1
|
Bitterer F, Bauer A, Glehr G, Brunner S, Schmidt K, Schlitt HJ, Jung EM, Hackl C. Intraoperative contrast-enhanced ultrasound has an outcome-relevant impact on surgery of primary and metastatic liver lesions. ULTRASCHALL IN DER MEDIZIN (STUTTGART, GERMANY : 1980) 2025; 46:49-56. [PMID: 38335990 DOI: 10.1055/a-2249-6791] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 02/12/2024]
Abstract
PURPOSE Complete resection of the affected tissue remains the best curative treatment option for liver-derived tumors and colorectal liver metastases. In addition to preoperative cross-sectional imaging, contrast-enhanced intraoperative ultrasound (CE-IOUS) plays a crucial role in the detection and localization of all liver lesions. However, its exact role is unclear. This study was designed to evaluate the clinical and oncological impact of using CE-IOUS in the surgical treatment of these diseases. MATERIALS AND METHODS Over the three-year study period, 206 patients with primary liver tumors and hepatic metastases were enrolled in this prospective, monocentric study to evaluate the impact of CE-IOUS in liver surgery. Secondary outcomes included comparing the sensitivity and specificity of CE-IOUS with existing preoperative imaging modalities and identifying preoperative parameters that could predict a strategic impact of CE-IOUS. In addition, the oncological significance of CE-IOUS was evaluated using a case-cohort design with a minimum follow-up of 18 months. RESULTS CE-IOUS findings led to a change in surgical strategy in 34% of cases (n=70/206). The accuracy in cases with a major change could be confirmed histopathologically in 71.4% of cases (n=25/35). The impact could not be predicted using parameters assumed to be clinically relevant. An oncological benefit of a CE-IOUS adapted surgical approach was demonstrated in patients suffering from HCC and colorectal liver metastases. CONCLUSION CE-IOUS may significantly increase R0 resection rates and should therefore be used routinely as an additional staging method, especially in complex liver surgery.
Collapse
Affiliation(s)
- Florian Bitterer
- Department of Surgery, University Hospital Regensburg Clinic and Polyclinic for Surgery, Regensburg, Germany
| | - Andreas Bauer
- Department of Surgery, University Hospital Regensburg Clinic and Polyclinic for Surgery, Regensburg, Germany
| | - Gunther Glehr
- Department of Surgery, University Hospital Regensburg Clinic and Polyclinic for Surgery, Regensburg, Germany
| | - Stefan Brunner
- Department of Surgery, University Hospital Regensburg Clinic and Polyclinic for Surgery, Regensburg, Germany
| | - Katharina Schmidt
- Department of Surgery, University Hospital Regensburg Clinic and Polyclinic for Surgery, Regensburg, Germany
| | - Hans Jürgen Schlitt
- Department of Surgery, University Hospital Regensburg Clinic and Polyclinic for Surgery, Regensburg, Germany
| | - Ernst Michael Jung
- Department of Radiology, University Hospital Regensburg, Regensburg, Germany
| | - Christina Hackl
- Department of Surgery, University Hospital Regensburg Clinic and Polyclinic for Surgery, Regensburg, Germany
| |
Collapse
|
2
|
Kupke LS, Dropco I, Götz M, Kupke P, Jung F, Stroszczynski C, Jung EM. Contrast-Enhanced Intraoperative Ultrasound Shows Excellent Performance in Improving Intraoperative Decision-Making. Life (Basel) 2024; 14:1199. [PMID: 39337981 PMCID: PMC11433090 DOI: 10.3390/life14091199] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/21/2024] [Revised: 09/15/2024] [Accepted: 09/18/2024] [Indexed: 09/30/2024] Open
Abstract
BACKGROUND The aim of this study was to evaluate the performance and the impact of contrast-enhanced intraoperative ultrasound (CE-IOUS) on intraoperative decision-making, as there is still no standardized protocol for its use. Therefore, we retrospectively analyzed multiple CE-IOUS performed in hepato-pancreatic-biliary surgery with respect to pre- and postoperative imaging and histopathological findings. METHODS Data of 50 patients who underwent hepato-pancreatic-biliary surgery between 03/2022 and 03/2024 were retrospectively collected. CE-IOUS was performed with a linear 6-9 MHz multifrequency probe connected to a high-resolution device. The ultrasound contrast agent used was a stabilized aqueous suspension of sulphur hexafluoride microbubbles. RESULTS In total, all 50 lesions indicated for surgery were correctly identified. In 30 cases, CE-IOUS was used to localize the primary lesion and to define the resection margins. In the remaining 20 cases, CE-IOUS identified an additional lesion. Fifteen of these findings were identified as malignant. In eight of these cases, the additional malignant lesion was subsequently resected. In the remaining seven cases, CE-IOUS again revealed an inoperable situation. In summary, CE-IOUS diagnostics resulted in a high correct classification rate of 95.7%, with positive and negative predictive values of 95.2% and 100.0%, respectively. CONCLUSIONS CE-IOUS shows excellent performance in describing intraoperative findings in hepato-pancreatic-biliary surgery, leading to a substantial impact on intraoperative decision-making.
