1
|
Kuckova S, Cejnar P, Santrucek J, Hynek R. Characterization of proteins in cultural heritage using MALDI–TOF and LC–MS/MS mass spectrometric techniques. PHYSICAL SCIENCES REVIEWS 2019. [DOI: 10.1515/psr-2018-0011] [Citation(s) in RCA: 8] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/22/2023]
Abstract
Abstract
Identification of proteinaceous materials in artworks is of high interest to restorers-conservators, art historians and archaeologists, because it helps to shed light on the used painting techniques, to attribute unknown artworks, to make conclusions on prehistoric diets, etc. The chapter is devoted to the mass spectrometry instrumentation, evaluation of obtained data and it is showing several examples of the application of matrix-assisted laser desorption/ionization–time-of-flight and liquid chromatography–electrospray ionization–quadrupole–time-of-flight mass spectrometers on cultural heritage samples.
Collapse
|
2
|
Wu Z, Xu N, Li W, Lin JM. A membrane separation technique for optimizing sample preparation of MALDI-TOF MS detection. CHINESE CHEM LETT 2019. [DOI: 10.1016/j.cclet.2018.01.048] [Citation(s) in RCA: 12] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/07/2023]
|
3
|
Rühl M, Schönborn S, Karas M. Detergent-assisted sample preparation for MALDI-MS: Investigation of octylglucoside and docecylmaltoside for matrix crystallization, on-plate digestion, and trypsin activity. JOURNAL OF MASS SPECTROMETRY : JMS 2018; 53:675-679. [PMID: 29787639 DOI: 10.1002/jms.4203] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.1] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 01/19/2018] [Revised: 04/17/2018] [Accepted: 05/11/2018] [Indexed: 06/08/2023]
Abstract
We show an easy and fast method for improved detection of lipophilic peptides with MALDI-MS utilizing the nonionic detergents n-octylglucoside and n-dodecylmaltoside (laurylmaltoside). Investigations comprised on-plate digestion of proteins with trypsin, detergent effects on the protease trypsin, and the changes in MALDI matrix crystallization. Investigations also exhibited a higher tryptic activity in trypsin activity assay of 139% when using laurylmaltoside as supplement. Crystallization changed toward a more homogeneous crystal distribution and especially trypsinized insulin spectra recorded with MALDI-MS showed improved detectability of lipophilic peptides.
Collapse
Affiliation(s)
- Michael Rühl
- Institute of Pharmaceutical Chemistry, Goethe University Frankfurt, Max-von-Laue-Straße 9, D-60438, Frankfurt, Germany
| | - Stefan Schönborn
- Institute of Pharmaceutical Chemistry, Goethe University Frankfurt, Max-von-Laue-Straße 9, D-60438, Frankfurt, Germany
| | - Michael Karas
- Institute of Pharmaceutical Chemistry, Goethe University Frankfurt, Max-von-Laue-Straße 9, D-60438, Frankfurt, Germany
| |
Collapse
|
4
|
Wu Z, Khan M, Mao S, Lin L, Lin JM. Combination of nano-material enrichment and dead-end filtration for uniform and rapid sample preparation in matrix-assisted laser desorption/ionization mass spectrometry. Talanta 2018; 181:217-223. [DOI: 10.1016/j.talanta.2018.01.016] [Citation(s) in RCA: 8] [Impact Index Per Article: 1.1] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/19/2017] [Revised: 12/30/2017] [Accepted: 01/07/2018] [Indexed: 11/15/2022]
|
5
|
Maus A, Mignon R, Basile F. Enhanced protein identification using graphite-modified MALDI plates for offline LC-MALDI-MS/MS bottom-up proteomics. Anal Biochem 2018; 545:31-37. [PMID: 29326070 DOI: 10.1016/j.ab.2018.01.002] [Citation(s) in RCA: 9] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/28/2017] [Revised: 12/22/2017] [Accepted: 01/02/2018] [Indexed: 10/18/2022]
Abstract
The use of offline liquid chromatography-matrix assisted laser desorption/ionization (LC-MALDI) tandem mass spectrometry (MS/MS) for bottom-up proteomics offers advantages in terms of cost, ease of use, and the time-decoupled nature of the separation step and the mass analysis. A method was developed to improve the capabilities of LC-MALDI-MS/MS in terms of protein identification in a bottom-up proteomic workflow. Enhanced protein identification is achieved by an increase in the MALDI signal intensity of the precursor peptides brought about by coating the MALDI plate with a thin film of graphite powder. Using the Escherichia coli proteome, it is demonstrated that the graphite-modified MALDI plates used in an offline LC-MALDI-MS/MS bottom-up protocol led to a 50-135% increase in the number of peptide identifications, and a concomitant 21%-105% increase in the number of proteins inferred. We identify factors that lead to improvements in peptide sequence identifications and in the number of unique proteins identified when compared to using an unmodified MALDI plate. These improvements are achieved using a low cost approach that it is easy to implement, requires no hardware/protocol modification, it is compatible with LC and adds no additional analysis time.
