Jogi SP, Peng Q, Jafari R, Otazo R, Wu C. Novel spin-lock time sampling strategies for improved reproducibility in quantitative T1ρ mapping. NMR IN BIOMEDICINE 2024; 37:e5244. [PMID: 39152756 DOI: 10.1002/nbm.5244] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 04/02/2024] [Revised: 07/12/2024] [Accepted: 08/05/2024] [Indexed: 08/19/2024]
Abstract
This study aimed to optimize the sampling of spin-lock times (TSLs) in quantitative T1ρ mapping for improved reproducibility. Two new TSL sampling schemes were proposed: (i) reproducibility-guided random sampling (RRS) and (ii) reproducibility-guided optimal sampling (ROS). They were compared to the existing linear sampling (LS) and precision-guided sampling (PS) schemes for T1ρ reproducibility through numerical simulations, phantom experiments, and volunteer studies. Each study evaluated the four sampling schemes with three commonly used T1ρ preparations based on composite and balanced spin-locking. Additionally, the phantom and volunteer studies investigated the impact of B0 and B1 field inhomogeneities on T1ρ reproducibility, respectively. The reproducibility was assessed using the coefficient of variation (CoV) by repeating the T1ρ measurements eight times for phantom experiments and five times for volunteer studies. Numerical simulations resulted in lower mean CoVs for the proposed RRS (1.74%) and ROS (0.68%) compared to LS (2.93%) and PS (3.68%). In the phantom study, the mean CoVs were also lower for RRS (2.7%) and ROS (2.6%) compared to LS (4.1%) and PS (3.1%). Furthermore, the mean CoVs of the proposed RRS and ROS were statistically lower (P < 0.001) compared to existing LS and PS schemes at a B1 offset of 20%. In the volunteer study, consistently lower mean CoVs were observed in bilateral thigh muscles for RRS (9.3%) and ROS (9.2%) compared to LS (10.9%) and PS (10.2%), and the difference was more prominent at B0 offsets higher than 50 Hz. The proposed sampling schemes improve the reproducibility of quantitative T1ρ mapping by optimizing the selection of TSLs. This improvement is especially beneficial for longitudinal studies that track and monitor disease progression and treatment response.
Collapse
Affiliation(s)
- Sandeep Panwar Jogi
- Department of Medical Physics, Memorial Sloan Kettering Cancer Center, New York, New York, USA
| | - Qi Peng
- Department of Radiology, Albert Einstein College of Medicine and Montefiore Medical Center, Bronx, New York, USA
| | - Ramin Jafari
- Philips Healthcare, MR Clinical Science, Cambridge, Massachusetts, USA
| | - Ricardo Otazo
- Department of Medical Physics, Memorial Sloan Kettering Cancer Center, New York, New York, USA
- Department of Radiology, Memorial Sloan Kettering Cancer Center, New York, New York, USA
| | - Can Wu
- Department of Medical Physics, Memorial Sloan Kettering Cancer Center, New York, New York, USA
| |
Collapse
|
2
|
Wang L, Wang X, Jiang F, Cao Y, Liu S, Chen H, Yang J, Zhang X, Yu T, Xu H, Lin M, Wu Y, Zhang J. Adding quantitative T1rho-weighted imaging to conventional MRI improves specificity and sensitivity for differentiating malignant from benign breast lesions. Magn Reson Imaging 2024; 108:98-103. [PMID: 38331054 DOI: 10.1016/j.mri.2024.02.005] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/13/2023] [Revised: 02/02/2024] [Accepted: 02/05/2024] [Indexed: 02/10/2024]
Abstract
OBJECTIVES To investigate the feasibility of T1rho-weighted imaging in differentiating malignant from benign breast lesions and to explore the additional value of T1rho to conventional MRI. MATERIALS AND METHODS We prospectively enrolled consecutive women with breast lesions who underwent preoperative T1rho-weighted imaging, diffusion-weighted imaging, and dynamic contrast-enhanced magnetic resonance imaging (DCE-MRI) between November 2021 and July 2023. The T1rho, apparent diffusion coefficient (ADC), and semi-quantitative parameters from DCE-MRI were obtained and compared between benign and malignant groups. The diagnostic performance was analyzed and compared using receiver operating characteristic (ROC) curves and the Delong Test. RESULTS This study included 113 patients (74 malignant and 39 benign lesions). The mean T1rho value in the benign group (92.61 ± 22.10 ms) was significantly higher than that in the malignant group (72.18 ± 16.37 ms) (P < 0.001). The ADC value and time to peak (TTP) value in the malignant group (1.13 ± 0.45 and 269.06 ± 106.01, respectively) were lower than those in the benign group (1.57 ± 0.45 and 388.30 ± 81.13, respectively) (all P < 0.001). T1rho combined with ADC and TTP showed good diagnostic performance with an area under the curve (AUC) of 0.896, a sensitivity of 81.0%, and a specificity of 87.1%. The specificity and sensitivity of the combination of T1rho, ADC, and TTP were significantly higher than those of the combination of ADC and TTP (87.1% vs. 84.6%, P < 0.005; 81.0% vs. 77.0%, P < 0.001). CONCLUSION T1rho-weighted imaging was a feasible MRI sequence for differentiating malignant from benign breast lesions. The combination of T1rho, ADC and TTP could achieve a favorable diagnostic performance with improved specificity and sensitivity, T1rho could serve as a supplementary approach to conventional MRI.
