1
|
Kraff O, May MW. Multi-center QA of ultrahigh-field systems. MAGMA (NEW YORK, N.Y.) 2025:10.1007/s10334-025-01232-8. [PMID: 40126781 DOI: 10.1007/s10334-025-01232-8] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Subscribe] [Scholar Register] [Received: 10/02/2024] [Revised: 01/21/2025] [Accepted: 01/30/2025] [Indexed: 03/26/2025]
Abstract
Over the past two decades, ultra-high field (UHF) magnetic resonance imaging (MRI) has evolved from pure investigational devices to now systems with CE and FDA clearance for clinical use. UHF MRI offers enhanced diagnostic value, especially in brain and musculoskeletal imaging, aiding in the differential diagnosis of conditions like multiple sclerosis and epilepsy. However, to fully harness the potential of UHF, multi-center studies and quality assurance (QA) protocols are critical for ensuring reproducibility across different systems and sites. This becomes even more vital as the UHF community comprises three generations of magnet design, and many UHF sites are currently upgrading to the latest system architecture. Hence, this review presents multi-center QA measurements that have been performed at UHF, in particular from larger consortia through their "travelling heads" studies. Despite the technical variability between different vendors and system generations, these studies have shown a high level of reproducibility in structural and quantitative imaging. Furthermore, the review highlights the ongoing challenges in QA, such as transmitter performance drift and the need for a standard reliable multi-tissue phantom for RF coil calibration, which are crucial for advancing UHF MRI in both clinical and research applications.
Collapse
Affiliation(s)
- Oliver Kraff
- Erwin L. Hahn Institute for MR Imaging, University of Duisburg-Essen, Kokereiallee 7, 45141, Essen, Germany.
| | - Markus W May
- Erwin L. Hahn Institute for MR Imaging, University of Duisburg-Essen, Kokereiallee 7, 45141, Essen, Germany
- High-Field and Hybrid MR Imaging, University Hospital Essen, Essen, Germany
| |
Collapse
|
2
|
Jung S, Hoffmann M, Winkler D, Güresir E, Kropla F, Scholz S, Grunert R. Influence of the orientation of constructed blood vessels during the 3D printing on the measurement of the pseudo-oxygen saturation of an artificial blood substitute using conventional oxygen sensors: a test series. 3D Print Med 2024; 10:40. [PMID: 39592528 PMCID: PMC11600587 DOI: 10.1186/s41205-024-00246-7] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/05/2023] [Accepted: 11/15/2024] [Indexed: 11/28/2024] Open
Abstract
BACKGROUND The development of phantoms to reduce animal testing or to validate new instruments or operation techniques is of increasing importance. For this reason, a blood circulation phantom was developed to test a newly designed retractor system with an integrated oxygen sensor. This phantom was used to evaluate the impact of the 3D printed blood vessel on the measurement of the oxygen saturation. METHODS A solution of nickel sulfate and copper sulfate was prepared as a substitute for real blood. The absorption spectra of these solutions were recorded and compared with those of blood. Subsequently, the oxygen sensor used was calibrated to the blood substitute. Additionally, blood vessels with a simplified geometry were designed and manufactured using inverted vat polymerization and an elastic material (Formlabs Elastic 50 A). To determine the orientation during the printing process, various vessels were printed. Measurements to assess the effects of disturbance (rotation of the vessels during measurements) on the sensor readouts were prepared. RESULTS The impact of disturbances was verified through the rotation of the 3D printed vessels. It was demonstrated that a direct measurement on the disturbances led to outliers and higher values. An optimal orientation was determined to be a lateral placement (90° or 270°) of the sensor. Regarding the orientation of the vessels within the printing space, an orientation of 45° yielded the best results, as the individual layers had the least impact on the light emitted and received by the oxygen sensor. CONCLUSION The achieved results demonstrate the influence of the orientation of the vessel during 3D printing as well as the influence of the position of the vessel during the measurement using a conventional oxygen sensor.