Collapse
Affiliation(s)
- Anthony Maus
- Department of Chemistry, University of Wyoming, 1000 E. University Ave., Laramie, WY 82072, United States
| | - Rudolph Mignon
- Department of Chemistry, University of Wyoming, 1000 E. University Ave., Laramie, WY 82072, United States
| | - Franco Basile
- Department of Chemistry, University of Wyoming, 1000 E. University Ave., Laramie, WY 82072, United States.
| |
Collapse
|
6
|
Revealing the composition of organic materials in polychrome works of art: the role of mass spectrometry-based techniques. Anal Bioanal Chem 2016; 408:6957-81. [DOI: 10.1007/s00216-016-9862-8] [Citation(s) in RCA: 15] [Impact Index Per Article: 1.7] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/10/2016] [Revised: 07/28/2016] [Accepted: 08/03/2016] [Indexed: 10/21/2022]
|
7
|
|
8
|
Rankin K, Mabury SA. Matrix normalized MALDI-TOF quantification of a fluorotelomer-based acrylate polymer. ENVIRONMENTAL SCIENCE & TECHNOLOGY 2015; 49:6093-6101. [PMID: 25866313 DOI: 10.1021/es505931v] [Citation(s) in RCA: 13] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 06/04/2023]
Abstract
The degradation of fluorotelomer-based acrylate polymers (FTACPs) has been hypothesized to serve as a source of the environmental contaminants, perfluoroalkyl carboxylates (PFCAs). Studies have relied on indirect measurement of presumed degradation products to evaluate the environmental fate of FTACPs; however, this approach leaves a degree of uncertainty. The present study describes the development of a quantitative matrix-assisted laser desorption/ionization time-of-flight (MALDI-TOF) mass spectrometry method as the first direct analysis method for FTACPs. The model FTACP used in this study was poly(8:2 FTAC-co-HDA), a copolymer of 8:2 fluorotelomer acrylate (8:2 FTAC) and hexadecyl acrylate (HDA). Instead of relying on an internal standard polymer, the intensities of 40 poly(8:2 FTAC-co-HDA) signals (911-4612 Da) were normalized to the signal intensity of a matrix-sodium cluster (659 Da). We termed this value the normalized polymer response (P(N)). By using the same dithranol solution for the sample preparation of poly(8:2 FTAC-co-HDA) standards, calibration curves with coefficient of determinations (R(2)) typically >0.98 were produced. When poly(8:2 FTAC-co-HDA) samples were prepared with the same dithranol solution as the poly(8:2 FTAC-co-HDA) standards, quantification to within 25% of the theoretical concentration was achieved. This approach minimized the sample-to-sample variability that typically plagues MALDI-TOF, and is the first method developed to directly quantify FTACPs.
Collapse
Affiliation(s)
- Keegan Rankin
- Department of Chemistry, University of Toronto, 80 St. George St., Toronto, Ontario Canada, M5S 3H6
| | - Scott A Mabury
- Department of Chemistry, University of Toronto, 80 St. George St., Toronto, Ontario Canada, M5S 3H6
| |
Collapse
|
9
|
On plate graphite supported sample processing for simultaneous lipid and protein identification by matrix assisted laser desorption ionization mass spectrometry. Talanta 2015; 137:161-6. [DOI: 10.1016/j.talanta.2015.01.030] [Citation(s) in RCA: 15] [Impact Index Per Article: 1.5] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/11/2014] [Revised: 01/19/2015] [Accepted: 01/23/2015] [Indexed: 01/27/2023]
|
10
|
Borisov RS, Polovkov NY, Zhilyaev DI, Esparza CA, Zaikin VG. Combination of graphite-assisted laser desorption/ionization (GALDI) mass spectrometry with thin layer chromatography. JOURNAL OF ANALYTICAL CHEMISTRY 2014. [DOI: 10.1134/s1061934814140032] [Citation(s) in RCA: 5] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 11/23/2022]
|
11
|
Identification of lipid- and protein-based binders in paintings by direct on-plate wet chemistry and matrix-assisted laser desorption ionization mass spectrometry. Anal Bioanal Chem 2014; 407:1015-22. [DOI: 10.1007/s00216-014-8359-6] [Citation(s) in RCA: 20] [Impact Index Per Article: 1.8] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/10/2014] [Revised: 11/18/2014] [Accepted: 11/19/2014] [Indexed: 11/27/2022]
|
12
|
Kobeissy FH, Gulbakan B, Alawieh A, Karam P, Zhang Z, Guingab-Cagmat JD, Mondello S, Tan W, Anagli J, Wang K. Post-genomics nanotechnology is gaining momentum: nanoproteomics and applications in life sciences. OMICS-A JOURNAL OF INTEGRATIVE BIOLOGY 2014; 18:111-31. [PMID: 24410486 DOI: 10.1089/omi.2013.0074] [Citation(s) in RCA: 18] [Impact Index Per Article: 1.6] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 01/25/2023]
Abstract
The post-genomics era has brought about new Omics biotechnologies, such as proteomics and metabolomics, as well as their novel applications to personal genomics and the quantified self. These advances are now also catalyzing other and newer post-genomics innovations, leading to convergences between Omics and nanotechnology. In this work, we systematically contextualize and exemplify an emerging strand of post-genomics life sciences, namely, nanoproteomics and its applications in health and integrative biological systems. Nanotechnology has been utilized as a complementary component to revolutionize proteomics through different kinds of nanotechnology applications, including nanoporous structures, functionalized nanoparticles, quantum dots, and polymeric nanostructures. Those applications, though still in their infancy, have led to several highly sensitive diagnostics and new methods of drug delivery and targeted therapy for clinical use. The present article differs from previous analyses of nanoproteomics in that it offers an in-depth and comparative evaluation of the attendant biotechnology portfolio and their applications as seen through the lens of post-genomics life sciences and biomedicine. These include: (1) immunosensors for inflammatory, pathogenic, and autoimmune markers for infectious and autoimmune diseases, (2) amplified immunoassays for detection of cancer biomarkers, and (3) methods for targeted therapy and automatically adjusted drug delivery such as in experimental stroke and brain injury studies. As nanoproteomics becomes available both to the clinician at the bedside and the citizens who are increasingly interested in access to novel post-genomics diagnostics through initiatives such as the quantified self, we anticipate further breakthroughs in personalized and targeted medicine.
