1
|
Kaneoka T, Imagama T, Okazaki T, Matsuki Y, Kawakami T, Yamazaki K, Sakai T. Evaluation of the reproducibility of preoperative three-dimensional computed tomography planning for posterolateral approach total hip arthroplasty. J Artif Organs 2024; 27:146-153. [PMID: 37081208 DOI: 10.1007/s10047-023-01396-x] [Citation(s) in RCA: 1] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/18/2023] [Accepted: 04/12/2023] [Indexed: 04/22/2023]
Abstract
The anteversion of the stem is occasionally intentionally changed by the surgeon for patients with smaller femoral neck anteversion during total hip arthroplasty (THA). However, the reproducibility of preoperative planning with increasing anteversion has been rarely assessed. The present study investigated it using two types of stems. This retrospective study included patients who underwent primary posterolateral THA using taper-wedge (TS group; 73 hips) and anatomical (AS group; 70 hips) stems. Characteristics of sex and age were matched in the two groups by propensity score matching. In both groups, the relationship between the preoperative three-dimensional planning and postoperative stem position, and the relationship between postoperative stem position and femoral neck anteversion (FNA) were evaluated. In the TS group, there were no significant differences in average stem anteversion (SA) between preoperative planning and postoperative placement (36.1° ± 7.0° and 36.6° ± 11.1°, respectively: p = 0.651). The absolute error of SA was 8.1° ± 6.4°. In the AS group, the postoperative SA was significantly smaller than the preoperative planning SA (22.7° ± 11.6° and 30.0° ± 9.3°, respectively: p < 0.001). The absolute error of SA was 9.0° ± 5.8°. The postoperative SA was significantly larger than the FNA in the TS group (36.6° ± 11.1° and 26.3° ± 10.9°, respectively: p < 0.001). However, no significant differences between the two were observed in the AS group (23.7° ± 10.1° and 22.7° ± 11.6°, respectively: p = 0.253). The preoperative planning of intentional increasing anteversion did not show high reproducibility with taper-wedge and anatomical stems. The anatomical stem was placed according to the femoral medullary canal regardless of preoperative planning with increased SA.
Collapse
Affiliation(s)
- Takehiro Kaneoka
- Department of Orthopaedic Surgery, Yamaguchi University Graduate School of Medicine, 1-1-1, Minami-Kogushi, Ube, 755-8505, Japan
| | - Takashi Imagama
- Department of Orthopaedic Surgery, Yamaguchi University Graduate School of Medicine, 1-1-1, Minami-Kogushi, Ube, 755-8505, Japan
| | - Tomoya Okazaki
- Department of Orthopaedic Surgery, Yamaguchi University Graduate School of Medicine, 1-1-1, Minami-Kogushi, Ube, 755-8505, Japan
| | - Yuta Matsuki
- Department of Orthopaedic Surgery, Yamaguchi University Graduate School of Medicine, 1-1-1, Minami-Kogushi, Ube, 755-8505, Japan
| | - Takehiro Kawakami
- Department of Orthopaedic Surgery, Yamaguchi University Graduate School of Medicine, 1-1-1, Minami-Kogushi, Ube, 755-8505, Japan
| | - Kazuhiro Yamazaki
- Department of Orthopaedic Surgery, Yamaguchi University Graduate School of Medicine, 1-1-1, Minami-Kogushi, Ube, 755-8505, Japan
| | - Takashi Sakai
- Department of Orthopaedic Surgery, Yamaguchi University Graduate School of Medicine, 1-1-1, Minami-Kogushi, Ube, 755-8505, Japan.
| |
Collapse
|
2
|
Hananouchi T, Satake S, Sakao K, Katsuda H, Shimada N, Dorthe EW, D’Lima DD. Determining the Relationship between Mechanical Properties and Quantitative Magnetic Resonance Imaging of Joint Soft Tissues Using Patient-Specific Templates. Bioengineering (Basel) 2023; 10:1050. [PMID: 37760152 PMCID: PMC10525776 DOI: 10.3390/bioengineering10091050] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/17/2023] [Revised: 08/11/2023] [Accepted: 09/05/2023] [Indexed: 09/29/2023] Open
Abstract
To determine whether the mechanical properties of joint soft tissues such as cartilage can be calculated from quantitative magnetic resonance imaging (MRI) data, we investigated whether the mechanical properties of articular cartilage and meniscus scheduled to be resected during arthroplasty are correlated with the T2 relaxation time on quantitative MRI at the same location. Six patients who had undergone knee arthroplasty and seven who had undergone hip arthroplasty were examined. For the knee joint, the articular cartilage and lateral meniscus of the distal lateral condyle of the femur and proximal lateral tibia were examined, while for the hip joint, the articular cartilage above the femoral head was studied. We investigated the relationship between T2 relaxation time by quantitative MRI and stiffness using a hand-made compression tester at 235 locations. The patient-individualized template technique was used to align the two measurement sites. The results showed a negative correlation (from -0.30 to -0.35) in the less severely damaged articular cartilage and meniscus. This indicates that tissue mechanical properties can be calculated from T2 relaxation time, suggesting that quantitative MRI is useful in determining when to start loading after interventional surgery on cartilage tissue and in managing the health of elderly patients.
Collapse
Affiliation(s)
- Takehito Hananouchi
- Biodesign Division, Department of Academia-Government-Industry Collaboration, Hiroshima University, Hiroshima, Hiroshima 734-8551, Japan
- Department of Mechanical Engineering, Faculty of Engineering, Osaka Sangyo University, Daito, Osaka 574-8530, Japan
- Department of Orthopaedic Surgery, Shimada Hospital, 100-1 Kashiyama, Habikino, Osaka 583-0875, Japan (K.S.)
- Shiley Center for Orthopaedic Research and Education at Scripps Clinic, La Jolla, CA 92037, USA
| | - Shinji Satake
- Department of Orthopaedic Surgery, Shimada Hospital, 100-1 Kashiyama, Habikino, Osaka 583-0875, Japan (K.S.)
| | - Kei Sakao
- Department of Orthopaedic Surgery, Shimada Hospital, 100-1 Kashiyama, Habikino, Osaka 583-0875, Japan (K.S.)
| | - Hiroshi Katsuda
- Department of Orthopaedic Surgery, Shimada Hospital, 100-1 Kashiyama, Habikino, Osaka 583-0875, Japan (K.S.)
| | - Nagakazu Shimada
- Department of Orthopaedic Surgery, Shimada Hospital, 100-1 Kashiyama, Habikino, Osaka 583-0875, Japan (K.S.)
