1
|
Gao Q, Rohr K. A Global Method for Non-Rigid Registration of Cell Nuclei in Live Cell Time-Lapse Images. IEEE TRANSACTIONS ON MEDICAL IMAGING 2019; 38:2259-2270. [PMID: 30835217 DOI: 10.1109/tmi.2019.2901918] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 06/09/2023]
Abstract
Non-rigid registration of cell nuclei in time-lapse microscopy images can be achieved through estimating the deformation fields using optical flow methods. In contrast to local optical flow models employed in the existing non-rigid registration methods, we introduce approaches based on a global optical flow model. Our registration model consists of a data fidelity term and a regularization term. We compared different regularizers for the deformation fields and found that a convex quadratic function is more suitable than non-convex ones. To improve the robustness, we propose an adaptive weighting scheme based on the statistics of the noise in fluorescence microscopy images as well as a combined local-global scheme. Moreover, we extend the global method by exploiting high-order image features. The best suitable high-order features are determined through learning two generative image models, namely, fields of experts and convolutional Gaussian restricted Boltzmann machine, whose model formulations are both consistent with the assumption of high-order feature constancy in the registration model. Using multiple data sets of real 2D and 3D live cell microscopy image sequences as well as synthetic image data, we demonstrate that our proposed approach outperforms the previous methods in terms of both registration accuracy and computational efficiency.
Collapse
|
2
|
Qiao M, Wang Y, Berendsen FF, van der Geest RJ, Tao Q. Fully automated segmentation of the left atrium, pulmonary veins, and left atrial appendage from magnetic resonance angiography by joint-atlas-optimization. Med Phys 2019; 46:2074-2084. [PMID: 30861147 PMCID: PMC6849806 DOI: 10.1002/mp.13475] [Citation(s) in RCA: 5] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/30/2018] [Revised: 01/17/2019] [Accepted: 01/18/2019] [Indexed: 11/09/2022] Open
Abstract
PURPOSE Atrial fibrillation (AF) originating from the left atrium (LA) and pulmonary veins (PVs) is the most prevalent cardiac electrophysiological disorder. Accurate segmentation and quantification of the LA chamber, PVs, and left atrial appendage (LAA) provides clinically important references for treatment of AF patients. The purpose of this work is to realize objective segmentation of the LA chamber, PVs, and LAA in an accurate and fully automated manner. METHODS In this work, we proposed a new approach, named joint-atlas-optimization, to segment the LA chamber, PVs, and LAA from magnetic resonance angiography (MRA) images. We formulated the segmentation as a single registration problem between the given image and all N atlas images, instead of N separate registration between the given image and an individual atlas image. Level sets was applied to refine the atlas-based segmentation. Using the publically available LA benchmark database, we compared the proposed joint-atlas-optimization approach to the conventional pairwise atlas approach and evaluated the segmentation performance in terms of Dice index and surface-to-surface (S2S) distance to the manual ground truth. RESULTS The proposed joint-atlas-optimization method showed systemically improved accuracy and robustness over the pairwise atlas approach. The Dice of LA segmentation using joint-atlas-optimization was 0.93 ± 0.04, compared to 0.91 ± 0.04 by the pairwise approach (P < 0.05). The mean S2S distance was 1.52 ± 0.58 mm, compared to 1.83 ± 0.75 mm (P < 0.05). In particular, it produced significantly improved segmentation accuracy of the LAA and PVs, the small distant part in LA geometry that is intrinsically difficult to segment using the conventional pairwise approach. The Dice of PVs segmentation was 0.69 ± 0.16, compared to 0.49 ± 0.15 (P < 0.001). The Dice of LAA segmentation was 0.91 ± 0.03, compared to 0.88 ± 0.05 (P < 0.01). CONCLUSION The proposed joint-atlas optimization method can segment the complex LA geometry in a fully automated manner. Compared to the conventional atlas approach in a pairwise manner, our method improves the performance on small distal parts of LA, for example, PVs and LAA, the geometrical and quantitative assessment of which is clinically interesting.
