In de Braekt T, Aben JP, Maussen M, van den Bosch HCM, Houthuizen P, Roest AAW, van den Boogaard PJ, Lamb HJ, Westenberg JJM. Fully Automated Valve Segmentation for Blood Flow Assessment From 4D Flow MRI Including Automated Cardiac Valve Tracking and Transvalvular Velocity Mapping. J Magn Reson Imaging 2024. [PMID: 38558490 DOI: 10.1002/jmri.29370] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/30/2023] [Revised: 03/18/2024] [Accepted: 03/19/2024] [Indexed: 04/04/2024] Open
Abstract
BACKGROUND Automated 4D flow MRI valvular flow quantification without time-consuming manual segmentation might improve workflow. PURPOSE Compare automated valve segmentation (AS) to manual (MS), and manually corrected automated segmentation (AMS), in corrected atrioventricular septum defect (c-AVSD) patients and healthy volunteers, for assessing net forward volume (NFV) and regurgitation fraction (RF). STUDY TYPE Retrospective. POPULATION 27 c-AVSD patients (median, 23 years; interquartile range, 16-31 years) and 24 healthy volunteers (25 years; 12.5-36.5 years). FIELD STRENGTH/SEQUENCE Whole-heart 4D flow MRI and cine steady-state free precession at 3T. ASSESSMENT After automatic valve tracking, valve annuli were segmented on time-resolved reformatted trans-valvular velocity images by AS, MS, and AMS. NFV was calculated for all valves, and RF for right and left atrioventricular valves (RAVV and LAVV). NFV variation (standard deviation divided by mean NFV) and NFV differences (NFV difference of a valve vs. mean NFV of other valves) expressed internal NFV consistency. STATISTICAL TESTS Comparisons between methods were assessed by Wilcoxon signed-rank tests, and intra/interobserver variability by intraclass correlation coefficients (ICCs). P < 0.05 was considered statistically significant, with multiple testing correction. RESULTS AMS mean analysis time was significantly shorter compared with MS (5.3 ± 1.6 minutes vs. 9.1 ± 2.5 minutes). MS NFV variation (6.0%) was significantly smaller compared with AMS (6.3%), and AS (8.2%). Median NFV difference of RAVV, LAVV, PV, and AoV between segmentation methods ranged from -0.7-1.0 mL, -0.5-2.8 mL, -1.1-3.6 mL, and - 3.1--2.1 mL, respectively. Median RAVV and LAVV RF, between 7.1%-7.5% and 3.8%-4.3%, respectively, were not significantly different between methods. Intraobserver/interobserver agreement for AMS and MS was strong-to-excellent for NFV and RF (ICC ≥0.88). DATA CONCLUSION MS demonstrates strongest internal consistency, followed closely by AMS, and AS. Automated segmentation, with or without manual correction, can be considered for 4D flow MRI valvular flow quantification. LEVEL OF EVIDENCE 3 TECHNICAL EFFICACY: Stage 3.