| | - Erik W. Dorthe
- Shiley Center for Orthopaedic Research and Education at Scripps Clinic, La Jolla, CA 92037, USA
| | - Darryl D. D’Lima
- Shiley Center for Orthopaedic Research and Education at Scripps Clinic, La Jolla, CA 92037, USA
| |
Collapse
|
3
|
Matsuki Y, Imagama T, Tokushige A, Yamazaki K, Sakai T. Accuracy of cup placement using computed tomography-based navigation system in total hip arthroplasty through the direct anterior approach. J Orthop Sci 2023; 28:370-375. [PMID: 34823976 DOI: 10.1016/j.jos.2021.10.018] [Citation(s) in RCA: 2] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 07/26/2021] [Revised: 09/23/2021] [Accepted: 10/31/2021] [Indexed: 11/30/2022]
Abstract
BACKGROUND This study aimed to elucidate the accuracy of cup placement with the computed tomography (CT)-based navigation system (CTN) in the direct anterior approach (DAA)-total hip arthroplasty (THA) in the supine position compared with the mechanical cup alignment guide (MG) or the fluoroscopy (FS). METHODS A total of 171 hips of 156 patients undergone primary THA were classified into the following three groups (the MG group: 63 hips, the FS group: 58 hips, the CTN group: 50 hips). Comparing the preoperative planning with postoperative CT measurement by three-dimensional templating software, the accuracy of cup placement was investigated in the three groups. RESULTS There were significant differences in the mean absolute error of radiographic inclination (RI) between the MG group (4.4° ± 3.2°) and the CTN group (2.8° ± 2.5°) (p = 0.01). The mean absolute error of radiographic anteversion (RA) also showed significant differences between the CTN group (2.8° ± 1.9°) and the MG group (5.8° ± 4.7°) (p = 0.0001) or the FS group (4.8° ± 4.1°) (p = 0.02). Regarding the cup center position, the mean absolute error of vertical position from preoperative planning was the smallest in the CTN group (1.8 ± 1.4 mm) compared with those in other groups (MG: 3.3 ± 3.2 mm, p = 0.007, FS: 3.2 ± 3.0 mm, p = 0.017). CONCLUSION The CTN guarantees accurate cup placement in the DAA-THA in the supine position compared with the MG and FS groups.
Collapse
Affiliation(s)
- Yuta Matsuki
- Department of Orthopedic Surgery, Yamaguchi University Graduate School of Medicine, 1-1-1 Minamikogushi, Ube, Yamaguchi, 755-8505, Japan
| | - Takashi Imagama
- Department of Orthopedic Surgery, Yamaguchi University Graduate School of Medicine, 1-1-1 Minamikogushi, Ube, Yamaguchi, 755-8505, Japan.
| | - Atsunori Tokushige
- Department of Orthopedic Surgery, Ogori Daiichi General Hospital, 862-3 Ogori Shimogo, Yamaguchi City, Yamaguchi, 754-0002, Japan
| | - Kazuhiro Yamazaki
- Department of Orthopedic Surgery, Yamaguchi University Graduate School of Medicine, 1-1-1 Minamikogushi, Ube, Yamaguchi, 755-8505, Japan
| | - Takashi Sakai
- Department of Orthopedic Surgery, Yamaguchi University Graduate School of Medicine, 1-1-1 Minamikogushi, Ube, Yamaguchi, 755-8505, Japan
| |
Collapse
|
4
|
Image-Less THA Cup Navigation in Clinical Routine Setup: Individual Adjustments, Accuracy, Precision, and Robustness. MEDICINA (KAUNAS, LITHUANIA) 2022; 58:medicina58060832. [PMID: 35744095 PMCID: PMC9227241 DOI: 10.3390/medicina58060832] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 05/03/2022] [Revised: 06/08/2022] [Accepted: 06/12/2022] [Indexed: 12/13/2022]
Abstract
Background and Objectives: Even after the ‘death’ of Lewinnek’s safe zone, the orientation of the prosthetic cup in total hip arthroplasty is crucial for success. Accurate cup placement can be achieved with surgical navigation systems. The literature lacks study cohorts with large numbers of hips because postoperative computer tomography is required for the reproducible evaluation of the acetabular component position. To overcome this limitation, we used a validated software program, HipMatch, to accurately assess the cup orientation based on an anterior-posterior pelvic X-ray. The aim of this study were to (1) determine the intraoperative ‘individual adjustment’ of the cup positioning compared to the widely suggested target values of 40° of inclination and 15° of anteversion, and evaluate the (2) ‘accuracy’, (3) ‘precision’, and (4) robustness, regarding systematic errors, of an image-free navigation system in routine clinical use. Material and Methods: We performed a retrospective, accuracy study in a single surgeon case series of 367 navigated primary total hip arthroplasties (PiGalileoTM, Smith+Nephew) through an anterolateral approach performed between January 2011 and August 2018. The individual adjustments were defined as the differences between the target cup orientation (40° of inclination, 15° of anteversion) and the intraoperative registration with the navigation software. The accuracy was the difference between the intraoperative captured cup orientation and the actual postoperative cup orientation determined by HipMatch. The precision was analyzed by the standard deviation of the difference between the intraoperative registered and the actual cup orientation. The outliers were detected using the Tukey method. Results: Compared to the target value (40° inclination, 15° anteversion), the individual adjustments showed that the cups are impacted in higher inclination (mean 3.2° ± 1.6°, range, (−2)−18°) and higher anteversion (mean 5.0° ± 7.0°, range, (−15)−23°) (p < 0.001). The accuracy of the navigated cup placement was −1.7° ± 3.0°, ((−15)−11°) for inclination, and −4.9° ± 6.2° ((−28)−18°) for anteversion (p < 0.001). Precision of the system was higher for inclination (standard deviation SD 3.0°) compared to anteversion (SD 6.2°) (p < 0.001). We found no difference in the prevalence of outliers for inclination (1.9% (7 out of 367)) compared to anteversion (1.63% (6 out of 367), p = 0.78). The Bland-Altman analysis showed that the differences between the intraoperatively captured final position and the postoperatively determined actual position were spread evenly and randomly for inclination and anteversion. Conclusion: The evaluation of an image-less navigation system in this large study cohort provides accurate and reliable intraoperative feedback. The accuracy and the precision were inferior compared to CT-based navigation systems particularly regarding the anteversion. However the assessed values are certainly within a clinically acceptable range. This use of image-less navigation offers an additional tool to address challenging hip prothesis in the context of the hip−spine relationship to achieve adequate placement of the acetabular components with a minimum of outliers.
Collapse
|
5
|
Migliorini F, Pintore A, Eschweiler J, Oliva F, Hildebrand F, Maffulli N. Factors influencing the outcomes of minimally invasive total hip arthroplasty: a systematic review. J Orthop Surg Res 2022; 17:281. [PMID: 35585545 PMCID: PMC9118783 DOI: 10.1186/s13018-022-03168-4] [Citation(s) in RCA: 7] [Impact Index Per Article: 3.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 12/27/2021] [Accepted: 05/09/2022] [Indexed: 12/01/2022] Open
Abstract
Introduction The present systematic review investigated possible factors which may influence the surgical outcome of minimally invasive surgery for total hip arthroplasty (MIS THA). Methods In January 2022, the Embase, Google Scholar, PubMed, and Scopus databases were accessed. All the clinical trials investigating the clinical outcome of MIS THA were considered.
Results Data from 9486 procedures were collected. Older age was moderately associated with greater Visual Analogue Scale (VAS) (P = 0.02) and Western Ontario and McMaster Universities Osteoarthritis Index (WOMAC) (P = 0.009) at last follow-up, and shorter surgical duration (P = 0.01). Greater body mass index (BMI) at baseline was moderately associated with greater cup anteversion (P = 0.0009), Oxford Hip Score (OHS) at last follow-up (P = 0.04), longer surgical duration (P = 0.04), increased leg length discrepancy (P = 0.02), and greater rate of infection (P = 0.04). Greater VAS at baseline was weakly associated with greater VAS at last follow-up (P < 0.0001), total estimated blood lost (P = 0.01), and lower value of Harris Hip Score (HHS) (P = 0.0005). Greater OHS at baseline was associated with greater post-operative VAS (P = 0.01). Greater WOMAC at baseline was associated with lower cup anteversion (P = 0.009) and greater VAS (P = 0.02). Greater HHS at baseline was associated with shorter hospitalisation (P = 0.001). Conclusion Older age and greater BMI may represent negative prognostic factors for MIS THA. The clinical outcome is strongly influenced by the preoperative status of patients.