Collapse
Affiliation(s)
- Firas H Kobeissy
- 1 Center for Neuroproteomics and Biomarkers Research, Department of Psychiatry, McKnight Brain Institute, University of Florida , Gainesville, Florida
| | | | | | | | | | | | | | | | | | | |
Collapse
|
13
|
Pabst M, Fagerer SR, Köhling R, Küster SK, Steinhoff R, Badertscher M, Wahl F, Dittrich PS, Jefimovs K, Zenobi R. Self-Aliquoting Microarray Plates for Accurate Quantitative Matrix-Assisted Laser Desorption/Ionization Mass Spectrometry. Anal Chem 2013; 85:9771-6. [DOI: 10.1021/ac4021775] [Citation(s) in RCA: 30] [Impact Index Per Article: 2.5] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/28/2022]
Affiliation(s)
- Martin Pabst
- Department
of Chemistry and Applied Biosciences, ETH Zürich, Wolfgang-Pauli-Strasse
10, 8093 Zürich, Switzerland
| | - Stephan R. Fagerer
- Department
of Chemistry and Applied Biosciences, ETH Zürich, Wolfgang-Pauli-Strasse
10, 8093 Zürich, Switzerland
| | - Rudolf Köhling
- Sigma-Aldrich, Industriestrasse 25, 9471 Buchs, Switzerland
| | - Simon K. Küster
- Department
of Chemistry and Applied Biosciences, ETH Zürich, Wolfgang-Pauli-Strasse
10, 8093 Zürich, Switzerland
| | - Robert Steinhoff
- Department
of Chemistry and Applied Biosciences, ETH Zürich, Wolfgang-Pauli-Strasse
10, 8093 Zürich, Switzerland
| | - Martin Badertscher
- Department
of Chemistry and Applied Biosciences, ETH Zürich, Wolfgang-Pauli-Strasse
10, 8093 Zürich, Switzerland
| | - Fabian Wahl
- Sigma-Aldrich, Industriestrasse 25, 9471 Buchs, Switzerland
| | - Petra S. Dittrich
- Department
of Chemistry and Applied Biosciences, ETH Zürich, Wolfgang-Pauli-Strasse
10, 8093 Zürich, Switzerland
| | - Konstantins Jefimovs
- Swiss Federal Laboratories for Material Science and Technology EMPA, Überlandstrasse 129, 8600 Dübendorf, Switzerland
| | - Renato Zenobi
- Department
of Chemistry and Applied Biosciences, ETH Zürich, Wolfgang-Pauli-Strasse
10, 8093 Zürich, Switzerland
| |
Collapse
|
14
|
Wan D, Gao M, Wang Y, Zhang P, Zhang X. A rapid and simple separation and direct detection of glutathione by gold nanoparticles and graphene-based MALDI-TOF-MS. J Sep Sci 2012; 36:629-35. [DOI: 10.1002/jssc.201200766] [Citation(s) in RCA: 22] [Impact Index Per Article: 1.7] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/12/2012] [Revised: 10/11/2012] [Accepted: 10/17/2012] [Indexed: 12/15/2022]
Affiliation(s)
- Dan Wan
- Department of Chemistry and Institute of Biomedical Sciences; Fudan University; Shanghai China
| | - Mingxia Gao
- Department of Chemistry and Institute of Biomedical Sciences; Fudan University; Shanghai China
| | - Yuhua Wang
- Department of Chemistry and Institute of Biomedical Sciences; Fudan University; Shanghai China
| | - Peng Zhang
- Department of Chemistry and Institute of Biomedical Sciences; Fudan University; Shanghai China
| | - Xiangmin Zhang
- Department of Chemistry and Institute of Biomedical Sciences; Fudan University; Shanghai China
| |
Collapse
|
15
|
Gorka J, Bahr U, Karas M. Graphite supported preparation (GSP) of α-cyano-4-hydroxycinnamic acid (CHCA) for matrix-assisted laser desorption/ionization mass spectrometry (MALDI-MS) for peptides and proteins. JOURNAL OF THE AMERICAN SOCIETY FOR MASS SPECTROMETRY 2012; 23:1949-1954. [PMID: 22993043 DOI: 10.1007/s13361-012-0478-8] [Citation(s) in RCA: 15] [Impact Index Per Article: 1.2] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 07/19/2012] [Revised: 08/10/2012] [Accepted: 08/10/2012] [Indexed: 06/01/2023]
Abstract
Graphite as MALDI matrix or in combination with other substances has been reported in recent years. Here, we demonstrate that graphite can be used as target coating supporting the crystallization of the α-cyano-4-hydroxycinnamic acid matrix. A conventional dried-droplet preparation of matrix and analyte solution on a graphite-coated metal target leads to a thin, uniform layer of cubic crystals with about 1 μm edge length. Commercially available graphite powder of 1-2 μm particle size is gently wiped over the target using a cotton Q-tip, leading to an ultra-thin, not-visible film. This surface modification considerably improves analysis of peptides and proteins for MALDI MS using conventional dried-droplet preparation. Compared with untreated targets, the signal intensities of standard peptides are up to eight times higher when using the graphite supported crystallization. The relative standard deviation in peak area of angiotensin II for sample amounts between 1 and 50 fmol is reduced to about 15 % compared with 45 % for untreated sample holders. For a quantification of 1 fmol of the peptide using an internal standard the coefficient of variation is reduced to 3.5 % from 8 %. The new graphite supported preparation (GSP) protocol is very simple and does not require any technical nor manual skills. All standard solvents for peptides and proteins can be used.