Collapse
Affiliation(s)
- Thomas In de Braekt
- Department of Radiology, Catharina Hospital, Eindhoven, the Netherlands
- Department of Radiology, Leiden University Medical Center, Leiden, the Netherlands
| | | | - Marc Maussen
- Pie Medical Imaging BV, Maastricht, the Netherlands
| | | | - Patrick Houthuizen
- Department of Cardiology, Catharina Hospital, Eindhoven, the Netherlands
| | - Arno A W Roest
- Department of Pediatric Cardiology, Leiden University Medical Center, Leiden, the Netherlands
| | | | - Hildo J Lamb
- Department of Radiology, Leiden University Medical Center, Leiden, the Netherlands
| | - Jos J M Westenberg
- Department of Radiology, Leiden University Medical Center, Leiden, the Netherlands
| |
Collapse
|
2
|
Aono S, Tsuneta S, Nishioka N, Aoike T, Hirayama H, Ishizaka K, Kwon J, Yoneyama M, Fujima N, Kudo K. Comparison of Echo-Planar Imaging and Compressed Sensing in the Estimation of Flow Metrics from Aortic 4D Flow MR Imaging: A Healthy Volunteer Study. Magn Reson Med Sci 2024:mp.2023-0011. [PMID: 38556273 DOI: 10.2463/mrms.mp.2023-0011] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 04/02/2024] Open
Abstract
PURPOSE Prolonged scanning of time-resolved 3D phase-contrast MRI (4D flow MRI) limits its routine use in clinical practice. An echo-planar imaging (EPI)-based sequence and compressed sensing can reduce the scan duration. We aimed to determine the impact of EPI for 4D flow MRI on the scan duration, image quality, and quantitative flow metrics. METHODS This was a prospective study of 15 healthy volunteers (all male, mean age 33 ± 5 years). Conventional sensitivity encoding (SENSE), EPI with SENSE (EPI), and compressed SENSE (CS) (reduction factors: 6 and 12, respectively) were scanned.Scan duration, qualitative indexes of image quality, and quantitative flow parameters of net flow volume, maximum flow velocity, wall shear stress (WSS), and energy loss (EL) in the ascending aorta were assessed. Two-dimensional phase-contrast cine MRI (2D-PC) was considered the gold standard of net flow volume and maximum flow velocity. RESULTS Compared to SENSE, EPI and CS12 shortened scan durations by 71% and 73% (EPI, 4 min 39 sec; CS6, 7 min 29 sec; CS12, 4 min 14 sec; and SENSE, 15 min 51 sec). Visual image quality was significantly better for EPI than for SENSE and CS (P < 0.001). The net flow volumes obtained with SENSE, EPI, and CS12 and those obtained with 2D-PC were correlated well (r = 0.950, 0.871, and 0.850, respectively). However, the maximum velocity obtained with EPI was significantly underestimated (P < 0.010). The average WSS was significantly higher with EPI than with SENSE, CS6, and CS12 (P < 0.001, P = 0.040, and P = 0.012, respectively). The EL was significantly lower with EPI than with CS6 and CS12 (P = 0.002 and P = 0.007, respectively). CONCLUSION EPI reduced the scan duration, improved visual image quality, and was associated with more accurate net flow volume than CS. However, the flow velocity, WSS, and EL values obtained with EPI and other sequences may not be directly comparable.
Collapse
Affiliation(s)
- Satoru Aono
- Department of Radiological Technology, Hokkaido University Hospital, Sapporo, Hokkaido, Japan
| | - Satonori Tsuneta
- Department of Diagnostic and Interventional Radiology, Hokkaido University Hospital, Sapporo, Hokkaido, Japan
| | - Noriko Nishioka
- Department of Diagnostic and Interventional Radiology, Hokkaido University Hospital, Sapporo, Hokkaido, Japan
| | - Takuya Aoike
- Department of Radiological Technology, Hokkaido University Hospital, Sapporo, Hokkaido, Japan
| | - Hiroyuki Hirayama
- Department of Radiological Technology, Hokkaido University Hospital, Sapporo, Hokkaido, Japan
| | - Kinya Ishizaka
- Department of Radiological Technology, Hokkaido University Hospital, Sapporo, Hokkaido, Japan
| | | | | | - Noriyuki Fujima
- Department of Diagnostic and Interventional Radiology, Hokkaido University Hospital, Sapporo, Hokkaido, Japan
| | - Kohsuke Kudo
- Department of Diagnostic Imaging, Hokkaido University Graduate School of Medicine, Hokkaido University, Sapporo, Hokkaido, Japan
- Global Center for Biomedical Science and Engineering, Faculty of Medicine, Hokkaido University, Sapporo, Hokkaido, Japan
| |
Collapse
|
3
|
Zhao X, Tan RS, Garg P, Chai P, Leng S, Bryant JA, Teo LLS, Yeo TJ, Fortier MV, Low TT, Ong CC, Zhang S, Van der Geest RJ, Allen JC, Tan TH, Yip JW, Tan JL, Hughes M, Plein S, Westenberg JJM, Zhong L. Age- and sex-specific reference values of biventricular flow components and kinetic energy by 4D flow cardiovascular magnetic resonance in healthy subjects. J Cardiovasc Magn Reson 2023; 25:50. [PMID: 37718441 PMCID: PMC10506211 DOI: 10.1186/s12968-023-00960-x] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/30/2023] [Accepted: 08/30/2023] [Indexed: 09/19/2023] Open
Abstract