Collapse
Affiliation(s)
- Filippo Migliorini
- Department of Orthopaedic, Trauma, and Reconstructive Surgery, RWTH University Hospital, Pauwelsstraße 30, 52074, Aachen, Germany.
| | - Andrea Pintore
- Department of Medicine, Surgery and Dentistry, University of Salerno, Via S. Allende, 84081, Baronissi, SA, Italy
| | - Joerg Eschweiler
- Department of Orthopaedic, Trauma, and Reconstructive Surgery, RWTH University Hospital, Pauwelsstraße 30, 52074, Aachen, Germany
| | - Francesco Oliva
- Department of Medicine, Surgery and Dentistry, University of Salerno, Via S. Allende, 84081, Baronissi, SA, Italy
| | - Frank Hildebrand
- Department of Orthopaedic, Trauma, and Reconstructive Surgery, RWTH University Hospital, Pauwelsstraße 30, 52074, Aachen, Germany
| | - Nicola Maffulli
- Department of Medicine, Surgery and Dentistry, University of Salerno, Via S. Allende, 84081, Baronissi, SA, Italy.,School of Pharmacy and Bioengineering, Keele University School of Medicine, Thornburrow Drive, Stoke on Trent, England, UK.,Barts and the London School of Medicine and Dentistry, Centre for Sports and Exercise Medicine, Queen Mary University of London, Mile End Hospital, 275 Bancroft Road, London, E1 4DG, England, UK
| |
Collapse
|
6
|
Use of Surgical Approach Is Not Associated With Instability After Primary Total Hip Arthroplasty: A Meta-analysis Comparing Direct Anterior and Posterolateral Approaches. J Am Acad Orthop Surg 2021; 29:e1126-e1140. [PMID: 33315648 DOI: 10.5435/jaaos-d-20-00861] [Citation(s) in RCA: 15] [Impact Index Per Article: 5.0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 07/24/2020] [Accepted: 10/16/2020] [Indexed: 02/06/2023] Open
Abstract
INTRODUCTION Posterolateral approach (PA) has been historically associated with an increased risk of dislocation after primary total hip arthroplasty (THA), especially when compared with the direct anterior approach (DAA). However, current evidence is inconsistent regarding the risk of dislocation with either approach. The purpose of this study is to determine whether surgical approach influences joint stability. METHODS A systematic search in PubMed, MEDLINE, and Embase databases was performed. Randomized controlled trials (RCTs) and non-RCTs comparing DAA with PA in primary THA were included. Pooled effect measure of risk differences, relative risk and mean differences for postoperative dislocation, acetabular implant positioning, and leg length discrepancy were calculated. RESULTS Twenty-five studies (5 RCTs and 20 non-RCTs) of 7,172 THAs were assessed. There were no significant differences in dislocation rates between approaches (risk difference = -0.00, 95% confidence interval: -0.01 to 0.00; P = 0.92; I2 = 0%). Results were similar in the subgroup analysis of RCTs (P = 0.98), posterior soft-tissue repair (P = 0.50), and learning curve (P = 0.77). The acetabular implant was better positioned within the safe zone in the DAA group (relative risk = 1.17; 95% confidence interval: 1.03 to 1.33; P = 0.01), but no significant differences were found in cup inclination (P = 0.8), anteversion (P = 0.10), and leg length discrepancy (P = 0.54). CONCLUSION Dislocation rates after THA are not different between DAA and PA. Furthermore, no differences in the rate of dislocation were associated with cup positioning or surgical factors related with hip instability. Therefore, the surgical approach has little influence in prosthesis instability after primary THA. LEVEL OF EVIDENCE Level III.
Collapse
|
7
|
Awad ME, Farley BJ, Mostafa G, Saleh KJ. Direct anterior approach has short-term functional benefit and higher resource requirements compared with the posterior approach in primary total hip arthroplasty : a meta-analysis of functional outcomes and cost. Bone Joint J 2021; 103-B:1078-1087. [PMID: 34058867 DOI: 10.1302/0301-620x.103b6.bjj-2020-1271.r1] [Citation(s) in RCA: 17] [Impact Index Per Article: 5.7] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 11/05/2022]
Abstract
AIMS It has been suggested that the direct anterior approach (DAA) should be used for total hip arthroplasty (THA) instead of the posterior approach (PA) for better early functional outcomes. We conducted a value-based analysis of the functional outcome and associated perioperative costs, to determine which surgical approach gives the better short-term outcomes and lower costs. METHODS This meta-analysis was conducted according to the Preferred Reporting Items for Systematic Reviews and Meta-Analyses (PRISMA) protocol and the Cochrane Handbook. Several online databases were searched. Non-stratified and stratified meta-analyses were conducted to test the confounding biases in the studies which were included. The mean cost and probability were used to determine the added costs of perioperative services. RESULTS The DAA group had significantly longer operating times (p < 0.001), reduced length of hospital stay by a mean of 13.4 hours (95% confidence interval (CI) 9.12 to 18; p < 0.001), and greater blood loss (p = 0.030). The DAA group had significantly better functional outcome at three (p < 0.001) and six weeks (p = 0.006) postoperatively according to the Harris Hip Score (HHS). However, there was no significant difference between the groups for the HHS at six to eight weeks (p = 0.230), 12 weeks (p = 0.470), six months (p = 0.740), and one year (p = 0.610), the 12-Item Short Form Survey (SF-12) physical score at six weeks (p = 0.580) and one year (p = 0.360), SF-12 mental score at six weeks (p = 0.170) and one year (p = 0.960), and University of California and Los Angeles (UCLA) activity scale at 12 weeks (p = 0.250). The mean non-stratified and stratified difference in costs for the operating theatre time and blood transfusion were $587.57 (95% CI 263.83 to 1,010.29) to $887.04 (95% CI 574.20 to 1,298.88) and $248.38 (95% CI 1,003.40 to 1,539.90) to $1,162.41 (95% CI 645.78 to 7,441.30), respectively, more for the DAA group. However, the mean differences in costs for the time in hospital were $218.23 and $192.05, respectively, less for the DAA group. CONCLUSION The use of the DAA, rather than the PA, in THA has earlier benefits for function and pain. However, these are short-lasting, with no significant differences seen at later intervals. In addition the limited benefits were obtained with higher cumulative costs for DAA. Cite this article: Bone Joint J 2021;103-B(6):1078-1087.
