1
|
Seghier ML. 7 T and beyond: toward a synergy between fMRI-based presurgical mapping at ultrahigh magnetic fields, AI, and robotic neurosurgery. Eur Radiol Exp 2024; 8:73. [PMID: 38945979 PMCID: PMC11214939 DOI: 10.1186/s41747-024-00472-y] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/30/2024] [Accepted: 04/22/2024] [Indexed: 07/02/2024] Open
Abstract
Presurgical evaluation with functional magnetic resonance imaging (fMRI) can reduce postsurgical morbidity. Here, we discuss presurgical fMRI mapping at ultra-high magnetic fields (UHF), i.e., ≥ 7 T, in the light of the current growing interest in artificial intelligence (AI) and robot-assisted neurosurgery. The potential of submillimetre fMRI mapping can help better appreciate uncertainty on resection margins, though geometric distortions at UHF might lessen the accuracy of fMRI maps. A useful trade-off for UHF fMRI is to collect data with 1-mm isotropic resolution to ensure high sensitivity and subsequently a low risk of false negatives. Scanning at UHF might yield a revival interest in slow event-related fMRI, thereby offering a richer depiction of the dynamics of fMRI responses. The potential applications of AI concern denoising and artefact removal, generation of super-resolution fMRI maps, and accurate fusion or coregistration between anatomical and fMRI maps. The latter can benefit from the use of T1-weighted echo-planar imaging for better visualization of brain activations. Such AI-augmented fMRI maps would provide high-quality input data to robotic surgery systems, thereby improving the accuracy and reliability of robot-assisted neurosurgery. Ultimately, the advancement in fMRI at UHF would promote clinically useful synergies between fMRI, AI, and robotic neurosurgery.Relevance statement This review highlights the potential synergies between fMRI at UHF, AI, and robotic neurosurgery in improving the accuracy and reliability of fMRI-based presurgical mapping.Key points• Presurgical fMRI mapping at UHF improves spatial resolution and sensitivity.• Slow event-related designs offer a richer depiction of fMRI responses dynamics.• AI can support denoising, artefact removal, and generation of super-resolution fMRI maps.• AI-augmented fMRI maps can provide high-quality input data to robotic surgery systems.
Collapse
Affiliation(s)
- Mohamed L Seghier
- Department of Biomedical Engineering and Biotechnology, Khalifa University of Science and Technology, Abu Dhabi, UAE.
- Healtcare Engineering Innovation Center (HEIC), Khalifa University of Science and Technology, Abu Dhabi, UAE.
| |
Collapse
|
2
|
Cui Y, Zhou Y, Zhang H, Yuan Y, Wang J, Zhang Z. Application of Glasses-Free Augmented Reality Localization in Neurosurgery. World Neurosurg 2023; 180:e296-e301. [PMID: 37757949 DOI: 10.1016/j.wneu.2023.09.064] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/03/2023] [Revised: 09/15/2023] [Accepted: 09/16/2023] [Indexed: 09/29/2023]
Abstract
OBJECTIVE The accurate localization of intracranial lesions is critical in neurosurgery. Most surgeons locate the vast majority of neurosurgical sites through skull surface markers, combined with neuroimaging examination and marking lines. This project's primary purpose was to develop an augmented reality (AR) technology or tool that can be used for surgical positioning using the naked eye. METHODS Brain models were predesigned with intracranial lesions using computerized tomography scan, and Digital Imaging and Communications in Medicine data were segmented and modeled by 3D slicer software. The processed data were imported into a smartphone 3D viewing software application (Persp 3D) and were used by a Remebot surgical robot. The localization of intracranial lesions was performed, and the AR localization error was calculated compared with standard robot localization. RESULTS After mastering the AR localization registration method, surgeons achieved an average localization error of 1.39 ± 0.82 mm. CONCLUSIONS The error of AR positioning technology in surgical simulation tests based on brain modeling was millimeter level, which has verified the feasibility of clinical application. More efficient registration remains a need that should be addressed.
