1
|
Cheng XY, Qiao PG, Jiang B, Zhang TT, He W. The application value of 3D ASL in evaluating the effectiveness of stent implantation for vertebrobasilar artery stenosis. Magn Reson Imaging 2024; 110:23-28. [PMID: 38552748 DOI: 10.1016/j.mri.2024.03.038] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/05/2024] [Revised: 03/11/2024] [Accepted: 03/25/2024] [Indexed: 04/05/2024]
Abstract
OBJECTIVE To evaluate the effect of stent implantation for vertebrobasilar artery stenosis,by using 3D arterial spin labeling (3D ASL) technique. METHODS A retrospective analysis was conducted on the clinical and 3D ASL data of 48 patients who underwent vertebral-basilar artery stenting. Post-labeling delay times (PLD) of 1.5 s and 2.5 s were chosen, and the average regional cerebral blood flow (rCBF) values were measured in nine brain regions of the posterior circulation: bilateral thalamus, bilateral occipital lobes, bilateral cerebellar hemispheres, midbrain, pons, and medulla. The 48 patients were divided into two groups based on the presence or absence of acute ischemic stroke in the posterior cerebral circulation region detected by diffusion-weighted imaging (DWI). The preoperative and postoperative rCBF results were statistically analyzed. RESULTS In the infarct group, there were significant increases in rCBF values of all nine brain regions at both PLD = 1.5 s and 2.5 s postoperatively compared to preoperatively. At PLD = 1.5 s, statistically significant differences in rCBF values between the preoperative and postoperative periods were found in the right thalamus, left cerebellum, midbrain, and pons regions (P < 0.05). At PLD = 2.5 s, statistically significant differences in rCBF values between the preoperative and postoperative periods were observed in the left occipital lobe, right cerebellum, midbrain, and pons regions (P < 0.05). When analyzing the rCBF values of the brain regions with recent infarcts in the infarct group, there was a significant increase in postoperative rCBF values compared to preoperative values (P < 0.05). After excluding the data from brain regions with recent infarcts, the CBF values in the remaining brain regions were also increased postoperatively, and some brain regions showed statistically significant differences in rCBF values between the preoperative and postoperative periods (P < 0.05). In the non-infarct group, there were no statistically significant differences in the preoperative and postoperative rCBF values in all brain regions at both PLD = 1.5 s and 2.5 s (P > 0.05). CONCLUSION The application of 3D ASL technology shows significant value in assessing the surgical efficacy of vertebral-basilar artery stenting, especially in patients with acute posterior circulation infarction.
Collapse
Affiliation(s)
- Xiao-Yue Cheng
- Department of Radiology, Beijing Friendship Hospital, Capital Medical University, Beijing 100050, China
| | - Peng-Gang Qiao
- Department of Radiology, Beijing Friendship Hospital, Capital Medical University, Beijing 100050, China.
| | - Bin Jiang
- Department of Radiology, Beijing Friendship Hospital, Capital Medical University, Beijing 100050, China
| | - Ting-Ting Zhang
- Department of Radiology, Beijing Friendship Hospital, Capital Medical University, Beijing 100050, China
| | - Wen He
- Department of Radiology, Beijing Friendship Hospital, Capital Medical University, Beijing 100050, China
| |
Collapse
|
2
|
Hoffmann E, Masthoff M, Kunz WG, Seidensticker M, Bobe S, Gerwing M, Berdel WE, Schliemann C, Faber C, Wildgruber M. Multiparametric MRI for characterization of the tumour microenvironment. Nat Rev Clin Oncol 2024; 21:428-448. [PMID: 38641651 DOI: 10.1038/s41571-024-00891-1] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Accepted: 04/04/2024] [Indexed: 04/21/2024]
Abstract
Our understanding of tumour biology has evolved over the past decades and cancer is now viewed as a complex ecosystem with interactions between various cellular and non-cellular components within the tumour microenvironment (TME) at multiple scales. However, morphological imaging remains the mainstay of tumour staging and assessment of response to therapy, and the characterization of the TME with non-invasive imaging has not yet entered routine clinical practice. By combining multiple MRI sequences, each providing different but complementary information about the TME, multiparametric MRI (mpMRI) enables non-invasive assessment of molecular and cellular features within the TME, including their spatial and temporal heterogeneity. With an increasing number of advanced MRI techniques bridging the gap between preclinical and clinical applications, mpMRI could ultimately guide the selection of treatment approaches, precisely tailored to each individual patient, tumour and therapeutic modality. In this Review, we describe the evolving role of mpMRI in the non-invasive characterization of the TME, outline its applications for cancer detection, staging and assessment of response to therapy, and discuss considerations and challenges for its use in future medical applications, including personalized integrated diagnostics.