Collapse
Affiliation(s)
- Laura S Kupke
- Department of Radiology, University Hospital Regensburg, 93053 Regensburg, Germany
| | - Ivor Dropco
- Department of Surgery, University Hospital Regensburg, 93053 Regensburg, Germany
| | - Markus Götz
- Department of Surgery, University Hospital Regensburg, 93053 Regensburg, Germany
| | - Paul Kupke
- Department of Surgery, University Hospital Regensburg, 93053 Regensburg, Germany
| | - Friedrich Jung
- Institute of Biotechnology, Brandenburg University of Technology Cottbus-Senftenberg, 01968 Senftenberg, Germany
| | | | - Ernst-Michael Jung
- Department of Radiology, University Hospital Regensburg, 93053 Regensburg, Germany
| |
Collapse
|
3
|
Sheriff NJ, Thomas M, Bunck AC, Peterhans M, Datta RR, Hellmich M, Bruns CJ, Stippel DL, Wahba R. Registration accuracy comparing different rendering techniques on local vs external virtual 3D liver model reconstruction for vascular landmark setting by intraoperative ultrasound in augmented reality navigated liver resection. Langenbecks Arch Surg 2024; 409:268. [PMID: 39225933 PMCID: PMC11371850 DOI: 10.1007/s00423-024-03456-z] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/13/2024] [Accepted: 08/15/2024] [Indexed: 09/04/2024]
Abstract
PURPOSE Augmented reality navigation in liver surgery still faces technical challenges like insufficient registration accuracy. This study compared registration accuracy between local and external virtual 3D liver models (vir3DLivers) generated with different rendering techniques and the use of the left vs right main portal vein branch (LPV vs RPV) for landmark setting. The study should further examine how registration accuracy behaves with increasing distance from the ROI. METHODS Retrospective registration accuracy analysis of an optical intraoperative 3D navigation system, used in 13 liver tumor patients undergoing liver resection/thermal ablation. RESULTS 109 measurements in 13 patients were performed. Registration accuracy with local and external vir3DLivers was comparable (8.76 ± 0.9 mm vs 7.85 ± 0.9 mm; 95% CI = -0.73 to 2.55 mm; p = 0.272). Registrations via the LPV demonstrated significantly higher accuracy than via the RPV (6.2 ± 0.85 mm vs 10.41 ± 0.99 mm, 95% CI = 2.39 to 6.03 mm, p < 0.001). There was a statistically significant positive but weak correlation between the accuracy (dFeature) and the distance from the ROI (dROI) (r = 0.298; p = 0.002). CONCLUSION Despite basing on different rendering techniques both local and external vir3DLivers have comparable registration accuracy, while LPV-based registrations significantly outperform RPV-based ones in accuracy. Higher accuracy can be assumed within distances of up to a few centimeters around the ROI.