Collapse
Affiliation(s)
- Yahui Cui
- Department of Neurosurgery, Hangzhou Xixi Hospital Affiliated to Zhejiang University School of Medicine, Hangzhou, China
| | - Yupeng Zhou
- Department of Neurosurgery, Hangzhou Xixi Hospital Affiliated to Zhejiang University School of Medicine, Hangzhou, China
| | - Haipeng Zhang
- Department of Neurosurgery, Hangzhou Xixi Hospital Affiliated to Zhejiang University School of Medicine, Hangzhou, China
| | - Yuxiao Yuan
- Department of Radiology, Hangzhou Xixi Hospital Affiliated to Zhejiang University School of Medicine, Hangzhou, China
| | - Juan Wang
- Operating Room, Hangzhou Xixi Hospital Affiliated to Zhejiang University School of Medicine, Hangzhou, China
| | - Zuyong Zhang
- Department of Neurosurgery, Hangzhou Xixi Hospital Affiliated to Zhejiang University School of Medicine, Hangzhou, China.
| |
Collapse
|
3
|
Gorbachuk M, Machetanz K, Weinbrenner E, Grimm F, Wuttke TV, Wang S, Ethofer S, Tatagiba M, Rona S, Honegger J, Naros G. Robot-assisted stereoencephalography vs subdural electrodes in the evaluation of temporal lobe epilepsy. Epilepsia Open 2023; 8:888-897. [PMID: 37149851 PMCID: PMC10472365 DOI: 10.1002/epi4.12756] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/15/2022] [Accepted: 04/30/2023] [Indexed: 05/09/2023] Open
Abstract
OBJECTIVE Invasive video-electroencephalography (iVEEG) is the gold standard for evaluation of refractory temporal lobe epilepsy before second stage resective surgery (SSRS). Traditionally, the presumed seizure onset zone (SOZ) has been covered with subdural electrodes (SDE), a very invasive procedure prone to complications. Temporal stereoelectroencephalography (SEEG) with conventional frame-based stereotaxy is time-consuming and impeded by the geometry of the frame. The introduction of robotic assistance promised a simplification of temporal SEEG implantation. However, the efficacy of temporal SEEG in iVEEG remains unclear. The aim of this study was therefore to describe the efficiency and efficacy of SEEG in iVEEG of temporal lobe epilepsy. METHODS This retrospective study enrolled 60 consecutive patients with medically intractable epilepsy who underwent iVEEG of a potential temporal SOZ by SDE (n = 40) or SEEG (n = 20). Surgical time efficiency was analyzed by the skin-to-skin time (STS) and the total procedure time (TPT) and compared between groups (SDE vs SEEG). Surgical risk was depicted by the 90-day complication rate. Temporal SOZ were treated by SSRS. Favorable outcome (Engel°1) was assessed after 1 year of follow-up. RESULTS Robot-assisted SEEG significantly reduced the duration of surgery (STS and TPT) compared to SDE implantations. There was no significant difference in complication rates. Notably, all surgical revisions in this study were attributed to SDE. Unilateral temporal SOZ was detected in 34/60 cases. Of the 34 patients, 30 underwent second stage SSRS. Both SDE and SEEG had a good predictive value for the outcome of temporal SSRS with no significant group difference. SIGNIFICANCE Robot-assisted SEEG improves the accessibility of the temporal lobe for iVEEG by increasing surgical time efficiency and by simplifying trajectory selection without losing its predictive value for SSRS.
Collapse
Affiliation(s)
- Mykola Gorbachuk
- Neurosurgical Clinic, Department of Neurosurgery and NeurotechnologyEberhard Karls UniversityTuebingenGermany
| | - Kathrin Machetanz
- Neurosurgical Clinic, Department of Neurosurgery and NeurotechnologyEberhard Karls UniversityTuebingenGermany
| | - Eliane Weinbrenner
- Neurosurgical Clinic, Department of Neurosurgery and NeurotechnologyEberhard Karls UniversityTuebingenGermany
| | - Florian Grimm
- Neurosurgical Clinic, Department of Neurosurgery and NeurotechnologyEberhard Karls UniversityTuebingenGermany
| | - Thomas V. Wuttke
- Neurosurgical Clinic, Department of Neurosurgery and NeurotechnologyEberhard Karls UniversityTuebingenGermany
| | - Sophie Wang
- Neurosurgical Clinic, Department of Neurosurgery and NeurotechnologyEberhard Karls UniversityTuebingenGermany
| | - Silke Ethofer
- Neurosurgical Clinic, Department of Neurosurgery and NeurotechnologyEberhard Karls UniversityTuebingenGermany
| | - Marcos Tatagiba
- Neurosurgical Clinic, Department of Neurosurgery and NeurotechnologyEberhard Karls UniversityTuebingenGermany
| | - Sabine Rona
- Neurosurgical Clinic, Department of Neurosurgery and NeurotechnologyEberhard Karls UniversityTuebingenGermany
| | - Jürgen Honegger
- Neurosurgical Clinic, Department of Neurosurgery and NeurotechnologyEberhard Karls UniversityTuebingenGermany
| | - Georgios Naros
- Neurosurgical Clinic, Department of Neurosurgery and NeurotechnologyEberhard Karls UniversityTuebingenGermany
| |
Collapse
|
4
|
Kuris EO, Anderson GM, Osorio C, Basques B, Alsoof D, Daniels AH. Development of a Robotic Spine Surgery Program: Rationale, Strategy, Challenges, and Monitoring of Outcomes After Implementation. J Bone Joint Surg Am 2022; 104:e83. [PMID: 36197328 DOI: 10.2106/jbjs.22.00022] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 11/05/2022]
Abstract
Surgical robots were invented in the 1980s, and since then, robotic-assisted surgery has become commonplace. In the field of spine surgery, robotic assistance is utilized mainly to place pedicle screws, and multiple studies have demonstrated that robots can increase the accuracy of screw placement and reduce radiation exposure to the patient and the surgeon. However, this may be at the cost of longer operative times, complications, and the risk of errors in mapping the patient's anatomy.