Collapse
Affiliation(s)
- Lu Wang
- Department of Radiology, Chongqing University Cancer Hospital, Chongqing Key Laboratory for Intelligent Oncology in Breast Cancer (iCQBC), Chongqing 400030, China
| | - Xiaoxia Wang
- Department of Radiology, Chongqing University Cancer Hospital, Chongqing Key Laboratory for Intelligent Oncology in Breast Cancer (iCQBC), Chongqing 400030, China
| | - Fujie Jiang
- Department of Radiology, Chongqing University Cancer Hospital, Chongqing Key Laboratory for Intelligent Oncology in Breast Cancer (iCQBC), Chongqing 400030, China
| | - Ying Cao
- School of Medicine, Chongqing University, Chongqing 400030, China
| | - Shuling Liu
- Department of Radiology, Chongqing University Cancer Hospital, Chongqing Key Laboratory for Intelligent Oncology in Breast Cancer (iCQBC), Chongqing 400030, China
| | - Huifang Chen
- Department of Radiology, Chongqing University Cancer Hospital, Chongqing Key Laboratory for Intelligent Oncology in Breast Cancer (iCQBC), Chongqing 400030, China
| | - Jing Yang
- Department of Radiology, Chongqing University Cancer Hospital, Chongqing Key Laboratory for Intelligent Oncology in Breast Cancer (iCQBC), Chongqing 400030, China
| | | | - Tao Yu
- Department of Radiology, Chongqing University Cancer Hospital, Chongqing Key Laboratory for Intelligent Oncology in Breast Cancer (iCQBC), Chongqing 400030, China
| | - Hanshan Xu
- Department of Radiology, Chongqing University Cancer Hospital, Chongqing Key Laboratory for Intelligent Oncology in Breast Cancer (iCQBC), Chongqing 400030, China
| | - Meng Lin
- Department of Radiology, Chongqing University Cancer Hospital, Chongqing Key Laboratory for Intelligent Oncology in Breast Cancer (iCQBC), Chongqing 400030, China
| | - Yongzhong Wu
- Radiation Oncology Center, Chongqing University, Chongqing 400030, China
| | - Jiuquan Zhang
- Department of Radiology, Chongqing University Cancer Hospital, Chongqing Key Laboratory for Intelligent Oncology in Breast Cancer (iCQBC), Chongqing 400030, China.
| |
Collapse
|
3
|
Bustin A, Witschey WRT, van Heeswijk RB, Cochet H, Stuber M. Magnetic resonance myocardial T1ρ mapping : Technical overview, challenges, emerging developments, and clinical applications. J Cardiovasc Magn Reson 2023; 25:34. [PMID: 37331930 DOI: 10.1186/s12968-023-00940-1] [Citation(s) in RCA: 4] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/18/2022] [Accepted: 05/15/2023] [Indexed: 06/20/2023] Open
Abstract
The potential of cardiac magnetic resonance to improve cardiovascular care and patient management is considerable. Myocardial T1-rho (T1ρ) mapping, in particular, has emerged as a promising biomarker for quantifying myocardial injuries without exogenous contrast agents. Its potential as a contrast-agent-free ("needle-free") and cost-effective diagnostic marker promises high impact both in terms of clinical outcomes and patient comfort. However, myocardial T1ρ mapping is still at a nascent stage of development and the evidence supporting its diagnostic performance and clinical effectiveness is scant, though likely to change with technological improvements. The present review aims at providing a primer on the essentials of myocardial T1ρ mapping, and to describe the current range of clinical applications of the technique to detect and quantify myocardial injuries. We also delineate the important limitations and challenges for clinical deployment, including the urgent need for standardization, the evaluation of bias, and the critical importance of clinical testing. We conclude by outlining technical developments to be expected in the future. If needle-free myocardial T1ρ mapping is shown to improve patient diagnosis and prognosis, and can be effectively integrated in cardiovascular practice, it will fulfill its potential as an essential component of a cardiac magnetic resonance examination.
