1
|
Meng L, Yao W, Wen L, Fu X, Qi Y, Volmer DA. Optimized liquid chromatography-tandem mass spectrometry protocol for enhanced detection of 45 pesticides in water and soil samples. RAPID COMMUNICATIONS IN MASS SPECTROMETRY : RCM 2024; 38:e9904. [PMID: 39223864 DOI: 10.1002/rcm.9904] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 06/19/2024] [Revised: 08/17/2024] [Accepted: 08/18/2024] [Indexed: 09/04/2024]
Abstract
RATIONALE The development of analytical screening techniques for pesticides is crucial for preventing and mitigating environmental contamination. Mass spectrometry-based screening methods differ based on the complexity of the sample matrix and the diversity of the target compounds. One of the major challenges is balancing cost reduction in the extraction process with the optimization of analytical results. This protocol introduces a universal and efficient scheme for the qualitative and quantitative schemes for 45 pesticides within a single analytical run. METHODS Water samples were extracted using an SPE column, with the pH adjusted to 7. Soil samples were processed using a modified QuEChERS method. The pretreatment for water samples emphasized selecting appropriate SPE columns and optimizing pH, while for soil samples, the focus was on choosing suitable extraction solvents and extraction salt packages. The enriched samples were then analyzed using liquid chromatography-tandem mass spectrometry (LC-MS/MS). The method was evaluated for accuracy, precision, detection limits, and matrix effects. RESULTS The method enabled the simultaneous detection of 45 pesticides within a 15-minute analysis period. SPE recoveries ranged from 56.1% to 118.8%. Instrumental detection limits varied between 0.02 and 1 pg, while method detection limits extended from 0.05 to 18.47 ng/l in soil and water matrices. The approach was successfully applied to water and soil samples, with the pesticide concentration ranging from 0.1 ng/L to 38 μg/L. CONCLUSIONS The protocol substantially enhances the characterization and quantification of 45 pesticides in environmental samples, achieving a remarkable reduction in detection limits by an order of magnitude compared to previous research. This method enables the simultaneous detection of pesticides in both water and soil matrices using a single system, addressing the challenges of using separate systems for different environmental media. Furthermore, this protocol provides a crucial theoretical foundation for managing and safeguarding against pesticide pollution.
Collapse
Affiliation(s)
- Lingchen Meng
- Institute of Surface-Earth System Science, School of Earth System Science, Tianjin University, Tianjin, China
| | - Wenrui Yao
- Institute of Surface-Earth System Science, School of Earth System Science, Tianjin University, Tianjin, China
| | - Ling Wen
- Institute of Surface-Earth System Science, School of Earth System Science, Tianjin University, Tianjin, China
| | - Xiaoli Fu
- Institute of Surface-Earth System Science, School of Earth System Science, Tianjin University, Tianjin, China
| | - Yulin Qi
- Institute of Surface-Earth System Science, School of Earth System Science, Tianjin University, Tianjin, China
- Tianjin Bohai Rim Coastal Earth Critical Zone National Observation and Research Station, Tianjin University, Tianjin, China
| | - Dietrich A Volmer
- Department of Chemistry, Humboldt-Universität zu Berlin, Berlin, Germany
| |
Collapse
|
2
|
Filigenzi MS. Mass spectrometry in animal health laboratories: recent history, current applications, and future directions. J Vet Diagn Invest 2024:10406387241270071. [PMID: 39175303 DOI: 10.1177/10406387241270071] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 08/24/2024] Open
Abstract
Mass spectrometry (MS) has long been considered a cornerstone technique in analytical chemistry. However, the use of MS in animal health laboratories (AHLs) has been limited, however, largely because of the expense involved in purchasing and maintaining these systems. Nevertheless, since ~2020, the use of MS techniques has increased significantly in AHLs. As expected, developments in new instrumentation have shown significant benefits in veterinary analytical toxicology as well as bacteriology. Creative researchers continue to push the boundaries of MS analysis, and MS now promises to impact disciplines other than toxicology and bacteriology. I include a short discussion of MS instrumentation, more detailed discussions of the MS techniques introduced since ~2020, and a variety of new techniques that promise to bring the benefits of MS to disciplines such as virology and pathology.
