1
|
Ikeda N, Nagata T, Umemura T, Watanabe M. Total Sealing Technique: A Preliminary Study on a Novel Surgical Approach That Significantly Reduces the Incidence of Upper Extremity Lymphedema Following Axillary Dissection in Patients with Breast Cancer. Cancers (Basel) 2025; 17:1285. [PMID: 40282461 PMCID: PMC12026092 DOI: 10.3390/cancers17081285] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/31/2025] [Revised: 03/05/2025] [Accepted: 04/08/2025] [Indexed: 04/29/2025] Open
Abstract
The primary goal in treating patients with breast cancer who have positive axillary lymph nodes is to achieve optimal tumor control while minimizing side effects that include breast cancer-related lymphedema (BCRL) [...].
Collapse
Affiliation(s)
- Naoya Ikeda
- Department of Surgery, KIWA Hospital, Wakayama 648-0085, Japan;
- Department of Forensic Medicine, Wakayama Medical University, Wakayama 641-8509, Japan
| | - Takuya Nagata
- Department of Surgery, Toho University Ohashi Medical Center, Tokyo 153-8515, Japan; (T.N.); (M.W.)
| | - Teiji Umemura
- Department of Surgery, KIWA Hospital, Wakayama 648-0085, Japan;
| | - Manabu Watanabe
- Department of Surgery, Toho University Ohashi Medical Center, Tokyo 153-8515, Japan; (T.N.); (M.W.)
| |
Collapse
|
2
|
Zhao J, Liang G, Huang H, Hong K, Pan J, Yang W, Liu J, Zeng L. Intravenous Tranexamic Acid Significantly Improved Visualization and Shortened the Operation Time in Arthroscopic Rotator Cuff Repair: A Systematic Review and Meta-analysis of Level I and II Studies. Arthroscopy 2024; 40:592-601. [PMID: 37423470 DOI: 10.1016/j.arthro.2023.06.055] [Citation(s) in RCA: 2] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 02/16/2023] [Revised: 06/23/2023] [Accepted: 06/23/2023] [Indexed: 07/11/2023]
Abstract
PURPOSE To further clarify the role of tranexamic acid (TXA) in arthroscopic rotator cuff repair (ARCR), especially visual field clarity and operation time. METHODS We searched the PubMed, Cochrane Library, and Embase databases to find prospective randomized controlled clinical trials (RCTs) examining the use of TXA in ARCR. All included RCTs were evaluated for methodological quality using the Cochrane Collaboration's risk of bias tool. We used Review Manager 5.3 for meta-analysis and calculated the weighted mean difference (WMD) and 95% confidence interval (CI) of the related outcome indicators. The GRADE system was used to evaluate the strength of the clinical evidence provided by the included studies. RESULTS Six RCTs (3 Level I, 3 Level II) from four countries or regions were included in this study: 2 studies used intra-articular (IA) TXA, and 4 studies used intravenous TXA. A total of 451 patients underwent ARCR, including 227 patients in the TXA group and 224 patients in the non-TXA group. In 2 RCTs evaluating good visualization, intravenous TXA achieved a better surgical field of view in ARCR compared to the control group (P =.036; P = .045). Meta-analysis showed that compared with non-TXA, intravenous TXA shortened the operation time (WMD = -12.87 min, 95% CI: -18.81 to -6.93). These two RCTs did not reveal a statistically significant difference in the impact of intravenous TXA and non-TXA on mean arterial pressure (MAP) (P = .306; P = .549). Compared with epinephrine (EPN), IA TXA had no significant effects on improving the visual field clarity under arthroscopy, shortening the operation time or reducing the total amount of irrigation fluid (P > .05). Compared with saline irrigation, IA TXA improved the surgical field of vision and shortened the operation time (P < .001). No adverse events were reported for either intravenous TXA or IA TXA. CONCLUSIONS Intravenous TXA can shorten the operation time of ARCR, and the conclusions of existing RCTs suggest that intravenous TXA can improve visual field clarity during ARCR, thus supporting the application of intravenous TXA in ARCR. Compared with EPN, IA TXA was not better at improving the visual field clarity under arthroscopy and shortening the operation time, but it was better than saline irrigation. LEVEL OF EVIDENCE Level II, systematic review and meta-analysis of Level I and II studies.