Collapse
Affiliation(s)
- Nonkoh J Sheriff
- Department of General, Visceral, Cancer and Transplant Surgery, Faculty of Medicine, University of Cologne, University Hospital Cologne, Cologne, Germany
- Department of General, Visceral and Oncological Surgery, Helios Hospital Berlin-Buch, Berlin, Germany
| | - Michael Thomas
- Department of General, Visceral, Cancer and Transplant Surgery, Faculty of Medicine, University of Cologne, University Hospital Cologne, Cologne, Germany
| | - Alexander C Bunck
- Institute of Diagnostic and Interventional Radiology, Faculty of Medicine, University of Cologne, University Hospital Cologne, Cologne, Germany
| | | | - Rabi Raj Datta
- Department of General, Visceral, Cancer and Transplant Surgery, Faculty of Medicine, University of Cologne, University Hospital Cologne, Cologne, Germany
| | - Martin Hellmich
- Institute of Medical Statistics and Computational Biology, Faculty of Medicine, University of Cologne, University Hospital Cologne, Cologne, Germany
| | - Christiane J Bruns
- Department of General, Visceral, Cancer and Transplant Surgery, Faculty of Medicine, University of Cologne, University Hospital Cologne, Cologne, Germany
| | - Dirk Ludger Stippel
- Department of General, Visceral, Cancer and Transplant Surgery, Faculty of Medicine, University of Cologne, University Hospital Cologne, Cologne, Germany
| | - Roger Wahba
- Department of General, Visceral, Cancer and Transplant Surgery, Faculty of Medicine, University of Cologne, University Hospital Cologne, Cologne, Germany.
- Department of General, Visceral and Oncological Surgery, Helios Hospital Berlin-Buch, Berlin, Germany.
| |
Collapse
|
4
|
Lou C, Li YX, Tan BB, Tao CJ, Xu CC, Liao YY. Clinical value of contrast-enhanced ultrasound versus conventional ultrasound in biopsy of focal liver lesions. Acta Radiol 2024; 65:700-707. [PMID: 38856151 DOI: 10.1177/02841851241257607] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 06/11/2024]
Abstract
BACKGROUND Focal liver lesions (FLLs) are a common form of liver disease, and identifying accurate pathological types is required to guide treatment and evaluate prognosis. PURPOSE To compare and analyze the application effect of contrast-enhanced ultrasound (CEUS) and conventional ultrasound (US) in the clinical diagnosis of focal liver lesions. MATERIAL AND METHODS A retrospective analysis was performed on 682 patients with space-occupying liver lesions admitted to our hospital between December 2015 and August 2021. Of these, 280 underwent CEUS-guided biopsies and 402 underwent conventional US biopsies, with the results of each biopsy subsequently compared between the two groups. The success rate and accuracy of the biopsies and their relationship with different pathological features were also analyzed. RESULTS The success rate, sensitivity, diagnostic accuracy, positive predictive value, and negative predictive value of the CEUS group were significantly higher than those of the US group (P < 0.05). Lesion size accuracy in the CEUS group was significantly higher than that in the US group (89.29% vs. 40.55%; P < 0.05). Lesion type accuracy in the CEUS group was significantly higher than that in the US group (86.49% vs. 43.59%), and the difference between the two groups was statistically significant (P < 0.05). The logistic regression analysis indicated that malignant lesions, lesions ≥5 cm, and lesions ≤1 cm were independent factors affecting the success rate of the puncture procedure (P < 0.05). CONCLUSION The sensitivity, specificity, and diagnostic accuracy of lesion size and type in the CEUS group were higher than those in the US group.