Collapse
Affiliation(s)
- Eren O Kuris
- Department of Orthopedic Surgery, Warren Alpert Medical School, Brown University, Providence, Rhode Island
| | - George M Anderson
- Warren Alpert Medical School, Brown University, Providence, Rhode Island
| | - Camilo Osorio
- Department of Orthopedic Surgery, Warren Alpert Medical School, Brown University, Providence, Rhode Island
| | - Bryce Basques
- Department of Orthopedic Surgery, Warren Alpert Medical School, Brown University, Providence, Rhode Island
| | - Daniel Alsoof
- Department of Orthopedic Surgery, Warren Alpert Medical School, Brown University, Providence, Rhode Island
| | - Alan H Daniels
- Department of Orthopedic Surgery, Warren Alpert Medical School, Brown University, Providence, Rhode Island
| |
Collapse
|
5
|
Hu Y, Cai P, Zhang H, Adilijiang A, Peng J, Li Y, Che S, Lan F, Liu C. A Comparation Between Frame-Based and Robot-Assisted in Stereotactic Biopsy. Front Neurol 2022; 13:928070. [PMID: 35923834 PMCID: PMC9339900 DOI: 10.3389/fneur.2022.928070] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/25/2022] [Accepted: 06/22/2022] [Indexed: 11/13/2022] Open
Abstract
Introduction Frame-based stereotactic biopsy is well-established to play an essential role in neurosurgery. In recent years, different robotic devices have been introduced in neurosurgery centers. This study aimed to compare the SINO surgical robot-assisted frameless brain biopsy with standard frame-based stereotactic biopsy in terms of efficacy, accuracy and complications. Methods A retrospective analysis was performed on 151 consecutive patients who underwent stereotactic biopsy at Chongqing Sanbo Jiangling Hospital between August 2017 and December 2021. All patients were divided into the frame-based group (n = 47) and the SINO surgical robot-assisted group (n = 104). The data collected included clinical characteristics, diagnostic yield, operation times, accuracy, and postoperative complications. Results There was no significant difference in diagnostic yield between the frame-based group and the SINO surgical robot-assisted group (95.74 vs. 98.08%, p > 0.05). The mean operation time in the SINO surgical robot-assisted group was significantly shorter than in the frame-based group (29.36 ± 13.64 vs. 50.57 ± 41.08 min). The entry point error in the frame-based group was significantly higher than in the robot-assisted group [1.33 ± 0.40 mm (0.47–2.30) vs. 0.92 ± 0.27 mm (0.35–1.65), P < 0.001]. The target point error in the frame-based group was also significantly higher than in the robot-assisted group [1.63 ± 0.41 mm (0.74–2.65) vs. 1.10 ± 0.30 mm (0.69–2.03), P < 0.001]. Finally, there was no significant difference in postoperative complications between the two groups. Conclusion Robot-assisted brain biopsy becomes an increasingly mainstream tool in the neurosurgical procedure. The SINO surgical robot-assisted platform is as efficient, accurate and safe as standard frame-based stereotactic biopsy and provides a reasonable alternative to stereotactic biopsy in neurosurgery.