BACKGROUND Advances in four-dimensional flow cardiovascular magnetic resonance (4D flow CMR) have allowed quantification of left ventricular (LV) and right ventricular (RV) blood flow. We aimed to (1) investigate age and sex differences of 4D flow CMR-derived LV and RV relative flow components and kinetic energy (KE) parameters indexed to end-diastolic volume (KEiEDV) in healthy subjects; and (2) assess the effects of age and sex on these parameters. METHODS We performed 4D flow analysis in 163 healthy participants (42% female; mean age 43 ± 13 years) of a prospective registry study (NCT03217240) who were free of cardiovascular diseases. Relative flow components (direct flow, retained inflow, delayed ejection flow, residual volume) and multiple phasic KEiEDV (global, peak systolic, average systolic, average diastolic, peak E-wave, peak A-wave) for both LV and RV were analysed. RESULTS Compared with men, women had lower median LV and RV residual volume, and LV peak and average systolic KEiEDV, and higher median values of RV direct flow, RV global KEiEDV, RV average diastolic KEiEDV, and RV peak E-wave KEiEDV. ANOVA analysis found there were no differences in flow components, peak and average systolic, average diastolic and global KEiEDV for both LV and RV across age groups. Peak A-wave KEiEDV increased significantly (r = 0.458 for LV and 0.341 for RV), whereas peak E-wave KEiEDV (r = - 0.355 for LV and - 0.318 for RV), and KEiEDV E/A ratio (r = - 0.475 for LV and - 0.504 for RV) decreased significantly, with age. CONCLUSION These data using state-of-the-art 4D flow CMR show that biventricular flow components and kinetic energy parameters vary significantly by age and sex. Age and sex trends should be considered in the interpretation of quantitative measures of biventricular flow. Clinical trial registration https://www. CLINICALTRIALS gov . Unique identifier: NCT03217240.
Collapse
Affiliation(s)
- Xiaodan Zhao
- National Heart Research Institute Singapore, National Heart Centre Singapore, Singapore, Singapore
| | - Ru-San Tan
- National Heart Research Institute Singapore, National Heart Centre Singapore, Singapore, Singapore
- Duke-NUS Medical School, Singapore, Singapore
- National Heart Centre Singapore, Singapore, Singapore
| | - Pankaj Garg
- Department of Cardiovascular Medicine, University of East Anglia, Norwich, UK
| | - Ping Chai
- National University Hospital Singapore, Singapore, Singapore
- Yong Loo Lin School of Medicine, National University of Singapore, Singapore, Singapore
| | - Shuang Leng
- National Heart Research Institute Singapore, National Heart Centre Singapore, Singapore, Singapore
- Duke-NUS Medical School, Singapore, Singapore
| | - Jennifer Ann Bryant
- National Heart Research Institute Singapore, National Heart Centre Singapore, Singapore, Singapore
- Duke-NUS Medical School, Singapore, Singapore
- National Heart Centre Singapore, Singapore, Singapore
| | - Lynette L S Teo
- National University Hospital Singapore, Singapore, Singapore
- Yong Loo Lin School of Medicine, National University of Singapore, Singapore, Singapore
| | - Tee Joo Yeo
- National University Hospital Singapore, Singapore, Singapore
- Yong Loo Lin School of Medicine, National University of Singapore, Singapore, Singapore
| | - Marielle V Fortier
- Duke-NUS Medical School, Singapore, Singapore
- KK Women's and Children's Hospital, Singapore, Singapore
- Singapore Institute for Clinical Sciences, A*STAR, Singapore, Singapore
| | - Ting Ting Low
- National University Hospital Singapore, Singapore, Singapore
| | - Ching Ching Ong
- National University Hospital Singapore, Singapore, Singapore
- Yong Loo Lin School of Medicine, National University of Singapore, Singapore, Singapore
| | - Shuo Zhang
- Philips Healthcare Germany, Hamburg, Germany
| | - Rob J Van der Geest
- Department of Radiology, Leiden University Medical Center, Leiden, The Netherlands
| | | | - Teng Hong Tan
- Duke-NUS Medical School, Singapore, Singapore
- KK Women's and Children's Hospital, Singapore, Singapore
| | - James W Yip
- National University Hospital Singapore, Singapore, Singapore
- Yong Loo Lin School of Medicine, National University of Singapore, Singapore, Singapore
| | - Ju Le Tan
- National Heart Research Institute Singapore, National Heart Centre Singapore, Singapore, Singapore
- Duke-NUS Medical School, Singapore, Singapore
- National Heart Centre Singapore, Singapore, Singapore
| | - Marina Hughes
- Department of Cardiovascular Medicine, University of East Anglia, Norwich, UK
| | - Sven Plein
- Leeds Institute of Cardiovascular and Metabolic Medicine, University of Leeds, Leeds, UK
| | - Jos J M Westenberg
- Department of Radiology, Leiden University Medical Center, Leiden, The Netherlands
| | - Liang Zhong
- National Heart Research Institute Singapore, National Heart Centre Singapore, Singapore, Singapore.