Collapse
Affiliation(s)
- Cheng Lou
- Department of Oncology, Third Affiliated Hospital of the Naval Medical University, Shanghai, PR China
| | - Yin-Xia Li
- Department of Imaging Medicine Ultrasound Diagnosis Teaching and Research, Naval Medical University, Shanghai, PR China
| | - Bi-Bo Tan
- Department of Ultrasound and Therapy, Third Affiliated Hospital of the Naval Medical University, Shanghai, PR China
| | - Chen-Jie Tao
- Department of Oncology, Third Affiliated Hospital of the Naval Medical University, Shanghai, PR China
| | - Cheng-Chuan Xu
- Department of Ultrasound and Therapy, Third Affiliated Hospital of the Naval Medical University, Shanghai, PR China
| | - Ying-Ying Liao
- Department of Ultrasound and Therapy, Third Affiliated Hospital of the Naval Medical University, Shanghai, PR China
| |
Collapse
|
5
|
Giehl-Brown E, Dennler S, Garcia SA, Seppelt D, Oehme F, Schweipert J, Weitz J, Riediger C. 3D liver model-based surgical education improves preoperative decision-making and patient satisfaction-a randomized pilot trial. Surg Endosc 2023:10.1007/s00464-023-09915-w. [PMID: 36849565 PMCID: PMC9970129 DOI: 10.1007/s00464-023-09915-w] [Citation(s) in RCA: 4] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/11/2022] [Accepted: 01/28/2023] [Indexed: 03/01/2023]
Abstract
OBJECTIVE Hepatobiliary surgery bares obstacles to informed consent for the patients due to its complexity and related risk of postoperative complications. 3D visualization of the liver has been proven to facilitate comprehension of the spatial relationship between anatomical structures and to assist in clinical decision-making. Our objective is to utilize individual 3D-printed liver models to enhance patient satisfaction with surgical education in hepatobiliary surgery. DESIGN, SETTING We conducted a prospective, randomized pilot study comparing 3D liver model-enhanced (3D-LiMo) surgical education against regular patient education during preoperative consultation at the department of Visceral, Thoracic and Vascular Surgery, University Hospital Carl Gustav Carus, Dresden, Germany. PARTICIPANTS Of 97 screened patients, undergoing hepatobiliary surgery, 40 patients were enrolled from July 2020 to January 2022. RESULTS The study population (n = 40) was predominantly of male gender (62.5%) with a median age of 65.2 years and a high prevalence of preexisting diseases. Underlying disease, warranting hepatobiliary surgery, was malignancy in the majority of cases (97.5%). Patients in the 3D-LiMo group were more likely to feel very thoroughly educated and exhibited a higher level of satisfaction following surgical education than the control group (80 vs. 55%, n.s.; 90 vs. 65%, n.s.; respectively). Applying 3D models was also associated with enhanced understanding of the underlying disease with regard to amount (100% vs. 70%, p = 0.020) and location of liver masses (95 vs. 65%, p = 0.044). 3D-LiMo patients also demonstrated enhanced understanding of the surgical procedure (80 vs. 55%, n.s.), leading to better awareness for the occurrence of postoperative complications (88.9, vs. 68.4%, p = 0.052). Adverse event profiles were similar. CONCLUSION In conclusion, individual 3D-printed liver models increase patient satisfaction with surgical education and facilitate patients' understanding of the surgical procedure as well as awareness of postoperative complications. Therefore, the study protocol is feasible to apply to an adequately powered, multicenter, randomized clinical trial with minor modifications.
Collapse
Affiliation(s)
- Esther Giehl-Brown
- grid.412282.f0000 0001 1091 2917Department of Visceral, Thoracic and Vascular Surgery, University Hospital Carl Gustav Carus, Technische Universität Dresden, Dresden, Germany ,grid.461742.20000 0000 8855 0365National Center for Tumor Diseases (NCT/UCC), Dresden, Germany ,grid.7497.d0000 0004 0492 0584German Cancer Research Center (DKFZ), Heidelberg, Germany ,grid.412282.f0000 0001 1091 2917Faculty of Medicine, University Hospital Carl Gustav Carus, Technische Universität Dresden, Dresden, Germany ,grid.40602.300000 0001 2158 0612Helmholtz-Zentrum Dresden—Rossendorf (HZDR), Dresden, Germany
