1
|
Solid supports for extraction and preconcentration of proteins and peptides in microfluidic devices: A review. Anal Chim Acta 2016; 955:1-26. [PMID: 28088276 DOI: 10.1016/j.aca.2016.12.017] [Citation(s) in RCA: 29] [Impact Index Per Article: 3.2] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/22/2016] [Revised: 12/02/2016] [Accepted: 12/07/2016] [Indexed: 01/08/2023]
Abstract
Determination of proteins and peptides is among the main challenges of today's bioanalytical chemistry. The application of microchip technology in this field is an exhaustively developed concept that aims to create integrated and fully automated analytical devices able to quantify or detect one or several proteins from a complex matrix. Selective extraction and preconcentration of targeted proteins and peptides especially from biological fluids is of the highest importance for a successful realization of these microsystems. Incorporation of solid structures or supports is a convenient solution employed to face these demands. This review presents a critical view on the latest achievements in sample processing techniques for protein determination using solid supports in microfluidics. The study covers the period from 2006 to 2015 and focuses mainly on the strategies based on microbeads, monolithic materials and membranes. Less common approaches are also briefly discussed. The reviewed literature suggests future trends which are discussed in the concluding remarks.
Collapse
|
2
|
Lin SL, Bai HY, Lin TY, Fuh MR. Microfluidic chip-based liquid chromatography coupled to mass spectrometry for determination of small molecules in bioanalytical applications. Electrophoresis 2012; 33:635-43. [PMID: 22451056 DOI: 10.1002/elps.201100380] [Citation(s) in RCA: 41] [Impact Index Per Article: 3.2] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/22/2022]
Abstract
The development and integration of microfabricated liquid chromatography (LC) microchips have increased dramatically in the last decade due to the needs of enhanced sensitivity and rapid analysis as well as the rising concern on reducing environmental impacts of chemicals used in various types of chemical and biochemical analyses. Recent development of microfluidic chip-based LC mass spectrometry (chip-based LC-MS) has played an important role in proteomic research for high throughput analysis. To date, the use of chip-based LC-MS for determination of small molecules, such as biomarkers, active pharmaceutical ingredients (APIs), and drugs of abuse and their metabolites, in clinical and pharmaceutical applications has not been thoroughly investigated. This mini-review summarizes the utilization of commercial chip-based LC-MS systems for determination of small molecules in bioanalytical applications, including drug metabolites and disease/tumor-associated biomarkers in clinical samples as well as adsorption, distribution, metabolism, and excretion studies of APIs in drug discovery and development. The different types of commercial chip-based interfaces for LC-MS analysis are discussed first and followed by applications of chip-based LC-MS on biological samples as well as the comparison with other LC-MS techniques.
Collapse
Affiliation(s)
- Shu-Ling Lin
- Department of Chemistry, Soochow University, Taipei, Taiwan
| | | | | | | |
Collapse
|
3
|
Abstract
AbstractThis review highlights the fundamentals and the most prominent advances in the field of HPLC instrumentation over the last decades. Fundamental aspects and practical considerations of column switching, conventional (heart-cut) and comprehensive two-dimensional LC are presented. Different aspects of microcolumn- and nanoliquid-chromatography are reviewed. Recent progress in column technology and the demands and developments in instrumentation and accessories for miniaturized LC are also discussed. In the field of miniaturization, particularly in chip-based nano-LC systems, some aspects on micro-fluidic chip fabrication, using particle-packed HPLC microchips or polymer-based monoliths, are addressed. An introduction to ultra performance LC (UPLC) is also presented.