Collapse
Affiliation(s)
- Svenja Jung
- Department of Neurosurgery, University of Leipzig Medical Center, Liebigstr.20, 04103, Leipzig, Germany.
| | - Martin Hoffmann
- Department of Neurosurgery, University of Leipzig Medical Center, Liebigstr.20, 04103, Leipzig, Germany
| | - Dirk Winkler
- Department of Neurosurgery, University of Leipzig Medical Center, Liebigstr.20, 04103, Leipzig, Germany
| | - Erdem Güresir
- Department of Neurosurgery, University of Leipzig Medical Center, Liebigstr.20, 04103, Leipzig, Germany
| | - Fabian Kropla
- Department of Neurosurgery, University of Leipzig Medical Center, Liebigstr.20, 04103, Leipzig, Germany
| | - Sebastian Scholz
- Fraunhofer-Institute for Machine Tools and Forming Technology, 02763, Zittau, Germany
| | - Ronny Grunert
- Department of Neurosurgery, University of Leipzig Medical Center, Liebigstr.20, 04103, Leipzig, Germany
- Fraunhofer-Institute for Machine Tools and Forming Technology, 02763, Zittau, Germany
| |
Collapse
|
3
|
Pirozzi MA, Gaudieri V, Prinster A, Magliulo M, Cuocolo A, Brunetti A, Alfano B, Quarantelli M. StepBrain: A 3-Dimensionally Printed Multicompartmental Anthropomorphic Brain Phantom to Simulate PET Activity Distributions. J Nucl Med 2024; 65:1489-1492. [PMID: 39025647 PMCID: PMC11372253 DOI: 10.2967/jnumed.123.267277] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/19/2023] [Accepted: 04/08/2024] [Indexed: 07/20/2024] Open
Abstract
An innovative multicompartmental anatomic brain phantom (StepBrain) is described to simulate the in vivo tracer uptake of gray matter, white matter, and striatum, overcoming the limitations of currently available phantoms. Methods: StepBrain was created by exploiting the potential of fused deposition modeling 3-dimensional printing to replicate the real anatomy of the brain compartments, as modeled through ad hoc processing of healthy-volunteer MR images. Results: A realistic simulation of 18F-FDG PET brain studies, using target activity to obtain the real concentration ratios, was obtained, and the results of postprocessing with partial-volume effect correction tools developed for human PET studies confirmed the accuracy of these methods in recovering the target activity concentrations. Conclusion: StepBrain compartments (gray matter, white matter, and striatum) can be simultaneously filled, achieving different concentration ratios and allowing the simulation of different (e.g., amyloid, tau, or 6-fluoro-l-dopa) tracer distributions, with a potentially valuable role for multicenter PET harmonization studies.
Collapse
Affiliation(s)
- Maria Agnese Pirozzi
- Department of Advanced Medical and Surgical Sciences, University of Campania "Luigi Vanvitelli," Naples, Italy;
| | - Valeria Gaudieri
- Department of Advanced Biomedical Sciences, University of Naples "Federico II," Naples, Italy
| | - Anna Prinster
- Institute of Biostructures and Bioimaging, National Research Council, Naples, Italy; and
| | - Mario Magliulo
- Institute of Biostructures and Bioimaging, National Research Council, Naples, Italy; and
| | - Alberto Cuocolo
- Department of Advanced Biomedical Sciences, University of Naples "Federico II," Naples, Italy
| | - Arturo Brunetti
- Department of Advanced Biomedical Sciences, University of Naples "Federico II," Naples, Italy
| | | | - Mario Quarantelli
- Institute of Biostructures and Bioimaging, National Research Council, Naples, Italy; and
| |
Collapse
|
4
|
Delebarre T, Gras V, Mauconduit F, Vignaud A, Boulant N, Ciobanu L. Efficient optimization of chemical exchange saturation transfer MRI at 7 T using universal pulses and virtual observation points. Magn Reson Med 2023; 90:51-63. [PMID: 36779346 DOI: 10.1002/mrm.29617] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/12/2022] [Revised: 01/17/2023] [Accepted: 01/27/2023] [Indexed: 02/14/2023]
Abstract