Collapse
Affiliation(s)
- Emily Hoffmann
- Clinic of Radiology, University of Münster, Münster, Germany
| | - Max Masthoff
- Clinic of Radiology, University of Münster, Münster, Germany
| | - Wolfgang G Kunz
- Department of Radiology, University Hospital, LMU Munich, Munich, Germany
| | - Max Seidensticker
- Department of Radiology, University Hospital, LMU Munich, Munich, Germany
| | - Stefanie Bobe
- Gerhard Domagk Institute of Pathology, University Hospital Münster, Münster, Germany
| | - Mirjam Gerwing
- Clinic of Radiology, University of Münster, Münster, Germany
| | | | | | - Cornelius Faber
- Clinic of Radiology, University of Münster, Münster, Germany
| | - Moritz Wildgruber
- Department of Radiology, University Hospital, LMU Munich, Munich, Germany.
| |
Collapse
|
3
|
Jang M, Gupta A, Kovanlikaya A, Scholl JE, Zun Z. High-resolution anatomical imaging of the fetal brain with a reduced field of view using outer volume suppression. Magn Reson Med 2024. [PMID: 38702999 DOI: 10.1002/mrm.30147] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/31/2024] [Revised: 04/04/2024] [Accepted: 04/19/2024] [Indexed: 05/06/2024]
Abstract
PURPOSE To achieve high-resolution fetal brain anatomical imaging without introducing image artifacts by reducing the FOV, and to demonstrate improved image quality compared to conventional full-FOV fetal brain imaging. METHODS Reduced FOV was achieved by applying outer volume suppression (OVS) pulses immediately prior to standard single-shot fast spin echo (SSFSE) imaging. In the OVS preparation, a saturation RF pulse followed by a gradient spoiler was repeated three times with optimized flip-angle weightings and a variable spoiler scheme to enhance signal suppression. Simulations and phantom and in-vivo experiments were performed to evaluate OVS performance. In-vivo high-resolution SSFSE images acquired using the proposed approach were compared with conventional and high-resolution SSFSE images with a full FOV, using image quality scores assessed by neuroradiologists and calculated image metrics. RESULTS Excellent signal suppression in the saturation bands was confirmed in phantom and in-vivo experiments. High-resolution SSFSE images with a reduced FOV acquired using OVS demonstrated the improved depiction of brain structures without significant motion and blurring artifacts. The proposed method showed the highest image quality scores in the criteria of sharpness, contrast, and artifact and was selected as the best method based on overall image quality. The calculated image sharpness and tissue contrast ratio were also the highest with the proposed method. CONCLUSION High-resolution fetal brain anatomical images acquired using a reduced FOV with OVS demonstrated improved image quality both qualitatively and quantitatively, suggesting the potential for enhanced diagnostic accuracy in detecting fetal brain abnormalities in utero.
Collapse
Affiliation(s)
- MinJung Jang
- Department of Radiology, Weill Cornell Medicine, New York, New York, USA
| | - Ajay Gupta
- Department of Radiology, Weill Cornell Medicine, New York, New York, USA
| | - Arzu Kovanlikaya
- Department of Radiology, Weill Cornell Medicine, New York, New York, USA
| | - Jessica E Scholl
- Department of Obstetrics and Gynecology, Weill Cornell Medicine, New York, New York, USA
| | - Zungho Zun
- Department of Radiology, Weill Cornell Medicine, New York, New York, USA
| |
Collapse
|
4
|
Suzuki Y, Clement P, Dai W, Dolui S, Fernández-Seara M, Lindner T, Mutsaerts HJMM, Petr J, Shao X, Taso M, Thomas DL. ASL lexicon and reporting recommendations: A consensus report from the ISMRM Open Science Initiative for Perfusion Imaging (OSIPI). Magn Reson Med 2024; 91:1743-1760. [PMID: 37876299 PMCID: PMC10950547 DOI: 10.1002/mrm.29815] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/07/2023] [Revised: 06/22/2023] [Accepted: 07/13/2023] [Indexed: 10/26/2023]
Abstract