Collapse
Affiliation(s)
- Mohamed E Awad
- Resident Research Partnership, Detroit, Michigan, USA.,NorthStar Anesthesia, Detroit Medical Center, Detroit, Michigan, USA.,School of Medicine, Wayne State University, Detroit, Michigan, USA
| | - Brendan J Farley
- Resident Research Partnership, Detroit, Michigan, USA.,College of Medicine, Central Michigan University, Mount Pleasant, Michigan, USA
| | - Gamal Mostafa
- School of Medicine, Wayne State University, Detroit, Michigan, USA.,Surgical Outcomes Research Institute, Detroit, Michigan, USA
| | - Khaled J Saleh
- Resident Research Partnership, Detroit, Michigan, USA.,Surgical Outcomes Research Institute, Detroit, Michigan, USA.,College of Osteopathic Medicine, Michigan State University, Detroit, Michigan, USA
| |
Collapse
|
8
|
Ramadanov N, Bueschges S, Liu K, Lazaru P, Marintschev I. Comparison of short-term outcomes between direct anterior approach (DAA) and SuperPATH in total hip replacement: a systematic review and network meta-analysis of randomized controlled trials. J Orthop Surg Res 2021; 16:324. [PMID: 34016136 PMCID: PMC8136223 DOI: 10.1186/s13018-021-02315-7] [Citation(s) in RCA: 10] [Impact Index Per Article: 3.3] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 12/28/2020] [Accepted: 02/18/2021] [Indexed: 12/22/2022] Open
Abstract
BACKGROUND Two minimally invasive approaches showed some advantages in outcomes compared to conventional approaches (CAs)-the direct anterior approach (DAA) and the supercapsular percutaneously assisted approach in THA (SuperPATH). To the best of our knowledge, DAA and SuperPATH have never been compared, neither in clinical studies, nor in a meta-analysis. To conduct a systematic review and network meta-analysis of randomized controlled trials comparing short-term outcomes of DAA and SuperPATH in total hip joint arthroplasty (THA). METHODS A systematic literature search up to May 2020 was performed to identify randomized controlled trials (RCTs) comparing SuperPATH with CAs and DAA with CAs in THA. We measured surgical, functional, and radiological outcomes. A network meta-analysis, using frequentist methods, was performed to assess treatment effects between DAA and SuperPATH. Information was borrowed from the above-mentioned RCTs, using the CA group as a common comparator. RESULTS A total of 16 RCTs involving 1392 patients met the inclusion criteria, three trials with a level I evidence, 13 trials with a level II evidence. The overall network meta-analysis showed that SuperPATH reduced operation time (fixed effect model: MD = 12.8, 95% CI 9.9 to 15.7), incision length (fixed effect model: MD = 4.3, 95% CI 4.0 to 4.5; random effect model: MD = 4.3, 95% CI 0.2 to 8.4), intraoperative blood loss (fixed effect model: MD = 58.6, 95% CI 40.4 to 76.8), and early pain intensity (VAS 1 day postoperatively with a fixed effect model: MD = 0.8, 95% CI 0.4 to 1.2). The two approaches did not differ in acetabular cup positioning angles and in functional outcome. CONCLUSIONS Our overall findings suggested that the short-term outcomes of THA through SuperPATH were superior to DAA. SuperPATH showed better results in decreasing operation time, incision length, intraoperative blood loss, and early pain intensity. DAA and SuperPATH were equal in functional outcome and acetabular cup positioning.
Collapse
Affiliation(s)
- Nikolai Ramadanov
- Clinic for Emergency Medicine, University Hospital Jena, Friedrich Schiller University, Am Klinikum 1, 07747, Jena, Germany.
| | - Simon Bueschges
- Faculty of Medicine, Department of Statistics, University of Salamanca, Calle Espejo 2, 37007, Salamanca, Spain
| | - Kuiliang Liu
- Department for Orthopaedics and Trauma Surgery, Siloah St. Trudpert Hospital, Wilferdinger Str. 67, 75179, Pforzheim, Germany
| | - Philip Lazaru
- Center for Surgery, Evangelical Hospital Ludwigsfelde-Teltow, Albert-Schweitzer-Str. 40-44, 14974, Ludwigsfelde, Germany
| | - Ivan Marintschev
- Department of Trauma, Hand and Reconstructive Surgery, University Hospital Jena, Friedrich Schiller University, Am Klinikum 1, 07747, Jena, Germany
| |
Collapse
|
9
|
Migliorini F, Trivellas A, Eschweiler J, Driessen A, Lessi F, Tingart M, Aretini P. Nerve palsy, dislocation and revision rate among the approaches for total hip arthroplasty: a Bayesian network meta-analysis. Musculoskelet Surg 2021; 105:1-15. [PMID: 32372300 DOI: 10.1007/s12306-020-00662-y] [Citation(s) in RCA: 5] [Impact Index Per Article: 1.7] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/18/2019] [Accepted: 04/18/2020] [Indexed: 06/11/2023]
Abstract
BACKGROUND Total hip arthroplasty (THA) is one of the most performed intervention in orthopaedics surgery. Currently, there is no unanimous approval concerning the best approach for THA in terms of nerve palsies, dislocations and further revisions. Hence, a Bayesian network meta-analysis was conducted. METHODS The present study was conducted according to the PRISMA extension statement for reporting of systematic reviews incorporating network meta-analyses of healthcare interventions. The literature search was performed in September 2019. The NMA was performed through the STATA Software/MP routine for Bayesian hierarchical random-effects model analysis. RESULTS Data from 10,675 THA were collected. The mean follow-up was 10 months. The anterior approach reported the lowest risk to incur a post-operative dislocation (overall inconsistency P = 0.99). The posterolateral approach reported the lowest risk to incur a nerve palsy (overall inconsistency P = 0.77). The funnel plot revealed a low risk of publication bias. The lateral approach was found to have the lowest risk of resulting in a revision surgery (overall inconsistency P = 0.90). CONCLUSION According to our network comparisons, the posterolateral approach for THA represent the favourable exposure with regards to nerve palsy, further dislocations and revision surgeries.
Collapse
Affiliation(s)
- F Migliorini
- Department of Orthopaedics, RWTH Aachen University Clinic, Pauwelsstraße 30, 52074, Aachen, Germany.
| | - A Trivellas
- Department of Orthopaedics, David Geffen School of Medicine at UCLA, Suite 755, Los Angeles, CA, 90095, USA
| | - J Eschweiler
- Department of Orthopaedics, RWTH Aachen University Clinic, Pauwelsstraße 30, 52074, Aachen, Germany
| | - A Driessen
- Department of Orthopaedics, RWTH Aachen University Clinic, Pauwelsstraße 30, 52074, Aachen, Germany
| | - F Lessi
- Fondazione Pisana Per La Scienza, Via Ferruccio Giovannini 13, 56017, Pise, Italy
| | - M Tingart
- Department of Orthopaedics, RWTH Aachen University Clinic, Pauwelsstraße 30, 52074, Aachen, Germany
| | - P Aretini
- Fondazione Pisana Per La Scienza, Via Ferruccio Giovannini 13, 56017, Pise, Italy
| |
Collapse
|
10
|
Implant positioning among the surgical approaches for total hip arthroplasty: a Bayesian network meta-analysis. Arch Orthop Trauma Surg 2020; 140:1115-1124. [PMID: 32361952 DOI: 10.1007/s00402-020-03448-w] [Citation(s) in RCA: 12] [Impact Index Per Article: 3.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 08/18/2019] [Indexed: 02/07/2023]
Abstract
INTRODUCTION Although there is anatomical individuality among patients, some standardized requirements for component orientation for total hip arthroplasty (THA) exist. To date, no study has compared implant positioning using a network meta-analysis (NMA). Hence, the purpose of this study was to perform a NMA comparing implant positioning among the various approaches for THA. METHODS This study was conducted according to the PRISMA extension statement for reporting of systematic reviews incorporating network meta-analyses of health care interventions. All randomized (RCT) and non-randomized (nRCT) clinical trials comparing two or more different approaches for THA were considered for inclusion. For the statistical analysis, the STATA Software/ MP, Version 14.1 (Stata Corporation, College Station, Texas, USA) was used. The NMA was performed through a Stata routine for Bayesian hierarchical random-effects model analysis. RESULTS We enrolled in the present study, a total of 4060 patients, with a mean of 17.84 ± 16.41 months follow-up. The patient baseline data were very homogeneous across the groups concerning age (P = 0.91), sex (P = 0.52), and BMI (P = 0.83). Concerning the cup anteversion, the anterolateral approach reported the value closest to the reference value. The test for overall inconsistency, however, was not statistically significant (P = 0.30). Concerning cup inclination, the lateral approach reported the value closest to the reference value. The test for overall inconsistency was statistically significant (P = 0.01). CONCLUSION The anterolateral approach for total hip arthroplasty detected the best femoral stem alignment and cup anteversion. Data concerning cup inclination detected no sufficient transitivity to draw consistent conclusions.