PURPOSE To optimize the homogeneity of the presaturation module in a Chemical Exchange Saturation Transfer (CEST) acquisition at 7 T using parallel transmission (pTx). THEORY AND METHODS An optimized pTx-CEST presaturation scheme based on precomputed universal pulses was designed. The optimization was performed by minimizing the L2-norm between the effective B 1 , RMS + $$ {B}_{1,\mathrm{RMS}}^{+} $$ and a given target while imposing energy constraints under virtual observation points (VOPs) supervision. The proposed method was evaluated through simulations and experimentally, both in vitro, on a realistic human head phantom, and in vivo, on healthy volunteers. The results were compared with circular polarization (CP) presaturation and other pTx approaches previously proposed. All experiments were conducted on a 7 T MRI scanner using a commercial 8Tx/32Rx head coil. RESULTS The simulations show that the proposed pTx strategy boosted with VOPs is superior to the CP mode and existent pTx approaches. While the best results are obtained with subject specific pulses, the gain provided by the use of VOPs renders the universal pulses superior to tailored pulses optimized under vendor provided Specific Absorption Rate (SAR) management. In the phantom, the glucose MTR asym $$ {\mathrm{MTR}}_{\mathrm{asym}} $$ map was significantly more homogeneous than with CP (root mean square error [RMSE] 17% vs. 30%). The efficiency of the method for in vivo hydroxyl, glutamate and rNOE weighted CEST acquisitions was also demonstrated. CONCLUSION The use of a pTx presaturation scheme based on universal pulses optimized under VOP SAR management is significantly benefiting CEST imaging at high magnetic field.
Collapse
Affiliation(s)
- Thaddée Delebarre
- NeuroSpin, UMR CEA/CNRS 9027, Paris-Saclay University, Gif-sur-Yvette, France
| | - Vincent Gras
- NeuroSpin, UMR CEA/CNRS 9027, Paris-Saclay University, Gif-sur-Yvette, France
| | - Franck Mauconduit
- NeuroSpin, UMR CEA/CNRS 9027, Paris-Saclay University, Gif-sur-Yvette, France
| | - Alexandre Vignaud
- NeuroSpin, UMR CEA/CNRS 9027, Paris-Saclay University, Gif-sur-Yvette, France
| | - Nicolas Boulant
- NeuroSpin, UMR CEA/CNRS 9027, Paris-Saclay University, Gif-sur-Yvette, France
| | - Luisa Ciobanu
- NeuroSpin, UMR CEA/CNRS 9027, Paris-Saclay University, Gif-sur-Yvette, France
| |
Collapse
|
5
|
Seginer A, Keith GA, Porter DA, Schmidt R. Artifact suppression in readout-segmented consistent K-t space EPSI (RS-COKE) for fast 1 H spectroscopic imaging at 7 T. Magn Reson Med 2022; 88:2339-2357. [PMID: 35975965 PMCID: PMC9804880 DOI: 10.1002/mrm.29373] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/16/2022] [Revised: 06/08/2022] [Accepted: 06/09/2022] [Indexed: 01/09/2023]
Abstract
PURPOSE Fast proton (1 H) MRSI is an important diagnostic tool for clinical investigations, providing metabolic and spatial information. MRSI at 7 T benefits from increased SNR and improved separation of peaks but requires larger spectral widths. RS-COKE (Readout-Segmented Consistent K-t space Epsi) is an echo planar spectroscopic imaging (Epsi) variant capable to support the spectral width required for human brain metabolites spectra at 7 T. However, mismatches between readout segments lead to artifacts, particularly when subcutaneous lipid signals are not suppressed. In this study, these mismatches and their effects are analyzed and reduced. METHODS The following corrections to the data were performed: i) frequency-dependent phase corrections; ii) k-space trajectory corrections, derived from short reference scans; and iii) smoothing of data at segment transitions to mitigate the effect of residual mismatches. The improvement was evaluated by performing single-slice RS-COKE on a head-shaped phantom with a "lipid" layer and healthy subjects, using varying resolutions and durations ranging from 4.1 × 4.7 × 15 mm3 in 5:46 min to 3.1 × 3.3 × 15 mm3 in 13:07 min. RESULTS Artifacts arising from the readout-segmented acquisition were substantially reduced, thus providing high-quality spectroscopic imaging in phantom and human scans. LCModel fitting of the human data resulted in a relative Cramer-Rao lower bounds within 6% for NAA, Cr, and Cho images in the majority of the voxels. CONCLUSION Using the new reference scans and reconstruction steps, RS-COKE was able to deliver fast 1 H MRSI at 7 T, overcoming the spectral width limitation of standard EPSI at this field strength.
