Guo R, El-Rewaidy H, Assana S, Cai X, Amyar A, Chow K, Bi X, Yankama T, Cirillo J, Pierce P, Goddu B, Ngo L, Nezafat R. Accelerated cardiac T 1 mapping in four heartbeats with inline MyoMapNet: a deep learning-based T 1 estimation approach. J Cardiovasc Magn Reson 2022; 24:6. [PMID: 34986850 PMCID: PMC8734349 DOI: 10.1186/s12968-021-00834-0] [Citation(s) in RCA: 10] [Impact Index Per Article: 5.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/01/2021] [Accepted: 11/30/2021] [Indexed: 11/24/2022] Open
Abstract
PURPOSE To develop and evaluate MyoMapNet, a rapid myocardial T1 mapping approach that uses fully connected neural networks (FCNN) to estimate T1 values from four T1-weighted images collected after a single inversion pulse in four heartbeats (Look-Locker, LL4). METHOD We implemented an FCNN for MyoMapNet to estimate T1 values from a reduced number of T1-weighted images and corresponding inversion-recovery times. We studied MyoMapNet performance when trained using native, post-contrast T1, or a combination of both. We also explored the effects of number of T1-weighted images (four and five) for native T1. After rigorous training using in-vivo modified Look-Locker inversion recovery (MOLLI) T1 mapping data of 607 patients, MyoMapNet performance was evaluated using MOLLI T1 data from 61 patients by discarding the additional T1-weighted images. Subsequently, we implemented a prototype MyoMapNet and LL4 on a 3 T scanner. LL4 was used to collect T1 mapping data in 27 subjects with inline T1 map reconstruction by MyoMapNet. The resulting T1 values were compared to MOLLI. RESULTS MyoMapNet trained using a combination of native and post-contrast T1-weighted images had excellent native and post-contrast T1 accuracy compared to MOLLI. The FCNN model using four T1-weighted images yields similar performance compared to five T1-weighted images, suggesting that four T1 weighted images may be sufficient. The inline implementation of LL4 and MyoMapNet enables successful acquisition and reconstruction of T1 maps on the scanner. Native and post-contrast myocardium T1 by MOLLI and MyoMapNet was 1170 ± 55 ms vs. 1183 ± 57 ms (P = 0.03), and 645 ± 26 ms vs. 630 ± 30 ms (P = 0.60), and native and post-contrast blood T1 was 1820 ± 29 ms vs. 1854 ± 34 ms (P = 0.14), and 508 ± 9 ms vs. 514 ± 15 ms (P = 0.02), respectively. CONCLUSION A FCNN, trained using MOLLI data, can estimate T1 values from only four T1-weighted images. MyoMapNet enables myocardial T1 mapping in four heartbeats with similar accuracy as MOLLI with inline map reconstruction.
Collapse
Affiliation(s)
- Rui Guo
- Department of Medicine (Cardiovascular Division), Beth Israel Deaconess Medical Center and Harvard Medical School, 330 Brookline Avenue, MA, 02215, Boston, USA
| | - Hossam El-Rewaidy
- Department of Medicine (Cardiovascular Division), Beth Israel Deaconess Medical Center and Harvard Medical School, 330 Brookline Avenue, MA, 02215, Boston, USA
| | - Salah Assana
- Department of Medicine (Cardiovascular Division), Beth Israel Deaconess Medical Center and Harvard Medical School, 330 Brookline Avenue, MA, 02215, Boston, USA
| | - Xiaoying Cai
- Department of Medicine (Cardiovascular Division), Beth Israel Deaconess Medical Center and Harvard Medical School, 330 Brookline Avenue, MA, 02215, Boston, USA
- Siemens Medical Solutions USA, Inc, Boston, MA, USA
| | - Amine Amyar
- Department of Medicine (Cardiovascular Division), Beth Israel Deaconess Medical Center and Harvard Medical School, 330 Brookline Avenue, MA, 02215, Boston, USA
| | - Kelvin Chow
- Siemens Medical Solutions USA, Inc, Chicago, IL, USA
| | - Xiaoming Bi
- Siemens Medical Solutions USA, Inc, Chicago, IL, USA
| | - Tuyen Yankama
- Department of Medicine (Cardiovascular Division), Beth Israel Deaconess Medical Center and Harvard Medical School, 330 Brookline Avenue, MA, 02215, Boston, USA
| | - Julia Cirillo