Collapse
|
11
|
Nakahara I, Kyo T, Kuroda Y, Miki H. Does difference in stem design affect accuracy of stem alignment in total hip arthroplasty with a CT-based navigation system? J Artif Organs 2020; 24:74-81. [PMID: 32710390 DOI: 10.1007/s10047-020-01196-7] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/31/2020] [Accepted: 07/15/2020] [Indexed: 10/23/2022]
Abstract
The efficacy of a computed tomography (CT)-based navigation system to accurately position the stem for intended alignment is unclear. In addition, the influence of stem design on the accuracy of insertion is unknown. We therefore retrospectively compared the accuracy and precision for the intended alignment of two different designs of femoral stem which were implanted with or without the navigation system. Forty-nine total hip arthroplasties (THAs) using a tapered wedge stem and 91 THAs using an anatomic stem were evaluated for the navigation group. Thirty-three THAs using the tapered wedge stem and 15 THAs using the anatomic stem were controls for the non-navigation group. Differences between postoperative measurement and preoperative planning were compared among the groups. In the navigation groups, accuracy (mean absolute difference) and precision (95% limits of agreement) of stem anteversion were 4.3° and ± 10.1° in the tapered wedge stem and 3.1° and ± 6.9° in the anatomic stem. In the non-navigation groups, these were 6.0° and ± 15.2° and 4.8° and ± 12.4°, respectively. The accuracy and precision in the navigation groups were significantly superior to those in the non-navigation group, and those in the anatomic stem group were significantly superior to those in the tapered wedge group. Using the CT-based navigation system, the accuracy and precision for intended stem anteversion were improved. When compared under guidance of navigation system, the accuracy and precision for intended stem anteversion in the anatomic stem were superior to those in the tapered wedge stem.
Collapse
Affiliation(s)
- Ichiro Nakahara
- Department of Orthopaedic Surgery, National Hospital Organization, Osaka National Hospital, 2-1-14 Hoenzaka, Chuo-ku, Osaka, 5400006, Japan.
| | - Takayuki Kyo
- Department of Orthopaedic Surgery, Bellland General Hospital, 500-3 Higashiyama, Naka-ku, Sakai-city, Osaka, 5998247, Japan
| | - Yasuo Kuroda
- Department of Orthopaedic Surgery, Suita Municipal Hospital, 5-7 Kishibeshinmachi, Suita-city, Osaka, 5648567, Japan
| | - Hidenobu Miki
- Department of Orthopaedic Surgery, National Hospital Organization, Osaka National Hospital, 2-1-14 Hoenzaka, Chuo-ku, Osaka, 5400006, Japan
| |
Collapse
|
12
|
Ezzibdeh RM, Barrett AA, Arora P, Amanatullah DF. Learning Curve for the Direct Superior Approach to Total Hip Arthroplasty. Orthopedics 2020; 43:e237-e243. [PMID: 32271934 DOI: 10.3928/01477447-20200404-05] [Citation(s) in RCA: 5] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 01/19/2019] [Accepted: 04/08/2019] [Indexed: 02/03/2023]
Abstract
Surgical learning curves are a representation of the number of cases required for a surgeon to reach a stable rate of outcomes and complications. In this study, the authors present the learning curve for the direct superior (DS) approach to total hip arthroplasty, which is a muscle-sparing modification to the mini-posterior technique. This was a retrospective analysis of the first 40 primary DS cases done by a single surgeon. These cases were divided into 2 groups of 20 and compared for intra- and postoperative complications, acetabular component positioning, and Harris Hip Score at 90 days after surgery. As a control, the first 20 primary mini-posterior cases were analyzed as the baseline performance of the surgeon and the DS approach. There was no statistically significant difference between the first and second sets of DS patients regarding Harris Hip Score, intraoperative complications, dislocations, estimated blood loss, length of hospital stay, and components positioned within the Lewinnek safe zone. The only statistically significant difference between the first and second sets of DS cases was a decrease in operating time (P<.001). This suggests that the learning curve is less than 20 patients. The results also indicate that the first 20 DS cases ambulated farther (P=.007) and had a shorter length of stay (P=.007), outperforming the mini-posterior approach. This study suggests that the DS learning curve is short for surgeons trained in the posterior approach. The data could be especially pertinent as 90-day results and safety are becoming increasingly important in evaluating performance for bundled-payment models. [Orthopedics. 2020;43(4):e237-e243.].
Collapse
|
13
|
Nakahara I, Kyo T, Kuroda Y, Miki H. Effect of improved navigation performance on the accuracy of implant placement in total hip arthroplasty with a CT-based navigation system. J Artif Organs 2018; 21:340-347. [PMID: 29611147 DOI: 10.1007/s10047-018-1041-6] [Citation(s) in RCA: 17] [Impact Index Per Article: 2.8] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/04/2017] [Accepted: 03/27/2018] [Indexed: 12/28/2022]
Abstract
A computed tomography (CT)-based navigation system is one of the support tools to place implant with appropriate alignment and position in total hip arthroplasty (THA). To determine whether the higher performance of the navigation would further improve the accuracy of implant placement in the clinical setting, we retrospectively compared the navigation accuracy of two different versions of a navigation system. The newer version of the navigation system had an upgraded optical sensor with superior positional accuracy. Navigation accuracy, defined as differences between postoperative measurements on CT images and intraoperative records on the navigation system, of 49 THAs performed with the newer version of the navigation system was compared with that of 49 THAs performed with the older version. With the newer version, the mean absolute accuracy (95% limits of agreement) of implant alignment was 1.2° (± 3.3°) for cup inclination, 1.0° (± 2.4°) for cup anteversion, 2.0° (± 4.9°) for stem anteversion, and 1.1° (± 2.4°) for stem valgus angle. The accuracy of the implant position was 1.5 mm (± 3.1 mm), 1.3 mm (± 3.0 mm), and 1.5 mm (± 3.1 mm) for cup x-, y-, and z-axes, respectively, 1.6 mm (± 3.2 mm), 1.4 mm (± 2.9 mm), and 1.5 mm (± 2.7 mm) for stem x-, y-, and z-axes, respectively, and 2.4 mm (± 4.5 mm) for leg length discrepancy. The values for the newer version were significantly more accurate with less variation compared to those of the older version. With upgraded navigation performance, more accurate implant placement was demonstrated in the clinical setting.