Collapse
Affiliation(s)
| | - Graeme A. Keith
- Imaging Centre of ExcellenceUniversity of GlasgowGlasgowUnited Kingdom
| | - David A. Porter
- Imaging Centre of ExcellenceUniversity of GlasgowGlasgowUnited Kingdom
| | - Rita Schmidt
- Department of Brain SciencesWeizmann Institute of ScienceRehovotIsrael,The Azrieli National Institute for Human Brain Imaging and ResearchWeizmann Institute of ScienceRehovotIsrael
| |
Collapse
|
6
|
Seginer A, Schmidt R. Phase-based fast 3D high-resolution quantitative T 2 MRI in 7 T human brain imaging. Sci Rep 2022; 12:14088. [PMID: 35982143 PMCID: PMC9388657 DOI: 10.1038/s41598-022-17607-z] [Citation(s) in RCA: 3] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/24/2022] [Accepted: 07/28/2022] [Indexed: 12/04/2022] Open
Abstract
Magnetic resonance imaging (MRI) is a powerful and versatile technique that offers a range of physiological, diagnostic, structural, and functional measurements. One of the most widely used basic contrasts in MRI diagnostics is transverse relaxation time (T2)-weighted imaging, but it provides only qualitative information. Realizing quantitative high-resolution T2 mapping is imperative for the development of personalized medicine, as it can enable the characterization of diseases progression. While ultra-high-field (≥ 7 T) MRI offers the means to gain new insights by increasing the spatial resolution, implementing fast quantitative T2 mapping cannot be achieved without overcoming the increased power deposition and radio frequency (RF) field inhomogeneity at ultra-high-fields. A recent study has demonstrated a new phase-based T2 mapping approach based on fast steady-state acquisitions. We extend this new approach to ultra-high field MRI, achieving quantitative high-resolution 3D T2 mapping at 7 T while addressing RF field inhomogeneity and utilizing low flip angle pulses; overcoming two main ultra-high field challenges. The method is based on controlling the coherent transverse magnetization in a steady-state gradient echo acquisition; achieved by utilizing low flip angles, a specific phase increment for the RF pulses, and short repetition times. This approach simultaneously extracts both T2 and RF field maps from the phase of the signal. Prior to in vivo experiments, the method was assessed using a 3D head-shaped phantom that was designed to model the RF field distribution in the brain. Our approach delivers fast 3D whole brain images with submillimeter resolution without requiring special hardware, such as multi-channel transmit coil, thus promoting high usability of the ultra-high field MRI in clinical practice.
Collapse
Affiliation(s)
| | - Rita Schmidt
- Department of Brain Sciences, Weizmann Institute of Science, Rehovot, Israel. .,The Azrieli National Institute for Human Brain Imaging and Research, Weizmann Institute of Science, Rehovot, Israel.
| |
Collapse
|
7
|
Bouattour Y, Sautou V, Hmede R, El Ouadhi Y, Gouot D, Chennell P, Lapusta Y, Chapelle F, Lemaire JJ. A Minireview on Brain Models Simulating Geometrical, Physical, and Biochemical Properties of the Human Brain. Front Bioeng Biotechnol 2022; 10:818201. [PMID: 35419353 PMCID: PMC8996142 DOI: 10.3389/fbioe.2022.818201] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/19/2021] [Accepted: 03/08/2022] [Indexed: 11/13/2022] Open
Abstract
There is a growing body of evidences that brain surrogates will be of great interest for researchers and physicians in the medical field. They are currently mainly used for education and training purposes or to verify the appropriate functionality of medical devices. Depending on the purpose, a variety of materials have been used with specific and accurate mechanical and biophysical properties, More recently they have been used to assess the biocompatibility of implantable devices, but they are still not validated to study the migration of leaching components from devices. This minireview shows the large diversity of approaches and uses of brain phantoms, which converge punctually. All these phantoms are complementary to numeric models, which benefit, reciprocally, of their respective advances. It also suggests avenues of research for the analysis of leaching components from implantable devices.