Collapse
Affiliation(s)
- Jinlong Zhao
- The Second Clinical College of Guangzhou University of Chinese Medicine, Guangzhou, China; The Second Affiliated Hospital of Guangzhou University of Chinese Medicine (Guangdong Provincial Hospital of Chinese Medicine), Guangzhou, China; The Research Team on Bone and Joint Degeneration and Injury of Guangdong Provincial Academy of Chinese Medical Sciences, Guangzhou, China
| | - Guihong Liang
- The Second Clinical College of Guangzhou University of Chinese Medicine, Guangzhou, China; The Second Affiliated Hospital of Guangzhou University of Chinese Medicine (Guangdong Provincial Hospital of Chinese Medicine), Guangzhou, China; The Research Team on Bone and Joint Degeneration and Injury of Guangdong Provincial Academy of Chinese Medical Sciences, Guangzhou, China
| | - Hetao Huang
- The Second Affiliated Hospital of Guangzhou University of Chinese Medicine (Guangdong Provincial Hospital of Chinese Medicine), Guangzhou, China
| | - Kunhao Hong
- The Fifth Clinical College of Guangzhou University of Chinese Medicine, Guangzhou, China; Guangdong Second Chinese Medicine Hospital (Guangdong Province Engineering Technology Research Institute of Traditional Chinese Medicine), Guangzhou, China
| | - Jianke Pan
- The Second Affiliated Hospital of Guangzhou University of Chinese Medicine (Guangdong Provincial Hospital of Chinese Medicine), Guangzhou, China
| | - Weiyi Yang
- The Second Affiliated Hospital of Guangzhou University of Chinese Medicine (Guangdong Provincial Hospital of Chinese Medicine), Guangzhou, China
| | - Jun Liu
- The Research Team on Bone and Joint Degeneration and Injury of Guangdong Provincial Academy of Chinese Medical Sciences, Guangzhou, China; The Fifth Clinical College of Guangzhou University of Chinese Medicine, Guangzhou, China; Guangdong Second Chinese Medicine Hospital (Guangdong Province Engineering Technology Research Institute of Traditional Chinese Medicine), Guangzhou, China
| | - Lingfeng Zeng
- The Second Clinical College of Guangzhou University of Chinese Medicine, Guangzhou, China; The Second Affiliated Hospital of Guangzhou University of Chinese Medicine (Guangdong Provincial Hospital of Chinese Medicine), Guangzhou, China; The Research Team on Bone and Joint Degeneration and Injury of Guangdong Provincial Academy of Chinese Medical Sciences, Guangzhou, China.
| |
Collapse
|
3
|
Wang X, Han Z, Zhang G, Zhang S, Li Z, Tian H. Safety and Efficacy of a Novel Hemostatic Powder in Total Knee Arthroplasty. Clin Appl Thromb Hemost 2024; 30:10760296241306749. [PMID: 39710938 DOI: 10.1177/10760296241306749] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/24/2024] Open
Abstract
This retrospective study evaluated the safety and efficacy of SURGICEL® Powder-Absorbable Hemostatic Powder (SP) made from oxidized regenerated cellulose (ORC) in total knee arthroplasty (TKA). Ninety-one patients who underwent TKA at Peking University Third Hospital between January 2024 and July 2024 were retrospectively analyzed. Hemostatic effectiveness was evaluated by comparing perioperative blood loss, hemoglobin (Hb) levels, hematocrit (HCT), and transfusion rates. Clinical safety was assessed by comparing complication rates, operation time, visual analog scale (VAS) scores, and postoperative fever. Finally, 85 patients were included: 43 in the SP group (using SP) and 42 in the control group (not using SP). There were no significant differences in age, sex, height, weight, preoperative HCT, or Hb levels. The volume of perioperative blood loss within 3 days in the SP group was reduced by approximately 154 ml compared with that in the control group. The Hb and HCT levels in the SP group were higher on the first, second, and third days after surgery, and there were significant differences between the two groups in terms of repeated measurements of HCT and Hb levels within 3 days postoperatively. There were no statistically significant differences in the operation time, postoperative VAS scores, complications, transfusion rates, or postoperative fever. In conclusion, this study confirmed that SP can significantly reduce perioperative blood loss in TKA without negatively affecting clinical outcomes.
