1
|
Yang SY, Sencadas V, You SS, Jia NZX, Srinivasan SS, Huang HW, Ahmed AE, Liang JY, Traverso G. Powering Implantable and Ingestible Electronics. ADVANCED FUNCTIONAL MATERIALS 2021; 31:2009289. [PMID: 34720792 PMCID: PMC8553224 DOI: 10.1002/adfm.202009289] [Citation(s) in RCA: 29] [Impact Index Per Article: 9.7] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 10/30/2020] [Indexed: 05/28/2023]
Abstract
Implantable and ingestible biomedical electronic devices can be useful tools for detecting physiological and pathophysiological signals, and providing treatments that cannot be done externally. However, one major challenge in the development of these devices is the limited lifetime of their power sources. The state-of-the-art of powering technologies for implantable and ingestible electronics is reviewed here. The structure and power requirements of implantable and ingestible biomedical electronics are described to guide the development of powering technologies. These powering technologies include novel batteries that can be used as both power sources and for energy storage, devices that can harvest energy from the human body, and devices that can receive and operate with energy transferred from exogenous sources. Furthermore, potential sources of mechanical, chemical, and electromagnetic energy present around common target locations of implantable and ingestible electronics are thoroughly analyzed; energy harvesting and transfer methods befitting each energy source are also discussed. Developing power sources that are safe, compact, and have high volumetric energy densities is essential for realizing long-term in-body biomedical electronics and for enabling a new era of personalized healthcare.
Collapse
Affiliation(s)
- So-Yoon Yang
- Department of Electrical Engineering and Computer Science, Massachusetts Institute of Technology, Cambridge, MA 02139, USA; Koch Institute for Integrative Cancer Research, Massachusetts Institute of Technology, Cambridge, MA 02139, USA; Department of Mechanical Engineering, Massachusetts Institute of Technology, Cambridge, MA 02139, USA
| | - Vitor Sencadas
- Koch Institute for Integrative Cancer Research, Massachusetts Institute of Technology, Cambridge, MA 02139, USA; School of Mechanical, Materials & Mechatronics Engineering, University of Wollongong, Wollongong, NSW 2522, Australia
| | - Siheng Sean You
- Koch Institute for Integrative Cancer Research, Massachusetts Institute of Technology, Cambridge, MA 02139, USA; Department of Mechanical Engineering, Massachusetts Institute of Technology, Cambridge, MA 02139, USA; Division of Gastroenterology, Hepatology and Endoscopy, Department of Medicine, Brigham and Women's Hospital, Harvard Medical School, Boston, MA 02115, USA
| | - Neil Zi-Xun Jia
- Koch Institute for Integrative Cancer Research, Massachusetts Institute of Technology, Cambridge, MA 02139, USA
| | - Shriya Sruthi Srinivasan
- Koch Institute for Integrative Cancer Research, Massachusetts Institute of Technology, Cambridge, MA 02139, USA; Department of Mechanical Engineering, Massachusetts Institute of Technology, Cambridge, MA 02139, USA; Division of Gastroenterology, Hepatology and Endoscopy, Department of Medicine, Brigham and Women's Hospital, Harvard Medical School, Boston, MA 02115, USA
| | - Hen-Wei Huang
- Koch Institute for Integrative Cancer Research, Massachusetts Institute of Technology, Cambridge, MA 02139, USA; Department of Mechanical Engineering, Massachusetts Institute of Technology, Cambridge, MA 02139, USA; Division of Gastroenterology, Hepatology and Endoscopy, Department of Medicine, Brigham and Women's Hospital, Harvard Medical School, Boston, MA 02115, USA
| | - Abdelsalam Elrefaey Ahmed
- Division of Gastroenterology, Hepatology and Endoscopy, Department of Medicine, Brigham and Women's Hospital, Harvard Medical School, Boston, MA 02115, USA
| | - Jia Ying Liang
- Koch Institute for Integrative Cancer Research, Massachusetts Institute of Technology, Cambridge, MA 02139, USA; Department of Mechanical Engineering, Massachusetts Institute of Technology, Cambridge, MA 02139, USA; Division of Gastroenterology, Hepatology and Endoscopy, Department of Medicine, Brigham and Women's Hospital, Harvard Medical School, Boston, MA 02115, USA
| | - Giovanni Traverso
- Department of Mechanical Engineering, Massachusetts Institute of Technology, Cambridge, MA 02139, USA; Division of Gastroenterology, Hepatology and Endoscopy, Department of Medicine, Brigham and Women's Hospital, Harvard Medical School, Boston, MA 02115, USA
| |
Collapse
|
2
|
Weidlich E, Richter G, Sturm FV, Rao JR. Animal experiments with biogalvanic and biofuel cells. BIOMATERIALS, MEDICAL DEVICES, AND ARTIFICIAL ORGANS 1976; 4:277-306. [PMID: 1021155 DOI: 10.3109/10731197609118655] [Citation(s) in RCA: 28] [Impact Index Per Article: 0.6] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 12/25/2022]
Abstract
Animal experiments with biogalvanic cells have demonstrated that an average power of 80 muW can be derived continously for at least 2 years. There is a further scope to stabilize the power at 100 muW for considerable longer periods so that the chances of cardiac pacing with biogalvanic power have become bright. However, large scale efforts are necessary in in establishing the statistical reliability and the secured performance which are expensive and time consuming. Animal experiments with biofuel cells are still in preliminary stages. We derived a continous power of 40 muW (4MUW/cm2) at 575 mV over 150 days so far. This is the longest recorded period with such a high power density. The main problem in deriving higher power over longer period is to properly encapsulate the cell with materials which are hydrophilic and essentially biocompatible.
Collapse
|
3
|
Fontenier G, Freschard R, Mourot M. Design of experimentation with a platinum-magnesium bioelectric battery. BIOMATERIALS, MEDICAL DEVICES, AND ARTIFICIAL ORGANS 1975; 3:25-45. [PMID: 1139023 DOI: 10.3109/10731197509118612] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 12/25/2022]
Abstract
The utilization of metal electrodes in the fabrication of a bioelectric battery has been the subject of intensive study for several years. Up to this date, subcutaneous cathodes of black platinum or of silver-silver chloride have been used in conjunction with anodes of aluminum or zinc. The subcutaneous black platinum is not reliable as a function of time due to the growth of overlying heterogeneous tissues. The utilization of a smooth platinum cathode in the right endoauricular position allows good reliability with time, but does not allow using a large surface area. Furthermore we have a reduction of the H-+ ions and not of the oxygen. A pure Domal magnesium anode was utilized with this cathode, which seemed to be a good compromise between to battery's voltage, its lifetime, and its lack of toxicity to body tissues.
Collapse
|