1
|
Ma X, Zhou Y, Xin M, Yuan H, Chao D, Liu F, Jia X, Sun P, Wang C, Lu G, Wallace G. A Mg Battery-Integrated Bioelectronic Patch Provides Efficient Electrochemical Stimulations for Wound Healing. ADVANCED MATERIALS (DEERFIELD BEACH, FLA.) 2024; 36:e2410205. [PMID: 39361260 DOI: 10.1002/adma.202410205] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 07/15/2024] [Revised: 09/04/2024] [Indexed: 11/29/2024]
Abstract
Bioelectronic patches hold promise for patient-comfort wound healing providing simplified clinical operation. Currently, they face paramount challenges in establishing long-term effective electronic interfaces with targeted cells and tissues due to the inconsistent energy output and high bio interface impedance. Here a new electrochemical stimulation technology is reported, using a simple wound patch, which integrates the efficient generation and delivery of stimulation. This is realized by employing a hydrogel bioelectronic interface as an active component in an integrated power source (i.e., Mg battery). The Mg battery enhances fibroblast functions (proliferation, migration, and growth factor secretion) and regulates macrophage phenotype (promoting regenerative polarization and down-regulating pro-inflammatory cytokines), by providing an electric field and the ability to control the cellular microenvironment through chemical release. This bioelectronic patch shows an effective and accelerated wound closure by guiding epithelial migration, mediating immune response, and promoting vasculogenesis. This new electrochemical-mediated therapy may provide a new avenue for user-friendly wound management as well as a platform for fundamental insights into cell stimulation.
Collapse
Affiliation(s)
- Xuenan Ma
- State Key Laboratory of Integrated Optoelectronics, College of Electronic Science and Engineering, Jilin University, Changchun, 130012, China
| | - Yan Zhou
- State Key Laboratory of Integrated Optoelectronics, College of Electronic Science and Engineering, Jilin University, Changchun, 130012, China
| | - Meiying Xin
- Jilin Provincial Key Laboratory of Pediatric Neurology, Department of Pediatric Neurology, The First Hospital of Jilin University, Changchun, 130021, China
| | - Hongming Yuan
- College of Animal Sciences, Jilin University, Changchun, 130062, China
| | - Danming Chao
- College of Chemistry, Jilin University, Changchun, 130012, China
| | - Fangmeng Liu
- State Key Laboratory of Integrated Optoelectronics, College of Electronic Science and Engineering, Jilin University, Changchun, 130012, China
- International Center of Future Science, Jilin University, Changchun, 130012, China
| | - Xiaoteng Jia
- State Key Laboratory of Integrated Optoelectronics, College of Electronic Science and Engineering, Jilin University, Changchun, 130012, China
| | - Peng Sun
- State Key Laboratory of Integrated Optoelectronics, College of Electronic Science and Engineering, Jilin University, Changchun, 130012, China
- International Center of Future Science, Jilin University, Changchun, 130012, China
| | - Caiyun Wang
- Intelligent Polymer Research Institute, Faculty of Engineering and Information Sciences, University of Wollongong, North Wollongong, NSW, 2500, Australia
| | - Geyu Lu
- State Key Laboratory of Integrated Optoelectronics, College of Electronic Science and Engineering, Jilin University, Changchun, 130012, China
- International Center of Future Science, Jilin University, Changchun, 130012, China
| | - Gordon Wallace
- Intelligent Polymer Research Institute, Faculty of Engineering and Information Sciences, University of Wollongong, North Wollongong, NSW, 2500, Australia
| |
Collapse
|
2
|
Rivkin B, Akbar F, Otto M, Beyer L, Paul B, Kosiba K, Gustmann T, Hufenbach J, Medina-Sánchez M. Remotely Controlled Electrochemical Degradation of Metallic Implants. SMALL (WEINHEIM AN DER BERGSTRASSE, GERMANY) 2024; 20:e2307742. [PMID: 38326101 DOI: 10.1002/smll.202307742] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 09/05/2023] [Revised: 01/22/2024] [Indexed: 02/09/2024]
Abstract
Biodegradable medical implants promise to benefit patients by eliminating risks and discomfort associated with permanent implantation or surgical removal. The time until full resorption is largely determined by the implant's material composition, geometric design, and surface properties. Implants with a fixed residence time, however, cannot account for the needs of individual patients, thereby imposing limits on personalization. Here, an active Fe-based implant system is reported whose biodegradation is controlled remotely and in situ. This is achieved by incorporating a galvanic cell within the implant. An external and wireless signal is used to activate the on-board electronic circuit that controls the corrosion current between the implant body and an integrated counter electrode. This configuration leads to the accelerated degradation of the implant and allows to harvest electrochemical energy that is naturally released by corrosion. In this study, the electrochemical properties of the Fe-30Mn-1C/Pt galvanic cell model system is first investigated and high-resolution X-ray microcomputed tomography is used to evaluate the galvanic degradation of stent structures. Subsequently, a centimeter-sized active implant prototype is assembled with conventional electronic components and the remotely controlled corrosion is tested in vitro. Furthermore, strategies toward the miniaturization and full biodegradability of this system are presented.