Collapse
Affiliation(s)
- Michael S Filigenzi
- California Animal Health and Food Safety Laboratory, University of California-Davis, Davis, CA, USA
| |
Collapse
|
3
|
Domínguez-García P, Fernández-Ruano L, Báguena J, Cuadros J, Gómez-Canela C. Assessing the pharmaceutical residues as hotspots of the main rivers of Catalonia, Spain. ENVIRONMENTAL SCIENCE AND POLLUTION RESEARCH INTERNATIONAL 2024; 31:44080-44095. [PMID: 38926308 DOI: 10.1007/s11356-024-33967-7] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 02/13/2024] [Accepted: 06/07/2024] [Indexed: 06/28/2024]
Abstract
The global increase in pharmaceutical consumption, driven by factors such as aging populations and chronic diseases, has raised concerns regarding the environmental impact of pharmaceutical contaminants. Europe, and more specifically Catalonia (Spain), exhibits high pharmaceutical consumption rates, potentially exacerbating environmental contamination. Pharmaceuticals enter rivers through various pathways, persisting after wastewater treatment plants and posing risks to aquatic organisms and human health. Llobregat and Besòs Rivers in Catalonia, crucial water sources, demonstrate detectable pharmaceutical levels, necessitating comprehensive analysis. Liquid chromatography-tandem mass spectrometry (LC-MS/MS) proves effective in detecting pharmaceutical residues, facilitating their risk assessment. This paper reviews the occurrence, fate, and risks associated with 78 pharmaceuticals and metabolite in Llobregat and Besòs Rivers, using LC-MS/MS for analysis. Understanding pharmaceutical impacts on Catalonian River ecosystems is essential for developing mitigation strategies.
Collapse
Affiliation(s)
- Pol Domínguez-García
- Department of Analytical and Applied Chemistry, School of Engineering, Institut Químic de Sarrià-Universitat Ramon Llull, Via Augusta 390, 08017, Barcelona, Spain
| | - Laura Fernández-Ruano
- Department of Quantitative Methods, School of Engineering, Institut Químic de Sarrià-Universitat Ramon Llull, Via Augusta 390, 08017, Barcelona, Spain
| | - Judith Báguena
- Department of Analytical and Applied Chemistry, School of Engineering, Institut Químic de Sarrià-Universitat Ramon Llull, Via Augusta 390, 08017, Barcelona, Spain
| | - Jordi Cuadros
- Department of Quantitative Methods, School of Engineering, Institut Químic de Sarrià-Universitat Ramon Llull, Via Augusta 390, 08017, Barcelona, Spain
| | - Cristian Gómez-Canela
- Department of Analytical and Applied Chemistry, School of Engineering, Institut Químic de Sarrià-Universitat Ramon Llull, Via Augusta 390, 08017, Barcelona, Spain.
| |
Collapse
|
4
|
Yao W, Qi Y, Han Y, Ge J, Dong Y, Wang J, Yi Y, Volmer DA, Li SL, Fu P. Seasonal variation and dissolved organic matter influence on the distribution, transformation, and environmental risk of pharmaceuticals and personal care products in coastal zone: A case study of Tianjin, China. WATER RESEARCH 2024; 249:120881. [PMID: 38016225 DOI: 10.1016/j.watres.2023.120881] [Citation(s) in RCA: 6] [Impact Index Per Article: 6.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 04/18/2023] [Revised: 10/26/2023] [Accepted: 11/14/2023] [Indexed: 11/30/2023]
Abstract
Pharmaceuticals and personal care products (PPCPs) are emerging contaminants that have raised urgent environmental issues. The dissolved organic matter (DOM) plays a pivotal role on PPCPs' migration and transformation. To obtain a comprehensive understanding of the occurrence and distribution of PPCPs, a seasonal sampling focused on the riverine system in coastal zone, Tianjin, Bohai Rim was conducted. The distribution and transformation of thirty-three PPCPs and their interaction with DOM were investigated, and their sources and ecological risks were further evaluated. The total concentration of PPCPs ranges from 0.01 to 197.20 μg/L, and such value is affected by regional temperature, DOM and land use types. PPCPs migration at soil-water interface is controlled by temperature, sunlight, water flow and DOM. PPCPs have a high affinity to the protein-like DOM, while the humus-like DOM plays a negative influence and facilitates PPCPs' degradation. It is also found that protein-like DOM can represent point source pollution, while humus-like substances indicate non-point source (NPS) emission. Specific PPCPs can be used as markers to trace the source of domestic discharge. Additionally, daily use PPCPs such as ketoprofen, caffeine and iopromide are estimated to be the main risk substances, and their ecological risk varies on space, season and river hydraulic condition.