Collapse
|
4
|
Daley AB, Xu Z, Oleschuk RD. Fluorous Monolith Specificity: The Effects of Polymer Density and Secondary Interactions on Column Performance and Amenability to Biological Samples. Anal Chem 2011; 83:1688-95. [DOI: 10.1021/ac102827t] [Citation(s) in RCA: 13] [Impact Index Per Article: 0.9] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/29/2022]
Affiliation(s)
- Adam B. Daley
- Department of Chemistry, Queen’s University, 90 Bader Lane Kingston, ON Canada K7L 3N6
| | - Zhenpo Xu
- Department of Chemistry, Queen’s University, 90 Bader Lane Kingston, ON Canada K7L 3N6
| | - Richard D. Oleschuk
- Department of Chemistry, Queen’s University, 90 Bader Lane Kingston, ON Canada K7L 3N6
| |
Collapse
|
5
|
Vázquez M, Paull B. Review on recent and advanced applications of monoliths and related porous polymer gels in micro-fluidic devices. Anal Chim Acta 2010; 668:100-13. [DOI: 10.1016/j.aca.2010.04.033] [Citation(s) in RCA: 61] [Impact Index Per Article: 4.1] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/22/2010] [Revised: 04/15/2010] [Accepted: 04/16/2010] [Indexed: 10/19/2022]
|
6
|
Gibson GTT, Mugo SM, Oleschuk RD. Nanoelectrospray emitters: trends and perspective. MASS SPECTROMETRY REVIEWS 2009; 28:918-936. [PMID: 19479726 DOI: 10.1002/mas.20248] [Citation(s) in RCA: 101] [Impact Index Per Article: 6.3] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 05/27/2023]
Abstract
The benefits of electrospray ionization are many, including sensitivity, robustness, simplicity and the ability to couple continuous flow methods with mass spectrometry. The technique has seen further improvement by lowering flow rates to the nanoelectrospray regime (<1,000 nL/min), where sample consumption is minimized and sensitivity increases. The move to nanoelectrospray has required a shift in the design of the electrospray source which has mostly involved the emitter itself. The emitter has seen an evolution in architecture as the shape and geometry of the device have proved pivotal in the formation of sufficiently small droplets for sensitive MS detection at these flow rates. There is a clear movement toward the development of emitters that produce multiple Taylor cones. Such multielectrospray emitters have been shown to provide enhanced sensitivity and sample utilization. This article reviews the development of nanoelectrospray emitters, including factors such as geometry and the manner of applying voltage. Designs for emitters that take advantage of multielectrospray are emphasized.
Collapse
Affiliation(s)
- Graham T T Gibson
- Department of Chemistry, Queen's University, Kingston, Ontario, Canada K7L 3N6
| | | | | |
Collapse
|
7
|
Iannacone JM, Ren S, Hatcher NG, Sweedler JV. Collecting peptide release from the brain using porous polymer monolith-based solid phase extraction capillaries. Anal Chem 2009; 81:5433-8. [PMID: 19485405 PMCID: PMC2810310 DOI: 10.1021/ac9005843] [Citation(s) in RCA: 15] [Impact Index Per Article: 0.9] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/28/2022]
Abstract
Porous polymer monolithic (PPM) columns are employed to collect and concentrate neuronal release from invertebrate and vertebrate model systems, prior to their characterization with mass spectrometry. The monoliths are fabricated in fused-silica capillaries from lauryl methacrylate (LMA) and ethylene glycol dimethacrylate (EDMA). The binding capacities for fluorescein and for fluorescently labeled peptides are on the order of nanomoles per millimeter of length of monolith material for a capillary with an inner diameter of 200 microm. To evaluate this strategy for collecting peptides from physiological solutions, angiotensin I and insulin in artificial seawater are loaded onto, and then released from, the monoliths after a desalination rinse, resulting in femtomole limits of detection via matrix-assisted laser desorption/ionization time-of-flight mass spectrometry. Positioned in the extracellular media near Aplysia californica bag cell neurons, upon electrical stimulation, these LMA-EDMA monoliths are also used to collect and concentrate peptide release, with egg-laying hormones and acidic peptide detected. In addition, the collection of several known peptides secreted from chemically stimulated mouse brain slices demonstrates their ability to collect releasates from a variety of neuronal tissues. When compared to collection approaches using individual beads placed on brain slices, the PPM capillaries offer greater binding capacity. Moreover, they maintain higher spatial resolution, compared to the larger-volume, solid-phase extraction collection strategies.
