final kernel size of 512, and a batch size of 32. It attained an average Dice score of 0.9, comparable to human studies. Testing PrimUNet on additional RT MRI data from rhesus macaques demonstrated strong agreement with manual segmentation for left ventricular end-diastolic volume (LVEDV), left ventricular end-systolic volume (LVESV), and left ventricular myocardial volume (LVMV). It also performs well on cine MRI data of rhesus macaques and acceptably on those of baboons. PrimUNet is well-suited for automatically segmenting extensive RT MRI data, facilitating strain analyses of individual heartbeats. By eliminating human observer variability, PrimUNet enhances the reliability and reproducibility of data analysis in animal research, thereby advancing translational cardiovascular studies.
Collapse
Affiliation(s)
- Majid Ramedani
- Functional Imaging Laboratory, German Primate Center, Leibniz Institute for Primate Research, Goettingen, Germany; Georg-August University of Goettingen, Goettingen, Germany; DZHK (German Centre for Cardiovascular Research), Partner Site Lower Saxony, Goettingen, Germany
| | - Amir Moussavi
- Functional Imaging Laboratory, German Primate Center, Leibniz Institute for Primate Research, Goettingen, Germany; DZHK (German Centre for Cardiovascular Research), Partner Site Lower Saxony, Goettingen, Germany; Department for Electrical Engineering and Information Technology, South Westphalia University of Applied Sciences, Iserlohn, Germany
| | - Tor Rasmus Memhave
- Functional Imaging Laboratory, German Primate Center, Leibniz Institute for Primate Research, Goettingen, Germany; Georg-August University of Goettingen, Goettingen, Germany; DZHK (German Centre for Cardiovascular Research), Partner Site Lower Saxony, Goettingen, Germany
| | - Susann Boretius
- Functional Imaging Laboratory, German Primate Center, Leibniz Institute for Primate Research, Goettingen, Germany; Georg-August University of Goettingen, Goettingen, Germany; DZHK (German Centre for Cardiovascular Research), Partner Site Lower Saxony, Goettingen, Germany.
| |
Collapse
|
2
|
Castellanos DA, Jang J, Schidlow DN, Brassaw K, Agudelo S, Heuvelink-Marck A, Lipsitz SR, Powell AJ. The impact of audiovisual breathing guidance on respiratory-triggered cardiac magnetic resonance cine imaging. Magn Reson Imaging 2024; 111:15-20. [PMID: 38579974 DOI: 10.1016/j.mri.2024.04.001] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/05/2023] [Revised: 03/15/2024] [Accepted: 04/02/2024] [Indexed: 04/07/2024]
Abstract
BACKGROUND In patients who have difficulty holding their breath, a free breathing (FB) respiratory-triggered (RT) bSSFP cine technique may be used. However, this technique may have inferior image quality and a longer scan time than breath-hold (BH) bSSFP cine acquisitions. This study examined the effect of an audiovisual breathing guidance (BG) system on RT bSSFP cine image quality, scan time, and ventricular measurements. METHODS This study evaluated a BG system that provides audiovisual instructions and feedback on the timing of inspiration and expiration to the patient during image acquisition using input from the respiratory bellows to guide them toward a regular breathing pattern with extended end-expiration. In this single-center prospective study in patients undergoing a clinical cardiac magnetic resonance examination, a ventricular short-axis stack of bSSFP cine images was acquired using 3 techniques in each patient: 1) FB and RT (FBRT), 2) BG system and RT (BGRT), and 3) BH. The 3 acquisitions were compared for image quality metrics (endocardial edge definition, motion artifact, and blood-to-myocardial contrast) scored on a Likert scale, scan time, and ventricular volumes and mass. RESULTS Thirty-two patients (19 females; median age 21 years, IQR 18-32) completed the study protocol. For scan time, BGRT was faster than FBRT (163 s vs. 345 s, p < 0.001). Endocardial edge definition, motion artifact, and blood-to-myocardial contrast were all better for BGRT than FBRT (p < 0.001). Left ventricular (LV) end-systolic volume (ESV) was smaller (3%, p = 0.02) and LV ejection fraction (EF) was larger (0.5%, p = 0.003) with BGRT than with FBRT. There was no significant difference in LV end-diastolic volume (EDV), LV mass, right ventricular (RV) EDV, RV ESV, and RV EF. Scan times were shorter for BGRT compared to BH. Endocardial edge definition and blood-to-myocardial contrast were better for BH than BGRT. Compared to BH, the LV EDV, LV ESV, RV EDV, and RV ESV were mildly smaller (all differences <7%) for BGRT. CONCLUSIONS The addition of a BG system to RT bSSFP cine acquisitions decreased the scan time and improved image quality. Further exploration of this BG approach is warranted in more diverse populations and with other free breathing sequences.