- Department of Medicine (Cardiovascular Division), Beth Israel Deaconess Medical Center and Harvard Medical School, 330 Brookline Avenue, MA, 02215, Boston, USA
| | - Patrick Pierce
- Department of Medicine (Cardiovascular Division), Beth Israel Deaconess Medical Center and Harvard Medical School, 330 Brookline Avenue, MA, 02215, Boston, USA
| | - Beth Goddu
- Department of Medicine (Cardiovascular Division), Beth Israel Deaconess Medical Center and Harvard Medical School, 330 Brookline Avenue, MA, 02215, Boston, USA
| | - Long Ngo
- Department of Medicine (Cardiovascular Division), Beth Israel Deaconess Medical Center and Harvard Medical School, 330 Brookline Avenue, MA, 02215, Boston, USA
| | - Reza Nezafat
- Department of Medicine (Cardiovascular Division), Beth Israel Deaconess Medical Center and Harvard Medical School, 330 Brookline Avenue, MA, 02215, Boston, USA.
| |
Collapse
|
2
|
Charafeddine F, Refaat MM. Cardiac magnetic resonance T1 mapping for prediction of atrial fibrillation recurrence after cryoablation. PACING AND CLINICAL ELECTROPHYSIOLOGY: PACE 2019; 43:167-168. [PMID: 31808553 DOI: 10.1111/pace.13854] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Subscribe] [Scholar Register] [Received: 11/28/2019] [Accepted: 11/30/2019] [Indexed: 10/25/2022]
Affiliation(s)
- Fatme Charafeddine
- Department of Pediatrics, Division of Pediatric Cardiology, American University of Beirut Medical Center, Beirut, Lebanon
| | - Marwan M Refaat
- Department of Internal Medicine, Division of Cardiology, American University of Beirut Medical Center, Beirut, Lebanon
| |
Collapse
|
3
|
Huang L, Neji R, Nazir MS, Whitaker J, Duong P, Reid F, Bosio F, Chiribiri A, Razavi R, Roujol S. FASt single-breathhold 2D multislice myocardial T 1 mapping (FAST1) at 1.5T for full left ventricular coverage in three breathholds. J Magn Reson Imaging 2019; 51:492-504. [PMID: 31342614 PMCID: PMC6954880 DOI: 10.1002/jmri.26869] [Citation(s) in RCA: 4] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/16/2019] [Accepted: 07/02/2019] [Indexed: 12/28/2022] Open
Abstract
Background Conventional myocardial T1 mapping techniques such as modified Look–Locker inversion recovery (MOLLI) generate one T1 map per breathhold. T1 mapping with full left ventricular coverage may be desirable when spatial T1 variations are expected. This would require multiple breathholds, increasing patient discomfort and prolonging scan time. Purpose To develop and characterize a novel FASt single‐breathhold 2D multislice myocardial T1 mapping (FAST1) technique for full left ventricular coverage. Study Type Prospective. Population/Phantom Numerical simulation, agarose/NiCl2 phantom, 9 healthy volunteers, and 17 patients. Field Strength/Sequence 1.5T/FAST1. Assessment Two FAST1 approaches, FAST1‐BS and FAST1‐IR, were characterized and compared with standard 5‐(3)‐3 MOLLI in terms of accuracy, precision/spatial variability, and repeatability. Statistical Tests Kruskal‐Wallis, Wilcoxon signed rank tests, intraclass correlation coefficient analysis, analysis of variance, Student's t‐tests, Pearson correlation analysis, and Bland–Altman analysis. Results In simulation/phantom, FAST1‐BS, FAST1‐IR, and MOLLI had an accuracy (expressed as T1 error) of 0.2%/4%, 6%/9%, and 4%/7%, respectively, while FAST1‐BS and FAST1‐IR had a precision penalty of 1.7/1.5 and 1.5/1.4 in comparison with MOLLI, respectively. In healthy volunteers, FAST1‐BS/FAST1‐IR/MOLLI led to different native myocardial T1 times (1016 ± 27 msec/952 ±22 msec/987 ± 23 msec, P < 0.0001) and spatial variability (66 ± 10 msec/57 ± 8 msec/46 ± 7 msec, P < 0.001). There were no statistically significant differences between all techniques for T1 repeatability (P = 0.18). In vivo native and postcontrast myocardial T1 times in both healthy volunteers and patients using FAST1‐BS/FAST1‐IR were highly correlated with MOLLI (Pearson correlation coefficient ≥0.93). Data Conclusion FAST1 enables myocardial T1 mapping with full left ventricular coverage in three separated breathholds. In comparison with MOLLI, FAST1 yield a 5‐fold increase of spatial coverage, limited penalty of T1 precision/spatial variability, no significant difference of T1 repeatability, and highly correlated T1 times. FAST1‐IR provides improved T1 precision/spatial variability but reduced accuracy when compared with FAST1‐BS. Level of Evidence: 1 Technical Efficacy: Stage 3 J. Magn. Reson. Imaging 2020;51:492–504.
