1
|
Mikhail IE, Murray E, Bluett S, Astrakhantseva S, Paull B. Simultaneous separation and detection of monochloramine, nitrite, and nitrate by step-gradient mixed-mode ion chromatography: Translation from benchtop to portable ion chromatograph. Anal Chim Acta 2024; 1304:342557. [PMID: 38637041 DOI: 10.1016/j.aca.2024.342557] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/17/2023] [Revised: 03/26/2024] [Accepted: 03/27/2024] [Indexed: 04/20/2024]
Abstract
BACKGROUND Nitrite (NO2-) and nitrate (NO3-) can be produced in the distribution systems of chloraminated drinking water due to the nitrification of ammonia. The most applied inorganic chloramine for this purpose, namely monochloramine (NH2Cl), is also released into aquatic environments from water treatment plants' effluent and within industrial waste streams. Within the treatment process, the continuous monitoring of disinfectant levels is necessary to limit the harmful disinfectant by-product (DBP) formation. Currently, NH2Cl can interfere with nutrient analysis in water samples, and there are no analytical techniques available for the simultaneous analysis of NH2Cl, NO2-, and NO3-. RESULTS A green analytical method based on mixed-mode ion chromatography, specifically ion exchange and ion exclusion modes, was developed for the simultaneous separation and detection of NH2Cl, NO2-, and NO3-. The separation was achieved using a Dionex IonPac AG15 column guard column and a step gradient elution involving deionized water and 120.0 mM NaCl. The method was developed using a benchtop HPLC with a custom-made multi-wavelength UV absorbance detector with a 50-mm flow cell to enable the sensitive detection of NH2Cl, NO2-, and NO3- at 240 nm, 220 nm, and 215 nm, respectively. The developed method was then transferred to a portable ion chromatography (IC) system, the Aquamonitrix analyser. The total run time was less than 10 min for both systems. The benchtop HPLC method had a limit of detection (LOD) of 0.07 μg mL-1 as Cl2 for NH2Cl, 0.01 μg mL-1 for NO2-, and 0.03 μg mL-1 for NO3-. The LODs obtained using the portable Aquamonitrix analyser were found to be 0.36 μg mL-1 as Cl2, 0.02 μg mL-1, and 0.11 μg mL-1 for NH2Cl, NO2-, and NO3-, respectively. Excellent linearity (r ≥ 0.9999) was achieved using the portable analyser over the studied concentration ranges. The developed system was applied to the analysis of spiked municipal drinking water samples and showed excellent repeatability for the three analytes at three different concentration levels (RSD of triplicate recovery experiments ≤ 1.9 %). Moreover, the variation in retention time was negligible for the three target analytes with RSD ≤ 0.8 % over 12 runs. SIGNIFICANCE We are reporting the first ion chromatographic method for the simultaneous separation and detection of NH2Cl, NO2-, and NO3- in water samples. The monitoring of NH2Cl, NO2-, and NO3- is critical for the determination of disinfectant dosing, water quality, and nitrification status. The developed method can be applied using a benchtop HPLC or via the portable automated IC system to monitor for the three target compounds analysis in water treatment plants.
Collapse
Affiliation(s)
- Ibraam E Mikhail
- Australian Centre for Research on Separation Science (ACROSS), School of Natural Sciences (Chemistry), University of Tasmania, Hobart, Tasmania, 7001, Australia
| | - Eoin Murray
- Research & Development, Aquamonitrix Ltd., Tullow, Carlow, Ireland; Research & Development, T.E. Laboratories Ltd. (TelLab), Tullow, Carlow, Ireland
| | - Simon Bluett
- Research & Development, Aquamonitrix Ltd., Tullow, Carlow, Ireland
| | - Snezhana Astrakhantseva
- Australian Centre for Research on Separation Science (ACROSS), School of Natural Sciences (Chemistry), University of Tasmania, Hobart, Tasmania, 7001, Australia
| | - Brett Paull
- Australian Centre for Research on Separation Science (ACROSS), School of Natural Sciences (Chemistry), University of Tasmania, Hobart, Tasmania, 7001, Australia.