Collapse
Affiliation(s)
- Daniel A Castellanos
- Department of Cardiology, Boston Children's Hospital, Boston, MA, USA; Department of Pediatrics, Harvard Medical School, Boston, MA, USA.
| | - Jihye Jang
- Philips Healthcare, Gainesville, FL, USA
| | - David N Schidlow
- Department of Cardiology, Boston Children's Hospital, Boston, MA, USA; Department of Pediatrics, Harvard Medical School, Boston, MA, USA
| | - Kinsey Brassaw
- Department of Cardiology, Boston Children's Hospital, Boston, MA, USA
| | - Stephanie Agudelo
- Department of Cardiology, Boston Children's Hospital, Boston, MA, USA
| | | | - Stuart R Lipsitz
- Department of Cardiology, Boston Children's Hospital, Boston, MA, USA; Department of Pediatrics, Harvard Medical School, Boston, MA, USA
| | - Andrew J Powell
- Department of Cardiology, Boston Children's Hospital, Boston, MA, USA; Department of Pediatrics, Harvard Medical School, Boston, MA, USA
| |
Collapse
|
3
|
Tibrewala R, Brantner D, Brown R, Pancoast L, Keerthivasan M, Bruno M, Block KT, Madore B, Sodickson DK, Collins CM. Preliminary Experience with Three Alternative Motion Sensors for 0.55 Tesla MR Imaging. SENSORS (BASEL, SWITZERLAND) 2024; 24:3710. [PMID: 38931494 PMCID: PMC11207459 DOI: 10.3390/s24123710] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 04/09/2024] [Revised: 05/27/2024] [Accepted: 06/05/2024] [Indexed: 06/28/2024]
Abstract
Due to limitations in current motion tracking technologies and increasing interest in alternative sensors for motion tracking both inside and outside the MRI system, in this study we share our preliminary experience with three alternative sensors utilizing diverse technologies and interactions with tissue to monitor motion of the body surface, respiratory-related motion of major organs, and non-respiratory motion of deep-seated organs. These consist of (1) a Pilot-Tone RF transmitter combined with deep learning algorithms for tracking liver motion, (2) a single-channel ultrasound transducer with deep learning for monitoring bladder motion, and (3) a 3D Time-of-Flight camera for observing the motion of the anterior torso surface. Additionally, we demonstrate the capability of these sensors to simultaneously capture motion data outside the MRI environment, which is particularly relevant for procedures like radiation therapy, where motion status could be related to previously characterized cyclical anatomical data. Our findings indicate that the ultrasound sensor can track motion in deep-seated organs (bladder) as well as respiratory-related motion. The Time-of-Flight camera offers ease of interpretation and performs well in detecting surface motion (respiration). The Pilot-Tone demonstrates efficacy in tracking bulk respiratory motion and motion of major organs (liver). Simultaneous use of all three sensors could provide complementary motion information outside the MRI bore, providing potential value for motion tracking during position-sensitive treatments such as radiation therapy.