- Duke-NUS Medical School, Singapore, Singapore.
| |
Collapse
|
4
|
Bissell MM, Raimondi F, Ait Ali L, Allen BD, Barker AJ, Bolger A, Burris N, Carhäll CJ, Collins JD, Ebbers T, Francois CJ, Frydrychowicz A, Garg P, Geiger J, Ha H, Hennemuth A, Hope MD, Hsiao A, Johnson K, Kozerke S, Ma LE, Markl M, Martins D, Messina M, Oechtering TH, van Ooij P, Rigsby C, Rodriguez-Palomares J, Roest AAW, Roldán-Alzate A, Schnell S, Sotelo J, Stuber M, Syed AB, Töger J, van der Geest R, Westenberg J, Zhong L, Zhong Y, Wieben O, Dyverfeldt P. 4D Flow cardiovascular magnetic resonance consensus statement: 2023 update. J Cardiovasc Magn Reson 2023; 25:40. [PMID: 37474977 PMCID: PMC10357639 DOI: 10.1186/s12968-023-00942-z] [Citation(s) in RCA: 42] [Impact Index Per Article: 42.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/24/2023] [Accepted: 05/30/2023] [Indexed: 07/22/2023] Open
Abstract
Hemodynamic assessment is an integral part of the diagnosis and management of cardiovascular disease. Four-dimensional cardiovascular magnetic resonance flow imaging (4D Flow CMR) allows comprehensive and accurate assessment of flow in a single acquisition. This consensus paper is an update from the 2015 '4D Flow CMR Consensus Statement'. We elaborate on 4D Flow CMR sequence options and imaging considerations. The document aims to assist centers starting out with 4D Flow CMR of the heart and great vessels with advice on acquisition parameters, post-processing workflows and integration into clinical practice. Furthermore, we define minimum quality assurance and validation standards for clinical centers. We also address the challenges faced in quality assurance and validation in the research setting. We also include a checklist for recommended publication standards, specifically for 4D Flow CMR. Finally, we discuss the current limitations and the future of 4D Flow CMR. This updated consensus paper will further facilitate widespread adoption of 4D Flow CMR in the clinical workflow across the globe and aid consistently high-quality publication standards.
Collapse
Affiliation(s)
- Malenka M Bissell
- Department of Biomedical Imaging Science, Leeds Institute of Cardiovascular and Metabolic Medicine (LICAMM), LIGHT Laboratories, Clarendon Way, University of Leeds, Leeds, LS2 9NL, UK.