Collapse
Affiliation(s)
- Aurelien Bustin
- IHU LIRYC, Electrophysiology and Heart Modeling Institute, Université de Bordeaux, INSERM, Centre de Recherche Cardio-Thoracique de Bordeaux, U1045, Avenue du Haut Lévêque, 33604, Pessac, France.
- Department of Cardiovascular Imaging, Hôpital Cardiologique du Haut-Lévêque, CHU de Bordeaux, Avenue de Magellan, 33604, Pessac, France.
- Department of Diagnostic and Interventional Radiology, Lausanne University Hospital and University of Lausanne, Lausanne, Switzerland.
| | | | - Ruud B van Heeswijk
- Department of Diagnostic and Interventional Radiology, Lausanne University Hospital and University of Lausanne, Lausanne, Switzerland
| | - Hubert Cochet
- IHU LIRYC, Electrophysiology and Heart Modeling Institute, Université de Bordeaux, INSERM, Centre de Recherche Cardio-Thoracique de Bordeaux, U1045, Avenue du Haut Lévêque, 33604, Pessac, France
- Department of Cardiovascular Imaging, Hôpital Cardiologique du Haut-Lévêque, CHU de Bordeaux, Avenue de Magellan, 33604, Pessac, France
| | - Matthias Stuber
- IHU LIRYC, Electrophysiology and Heart Modeling Institute, Université de Bordeaux, INSERM, Centre de Recherche Cardio-Thoracique de Bordeaux, U1045, Avenue du Haut Lévêque, 33604, Pessac, France
- Department of Diagnostic and Interventional Radiology, Lausanne University Hospital and University of Lausanne, Lausanne, Switzerland
- Center for Biomedical Imaging (CIBM), Lausanne, Switzerland
| |
Collapse
|
4
|
Yang Y, Wang C, Liu Y, Chen Z, Liu X, Zheng H, Liang D, Zhu Y. A robust adiabatic constant amplitude spin-lock preparation module for myocardial T 1ρ quantification at 3 T. NMR IN BIOMEDICINE 2023; 36:e4830. [PMID: 36093600 DOI: 10.1002/nbm.4830] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 05/14/2022] [Revised: 08/25/2022] [Accepted: 09/08/2022] [Indexed: 06/15/2023]
Abstract
T1ρ quantification has the potential to assess myocardial fibrosis without contrast agent. However, its preparation spin-lock pulse is sensitive to B1 and B0 inhomogeneities, resulting in severe banding artifacts in the heart region, especially at high magnetic field such as 3 T. We aimed to design a robust spin-lock (SL) preparation module that can be used in myocardial T1ρ quantification at 3 T. We used the tan/tanh pulse to tip up and tip down the magnetization in the spin-lock preparation module (tan/tanh-SL). Bloch simulation was used to optimize pulse shape parameters of the tan/tanh with a pulse duration (Tp ) of 8, 4, and 2 ms, respectively. The designed tan/tanh-SL modules were implemented on a 3-T MR scanner. They were evaluated in phantom studies under three different cases of B0 and B1 inhomogeneities, and tested in cardiac T1ρ quantification of healthy volunteers. The performance of the tan/tanh-SL was compared with the composite SL preparation pulses and the commonly used hyperbolic secant pulse for spin-lock (HS-SL). Feasible pulse shape parameters were obtained using Bloch simulation. Compared with HS-SL, the quantification error of tan/tanh-SL was reduced by 27.7% for Tp = 8 ms (mean ∆Q = 126.15 vs. 174.42) and 75.6% for Tp = 4 ms (mean ∆Q = 136.65 vs. 559.53). In the phantom study, tan/tanh-SL was less sensitive to B1 and B0 inhomogeneity compared with composite SL pulses and HS-SL. In cardiac T1ρ quantification, the T1ρ maps using tan/tanh-SL showed fewer banding artifacts than using composite SL pulses and HS-SL. The proposed tan/tanh-SL preparation module greatly improves the robustness to B0 and B1 field inhomogeneities and can be used in cardiac T1ρ quantification at 3 T.
