Han X, Yu J, Yang X, Chen C, Zhou H, Qiu C, Cao Y, Zhang T, Peng M, Zhu G, Ni D, Zhang Y, Liu N. Artificial intelligence assistance for fetal development: evaluation of an automated software for biometry measurements in the mid-trimester. BMC Pregnancy Childbirth 2024; 24:158. [PMID: 38395822 PMCID: PMC10885506 DOI: 10.1186/s12884-024-06336-y] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/31/2023] [Accepted: 02/08/2024] [Indexed: 02/25/2024] Open
Abstract
BACKGROUND This study presents CUPID, an advanced automated measurement software based on Artificial Intelligence (AI), designed to evaluate nine fetal biometric parameters in the mid-trimester. Our primary objective was to assess and compare the CUPID performance of experienced senior and junior radiologists. MATERIALS AND METHODS This prospective cross-sectional study was conducted at Shenzhen University General Hospital between September 2022 and June 2023, and focused on mid-trimester fetuses. All ultrasound images of the six standard planes, that enabled the evaluation of nine biometric measurements, were included to compare the performance of CUPID through subjective and objective assessments. RESULTS There were 642 fetuses with a mean (±SD) age of 22 ± 2.82 weeks at enrollment. In the subjective quality assessment, out of 642 images representing nine biometric measurements, 617-635 images (90.65-96.11%) of CUPID caliper placements were determined to be accurately placed and did not require any adjustments. Whereas, for the junior category, 447-691 images (69.63-92.06%) were determined to be accurately placed and did not require any adjustments. In the objective measurement indicators, across all nine biometric parameters and estimated fetal weight (EFW), the intra-class correlation coefficients (ICC) (0.843-0.990) and Pearson correlation coefficients (PCC) (0.765-0.978) between the senior radiologist and CUPID reflected good reliability compared with the ICC (0.306-0.937) and PCC (0.566-0.947) between the senior and junior radiologists. Additionally, the mean absolute error (MAE), percentage error (PE), and average error in days of gestation were lower between the senior and CUPID compared to the difference between the senior and junior radiologists. The specific differences are as follows: MAE (0.36-2.53 mm, 14.67 g) compared to (0.64- 8.13 mm, 38.05 g), PE (0.94-9.38%) compared to (1.58-16.04%), and average error in days (3.99-7.92 days) compared to (4.35-11.06 days). In the time-consuming task, CUPID only takes 0.05-0.07 s to measure nine biometric parameters, while senior and junior radiologists require 4.79-11.68 s and 4.95-13.44 s, respectively. CONCLUSIONS CUPID has proven to be highly accurate and efficient software for automatically measuring fetal biometry, gestational age, and fetal weight, providing a precise and fast tool for assessing fetal growth and development.
Collapse
Affiliation(s)
- Xuesong Han
- Department of Ultrasonography, Shenzhen University General Hospital, Shenzhen, Guangdong, China
| | - Junxuan Yu
- National-Regional Key Technology Engineering Laboratory for Medical Ultrasound, School of Biomedical Engineering, Shenzhen University Medical School, Shenzhen University, Shenzhen, Guangdong, China
- Medical Ultrasound Image Computing (MUSIC) Lab, Shenzhen University, Shenzhen, Guangdong, China
- Marshall Laboratory of Biomedical Engineering, Shenzhen University, Shenzhen, Guangdong, China
| | - Xin Yang
- National-Regional Key Technology Engineering Laboratory for Medical Ultrasound, School of Biomedical Engineering, Shenzhen University Medical School, Shenzhen University, Shenzhen, Guangdong, China
- Medical Ultrasound Image Computing (MUSIC) Lab, Shenzhen University, Shenzhen, Guangdong, China
- Marshall Laboratory of Biomedical Engineering, Shenzhen University, Shenzhen, Guangdong, China
| | - Chaoyu Chen
- National-Regional Key Technology Engineering Laboratory for Medical Ultrasound, School of Biomedical Engineering, Shenzhen University Medical School, Shenzhen University, Shenzhen, Guangdong, China
- Medical Ultrasound Image Computing (MUSIC) Lab, Shenzhen University, Shenzhen, Guangdong, China
- Marshall Laboratory of Biomedical Engineering, Shenzhen University, Shenzhen, Guangdong, China
| | - Han Zhou
- National-Regional Key Technology Engineering Laboratory for Medical Ultrasound, School of Biomedical Engineering, Shenzhen University Medical School, Shenzhen University, Shenzhen, Guangdong, China
- Medical Ultrasound Image Computing (MUSIC) Lab, Shenzhen University, Shenzhen, Guangdong, China
- Marshall Laboratory of Biomedical Engineering, Shenzhen University, Shenzhen, Guangdong, China
| | - Chuangxin Qiu
- National-Regional Key Technology Engineering Laboratory for Medical Ultrasound, School of Biomedical Engineering, Shenzhen University Medical School, Shenzhen University, Shenzhen, Guangdong, China
- Medical Ultrasound Image Computing (MUSIC) Lab, Shenzhen University, Shenzhen, Guangdong, China
- Marshall Laboratory of Biomedical Engineering, Shenzhen University, Shenzhen, Guangdong, China
| | - Yan Cao
- Shenzhen RayShape Medical Technology Co., Ltd, Shenzhen, Guangdong, China
| | | | | | - Guiyao Zhu
- Department of Ultrasonography, Shenzhen University General Hospital, Shenzhen, Guangdong, China
| | - Dong Ni
- National-Regional Key Technology Engineering Laboratory for Medical Ultrasound, School of Biomedical Engineering, Shenzhen University Medical School, Shenzhen University, Shenzhen, Guangdong, China
- Medical Ultrasound Image Computing (MUSIC) Lab, Shenzhen University, Shenzhen, Guangdong, China
- Marshall Laboratory of Biomedical Engineering, Shenzhen University, Shenzhen, Guangdong, China
| | - Yuanji Zhang
- National-Regional Key Technology Engineering Laboratory for Medical Ultrasound, School of Biomedical Engineering, Shenzhen University Medical School, Shenzhen University, Shenzhen, Guangdong, China.
- Medical Ultrasound Image Computing (MUSIC) Lab, Shenzhen University, Shenzhen, Guangdong, China.
- Marshall Laboratory of Biomedical Engineering, Shenzhen University, Shenzhen, Guangdong, China.
| | - Nana Liu
- Department of Ultrasonography, Shenzhen University General Hospital, Shenzhen, Guangdong, China.
| |
Collapse
|