| | - Sandra Dennler
- grid.412282.f0000 0001 1091 2917Department of Visceral, Thoracic and Vascular Surgery, University Hospital Carl Gustav Carus, Technische Universität Dresden, Dresden, Germany ,grid.461742.20000 0000 8855 0365National Center for Tumor Diseases (NCT/UCC), Dresden, Germany ,grid.7497.d0000 0004 0492 0584German Cancer Research Center (DKFZ), Heidelberg, Germany ,grid.412282.f0000 0001 1091 2917Faculty of Medicine, University Hospital Carl Gustav Carus, Technische Universität Dresden, Dresden, Germany ,grid.40602.300000 0001 2158 0612Helmholtz-Zentrum Dresden—Rossendorf (HZDR), Dresden, Germany
| | - Sebastián A. Garcia
- grid.412282.f0000 0001 1091 2917Department of Visceral, Thoracic and Vascular Surgery, University Hospital Carl Gustav Carus, Technische Universität Dresden, Dresden, Germany ,grid.461742.20000 0000 8855 0365National Center for Tumor Diseases (NCT/UCC), Dresden, Germany ,grid.7497.d0000 0004 0492 0584German Cancer Research Center (DKFZ), Heidelberg, Germany ,grid.412282.f0000 0001 1091 2917Faculty of Medicine, University Hospital Carl Gustav Carus, Technische Universität Dresden, Dresden, Germany ,grid.40602.300000 0001 2158 0612Helmholtz-Zentrum Dresden—Rossendorf (HZDR), Dresden, Germany
| | - Danilo Seppelt
- grid.4488.00000 0001 2111 7257Department of Radiology, University Hospital Carl Gustav Carus Dresden, Technische Universität Dresden, Dresden, Germany
| | - Florian Oehme
- grid.412282.f0000 0001 1091 2917Department of Visceral, Thoracic and Vascular Surgery, University Hospital Carl Gustav Carus, Technische Universität Dresden, Dresden, Germany ,grid.461742.20000 0000 8855 0365National Center for Tumor Diseases (NCT/UCC), Dresden, Germany ,grid.7497.d0000 0004 0492 0584German Cancer Research Center (DKFZ), Heidelberg, Germany ,grid.412282.f0000 0001 1091 2917Faculty of Medicine, University Hospital Carl Gustav Carus, Technische Universität Dresden, Dresden, Germany ,grid.40602.300000 0001 2158 0612Helmholtz-Zentrum Dresden—Rossendorf (HZDR), Dresden, Germany
| | - Johannes Schweipert
- grid.412282.f0000 0001 1091 2917Department of Visceral, Thoracic and Vascular Surgery, University Hospital Carl Gustav Carus, Technische Universität Dresden, Dresden, Germany ,grid.461742.20000 0000 8855 0365National Center for Tumor Diseases (NCT/UCC), Dresden, Germany ,grid.7497.d0000 0004 0492 0584German Cancer Research Center (DKFZ), Heidelberg, Germany ,grid.412282.f0000 0001 1091 2917Faculty of Medicine, University Hospital Carl Gustav Carus, Technische Universität Dresden, Dresden, Germany ,grid.40602.300000 0001 2158 0612Helmholtz-Zentrum Dresden—Rossendorf (HZDR), Dresden, Germany
| | - Jürgen Weitz
- grid.412282.f0000 0001 1091 2917Department of Visceral, Thoracic and Vascular Surgery, University Hospital Carl Gustav Carus, Technische Universität Dresden, Dresden, Germany ,grid.461742.20000 0000 8855 0365National Center for Tumor Diseases (NCT/UCC), Dresden, Germany ,grid.7497.d0000 0004 0492 0584German Cancer Research Center (DKFZ), Heidelberg, Germany ,grid.412282.f0000 0001 1091 2917Faculty of Medicine, University Hospital Carl Gustav Carus, Technische Universität Dresden, Dresden, Germany ,grid.40602.300000 0001 2158 0612Helmholtz-Zentrum Dresden—Rossendorf (HZDR), Dresden, Germany
| | - Carina Riediger
- Department of Visceral, Thoracic and Vascular Surgery, University Hospital Carl Gustav Carus, Technische Universität Dresden, Dresden, Germany. .,National Center for Tumor Diseases (NCT/UCC), Dresden, Germany. .,German Cancer Research Center (DKFZ), Heidelberg, Germany. .,Faculty of Medicine, University Hospital Carl Gustav Carus, Technische Universität Dresden, Dresden, Germany. .,Helmholtz-Zentrum Dresden-Rossendorf (HZDR), Dresden, Germany.