Collapse
Affiliation(s)
- Ichiro Nakahara
- Department of Orthopaedic Surgery, Osaka National Hospital, 2-1-14 oenzaka, Chuo-ku, Osaka, 5400006, Japan.
| | - Takayuki Kyo
- Department of Orthopaedic Surgery, Bellland General Hospital, 500-3 Higashiyama, Naka-ku, Sakai-city, Osaka, Japan
| | - Yasuo Kuroda
- Department of Orthopaedic Surgery, Osaka National Hospital, 2-1-14 oenzaka, Chuo-ku, Osaka, 5400006, Japan
| | - Hidenobu Miki
- Department of Orthopaedic Surgery, Osaka National Hospital, 2-1-14 oenzaka, Chuo-ku, Osaka, 5400006, Japan
| |
Collapse
|
14
|
Miller LE, Gondusky JS, Bhattacharyya S, Kamath AF, Boettner F, Wright J. Does Surgical Approach Affect Outcomes in Total Hip Arthroplasty Through 90 Days of Follow-Up? A Systematic Review With Meta-Analysis. J Arthroplasty 2018; 33:1296-1302. [PMID: 29195848 DOI: 10.1016/j.arth.2017.11.011] [Citation(s) in RCA: 111] [Impact Index Per Article: 18.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 10/09/2017] [Revised: 10/25/2017] [Accepted: 11/03/2017] [Indexed: 02/01/2023] Open
Abstract
BACKGROUND The choice between anterior approach (AA) and posterior approach (PA) in primary total hip arthroplasty (THA) is controversial. Previous reviews have predominantly relied on data from retrospective studies. METHODS This systematic review included prospective studies comparing postoperative outcomes through 90 days of AA vs PA in primary THA. Outcomes were pain severity, narcotic usage, hip function using Harris Hip Score, and complications. Random effects meta-analysis was performed for all outcomes. Efficacy data were reported as standardized mean difference (SMD) where values of 0.2, 0.5, 0.8, and 1.0 were defined as small, medium, large, and very large effect sizes, respectively. Complications were reported as the absolute risk difference (RD) where a positive value implied higher risk with AA and a lower value implied lower risk with AA. RESULTS A total of 13 prospective comparative studies (7 randomized) with patients treated with AA (n = 524) or PA (n = 520) were included. The AA was associated with lower pain severity (SMD = -0.37, P < .001), lower narcotic usage (SMD = -0.36, P = .002), and improved hip function (SMD = 0.31, P = .002) compared to PA. No differences between surgical approaches were observed for dislocation (RD = 0.2%, P = .87), fracture (RD = 0.2%, P = .87), hematoma (RD = 0%, P = .99), infection (RD = 0.2%, P = .85), thromboembolic event (RD = -0.9%, P = .42), or reoperation (RD = 1.3%, P = .26). Conclusions of this study were unchanged when subjected to sensitivity analyses. CONCLUSION In this systematic review and meta-analysis of prospective studies comparing postoperative outcomes through 90 days of AA vs PA in primary THA, patients treated with AA reported less pain, consumed fewer narcotics, and reported better hip function. No statistical differences in complication rates were detected between AA and PA. Ultimately, the choice of surgical approach in primary THA should consider preference and experience of the surgeon as well as preference and anatomy of the patient.
Collapse
Affiliation(s)
- Larry E Miller
- Miller Scientific Consulting, Inc, Asheville, North Carolina
| | | | | | - Atul F Kamath
- Penn Medicine, Department of Orthopedic Surgery, Leonard Davis Institute of Health Economics, Philadelphia, Pennsylvania
| | | | | |
Collapse
|
15
|
Yamada K, Endo H, Tetsunaga T, Miyake T, Sanki T, Ozaki T. Accuracy of Cup Positioning With the Computed Tomography-Based Two-dimensional to Three-Dimensional Matched Navigation System: A Prospective, Randomized Controlled Study. J Arthroplasty 2018; 33:136-143. [PMID: 28870743 DOI: 10.1016/j.arth.2017.08.001] [Citation(s) in RCA: 25] [Impact Index Per Article: 4.2] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 04/13/2017] [Revised: 07/28/2017] [Accepted: 08/01/2017] [Indexed: 02/01/2023] Open
Abstract
BACKGROUND The accuracy of various navigation systems used for total hip arthroplasty has been described, but no publications reported the accuracy of cup orientation in computed tomography (CT)-based 2D-3D (two-dimensional to three-dimensional) matched navigation. METHODS In a prospective, randomized controlled study, 80 hips including 44 with developmental dysplasia of the hips were divided into a CT-based 2D-3D matched navigation group (2D-3D group) and a paired-point matched navigation group (PPM group). The accuracy of cup orientation (absolute difference between the intraoperative record and the postoperative measurement) was compared between groups. Additionally, multiple logistic regression analysis was performed to evaluate patient factors affecting the accuracy of cup orientation in each navigation. RESULTS The accuracy of cup inclination was 2.5° ± 2.2° in the 2D-3D group and 4.6° ± 3.3° in the PPM group (P = .0016). The accuracy of cup anteversion was 2.3° ± 1.7° in the 2D-3D group and 4.4° ± 3.3° in the PPM group (P = .0009). In the PPM group, the presence of roof osteophytes decreased the accuracy of cup inclination (odds ratio 8.27, P = .0140) and the absolute value of pelvic tilt had a negative influence on the accuracy of cup anteversion (odds ratio 1.27, P = .0222). In the 2D-3D group, patient factors had no effect on the accuracy of cup orientation. CONCLUSION The accuracy of cup positioning in CT-based 2D-3D matched navigation was better than in paired-point matched navigation, and was not affected by patient factors. It is a useful system for even severely deformed pelvises such as developmental dysplasia of the hips.
Collapse
Affiliation(s)
- Kazuki Yamada
- Department of Orthopaedic Surgery, Okayama University Graduate School of Medicine, Dentistry, and Pharmaceutical Sciences, Okayama City, Okayama, Japan
| | - Hirosuke Endo
- Department of Orthopaedic Surgery, Okayama University Graduate School of Medicine, Dentistry, and Pharmaceutical Sciences, Okayama City, Okayama, Japan
| | - Tomonori Tetsunaga
- Department of Orthopaedic Surgery, Okayama University Graduate School of Medicine, Dentistry, and Pharmaceutical Sciences, Okayama City, Okayama, Japan
| | - Takamasa Miyake
- Department of Orthopaedic Surgery, Okayama University Graduate School of Medicine, Dentistry, and Pharmaceutical Sciences, Okayama City, Okayama, Japan
| | - Tomoaki Sanki
- Department of Orthopaedic Surgery, Okayama University Graduate School of Medicine, Dentistry, and Pharmaceutical Sciences, Okayama City, Okayama, Japan
| | - Toshifumi Ozaki
- Department of Orthopaedic Surgery, Okayama University Graduate School of Medicine, Dentistry, and Pharmaceutical Sciences, Okayama City, Okayama, Japan
| |
Collapse
|
16
|
Ogawa T, Takao M, Sakai T, Sugano N. Factors related to disagreement in implant size between preoperative CT-based planning and the actual implants used intraoperatively for total hip arthroplasty. Int J Comput Assist Radiol Surg 2017; 13:551-562. [DOI: 10.1007/s11548-017-1693-3] [Citation(s) in RCA: 9] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/04/2016] [Accepted: 12/06/2017] [Indexed: 12/20/2022]
|
17
|
Meermans G, Konan S, Das R, Volpin A, Haddad FS. The direct anterior approach in total hip arthroplasty: a systematic review of the literature. Bone Joint J 2017; 99-B:732-740. [PMID: 28566391 DOI: 10.1302/0301-620x.99b6.38053] [Citation(s) in RCA: 193] [Impact Index Per Article: 27.6] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 02/13/2016] [Accepted: 12/12/2016] [Indexed: 02/06/2023]
Abstract
AIMS The most effective surgical approach for total hip arthroplasty (THA) remains controversial. The direct anterior approach may be associated with a reduced risk of dislocation, faster recovery, reduced pain and fewer surgical complications. This systematic review aims to evaluate the current evidence for the use of this approach in THA. MATERIALS AND METHODS Following the Cochrane collaboration, an extensive literature search of PubMed, Medline, Embase and OvidSP was conducted. Randomised controlled trials, comparative studies, and cohort studies were included. Outcomes included the length of the incision, blood loss, operating time, length of stay, complications, and gait analysis. RESULTS A total of 42 studies met the inclusion criteria. Most were of medium to low quality. There was no difference between the direct anterior, anterolateral or posterior approaches with regards to length of stay and gait analysis. Papers comparing the length of the incision found similar lengths compared with the lateral approach, and conflicting results when comparing the direct anterior and posterior approaches. Most studies found the mean operating time to be significantly longer when the direct anterior approach was used, with a steep learning curve reported by many. Many authors used validated scores including the Harris hip score, and the Western Ontario and McMaster Universities Arthritis Index. These mean scores were better following the use of the direct anterior approach for the first six weeks post-operatively. Subsequently there was no difference between these scores and those for the posterior approach. CONCLUSION There is little evidence for improved kinematics or better long-term outcomes following the use of the direct anterior approach for THA. There is a steep learning curve with similar rates of complications, length of stay and outcomes. Well-designed, multi-centre, prospective randomised controlled trials are required to provide evidence as to whether the direct anterior approach is better than the lateral or posterior approaches when undertaking THA. Cite this article: Bone JointJ 2017;99-B:732-40.