Collapse
Affiliation(s)
- Li Huang
- The School of Biomedical Engineering and Imaging Sciences, Faculty of Life Sciences and Medicine, King's College London, London, UK
| | - Radhouene Neji
- The School of Biomedical Engineering and Imaging Sciences, Faculty of Life Sciences and Medicine, King's College London, London, UK.,MR Research Collaborations, Siemens Healthcare Limited, Frimley, UK
| | - Muhummad Sohaib Nazir
- The School of Biomedical Engineering and Imaging Sciences, Faculty of Life Sciences and Medicine, King's College London, London, UK
| | - John Whitaker
- The School of Biomedical Engineering and Imaging Sciences, Faculty of Life Sciences and Medicine, King's College London, London, UK
| | - Phuoc Duong
- The School of Biomedical Engineering and Imaging Sciences, Faculty of Life Sciences and Medicine, King's College London, London, UK
| | - Fiona Reid
- School of Population Health and Environmental Sciences, Faculty of Life Sciences and Medicine, King's College London, London, UK
| | - Filippo Bosio
- The School of Biomedical Engineering and Imaging Sciences, Faculty of Life Sciences and Medicine, King's College London, London, UK
| | - Amedeo Chiribiri
- The School of Biomedical Engineering and Imaging Sciences, Faculty of Life Sciences and Medicine, King's College London, London, UK
| | - Reza Razavi
- The School of Biomedical Engineering and Imaging Sciences, Faculty of Life Sciences and Medicine, King's College London, London, UK
| | - Sébastien Roujol
- The School of Biomedical Engineering and Imaging Sciences, Faculty of Life Sciences and Medicine, King's College London, London, UK
| |
Collapse
|
4
|
Huang L, Neji R, Nazir MS, Whitaker J, Reid F, Bosio F, Chiribiri A, Razavi R, Roujol S. Fast myocardial T 1 mapping using shortened inversion recovery based schemes. J Magn Reson Imaging 2019; 50:641-654. [PMID: 30672041 PMCID: PMC6751084 DOI: 10.1002/jmri.26649] [Citation(s) in RCA: 7] [Impact Index Per Article: 1.4] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/17/2018] [Revised: 12/26/2018] [Accepted: 12/27/2018] [Indexed: 11/18/2022] Open
Abstract
Background Myocardial T1 mapping shows promise for assessment of cardiomyopathies. Most myocardial T1 mapping techniques, such as modified Look–Locker inversion recovery (MOLLI), generate one T1 map per breath‐held acquisition (9–17 heartbeats), which prolongs multislice protocols and may be unsuitable for patients with breath‐holding difficulties. Purpose To develop and characterize novel shortened inversion recovery based T1 mapping schemes of 2–5 heartbeats. Study Type Prospective. Population/Phantom Numerical simulations, agarose/NiCl2 phantom, 16 healthy volunteers, and 24 patients. Field Strength/Sequence 1.5T/MOLLI. Assessment All shortened T1 mapping schemes were characterized and compared with a conventional MOLLI scheme (5‐(3)‐3) in terms of accuracy, precision, spatial variability, and repeatability. Statistical Tests Kruskal–Wallis, Wilcoxon rank sum tests, analysis of variance, Student's t‐tests, Bland–Altman analysis, and Pearson correlation analysis. Results All shortened schemes provided limited T1 time variations (≤2% for T1 times ≤1200 msec) and limited penalty of precision (by a factor of ~1.4–1.5) when compared with MOLLI in numerical simulations. In phantom, differences between all schemes in terms of accuracy, spatial variability, and repeatability did not reach statistical significance (P > 0.71). In healthy volunteers, there were no statistically significant differences