The 2015 consensus statement published by the International Society for Magnetic Resonance in Medicine (ISMRM) Perfusion Study Group and the European Cooperation in Science and Technology ( COST) Action ASL in Dementia aimed to encourage the implementation of robust arterial spin labeling (ASL) perfusion MRI for clinical applications and promote consistency across scanner types, sites, and studies. Subsequently, the recommended 3D pseudo-continuous ASL sequence has been implemented by most major MRI manufacturers. However, ASL remains a rapidly and widely developing field, leading inevitably to further divergence of the technique and its associated terminology, which could cause confusion and hamper research reproducibility. On behalf of the ISMRM Perfusion Study Group, and as part of the ISMRM Open Science Initiative for Perfusion Imaging (OSIPI), the ASL Lexicon Task Force has been working on the development of an ASL Lexicon and Reporting Recommendations for perfusion imaging and analysis, aiming to (1) develop standardized, consensus nomenclature and terminology for the broad range of ASL imaging techniques and parameters, as well as for the physiological constants required for quantitative analysis; and (2) provide a community-endorsed recommendation of the imaging parameters that we encourage authors to include when describing ASL methods in scientific reports/papers. In this paper, the sequences and parameters in (pseudo-)continuous ASL, pulsed ASL, velocity-selective ASL, and multi-timepoint ASL for brain perfusion imaging are included. However, the content of the lexicon is not intended to be limited to these techniques, and this paper provides the foundation for a growing online inventory that will be extended by the community as further methods and improvements are developed and established.
Collapse
Affiliation(s)
- Yuriko Suzuki
- Wellcome Centre for Integrative Neuroimaging, FMRIB, Nuffield Department of Clinical Neurosciences, University of Oxford, Oxford, UK
| | - Patricia Clement
- Department of Medical Imaging, Ghent University Hospital, Ghent, Belgium
- Department of Diagnostic Sciences, Ghent University, Ghent, Belgium
| | - Weiying Dai
- State University of New York at Binghamton, Binghamton, NY, USA
| | - Sudipto Dolui
- Department of Radiology, University of Pennsylvania, Philadelphia, USA
| | - Maria Fernández-Seara
- Department of Radiology, Clínica Universidad de Navarra, Pamplona, Spain
- IdiSNA, Instituto de Investigación Sanitaria de Navarra, Pamplona, Spain
| | | | - Henk JMM Mutsaerts
- Department of Radiology and Nuclear medicine, Amsterdam Neuroscience, Amsterdam University Medical Center, the Netherlands, Amsterdam
| | - Jan Petr
- Helmholtz-Zentrum Dresden-Rossendorf, Institute of Radiopharmaceutical Cancer Research, Dresden, Germany
| | - Xingfeng Shao
- Laboratory of FMRI Technology (LOFT), Mark & Mary Stevens Neuroimaging and Informatics Institute, Keck School of Medicine, University of Southern California, Los Angeles, California, USA
| | - Manuel Taso
- Division of MRI Research, Department of Radiology, Beth Israel Deaconess Medical Center and Harvard Medical School, Boston, Massachusetts, USA
| | - David L Thomas
- Department of Brain Repair and Rehabilitation, UCL Queen Square Institute of Neurology, University College London, London, UK
| | | |
Collapse
|
5
|
Elsaid NMH, Peters DC, Galiana G, Sinusas AJ. Clinical physiology: the crucial role of MRI in evaluation of peripheral artery disease. Am J Physiol Heart Circ Physiol 2024; 326:H1304-H1323. [PMID: 38517227 DOI: 10.1152/ajpheart.00533.2023] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 08/30/2023] [Revised: 03/19/2024] [Accepted: 03/19/2024] [Indexed: 03/23/2024]
Abstract
Peripheral artery disease (PAD) is a common vascular disease that primarily affects the lower limbs and is defined by the constriction or blockage of peripheral arteries and may involve microvascular dysfunction and tissue injury. Patients with diabetes have more prominent disease of microcirculation and develop peripheral neuropathy, autonomic dysfunction, and medial vascular calcification. Early and accurate diagnosis of PAD and disease characterization are essential for personalized management and therapy planning. Magnetic resonance imaging (MRI) provides excellent soft tissue contrast and multiplanar imaging capabilities and is useful as a noninvasive imaging tool in the comprehensive physiological assessment of PAD. This review provides an overview of the current state of the art of MRI in the evaluation and characterization of PAD, including an analysis of the many applicable MR imaging techniques, describing the advantages and disadvantages of each approach. We also present recent developments, future clinical applications, and future MRI directions in assessing PAD. The development of new MR imaging technologies and applications in preclinical models with translation to clinical research holds considerable potential for improving the understanding of the pathophysiology of PAD and clinical applications for improving diagnostic precision, risk stratification, and treatment outcomes in patients with PAD.