Collapse
Affiliation(s)
- Radhika Tibrewala
- Bernard and Irene Schwartz Center for Biomedical Imaging, Department of Radiology, New York University Grossman School of Medicine, New York, NY 10016, USA
- Center for Advanced Imaging Innovation and Research (CAIR), Department of Radiology, New York University Grossman School of Medicine, New York, NY 10016, USA
- Vilcek Institute of Graduate Biomedical Sciences, New York University Grossman School of Medicine, New York, NY 10016, USA
| | - Douglas Brantner
- Bernard and Irene Schwartz Center for Biomedical Imaging, Department of Radiology, New York University Grossman School of Medicine, New York, NY 10016, USA
- Center for Advanced Imaging Innovation and Research (CAIR), Department of Radiology, New York University Grossman School of Medicine, New York, NY 10016, USA
| | - Ryan Brown
- Bernard and Irene Schwartz Center for Biomedical Imaging, Department of Radiology, New York University Grossman School of Medicine, New York, NY 10016, USA
- Center for Advanced Imaging Innovation and Research (CAIR), Department of Radiology, New York University Grossman School of Medicine, New York, NY 10016, USA
- Vilcek Institute of Graduate Biomedical Sciences, New York University Grossman School of Medicine, New York, NY 10016, USA
| | - Leanna Pancoast
- Bernard and Irene Schwartz Center for Biomedical Imaging, Department of Radiology, New York University Grossman School of Medicine, New York, NY 10016, USA
- Center for Advanced Imaging Innovation and Research (CAIR), Department of Radiology, New York University Grossman School of Medicine, New York, NY 10016, USA
| | | | - Mary Bruno
- Bernard and Irene Schwartz Center for Biomedical Imaging, Department of Radiology, New York University Grossman School of Medicine, New York, NY 10016, USA
- Center for Advanced Imaging Innovation and Research (CAIR), Department of Radiology, New York University Grossman School of Medicine, New York, NY 10016, USA
| | - Kai Tobias Block
- Bernard and Irene Schwartz Center for Biomedical Imaging, Department of Radiology, New York University Grossman School of Medicine, New York, NY 10016, USA
- Center for Advanced Imaging Innovation and Research (CAIR), Department of Radiology, New York University Grossman School of Medicine, New York, NY 10016, USA
- Vilcek Institute of Graduate Biomedical Sciences, New York University Grossman School of Medicine, New York, NY 10016, USA
| | - Bruno Madore
- Department of Radiology, Brigham and Women’s Hospital, Harvard Medical School, Boston, MA 02115, USA
| | - Daniel K. Sodickson
- Bernard and Irene Schwartz Center for Biomedical Imaging, Department of Radiology, New York University Grossman School of Medicine, New York, NY 10016, USA
- Center for Advanced Imaging Innovation and Research (CAIR), Department of Radiology, New York University Grossman School of Medicine, New York, NY 10016, USA
- Vilcek Institute of Graduate Biomedical Sciences, New York University Grossman School of Medicine, New York, NY 10016, USA
| | - Christopher M. Collins
- Bernard and Irene Schwartz Center for Biomedical Imaging, Department of Radiology, New York University Grossman School of Medicine, New York, NY 10016, USA
- Center for Advanced Imaging Innovation and Research (CAIR), Department of Radiology, New York University Grossman School of Medicine, New York, NY 10016, USA
- Vilcek Institute of Graduate Biomedical Sciences, New York University Grossman School of Medicine, New York, NY 10016, USA
| |
Collapse
|
4
|