between all schemes in terms of native T1 times and repeatability for myocardium (P = 0.21 and P = 0.87, respectively) and blood (P = 0.79 and P = 0.41, respectively). All shortened schemes led to a limited increase of spatial variability for native myocardial T1 mapping with respect to MOLLI (by a factor of 1.2) (P < 0.0001). In both healthy volunteers and patients, the two‐heartbeat scheme and MOLLI led to highly linearly correlated T1 times (correlation coefficients ≥0.83). Data Conclusion The proposed two‐heartbeat T1 mapping scheme yields a 5‐fold acceleration compared with MOLLI, with highly linearly correlated T1 times, no significant difference of repeatability, and limited spatial variability penalty at 1.5T. This approach may enable myocardial T1 mapping in patients with severe breath‐holding difficulties and reduce the examination time of multislice protocols. Level of Evidence: 1 Technical Efficacy Stage: 3 J. Magn. Reson. Imaging 2019;50:641–654.
Collapse
Affiliation(s)
- Li Huang
- School of Biomedical Engineering and Imaging Sciences, Faculty of Life Sciences and Medicine, King's College London, United Kingdom
| | - Radhouene Neji
- School of Biomedical Engineering and Imaging Sciences, Faculty of Life Sciences and Medicine, King's College London, United Kingdom.,MR Research Collaborations, Siemens Healthcare Limited, Frimley, United Kingdom
| | - Muhummad Sohaib Nazir
- School of Biomedical Engineering and Imaging Sciences, Faculty of Life Sciences and Medicine, King's College London, United Kingdom
| | - John Whitaker
- School of Biomedical Engineering and Imaging Sciences, Faculty of Life Sciences and Medicine, King's College London, United Kingdom
| | - Fiona Reid
- School of Population Health and Environmental Sciences, Faculty of Life Sciences and Medicine, King's College London, United Kingdom
| | - Filippo Bosio
- School of Biomedical Engineering and Imaging Sciences, Faculty of Life Sciences and Medicine, King's College London, United Kingdom
| | - Amedeo Chiribiri
- School of Biomedical Engineering and Imaging Sciences, Faculty of Life Sciences and Medicine, King's College London, United Kingdom
| | - Reza Razavi
- School of Biomedical Engineering and Imaging Sciences, Faculty of Life Sciences and Medicine, King's College London, United Kingdom
| | - Sébastien Roujol
- School of Biomedical Engineering and Imaging Sciences, Faculty of Life Sciences and Medicine, King's College London, United Kingdom
| |
Collapse
|
5
|
Evaluation of Modified Look-Locker Inversion Recovery and Arrhythmia-Insensitive Rapid Cardiac T1 Mapping Pulse Sequences in Cardiomyopathy Patients. J Comput Assist Tomogr 2018; 42:732-738. [PMID: 29613994 DOI: 10.1097/rct.0000000000000746] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/19/2023]
Abstract
OBJECTIVE The aim of this study was to compare the performance of arrhythmia-insensitive rapid (AIR) and modified Look-Locker inversion recovery (MOLLI) T1 mapping in patients with cardiomyopathies. METHODS In 58 patients referred for clinical cardiac magnetic resonance imaging at 1.5 T, we compared MOLLI and AIR native and postcontrast T1 measurements. Two readers independently analyzed myocardial and blood T1 values. Agreement between techniques, interreader agreement per technique, and intrascan agreement per technique were evaluated. RESULTS The MOLLI and AIR T1 values were strongly correlated (r = 0.98); however, statistically significantly different T1 values were derived (bias 80 milliseconds, pooled data, P < 0.01). Both techniques demonstrated high repeatability (MOLLI, r = 1.00 and coefficient of repeatability [CR] = 72 milliseconds; AIR, r = 0.99 and CR = 184.2 milliseconds) and produced high interreader agreement (MOLLI, r = 1.00 and CR = 51.7 milliseconds; AIR, r = 0.99 and CR = 183.5 milliseconds). CONCLUSIONS Arrhythmia-insensitive rapid and MOLLI sequences produced significantly different T1 values in a diverse patient cohort.