Collapse
Affiliation(s)
- Yuxin Yang
- Paul C. Lauterbur Research Centre for Biomedical Imaging, Shenzhen Institutes of Advanced Technology, Chinese Academy of Sciences, Shenzhen, Guangdong, China
- Department of Biomedical Engineering, Chongqing University of Technology, Chongqing, China
| | - Che Wang
- Paul C. Lauterbur Research Centre for Biomedical Imaging, Shenzhen Institutes of Advanced Technology, Chinese Academy of Sciences, Shenzhen, Guangdong, China
- Department of Biomedical Engineering, Chongqing University of Technology, Chongqing, China
| | - Yuanyuan Liu
- Paul C. Lauterbur Research Centre for Biomedical Imaging, Shenzhen Institutes of Advanced Technology, Chinese Academy of Sciences, Shenzhen, Guangdong, China
| | - Zhongmin Chen
- Department of Biomedical Engineering, Chongqing University of Technology, Chongqing, China
| | - Xin Liu
- Paul C. Lauterbur Research Centre for Biomedical Imaging, Shenzhen Institutes of Advanced Technology, Chinese Academy of Sciences, Shenzhen, Guangdong, China
| | - Hairong Zheng
- Paul C. Lauterbur Research Centre for Biomedical Imaging, Shenzhen Institutes of Advanced Technology, Chinese Academy of Sciences, Shenzhen, Guangdong, China
| | - Dong Liang
- Paul C. Lauterbur Research Centre for Biomedical Imaging, Shenzhen Institutes of Advanced Technology, Chinese Academy of Sciences, Shenzhen, Guangdong, China
| | - Yanjie Zhu
- Paul C. Lauterbur Research Centre for Biomedical Imaging, Shenzhen Institutes of Advanced Technology, Chinese Academy of Sciences, Shenzhen, Guangdong, China
| |
Collapse
|
5
|
Distinct patterns of altered quantitative T1ρ and functional BOLD response associated with history of suicide attempts in bipolar disorder. Brain Imaging Behav 2022; 16:820-833. [PMID: 34601647 PMCID: PMC8975910 DOI: 10.1007/s11682-021-00552-2] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Accepted: 08/29/2021] [Indexed: 10/20/2022]
Abstract
Despite the high risk for suicide, relatively few studies have explored the relationship between suicide and brain imaging measures in bipolar disorder. In addition, fewer studies have explored the possibility that altered brain metabolism may be associated with suicide attempt. To begin to fill in these gaps, we evaluated functional (task based fMRI) and metabolic (quantitative T1ρ) differences associated with suicide attempt in participants with bipolar disorder. Thirty-nine participants with bipolar disorder underwent fMRI during a flashing checkerboard task and 27 also underwent quantitative T1ρ. The relationship between neuroimaging and history of suicide attempt was tested using multiple regression while adjusting for age, sex, and current mood state. Differences between two measures of suicide attempt (binary: yes/no and continuous: number of attempts) were quantified using the corrected Akaike Information Criterion. Participants who had attempted suicide had greater fMRI task-related activation in visual areas and the cerebellum. The number of suicide attempts was associated with a difference in BOLD response in the amygdala, prefrontal cortex, and cerebellum. Increased quantitative T1ρ was associated with number of suicide attempts in limbic, basal ganglia, and prefrontal cortex regions. This study is a secondary analysis with a modest sample size. Differences between measures of suicide history may be due to differences in statistical power. History of suicide was associated with limbic, prefrontal, and cerebellar alterations. Results comparing those with and without suicide attempts differed from results using number of suicide attempts, suggesting that these variables have different neurobiological underpinnings.