Collapse
Affiliation(s)
- G Meermans
- Bravis Hospital, Boerhaaveplein 1, 4624VT Bergen op Zoom, The Netherlands
| | - S Konan
- University College London Hospitals, 235 Euston Road, London, NW1 2BU, UK
| | - R Das
- University College London Hospitals, 235 Euston Road, London, NW1 2BU, UK
| | - A Volpin
- University College London Hospitals, 235 Euston Road, London, NW1 2BU, UK
| | - F S Haddad
- NIHR University College London Hospitals Biomedical Research Centre, UK
| |
Collapse
|
18
|
The less invasive anterior approach for total hip arthroplasty: a comparison to other approaches and an evaluation of the learning curve - a systematic review. Hip Int 2017; 26:105-20. [PMID: 26951546 DOI: 10.5301/hipint.5000319] [Citation(s) in RCA: 29] [Impact Index Per Article: 4.1] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Accepted: 09/29/2015] [Indexed: 02/06/2023]
Abstract
There is still discussion about possible advantages and disadvantages of the less invasive anterior approach for total hip arthroplasty (THA). The purpose of our systematic review was to evaluate literature regarding the anterior approach in comparison to other approaches. Furthermore, we investigated if there is a description of a learning curve for the anterior approach.Data were obtained from EMBASE, Cochrane, PsycINFO, CINAHL, Web-of-Science, Scopus, Google scholar, and PubMed since their inception up to June 2015. 2 reviewers independently selected the studies and independently conducted the quality assessment. Because studies were considered heterogeneous regarding outcome measures, determinants studied, and methodological quality, we decided to perform a "best evidence synthesis". A total of 64 studies met the inclusion criteria.Strong evidence for no difference in component placement between the anterior approach and other approaches was found. Also, strong evidence for faster postoperative recovery and less need for assistive devices after the anterior approach were found. All other studied parameters only demonstrated conflicting evidence. Although the learning curve for the anterior approach is not yet clear, this learning curve should not to be neglected.In conclusion, the less invasive anterior approach provides benefits in the early postoperative period only, when compared to other approaches.
Collapse
|
19
|
Connolly KP, Kamath AF. Direct anterior total hip arthroplasty: Literature review of variations in surgical technique. World J Orthop 2016; 7:38-43. [PMID: 26807354 PMCID: PMC4716569 DOI: 10.5312/wjo.v7.i1.38] [Citation(s) in RCA: 29] [Impact Index Per Article: 3.6] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 05/27/2015] [Revised: 08/10/2015] [Accepted: 11/04/2015] [Indexed: 02/06/2023] Open
Abstract
The direct anterior approach to the hip has been suggested to have several advantages compared to previously popular approaches through its use of an intra-muscular and intra-nervous interval between the tensor fasciae latae and sartorius muscles. Recent increased interest in tissue-sparing and minimally-invasive arthroplasty has given rise to a sharp increase in the utilization of direct anterior total hip arthroplasty. A number of variations of the procedure have been described and several authors have published their experiences and feedback to successfully accomplishing this procedure. Additionally, improved understanding of relevant soft tissue constraints and anatomic variants has provided improved margin of safety for patients. The procedure may be performed using specially-designed instruments and a fracture table, however many authors have also described equally efficacious performance using a regular table and standard arthroplasty tools. The capacity to utilize fluoroscopy intra-operatively for component positioning is a valuable asset to the approach and can be of particular benefit for surgeons gaining familiarity. Proper management of patient and limb positioning are vital to reducing risk of intra-operative complications. An understanding of its limitations and challenges are also critical to safe employment. This review summarizes the key features of the direct anterior approach for total hip arthroplasty as an aid to improving the understanding of this important and effective method for modern hip replacement surgeons.
Collapse
|
20
|
Shandiz MA, MacKenzie JR, Hunt S, Anglin C. Accuracy of an adjustable patient-specific guide for acetabular alignment in hip replacement surgery (Optihip). Proc Inst Mech Eng H 2015; 228:876-89. [PMID: 25313024 DOI: 10.1177/0954411914548469] [Citation(s) in RCA: 8] [Impact Index Per Article: 0.9] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/17/2022]
Abstract
Implant malalignment in hip arthroplasty increases the risk of revision surgery due to problems such as hip instability, wear, and impingement. Traditional instrumentation lacks accuracy and does not individualize the goal. Computer-assisted surgery (CAS) and patient-specific solutions improve accuracy but add considerably to the cost, amongst other drawbacks. We developed an adjustable mechanical device, called Optihip, which is set to a patient-specific goal preoperatively and is independent of pelvis position intraoperatively. The purpose of the present study was to evaluate Optihip's accuracy ex vivo. Acetabular components were implanted into six cadaveric specimens, 12 hips, by two surgeons, with the device individually adjusted according to preoperative templating on computed tomography (CT) images relative to defined acetabular rim landmarks; options also exist for templating on single or biplanar X-rays. Intraoperatively, the device was positioned on the corresponding anatomical landmarks allowing the insertion of a guide pin, which then defined the desired orientation of the acetabular cup during impaction. Mean absolute difference between the preoperatively planned cup alignment and final acetabular cup orientation, measured from postoperative CT images, was 2.5±1.2° for inclination and 2.5±2.2° for version with maximum values of 4.7° and 6.8°, respectively. Compared with previous in vivo reports, Optihip guided the acetabular cup orientation more accurately than conventional hip arthroplasty, and comparably to CAS or patient-specific systems, while fitting into the normal surgical workflow. Although clinical testing is required to confirm these experimental results, the positive ex vivo accuracy suggests good potential for improving revision rates and patient functional outcome.