Collapse
Affiliation(s)
- Nahla M H Elsaid
- Department of Radiology and Biomedical Imaging, Yale University School of Medicine, New Haven, Connecticut, United States
| | - Dana C Peters
- Department of Radiology and Biomedical Imaging, Yale University School of Medicine, New Haven, Connecticut, United States
- Department of Biomedical Engineering, Yale University, New Haven, Connecticut, United States
| | - Gigi Galiana
- Department of Radiology and Biomedical Imaging, Yale University School of Medicine, New Haven, Connecticut, United States
- Department of Biomedical Engineering, Yale University, New Haven, Connecticut, United States
| | - Albert J Sinusas
- Department of Radiology and Biomedical Imaging, Yale University School of Medicine, New Haven, Connecticut, United States
- Department of Biomedical Engineering, Yale University, New Haven, Connecticut, United States
- Department of Medicine, Yale University School of Medicine, New Haven, Connecticut, United States
| |
Collapse
|
6
|
Ferreira R, Bastos-Leite AJ. Arterial spin labelling magnetic resonance imaging and perfusion patterns in neurocognitive and other mental disorders: a systematic review. Neuroradiology 2024:10.1007/s00234-024-03323-0. [PMID: 38536448 DOI: 10.1007/s00234-024-03323-0] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/01/2023] [Accepted: 02/24/2024] [Indexed: 04/18/2024]
Abstract
We reviewed 33 original research studies assessing brain perfusion, using consensus guidelines from a "white paper" issued by the International Society for Magnetic Resonance in Medicine Perfusion Study Group and the European Cooperation in Science and Technology Action BM1103 ("Arterial Spin Labelling Initiative in Dementia"; https://www.cost.eu/actions/BM1103/ ). The studies were published between 2011 and 2023 and included participants with subjective cognitive decline plus; neurocognitive disorders, including mild cognitive impairment (MCI), Alzheimer's disease (AD), frontotemporal lobar degeneration (FTLD), dementia with Lewy bodies (DLB) and vascular cognitive impairment (VCI); as well as schizophrenia spectrum disorders, bipolar and major depressive disorders, autism spectrum disorder, attention-deficit/hyperactivity disorder, panic disorder and alcohol use disorder. Hypoperfusion associated with cognitive impairment was the major finding across the spectrum of cognitive decline. Regional hyperperfusion also was reported in MCI, AD, frontotemporal dementia phenocopy syndrome and VCI. Hypoperfused structures found to aid in diagnosing AD included the precunei and adjacent posterior cingulate cortices. Hypoperfused structures found to better diagnose patients with FTLD were the anterior cingulate cortices and frontal regions. Hypoperfusion in patients with DLB was found to relatively spare the temporal lobes, even after correction for partial volume effects. Hyperperfusion in the temporal cortices and hypoperfusion in the prefrontal and anterior cingulate cortices were found in patients with schizophrenia, most of whom were on medication and at the chronic stage of illness. Infratentorial structures were found to be abnormally perfused in patients with bipolar or major depressive disorders. Brain perfusion abnormalities were helpful in diagnosing most neurocognitive disorders. Abnormalities reported in VCI and the remaining mental disorders were heterogeneous and not generalisable.