Collapse
Affiliation(s)
- Yassine Bouattour
- Université Clermont Auvergne, CHU Clermont Ferrand, Clermont Auvergne INP, CNRS, ICCF, F-63000, Clermont-Ferrand, France
- *Correspondence: Yassine Bouattour, ; Jean-Jacques Lemaire,
| | - Valérie Sautou
- Université Clermont Auvergne, CHU Clermont Ferrand, Clermont Auvergne INP, CNRS, ICCF, F-63000, Clermont-Ferrand, France
| | - Rodayna Hmede
- Universite Clermont Auvergne, CNRS, Clermont Auvergne INP, Institut Pascal, F-63000, Clermont-Ferrand, France
| | - Youssef El Ouadhi
- Universite Clermont Auvergne, CNRS, Clermont Auvergne INP, Institut Pascal, F-63000, Clermont-Ferrand, France
- Service de Neurochirurgie, CHU Clermont Ferrand, F-63000, Clermont-Ferrand, France
| | - Dimitri Gouot
- Universite Clermont Auvergne, CNRS, Clermont Auvergne INP, Institut Pascal, F-63000, Clermont-Ferrand, France
| | - Philip Chennell
- Université Clermont Auvergne, CHU Clermont Ferrand, Clermont Auvergne INP, CNRS, ICCF, F-63000, Clermont-Ferrand, France
| | - Yuri Lapusta
- Universite Clermont Auvergne, CNRS, Clermont Auvergne INP, Institut Pascal, F-63000, Clermont-Ferrand, France
| | - Frédéric Chapelle
- Universite Clermont Auvergne, CNRS, Clermont Auvergne INP, Institut Pascal, F-63000, Clermont-Ferrand, France
| | - Jean-Jacques Lemaire
- Universite Clermont Auvergne, CNRS, Clermont Auvergne INP, Institut Pascal, F-63000, Clermont-Ferrand, France
- Service de Neurochirurgie, CHU Clermont Ferrand, F-63000, Clermont-Ferrand, France
- *Correspondence: Yassine Bouattour, ; Jean-Jacques Lemaire,
| |
Collapse
|
8
|
Reducing SAR in 7T brain fMRI by circumventing fat suppression while removing the lipid signal through a parallel acquisition approach. Sci Rep 2021; 11:15371. [PMID: 34321529 PMCID: PMC8319205 DOI: 10.1038/s41598-021-94692-6] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/30/2020] [Accepted: 07/09/2021] [Indexed: 12/14/2022] Open
Abstract
Ultra-high-field functional magnetic resonance imaging (fMRI) offers a way to new insights while increasing the spatial and temporal resolution. However, a crucial concern in 7T human MRI is the increase in power deposition, supervised through the specific absorption rate (SAR). The SAR limitation can restrict the brain coverage or the minimal repetition time of fMRI experiments. In the majority of today’s studies fMRI relies on the well-known gradient-echo echo-planar imaging (GRE-EPI) sequence, which offers ultrafast acquisition. Commonly, the GRE-EPI sequence comprises two pulses: fat suppression and excitation. This work provides the means for a significant reduction in the SAR by circumventing the fat-suppression pulse. Without this fat-suppression, however, lipid signal can result in artifacts due to the chemical shift between the lipid and water signals. Our approach exploits a reconstruction similar to the simultaneous-multi-slice method to separate the lipid and water images, thus avoiding undesired lipid artifacts in brain images. The lipid-water separation is based on the known spatial shift of the lipid signal, which can be detected by the multi-channel coils sensitivity profiles. Our study shows robust human imaging, offering greater flexibility to reduce the SAR, shorten the repetition time or increase the volume coverage with substantial benefit for brain functional studies.
Collapse
|