Collapse
Affiliation(s)
- Xinguang Wang
- Department of Orthopedics, Peking University Third Hospital, Beijing, China
| | - Zhencan Han
- Department of Orthopedics, Peking University Third Hospital, Beijing, China
| | - Guowei Zhang
- Department of Orthopedics, Peking University Third Hospital, Beijing, China
| | - Shantao Zhang
- Department of Orthopedics, Muping District Traditional Chinese Medicine Hospital, Yantai City, China
| | - Zijian Li
- Department of Orthopedics, Peking University Third Hospital, Beijing, China
| | - Hua Tian
- Department of Orthopedics, Peking University Third Hospital, Beijing, China
| |
Collapse
|
4
|
Li B, Pan W, Sun X, Qin K, Bai G, Bao H, Huang Y, Ma J. Hemostatic effect and safety evaluation of oxidized regenerated cellulose in total knee arthroplasty- a randomized controlledtrial. BMC Musculoskelet Disord 2023; 24:797. [PMID: 37805527 PMCID: PMC10559430 DOI: 10.1186/s12891-023-06932-7] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 06/04/2023] [Accepted: 09/29/2023] [Indexed: 10/09/2023] Open
Abstract
BACKGROUND Oxidized regenerated cellulose (ORC) is a type of biodegradable hemostatic material, which has been widely used in the field of surgery. However, its hemostatic effect in patients undergoing total knee arthroplasty (TKA) is uncertain. Accordingly, this study investigated the effectiveness and safety of ORC in patients receiving TKA. METHODS Seventy patients undergoing unilateral TKA were randomized into blank control group and ORC (2 pieces of ORC placed in the joint cavity) groups. Then, the two groups were compared for primary (perioperative blood loss [total blood loss, intraoperative blood loss, and hidden blood loss] and hemoglobin drop values) and secondary (coagulation indicators, inflammatory indicators,operation time, and complication rates) outcomes. RESULTS The total blood loss in the ORC group was 902.32 ± 307.82 mL, which was statistically significantly lower than that in the control group (1052.25 ± 308.44 mL) (P < 0.05). Postoperative hidden blood loss was also statistically markedly lower in the ORC group (801.61 ± 298.80 mL) than in the control group (949.96 ± 297.59 mL) (P < 0.05). There was no significant difference between the two groups in terms of coagulation indicators, inflammatory indicators, operation time, and complication rates. CONCLUSION In conclusion, our prospective RCT study proved that regenerated oxidized cellulose can be used safely in vivo and can effectively reduce postoperative blood loss in patients, which is a potential method for preventing blood loss after TKA. TRIAL REGISTRATION This prospective RCT was reviewed and approved by the Ethics Committee of Honghui Hospital of Xi'an Jiaotong University (No: 202,211,007) and was designed and conducted according to the rules of the Declaration of Helsinki. Written informed consent was obtained from patients or their legal guardians.
Collapse
Affiliation(s)
- Bowei Li
- Department of Knee Joint Surgery, Honghui Hospital, Xi'an Jiaotong University, 555 East Friendship Road, South Gate, Xi'an, 710054, Shaanxi Province, China
- Xi'an Medical University, Xi'an, 710068, Shaanxi Province, China
| | - Wenjie Pan
- Department of Knee Joint Surgery, Honghui Hospital, Xi'an Jiaotong University, 555 East Friendship Road, South Gate, Xi'an, 710054, Shaanxi Province, China
| | - Xiaobo Sun
- Department of Knee Joint Surgery, Honghui Hospital, Xi'an Jiaotong University, 555 East Friendship Road, South Gate, Xi'an, 710054, Shaanxi Province, China
| | - Kai Qin
- Department of Knee Joint Surgery, Honghui Hospital, Xi'an Jiaotong University, 555 East Friendship Road, South Gate, Xi'an, 710054, Shaanxi Province, China
| | - Guoyang Bai
- Department of Knee Joint Surgery, Honghui Hospital, Xi'an Jiaotong University, 555 East Friendship Road, South Gate, Xi'an, 710054, Shaanxi Province, China
| | - Huanli Bao
- Department of Knee Joint Surgery, Honghui Hospital, Xi'an Jiaotong University, 555 East Friendship Road, South Gate, Xi'an, 710054, Shaanxi Province, China
| | - Yuanchi Huang
- Department of Knee Joint Surgery, Honghui Hospital, Xi'an Jiaotong University, 555 East Friendship Road, South Gate, Xi'an, 710054, Shaanxi Province, China.