| |
Collapse
|
2
|
Peng F, Lu Y, Dong X, Wang Y, Li H, Yang Z. Advances and research needs for disinfection byproducts control strategies in swimming pools. JOURNAL OF HAZARDOUS MATERIALS 2023; 454:131533. [PMID: 37146331 DOI: 10.1016/j.jhazmat.2023.131533] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Subscribe] [Scholar Register] [Received: 01/05/2023] [Revised: 04/16/2023] [Accepted: 04/27/2023] [Indexed: 05/07/2023]
Abstract
The control of disinfection byproducts (DBPs) in swimming pools is of great significance due to the non-negligible toxicity and widespread existence of DBPs. However, the management of DBPs remains challenging as the removal and regulation of DBPs is a multifactorial phenomenon in pools. This study summarized recent studies on the removal and regulation of DBPs, and further proposed some research needs. Specifically, the removal of DBPs was divided into the direct removal of the generated DBPs and the indirect removal by inhibiting DBP formation. Inhibiting DBP formation seems to be the more effective and economically practical strategy, which can be achieved mainly by reducing precursors, improving disinfection technology, and optimizing water quality parameters. Alternative disinfection technologies to chlorine disinfection have attracted increasing attention, while their applicability in pools requires further investigation. The regulation of DBPs was discussed in terms of improving the standards on DBPs and their preccursors. The development of online monitoring technology for DBPs is essential for implementing the standard. Overall, this study makes a significant contribution to the control of DBPs in pool water by updating the latest research advances and providing detailed perspectives.
Collapse
Affiliation(s)
- Fangyuan Peng
- Center for Environment and Water Resources, College of Chemistry and Chemical Engineering, Central South University, Changsha 410083, PR China; Key Laboratory of Hunan Province for Water Environment and Agriculture Product Safety, Changsha 410083, PR China
| | - Yi Lu
- Center for Environment and Water Resources, College of Chemistry and Chemical Engineering, Central South University, Changsha 410083, PR China; Key Laboratory of Hunan Province for Water Environment and Agriculture Product Safety, Changsha 410083, PR China
| | - Xuelian Dong
- Center for Environment and Water Resources, College of Chemistry and Chemical Engineering, Central South University, Changsha 410083, PR China; Key Laboratory of Hunan Province for Water Environment and Agriculture Product Safety, Changsha 410083, PR China
| | - Yingyang Wang
- Center for Environment and Water Resources, College of Chemistry and Chemical Engineering, Central South University, Changsha 410083, PR China; Key Laboratory of Hunan Province for Water Environment and Agriculture Product Safety, Changsha 410083, PR China
| | - Haipu Li
- Center for Environment and Water Resources, College of Chemistry and Chemical Engineering, Central South University, Changsha 410083, PR China; Key Laboratory of Hunan Province for Water Environment and Agriculture Product Safety, Changsha 410083, PR China.
| | - Zhaoguang Yang
- Center for Environment and Water Resources, College of Chemistry and Chemical Engineering, Central South University, Changsha 410083, PR China; Key Laboratory of Hunan Province for Water Environment and Agriculture Product Safety, Changsha 410083, PR China.
| |
Collapse
|
3
|
Condensed Phase Membrane Introduction Mass Spectrometry: A Direct Alternative to Fully Exploit the Mass Spectrometry Potential in Environmental Sample Analysis. SEPARATIONS 2023. [DOI: 10.3390/separations10020139] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 02/22/2023] Open
Abstract
Membrane introduction mass spectrometry (MIMS) is a direct mass spectrometry technique used to monitor online chemical systems or quickly quantify trace levels of different groups of compounds in complex matrices without extensive sample preparation steps and chromatographic separation. MIMS utilizes a thin, semi-permeable, and selective membrane that directly connects the sample and the mass spectrometer. The analytes in the sample are pre-concentrated by the membrane depending on their physicochemical properties and directly transferred, using different acceptor phases (gas, liquid or vacuum) to the mass spectrometer. Condensed phase (CP) MIMS use a liquid as a medium, extending the range to new applications to less-volatile compounds that are challenging or unsuitable to gas-phase MIMS. It directly allows the rapid quantification of selected compounds in complex matrices, the online monitoring of chemical reactions (in real-time), as well as in situ measurements. CP-MIMS has expanded beyond the measurement of several organic compounds because of the use of different types of liquid acceptor phases, geometries, dimensions, and mass spectrometers. This review surveys advancements of CP-MIMS and its applications to several molecules and matrices over the past 15 years.