Collapse
Affiliation(s)
- Rita Ferreira
- Faculty of Medicine, University of Porto, Porto, Portugal
| | | |
Collapse
|
7
|
Zhang X, Han N, Zhang Y, Yuan W, Kan S, Zhang G, Ma H, Ge H, Du C, Gao Y, Li S, Yan X, Shi W, Tian Y, Chang M. Predicting 3-month Functional Outcome After Endovascular Thrombectomy in Patients with Anterior Circulation Occlusion with an Arterial Transit Artifact Grading System. Clin Neuroradiol 2024; 34:241-249. [PMID: 38051349 DOI: 10.1007/s00062-023-01362-3] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/05/2023] [Accepted: 10/26/2023] [Indexed: 12/07/2023]
Abstract
PURPOSE The objective of this study was to evaluate the relationship between arterial transit artifact (ATA), arterial spin labeling (ASL) perfusion imaging, and the outcome of patients with acute ischemic stroke (AIS) due to occlusion of large vessels in anterior circulation after endovascular thrombectomy (EVT). METHODS Patients with anterior circulation occlusion treated with EVT between October 2017 and December 2021 were enrolled in this retrospective study, and ATA was quantified by a 4-point scale. A favorable outcome was defined by modified Rankin Scale (mRS) scores of 0-2 at 3 months. To identify independent predictors of favorable outcome, age, sex, risk factors, baseline National Institutes of Health Stroke Scale (NIHSS) score, site of occlusion, cause of stroke, and early reperfusion were evaluated with univariate and multivariate analyses. Predictive accuracy was evaluated by calculating the area under the receiver operating characteristic (ROC) curve (AUC) for the model. RESULTS In this study 187 patients (age, 65.0 ± 12.5 years; men, 55%) were evaluated. Younger age (odds ratio, OR, 0.95; 95% confidence interval, CI, 0.92-0.98, p = 0.002), lower baseline NIHSS score (OR, 0.88; 95% CI, 0.82-0.94, p < 0.001), and lower ATA score (OR, 1.14; 95% CI, 1.06-1.22, p < 0.001) were independently associated with favorable outcomes in multivariate analysis. The ATA score has moderate to good accuracy in predicting favorable outcomes (AUC, 0.753). CONCLUSION A high ATA score as a potential predictor, can help identify patients who may benefit from EVT.
Collapse
Affiliation(s)
- Xiaobo Zhang
- The College of Life Sciences, Northwest University, Xi'an, China
- Department of Neurology, Xi'an No. 3 Hospital, The Affiliated Hospital of Northwest University, Xi'an, China
| | - Nannan Han
- Department of Neurology, Xi'an No. 3 Hospital, The Affiliated Hospital of Northwest University, Xi'an, China
| | - Yu Zhang
- The College of Life Sciences, Northwest University, Xi'an, China
| | - Wenting Yuan
- The College of Life Sciences, Northwest University, Xi'an, China
| | - Shangguang Kan
- The College of Life Sciences, Northwest University, Xi'an, China
| | - Gejuan Zhang
- Department of Neurology, Xi'an No. 3 Hospital, The Affiliated Hospital of Northwest University, Xi'an, China
| | - Haojun Ma
- Department of Neurology, Xi'an No. 3 Hospital, The Affiliated Hospital of Northwest University, Xi'an, China
| | - Hanming Ge
- Department of Neurology, Xi'an No. 3 Hospital, The Affiliated Hospital of Northwest University, Xi'an, China
| | - Chengxue Du
- Department of Neurology, Xi'an No. 3 Hospital, The Affiliated Hospital of Northwest University, Xi'an, China
| | - Yanjun Gao
- Department of Radiology, Xi'an No. 3 Hospital, The Affiliated Hospital of Northwest University, Xi'an, China
| | - Shilin Li
- Department of Neurology, Xi'an No. 3 Hospital, The Affiliated Hospital of Northwest University, Xi'an, China
| | - Xudong Yan
- Department of Neurology, Xi'an No. 3 Hospital, The Affiliated Hospital of Northwest University, Xi'an, China
| | - Wenzhen Shi
- Medical Research Center, Xi'an Key Laboratory of Cardiovascular and Cerebrovascular Diseases, Xi'an No. 3 Hospital, The Affiliated Hospital of Northwest University, Xi'an, China
| | - Ye Tian
- Department of Neurology, Xi'an No. 3 Hospital, The Affiliated Hospital of Northwest University, Xi'an, China.
- Medical Research Center, Xi'an Key Laboratory of Cardiovascular and Cerebrovascular Diseases, Xi'an No. 3 Hospital, The Affiliated Hospital of Northwest University, Xi'an, China.
| | - Mingze Chang
- Department of Neurology, Xi'an No. 3 Hospital, The Affiliated Hospital of Northwest University, Xi'an, China.