Collapse
Affiliation(s)
- Jan Gorka
- Institute of Pharmaceutical Chemistry, Cluster of Excellence Macromolecular Complexes, Goethe-University Frankfurt, Frankfurt a M, Germany
| | | | | |
Collapse
|
16
|
Weissenborn MJ, Wehner JW, Gray CJ, Šardzík R, Eyers CE, Lindhorst TK, Flitsch SL. Formation of carbohydrate-functionalised polystyrene and glass slides and their analysis by MALDI-TOF MS. Beilstein J Org Chem 2012; 8:753-62. [PMID: 23015824 PMCID: PMC3388864 DOI: 10.3762/bjoc.8.86] [Citation(s) in RCA: 9] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/10/2012] [Accepted: 05/02/2012] [Indexed: 01/25/2023] Open
Abstract
Glycans functionalised with hydrophobic trityl groups were synthesised and adsorbed onto polystyrene and glass slides in an array format. The adsorbed glycans could be analysed directly on these minimally conducting surfaces by MALDI-TOF mass spectrometry analysis after aluminium tape was attached to the underside of the slides. Furthermore, the trityl group appeared to act as an internal matrix and no additional matrix was necessary for the MS analysis. Thus, trityl groups can be used as simple hydrophobic, noncovalently linked anchors for ligands on surfaces and at the same time facilitate the in situ mass spectrometric analysis of such ligands.
Collapse
Affiliation(s)
- Martin J Weissenborn
- School of Chemistry & Manchester Interdisciplinary Biocentre, The University of Manchester, 131 Princess Street, Manchester, M1 7DN, United Kingdom
| | - Johannes W Wehner
- Otto Diels Institute of Organic Chemistry, Christiana Albertina University of Kiel, Otto-Hahn-Platz 3/4, 24098 Kiel, Germany
| | - Christopher J Gray
- School of Chemistry & Manchester Interdisciplinary Biocentre, The University of Manchester, 131 Princess Street, Manchester, M1 7DN, United Kingdom
| | - Robert Šardzík
- School of Chemistry & Manchester Interdisciplinary Biocentre, The University of Manchester, 131 Princess Street, Manchester, M1 7DN, United Kingdom
| | - Claire E Eyers
- School of Chemistry & Manchester Interdisciplinary Biocentre, The University of Manchester, 131 Princess Street, Manchester, M1 7DN, United Kingdom
| | - Thisbe K Lindhorst
- Otto Diels Institute of Organic Chemistry, Christiana Albertina University of Kiel, Otto-Hahn-Platz 3/4, 24098 Kiel, Germany
| | - Sabine L Flitsch
- School of Chemistry & Manchester Interdisciplinary Biocentre, The University of Manchester, 131 Princess Street, Manchester, M1 7DN, United Kingdom
| |
Collapse
|
17
|
Feldmeyer N, Wabnitz G, Leicht S, Luckner-Minden C, Schiller M, Franz T, Conradi R, Kropf P, Müller I, Ho AD, Samstag Y, Munder M. Arginine deficiency leads to impaired cofilin dephosphorylation in activated human T lymphocytes. Int Immunol 2012; 24:303-13. [DOI: 10.1093/intimm/dxs004] [Citation(s) in RCA: 44] [Impact Index Per Article: 3.4] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/07/2023] Open
|
18
|
Dong X, Cheng J, Li J, Wang Y. Graphene as a novel matrix for the analysis of small molecules by MALDI-TOF MS. Anal Chem 2010; 82:6208-14. [PMID: 20565059 PMCID: PMC2912442 DOI: 10.1021/ac101022m] [Citation(s) in RCA: 285] [Impact Index Per Article: 19.0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/22/2023]
Abstract
Graphene was utilized for the first time as a matrix for the analysis of low molecular weight compounds using matrix-assisted laser desorption/ionization time-of-flight mass spectrometry (MALDI-TOF MS). Polar compounds including amino acids, polyamines, anticancer drugs, and nucleosides could be successfully analyzed. Additionally, nonpolar compounds including steroids could be detected with high resolution and sensitivity. Compared with a conventional matrix, graphene exhibited a high desorption/ionization efficiency for nonpolar compounds. The graphene matrix functions as a substrate to trap analytes, and it transfers energy to the analytes upon laser irradiation, which allows for the analytes to be readily desorbed/ionized and interference of intrinsic matrix ions to be eliminated. The use of graphene as a matrix avoided the fragmentation of analytes and provided good reproducibility and a high salt tolerance, underscoring the potential application of graphene as a matrix for MALDI MS analysis of practical samples in complex sample matrixes. We also demonstrated that the use of graphene as an adsorbent for the solid-phase extraction of squalene could improve greatly the detection limit. This work not only opens a new field for applications of graphene, but also offers a new technique for high-speed analysis of low molecular weight compounds in areas such as metabolism research and natural product characterization.