Collapse
Affiliation(s)
- Mohsen Akbari Shandiz
- Biomedical Engineering, University of Calgary, Calgary, AB, Canada McCaig Institute for Bone and Joint Health, University of Calgary, Calgary, AB, Canada
| | - James R MacKenzie
- McCaig Institute for Bone and Joint Health, University of Calgary, Calgary, AB, Canada Orthopaedic Surgery, University of Calgary, Calgary, AB, Canada
| | - Stephen Hunt
- McCaig Institute for Bone and Joint Health, University of Calgary, Calgary, AB, Canada Orthopaedic Surgery, University of Calgary, Calgary, AB, Canada
| | - Carolyn Anglin
- Biomedical Engineering, University of Calgary, Calgary, AB, Canada McCaig Institute for Bone and Joint Health, University of Calgary, Calgary, AB, Canada Department of Civil Engineering, University of Calgary, Calgary, AB, Canada
| |
Collapse
|
21
|
Higgins BT, Barlow DR, Heagerty NE, Lin TJ. Anterior vs. posterior approach for total hip arthroplasty, a systematic review and meta-analysis. J Arthroplasty 2015; 30:419-34. [PMID: 25453632 DOI: 10.1016/j.arth.2014.10.020] [Citation(s) in RCA: 237] [Impact Index Per Article: 26.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 08/26/2014] [Accepted: 10/13/2014] [Indexed: 02/06/2023] Open
Abstract
The objective of this study is to compare the clinical, radiographic and surgical outcomes among patients undergoing primary THA performed via the anterior versus posterior approach. We searched numerous sources and eventually included 17 studies, totaling 2302 participants. In terms of post-operative pain and function, the anterior approach was significantly favored in 4 studies at short-term follow-up. Pooled estimates showed a significant difference in favor of the anterior approach in terms of length of stay and dislocations. Current evidence comparing outcomes following anterior versus posterior THA does not demonstrate clear superiority of either approach. Until more rigorous, randomized evidence is available, we recommend choice of surgical approach for THA be based on patient characteristics, surgeon experience and surgeon and patient preference.
Collapse
Affiliation(s)
- Brendan T Higgins
- Department of Orthopaedic Surgery, Dartmouth Hitchcock Medical Center, Lebanon, New Hampshire; The Dartmouth Institute for Health Policy and Clinical Practice, Lebanon, New Hampshire
| | - Daniel R Barlow
- The Dartmouth Institute for Health Policy and Clinical Practice, Lebanon, New Hampshire; Geisel School of Medicine at Dartmouth, Hanover, New Hampshire
| | - Nathan E Heagerty
- The Dartmouth Institute for Health Policy and Clinical Practice, Lebanon, New Hampshire
| | - Tim J Lin
- Department of Orthopaedic Surgery, Dartmouth Hitchcock Medical Center, Lebanon, New Hampshire; The Dartmouth Institute for Health Policy and Clinical Practice, Lebanon, New Hampshire
| |
Collapse
|
22
|
Miki H, Kyo T, Sugano N. Anatomical hip range of motion after implantation during total hip arthroplasty with a large change in pelvic inclination. J Arthroplasty 2012; 27:1641-1650.e1. [PMID: 22521398 DOI: 10.1016/j.arth.2012.03.002] [Citation(s) in RCA: 34] [Impact Index Per Article: 2.8] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 02/19/2011] [Accepted: 03/01/2012] [Indexed: 02/01/2023] Open
Abstract
The supine functional pelvic plane is the recommended reference pelvic plane for acetabular cup planning in navigation-assisted total hip arthroplasty. However, it is unclear whether it can be used in patients with a large preoperative positional change in pelvic inclination (PC) from the supine to the standing position because it is unknown whether these patients have a different hip range of motion (ROM). We measured the anatomical hip ROM after implantation by computed tomography-based navigation in 91 patients and found it to be similar between those with a small PC (<10°) and those with a large PC (≥10°). There was no significant correlation between ROM and preoperative PC. The supine functional pelvic plane is adequate for cup planning whether the PC is small or large.
Collapse
Affiliation(s)
- Hidenobu Miki
- Department of Orthopedic Surgery, Osaka National Hospital, Osaka, Japan
| | | | | |
Collapse
|
23
|
Tailor-made Surgical Guide Reduces Incidence of Outliers of Cup Placement. Clin Orthop Relat Res 2010; 468:1088-95. [PMID: 19629605 PMCID: PMC2835612 DOI: 10.1007/s11999-009-0994-4] [Citation(s) in RCA: 34] [Impact Index Per Article: 2.4] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 02/09/2009] [Accepted: 07/07/2009] [Indexed: 01/31/2023]
Abstract
UNLABELLED Malalignment of the cup in total hip arthroplasty (THA) increases the risks of postoperative complications such as neck cup impingement, dislocation, and wear. We asked whether a tailor-made surgical guide based on CT images would reduce the incidence of outliers beyond 10 degrees from preoperatively planned alignment of the cup compared with those without the surgical guide. We prospectively followed 38 patients (38 hips, Group 1) having primary THA with the conventional technique and 31 patients (31 hips, Group 2) using the surgical guide. We designed the guide for Group 2 based on CT images and fixed it to the acetabular edge with a Kirschner wire to indicate the planned cup direction. Postoperative CT images showed the guide reduced the number of outliers compared with the conventional method (Group 1, 23.7%; Group 2, 0%). The surgical guide provided more reliable cup insertion compared with conventional techniques. LEVEL OF EVIDENCE Level II, therapeutic study. See the Guidelines for Authors for a complete description of levels of evidence.
Collapse
|
24
|
Hananouchi T, Saito M, Koyama T, Hagio K, Murase T, Sugano N, Yoshikawa H. Tailor-made surgical guide based on rapid prototyping technique for cup insertion in total hip arthroplasty. Int J Med Robot 2009; 5:164-9. [PMID: 19248055 DOI: 10.1002/rcs.243] [Citation(s) in RCA: 23] [Impact Index Per Article: 1.5] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/06/2022]
Abstract
BACKGROUND A surgical guide made by the rapid prototyping (RP) technique for cup insertion in total hip arthroplasty might be useful to avoid malalignment of the cup, which indicates postoperative complications. METHODS To address this research question, we applied a RP-based guide to 24 patients with their CT images. We designed it to fit onto the acetabular edge and to insert a Kirschner wire (K-wire) which indicated a planned cup direction. We intraoperatively placed it on the acetabular edge, inserted the K-wire through the guide on the superior acetabulum and implanted the cup while observing the alignment of the K-wire. We also recorded the additional time needed to use the guide. RESULTS The mean cup accuracy between planned and postoperative alignments was 2.8 degrees (SD = 2.1 degrees ) for abduction and 3.7 degrees (SD = 2.7 degrees ) for anteversion. The mean additional time was 3.5 (range 2-6) min. CONCLUSION We can use this guide with acceptable accuracy and without consuming an excessive amount of time.
Collapse
Affiliation(s)
- Takehito Hananouchi
- Department of Orthopaedic Surgery, Osaka University Graduate School of Medicine, Osaka, Japan.
| | | | | | | | | | | | | |
Collapse
|
25
|
Sugano N, Takao M, Sakai T, Nishii T, Miki H, Nakamura N. Comparison of mini-incision total hip arthroplasty through an anterior approach and a posterior approach using navigation. Orthop Clin North Am 2009; 40:365-70. [PMID: 19576404 DOI: 10.1016/j.ocl.2009.04.003] [Citation(s) in RCA: 31] [Impact Index Per Article: 2.1] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 02/06/2023]
Abstract
This study reports on differences in the use of minimally invasive surgery for total hip arthroplasty related to the direction of cup insertion against the operating table, intraoperative hip range of motion, stability, and a choice of cup liners for both a mini-incision posterior approach (MPA) and a mini-incision anterior approach (MAA) using Stryker Navigation's CT-Hip system. The MPA group consisted of 39 consecutive patients and the MAA group consisted of 33 consecutive patients. Clinically, there was no significant difference in the average Japanese Orthopedic Association hip score or the Oxford hip score preoperatively and at 6 months and 2 years follow-up. The intraoperative joint stability measurements showed no large difference between the two groups when malpositioning of the cup was eliminated.
Collapse
Affiliation(s)
- Nobuhiko Sugano
- Department of Orthopedic Surgery, Osaka University Graduate School of Medicine, Suita, Osaka 565-0871, Japan.
| | | | | | | | | | | |
Collapse
|