Collapse
|
4
|
Larsen FT, McPherson JN, McKenzie CJ, Lauritsen FR. An experimental laboratory reactor for quantitative kinetic studies of disinfection byproduct formation using membrane inlet mass spectrometry. RAPID COMMUNICATIONS IN MASS SPECTROMETRY : RCM 2022; 36:e9339. [PMID: 35733413 PMCID: PMC9286867 DOI: 10.1002/rcm.9339] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 05/05/2022] [Revised: 06/16/2022] [Accepted: 06/17/2022] [Indexed: 06/15/2023]
Abstract
RATIONALE The type and quantity of environmentally problematic disinfection byproducts (DBPs) produced during chlorination of water depend on the natural organic matter and organic contaminants that raw water contains, and on the operational conditions of the drinking water treatment process. There is a need for a fast and quantitative method that determines which DBPs are produced and monitors the chemical dynamics during a drinking water treatment. METHODS A small experimental chemical reactor (50 mL) was mounted directly onto the membrane inlet interface of a membrane inlet mass spectrometer (MIMS). In this setup, the membrane was the only separation between the reaction mixture in the chemical reactor and the open ion source of the mass spectrometer 2 cm away. Water samples to be chlorinated were placed in the reactor and the chlorination reaction was initiated by injection of hypochlorite. The formation of intermediates and products was monitored using either full-scan mass spectra or selected ion monitoring of relevant ions. RESULTS An algorithm for analyte quantification was successfully developed for analysis of the complex mixtures of phenol (a model for waterborne organic compounds), chlorinated intermediates and trihalomethane products which simultaneously pass the membrane into the mass spectrometer. The algorithm is based upon the combined use of standard addition and an internal standard, and all analytes could be quantified at nanomolar concentrations corresponding to realistic water treatment conditions. Experiments carried out in the temperature range 15-60°C showed that the reaction dynamics change with operational parameters, for example in tap versus deionized water. CONCLUSIONS We have successfully shown that an experimental laboratory reactor directly interfaced with a MIMS can be used for quantitative monitoring of the chemical dynamics during a water treatment. This technique could provide rapid assistance in the optimization of operating parameters for minimizing DBP production.
Collapse
Affiliation(s)
- Freja Troj Larsen
- Department of Physics, Chemistry and PharmacyUniversity of Southern DenmarkOdense MDenmark
| | - James Neill McPherson
- Department of Physics, Chemistry and PharmacyUniversity of Southern DenmarkOdense MDenmark
| | - Christine Joy McKenzie
- Department of Physics, Chemistry and PharmacyUniversity of Southern DenmarkOdense MDenmark
| | | |
Collapse
|
5
|
Mensah AT, Allard S, Berne F, Soreau S, Gallard H. Brominated trihalamines in chlorinated seawaters: Quantification of tribromamine and identification of bromochloramines by Membrane Introduction Mass Spectrometry. THE SCIENCE OF THE TOTAL ENVIRONMENT 2022; 830:154667. [PMID: 35314219 DOI: 10.1016/j.scitotenv.2022.154667] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 01/24/2022] [Revised: 03/09/2022] [Accepted: 03/15/2022] [Indexed: 06/14/2023]
Abstract
During chlorination of seawater, the presence of bromide and ammonia alters the speciation of the oxidant and lead to the formation of chlorinated and brominated amines. This can affect the effectiveness of the disinfection treatment and the formation of disinfection by-products released to the environment. In this study, a Membrane Introduction Mass Spectrometry (MIMS) analytical method was developed to differentiate brominated trihalamines (i.e. tribromamine NBr3, dibromochloramine NBr2Cl and bromodichloramine NBrCl2) in synthetic and natural chlorinated seawater. A mass-to-charge ratio of m/z = 253 corresponding to the parent ion was used for the quantification of NBr3 in absence of organic matter and the signal of the fragment at m/z = 177 was chosen in presence of high concentration of organic matter. Limits of detection were 0.23 μM (49 μg Cl2/L) and 0.18 μM (38 μg Cl2/L) for m/z 253 and m/z 177, respectively. Both NBr2Cl and NBrCl2 were monitored in chlorinated seawaters with their respective parent ion at m/z = 207 and m/z = 163 but were not quantified. MIMS results also showed that reaction of brominated trihalamines with natural organic matter (NOM) was a minor pathway for 1-2 mg C/L compared to their auto-decomposition in natural or synthetic seawater. Overall, MIMS was able to unambiguously differentiate and monitor brominated trihalamines for the first time in chlorinated seawater, which was not possible by using UV measurement, titration and colorimetric methods.