| |
Collapse
|
8
|
Dekker HM, Stroomberg GJ, Van der Molen AJ, Prokop M. Review of strategies to reduce the contamination of the water environment by gadolinium-based contrast agents. Insights Imaging 2024; 15:62. [PMID: 38411847 PMCID: PMC10899148 DOI: 10.1186/s13244-024-01626-7] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/14/2023] [Accepted: 01/19/2024] [Indexed: 02/28/2024] Open
Abstract
Gadolinium-based contrast agents (GBCA) are essential for diagnostic MRI examinations. GBCA are only used in small quantities on a per-patient basis; however, the acquisition of contrast-enhanced MRI examinations worldwide results in the use of many thousands of litres of GBCA per year. Data shows that these GBCA are present in sewage water, surface water, and drinking water in many regions of the world. Therefore, there is growing concern regarding the environmental impact of GBCA because of their ubiquitous presence in the aquatic environment. To address the problem of GBCA in the water system as a whole, collaboration is necessary between all stakeholders, including the producers of GBCA, medical professionals and importantly, the consumers of drinking water, i.e. the patients. This paper aims to make healthcare professionals aware of the opportunity to take the lead in making informed decisions about the use of GBCA and provides an overview of the different options for action.In this paper, we first provide a summary on the metabolism and clinical use of GBCA, then the environmental fate and observations of GBCA, followed by measures to reduce the use of GBCA. The environmental impact of GBCA can be reduced by (1) measures focusing on the application of GBCA by means of weight-based contrast volume reduction, GBCA with higher relaxivity per mmol of Gd, contrast-enhancing sequences, and post-processing; and (2) measures that reduce the waste of GBCA, including the use of bulk packaging and collecting residues of GBCA at the point of application.Critical relevance statement This review aims to make healthcare professionals aware of the environmental impact of GBCA and the opportunity for them to take the lead in making informed decisions about GBCA use and the different options to reduce its environmental burden.Key points• Gadolinium-based contrast agents are found in sources of drinking water and constitute an environmental risk.• Radiologists have a wide spectrum of options to reduce GBCA use without compromising diagnostic quality.• Radiology can become more sustainable by adopting such measures in clinical practice.
Collapse
Affiliation(s)
- Helena M Dekker
- Department of Medical Imaging, Radboud University Medical Center, Geert Grooteplein Zuid 10, 6525 GA, Nijmegen, The Netherlands.
| | - Gerard J Stroomberg
- RIWA-Rijn - Association of River Water Works, Groenendael 6, 3439 LV, Nieuwegein, The Netherlands
| | - Aart J Van der Molen
- Department of Radiology, Leiden University Medical Center, Albinusdreef 2, 2333 ZA, Leiden, The Netherlands
| | - Mathias Prokop
- Department of Medical Imaging, Radboud University Medical Center, Geert Grooteplein Zuid 10, 6525 GA, Nijmegen, The Netherlands
| |
Collapse
|
9
|
Taso M, Alsop DC. Arterial Spin Labeling Perfusion Imaging. Magn Reson Imaging Clin N Am 2024; 32:63-72. [PMID: 38007283 DOI: 10.1016/j.mric.2023.08.005] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/27/2023]
Abstract
Noninvasive imaging of tissue perfusion is a valuable tool for both research and clinical applications. Arterial spin labeling (ASL) is a contrast-free perfusion imaging method that enables measuring and quantifying tissue blood flow using MR imaging. ASL uses radiofrequency and magnetic field gradient pulses to label arterial blood water, which then serves as an endogenous tracer. This review highlights the basic mechanism of ASL perfusion imaging, labeling strategies, and quantification. ASL has been widely used during the past 30 years for the study of normal brain function as well as in multiple neurovascular, neuro-oncological and degenerative pathologic conditions.
Collapse
Affiliation(s)
- Manuel Taso
- Division of MRI Research, Department of Radiology, Beth Israel Deaconess Medical Center and Harvard Medical School, Boston, MA, USA
| | - David C Alsop
- Division of MRI Research, Department of Radiology, Beth Israel Deaconess Medical Center and Harvard Medical School, Boston, MA, USA.
| |
Collapse
|
10
|
Udayakumar D, Madhuranthakam AJ, Doğan BE. Magnetic Resonance Perfusion Imaging for Breast Cancer. Magn Reson Imaging Clin N Am 2024; 32:135-150. [PMID: 38007276 DOI: 10.1016/j.mric.2023.09.012] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/27/2023]
Abstract
Breast cancer is the most frequently diagnosed cancer among women worldwide, carrying a significant socioeconomic burden. Breast cancer is a heterogeneous disease with 4 major subtypes identified. Each subtype has unique prognostic factors, risks, treatment responses, and survival rates. Advances in targeted therapies have considerably improved the 5-year survival rates for primary breast cancer patients largely due to widespread screening programs that enable early detection and timely treatment. Imaging techniques are indispensable in diagnosing and managing breast cancer. While mammography is the primary screening tool, MRI plays a significant role when mammography results are inconclusive or in patients with dense breast tissue. MRI has become standard in breast cancer imaging, providing detailed anatomic and functional data, including tumor perfusion and cellularity. A key characteristic of breast tumors is angiogenesis, a biological process that promotes tumor development and growth. Increased angiogenesis in tumors generally indicates poor prognosis and increased risk of metastasis. Dynamic contrast-enhanced (DCE) MRI measures tumor perfusion and serves as an in vivo metric for angiogenesis. DCE-MRI has become the cornerstone of breast MRI, boasting a high negative-predictive value of 89% to 99%, although its specificity can vary. This review presents a thorough overview of magnetic resonance (MR) perfusion imaging in breast cancer, focusing on the role of DCE-MRI in clinical applications and exploring emerging MR perfusion imaging techniques.