| | | | - Lamia Ait Ali
- Institute of Clinical Physiology CNR, Massa, Italy
- Foundation CNR Tuscany Region G. Monasterio, Massa, Italy
| | - Bradley D Allen
- Department of Radiology, Northwestern University Feinberg School of Medicine, Chicago, IL, USA
| | - Alex J Barker
- Department of Radiology, Children's Hospital Colorado, University of Colorado Anschutz Medical Center, Aurora, USA
| | - Ann Bolger
- Department of Medicine, University of California, San Francisco, CA, USA
- Department of Health, Medicine and Caring Sciences, Linköping University, Linköping, Sweden
| | - Nicholas Burris
- Department of Radiology, University of Michigan, Ann Arbor, USA
| | - Carl-Johan Carhäll
- Department of Health, Medicine and Caring Sciences, Linköping University, Linköping, Sweden
- Center for Medical Image Science and Visualization (CMIV), Linköping University, Linköping, Sweden
| | | | - Tino Ebbers
- Department of Health, Medicine and Caring Sciences, Linköping University, Linköping, Sweden
- Center for Medical Image Science and Visualization (CMIV), Linköping University, Linköping, Sweden
| | | | - Alex Frydrychowicz
- Department of Radiology and Nuclear Medicine, University Hospital Schleswig-Holstein, Campus Lübeck and Universität Zu Lübeck, Lübeck, Germany
| | - Pankaj Garg
- Norwich Medical School, University of East Anglia, Norwich, UK
| | - Julia Geiger
- Department of Diagnostic Imaging, University Children's Hospital, Zurich, Switzerland
- Children's Research Center, University Children's Hospital Zurich, Zurich, Switzerland
| | - Hojin Ha
- Department of Mechanical and Biomedical Engineering, Kangwon National University, Chuncheon, South Korea
| | - Anja Hennemuth
- Institute of Computer-Assisted Cardiovascular Medicine, Charité - Universitätsmedizin, Berlin, Germany
- German Center for Cardiovascular Research (DZHK), Partner Site, Berlin, Germany
- Department of Diagnostic and Interventional Radiology and Nuclear Medicine, University Medical Center Hamburg-Eppendorf, Hamburg, Germany
| | - Michael D Hope
- Department of Radiology and Biomedical Imaging, University of California, San Francisco, CA, USA
| | - Albert Hsiao
- Department of Radiology, University of California, San Diego, CA, USA
| | - Kevin Johnson
- Departments of Radiology and Medical Physics, University of Wisconsin, Madison, WI, USA
| | - Sebastian Kozerke
- Institute for Biomedical Engineering, University and ETH Zurich, Zurich, Switzerland
| | - Liliana E Ma
- Department of Radiology, Northwestern University Feinberg School of Medicine, Chicago, IL, USA
| | - Michael Markl
- Department of Radiology, Northwestern University Feinberg School of Medicine, Chicago, IL, USA
| | - Duarte Martins
- Department of Pediatric Cardiology, Hospital de Santa Cruz, Centro Hospitalar Lisboa Ocidental, Lisbon, Portugal
| | - Marci Messina
- Department of Radiology, Northwestern Medicine, Chicago, IL, USA
| | - Thekla H Oechtering
- Department of Radiology and Nuclear Medicine, University Hospital Schleswig-Holstein, Campus Lübeck and Universität Zu Lübeck, Lübeck, Germany
- Departments of Radiology and Medical Physics, University of Wisconsin, Madison, WI, USA
| | - Pim van Ooij
- Department of Radiology & Nuclear Medicine, Amsterdam Cardiovascular Sciences, Amsterdam Movement Sciences, Amsterdam University Medical Centers, Location AMC, Amsterdam, The Netherlands
- Department of Pediatric Cardiology, Division of Pediatrics, Wilhelmina Children's Hospital, University Medical Center Utrecht, Utrecht, The Netherlands
| | - Cynthia Rigsby
- Department of Radiology, Northwestern University Feinberg School of Medicine, Chicago, IL, USA
- Department of Medical Imaging, Ann & Robert H Lurie Children's Hospital of Chicago, Chicago, IL, USA
| | - Jose Rodriguez-Palomares
- Department of Cardiology, Hospital Universitari Vall d´Hebron,Vall d'Hebron Institut de Recerca (VHIR), Universitat Autònoma de Barcelona, Barcelona, Spain
- Centro de Investigación Biomédica en Red-CV, CIBER CV, Madrid, Spain
| | - Arno A W Roest
- Department of Pediatric Cardiology, Willem-Alexander's Children Hospital, Leiden University Medical Center and Center for Congenital Heart Defects Amsterdam-Leiden, Leiden, The Netherlands
| | | | - Susanne Schnell
- Department of Radiology, Northwestern University Feinberg School of Medicine, Chicago, IL, USA