Collapse
|
6
|
Weingärtner S, Meßner NM, Budjan J, Loßnitzer D, Mattler U, Papavassiliu T, Zöllner FG, Schad LR. Myocardial T 1-mapping at 3T using saturation-recovery: reference values, precision and comparison with MOLLI. J Cardiovasc Magn Reson 2016; 18:84. [PMID: 27855705 PMCID: PMC5114738 DOI: 10.1186/s12968-016-0302-x] [Citation(s) in RCA: 65] [Impact Index Per Article: 8.1] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/17/2016] [Accepted: 11/01/2016] [Indexed: 11/10/2022] Open
Abstract
BACKGROUND Myocardial T1-mapping recently emerged as a promising quantitative method for non-invasive tissue characterization in numerous cardiomyopathies. Commonly performed with an inversion-recovery (IR) magnetization preparation at 1.5T, the application at 3T has gained due to increased quantification precision. Alternatively, saturation-recovery (SR) T1-mapping has recently been introduced at 1.5T for improved accuracy. Thus, the purpose of this study is to investigate the robustness and precision of SR T1-mapping at 3T and to establish accurate reference values for native T1-times and extracellular volume fraction (ECV) of healthy myocardium. METHODS Balanced Steady-State Free-Precession (bSSFP) Saturation-Pulse Prepared Heart-rate independent Inversion-REcovery (SAPPHIRE) and Saturation-recovery Single-SHot Acquisition (SASHA) T1-mapping were compared with the Modified Look-Locker inversion recovery (MOLLI) sequence at 3T. Accuracy and precision were studied in phantom. Native and post-contrast T1-times and regional ECV were determined in 20 healthy subjects (10 men, 27 ± 5 years). Subjective image quality, susceptibility artifact rating, in-vivo precision and reproducibility were analyzed. RESULTS SR T1-mapping showed <4 % deviation from the spin-echo reference in phantom in the range of T1 = 100-2300 ms. The average quality and artifact scores of the T1-mapping methods were: MOLLI:3.4/3.6, SAPPHIRE:3.1/3.4, SASHA:2.9/3.2; (1: poor - 4: excellent/1: strong - 4: none). SAPPHIRE and SASHA yielded significantly higher T1-times (SAPPHIRE: 1578 ± 42 ms, SASHA: 1523 ± 46 ms), in-vivo T1-time variation (SAPPHIRE: 60.1 ± 8.7 ms, SASHA: 70.0 ± 9.3 ms) and lower ECV-values (SAPPHIRE: 0.20 ± 0.02, SASHA: 0.21 ± 0.03) compared with MOLLI (T1: 1181 ± 47 ms, ECV: 0.26 ± 0.03, Precision: 53.7 ± 8.1 ms). No significant difference was found in the inter-subject variability of T1-times or ECV-values (T1: p = 0.90, ECV: p = 0.78), the observer agreement (inter: p > 0.19; intra: p > 0.09) or consistency (inter: p > 0.07; intra: p > 0.17) between the three methods. CONCLUSIONS Saturation-recovery T1-mapping at 3T yields higher accuracy, comparable inter-subject, inter- and intra-observer variability and less than 30 % precision-loss compared to MOLLI.
