1
|
Lindhardt RB, Kronborg JR, Wanscher M, Andersen LW, Gjedsted J, Ravn HB. Evaluation of Thromboelastography 6s prognostication of fibrinogen supplementation in pediatric cardiac surgery. Acta Anaesthesiol Scand 2022; 66:1166-1173. [PMID: 36054262 PMCID: PMC9826011 DOI: 10.1111/aas.14144] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/22/2022] [Revised: 07/19/2022] [Accepted: 08/15/2022] [Indexed: 01/11/2023]
Abstract
BACKGROUND Implementation of point-of-care tests is recommended to provide tailored substitution during cardiac surgery. The measurement and substitution of fibrinogen have gained particular interest since it is the first coagulation factor to become depleted during cardiac surgery. However, the prognostic ability of thromboelastography (TEG) 6s has not been evaluated in pediatric patients. The aim of the present study was to describe patient characteristics of infants receiving fibrinogen substitution during cardiac surgery and evaluate the prognostic ability of TEG6s after weaning off cardiopulmonary bypass (CPB). METHODS Infants undergoing congenital cardiac surgery with CPB were retrospectively included (n = 279) between January 2017 to July 2019. Patient and perioperative data were collected on the day of surgery until 6:00 AM the next morning. Hemostatic capacity was assessed with TEG6s. The efficacy of TEG-functional fibrinogen-maximal amplitude (TEG-FF-MA) measurements for the prediction of intraoperative bleeding, and thereby cryoprecipitate need, was evaluated by a sensitivity and specificity analysis. RESULTS Among 174 children with TEG-FF-MA data, 147 (84%) received cryoprecipitate intraoperatively. Cryoprecipitate administration was associated with younger age 66 (10-132) versus 98 (45-204) days (p = .044), higher RACHS-1 classification, and intraoperative bleeding 21 (11-47) versus 5 (3-13) ml/kg (p < .001, mean difference 29 ml/kg [CI: 8-50]). Median TEG-FF-MA values were lower in transfused children 7.6 (5.3-11.0) versus 10.5 (7.3-13.4) mm (p = .004, mean difference - 2.4 mm [CI: -4.1 to - 0.73]). The volume of cryoprecipitate was associated with bypass time, TEG-FF-MA values, and in particular intraoperative bleeding volumes. A TEG-FF-MA threshold of 10.0 mm, resulted in sensitivity: 74%, specificity: 56%, positive predictive value: 80%, and a negative predictive value of 47% for the prediction of intraoperative bleeding (>10 ml/kg) and consequently a need of cryoprecipitate transfusion. CONCLUSION Fibrinogen substitution in infants was associated with younger age and higher RACHS-1 category. The prognostic value of TEG6s was evaluated, and cryoprecipitate transfusion was related to TEG-FF-MA values, but also CPB-time, surgical complexity, and in particular excessive intraoperative bleeding. A clear-cut threshold for TEG-FF-MA is difficult to establish in infants undertaken congenital heart surgery.