| | - Jianbing Ma
- Department of Knee Joint Surgery, Honghui Hospital, Xi'an Jiaotong University, 555 East Friendship Road, South Gate, Xi'an, 710054, Shaanxi Province, China.
| |
Collapse
|
5
|
Heo DH, Park DY, Hong YH, Kim D, Kim JS. Temperature change of epidural space by radiofrequency use in biportal endoscopic lumbar surgery: safety evaluation of radiofrequency. EUROPEAN SPINE JOURNAL : OFFICIAL PUBLICATION OF THE EUROPEAN SPINE SOCIETY, THE EUROPEAN SPINAL DEFORMITY SOCIETY, AND THE EUROPEAN SECTION OF THE CERVICAL SPINE RESEARCH SOCIETY 2023; 32:2769-2775. [PMID: 37069443 DOI: 10.1007/s00586-023-07719-z] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 12/26/2022] [Revised: 03/12/2023] [Accepted: 04/10/2023] [Indexed: 04/19/2023]
Abstract
PURPOSE Articles evaluating radiofrequency (RF) safety are insufficient. Thus, the purpose of this study was to investigate RF safety during biportal endoscopic lumbar decompressive laminotomy by measuring epidural temperature after RF use. METHODS Both in vitro cadaveric study and in vivo study were performed. The epidural temperature was measured at epidural space after RF use in three cadavers. The epidural temperature was measured and analysed according to RF mode, RF power, RF usage time, and saline irrigation patency. In the in vivo study, the epidural temperature was measured after biportal endoscopic surgery. Epidural temperatures were measured around ipsilateral and contralateral traversing nerve roots after 1-s use of RF. RESULTS In the in vivo study, epidural space temperature was increased by 0.31 ± 0.16 °C ipsilaterally and 0.29 ± 0.09° contralaterally after RF use in coagulation mode 1. The epidural temperature of epidural space was increased by 0.21 ± 0.13 °C ipsilaterally and 0.15 ± 0.21 °C contralaterally after RF use in high mode 2. In the in vitro study, epidural temperature was significantly increased with a long duration of RF use and a poor patency of irrigation fluid. CONCLUSION The use of RF in biportal endoscopic spine surgery might be safe. In order to reduce indirect thermal injuries caused by RF use, it might be necessary to reduce RF use time and maintain continuous saline irrigation patency well.
Collapse
Affiliation(s)
- Dong Hwa Heo
- Endoscopic Spine Surgery Center, Neurosurgery, Champodonamu Spine Hospital, Seoul, South Korea
| | - Don Yong Park
- Department of Orthopaedic Surgery, David Geffen School of Medicine at University of California Los Angeles, Los Angeles, CA, USA
| | - Young Ho Hong
- Endoscopic Spine Surgery Center, Neurosurgery, Champodonamu Spine Hospital, Seoul, South Korea
| | - Deahwan Kim
- Neurosurgery, Seoul Top-Spine Hospital, Seoul, South Korea
| | - Jin Sung Kim
- Department of Neurosurgery, Seoul St. Mary's Hospital, The Catholic University of Korea, Seoul, South Korea.