Collapse
Affiliation(s)
- Yue Hu
- Department of Neurosurgery, Sanbo Brain Hospital, Capital Medical University, Beijing, China
| | - Pu Cai
- Department of Neurosurgery, Chongqing Sanbo Jiangling Hospital, Chongqing, China
| | - Huawei Zhang
- Department of Neurosurgery, Sanbo Brain Hospital, Capital Medical University, Beijing, China
| | | | - Jun Peng
- Department of Neurosurgery, Chongqing Sanbo Jiangling Hospital, Chongqing, China
| | - Yun Li
- Department of Neurosurgery, Chongqing Sanbo Jiangling Hospital, Chongqing, China
| | - Shanli Che
- Department of Neurosurgery, Chongqing Sanbo Jiangling Hospital, Chongqing, China
| | - Fei Lan
- Department of Neurosurgery, Chongqing Sanbo Jiangling Hospital, Chongqing, China
| | - Changqing Liu
- Department of Neurosurgery, Sanbo Brain Hospital, Capital Medical University, Beijing, China
- Department of Neurosurgery, Chongqing Sanbo Jiangling Hospital, Chongqing, China
- Center of Epilepsy, Beijing Institute for Brain Disorders, Beijing, China
- *Correspondence: Changqing Liu
| |
Collapse
|
6
|
Machetanz K, Grimm F, Wang S, Schuhmann MU, Tatagiba M, Gharabaghi A, Naros G. Rediscovery of the transcerebellar approach: improving the risk-benefit ratio in robot-assisted brainstem biopsies. Neurosurg Focus 2022; 52:E12. [DOI: 10.3171/2021.10.focus21359] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/12/2021] [Accepted: 10/18/2021] [Indexed: 11/06/2022]
Abstract
OBJECTIVE
Conventional frame-based stereotaxy through a transfrontal approach (TFA) is the gold standard in brainstem biopsies. Because of the high surgical morbidity and limited impact on therapy, brainstem biopsies are controversial. The introduction of robot-assisted stereotaxy potentially improves the risk-benefit ratio by simplifying a transcerebellar approach (TCA). The aim of this single-center cohort study was to evaluate the risk-benefit ratio of transcerebellar brainstem biopsies performed by 2 different robotic systems. In addition to standard quality indicators, a special focus was set on trajectory selection for reducing surgical morbidity.
METHODS
This study included 25 pediatric (n = 7) and adult (n = 18) patients who underwent 26 robot-assisted biopsies via a TCA. The diagnostic yield, complication rate, trajectory characteristics (i.e., length, anatomical entry, and target-point location), and skin-to-skin (STS) time were evaluated. Transcerebellar and hypothetical transfrontal trajectories were reconstructed and transferred into a common MR space for further comparison with anatomical atlases.
RESULTS
Robot-assisted, transcerebellar biopsies demonstrated a high diagnostic yield (96.2%) while exerting no surgical mortality and no permanent morbidity in both pediatric and adult patients. Only 3.8% of cases involved a transient neurological deterioration. Transcerebellar trajectories had a length of 48.4 ± 7.3 mm using a wide stereotactic corridor via crus I or II of the cerebellum and the middle cerebellar peduncle. The mean STS time was 49.5 ± 23.7 minutes and differed significantly between the robotic systems (p = 0.017). The TFA was characterized by longer trajectories (107.4 ± 11.8 mm, p < 0.001) and affected multiple eloquent structures. Transfrontal target points were located significantly more medial (−3.4 ± 7.2 mm, p = 0.042) and anterior (−3.9 ± 8.4 mm, p = 0.048) in comparison with the transcerebellar trajectories.
CONCLUSIONS
Robot-assisted, transcerebellar stereotaxy can improve the risk-benefit ratio of brainstem biopsies by avoiding the restrictions of a TFA and conventional frame-based stereotaxy. Profound registration and anatomical-functional trajectory selection were essential to reduce mortality and morbidity.