Röwer LM, Radke KL, Hußmann J, Malik H, Eichinger M, Voit D, Wielpütz MO, Frahm J, Klee D, Pillekamp F. First experience with real-time magnetic resonance imaging-based investigation of respiratory influence on cardiac function in pediatric congenital heart disease patients with chronic right ventricular volume overload. Pediatr Radiol 2023; 53:2608-2621. [PMID: 37794175 PMCID: PMC10698081 DOI: 10.1007/s00247-023-05765-9] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 05/31/2023] [Revised: 09/03/2023] [Accepted: 09/04/2023] [Indexed: 10/06/2023]
Abstract
BACKGROUND Congenital heart disease (CHD) is often associated with chronic right ventricular (RV) volume overload. Real-time magnetic resonance imaging (MRI) enables the analysis of cardiac function during free breathing. OBJECTIVE To evaluate the influence of respiration in pediatric patients with CHD and chronic RV volume overload. METHODS AND MATERIALS RV volume overload patients (n=6) and controls (n=6) were recruited for cardiac real-time MRI at 1.5 tesla during free breathing. Breathing curves from regions of interest reflecting the position of the diaphragm served for binning images in four different tidal volume classes, each in inspiration and expiration. Tidal volumes were estimated from these curves by data previously obtained by magnetic resonance-compatible spirometry. Ventricular volumes indexed to body surface area and Frank-Starling relationships referenced to the typical tidal volume indexed to body height (TTVi) were compared. RESULTS Indexed RV end-diastolic volume (RV-EDVi) and indexed RV stroke volume (RV-SVi) increased during inspiration (RV-EDVi/TTVi: RV load: + 16 ± 4%; controls: + 22 ± 13%; RV-SVi/TTVi: RV load: + 21 ± 6%; controls: + 35 ± 17%; non-significant for comparison). The increase in RV ejection fraction during inspiration was significantly lower in RV load patients (RV load: + 1.1 ± 2.2%; controls: + 6.1 ± 1.5%; P=0.01). The Frank-Starling relationship of the RV provided a significantly reduced slope estimate in RV load patients (inspiration: RV load: 0.75 ± 0.11; controls: 0.92 ± 0.02; P=0.02). CONCLUSION In pediatric patients with CHD and chronic RV volume overload, cardiac real-time MRI during free breathing in combination with respiratory-based binning indicates an impaired Frank-Starling relationship of the RV.
Collapse
Affiliation(s)
- Lena Maria Röwer
- Department of Diagnostic and Interventional Radiology, Medical Faculty and University Hospital Düsseldorf, Heinrich-Heine-University, Moorenstr. 5, 40225, Düsseldorf, Germany
- Department of General Pediatrics, Neonatology and Pediatric Cardiology, Medical Faculty and University Hospital, Heinrich-Heine-University, Düsseldorf, Germany
| | - Karl Ludger Radke
- Department of Diagnostic and Interventional Radiology, Medical Faculty and University Hospital Düsseldorf, Heinrich-Heine-University, Moorenstr. 5, 40225, Düsseldorf, Germany
| | - Janina Hußmann
- Department of Diagnostic and Interventional Radiology, Medical Faculty and University Hospital Düsseldorf, Heinrich-Heine-University, Moorenstr. 5, 40225, Düsseldorf, Germany
- Department of General Pediatrics, Neonatology and Pediatric Cardiology, Medical Faculty and University Hospital, Heinrich-Heine-University, Düsseldorf, Germany
| | - Halima Malik
- Department of Diagnostic and Interventional Radiology, Medical Faculty and University Hospital Düsseldorf, Heinrich-Heine-University, Moorenstr. 5, 40225, Düsseldorf, Germany
- Department of General Pediatrics, Neonatology and Pediatric Cardiology, Medical Faculty and University Hospital, Heinrich-Heine-University, Düsseldorf, Germany
| | - Monika Eichinger
- Department of Diagnostic and Interventional Radiology with Nuclear Medicine, Thoraxklinik at University of Heidelberg, Heidelberg, Germany