Collapse
Affiliation(s)
- Sebastian Weingärtner
- Computer Assisted Clinical Medicine, University Medical Center Mannheim, Medical Faculty Mannheim, Heidelberg University, Theodor-Kutzer-Ufer 1-3, 68167 Mannheim, Germany
- Electrical and Computer Engineering, University of Minnesota, Minneapolis, MN USA
- Center for Magnetic Resonance Research, University of Minnesota, Minneapolis, MN USA
| | - Nadja M. Meßner
- Computer Assisted Clinical Medicine, University Medical Center Mannheim, Medical Faculty Mannheim, Heidelberg University, Theodor-Kutzer-Ufer 1-3, 68167 Mannheim, Germany
- DZHK (German Centre for Cardiovascular Research) partner site Heidelberg/Mannheim, Mannheim, Germany
| | - Johannes Budjan
- Institute of Clinical Radiology and Nuclear Medicine, University Medical Center Mannheim, Medical Faculty Mannheim, Heidelberg University, Mannheim, Germany
| | - Dirk Loßnitzer
- 1st Department of Medicine Cardiology, University Medical Center Mannheim, Medical Faculty Mannheim, Heidelberg University, Mannheim, Germany
| | - Uwe Mattler
- Institute of Clinical Radiology and Nuclear Medicine, University Medical Center Mannheim, Medical Faculty Mannheim, Heidelberg University, Mannheim, Germany
| | - Theano Papavassiliu
- DZHK (German Centre for Cardiovascular Research) partner site Heidelberg/Mannheim, Mannheim, Germany
- 1st Department of Medicine Cardiology, University Medical Center Mannheim, Medical Faculty Mannheim, Heidelberg University, Mannheim, Germany
| | - Frank G. Zöllner
- Computer Assisted Clinical Medicine, University Medical Center Mannheim, Medical Faculty Mannheim, Heidelberg University, Theodor-Kutzer-Ufer 1-3, 68167 Mannheim, Germany
| | - Lothar R. Schad
- Computer Assisted Clinical Medicine, University Medical Center Mannheim, Medical Faculty Mannheim, Heidelberg University, Theodor-Kutzer-Ufer 1-3, 68167 Mannheim, Germany
| |
Collapse
|
7
|
Hong K, Collins J, Lee DC, Wilcox JE, Markl M, Carr J, Kim D. Optimized AIR and investigational MOLLI cardiac T1 mapping pulse sequences produce similar intra-scan repeatability in patients at 3T. NMR IN BIOMEDICINE 2016; 29:1454-63. [PMID: 27593977 PMCID: PMC5065359 DOI: 10.1002/nbm.3597] [Citation(s) in RCA: 7] [Impact Index Per Article: 0.9] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 04/20/2016] [Revised: 07/11/2016] [Accepted: 07/13/2016] [Indexed: 05/18/2023]
Abstract
This study was conducted to improve the precision of arrhythmia-insensitive rapid (AIR) cardiac T1 mapping through pulse sequence optimization and then evaluate the intra-scan repeatability in patients at 3T against investigational modified Look-Locker inversion recovery (MOLLI) T1 mapping. In the first development phase (five human subjects), we implemented and tested centric-pair k-space ordering to suppress image artifacts associated with eddy currents. In the second development phase (15 human subjects), we determined optimal flip angles to reduce the measurement variation in T1 maps. In the validation phase (35 patients), we compared the intra-scan repeatability between investigational MOLLI and optimized AIR. In 23 cardiac planes, conventional centric k-space ordering (3.7%) produced significantly (p < 0.05) more outliers as a fraction of left ventricular cavity area than optimal centric k-space ordering (1.4%). In 15 human subjects, for each of four types of measurement (native myocardial T1 , native blood T1 , post-contrast myocardial T1 , post-contrast blood T1 ), flip angles of 55-65° produced lower measurement variation while producing results that are not significantly different from those produced with the previously used flip angle of 35° (p > 0.89, intra-class correlation coefficient ≥ 0.95 for all four measurement types). Compared with investigational MOLLI (coefficient of repeatability, CR = 40.0, 77.2, 26.5, and 25.9 ms for native myocardial, native blood, post-contrast myocardial, and post-contrast blood T1 , and 2.0% for extracellular volume (ECV) measurements, respectively), optimized AIR (CR = 54.3, 89.7, 30.5, and 14.7 ms for native myocardial, native blood, post-contrast myocardial, and post-contrast blood T1 , and 1.6% for ECV measurements, respectively) produced similar absolute intra-scan repeatability in all 35 patients in the validation phase. High repeatability is critically important for longitudinal studies, where the goal is to monitor physiologic/pathologic changes, not measurement variation. Optimized AIR cardiac T1 mapping is likely to yield high scan-retest repeatability for pre-clinical and clinical applications.