Collapse
Affiliation(s)
- Rasmus Bo Lindhardt
- Department of Cardiothoracic Anesthesiology, RigshospitaletCopenhagen University HospitalCopenhagenDenmark
| | - Jonas Rønne Kronborg
- Department of Cardiothoracic Anesthesiology, RigshospitaletCopenhagen University HospitalCopenhagenDenmark
| | - Michael Wanscher
- Department of Cardiothoracic Anesthesiology, RigshospitaletCopenhagen University HospitalCopenhagenDenmark
| | - Lars Willy Andersen
- Department of Cardiothoracic Anesthesiology, RigshospitaletCopenhagen University HospitalCopenhagenDenmark
| | - Jakob Gjedsted
- Department of Cardiothoracic Anesthesiology, RigshospitaletCopenhagen University HospitalCopenhagenDenmark,Institute of Clinical Medicine, Health FacultyUniversity of CopenhagenCopenhagenDenmark
| | - Hanne Berg Ravn
- Department of Cardiothoracic Anesthesiology, RigshospitaletCopenhagen University HospitalCopenhagenDenmark,Institute of Clinical Medicine, Health FacultyUniversity of CopenhagenCopenhagenDenmark,Institute of Clinical MedicineUniversity of Southern DenmarkOdenseDenmark,Department of Anesthesiology and Intensive CareOdense University HospitalOdenseDenmark
| |
Collapse
|
2
|
Khandelwal A, Minuk L, Liu Y, Arnold DM, Heddle NM, Barty R, Hsia C, Solh Z, Shehata N, Thompson T, Tinmouth A, Perelman I, Skeate R, Kron AT, Callum J. Plasma transfusion practices: A multicentre electronic audit. Vox Sang 2022; 117:1211-1219. [PMID: 36102150 DOI: 10.1111/vox.13355] [Citation(s) in RCA: 5] [Impact Index Per Article: 1.7] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/29/2022] [Revised: 08/02/2022] [Accepted: 08/16/2022] [Indexed: 11/28/2022]
Abstract
BACKGROUND AND OBJECTIVES Plasma is often transfused to patients with bleeding or requiring invasive procedures and with abnormal tests of coagulation. Chart audits find half of plasma transfusions unnecessary, resulting in avoidable complications and costs. This multicentre electronic audit was conducted to determine the proportion of plasma transfused without an indication and/or at a sub-therapeutic dose. METHODS Data were extracted on adult inpatients in 2017 at five academic sites from the hospital electronic chart, laboratory information systems and the Canadian Institute for Health Information Discharge Abstract Database. Electronic criteria for plasma transfusion outside recommended indications were: (1) international normalized ratio (INR) < 1.5 with no to moderate bleeding; (2) INR ≥ 1.5, with no to mild bleeding and no planned procedures; and (3) no INR before or after plasma infusion. Sub-therapeutic dose was defined as ≤2 units transfused. RESULTS In 1 year, 2590 patients received 6088 plasma transfusions encompassing 11,490 units of plasma occurred at the five sites. 77.7% of events were either outside indications or under-dosed. Of these, 34.8% of plasma orders had no indication identified, and 62% of these occurred in non-bleeding patients and no planned procedure with an isolated elevated INR. 70.7% of transfusions were under-dosed. Most plasma transfusions occurred in the intensive care unit or the operating room. Inter-hospital variability in peri-transfusion testing and dosing was observed. CONCLUSION The majority of plasma transfusions are sub-optimal. Local hospital culture may be an important driver. Electronic audits, with definitions employed in this study, may be a practical alternative to costly chart audits.
Collapse
Affiliation(s)
- Aditi Khandelwal
- Canadian Blood Services, Toronto, Ontario, Canada.,The University of Toronto Quality in Utilization, Education and Safety in Transfusion (QUEST) Research Program, Toronto, Ontario, Canada
| | - Leigh Minuk
- Department of Internal Medicine, University of Toronto, Toronto, Ontario, Canada
| | - Yang Liu
- McMaster Centre for Transfusion Research (MCTR), McMaster University, Hamilton, Ontario, Canada
| | - Donald M Arnold
- McMaster Centre for Transfusion Research (MCTR), McMaster University, Hamilton, Ontario, Canada.,Division of Hematology and Thromboembolism, Department of Medicine, McMaster University, Hamilton, Ontario, Canada
| | - Nancy M Heddle
- McMaster Centre for Transfusion Research (MCTR), McMaster University, Hamilton, Ontario, Canada.,Department of Pathology and Molecular Medicine, McMaster University, Hamilton, Ontario, Canada