| |
Collapse
|
6
|
Thermal Dynamics of a Novel Radio-Frequency Device for Endoscopic Spine Surgery: An Experimental Model. Spine (Phila Pa 1976) 2022; 47:720-729. [PMID: 35019880 DOI: 10.1097/brs.0000000000004320] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 02/01/2023]
Abstract
STUDY DESIGN Experimental study. OBJECTIVE In this study, the ambient temperature of a radiofrequency (RF) electrode tip was compared and analyzed in terms of products, mode, flow quantity, and flow rate. SUMMARY OF BACKGROUND DATA Endoscopic spine surgery is a widely used operation for degenerative lumbar stenosis and herniated lumbar disc. To perform endoscopic spine surgery, dedicated instruments like a RF generator and electrode are essential. METHODS An evaluation system capable of measuring temperature under equal conditions at a certain distance from the electrode tip was manufactured. The distance between the electrode tip and the temperature sensor was set to 1, 5, and 10 mm. The flow quantities of 0, 50, 100, and 150 mL/min and the flow rates of 0, 0.20, 0.53, and 0.80 m/s were compared and statistically analyzed. RESULTS The temperatures measured in the experiments conducted on the four combinations of RF device showed similar values, and showed differences according to the characteristics of each mode of the RF. As the distance between the electrode tip and the temperature sensor increased, the temperature decreased, and as flow quantity or flow rate increased, the temperature decreased. The maximum temperatures differed significantly according to flow quantity, between flow quantities of 0 and 100 mL/min (P = 0.03) and between 0 and 150 mL/min (P ≤ 0.01). The maximum temperatures also differed significantly between the flow rate of 0 m/s, and the flow rates of 0.20, 0.53, and 0.80 m/s, with P ≤ 0.01 in all three comparisons. CONCLUSION This is the first study in which we made a customized RF temperature evaluation system and verified the temperature changes in various environments. When irrigation was performed, we could confirm that the maximum temperature was less than 60°C. Irrigation is considered essential in endoscopic spine surgery. LEVEL OF EVIDENCE 3.
Collapse
|
7
|
Quantifying the magnitude of local tendon injury from electrosurgical transection. J Shoulder Elbow Surg 2022; 31:832-838. [PMID: 34582992 DOI: 10.1016/j.jse.2021.08.020] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 05/29/2021] [Revised: 07/27/2021] [Accepted: 08/17/2021] [Indexed: 02/01/2023]
Abstract
BACKGROUND Electrocautery is a common surgical technique and is often used during shoulder arthroplasty to elevate or transect the subscapularis tendon. The relative amount of tissue damage caused by cautery as opposed to sharp transection is not currently known. The purpose of this study was to examine local tissue damage resulting from electrocautery vs. sharp transection with a scalpel. We hypothesized that the electrosurgical unit would cause higher collateral tissue damage and cell death compared with sharp transection. METHODS Twelve cadaveric ovine shoulders were randomized to either the electrosurgical or sharp transection group. The infraspinatus tendon was isolated, and a partial-thickness transection was made using either a monopolar electrosurgical device (Bovie) or No. 10 scalpel blade. Tendon explants were then visualized with confocal microscopy to evaluate tissue architecture. A live/dead assay was performed using microscopy imaging analysis software. Comparisons between Bovie and scalpel transection were made using the Mann-Whitney U test, and the cell death percentage at standardized distances from the transection site was compared between groups using a mixed-model analysis. Significance was defined at P < .05. RESULTS The cellular and tendon fibril architecture was well maintained beyond the scalpel transection site, whereas Bovie transection disrupted the architecture beyond its transection path. The percentage of dead cells in the Bovie group (74.9% ± 31.2%) was significantly higher than that in the scalpel group (27.6% ± 29.9%, P = .0004). Compared with the transection site, the cell death percentage after Bovie transection significantly declined at 2.5 mm whereas that after scalpel transection significantly declined at 1 mm from the transection site. CONCLUSION There was a significantly higher dead cell percentage in the Bovie transection group, indicating extensive damage beyond the local incision site, compared with sharp transection. Electrosurgical transection of the ovine infraspinatus tendon ex vivo caused higher cell death and greater tissue architecture disruption compared with sharp scalpel transection.