Collapse
Affiliation(s)
- Anette T Mensah
- Curtin Water Quality Research Centre, Department of Molecular and Life Science, Curtin University, GPO Box U1987, Perth, Western Australia 6845, Australia; Institut de Chimie des Milieux et des Matériaux de Poitiers IC2MP UMR 7285 CNRS Université de Poitiers, ENSI Poitiers, 1 rue Marcel Doré TSA 41105, 86 073 Cedex 9, Poitiers, France
| | - Sébastien Allard
- Curtin Water Quality Research Centre, Department of Molecular and Life Science, Curtin University, GPO Box U1987, Perth, Western Australia 6845, Australia
| | - Florence Berne
- Institut de Chimie des Milieux et des Matériaux de Poitiers IC2MP UMR 7285 CNRS Université de Poitiers, ENSI Poitiers, 1 rue Marcel Doré TSA 41105, 86 073 Cedex 9, Poitiers, France
| | - Sylvie Soreau
- EDF - Recherche et Développement, Laboratoire National d'Hydraulique et Environnement (LNHE), 6 quai Watier, 78401 Chatou Cedex, France
| | - Hervé Gallard
- Institut de Chimie des Milieux et des Matériaux de Poitiers IC2MP UMR 7285 CNRS Université de Poitiers, ENSI Poitiers, 1 rue Marcel Doré TSA 41105, 86 073 Cedex 9, Poitiers, France.
| |
Collapse
|
6
|
Tsamba L, Correc O, Couzinet A. +Chlorination by-products in indoor swimming pools: Development of a pilot pool unit and impact of operating parameters. ENVIRONMENT INTERNATIONAL 2020; 137:105566. [PMID: 32106046 DOI: 10.1016/j.envint.2020.105566] [Citation(s) in RCA: 5] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 09/26/2019] [Revised: 01/14/2020] [Accepted: 02/09/2020] [Indexed: 06/10/2023]
Abstract
Chlorine addition in swimming pools ensures the microbiological quality of the water and the bathers' safety. However, water chlorination is associated with disinfection byproducts (DBP) formation and adverse health effects. The impact of operating parameters and innovative water treatment systems on DBPs levels has been reported in several studies, but sampling campaign in real pools remain difficult to carry out, mainly due to unexpected attendance variations. This study presents the development of a pilot pool plant allowing to perform experiments under controlled and reproducible conditions. Bathers inputs were simulated both for the organic load and for the mechanical agitation of water. Two sampling campaigns were performed during the building of the pilot, before and after the hall was closed. Key operating parameters such as chlorine dose, water temperature and attendance were controlled and monitored. DBP levels in the pilot plant were representative of French indoor swimming pools and the impact of bathers' activity was visible on volatile DBPs. Furthermore, correlations could be stated between operating parameters and DBP levels. Stripping effectively reduced volatile DBP concentrations in water. Moreover, energy consumption data, which are usually very scarce in experimental studies, showed the influence of heat pump consumption on the global energy consumption.
Collapse
Affiliation(s)
- Lucie Tsamba
- Scientific and Technical Center for Buildings, 11 rue Henri Picherit, 44323 Nantes Cedex 3, France
| | - Olivier Correc
- Scientific and Technical Center for Buildings, 11 rue Henri Picherit, 44323 Nantes Cedex 3, France.
| | - Anthony Couzinet
- Scientific and Technical Center for Buildings, 11 rue Henri Picherit, 44323 Nantes Cedex 3, France
| |
Collapse
|