Collapse
Affiliation(s)
- Wenrui Yao
- Institute of Surface-Earth System Science, School of Earth System Science, Tianjin University, Tianjin, China
| | - Yulin Qi
- Institute of Surface-Earth System Science, School of Earth System Science, Tianjin University, Tianjin, China; Tianjin Bohai Rim Coastal Earth Critical Zone National Observation and Research Station, Tianjin University, Tianjin, China; Haihe Laboratory of Sustainable Chemical Transformations, Tianjin, China.
| | - Yufu Han
- Institute of Surface-Earth System Science, School of Earth System Science, Tianjin University, Tianjin, China
| | - Jinfeng Ge
- Institute of Surface-Earth System Science, School of Earth System Science, Tianjin University, Tianjin, China
| | - Yuanyuan Dong
- Institute of Surface-Earth System Science, School of Earth System Science, Tianjin University, Tianjin, China
| | - Jianwen Wang
- Institute of Surface-Earth System Science, School of Earth System Science, Tianjin University, Tianjin, China
| | - Yuanbi Yi
- Institute of Surface-Earth System Science, School of Earth System Science, Tianjin University, Tianjin, China; Department of Ocean Science and Center for Ocean Research in Hong Kong and Macau, The Hong Kong University of Science and Technology, Hong Kong, Hong Kong SAR, China
| | - Dietrich A Volmer
- Department of Chemistry, Humboldt-Universität zu Berlin, Berlin 12489, Germany
| | - Si-Liang Li
- Institute of Surface-Earth System Science, School of Earth System Science, Tianjin University, Tianjin, China; Tianjin Bohai Rim Coastal Earth Critical Zone National Observation and Research Station, Tianjin University, Tianjin, China; Haihe Laboratory of Sustainable Chemical Transformations, Tianjin, China
| | - Pingqing Fu
- Institute of Surface-Earth System Science, School of Earth System Science, Tianjin University, Tianjin, China; Tianjin Bohai Rim Coastal Earth Critical Zone National Observation and Research Station, Tianjin University, Tianjin, China; Haihe Laboratory of Sustainable Chemical Transformations, Tianjin, China
| |
Collapse
|
5
|
Becker RW, Cardoso RM, Dallegrave A, Ruiz-Padillo A, Sirtori C. Quantification of pharmaceuticals in hospital effluent: Weighted ranking of environmental risk using a fuzzy hybrid multicriteria method. CHEMOSPHERE 2023; 338:139368. [PMID: 37406941 DOI: 10.1016/j.chemosphere.2023.139368] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 03/28/2023] [Revised: 05/28/2023] [Accepted: 06/27/2023] [Indexed: 07/07/2023]
Abstract
An analytical method for quantification of seventeen pharmaceuticals and one metabolite was validated and applied in the analysis of hospital effluent samples. Two different sampling strategies were used: seasonal sampling, with 7 samples collected bimonthly; and hourly sampling, with 12 samples collected during 12 h. Thus, the variability was both seasonal and within the same day. High variability was observed in the measured concentrations of the pharmaceuticals and the metabolite. The quantification method, performed using weighted linear regression model, demonstrated results of average concentrations in seasonal samples ranged between 0.19 μgL-1 (carbamazepine) and higher than 61.56 μgL-1 (acetaminophen), while the hourly samples showed average concentrations between 0.07 μgL-1 (diazepam) and higher than 54.91 μgL-1 (acetaminophen). It is described as higher because the maximum concentration of the calibration curve took into account the dilution factor provided by DLLME. The diurnal results showed a trend towards higher concentrations in the first and last hours of sampling. The risk quotient (RQ) was calculated using organisms from three different trophic levels, for all the analytes quantified in the samples. Additionally, in order to understand the level of importance of each RQ, an expert panel was established, with contributions from 23 specialists in the area. The results were analyzed using a hybrid decision-making approach based on a Fuzzy Analytic Hierarchy Process (FAHP) and the Technique for Order Preference by Similarity to Ideal Solution (TOPSIS) method, in order to rank the compounds by environmental risk priority. The compounds of greatest concern were losartan, acetaminophen, 4-aminoantipyrine, sulfamethoxazole, and metoclopramide. Comparison of the environmental risk priority ranking with the potential human health risk was performed by applying the same multicriteria approach, with the prediction of endpoints using in silico (Q)SAR models. The results obtained suggested that sulfamethoxazole and acetaminophen were the most important analytes to be considered for monitoring.