Collapse
|
6
|
Magnotta VA, Xu J, Fiedorowicz JG, Williams A, Shaffer J, Christensen G, Long JD, Taylor E, Sathyaputri L, Richards JG, Harmata G, Wemmie J. Metabolic abnormalities in the basal ganglia and cerebellum in bipolar disorder: A multi-modal MR study. J Affect Disord 2022; 301:390-399. [PMID: 35031333 PMCID: PMC8828710 DOI: 10.1016/j.jad.2022.01.052] [Citation(s) in RCA: 11] [Impact Index Per Article: 3.7] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 10/03/2021] [Revised: 12/28/2021] [Accepted: 01/10/2022] [Indexed: 12/21/2022]
Abstract
AIMS Bipolar type I disorder (BD) is characterized by severe mood swings and occurs in about 1% of the population. The mechanisms underlying the disorder remain unknown. Prior studies have suggested abnormalities in brain metabolism using 1H and 31P magnetic resonance spectroscopy (MRS). Supporting altered metabolism, in previous studies we found T1ρ relaxation times in the cerebellum were elevated in participants with BD. In addition, T1ρ relaxation times in the basal ganglia were lower in participants with BD experiencing depressed mood. Based on these findings, this study sought to probe brain metabolism with a focus of extending these assessments to the cerebellum. METHODS This study collected data from 64 participants with Bipolar type I disorder (BD) and 42 controls. Subjects were scanned at both 3T (anatomical, functional, and T1ρ imaging data) and 7T (31P and 1H spectroscopy). Regions of interest defined by the 1H MRS data were used to explore metabolic and functional changes in the cerebellar vermis and putamen. RESULTS Elevated concentrations of n-Acetyl-l-aspartate (NAA), glutamate, glutathione, taurine, and creatine were found in the cerebellar vermis along with decreased intra-cellular pH. Similar trends were observed in the right putamen for glutamate, creatine, and pH. We also observed a relationship between T1ρ relaxation times and mood in the putamen. We did not observe a significant effect of medications on these measures. LIMITATIONS The study was cross sectional in design and employed a naturalistic approach for assessing the impact of medications on the results. CONCLUSION This study supports prior findings of reduced pH in mitochondrial dysfunction in BD while also showing that these differences extend to the cerebellum.
Collapse
Affiliation(s)
- Vincent A Magnotta
- Department of Radiology, The University of Iowa, United States; Department of Psychiatry, The University of Iowa, United States; Department of Biomedical Engineering, The University of Iowa, United States.
| | - Jia Xu
- Department of Radiology, The University of Iowa, United States
| | | | | | - Joseph Shaffer
- Department of Radiology, The University of Iowa, United States; College of Biosciences, Kansas City University, United States
| | - Gary Christensen
- Department of Electrical and Computer Engineering, The University of Iowa, United States; Department of Radiation Oncology, The University of Iowa, United States
| | - Jeffrey D Long
- Department of Psychiatry, The University of Iowa, United States; Department of Biostatistics, The University of Iowa, United States
| | - Eric Taylor
- Department of Molecular Physiology and Biophysics, The University of Iowa, United States
| | | | | | - Gail Harmata
- Department of Psychiatry, The University of Iowa, United States
| | - John Wemmie
- Department of Psychiatry, The University of Iowa, United States; Department of Molecular Physiology and Biophysics, The University of Iowa, United States; Department of Neurosurgery, The University of Iowa, United States
| |
Collapse
|
7
|
Saito S. [5. Advanced Imaging Technology-T1rho-CEST Imaging]. Nihon Hoshasen Gijutsu Gakkai Zasshi 2022; 78:95-100. [PMID: 35046227 DOI: 10.6009/jjrt.780111] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/11/2022]
Affiliation(s)
- Shigeyoshi Saito
- Laboratory of Advanced Imaging Technology, Department of Medical Physics and Engineering, Division of Health Sciences, Osaka University Graduate School of Medicine.,Department of Advanced Medical Technology, National Cardiovascular and Cerebral Research Center
| |
Collapse
|
8
|
Sodoma MJ, Cole RC, Sloan TJ, Hamilton CM, Kent JD, Magnotta VA, Voss MW. Hippocampal acidity and volume are differentially associated with spatial navigation in older adults. Neuroimage 2021; 245:118682. [PMID: 34728245 PMCID: PMC8867536 DOI: 10.1016/j.neuroimage.2021.118682] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/15/2021] [Revised: 09/14/2021] [Accepted: 10/25/2021] [Indexed: 11/17/2022] Open
Abstract
The hippocampus is negatively affected by aging and is critical for spatial navigation. While there is evidence that wayfinding navigation tasks are especially sensitive to preclinical hippocampal deterioration, these studies have primarily used volumetric hippocampal imaging without considering microstructural properties or anatomical variation within the hippocampus. T1ρ is an MRI measure sensitive to regional pH, with longer relaxation rates reflecting acidosis as a marker of metabolic dysfunction and neuropathological burden. For the first time, we investigate how measures of wayfinding including landmark location learning and delayed memory in cognitively normal older adults (N = 84) relate to both hippocampal volume and T1ρ in the anterior and posterior hippocampus. Regression analyses revealed hippocampal volume was bilaterally related to learning, while right lateralized T1ρ was related to delayed landmark location memory and bilateral T1ρ was related to the delayed use of a cognitive map. Overall, results suggest hippocampal volume and T1ρ relaxation rate tap into distinct mechanisms involved in preclinical cognitive decline as assessed by wayfinding navigation, and laterality influenced these relationships more than the anterior-posterior longitudinal axis of the hippocampus.