Collapse
Affiliation(s)
- Jamie M. Iannacone
- Department of Chemistry and the Beckman Institute for Advanced Science and Technology, University of Illinois at Urbana-Champaign, Urbana, Illinois 61801
| | - Shifang Ren
- Department of Chemistry and the Beckman Institute for Advanced Science and Technology, University of Illinois at Urbana-Champaign, Urbana, Illinois 61801
| | - Nathan G. Hatcher
- Department of Chemistry and the Beckman Institute for Advanced Science and Technology, University of Illinois at Urbana-Champaign, Urbana, Illinois 61801
| | - Jonathan V. Sweedler
- Department of Chemistry and the Beckman Institute for Advanced Science and Technology, University of Illinois at Urbana-Champaign, Urbana, Illinois 61801
| |
Collapse
|
8
|
Mair DA, Schwei TR, Dinio TS, Fréchet JMJ, Svec F. Use of photopatterned porous polymer monoliths as passive micromixers to enhance mixing efficiency for on-chip labeling reactions. LAB ON A CHIP 2009; 9:877-83. [PMID: 19294297 PMCID: PMC2790067 DOI: 10.1039/b816521a] [Citation(s) in RCA: 34] [Impact Index Per Article: 2.1] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 05/09/2023]
Abstract
We introduce a passive micromixer with novel architecture using photopatterned porous polymer monoliths (PPM) and demonstrate an improvement in mixing efficiency by monitoring the fluorescence of an on-chip labeling reaction. UV light was used to photopattern a periodic arrangement of PPM structures directly within the channel of a plastic microfluidic chip. By optimizing the composition of the polymerization solution and irradiation time we demonstrate the ability to photopattern PPM in regularly repeating 100 microm segments at the tee-junction of the disposable device. To evaluate the efficiency of this dual functional mixer-reactor fluorescamine and lysine were introduced in separate channels upstream of the tee-junction and the intensity of laser-induced fluorescence resulting from the fluorogenic labeling reaction was monitored. The fluorescence level after the photopatterned periodic monolith configuration was 22% greater than both an equivalent 1 cm continuous segment of PPM and an open channel. Results indicate that this periodic arrangement of PPM, with regularly spaced open areas between 100 microm plugs of PPM, is directly responsible for enhancing the mixing and overall rate of chemical reaction in the system. In addition to facilitating preparation of a dual functional mixer-reactor, the ability to accurately photopattern PPM is an enabling technology for seamlessly integrating multiple monoliths into a single device. This technology will be particularly important to proteomic applications requiring preconcentration, enzymatic digestion and two-dimensional separations.
Collapse
Affiliation(s)
| | - Thomas R. Schwei
- College of Chemistry, University of California, Berkeley, CA 94720, USA
| | - Theresa S. Dinio
- College of Chemistry, University of California, Berkeley, CA 94720, USA
| | - Jean M. J. Fréchet
- College of Chemistry, University of California, Berkeley, CA 94720, USA
- The Molecular Foundry, Lawrence Berkeley National Laboratory, Berkeley CA, USA. Fax: +1 510 486 7419; Tel. +1 510 486 7964; E-mail:
| | - Frantisek Svec
- The Molecular Foundry, Lawrence Berkeley National Laboratory, Berkeley CA, USA. Fax: +1 510 486 7419; Tel. +1 510 486 7964; E-mail:
| |
Collapse
|
9
|
Affiliation(s)
- Frantisek Svec
- Lawrence Berkeley National Laboratory, Molecular Foundry, Berkeley, CA 94720, USA.
| |
Collapse
|
10
|
Daley AB, Oleschuk RD. Development of fluorinated, monolithic columns for improved chromatographic separations of fluorous-tagged analytes. J Chromatogr A 2009; 1216:772-80. [DOI: 10.1016/j.chroma.2008.11.078] [Citation(s) in RCA: 23] [Impact Index Per Article: 1.4] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/03/2008] [Revised: 11/10/2008] [Accepted: 11/17/2008] [Indexed: 10/21/2022]
|
11
|
Koster S, Verpoorte E. A decade of microfluidic analysis coupled with electrospray mass spectrometry: an overview. LAB ON A CHIP 2007; 7:1394-1412. [PMID: 17960264 DOI: 10.1039/b709706a] [Citation(s) in RCA: 114] [Impact Index Per Article: 6.3] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 05/25/2023]
Abstract
This review presents a thorough overview covering the period 1997-2006 of microfluidic chips coupled to mass spectrometry through an electrospray interface. The different types of fabrication processes and materials used to fabricate these chips throughout this period are discussed. Three 'eras' of interfaces are clearly distinguished. The earliest approach involves spraying from the edge of a chip, while later devices either incorporate a standard fused-silica emitter inserted into the device or fully integrated emitters formed during chip fabrication. A summary of microfluidic-electrospray devices for performing separations and sample pretreatment steps before sample introduction into the mass spectrometer is also presented.