Collapse
Affiliation(s)
- Kathrin Machetanz
- Neurosurgical Clinic, Department of Neurosurgery and Neurotechnology, Eberhard Karls University, Tuebingen
- Institute for Neuromodulation and Neurotechnology, Department of Neurosurgery and Neurotechnology, Eberhard Karls University, Tuebingen, Germany
| | - Florian Grimm
- Neurosurgical Clinic, Department of Neurosurgery and Neurotechnology, Eberhard Karls University, Tuebingen
- Institute for Neuromodulation and Neurotechnology, Department of Neurosurgery and Neurotechnology, Eberhard Karls University, Tuebingen, Germany
| | - Sophie Wang
- Neurosurgical Clinic, Department of Neurosurgery and Neurotechnology, Eberhard Karls University, Tuebingen
| | - Martin U. Schuhmann
- Neurosurgical Clinic, Department of Neurosurgery and Neurotechnology, Eberhard Karls University, Tuebingen
| | - Marcos Tatagiba
- Neurosurgical Clinic, Department of Neurosurgery and Neurotechnology, Eberhard Karls University, Tuebingen
| | - Alireza Gharabaghi
- Neurosurgical Clinic, Department of Neurosurgery and Neurotechnology, Eberhard Karls University, Tuebingen
- Institute for Neuromodulation and Neurotechnology, Department of Neurosurgery and Neurotechnology, Eberhard Karls University, Tuebingen, Germany
| | - Georgios Naros
- Neurosurgical Clinic, Department of Neurosurgery and Neurotechnology, Eberhard Karls University, Tuebingen
- Institute for Neuromodulation and Neurotechnology, Department of Neurosurgery and Neurotechnology, Eberhard Karls University, Tuebingen, Germany
| |
Collapse
|
7
|
Udayakumaran S, Krishnadas A, Subash P. Robot-assisted frontofacial correction in very young children with craniofacial dysostosis syndromes: a technical note and early functional outcome. Neurosurg Focus 2022; 52:E16. [PMID: 34973669 DOI: 10.3171/2021.10.focus21515] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/29/2021] [Accepted: 10/19/2021] [Indexed: 11/06/2022]
Abstract
OBJECTIVE In this study, the authors aimed to 1) retrospectively analyze the early functional outcomes in a cohort of very young children with craniofacial dysostoses who underwent robot-assisted frontofacial advancement (RAFFA) or robot-assisted midface distraction (RAMD), and 2) analyze the utility of robotic assistance in improving the accuracy and safety of performing transfacial pin insertion for RAFFA or RAMD. METHODS A retrospective analysis of a cohort of 18 children (age range 1-42 months at presentation), who underwent RAFFA or RAMD from February 2015 to February 2021 in the craniofacial unit at Amrita Institute of Medical Sciences and Research Centre in Kochi, India, was performed. Inclusion criteria were patients who had undergone RAFFA in a single stage or RAMD where the cranial vault had been addressed earlier, had been addressed on follow-up, or had not been addressed and had follow-up of at least 6 months. RESULTS Overall, 18 children with syndromic craniosynostosis underwent LeFort level III midface distraction, with or without RAFFA, from February 2015 to February 2021 at a single center in India. The patients' ages ranged from 6 to 47 months at the time of the procedure. All patients had significant obstructive sleep apnea (OSA), significant ocular issues, and disturbed sleep as determined by the authors' preoperative protocol. Clinically significant intracranial pressure issues were present in 17 patients. None of the patients had injury due to the transfacial pin trajectory such as globe injury, damage to the tooth buds, or the loss of purchase during the active distraction phase. The mean distraction achieved was 23 mm (range 18-30 mm) (n = 16/18). Of the 18 patients, 10 (56%) had an excellent outcome and 6 (33%) had a satisfactory outcome. In all cases, the degree of OSA had significantly reduced after surgery. Eye closure improved in all patients, and complete closure was seen in 11 patients. On follow-up, the functional gain remained in 14 of 16 patients at the final follow-up visit. The distraction results were stable during the follow-up period (mean 36 months [range 6-72 months]). CONCLUSIONS The early RAFFA and RAMD protocols investigated in this study gave a significant functional advantage in very young patients with craniofacial dysostoses. The results have demonstrated the accuracy and safety of robotic assistance in performing transfacial pin insertion for RAFFA or RAMD.
Collapse
Affiliation(s)
- Suhas Udayakumaran
- 1Division of Paediatric Neurosurgery and Craniofacial Surgery, Department of Neurosurgery, Amrita Institute of Medical Sciences and Research Centre, Amrita Viswa Vidyapeetham, Kochi, Kerala; and
| | - Arjun Krishnadas
- 2Division of Craniomaxillofacial Surgery, Amrita Institute of Medical Sciences and Research Centre, Amrita Viswa Vidyapeetham, Kochi, Kerala, India
| | - Pramod Subash
- 2Division of Craniomaxillofacial Surgery, Amrita Institute of Medical Sciences and Research Centre, Amrita Viswa Vidyapeetham, Kochi, Kerala, India
| |
Collapse
|