- Department of Diagnostic and Interventional Radiology, Subdivision of Pulmonary Imaging, University Hospital of Heidelberg, Heidelberg, Germany
- Translational Lung Research Center Heidelberg (TLRC), German Center for Lung Research (DZL), Heidelberg, Germany
| | - Dirk Voit
- Biomedical NMR, Max Planck Institute for Multidisciplinary Sciences, Göttingen, Germany
- DZHK (German Centre for Cardiovascular Research), Partner Site Göttingen, Göttingen, Germany
| | - Mark Oliver Wielpütz
- Department of Diagnostic and Interventional Radiology with Nuclear Medicine, Thoraxklinik at University of Heidelberg, Heidelberg, Germany
- Department of Diagnostic and Interventional Radiology, Subdivision of Pulmonary Imaging, University Hospital of Heidelberg, Heidelberg, Germany
- Translational Lung Research Center Heidelberg (TLRC), German Center for Lung Research (DZL), Heidelberg, Germany
| | - Jens Frahm
- Biomedical NMR, Max Planck Institute for Multidisciplinary Sciences, Göttingen, Germany
- DZHK (German Centre for Cardiovascular Research), Partner Site Göttingen, Göttingen, Germany
| | - Dirk Klee
- Department of Diagnostic and Interventional Radiology, Medical Faculty and University Hospital Düsseldorf, Heinrich-Heine-University, Moorenstr. 5, 40225, Düsseldorf, Germany
| | - Frank Pillekamp
- Department of Diagnostic and Interventional Radiology, Medical Faculty and University Hospital Düsseldorf, Heinrich-Heine-University, Moorenstr. 5, 40225, Düsseldorf, Germany.
- Department of General Pediatrics, Neonatology and Pediatric Cardiology, Medical Faculty and University Hospital, Heinrich-Heine-University, Düsseldorf, Germany.
| |
Collapse
|
5
|
Hirsch FW, Frahm J, Sorge I, Klee D, Prenzel F, Krause M, Lacher M, Voit D, Gräfe D. Real-time MRI: a new tool of radiologic imaging in small children. Eur J Pediatr 2023; 182:3405-3417. [PMID: 37249681 PMCID: PMC10460313 DOI: 10.1007/s00431-023-04996-0] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 03/26/2023] [Revised: 04/19/2023] [Accepted: 04/20/2023] [Indexed: 05/31/2023]
Abstract
Real-time MRI (rt-MRI) in children is a new imaging technique that combines the advantages of US - at frame rates of up to 50 images per second - with the quality and features of MRI. Although still subject of research, it has become a standard tool in the diagnostic portfolio of two pediatric radiology departments in Germany. Based on ultrashort acquisition times, any detrimental effects of macroscopic movements of the child and the physiological movements of the organs are negligible. Especially in pediatric brain imaging, rt-MRI has already proven its value. With suitable indications, rt-MRI can reduce anesthesia and sedation examinations in children below 6 years of age by 40% due to its very short examination time and its robustness to motion. There is a high level of acceptance among parents and referrers when diagnostic possibilities and limitations are communicated correctly. CONCLUSION Completely new diagnostic possibilities arise in the imaging of the moving lung, the beating heart, joint movements, and speaking and swallowing, as demonstrated in this video-backed review. WHAT IS KNOWN • MRI in moving children has been burdened with severe artifacts. • Gross motion usually has to be handled by sedation and periodic motion of the heart and lungs has to be compensated with time-consuming techniques until now. WHAT IS NEW • Real-time MRI allows image acquisition with up to 50 frames per second similar to ultrasound frame rate. • Real-time MRI proofs to be very promising for imaging children, reducing examination time and sedation rate drastically.