Collapse
Affiliation(s)
- Menyun Qiao
- Biomedical Engineering Center, Fudan University, Shanghai, 200433, China
| | - Yuanyuan Wang
- Biomedical Engineering Center, Fudan University, Shanghai, 200433, China
| | - Floris F Berendsen
- Department of Radiology, Leiden University Medical Center, Leiden, 2300 RC, The Netherlands
| | - Rob J van der Geest
- Department of Radiology, Leiden University Medical Center, Leiden, 2300 RC, The Netherlands
| | - Qian Tao
- Department of Radiology, Leiden University Medical Center, Leiden, 2300 RC, The Netherlands
| |
Collapse
|
3
|
Tektonidis M, Rohr K. Diffeomorphic Multi-Frame Non-Rigid Registration of Cell Nuclei in 2D and 3D Live Cell Images. IEEE TRANSACTIONS ON IMAGE PROCESSING : A PUBLICATION OF THE IEEE SIGNAL PROCESSING SOCIETY 2017; 26:1405-1417. [PMID: 28092560 DOI: 10.1109/tip.2017.2653360] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 06/06/2023]
Abstract
To gain a better understanding of cellular and molecular processes, it is important to quantitatively analyze the motion of subcellular particles in live cell microscopy image sequences. Since, generally, the subcellular particles move and cell nuclei move as well as deform, it is important to decouple the movement of particles from that of the cell nuclei using non-rigid registration methods. We have developed a diffeomorphic multi-frame approach for non-rigid registration of cell nuclei in 2D and 3D live cell fluorescence microscopy images. Our non-rigid registration approach is based on local optic flow estimation, exploits information from multiple consecutive image frames, and determines diffeomorphic transformations in the log-domain, which allows efficient computation of the inverse transformations. To register single images of an image sequence to a reference image, we use a temporally weighted mean image, which is constructed based on inverse transformations and multiple consecutive frames. Using multiple consecutive frames improves the registration accuracy compared to pairwise registration, and using a temporally weighted mean image significantly reduces the computation time compared with previous work. In addition, we use a flow boundary preserving method for regularization of computed deformation vector fields, which prevents from over-smoothing compared to standard Gaussian filtering. Our approach has been successfully applied to 2D and 3D synthetic as well as real live cell microscopy image sequences, and an experimental comparison with non-rigid pairwise, multi-frame, and temporal groupwise registration has been carried out.
Collapse
|
4
|
Johansson A, Balter J, Feng M, Cao Y. An Overdetermined System of Transform Equations in Support of Robust DCE-MRI Registration With Outlier Rejection. ACTA ACUST UNITED AC 2016; 2:188-196. [PMID: 28367502 PMCID: PMC5373730 DOI: 10.18383/j.tom.2016.00145] [Citation(s) in RCA: 5] [Impact Index Per Article: 0.6] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/28/2022]
Abstract
Quantitative hepatic perfusion parameters derived by fitting dynamic contrast-enhanced (DCE) magnetic resonance imaging (MRI) of liver to a pharmacokinetic model are prone to errors if the dynamic images are not corrected for respiratory motion by image registration. The contrast-induced intensity variations in pre- and postcontrast phases pose challenges for the accuracy of image registration. We propose an overdetermined system of transformation equations between the image volumes in the DCE-MRI series to achieve robust alignment. In this method, we register each volume to every other volume. From the transforms produced by all pairwise registrations, we constructed an overdetermined system of transform equations that was solved robustly by minimizing the L1/2-norm of the residuals. This method was evaluated on a set of 100 liver DCE-MRI examinations from 35 patients by examining the area under spikes appearing in the voxel time–intensity curves. The robust alignment procedure significantly reduced the area under intensity spikes compared with unregistered volumes (P < .001) and volumes registered to a single reference phase (P < .001). Our registration procedure provides a larger number of reliable time–intensity curve samples. The additional reliable samples in the precontrast baseline are important for calculating the postcontrast signal enhancement and thereby for converting intensity to contrast concentration. On the intensity ramp, retained samples help to better describe the uptake dynamics, providing a better foundation for parameter estimation. The presented method also simplifies the analysis of data sets with many patients by eliminating the need for manual intervention during registration.