Collapse
Affiliation(s)
- Durga Udayakumar
- Department of Radiology, Advanced Imaging Research Center, UT Southwestern Medical Center, Dallas, TX 75390, USA.
| | - Ananth J Madhuranthakam
- Department of Radiology, Advanced Imaging Research Center, UT Southwestern Medical Center, Dallas, TX 75390, USA
| | - Başak E Doğan
- Department of Radiology, Advanced Imaging Research Center, UT Southwestern Medical Center, Dallas, TX 75390, USA
| |
Collapse
|
11
|
Wang Y, Greer JS, Zhou L, Lin SQ, Hulsey KM, Udayakumar D, Madhuranthakam AJ. A 3D-printed phantom for quality-controlled reproducibility measurements of arterial spin labeled perfusion. Magn Reson Med 2024; 91:819-827. [PMID: 37815014 PMCID: PMC10841664 DOI: 10.1002/mrm.29886] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/06/2023] [Revised: 08/29/2023] [Accepted: 09/22/2023] [Indexed: 10/11/2023]
Abstract
PURPOSE To develop a portable MR perfusion phantom for quality-controlled assessment and reproducibility of arterial spin labeled (ASL) perfusion measurement. METHODS A 3D-printed perfusion phantom was developed that mimics the branching of arterial vessels, capillaries, and a chamber containing cellulose sponge representing tissue characteristics. A peristaltic pump circulated distilled water through the phantom, and was first evaluated at 300, 400, and 500 mL/min. Longitudinal reproducibility of perfusion was performed using 2D pseudo-continuous ASL at 20 post-label delays (PLDs, ranging between 0.2 and 7.8 s at 0.4-s intervals) over a period of 16 weeks, with three repetitions each week. Multi-PLD data were fitted into a general kinetic model for perfusion quantification (f) and arterial transit time (ATT). Intraclass correlation coefficient was used to assess intersession reproducibility. RESULTS MR perfusion signals acquired in the 3D-printed perfusion phantom agreed well with the experimental conditions, with progressively increasing signal intensities and decreasing ATT for pump flow rates from 300 to 500 mL/min. The perfusion signal at 400 mL/min and the general kinetic model-derived f and ATT maps were similar across all PLDs for both intrasession and intersession reproducibility. Across all 48 experimental time points, the average f was 75.55 ± 3.83 × 10-3 mL/mL/s, the corresponding ATT was 2.10 ± 0.20 s, and the T1 was 1.84 ± 0.102 s. Intraclass correlation coefficient was 0.92 (95% confidence interval 0.83-0.97) for f, 0.96 (0.91-0.99) for ATT, and 0.94 (0.88-0.98) for T1 , demonstrating excellent reproducibility. CONCLUSION A simple, portable 3D-printed perfusion phantom with excellent reproducibility of 2D pseudo-continuous ASL measurements was demonstrated that can serve for quality-controlled and reliable measurements of ASL perfusion.