- Department of Medical Physics, Institute of Physics, University of Greifswald, Greifswald, Germany
| | - Julio Sotelo
- School of Biomedical Engineering, Universidad de Valparaíso, Valparaíso, Chile
- Biomedical Imaging Center, Pontificia Universidad Catolica de Chile, Santiago, Chile
- Millennium Institute for Intelligent Healthcare Engineering - iHEALTH, Santiago, Chile
| | - Matthias Stuber
- Département de Radiologie Médicale, Centre Hospitalier Universitaire Vaudois, Lausanne, Switzerland
| | - Ali B Syed
- Department of Radiology, Stanford University, Stanford, CA, USA
| | - Johannes Töger
- Clinical Physiology, Department of Clinical Sciences Lund, Lund University, Skåne University Hospital, Lund, Sweden
| | - Rob van der Geest
- Division of Image Processing, Department of Radiology, Leiden University Medical Center, Leiden, The Netherlands
| | - Jos Westenberg
- CardioVascular Imaging Group (CVIG), Department of Radiology, Leiden University Medical Center, Leiden, The Netherlands
| | - Liang Zhong
- National Heart Centre Singapore, Duke-NUS Medical School, National University of Singapore, Singapore, Singapore
| | - Yumin Zhong
- Department of Radiology, School of Medicine, Shanghai Children's Medical Center Affiliated With Shanghai Jiao Tong University, Shanghai, People's Republic of China
| | - Oliver Wieben
- Departments of Radiology and Medical Physics, University of Wisconsin, Madison, WI, USA
| | - Petter Dyverfeldt
- Department of Health, Medicine and Caring Sciences, Linköping University, Linköping, Sweden
- Center for Medical Image Science and Visualization (CMIV), Linköping University, Linköping, Sweden
| |
Collapse
|
5
|
Evaluation of left ventricular blood flow kinetic energy in patients with hypertension by four-dimensional flow cardiovascular magnetic resonance imaging: a preliminary study. Eur Radiol 2023:10.1007/s00330-023-09449-8. [PMID: 36826498 DOI: 10.1007/s00330-023-09449-8] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/08/2022] [Revised: 01/04/2023] [Accepted: 01/18/2023] [Indexed: 02/25/2023]
Abstract
OBJECTIVES To evaluate the intra-cavity left ventricular (LV) blood flow kinetic energy (KE) parameters using four-dimensional (4D) flow cardiovascular magnetic resonance (CMR) in patients with hypertension (HTN). METHODS Forty-two HTN patients and twenty age-/gender-matched healthy controls who underwent CMR including cines, pre-/post-T1 mapping, and whole-heart 4D flow imaging were retrospectively evaluated. HTN patients were further divided into two subgroups: with preserved ejection fraction (HTN-pEF) and with reduced ejection fraction (HTN-rEF). KE parameters were indexed to LV end-diastolic volume (EDV) to obtain averaged LV, minimal, systolic, diastolic, peak E-wave, peak A-wave, E-wave, and A-wave KEiEDV, as well as the proportion of in-plane LV KE (%), the time difference (TD). These parameters were compared between the HTN group and healthy controls, also between two subgroups. The correlation of LV blood flow KE parameters with LV function and extracellular volume fraction (ECV) were analyzed in the HTN group using multivariate regression analysis. RESULTS Peak E-wave KEiEDV in the HTN group was significantly lower (p = 0.01), while in-plane KE and TD were significantly higher (all p < 0.01) than those in healthy controls. Compared to the HTN-pEF subgroup, the proportion of in-plane KE and TD was significantly increased in the HTN-rEF subgroup (all p < 0.01). Only the proportion of in-plane KE demonstrated an independent correlation with ECV (β* = 0.59, p < 0.01). CONCLUSIONS The decreased peak E-wave KEiEDV and the increased proportion of in-plane KE, TD reflected the alterations of LV blood flow in HTN patients, and the proportion of in-plane KE was independently associated with ECV. KEY POINTS • 4D flow CMR demonstrated that the peak E-wave KEiEDV was decreased, while the in-plane KE and time difference (TD) were increased in hypertensive (HTN) patients. • The proportion of in-plane KE and TD was further increased in HTN patients with reduced ejection fraction than in HTN patients with preserved ejection fraction, and the proportion of in-plane KE was independently associated with extracellular volume fraction in HTN patients. • 4D flow CMR intra-cavity blood flow KE parameters might reveal the LV hemodynamic status in preclinical HTN patients.