Collapse
Affiliation(s)
- Adam Johansson
- Department of Radiation Oncology, University of Michigan, Ann Arbor, Michigan
| | - James Balter
- Department of Radiation Oncology, University of Michigan, Ann Arbor, Michigan; Department of Biomedical Engineering, University of Michigan, Ann Arbor, Michigan
| | - Mary Feng
- Department of Radiation Oncology, University of Michigan, Ann Arbor, Michigan
| | - Yue Cao
- Department of Radiation Oncology, University of Michigan, Ann Arbor, Michigan; Department of Radiology, University of Michigan, Ann Arbor, Michigan; Department of Biomedical Engineering, University of Michigan, Ann Arbor, Michigan
| |
Collapse
|
5
|
Porras AR, Alessandrini M, De Craene M, Duchateau N, Sitges M, Bijnens BH, Delingette H, Sermesant M, D'hooge J, Frangi AF, Piella G. Improved myocardial motion estimation combining tissue Doppler and B-mode echocardiographic images. IEEE TRANSACTIONS ON MEDICAL IMAGING 2014; 33:2098-2106. [PMID: 24956282 DOI: 10.1109/tmi.2014.2331392] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 06/03/2023]
Abstract
We propose a technique for myocardial motion estimation based on image registration using both B-mode echocardiographic images and tissue Doppler sequences acquired interleaved. The velocity field is modeled continuously using B-splines and the spatiotemporal transform is constrained to be diffeomorphic. Images before scan conversion are used to improve the accuracy of the estimation. The similarity measure includes a model of the speckle pattern distribution of B-mode images. It also penalizes the disagreement between tissue Doppler velocities and the estimated velocity field. Registration accuracy is evaluated and compared to other alternatives using a realistic synthetic dataset, obtaining mean displacement errors of about 1 mm. Finally, the method is demonstrated on data acquired from six volunteers, both at rest and during exercise. Robustness is tested against low image quality and fast heart rates during exercise. Results show that our method provides a robust motion estimate in these situations.
Collapse
|
6
|
Zhang Z, Ashraf M, Sahn DJ, Song X. Temporally diffeomorphic cardiac motion estimation from three-dimensional echocardiography by minimization of intensity consistency error. Med Phys 2014; 41:052902. [PMID: 24784402 PMCID: PMC4000394 DOI: 10.1118/1.4867864] [Citation(s) in RCA: 7] [Impact Index Per Article: 0.6] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/08/2013] [Revised: 02/14/2014] [Accepted: 02/22/2014] [Indexed: 11/07/2022] Open
Abstract
PURPOSE Quantitative analysis of cardiac motion is important for evaluation of heart function. Three dimensional (3D) echocardiography is among the most frequently used imaging modalities for motion estimation because it is convenient, real-time, low-cost, and nonionizing. However, motion estimation from 3D echocardiographic sequences is still a challenging problem due to low image quality and image corruption by noise and artifacts. METHODS The authors have developed a temporally diffeomorphic motion estimation approach in which the velocity field instead of the displacement field was optimized. The optimal velocity field optimizes a novel similarity function, which we call the intensity consistency error, defined as multiple consecutive frames evolving to each time point. The optimization problem is solved by using the steepest descent method. RESULTS Experiments with simulated datasets, images of anex vivo rabbit phantom, images of in vivo open-chest pig hearts, and healthy human images were used to validate the authors' method. Simulated and real cardiac sequences tests showed that results in the authors' method are more accurate than other competing temporal diffeomorphic methods. Tests with sonomicrometry showed that the tracked crystal positions have good agreement with ground truth and the authors' method has higher accuracy than the temporal diffeomorphic free-form deformation (TDFFD) method. Validation with an open-access human cardiac dataset showed that the authors' method has smaller feature tracking errors than both TDFFD and frame-to-frame methods. CONCLUSIONS The authors proposed a diffeomorphic motion estimation method with temporal smoothness by constraining the velocity field to have maximum local intensity consistency within multiple consecutive frames. The estimated motion using the authors' method has good temporal consistency and is more accurate than other temporally diffeomorphic motion estimation methods.