Collapse
Affiliation(s)
| | - Jens Frahm
- Biomedical NMR, Max Planck Institute for Multidisciplinary Sciences, Gottingen, Germany
| | - Ina Sorge
- Department of Pediatric Radiology, University Hospital, Leipzig, Germany
| | - Dirk Klee
- Department of Radiology, University Hospital, Dusseldorf, Germany
| | - Freerk Prenzel
- Department of Pediatrics, University Hospital, Leipzig, Germany
| | - Matthias Krause
- Department of Neurosurgery, University Hospital, Leipzig, Germany
| | - Martin Lacher
- Department of Pediatrics Surgery, University Hospital, Leipzig, Germany
| | - Dirk Voit
- Biomedical NMR, Max Planck Institute for Multidisciplinary Sciences, Gottingen, Germany
| | - Daniel Gräfe
- Department of Pediatric Radiology, University Hospital, Leipzig, Germany
| |
Collapse
|
6
|
Hirsch FW, Sorge I, Voit D, Frahm J, Prenzel F, Wachowiak R, Anders R, Roth C, Gräfe D. Chest examinations in children with real-time magnetic resonance imaging: first clinical experience. Pediatr Radiol 2023; 53:12-20. [PMID: 35836015 PMCID: PMC9816257 DOI: 10.1007/s00247-022-05421-8] [Citation(s) in RCA: 2] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Figures] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 03/14/2022] [Revised: 05/04/2022] [Accepted: 06/02/2022] [Indexed: 01/24/2023]
Abstract
BACKGROUND Real-time magnetic resonance imaging (MRI) based on a fast low-angle shot technique 2.0 (FLASH 2.0) is highly effective against artifacts caused due to the bulk and pulmonary and cardiac motions of the patient. However, to date, there are no reports on the application of this innovative technique to pediatric lung MRI. OBJECTIVE This study aimed to identify the limits of resolution and image quality of real-time lung MRI in children and to assess the types and minimal size of lesions with these new sequences. MATERIALS AND METHODS In this retrospective study, pathological lung findings in 87 children were classified into 6 subgroups, as detected on conventional MRI: metastases and tumors, consolidation, scars, hyperinflation, interstitial pathology and bronchiectasis. Subsequently, the findings were grouped according to size (4-6 mm, 7-9 mm and ≥ 10 mm) and evaluated for visual delineation of the findings (0 = not visible, 1 = hardly visible and 2 = well visualized). RESULTS Real-time MRI allows for diagnostic, artifact-free thorax images to be obtained, regardless of patient movements. The delineation of findings strongly correlates with the size of the pathology. Metastases, consolidation and scars were visible at 100% when larger than 9 mm. In the 7-9 mm subgroup, the visibility was 83% for metastases, 88% for consolidation and 100% for scars in T2/T1 weighting. Though often visible, smaller pathological lesions of 4-6 mm in size did not regularly meet the expected diagnostic confidence: The visibility of metastases was 18%, consolidation was 64% and scars was 71%. Diffuse interstitial lung changes and hyperinflation, known as "MR-minus pathologies," were not accessible to real-time MRI. CONCLUSION The method provides motion robust images of the lung and thorax. However, the lower sensitivity for small lung lesions is a major limitation for routine use of this technique. Currently, the method is adequate for diagnosing inflammatory lung diseases, atelectasis, effusions and lung scarring in children with irregular breathing patterns or bulk motion on sedation-free MRI. A medium-term goal is to improve the diagnostic accuracy of small nodules and interstitial lesions.
Collapse
Affiliation(s)
- Franz Wolfgang Hirsch
- Department of Pediatric Radiology, University Hospital, Liebigstraße 20a, 04107, Leipzig, Germany.