| | - Rebecca Barty
- McMaster Centre for Transfusion Research (MCTR), McMaster University, Hamilton, Ontario, Canada.,Ontario Regional Blood Coordinating Network (ORBCoN), Toronto, Ontario, Canada
| | - Cyrus Hsia
- Department of Medicine, Western University, London, Ontario, Canada.,Department of Pathology and Laboratory Medicine, Western University, London, Ontario, Canada.,Transfusion Medicine Laboratories, London Health Sciences Centre, London, Ontario, Canada
| | - Ziad Solh
- Department of Medicine, Western University, London, Ontario, Canada.,Department of Pathology and Laboratory Medicine, Western University, London, Ontario, Canada.,Transfusion Medicine Laboratories, London Health Sciences Centre, London, Ontario, Canada
| | - Nadine Shehata
- The University of Toronto Quality in Utilization, Education and Safety in Transfusion (QUEST) Research Program, Toronto, Ontario, Canada.,Department of Laboratory Medicine and Pathology, Mount Sinai Hospital, University of Toronto, Toronto, Ontario, Canada
| | - Troy Thompson
- Ontario Regional Blood Coordinating Network (ORBCoN), Toronto, Ontario, Canada
| | - Alan Tinmouth
- Ottawa Hospital Centre for Transfusion Research, Ottawa Hospital and Ottawa Hospital Research Institute, Ottawa, Ontario, Canada.,Division of Hematology, Department of Medicine, University of Ottawa, Ottawa, Ontario, Canada
| | - Iris Perelman
- Ottawa Hospital Research Institute (OHRI), Ottawa, Ontario, Canada
| | - Robert Skeate
- Canadian Blood Services, Toronto, Ontario, Canada.,The University of Toronto Quality in Utilization, Education and Safety in Transfusion (QUEST) Research Program, Toronto, Ontario, Canada
| | - Amie T Kron
- The University of Toronto Quality in Utilization, Education and Safety in Transfusion (QUEST) Research Program, Toronto, Ontario, Canada.,Precision Diagnostics and Therapeutics Program, Sunnybrook Health Sciences Centre, Toronto, Ontario, Canada
| | - Jeannie Callum
- The University of Toronto Quality in Utilization, Education and Safety in Transfusion (QUEST) Research Program, Toronto, Ontario, Canada.,Department of Pathology and Molecular Medicine, Kingston Health Sciences Centre, Queen's University, Kingston, Ontario, Canada
| |
Collapse
|
4
|
McCormick M, Delaney M. Transfusion support: Considerations in pediatric populations. Semin Hematol 2020; 57:65-72. [PMID: 32892845 DOI: 10.1053/j.seminhematol.2020.07.003] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.4] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/04/2020] [Indexed: 01/19/2023]
Abstract
Over 400,000 units of blood and blood products are transfused to pediatric patients annually, yet only sparse high-quality data exist to guide the preparation and administration of blood products in this population. The direct application of data from studies in adult patients should be undertaken with caution, as there are dissimilarities in the pathology and physiology between adult and pediatric patients. We provide an overview of available evidence in the field of pediatric transfusion medicine, summarizing indications for blood product transfusion, thresholds for transfusion and indications for blood product modifications.
Collapse
Affiliation(s)
- Meghan McCormick
- Division of Hematology-Oncology, UPMC Children's Hospital of Pittsburgh, Pittsburgh, PA, USA
| | - Meghan Delaney
- Division of Pathology & Laboratory Medicine, Children's National Medical Center, Washington, DC, USA; Departments of Pathology & Pediatrics, The George Washington University Health Sciences, Washington, DC, USA.
| |
Collapse
|
5
|
Lieberman L. Reply to: Use of ROTEM in correction of unexpected oozing in a child with a preexisting normal coagulation profile undergoing splenectomy. Pediatr Blood Cancer 2018; 65:e27302. [PMID: 30009562 DOI: 10.1002/pbc.27302] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 06/08/2018] [Accepted: 06/08/2018] [Indexed: 11/06/2022]
Affiliation(s)
- Lani Lieberman
- Department of Clinical Pathology, University Health Network, Toronto, Ontario, Canada.,Department of Laboratory Medicine & Pathobiology, University of Toronto, Toronto, Ontario, Canada.,Department of Clinical Pathology, Sunnybrook Health Science Center, Toronto, Ontario, Canada
| |
Collapse
|