Collapse
Affiliation(s)
- Zhijun Zhang
- Department of Biomedical Engineering, Oregon Health and Science University (OHSU), 3181 Southwest Sam Jackson Park Road, Portland, Oregon 97239
| | - Muhammad Ashraf
- Department of Pediatric Cardiology, Oregon Health and Science University, 3181 Southwest Sam Jackson Park Road, Portland, Oregon 97239
| | - David J Sahn
- Department of Biomedical Engineering, Oregon Health and Science University (OHSU), 3181 Southwest Sam Jackson Park Road, Portland, Oregon 97239 and Department of Pediatric Cardiology, Oregon Health and Science University, 3181 Southwest Sam Jackson Park Road, Portland, Oregon 97239
| | - Xubo Song
- Department of Biomedical Engineering, Oregon Health and Science University (OHSU), 3181 Southwest Sam Jackson Park Road, Portland, Oregon 97239
| |
Collapse
|
7
|
Wu G, Wang Q, Lian J, Shen D. Estimating the 4D respiratory lung motion by spatiotemporal registration and super-resolution image reconstruction. Med Phys 2013; 40:031710. [PMID: 23464305 DOI: 10.1118/1.4790689] [Citation(s) in RCA: 19] [Impact Index Per Article: 1.6] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/25/2022] Open
Abstract
PURPOSE One of the main challenges in lung cancer radiation therapy is how to reduce the treatment margin but accommodate the geometric uncertainty of moving tumor. 4D-CT is able to provide the full range of motion information for the lung and tumor. However, accurate estimation of lung motion with respect to the respiratory phase is difficult due to various challenges in image registration, e.g., motion artifacts and large interslice thickness in 4D-CT. Meanwhile, the temporal coherence across respiration phases is usually not guaranteed in the conventional registration methods which consider each phase image in 4D-CT independently. To address these challenges, the authors present a unified approach to estimate the respiratory lung motion with two iterative steps. METHODS First, the authors propose a novel spatiotemporal registration algorithm to align all phase images of 4D-CT (in low-resolution) to a high-resolution group-mean image in the common space. The temporal coherence of registration is maintained by a set of temporal fibers that delineate temporal correspondences across different respiratory phases. Second, a super-resolution technique is utilized to build the high-resolution group-mean image with more anatomical details than any individual phase image, thus largely alleviating the registration uncertainty especially in correspondence detection. In particular, the authors use the concept of sparse representation to keep the group-mean image as sharp as possible. RESULTS The performance of our 4D motion estimation method has been extensively evaluated on both the simulated datasets and real lung 4D-CT datasets. In all experiments, our method achieves more accurate and consistent results in lung motion estimation than all other state-of-the-art approaches under comparison. CONCLUSIONS The authors have proposed a novel spatiotemporal registration method to estimate the lung motion in 4D-CT. Promising results have been obtained, which indicates the high applicability of our method in clinical lung cancer radiation therapy.
Collapse
Affiliation(s)
- Guorong Wu
- Department of Radiology and BRIC, University of North Carolina at Chapel Hill, Chapel Hill, North Carolina 27599, USA.
| | | | | | | |
Collapse
|
8
|
Wachinger C, Navab N. Simultaneous registration of multiple images: similarity metrics and efficient optimization. IEEE TRANSACTIONS ON PATTERN ANALYSIS AND MACHINE INTELLIGENCE 2013; 35:1221-1233. [PMID: 23520261 DOI: 10.1109/tpami.2012.196] [Citation(s) in RCA: 17] [Impact Index Per Article: 1.4] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 06/01/2023]
Abstract
We address the alignment of a group of images with simultaneous registration. Therefore, we provide further insights into a recently introduced framework for multivariate similarity measures, referred to as accumulated pair-wise estimates (APE), and derive efficient optimization methods for it. More specifically, we show a strict mathematical deduction of APE from a maximum-likelihood framework and establish a connection to the congealing framework. This is only possible after an extension of the congealing framework with neighborhood information. Moreover, we address the increased computational complexity of simultaneous registration by deriving efficient gradient-based optimization strategies for APE: Gauss-Newton and the efficient second-order minimization (ESM). We present next to SSD the usage of intrinsically nonsquared similarity measures in this least squares optimization framework. The fundamental assumption of ESM, the approximation of the perfectly aligned moving image through the fixed image, limits its application to monomodal registration. We therefore incorporate recently proposed structural representations of images which allow us to perform multimodal registration with ESM. Finally, we evaluate the performance of the optimization strategies with respect to the similarity measures, leading to very good results for ESM. The extension to multimodal registration is in this context very interesting because it offers further possibilities for evaluations, due to publicly available datasets with ground-truth alignment.
Collapse
Affiliation(s)
- Christian Wachinger
- Massachusetts Institute of Technology, and Department of Neurology, Harvard Medical School, Cambridge, MA 02139, USA.
| | | |
Collapse
|
9
|
De Craene M, Piella G, Camara O, Duchateau N, Silva E, Doltra A, D’hooge J, Brugada J, Sitges M, Frangi AF. Temporal diffeomorphic free-form deformation: Application to motion and strain estimation from 3D echocardiography. Med Image Anal 2012; 16:427-50. [PMID: 22137545 DOI: 10.1016/j.media.2011.10.006] [Citation(s) in RCA: 80] [Impact Index Per Article: 6.2] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/16/2011] [Revised: 10/25/2011] [Accepted: 10/25/2011] [Indexed: 11/27/2022]
|