Collapse
Affiliation(s)
- Xiaoli Dong
- Department of Chemistry, University of California, Riverside, California 92521-0403
| | - Jinsheng Cheng
- Department of Chemistry, Key Laboratory of Bioorganic Phosphorus Chemistry and Chemical Biology, Tsinghua University, Beijing, China 100084
| | - Jinghong Li
- Department of Chemistry, Key Laboratory of Bioorganic Phosphorus Chemistry and Chemical Biology, Tsinghua University, Beijing, China 100084
| | - Yinsheng Wang
- Department of Chemistry, University of California, Riverside, California 92521-0403
| |
Collapse
|
19
|
Kim JK, Murray KK. Matrix-assisted laser desorption/ionization with untreated silicon targets. RAPID COMMUNICATIONS IN MASS SPECTROMETRY : RCM 2009; 23:203-205. [PMID: 19086004 DOI: 10.1002/rcm.3842] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.1] [Reference Citation Analysis] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 05/27/2023]
|
20
|
Mazarin M, Phan TNT, Charles L. Using solvent-free sample preparation to promote protonation of poly(ethylene oxide)s with labile end-groups in matrix-assisted laser desorption/ionisation. RAPID COMMUNICATIONS IN MASS SPECTROMETRY : RCM 2008; 22:3776-3782. [PMID: 18988203 DOI: 10.1002/rcm.3798] [Citation(s) in RCA: 8] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 05/27/2023]
Abstract
Protonation is usually required to observe intact ions during matrix-assisted laser desorption/ionization (MALDI) of polymers containing fragile end-groups while cation adduction induces chain-end degradation. These polymers, generally obtained via living free radical polymerization techniques, are terminated with a functionality in which a bond is prone to homolytic cleavage, as required by the polymerization process. A solvent-free sample preparation method was used here to avoid salt contaminant from the solvent traditionally used in the dried-droplet MALDI procedure. Solvent-based and solvent-free sample preparations were compared for a series of three poly(ethylene oxide) polymers functionalized with a labile end-group in a nitroxide-mediated polymerization reaction, using 2,4,6-trihydroxyacetophenone (THAP) as the matrix without any added salt. Intact oligomer ions could only be produced as protonated molecules in solvent-free MALDI while sodium adducts of degraded polymers were formed from the dried-droplet samples. Although MALDI analysis was performed at the laser threshold, fragmentation of protonated macromolecules was still observed to occur. However, in contrast to sodiated molecules, dissociation of protonated oligomers does not involve the labile C--ON bond of the end-group. As the macromolecule size increased, protonation appeared to be less efficient and sodium adduction became the dominant ionization process, although no sodium salt was added in the preparation. Formation of sodiated degraded macromolecules would be dictated by increasing cation affinity as the size of the oligomers increases and would reveal the presence of salts at trace levels in the MALDI samples.
Collapse
Affiliation(s)
- Michael Mazarin
- Universités Aix-Marseille I, II et III - CNRS, UMR 6264, Spectrométries Appliquées à la Chimie Structurale, F-13397 Marseille Cedex 20, France
| | | | | |
Collapse
|
21
|
Ekström S, Wallman L, Helldin G, Nilsson J, Marko-Varga G, Laurell T. Polymeric integrated selective enrichment target (ISET) for solid-phase-based sample preparation in MALDI-TOF MS. JOURNAL OF MASS SPECTROMETRY : JMS 2007; 42:1445-1452. [PMID: 17960572 DOI: 10.1002/jms.1278] [Citation(s) in RCA: 15] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 05/25/2023]
Abstract
A polymer microfabricated proteomic sample preparation and MALDI MS sample presentation device, the integrated selective enrichment target (ISET), comprising an array of perforated nanovials is reported. Each perforated nanovial can be filled with selective extraction media (microbeads) for purification and concentration of protein/peptides prior to matrix-assisted laser desorption/ionization mass spectrometry (MALDI MS). The main areas covered are the influence of the molding-process-induced surface roughness and how to address the lack of inherent conductivity in the polyetheretherketone (PEEK) material for optimal MALDI MS readout. Application of the disposable polymeric ISET devices for solid-phase extraction and phosphopeptide capture is also demonstrated.