Collapse
Affiliation(s)
- Matthew J Sodoma
- Department of Psychological and Brain Sciences, University of Iowa, Iowa City, IA 52242, USA.
| | - Rachel C Cole
- Interdisciplinary Graduate Program in Neuroscience, University of Iowa, Iowa City, IA 52242, USA; Department of Neurology, University of Iowa, Iowa City, IA, 52242, USA
| | - Taylor J Sloan
- Department of Psychological and Brain Sciences, University of Iowa, Iowa City, IA 52242, USA
| | - Chase M Hamilton
- Department of Psychological and Brain Sciences, University of Iowa, Iowa City, IA 52242, USA
| | - James D Kent
- Interdisciplinary Graduate Program in Neuroscience, University of Iowa, Iowa City, IA 52242, USA; Department of Psychology, University of Texas at Austin, Austin, TX, 78712 USA
| | - Vincent A Magnotta
- Iowa Neuroscience Institute, University of Iowa, Iowa City, IA 52242, USA; Department of Radiology, University of Iowa, Iowa City, IA 52242, UCA; Department of Biomedical Engineering, University of Iowa, Iowa City, IA 52242, USA; Department of Psychiatry, University of Iowa, Iowa City, IA 52242, USA; Pappajohn Biomedical Institute, University of Iowa, Iowa City, IA 52242, USA
| | - Michelle W Voss
- Department of Psychological and Brain Sciences, University of Iowa, Iowa City, IA 52242, USA; Interdisciplinary Graduate Program in Neuroscience, University of Iowa, Iowa City, IA 52242, USA; Iowa Neuroscience Institute, University of Iowa, Iowa City, IA 52242, USA
| |
Collapse
|
9
|
Ponto LLB, Magnotta VA, Menda Y, Moser DJ, Oleson JJ, Harlynn EL, DeVries SD, Wemmie JA, Schultz SK. Comparison of T 1Rho MRI, Glucose Metabolism, and Amyloid Burden Across the Cognitive Spectrum: A Pilot Study. J Neuropsychiatry Clin Neurosci 2020; 32:352-361. [PMID: 32283991 PMCID: PMC8717916 DOI: 10.1176/appi.neuropsych.19100221] [Citation(s) in RCA: 4] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 11/30/2022]
Abstract
OBJECTIVE The pathological cascades associated with the development of Alzheimer's disease (AD) have a common element: acidosis. T1rho MRI is a pH-sensitive measure, with higher values associated with greater neuropathological burden. The authors investigated the relationship between T1rho imaging and AD-associated pathologies as determined by available diagnostic imaging techniques. METHODS Twenty-seven participants (men, N=13, women, N=14; ages 55-90) across the cognitive spectrum (healthy control subjects [HCs] with normal cognition, N=17; participants with mild cognitive impairment [MCI], N=7; participants with mild AD, N=3) underwent neuropsychological testing, MRI (T1-weighted and T1rho [spin-lattice relaxation time in the rotating frame]), and positron emission tomography imaging ([11C]Pittsburg compound B for amyloid burden [N=26] and [18F]fluorodeoxyglucose for cerebral glucose metabolism [N=12]). The relationships between global T1rho values and neuropsychological, demographic, and imaging measures were explored. RESULTS Global mean and median T1rho were positively associated with age. After controlling for age, higher global T1rho was associated with poorer cognitive function, poorer memory function (immediate and delayed memory scores), higher amyloid burden, and more abnormal cerebral glucose metabolism. Regional T1rho values, when controlling for age, significantly differed between HCs and participants with MCI or AD in select frontal, cingulate, and parietal regions. CONCLUSIONS Higher T1rho values were associated with greater cognitive impairment and pathological burden. T1rho, a biomarker that varies according to a feature common to each cascade rather than one that is unique to a particular pathology, has the potential to serve as a metric of neuropathology, theoretically providing a measure for assessing pathological status and for monitoring the neurodegeneration trajectory.