| |
Collapse
|
6
|
Giammalva GR, Viola A, Maugeri R, Giardina K, Di Bonaventura R, Musso S, Brunasso L, Cepeda S, Della Pepa GM, Scerrati A, Mantovani G, Ferini G, Gerardi RM, Pino MA, Umana GE, Denaro L, Albanese A, Iacopino DG. Intraoperative Evaluation of Brain-Tumor Microvascularization through MicroV IOUS: A Protocol for Image Acquisition and Analysis of Radiomic Features. Cancers (Basel) 2022; 14:5335. [PMID: 36358754 PMCID: PMC9656308 DOI: 10.3390/cancers14215335] [Citation(s) in RCA: 3] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/25/2022] [Revised: 10/25/2022] [Accepted: 10/27/2022] [Indexed: 08/09/2023] Open
Abstract
Microvascular Doppler (MicroV) is a new-generation Doppler technique developed by Esaote (Esaote s.p.a., Genova, Italy), which is able to visualize small and low-flow vessels through a suppression of interfering signals. MicroV uses advanced filters that are able to differentiate tissue artifacts from low-speed blood flows; by exploiting the space-time coherence information, these filters can selectively suppress tissue components, preserving the signal coming from the microvascular flow. This technique is clinically applied to the study of the vascularization of parenchymatous lesions, often with better diagnostic accuracy than color/power Doppler techniques. The aim of this paper is to develop a reproducible protocol for the recording and collection of MicroV intraoperative ultrasound images by the use of a capable intraoperative ultrasound machine and post-processing aimed at evaluation of brain-tumor microvascularization through the analysis of radiomic features. The proposed protocol has been internally validated on eight patients and will be firstly applied to patients affected by WHO grade IV astrocytoma (glioblastoma-GBM) candidates for craniotomy and lesion removal. In a further stage, it will be generally applied to patients with primary or metastatic brain tumors. IOUS is performed before durotomy. Tumor microvascularization is evaluated using the MicroV Doppler technique and IOUS images are recorded, stored, and post-processed. IOUS images are remotely stored on the BraTIoUS database, which will promote international cooperation and multicentric analysis. Processed images and texture radiomic features are analyzed post-operatively using ImageJ, a free scientific image-analysis software based on the Sun-Java platform. Post-processing protocol is further described in-depth. The study of tumor microvascularization through advanced IOUS techniques such as MicroV could represent, in the future, a non-invasive and real-time method for intraoperative predictive evaluation of the tumor features. This evaluation could finally result in a deeper knowledge of brain-tumor behavior and in the on-going adaptation of the surgery with the improvement of surgical outcomes.
Collapse
Affiliation(s)
- Giuseppe Roberto Giammalva
- Neurosurgical Clinic, Post Graduate Residency Program in Neurologic Surgery, Department of Biomedicine Neurosciences and Advanced Diagnostics, School of Medicine, University of Palermo, 90127 Palermo, Italy
| | - Anna Viola
- Department of Radiation Oncology, REM Radioterapia srl, 95029 Viagrande, Italy
| | - Rosario Maugeri
- Neurosurgical Clinic, Post Graduate Residency Program in Neurologic Surgery, Department of Biomedicine Neurosciences and Advanced Diagnostics, School of Medicine, University of Palermo, 90127 Palermo, Italy
| | - Kevin Giardina
- Neurosurgical Clinic, Post Graduate Residency Program in Neurologic Surgery, Department of Biomedicine Neurosciences and Advanced Diagnostics, School of Medicine, University of Palermo, 90127 Palermo, Italy
| | - Rina Di Bonaventura
- Department of Neurosurgery, Fondazione Policlinico Universitario A. Gemelli IRCCS, Università Cattolica del Sacro Cuore, 00100 Rome, Italy
| | - Sofia Musso
- Neurosurgical Clinic, Post Graduate Residency Program in Neurologic Surgery, Department of Biomedicine Neurosciences and Advanced Diagnostics, School of Medicine, University of Palermo, 90127 Palermo, Italy
| | - Lara Brunasso
- Neurosurgical Clinic, Post Graduate Residency Program in Neurologic Surgery, Department of Biomedicine Neurosciences and Advanced Diagnostics, School of Medicine, University of Palermo, 90127 Palermo, Italy
| | - Santiago Cepeda
- Departamento de Neurocirugía, Hospital Universitario Río Hortega, 47012 Valladolid, Spain
| | - Giuseppe Maria Della Pepa