Collapse
Affiliation(s)
- Simon Ekström
- Department of Electrical Measurements, Lund Institute of Technology, S-221 00, Sweden.
| | | | | | | | | | | |
Collapse
|
22
|
Granvogl B, Plöscher M, Eichacker LA. Sample preparation by in-gel digestion for mass spectrometry-based proteomics. Anal Bioanal Chem 2007; 389:991-1002. [PMID: 17639354 DOI: 10.1007/s00216-007-1451-4] [Citation(s) in RCA: 72] [Impact Index Per Article: 4.0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/13/2007] [Revised: 06/14/2007] [Accepted: 06/20/2007] [Indexed: 10/23/2022]
Abstract
The proteomic characterization of proteins and protein complexes from cells and cell organelles is the next challenge for investigation of the cell. After isolation of the cell compartment, three steps have to be performed in the laboratory to yield information about the proteins present. The protein mixtures must be separated into single species, broken down into peptides, and, finally, identified by mass spectrometry. Most scientists engaged in proteomics separate proteins by electrophoresis. For characterization and identification of proteomes, mass spectrometry of peptides is the method of choice. To combine electrophoresis and mass spectrometry, sample preparation by "in-gel digestion" has been developed. Many procedures are available for in-gel digestion, which inspired us to review in-gel digestion approaches.
Collapse
Affiliation(s)
- Bernhard Granvogl
- Department für Biologie I, Ludwig-Maximilians-Universität, Menzinger Strasse 67, 80638, München, Germany
| | | | | |
Collapse
|
23
|
Abstract
Abstract
Background: Protein profiling with high-throughput sample preparation and MALDI-TOF MS analysis is a new potential tool for diagnosis of human diseases. However, analytical reproducibility is a significant challenge in MALDI protein profiling. This minireview summarizes studies of reproducibility of MALDI protein profiling and current approaches to improve its analytical performance.
Methods: The PubMed database was searched using combinations of the following search terms: MALDI, SELDI, reproducibility, variation, precision, peak intensity, quantification, peptide, biomarkers, and proteomics. Acceptance criteria were detailed reports on the reproducibility with MALDI protein profiling and studies describing efforts to improve the analytical performance with this technology.
Results: The reported intraexperiment CVs of the peak intensity vary highly between individual protein peaks, with the reported mean CV of the peak intensity varying among studies from 4% to 26%. There is additional interexperiment variation in peak intensity. Current approaches to improve the analytical performance of MALDI protein profiling include automated sample processing, extensive prefractionation strategies, immunocapture, prestructured target surfaces, standardized matrix (co)crystallization, improved MALDI-TOF MS instrument components, internal standard peptides, quality-control samples, replicate measurements, and algorithms for normalization and peak detection.
Conclusions: Further evaluation and optimization of MALDI-TOF MS is recommended before use in routine analysis.
Collapse
Affiliation(s)
- Jakob Albrethsen
- Glostrup Research Institute, Glostrup Hospital, Glostrup, Denmark.
| |
Collapse
|
24
|
Ibáñez AJ, Muck A, Svatos A. Dissipation of charge on MALDI-TOF polymeric chips using an electron-acceptor: analysis of proteins. JOURNAL OF MASS SPECTROMETRY : JMS 2007; 42:634-40. [PMID: 17370249 DOI: 10.1002/jms.1192] [Citation(s) in RCA: 7] [Impact Index Per Article: 0.4] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 05/14/2023]
Abstract
Disposable polymeric devices used for direct sample pretreatment/signal enhancement and MALDI-MS analyses of biomolecules suffer from the accumulation of electric charge and related positive mass shifts due to photoelectric effects on non-conductive surfaces after irradiation with lasers. The effects of surface charging on the mass shift of protein spectra during MALDI-TOF/MS measurements on copolymeric sample array chips were studied. Methyl viologen is used to monitor the development of charge and is demonstrated to be an effective electron scavenger. The use of such reducible species leads to increased accuracy, signal homogeneity, and resolution for mass spectral measurements of proteins in mixtures with sinapinic and 2,5-dihydroxybenzoic (DHB) acids. This approach can be used on a wide range of nonconductive support materials.