| | - Ina Sorge
- Department of Pediatric Radiology, University Hospital, Liebigstraße 20a, 04107, Leipzig, Germany
| | - Dirk Voit
- Biomedical NMR, Max Planck Institute for Multidisciplinary Sciences, Göttingen, Germany
| | - Jens Frahm
- Biomedical NMR, Max Planck Institute for Multidisciplinary Sciences, Göttingen, Germany
| | - Freerk Prenzel
- Department of Pediatrics, University Hospital, Leipzig, Germany
| | - Robin Wachowiak
- Department of Pediatric Surgery, University Hospital, Leipzig, Germany
| | - Rebecca Anders
- Department of Pediatric Radiology, University Hospital, Liebigstraße 20a, 04107, Leipzig, Germany
| | - Christian Roth
- Department of Pediatric Radiology, University Hospital, Liebigstraße 20a, 04107, Leipzig, Germany
| | - Daniel Gräfe
- Department of Pediatric Radiology, University Hospital, Liebigstraße 20a, 04107, Leipzig, Germany
| |
Collapse
|
7
|
Knapp J, Tavares de Sousa M, Schönnagel BP. Fetal Cardiovascular MRI - A Systemic Review of the Literature: Challenges, New Technical Developments, and Perspectives. ROFO-FORTSCHR RONTG 2022; 194:841-851. [PMID: 35905903 DOI: 10.1055/a-1761-3500] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/16/2022]
Abstract
BACKGROUND Fetal magnetic resonance imaging (MRI) has become a valuable adjunct to ultrasound in the prenatal diagnosis of congenital pathologies of the central nervous system, thorax, and abdomen. Fetal cardiovascular magnetic resonance (CMR) was limited, mainly by the lack of cardiac gating, and has only recently evolved due to technical developments. METHOD A literature search was performed on PubMed, focusing on technical advancements to perform fetal CMR. In total, 20 publications on cardiac gating techniques in the human fetus were analyzed. RESULTS Fetal MRI is a safe imaging method with no developmental impairments found to be associated with in utero exposure to MRI. Fetal CMR is challenging due to general drawbacks (e. g., fetal motion) and specific limitations such as the difficulty to generate a cardiac gating signal to achieve high spatiotemporal resolution. Promising technical advancements include new methods for fetal cardiac gating, based on novel post-processing approaches and an external hardware device, as well as motion compensation and acceleration techniques. CONCLUSION Newly developed direct and indirect gating approaches were successfully applied to achieve high-quality morphologic and functional imaging as well as quantitative assessment of fetal hemodynamics in research settings. In cases when prenatal echocardiography is limited, e. g., by an unfavorable fetal position in utero, or when its results are inconclusive, fetal CMR could potentially serve as a valuable adjunct in the prenatal assessment of congenital cardiovascular malformations. However, sufficient data on the diagnostic performance and clinical benefit of new fetal CMR techniques is still lacking. KEY POINTS · New fetal cardiac gating methods allow high-quality fetal CMR.. · Motion compensation and acceleration techniques allow for improvement of image quality.. · Fetal CMR could potentially serve as an adjunct to fetal echocardiography in the future.. CITATION FORMAT · Knapp J, Tavares de Sousa M, Schönnagel BP. Fetal Cardiovascular MRI - A Systemic Review of the Literature: Challenges, New Technical Developments, and Perspectives. Fortschr Röntgenstr 2022; 194: 841 - 851.
Collapse
Affiliation(s)
- Janine Knapp
- Diagnostic and Interventional Radiology and Nuclear Medicine, University Medical Center Hamburg-Eppendorf, Hamburg, Germany
| | | | - Björn P Schönnagel
- Diagnostic and Interventional Radiology and Nuclear Medicine, University Medical Center Hamburg-Eppendorf, Hamburg, Germany
| |
Collapse
|
8
|
Röwer LM, Radke KL, Hußmann J, Malik H, Uelwer T, Voit D, Frahm J, Wittsack HJ, Harmeling S, Pillekamp F, Klee D. Comparison of cardiac volumetry using real-time MRI during free-breathing with standard cine MRI during breath-hold in children. Pediatr Radiol 2022; 52:1462-1475. [PMID: 35353211 PMCID: PMC9271116 DOI: 10.1007/s00247-022-05327-5] [Citation(s) in RCA: 9] [Impact Index Per Article: 3.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 12/14/2021] [Revised: 01/13/2022] [Accepted: 02/16/2022] [Indexed: 01/18/2023]