Collapse
|
8
|
Kuhaimi TA, Alenezi G, Alawaji A, Alshaikh M, Bauones S. Intra-articular hip joint osteoid osteoma: Challenging diagnosis and percutaneous radiofrequency ablation treatment. Radiol Case Rep 2021; 16:3315-3320. [PMID: 34484539 PMCID: PMC8403707 DOI: 10.1016/j.radcr.2021.07.072] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/18/2021] [Revised: 07/24/2021] [Accepted: 07/25/2021] [Indexed: 01/03/2023] Open
Abstract
Atypical intra-articular osteoid osteoma can be difficult to diagnose and challenging to treat. We report a case of a right acetabular subchondral intra-articular osteoid osteoma in a young male patient which was initially diagnosed as femoroacetabular impingement due to its atypical clinical and radiological presentations. After fully working up the patient the lesion was successfully treated with percutaneous CT-guided low-power bipolar radiofrequency ablation using several per procedural articular cartilage thermal protective measures including intra-articular thermocouple, and continuous per procedural joint space cooling with Dextrose 5% solution. A precise RFA electrode placement, using the No-touch technique, and applying different passive and active thermal protective measures were helpful in avoiding collateral damage of the hip joint articular cartilages. atypical intra-articular osteoid osteomas necessitate pertinent correlation between the clinical and radiological presentations. As far as intra-articular or subchondral nidus ablation is concerned, thermal protective measures should be considered.
Collapse
Affiliation(s)
- Talal Al Kuhaimi
- Department of Interventional Radiology, Medical Imaging Administration, King Fahad Medical City, Riyadh, Kingdom of Saudi Arabia
| | - Gaied Alenezi
- Department of Musculoskeletal Radiology, Medical Imaging Administration, King Fahad Medical City, Riyadh, Kingdom of Saudi Arabia
| | - Aliya Alawaji
- Department of Musculoskeletal Radiology, Medical Imaging Administration, King Fahad Medical City, Riyadh, Kingdom of Saudi Arabia
| | - Mohammed Alshaikh
- Department of Interventional Radiology, Medical Imaging Administration, King Fahad Medical City, Riyadh, Kingdom of Saudi Arabia
| | - Salem Bauones
- Department of Musculoskeletal and Intervention Radiology, Medical Imaging Administration, King Fahad Medical City, Riyadh, Kingdom of Saudi Arabia
| |
Collapse
|
9
|
Wiegand MJ, Kubacki GW, Gilbert JL. Electrocautery-induced molten metal particle generation from total joint replacements: Morphology and chemistry. J Biomed Mater Res B Appl Biomater 2021; 109:2057-2067. [PMID: 33915033 DOI: 10.1002/jbm.b.34853] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/29/2020] [Revised: 03/12/2021] [Accepted: 04/16/2021] [Indexed: 11/10/2022]
Abstract
Electrosurgical techniques are used during surgery to cauterize, and their damaging effects have primarily been documented in terms of tissue necrosis, charring, and localized heat accumulation. Metallic implants as well as the surgical blade can experience incidental electrosurgical current arcing that results in the generation and transfer of melted metallic particles. This work examines the composition, particle size distribution, and chemical state of the melted alloy surfaces and particles produced in vitro. Using scanning electron microscopy and energy dispersive spectroscopy, a flash-melting particle generation phenomenon between source 304 SSL blades and polished cobalt-chromium-molybdenum (CoCrMo) and titanium-6-aluminum-4-vandaium (Ti6Al4V) surfaces was documented where 304 SSL mixed heterogeneously with the CoCrMo and Ti6Al4V ejecting "splatter" particles from the cautery site. The spherical micron-sized particles were embedded with sub-micron-sized particles with 42% of the total sample population measuring between 0.25 and 0.35 μm in diameter. CoCrMo-304 SSL particles were principally made of high concentrations of iron, oxygen, and nickel with embedded sub-micron-sized particles containing oxygen, chromium, and cobalt with lower concentrations of iron and molybdenum. Ti6Al4V-304 SSL interactions resulted in similar micron-sized particles made up of high concentrations of iron, nickel, and chromium with embedded sub-micron-sized particles containing titanium, oxygen, and small amounts of aluminum. X-ray photoelectron spectroscopy of damaged CoCrMo surfaces confirmed the presence of chromium (VI) following dry electrocautery contact in coagulation mode. The structural effects of electrocautery-induced damage are becoming visible in retrieval analysis, but the long-term physiological implications during the lifetime of the implant from this damage mode have yet to be defined.