Collapse
Affiliation(s)
- Alfredo J Ibáñez
- Mass Spectrometry Research Group, Max Planck Institute for Chemical Ecology, 07745 Jena, Germany
| | | | | |
Collapse
|
25
|
Bodzon-Kulakowska A, Bierczynska-Krzysik A, Dylag T, Drabik A, Suder P, Noga M, Jarzebinska J, Silberring J. Methods for samples preparation in proteomic research. J Chromatogr B Analyt Technol Biomed Life Sci 2007; 849:1-31. [PMID: 17113834 DOI: 10.1016/j.jchromb.2006.10.040] [Citation(s) in RCA: 176] [Impact Index Per Article: 9.8] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/12/2006] [Accepted: 10/23/2006] [Indexed: 01/04/2023]
Abstract
Sample preparation is one of the most crucial processes in proteomics research. The results of the experiment depend on the condition of the starting material. Therefore, the proper experimental model and careful sample preparation is vital to obtain significant and trustworthy results, particularly in comparative proteomics, where we are usually looking for minor differences between experimental-, and control samples. In this review we discuss problems associated with general strategies of samples preparation, and experimental demands for these processes.
Collapse
Affiliation(s)
- Anna Bodzon-Kulakowska
- Department of Neurobiochemistry, Faculty of Chemistry, Jagiellonian University, Ingardena St. 3, 30-060 Krakow, Poland
| | | | | | | | | | | | | | | |
Collapse
|
26
|
Najam-ul-Haq M, Rainer M, Szabó Z, Vallant R, Huck CW, Bonn GK. Role of carbon nano-materials in the analysis of biological materials by laser desorption/ionization-mass spectrometry. ACTA ACUST UNITED AC 2007; 70:319-28. [PMID: 17188752 DOI: 10.1016/j.jbbm.2006.11.004] [Citation(s) in RCA: 55] [Impact Index Per Article: 3.1] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/22/2006] [Accepted: 11/01/2006] [Indexed: 11/21/2022]
Abstract
At present, carbon nano-materials are being utilized in various procedures, especially in laser desorption/ionization-mass spectrometry (LDI-MS) for analyzing a range of analytes, which include peptides, proteins, metabolites, and polymers. Matrix-oriented LDI-MS techniques are very well established, with weak organic acids as energy-absorbing substances. Carbon materials, such as nano-tubes and fullerenes are being successfully applied in the small-mass range, where routine matrices have strong background signals. In addition, the role of carbon nano-materials is very well established in the fractionation and purification fields. Modified diamond powder and surfaces are utilized in binding peptides and proteins from complex biological fluids and analyzed by matrix-assisted laser desorption/ionization (MALDI) time-of-flight (TOF) mass spectrometry (MS). Polylysine-coated diamond is used for solid-phase extraction to pre-concentrate DNA oligonucleotides. Graphite is useful for desalting, pre-concentration, and as energy-absorbing material (matrix) in desorption/ionization. Carbon nano-tubes in their different derivatized forms are used as matrix materials for the analysis of a range of analytes, such as carbohydrates, amino acids, peptides, proteins, and some environmental samples by LDI-MS. Fullerenes are modified in different ways to bind serum entities analyzed through MALDI/TOF-MS and are subsequently utilized in their identifications. In addition, the fullerenes are a promising matrix in LDI-MS, but improvements are needed.
Collapse
Affiliation(s)
- M Najam-ul-Haq
- Institute of Analytical Chemistry and Radiochemistry, Leopold-Franzens University, Innrain 52a, A-6020 Innsbruck, Austria
| | | | | | | | | | | |
Collapse
|
27
|
Berger-Nicoletti E, Wurm F, Kilbinger AFM, Frey H. Pencil Lead as a Matrix for MALDI-ToF Mass Spectrometry of Sensitive Functional Polymers. Macromolecules 2007. [DOI: 10.1021/ma062458c] [Citation(s) in RCA: 22] [Impact Index Per Article: 1.2] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/28/2022]
Affiliation(s)
- Elena Berger-Nicoletti
- Institut für Organische Chemie, Organische und Makromolekulare Chemie, Johannes Gutenberg-Universität Mainz, Duesbergweg 10-14, 55128 Mainz, Germany
| | - Frederik Wurm
- Institut für Organische Chemie, Organische und Makromolekulare Chemie, Johannes Gutenberg-Universität Mainz, Duesbergweg 10-14, 55128 Mainz, Germany
| | - Andreas F. M. Kilbinger
- Institut für Organische Chemie, Organische und Makromolekulare Chemie, Johannes Gutenberg-Universität Mainz, Duesbergweg 10-14, 55128 Mainz, Germany
| | - Holger Frey
- Institut für Organische Chemie, Organische und Makromolekulare Chemie, Johannes Gutenberg-Universität Mainz, Duesbergweg 10-14, 55128 Mainz, Germany
| |
Collapse
|
28
|
McComb ME, Perlman DH, Huang H, Costello CE. Evaluation of an on-target sample preparation system for matrix-assisted laser desorption/ionization time-of-flight mass spectrometry in conjunction with normal-flow peptide high-performance liquid chromatography for peptide mass fingerprint analyses. RAPID COMMUNICATIONS IN MASS SPECTROMETRY : RCM 2007; 21:44-58. [PMID: 17133622 DOI: 10.1002/rcm.2805] [Citation(s) in RCA: 13] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 05/12/2023]
Abstract