Abstract
BACKGROUND Cardiac real-time magnetic resonance imaging (RT-MRI) provides high-quality images even during free-breathing. Difficulties in post-processing impede its use in clinical routine. OBJECTIVE To demonstrate the feasibility of quantitative analysis of cardiac free-breathing RT-MRI and to compare image quality and volumetry during free-breathing RT-MRI in pediatric patients to standard breath-hold cine MRI. MATERIALS AND METHODS Pediatric patients (n = 22) received cardiac RT-MRI volumetry during free breathing (1.5 T; short axis; 30 frames per s) in addition to standard breath-hold cine imaging in end-expiration. Real-time images were binned retrospectively based on electrocardiography and respiratory bellows. Image quality and volumetry were compared using the European Cardiovascular Magnetic Resonance registry score, structure visibility rating, linear regression and Bland-Altman analyses. RESULTS Additional time for binning of real-time images was 2 min. For both techniques, image quality was rated good to excellent. RT-MRI was significantly more robust against artifacts (P < 0.01). Linear regression revealed good correlations for the ventricular volumes. Bland-Altman plots showed a good limit of agreement (LoA) for end-diastolic volume (left ventricle [LV]: LoA -0.1 ± 2.7 ml/m2, right ventricle [RV]: LoA -1.9 ± 3.4 ml/m2), end-systolic volume (LV: LoA 0.4 ± 1.9 ml/m2, RV: LoA 0.6 ± 2.0 ml/m2), stroke volume (LV: LoA -0.5 ± 2.3 ml/m2, RV: LoA -2.6 ± 3.3 ml/m2) and ejection fraction (LV: LoA -0.5 ± 1.6%, RV: LoA -2.1 ± 2.8%). CONCLUSION Compared to standard cine MRI with breath hold, RT-MRI during free breathing with retrospective respiratory binning offers good image quality, reduced image artifacts enabling fast quantitative evaluations of ventricular volumes in clinical practice under physiological conditions.
Collapse
Affiliation(s)
- Lena Maria Röwer
- Department of General Pediatrics, Neonatology and Pediatric Cardiology, University Children's Hospital, Moorenstr. 5, 40225, Dusseldorf, Germany.
- Department of Diagnostic and Interventional Radiology, Medical Faculty, Heinrich Heine University, Dusseldorf, Germany.
| | - Karl Ludger Radke
- Department of Diagnostic and Interventional Radiology, Medical Faculty, Heinrich Heine University, Dusseldorf, Germany
| | - Janina Hußmann
- Department of General Pediatrics, Neonatology and Pediatric Cardiology, University Children's Hospital, Moorenstr. 5, 40225, Dusseldorf, Germany
- Department of Diagnostic and Interventional Radiology, Medical Faculty, Heinrich Heine University, Dusseldorf, Germany
| | - Halima Malik
- Department of General Pediatrics, Neonatology and Pediatric Cardiology, University Children's Hospital, Moorenstr. 5, 40225, Dusseldorf, Germany
- Department of Diagnostic and Interventional Radiology, Medical Faculty, Heinrich Heine University, Dusseldorf, Germany
| | - Tobias Uelwer
- Department of Computer Science, Heinrich Heine University, Dusseldorf, Germany
| | - Dirk Voit
- Biomedizinische NMR, Max-Planck-Institut für biophysikalische Chemie, Göttingen, Germany
- DZHK (German Centre for Cardiovascular Research), Göttingen, Germany
| | - Jens Frahm
- Biomedizinische NMR, Max-Planck-Institut für biophysikalische Chemie, Göttingen, Germany
- DZHK (German Centre for Cardiovascular Research), Göttingen, Germany
| | - Hans-Joerg Wittsack
- Department of Diagnostic and Interventional Radiology, Medical Faculty, Heinrich Heine University, Dusseldorf, Germany
| | - Stefan Harmeling
- Department of Computer Science, Heinrich Heine University, Dusseldorf, Germany
| | - Frank Pillekamp
- Department of General Pediatrics, Neonatology and Pediatric Cardiology, University Children's Hospital, Moorenstr. 5, 40225, Dusseldorf, Germany
| | - Dirk Klee
- Department of Diagnostic and Interventional Radiology, Medical Faculty, Heinrich Heine University, Dusseldorf, Germany
| |
Collapse
|