Collapse
Affiliation(s)
| | - Vincent A. Magnotta
- Department of Radiology, Carver College of Medicine, University of Iowa,Department of Psychiatry, Carver College of Medicine, University of Iowa
| | - Yusuf Menda
- Department of Radiology, Carver College of Medicine, University of Iowa
| | - David J. Moser
- Department of Psychiatry, Carver College of Medicine, University of Iowa
| | - Jacob J. Oleson
- Department of Biostatistics, College of Public Health, University of Iowa
| | - Emily L. Harlynn
- Department of Radiology, Carver College of Medicine, University of Iowa
| | - Sean D. DeVries
- Department of Biostatistics, College of Public Health, University of Iowa
| | - John A. Wemmie
- Department of Psychiatry, Carver College of Medicine, University of Iowa
| | - Susan K. Schultz
- Department of Psychiatry, Carver College of Medicine, University of Iowa
| |
Collapse
|
10
|
Shaffer JJ, Mani M, Schmitz SL, Xu J, Owusu N, Wu D, Magnotta VA, Wemmie JA. Proton Exchange Magnetic Resonance Imaging: Current and Future Applications in Psychiatric Research. Front Psychiatry 2020; 11:532606. [PMID: 33192650 PMCID: PMC7542226 DOI: 10.3389/fpsyt.2020.532606] [Citation(s) in RCA: 4] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 02/04/2020] [Accepted: 09/02/2020] [Indexed: 12/20/2022] Open
Abstract
Proton exchange provides a powerful contrast mechanism for magnetic resonance imaging (MRI). MRI techniques sensitive to proton exchange provide new opportunities to map, with high spatial and temporal resolution, compounds important for brain metabolism and function. Two such techniques, chemical exchange saturation transfer (CEST) and T1 relaxation in the rotating frame (T1ρ), are emerging as promising tools in the study of neurological and psychiatric illnesses to study brain metabolism. This review describes proton exchange for non-experts, highlights the current status of proton-exchange MRI, and presents advantages and drawbacks of these techniques compared to more traditional methods of imaging brain metabolism, including positron emission tomography (PET) and MR spectroscopy (MRS). Finally, this review highlights new frontiers for the use of CEST and T1ρ in brain research.
Collapse
Affiliation(s)
- Joseph J Shaffer
- Department of Radiology, University of Iowa, Iowa City, IA, United States
| | - Merry Mani
- Department of Radiology, University of Iowa, Iowa City, IA, United States
| | - Samantha L Schmitz
- Department of Psychiatry, University of Iowa, Iowa City, IA, United States
| | - Jia Xu
- Department of Radiology, University of Iowa, Iowa City, IA, United States
| | - Nana Owusu
- Department of Radiology, University of Iowa, Iowa City, IA, United States.,Pappajohn Biomedical Institute, University of Iowa, Iowa City, IA, United States.,Department of Biomedical Engineering, University of Iowa, Iowa City, IA, United States
| | - Dee Wu
- Department of Radiology, University of Oklahoma Health Sciences Center, Oklahoma City, OK, United States
| | - Vincent A Magnotta
- Department of Radiology, University of Iowa, Iowa City, IA, United States.,Department of Psychiatry, University of Iowa, Iowa City, IA, United States.,Department of Biomedical Engineering, University of Iowa, Iowa City, IA, United States
| | - John A Wemmie
- Department of Psychiatry, University of Iowa, Iowa City, IA, United States.,Pappajohn Biomedical Institute, University of Iowa, Iowa City, IA, United States.,Department of Veterans Affairs Medical Center, Iowa City, IA, United States.,Department of Molecular Physiology and Biophysics, University of Iowa, Iowa City, IA, United States.,Department of Neurosurgery, University of Iowa, Iowa City, IA, United States
| |
Collapse
|