Large-scale mass spectrometry (MS)-based proteomic analyses require high-throughput sample preparation techniques due to the increasing numbers of samples that make up a typical proteomics experiment. Moreover, extensive sample pre-treatment steps are necessary prior to MS acquisition for even the most rapid and robust MS-based proteomics methodology, matrix-assisted laser desorption/ionization time-of-flight (MALDI-TOF) MS followed by peptide mass fingerprinting (PMF) analysis. These include sample purification and fractionation, removal of digestion buffers or solvents, and spotting of sample with matrix onto the MALDI target. These multiple steps of time-consuming sample handling can result in high overall analysis costs and the likelihood of sample contamination and loss. In order to overcome some of these limitations in sample processing, we have investigated the use of a novel, simple, inexpensive 96-well elastomeric array that affixes to a MALDI target to create an on-target 96-well plate that accommodates a high solution volume (ca. 200 microL), thereby enabling the on-target processing of samples for MALDI-TOFMS. We explored several factors that influence MALDI sample preparation: type of matrix, solution volume, solution organic composition, solution drying rates and matrix/analyte co-crystallization methods. We also investigated the use of the 96-well elastomeric device for coupling MALDI-TOFMS analysis directly to high flow rate (1 mL/min) reversed-phase (rp)-HPLC. By developing an optimized, robust sample preparation protocol, we were able to obtain mass spectra with a high signal-to-noise ratio from peptide standards present at the 50-fmol level in large starting volumes of solution. PMF analyses were possible from 1-pmol and 500-fmol protein-digest standards. Coupling the device to high-flow HPLC (750 microL/min) yielded a robust and semi-automated means to obtain enhanced MALDI-TOFMS data at 500 ng of protein digest. These methodologies developed for this simple, on-target, elastomeric device show promise for streamlining the sample preparation process from HPLC to MALDI-MS.
Collapse
Affiliation(s)
- Mark E McComb
- Cardiovascular Proteomics Center, Boston University School of Medicine, Boston, MA 02118-2646, USA.
| | | | | | | |
Collapse
|
29
|
Black C, Poile C, Langley J, Herniman J. The use of pencil lead as a matrix and calibrant for matrix-assisted laser desorption/ionisation. RAPID COMMUNICATIONS IN MASS SPECTROMETRY : RCM 2006; 20:1053-60. [PMID: 16498594 DOI: 10.1002/rcm.2408] [Citation(s) in RCA: 45] [Impact Index Per Article: 2.4] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 05/06/2023]
Abstract
Pencil lead is shown to be an effective matrix and calibrant in matrix-assisted laser desorption/ionisation (MALDI) mass spectrometry. Various groups of analytes, including peptides, polymers and actinide metals, can be readily ionised using MALDI when deposited onto a pencil lead matrix. The matrix is seen to have advantages in sample preparation relating to its hydrophobic properties and almost complete suppression of the matrix during analysis. Using pencil lead as a matrix is a quick and convenient method of qualitative analysis and has been shown to be quantitative for the isotope ratio analysis of actinide metals.
Collapse
|
30
|
Zabet-Moghaddam M, Heinzle E, Lasaosa M, Tholey A. Pyridinium-based ionic liquid matrices can improve the identification of proteins by peptide mass-fingerprint analysis with matrix-assisted laser desorption/ionization mass spectrometry. Anal Bioanal Chem 2005; 384:215-24. [PMID: 16252087 DOI: 10.1007/s00216-005-0130-6] [Citation(s) in RCA: 39] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/10/2005] [Revised: 09/14/2005] [Accepted: 09/22/2005] [Indexed: 10/25/2022]
Abstract
Matrix-assisted laser desorption/ionization mass spectrometry has become an indispensable tool for identification of proteins by peptide mass-fingerprint analysis. Selection of the matrix, addition of matrix additives, and sample-preparation techniques are known to affect the quality of the spectra and hence protein identification. We investigated the effect of pyridine as matrix additive for the commonly used crystalline matrix alpha-cyano-4-hydroxycinnamic acid (CCA), forming a pyridinium based ionic liquid matrix, on the mass spectra of synthetic peptides and tryptic protein digests. Beside the equimolar mixture of CCA and pyridine, the effect of addition of substoichiometric amounts of the base to the acid was tested. Optimum results in terms of signal-to-noise ratios, reduction of chemical noise, and reduced formation of alkali adducts and matrix clusters were observed for the matrix CCA-pyridine in the molar ratio 2:1. The optimized ionic liquid matrix was used for identification of tryptic digests of six model proteins and for identification of a protein extracted from a two-dimensional gel with the proteome of the bacterium Corynebacterium glutamicum, and shown to facilitate protein identification, yielding higher scores and increased sequence coverage compared with pure CCA. Thus CCA-Py 2:1 is a potential alternative for identification and characterization of proteins by peptide mass-fingerprint analysis.
Collapse
|
31
|
Current Awareness on Comparative and Functional Genomics. Comp Funct Genomics 2005. [PMCID: PMC2447491 DOI: 10.1002/cfg.425] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Download PDF] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/16/2022] Open
|