Collapse
Affiliation(s)
- KyungPyo Hong
- Department of Bioengineering, University of Utah, Salt Lake City, UT, 84112, USA
- UCAIR, Department of Radiology, University of Utah, Salt Lake City, UT, 84108, USA
| | - Jeremy Collins
- Department of Radiology, Northwestern University, Chicago, IL, 60611, USA
| | - Daniel C Lee
- Department of Radiology, Northwestern University, Chicago, IL, 60611, USA
- Division of Cardiology, Internal Medicine, Northwestern University, Chicago, IL, 60611, USA
| | - Jane E Wilcox
- Division of Cardiology, Internal Medicine, Northwestern University, Chicago, IL, 60611, USA
| | - Michael Markl
- Department of Radiology, Northwestern University, Chicago, IL, 60611, USA
- Department of Biomedical Engineering, Northwestern University, Chicago, IL, 60208, USA
| | - James Carr
- Department of Radiology, Northwestern University, Chicago, IL, 60611, USA
| | - Daniel Kim
- UCAIR, Department of Radiology, University of Utah, Salt Lake City, UT, 84108, USA.
- Department of Radiology, Northwestern University, Chicago, IL, 60611, USA.
| |
Collapse
|
8
|
Selection of magnetization catalyzation and readout methods for modified Look-Locker inversion recovery: a T1 mapping primer. Magn Reson Imaging 2015; 33:363-73. [PMID: 25660643 DOI: 10.1016/j.mri.2015.02.004] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/20/2014] [Revised: 01/15/2015] [Accepted: 02/01/2015] [Indexed: 01/13/2023]
Abstract
BACKGROUND The purpose of this work was to evaluate different magnetization preparation and readout sequences for modified Look-Locker inversion recovery (MOLLI) toward improved T1 mapping in the heart. Elements investigated include: catalyzation sequences to prepare the magnetization before readout, alternate k-space trajectories, a spoiled gradient recalled echo readout, and a 5b(3b)3b MOLLI sampling scheme ('b' denoting beats). METHODS Conventional 3b(3b)3b(3b)5b MOLLI with a linear k-space trajectory was compared to four variants in simulations, in vitro and in vivo (at 3T). Variants were centric conventional MOLLI, centric-paired conventional MOLLI, linear 5b(3b)3b MOLLI and spoiled gradient recalled echo MOLLI. Each of these was applied with three magnetization catalyzation methods, and T1 measurement accuracy and precision were evaluated in simulations via a Monte Carlo algorithm, in a set of calibrated phantoms, and in ten healthy volunteers. Contrast-to-noise, heart rate dependence and B1+ dependence were also evaluated. RESULTS A linear k-space trajectory was superior in vitro to centric and centric-paired trajectories. Of the catalyzation methods, preparation of transverse magnetization only-using a linearly increasing flip angle catalyzation-improved MOLLI T1 measurement accuracy, precision, and map quality versus methods that include catalyzation of the longitudinal magnetization. The 5b(3b)3b MOLLI scheme offered comparable native T1 measurement accuracy and precision to conventional MOLLI, despite its shortened acquisition. CONCLUSIONS MOLLI T1 measurement accuracy, precision, and map quality depend on the method of catalyzation of magnetization prior to image acquisition, as well as on the readout method and MOLLI sampling scheme used.
Collapse
|