Collapse
|
6
|
Gorecka M, Bissell MM, Higgins DM, Garg P, Plein S, Greenwood JP. Rationale and clinical applications of 4D flow cardiovascular magnetic resonance in assessment of valvular heart disease: a comprehensive review. J Cardiovasc Magn Reson 2022; 24:49. [PMID: 35989320 PMCID: PMC9394062 DOI: 10.1186/s12968-022-00882-0] [Citation(s) in RCA: 6] [Impact Index Per Article: 3.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/09/2022] [Accepted: 08/04/2022] [Indexed: 12/03/2022] Open
Abstract
BACKGROUND Accurate evaluation of valvular pathology is crucial in the timing of surgical intervention. Whilst transthoracic echocardiography is widely available and routinely used in the assessment of valvular heart disease, it is bound by several limitations. Although cardiovascular magnetic resonance (CMR) imaging can overcome many of the challenges encountered by echocardiography, it also has a number of limitations. MAIN TEXT 4D Flow CMR is a novel technique, which allows time-resolved, 3-dimensional imaging. It enables visualisation and direct quantification of flow and peak velocities of all valves simultaneously in one simple acquisition, without any geometric assumptions. It also has the unique ability to measure advanced haemodynamic parameters such as turbulent kinetic energy, viscous energy loss rate and wall shear stress, which may add further diagnostic and prognostic information. Although 4D Flow CMR acquisition can take 5-10 min, emerging acceleration techniques can significantly reduce scan times, making 4D Flow CMR applicable in contemporary clinical practice. CONCLUSION 4D Flow CMR is an emerging CMR technique, which has the potential to become the new reference-standard method for the evaluation of valvular lesions. In this review, we describe the clinical applications, advantages and disadvantages of 4D Flow CMR in the assessment of valvular heart disease.
Collapse
Affiliation(s)
- Miroslawa Gorecka
- Leeds Institute of Cardiovascular and Metabolic Medicine, University of Leeds, Leeds, LS2 9JT, UK
| | - Malenka M Bissell
- Leeds Institute of Cardiovascular and Metabolic Medicine, University of Leeds, Leeds, LS2 9JT, UK
| | | | - Pankaj Garg
- Norwich Medical School, University of East Anglia, Norwich, UK
| | - Sven Plein
- Leeds Institute of Cardiovascular and Metabolic Medicine, University of Leeds, Leeds, LS2 9JT, UK
| | - John P Greenwood
- Leeds Institute of Cardiovascular and Metabolic Medicine, University of Leeds, Leeds, LS2 9JT, UK.
| |
Collapse
|
7
|
Abstract
This special issue of Magnetic Resonance in Medical Sciences features the most recent reviews on 4D Flow MRI. These reviews deal with the current status of the emerging technique of 4D Flow MRI facilitated in various areas that are difficult to obtain with conventional flowmetry. MR signals inherently contain flow velocity information. In previous decades, in vivo blood flow measurement was traditionally performed by 2D methods, such as Doppler ultrasonography and 2D phase-contrast MRI, which have long been regarded as mature techniques in hemodynamic flowmetry. Although 2D velocimetries have many advantages over 4D Flow MRI in terms of cost and accessibility, and provide excellent temporal and in-plane spatial resolutions, they also have some disadvantages. The emerging technology of 4D Flow MRI can overcome the shortcomings of conventional 2D imaging. In recent years, hemodynamic analysis has witnessed significant progress that is primarily attributable to advances in 4D Flow MRI.
Collapse
Affiliation(s)
- Yasuo Takehara
- Department of Fundamental Development for Low Invasive Diagnostic Imaging, Nagoya University Graduate School of Medicine
| | - Tetsuro Sekine
- Department of Radiology, Nippon Medical School Musashi Kosugi Hospital
| | - Takayuki Obata
- Applied MRI Research, Department of Molecular Imaging and Theranostics, National Institutes for Quantum Science and Technology
| |
Collapse
|