Collapse
Affiliation(s)
- Michael J Wiegand
- Department of Bioengineering, Clemson University, Clemson, South Carolina, USA.,Clemson University-Medical University of South Carolina Program in Bioengineering, Clemson University, Charleston, South Carolina, USA
| | - Gregory W Kubacki
- Department of Biomedical and Chemical Engineering, Syracuse University, Syracuse, New York, USA.,Syracuse Biomaterials Institute, Syracuse University, Syracuse, New York, USA
| | - Jeremy L Gilbert
- Department of Bioengineering, Clemson University, Clemson, South Carolina, USA.,Clemson University-Medical University of South Carolina Program in Bioengineering, Clemson University, Charleston, South Carolina, USA
| |
Collapse
|
10
|
van Eck CF, van Meel TA, van den Bekerom MP, Zijl JA, Kooistra B. Heat-Related Complications from Radiofrequency and Electrocautery Devices Used in Arthroscopic Surgery: A Systematic Review. Arthrosc Sports Med Rehabil 2021; 3:e605-e613. [PMID: 34027473 PMCID: PMC8129439 DOI: 10.1016/j.asmr.2020.12.002] [Citation(s) in RCA: 5] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/02/2020] [Accepted: 12/20/2020] [Indexed: 11/30/2022] Open
Abstract
Purpose To investigate the occurrence of heat-related complications from radiofrequency and electrocautery devices in patients undergoing arthroscopic surgery. Methods A systematic review was performed using the PubMed/Medline, Embase, CINAHL (Cumulative Index to Nursing and Allied Health Literature), and Cochrane databases, in accordance with the Preferred Reporting Items for Systematic Reviews and Meta-Analyses (PRISMA) guidelines. All studies reporting complications after arthroscopy using electrosurgery devices were included. Only English- and Dutch-language articles were included. Basic science/nonclinical studies/human cadaveric studies and animal studies were excluded. Article selection was performed by 2 separate reviewers. Interobserver agreement of the selection procedure was determined by Cohen’s kappa. All included articles were critically appraised using an adapted version of the ROBINS-I tool. Results Twenty-five studies were included in this systematic review. A total of 309 cases of heat-related complications were identified. Chondrolysis was present in 45 cases and dermal burns in 15 cases. Axillary nerve injuries were reported in 197 cases of arthroscopic adhesive capsulitis release. However, it was unclear whether these injuries were directly related to the overheating of the arthroscopic fluid. No one specific risk factor for thermal complications was identified, but related factors included the leakage of the arthroscopy fluid, use of a thermal device continuously for a long period of time, proximity of the thermal device to the tissue, intra-articular local anesthetic injection or the use of intra-articular pain pumps, and certain surgical procedures, such as thermal capsulorrhaphy, capsular release, and synovectomy. Conclusions The most common heat-related complications in arthroscopy are dermal burns and chondrolysis. Risk factors include leakage of arthroscopy fluid, use of a thermal device, intra-articular anesthetics/pain pumps, and performing specific surgical procedures. Level of Evidence Systematic review of level III-IV studies.
Collapse
Affiliation(s)
- Carola F. van Eck
- Department of Orthopaedic Surgery/Orthopaedic Engineering & Sports Medicine Laboratory, University of Pittsburgh, Pittsburgh, PA
- Address correspondence to Carola F. van Eck, M.D., Ph.D., F.A.A.O.S., UPMC Lemieux Sports Complex, 8000 Cranberry Springs Dr., Cranberry Township, PA 16066.
| | - Tim A.C. van Meel
- Department of General Surgery, Amphia Ziekenhuis, Breda, the Netherlands
| | | | - Jacco A.C. Zijl
- Department of Orthopaedic Surgery, St. Antonius Ziekenhuis, Utrecht, the Netherlands
| | - Bauke Kooistra
- Department of Orthopaedic Surgery, Onze Lieve Vrouwe Gasthuis Amsterdam, the Netherlands
| |
Collapse
|