- Department of Neurosurgery, Fondazione Policlinico Universitario A. Gemelli IRCCS, Università Cattolica del Sacro Cuore, 00100 Rome, Italy
| | - Alba Scerrati
- Department of Translational Medicine, University of Ferrara, 44121 Ferrara, Italy
- Department of Neurosurgery, Sant’Anna University Hospital of Ferrara, 44124 Ferrara, Italy
| | - Giorgio Mantovani
- Department of Translational Medicine, University of Ferrara, 44121 Ferrara, Italy
- Department of Neurosurgery, Sant’Anna University Hospital of Ferrara, 44124 Ferrara, Italy
| | - Gianluca Ferini
- Department of Radiation Oncology, REM Radioterapia srl, 95029 Viagrande, Italy
| | - Rosa Maria Gerardi
- Neurosurgical Clinic, Post Graduate Residency Program in Neurologic Surgery, Department of Biomedicine Neurosciences and Advanced Diagnostics, School of Medicine, University of Palermo, 90127 Palermo, Italy
| | - Maria Angela Pino
- Neurosurgical Clinic, Post Graduate Residency Program in Neurologic Surgery, Department of Biomedicine Neurosciences and Advanced Diagnostics, School of Medicine, University of Palermo, 90127 Palermo, Italy
| | - Giuseppe Emmanuele Umana
- Trauma Center, Gamma Knife Center, Department of Neurosurgery, Cannizzaro Hospital, 95126 Catania, Italy
| | - Luca Denaro
- Academic Neurosurgery, Department of Neurosciences DNS, University of Padua, 35128 Padua, Italy
| | - Alessio Albanese
- Department of Neurosurgery, Fondazione Policlinico Universitario A. Gemelli IRCCS, Università Cattolica del Sacro Cuore, 00100 Rome, Italy
| | - Domenico Gerardo Iacopino
- Neurosurgical Clinic, Post Graduate Residency Program in Neurologic Surgery, Department of Biomedicine Neurosciences and Advanced Diagnostics, School of Medicine, University of Palermo, 90127 Palermo, Italy
| |
Collapse
|
7
|
Werner JM, Zidek M, Kammerer S, da Silva NPB, Jung F, Schlitt HJ, Hornung M, Jung EM. Intraoperative contrast-enhanced ultrasound can have a crucial role in surgical decision-making during hepato-pancreatico-biliary surgery - Analysis of impact and input. Clin Hemorheol Microcirc 2021; 78:103-116. [PMID: 33554890 DOI: 10.3233/ch-201031] [Citation(s) in RCA: 6] [Impact Index Per Article: 1.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/05/2023]
Abstract
OBJECTIVE To assess the impact and procedural input of intraoperative ultrasound (IOUS) with contrast-enhanced ultrasound (CEUS) and ultrasound elastography on surgical decision making during the procedure and consequently the outcome after hepato-pancreatico-biliary (HPB) surgery. MATERIALS AND METHODS Data of 50 consecutive patients, who underwent HPB surgery from 04/2018 to 07/2018 were prospectively collected for this study. During surgery, IOUS with a high-resolution ultrasound device using CEUS after bolus injection of 2.4-5 ml dulphur hexafluoride microbubbles using a 6-9 MHz probe and a share wave and strain elastography was performed by an experienced examiner. Process and time analysis were carried out using mobile phone timer. RESULTS The IOUS with CEUS and elastography correctly identified 42 malignant tumors and 4 benign lesions. In 3 cases, the examination provided false positive result (identifying 3 benign lesions as malignant) and in 1 case a malignant lesion was incorrectly assessed as benign (sensitivity 97,7%, specificity 57,1%, PPV 93,3% and NPV 80%).The specific question by the surgeon could be answered successfully in 98% of the cases. In 76% of the cases, there was a modification (42%) or a fundamental change (34%) of the planned surgical approach due to the information provided by the IOUS. Within the last group, the IOUS had a major impact on therapy outcome. In 7 patients an additional tumor resection was required, in 5 patients the tumor was assessed as inoperable, and in total in 5 patients an intraoperative RFA (4/5) or postoperative RITA (1/5) was required.Regarding procedural input, there was only a slight, but significant difference between the transport and set-up times before the intraoperative use (mean: 14 min 22 s) and the return transport (mean 13 min 6 s), (p = 0,038). The average examination time was 14 minutes, which makes only one third of the overall time demand. CONCLUSION Combination of IOUS with CEUS and elastography in oncological HPB surgery provides valuable information that affects surgical decision-making. The procedural input of about 45 minutes seems to be a good investment considering the improvement of the surgical procedure and a significant modification of the therapy approach in the majority of the cases.