Collapse
Affiliation(s)
- Raquel Wielens Becker
- Instituto de Química, Universidade Federal do Rio Grande do Sul, Av. Bento Gonçalves, 9500, Porto Alegre, RS, Brazil
| | - Renata Martins Cardoso
- Instituto de Química, Universidade Federal do Rio Grande do Sul, Av. Bento Gonçalves, 9500, Porto Alegre, RS, Brazil
| | - Alexsandro Dallegrave
- Instituto de Química, Universidade Federal do Rio Grande do Sul, Av. Bento Gonçalves, 9500, Porto Alegre, RS, Brazil
| | | | - Carla Sirtori
- Instituto de Química, Universidade Federal do Rio Grande do Sul, Av. Bento Gonçalves, 9500, Porto Alegre, RS, Brazil.
| |
Collapse
|
6
|
Rizzarelli P, Rapisarda M. Matrix-Assisted Laser Desorption and Electrospray Ionization Tandem Mass Spectrometry of Microbial and Synthetic Biodegradable Polymers. Polymers (Basel) 2023; 15:polym15102356. [PMID: 37242931 DOI: 10.3390/polym15102356] [Citation(s) in RCA: 3] [Impact Index Per Article: 3.0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/04/2023] [Revised: 05/10/2023] [Accepted: 05/16/2023] [Indexed: 05/28/2023] Open
Abstract
The in-depth structural and compositional investigation of biodegradable polymeric materials, neat or partly degraded, is crucial for their successful applications. Obviously, an exhaustive structural analysis of all synthetic macromolecules is essential in polymer chemistry to confirm the accomplishment of a preparation procedure, identify degradation products originating from side reactions, and monitor chemical-physical properties. Advanced mass spectrometry (MS) techniques have been increasingly applied in biodegradable polymer studies with a relevant role in their further development, valuation, and extension of application fields. However, single-stage MS is not always sufficient to identify unambiguously the polymer structure. Thus, tandem mass spectrometry (MS/MS) has more recently been employed for detailed structure characterization and in degradation and drug release monitoring of polymeric samples, among which are biodegradable polymers. This review aims to run through the investigations carried out by the soft ionization technique matrix-assisted laser desorption/ionization mass spectrometry (MALDI-MS) and electrospray ionization mass spectrometry (ESI-MS) MS/MS in biodegradable polymers and present the resulting information.
Collapse
Affiliation(s)
- Paola Rizzarelli
- Institute for Polymers, Composites and Biomaterials, Consiglio Nazionale delle Ricerche (CNR), Via Paolo Gaifami 18, 95126 Catania, Italy
| | - Marco Rapisarda
- Institute for Polymers, Composites and Biomaterials, Consiglio Nazionale delle Ricerche (CNR), Via Paolo Gaifami 18, 95126 Catania, Italy
| |
Collapse
|
7
|
Ge J, Qi Y, Yao W, Yuan D, Hu Q, Ma C, Volmer DA, Liu CQ. Identification of Trace Components in Sauce-Flavor Baijiu by High-Resolution Mass Spectrometry. Molecules 2023; 28:molecules28031273. [PMID: 36770938 PMCID: PMC9920578 DOI: 10.3390/molecules28031273] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/29/2022] [Revised: 01/20/2023] [Accepted: 01/25/2023] [Indexed: 01/31/2023] Open
Abstract
Sauce-flavor Baijiu is one of the most complex and typical types of traditional Chinese liquor, whose trace components have an important impact on its taste and quality. Fourier transform ion cyclotron resonance mass spectrometry (FT-ICR MS) is one of the most favorable analytical tools to reveal trace molecular components in complex samples. This study analyzed the chemical diversity of several representative sauce-flavor Baijiu using the combination of electrospray ionization (ESI) and FT-ICR MS. The results showed that ESI+ and ESI- exhibited different chemical features characteristic of trace components. Overall, sauce-flavor Baijiu was dominated by CHO class compounds, and the main specific compound types were aliphatic, highly unsaturated with low oxygen, and peptide-like compounds. The mass spectral parameters resolved by FT-ICR MS of several well-known brands were relatively similar, whereas the greatest variability was observed from an internally supplied brand. This study provides a new perspective on the mass spectrometry characteristics of trace components of sauce-flavor Baijiu and offers a theoretical foundation for further optimization of the gradients in Baijiu.