Collapse
Affiliation(s)
- Boris Rivkin
- Leibniz Institute for Solid State and Materials Research (IFW), 01069, Dresden, Germany
| | - Farzin Akbar
- Leibniz Institute for Solid State and Materials Research (IFW), 01069, Dresden, Germany
| | - Martin Otto
- Leibniz Institute for Solid State and Materials Research (IFW), 01069, Dresden, Germany
- Institute of Materials Science, Technische Universität Bergakademie Freiberg, 09599, Freiberg, Germany
| | - Lukas Beyer
- Leibniz Institute for Solid State and Materials Research (IFW), 01069, Dresden, Germany
- Institute of Materials Science, Technische Universität Bergakademie Freiberg, 09599, Freiberg, Germany
| | - Birgit Paul
- Leibniz Institute for Solid State and Materials Research (IFW), 01069, Dresden, Germany
| | - Konrad Kosiba
- Leibniz Institute for Solid State and Materials Research (IFW), 01069, Dresden, Germany
| | - Tobias Gustmann
- Leibniz Institute for Solid State and Materials Research (IFW), 01069, Dresden, Germany
| | - Julia Hufenbach
- Leibniz Institute for Solid State and Materials Research (IFW), 01069, Dresden, Germany
- Institute of Materials Science, Technische Universität Bergakademie Freiberg, 09599, Freiberg, Germany
| | - Mariana Medina-Sánchez
- Leibniz Institute for Solid State and Materials Research (IFW), 01069, Dresden, Germany
- Center for Molecular Bioengineering (B CUBE), Chair of Micro- and Nano Systems, Technische Universität Dresden, 01307, Dresden, Germany
- CIC nanoGUNE-BRTA, Donostia-San Sebastián, 20018, Spain
- Ikerbasque, Basque Foundation for Science, Bilbao, 48013, Spain
| |
Collapse
|
3
|
Yan B, Zhao Y, Peng H. Tissue-Matchable and Implantable Batteries Toward Biomedical Applications. SMALL METHODS 2023; 7:e2300501. [PMID: 37469190 DOI: 10.1002/smtd.202300501] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 04/14/2023] [Revised: 06/30/2023] [Indexed: 07/21/2023]
Abstract
Implantable electronic devices can realize real-time and reliable health monitoring, diagnosis, and treatment of human body, which are expected to overcome important bottlenecks in the biomedical field. However, the commonly used energy supply devices for them are implantable batteries based on conventional rigid device design with toxic components, which both mechanically and biologically mismatch soft biological tissues. Therefore, the development of highly soft, safe, and implantable tissue-matchable flexible batteries is of great significance and urgency for implantable bioelectronics. In this work, the recent advances of tissue-matchable and implantable flexible batteries are overviewed, focusing on the design strategies of electrodes/batteries and their biomedical applications. The mechanical flexibility, biocompatibility, and electrochemical performance in vitro and in vivo of these flexible electrodes/batteries are then discussed. Finally, perspectives are provided on the current challenges and possible directions of this field in the future.
Collapse
Affiliation(s)
- Bing Yan
- Institute of Flexible Electronics and Research and Development Institute of Northwestern Polytechnical University in Shenzhen, Northwestern Polytechnical University, Xi'an, 710072, China
| | - Yang Zhao
- Institute of Flexible Electronics and Research and Development Institute of Northwestern Polytechnical University in Shenzhen, Northwestern Polytechnical University, Xi'an, 710072, China
- State Key Laboratory of Organic Electronics and Information Displays and Institute of Advanced Materials (IAM), Nanjing University of Posts and Telecommunications, Nanjing, 210023, China
| | - Huisheng Peng
- State Key Laboratory of Molecular Engineering of Polymers, Department of Macromolecular Science and Laboratory of Advanced Materials, Fudan University, Shanghai, 200438, China
| |
Collapse
|
4
|
Lu K, Zhu XY, Li Y, Gu N. Progress in the preparation of Prussian blue-based nanomaterials for biomedical applications. J Mater Chem B 2023. [PMID: 36748242 DOI: 10.1039/d2tb02617a] [Citation(s) in RCA: 7] [Impact Index Per Article: 3.5] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/26/2023]
Abstract
Prussian blue (PB) is composed of the coordination network of Fe2+-CN-Fe3+ mixed valence state as a classic metal complex, which includes a C atom and Fe2+ (low spin), N atom and Fe3+ (high spin). PB and its analogues (PBA) have excellent biosafety, good magnetic properties, outstanding photothermal properties and the ability to mimic enzymatic behaviors due to their stable structure, tunable size, controllable morphology, abundant modification methods and excellent physicochemical properties. They have received increasing research interest and have shown promising applications in the biomedical field. Here, progress in the preparation of PB-based nanomaterials for biomedical applications is summarized and discussed. The preparation strategies, traditional synthesis and emerging preparation methods of PB are summarized systematically in this review. The design and preparation of PBA, PB(PBA)-based hollow structures and PB(PBA)-based composites are also included. While introducing the preparation status, some PB-based nanomaterials that have performed well in specific biomedical fields are emphasized. More importantly, the key factors and future development of PB for the clinical translation as multifunctional nanomaterials are also discussed. This review provides a reference for the design and biomedical application of PB-based nanomaterials.
Collapse
Affiliation(s)
- Kun Lu
- State Key Laboratory of Bioelectronics, Jiangsu Key Laboratory for Biomaterials and Devices, School of Biological Science and Medical Engineering, Southeast University, Nanjing 210009, P. R. China.
| | - Xiao-Yang Zhu
- State Key Laboratory of Bioelectronics, Jiangsu Key Laboratory for Biomaterials and Devices, School of Biological Science and Medical Engineering, Southeast University, Nanjing 210009, P. R. China.
| | - Yan Li
- State Key Laboratory of Bioelectronics, Jiangsu Key Laboratory for Biomaterials and Devices, School of Biological Science and Medical Engineering, Southeast University, Nanjing 210009, P. R. China.
| | - Ning Gu
- State Key Laboratory of Bioelectronics, Jiangsu Key Laboratory for Biomaterials and Devices, School of Biological Science and Medical Engineering, Southeast University, Nanjing 210009, P. R. China. .,Medical School, Nanjing University, Nanjing 210093, P. R. China
| |
Collapse
|