Collapse
Affiliation(s)
- Yiming Wang
- Department of Radiology, UT Southwestern Medical Center, Dallas, Texas, USA
- Philips Healthcare, Shanghai, China
| | - Joshua S Greer
- Department of Radiology, UT Southwestern Medical Center, Dallas, Texas, USA
- Philips Healthcare, Cincinnati, Ohio, USA
| | - Limin Zhou
- Department of Radiology, UT Southwestern Medical Center, Dallas, Texas, USA
| | - Sheng-Qing Lin
- Department of Radiology, UT Southwestern Medical Center, Dallas, Texas, USA
| | - Keith M Hulsey
- Department of Radiology, UT Southwestern Medical Center, Dallas, Texas, USA
| | - Durga Udayakumar
- Department of Radiology, UT Southwestern Medical Center, Dallas, Texas, USA
- Advanced Imaging Research Center, UT Southwestern Medical Center, Dallas, Texas, USA
| | - Ananth J Madhuranthakam
- Department of Radiology, UT Southwestern Medical Center, Dallas, Texas, USA
- Advanced Imaging Research Center, UT Southwestern Medical Center, Dallas, Texas, USA
| |
Collapse
|
12
|
Bayat S, Wild J, Winkler T. Lung functional imaging. Breathe (Sheff) 2023; 19:220272. [PMID: 38020338 PMCID: PMC10644108 DOI: 10.1183/20734735.0272-2022] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/02/2023] [Accepted: 10/08/2023] [Indexed: 12/01/2023] Open
Abstract
Pulmonary functional imaging modalities such as computed tomography, magnetic resonance imaging and nuclear imaging can quantitatively assess regional lung functional parameters and their distributions. These include ventilation, perfusion, gas exchange at the microvascular level and biomechanical properties, among other variables. This review describes the rationale, strengths and limitations of the various imaging modalities employed for lung functional imaging. It also aims to explain some of the most commonly measured parameters of regional lung function. A brief review of evidence on the role and utility of lung functional imaging in early diagnosis, accurate lung functional characterisation, disease phenotyping and advancing the understanding of disease mechanisms in major respiratory disorders is provided.
Collapse
Affiliation(s)
- Sam Bayat
- Department of Pulmonology and Physiology, CHU Grenoble Alpes, Grenoble, France
- Univ. Grenoble Alpes, STROBE Laboratory, INSERM UA07, Grenoble, France
| | - Jim Wild
- POLARIS, Imaging Group, Department of Infection Immunity and Cardiovascular Disease, University of Sheffield, Sheffield, UK
- Insigneo Institute, University of Sheffield, Sheffield, UK
| | - Tilo Winkler
- Department of Anesthesia, Critical Care and Pain Medicine, Massachusetts General Hospital and Harvard Medical School, Boston, MA, USA
| |
Collapse
|
13
|
Friedli I, Baid-Agrawal S, Unwin R, Morell A, Johansson L, Hockings PD. Magnetic Resonance Imaging in Clinical Trials of Diabetic Kidney Disease. J Clin Med 2023; 12:4625. [PMID: 37510740 PMCID: PMC10380287 DOI: 10.3390/jcm12144625] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/29/2023] [Revised: 06/28/2023] [Accepted: 07/04/2023] [Indexed: 07/30/2023] Open
Abstract
Chronic kidney disease (CKD) associated with diabetes mellitus (DM) (known as diabetic kidney disease, DKD) is a serious and growing healthcare problem worldwide. In DM patients, DKD is generally diagnosed based on the presence of albuminuria and a reduced glomerular filtration rate. Diagnosis rarely includes an invasive kidney biopsy, although DKD has some characteristic histological features, and kidney fibrosis and nephron loss cause disease progression that eventually ends in kidney failure. Alternative sensitive and reliable non-invasive biomarkers are needed for DKD (and CKD in general) to improve timely diagnosis and aid disease monitoring without the need for a kidney biopsy. Such biomarkers may also serve as endpoints in clinical trials of new treatments. Non-invasive magnetic resonance imaging (MRI), particularly multiparametric MRI, may achieve these goals. In this article, we review emerging data on MRI techniques and their scientific, clinical, and economic value in DKD/CKD for diagnosis, assessment of disease pathogenesis and progression, and as potential biomarkers for clinical trial use that may also increase our understanding of the efficacy and mode(s) of action of potential DKD therapeutic interventions. We also consider how multi-site MRI studies are conducted and the challenges that should be addressed to increase wider application of MRI in DKD.
Collapse
Affiliation(s)
- Iris Friedli
- Antaros Medical, BioVenture Hub, 43183 Mölndal, Sweden
| | - Seema Baid-Agrawal
- Transplant Center, Sahlgrenska University Hospital, University of Gothenburg, 41345 Gothenburg, Sweden
| | - Robert Unwin
- AstraZeneca R&D BioPharmaceuticals, Translational Science and Experimental Medicine, Early Cardiovascular, Renal & Metabolic Diseases (CVRM), Granta Park, Cambridge CB21 6GH, UK
| | - Arvid Morell
- Antaros Medical, BioVenture Hub, 43183 Mölndal, Sweden
| | | | - Paul D Hockings
- Antaros Medical, BioVenture Hub, 43183 Mölndal, Sweden
- MedTech West, Chalmers University of Technology, 41345 Gothenburg, Sweden
| |
Collapse
|