Collapse
Affiliation(s)
- Jinfeng Ge
- Institute of Surface-Earth System Science, School of Earth System Science, Tianjin University, Tianjin 300072, China
| | - Yulin Qi
- Institute of Surface-Earth System Science, School of Earth System Science, Tianjin University, Tianjin 300072, China
- Tianjin Key Laboratory of Earth Critical Zone Science and Sustainable Development in Bohai Rim, Tianjin University, Tianjin 300072, China
- Correspondence:
| | - Wenrui Yao
- Institute of Surface-Earth System Science, School of Earth System Science, Tianjin University, Tianjin 300072, China
| | - Daohe Yuan
- Institute of Surface-Earth System Science, School of Earth System Science, Tianjin University, Tianjin 300072, China
| | - Qiaozhuan Hu
- Institute of Surface-Earth System Science, School of Earth System Science, Tianjin University, Tianjin 300072, China
| | - Chao Ma
- Institute of Surface-Earth System Science, School of Earth System Science, Tianjin University, Tianjin 300072, China
| | - Dietrich A. Volmer
- Department of Chemistry, Humboldt-Universität zu Berlin, 12489 Berlin, Germany
| | - Cong-Qiang Liu
- Institute of Surface-Earth System Science, School of Earth System Science, Tianjin University, Tianjin 300072, China
- Tianjin Key Laboratory of Earth Critical Zone Science and Sustainable Development in Bohai Rim, Tianjin University, Tianjin 300072, China
| |
Collapse
|
8
|
Yao W, Ge J, Hu Q, Ma J, Yuan D, Fu X, Qi Y, Volmer DA. An advanced LC-MS/MS protocol for simultaneous detection of pharmaceuticals and personal care products in the environment. RAPID COMMUNICATIONS IN MASS SPECTROMETRY : RCM 2023; 37:e9397. [PMID: 36098176 DOI: 10.1002/rcm.9397] [Citation(s) in RCA: 2] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 07/13/2022] [Revised: 08/27/2022] [Accepted: 09/07/2022] [Indexed: 06/15/2023]
Abstract
RATIONALE The development of appropriate analytical screening techniques for pharmaceuticals and personal care products (PPCPs) is the basis for studying the distribution and environmental impact of emerging contaminants (ECs). Mass spectrometry-based screening methods vary with the complexity of the target compounds. It is challenging to balance both positive and negative ion quantification with a low detection limit. To establish a set of experimental methods including extraction, chromatography-separation and mass spectrometry screening is one of the most important topics in PPCP research. This paper describes a universal and efficient qualification and quantification protocol for the simultaneous detection of 34 PPCPs in different environmental samples in a single analytical data acquisition run. METHODS Thirty-four representative PPCPs, which are widely distributed in the environment with high ecological toxicity and complex chemical structures, were selected as representative target ECs. The extraction of the target PPCPs was achieved using only one solid-phase extraction cartridge without the need to adjust the pH of samples. The enriched samples were detected by LC-MS/MS in both positive and negative ion modes simultaneously. The protocol was evaluated based on the accuracy, precision, detection limits and matrix effects. RESULTS This method achieved simultaneous detection of PPCPs in both positive and negative ion modes, with a single analytical cycle of 12 min. The observed SPE recoveries were between 40% and 115%. The instrumental detection limits (IDL) varied from 0.01 to 1 pg, and the method detection limits (MDL) were between 0.002 and 3.323 ng/l in different matrices. Most of the PPCPs were subjected to matrix suppression below 30%. The method was successfully applied for quantitative analysis of the PPCPs in different environmental samples, including river samples, wastewater treatment plant (WWTP) samples and soil samples. CONCLUSIONS This protocol developed a rapid and efficient detection method to simultaneous qualitative and quantitative 34 representative PPCPs in the environment. The IDL ranged from 0.01 to 1 pg and the MDL ranged from 0.002 to 3.323 ng/l in different matrices. The detection limit was one order of magnitude lower compared to previous studies. The protocol also provided a wide application range for different environmental matrices, which permitted the migration and transformation of PPCPs to be explored.
Collapse
Affiliation(s)
- Wenrui Yao
- Institute of Surface-Earth System Science, School of Earth System Science, Tianjin University, Tianjin, China
| | - Jinfeng Ge
- Institute of Surface-Earth System Science, School of Earth System Science, Tianjin University, Tianjin, China
| | - Qiaozhuan Hu
- Institute of Surface-Earth System Science, School of Earth System Science, Tianjin University, Tianjin, China
| | - Jingying Ma
- Institute of Surface-Earth System Science, School of Earth System Science, Tianjin University, Tianjin, China
| | - Daohe Yuan
- Institute of Surface-Earth System Science, School of Earth System Science, Tianjin University, Tianjin, China
| | - Xiaoli Fu
- Institute of Surface-Earth System Science, School of Earth System Science, Tianjin University, Tianjin, China
| | - Yulin Qi
- Institute of Surface-Earth System Science, School of Earth System Science, Tianjin University, Tianjin, China
- Tianjin Bohai Rim Coastal Earth Critical Zone National Observation and Research Station, Tianjin University, Tianjin, China
| | - Dietrich A Volmer
- Department of Chemistry, Humboldt-Universität zu Berlin, Berlin, Germany
| |
Collapse
|