Collapse
Affiliation(s)
- Jens Martin Werner
- Department of Surgery, University Hospital Regensburg, Regensburg, Germany
| | - Martin Zidek
- Department of Surgery, University Hospital Regensburg, Regensburg, Germany
| | - Sylvia Kammerer
- Department of Radiology, University Hospital Regensburg, Regensburg, Germany
| | | | - Friedrich Jung
- Institute of Biotechnology, Molecular Cell Biology, Brandenburg University of Technology, Senftenberg, Germany
| | | | - Matthias Hornung
- Department of Surgery, University Hospital Regensburg, Regensburg, Germany
| | - Ernst-Michael Jung
- Department of Radiology, University Hospital Regensburg, Regensburg, Germany
| |
Collapse
|
8
|
Bitterer F, Hornung M, Platz Batista da Silva N, Schlitt HJ, Stroszczynski C, Wege AK, Jung EM. In vivo detection of breast cancer liver metastases in humanized tumour mice using tumour specific contrast agent BR55®. Clin Hemorheol Microcirc 2021; 76:559-572. [PMID: 32924994 DOI: 10.3233/ch-200898] [Citation(s) in RCA: 4] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/25/2022]
Abstract
OBJECTIVE To investigate the diagnostic accuracy of high-resolution ultrasound (HRU) for the detection of hepatic metastases of breast cancer in a humanized tumour mouse (HTM) using clinical standard technology. In addition, the efficiency of standard contrast-enhanced ultrasound (CEUS) [microbubbles of sulphur hexafluoride] and CEUS using a novel VEGFR2-targeted contrast agent [BR55®] was examined. METHODS A total of 14 HTM were sonographically examined twice. In addition to a human immune system, the animals developed hepatic tumour lesions after intrahepatic injection of BT-474 breast cancer cells. Digital cine loops from the arterial phase (15-35 sec), the portal venous phase (35-90 sec) and the late phase (3-15 min) of the entire liver were analysed. Data were correlated to histopathology. RESULTS After 9 months, half of the mice (7/14) revealed the development of hepatic breast cancer metastases. The detection limit was 1 mm tumour diameter. In particular, the use of targeted contrast media reduced the needed tumour diameter and helped to precisely classify tumour tissue. In 93% (13/14), the findings of ultrasound could be approved by histological examination by the pathologist. CONCLUSIONS This study in HTM demonstrated the high feasibility of tumour specific contrast media and standard HRU contrast agents to detect early liver metastases.
Collapse
Affiliation(s)
- Florian Bitterer
- Department of Surgery, University Hospital Regensburg, Regensburg, Germany
| | - Matthias Hornung
- Department of Surgery, University Hospital Regensburg, Regensburg, Germany
| | | | - Hans J Schlitt
- Department of Surgery, University Hospital Regensburg, Regensburg, Germany
| | | | - Anja K Wege
- Department of Gynecology and Obstetrics, University Medical Center Regensburg, Regensburg, Germany
| | - Ernst-Michael Jung
- Department of Radiology, University Hospital Regensburg, Regensburg, Germany
| |
Collapse
|