Collapse
Affiliation(s)
- Sander Koster
- Groningen Research Institute of Pharmacy, University of Groningen, Antonius Deusinglaan 1, 9713AV Groningen, The Netherlands.
| | | |
Collapse
|
12
|
Wang P, Chen Z, Chang HC. An integrated micropump and electrospray emitter system based on porous silica monoliths. Electrophoresis 2006; 27:3964-70. [PMID: 16983638 DOI: 10.1002/elps.200600120] [Citation(s) in RCA: 22] [Impact Index Per Article: 1.2] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/09/2022]
Abstract
The work presents the design of an integrated system consisting of a high-pressure electroosmotic (EO) micropump and a microporous monolithic emitter, which together generate a stable and robust electrospray. Both the micropump and electrospray emitter are fabricated using a sol-gel process. Upon application of an electric potential of sufficient amplitude (>2 kV), the pump delivers fluids with an electroosmotically induced high pressure (>1 atm). The same potential is also harnessed to electrostatically generate a stable electrospray at the porous emitter. Electrokinetic coupling between pump and spray produces spray features different from sprays pressurized by independent mechanical pumps. Four typical spray modes, each with different drop sizes and charge-to-mass ratios, are observed and have been characterized. Since the monolith is silica-based, this integrated device can be used for a variety of fluids, especially organic solvents, without the swelling and shrinking problems that are commonly encountered for polymer monoliths. The maximum pressure generated by a 100 microm id monolithic pump is 3 atm at an applied voltage of 5 kV. The flow rate can be adjusted in the range of 100 nL/min to 1 microL/min by changing the voltage. For a given applied voltage across the pump and emitter system, it is seen that there exists one unique flow rate for which flow balance is achieved between the delivery of liquid to the emitter by the pump and the liquid ejection from the emitter. Under such a condition, a stable Taylor cone is obtained. The principles that lead to these results are also discussed.
Collapse
Affiliation(s)
- Ping Wang
- Department of Chemical and Biomolecular Engineering, Center for Micro-fluidics and Medical Diagnostics, University of Notre Dame, Notre Dame, IN 46556, USA
| | | | | |
Collapse
|
13
|
Abstract
Considerable effort has been invested in the development of integrated microfluidic devices for fast and highly efficient proteomic studies. Among various fabrication techniques for the preparation of analytical components (separation columns, reactors, extractors, valves, etc.) in integrated microchips, in situ fabrication of monolithic media is receiving increasing attention. This is mainly due to the ease and simplicity of preparation of monolithic media and the availability of various precursors and chemistries. In addition, UV-initiated photopolymerization technique enables the incorporation of multiple analytical components into specified parts of a single microchip using photomasks. This review summarizes preparation methods for monolithic media and their application as microfluidic analytical components in microchips.
Collapse
Affiliation(s)
- Kyung Won Ro
- Department of Cell and Molecular Pharmacology and Experimental Therapeutics, Medical University of South Carolina, Charleston, SC 29425, USA
| | | | | |
Collapse
|
14
|
Bedair MF, Oleschuk RD. Fabrication of Porous Polymer Monoliths in Polymeric Microfluidic Chips as an Electrospray Emitter for Direct Coupling to Mass Spectrometry. Anal Chem 2006; 78:1130-8. [PMID: 16478104 DOI: 10.1021/ac0514570] [Citation(s) in RCA: 83] [Impact Index Per Article: 4.4] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/30/2022]
Abstract
Coupling of polymeric microfluidic devices to mass spectrometry is reported using porous polymer monoliths (PPM) as nanoelectrospray emitters. Lauryl acrylate-co-ethylene dimethacrylate porous polymer monolith was photopatterned for 5 mm at the end of the channel of microfluidic devices fabricated from three different polymeric substrate materials, including the following: poly(dimethylsiloxane) (PDMS), poly(methyl methacrylate) (PMMA), and cyclic olefin copolymer (COC). Spraying directly from the end of the chip removes any dead volume associated with inserted emitters or transfer lines, and the presence of multiple pathways in the PPM prevents the clogging of the channels, which is a common problem in conventional nanospray emitters. Spraying from a microfluidic channel having a PPM emitter produced a substantial increase in TIC stability and increased sensitivity by as much as 70x compared to spraying from an open end chip with no PPM. The performance of PPM emitter in COC, PMMA, and PDMS chips was compared in terms of stability and reproducibility of the electrospray. COC chips showed the highest reproducibility in terms of chip-to-chip performance, which can be attributed to the ease and reproducibility of the PPM formation due to the favorable optical and chemical properties of COC. We have further tested the performance of the COC chips by constant infusion of poly(propylene glycol) solution at organic content ranging from 10 to 90% methanol and at flow rates ranging from 50 to 1000 nL/min, showing optimum spraying conditions (RSD < 5%) at 50-70% organic content and at flow rates from 100 to 500 nL/min. The PPM sprayer was also used for protein preconcentration and desalting prior to mass spectrometric detection, and results were comparable with a chip spraying from an electrospray tip.
Collapse
Affiliation(s)
- Mohamed F Bedair
- Department of Chemistry, Queen's University, Kingston, Ontario, Canada K7L 3N6
| | | |
Collapse
|