1
|
Van Meirhaeghe JP, Harris IA, Cuthbert A, Lorimer M, McAuliffe M, Adie S, Molnar R. The influence of implant factors on patient outcomes in primary total knee arthroplasty. J Orthop 2024; 58:154-160. [PMID: 39157416 PMCID: PMC11326491 DOI: 10.1016/j.jor.2024.07.011] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 05/02/2024] [Accepted: 07/15/2024] [Indexed: 08/20/2024] Open
Abstract
Background The influence of implant factors on patient-reported outcome measures (PROMS) after total knee arthroplasty (TKA) has previously been studied but findings are often inconsistent, restricted in scope and biased by confounding factors. This study aims to determine the association between implant-related factors and early post-operative PROMs after TKA. Methods Using data from the Australian Orthopaedic Association National Joint Replacement Registry (AOANJRR) PROMs program, the study included 9487 primary TKA procedures performed in 43 hospitals from July 31, 2018 to December 31, 2020. Data included baseline demographic data, surgical details and PROMs collected pre- and 6 months post-operatively. Seven prosthesis characteristics were incorporated in the multivariable model, with proportional odds ordinal regression analysis used to assess their effects on post-operative Oxford knee score (OKS) and joint pain. Adjustments were made for pre-operative OKS and joint pain, as well as potential patient confounders. Results At six months, fixed bearing implants showed higher odds of better OKS compared to mobile bearing implants (odds ratio [OR] = 1.20, 95 % confidence interval [CI] 1.06-1.37. p < 0.004). Similar findings were found with the use of image derived instrumentation (IDI) (OR = 1.27, 95 % CI 1.11-1.46, p < 0.001), robotic assisted vs. non-navigated knees (OR = 1.21, 95 % CI 1.06-1.38, p < 0.005) and no patella resurfacing (OR = 1.10, 95 % CI 1.01-1.20, p < 0.032). For lower pain scores at six months, the use of highly crosslinked polyethylene (OR = 1.12, 95 % CI 1.02-1.22, p < 0.015), cemented femoral components (OR = 1.11, 95 % CI 1.01-1.22, p < 0.024), IDI (OR = 1.20, 95 % CI 1.05-1.37, p < 0.009) or no patella resurfacing (OR = 1.10, 95 % CI 1.01-1.20, p < 0.034) were associated. Conclusion Utilizing a fixed bearing or robotic assistance correlated with improved OKS scores, whereas highly crosslinked polyethylene or cemented femoral components were associated with improved pain scores. At six months, the use of IDI compared to non-navigated TKA, and patellar resurfacing showed both improved OKS and pain scores.
Collapse
Affiliation(s)
- Jan Peter Van Meirhaeghe
- Sydney Orthopaedic Trauma and Reconstructive Surgery (SOTRS), Sydney, Australia
- Department of Orthopaedics, University Hospital of Ghent, Ghent, Belgium
| | - Ian A. Harris
- School of Clinical Medicine, Faculty of Medicine and Health, UNSW Sydney, Australia
| | - Alana Cuthbert
- South Australian Health & Medical Research Institute (SAHMRI), Australia
| | - Michelle Lorimer
- South Australian Health & Medical Research Institute (SAHMRI), Australia
| | - Michael McAuliffe
- Australian Orthopaedic Association National Joint Replacement Registry (AOANJRR), Australia
- Queensland University of Technology (QUT - Gardens Point), Australia
| | - Sam Adie
- St. George and Sutherland Hospitals, Sydney, Australia
- St. George and Sutherland Clinical School, UNSW, Australia
| | - Robert Molnar
- St. George and Sutherland Hospitals, Sydney, Australia
- St. George and Sutherland Clinical School, UNSW, Australia
| |
Collapse
|
2
|
Valič M, Milošev I, Levašič V, Blas M, Podovšovnik E, Koren J, Trebše R. Linear and Volumetric Polyethylene Wear Patterns after Primary Cruciate-Retaining Total Knee Arthroplasty Failure: An Analysis Using Optical Scanning and Computer-Aided Design Models. MATERIALS (BASEL, SWITZERLAND) 2024; 17:5007. [PMID: 39459713 PMCID: PMC11509131 DOI: 10.3390/ma17205007] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Subscribe] [Scholar Register] [Received: 09/13/2024] [Revised: 10/04/2024] [Accepted: 10/11/2024] [Indexed: 10/28/2024]
Abstract
(1) Background: Analyses of retrieved inserts allow for a better understanding of TKA failure mechanisms and the detection of factors that cause increased wear. The purpose of this implant retrieval study was to identify whether insert volumetric wear significantly differs among groups of common causes of total knee arthroplasty failure, whether there is a characteristic wear distribution pattern for a common cause of failure, and whether nominal insert size and component size ratio (femur-to-insert) influence linear and volumetric wear rates. (2) Methods: We digitally reconstructed 59 retrieved single-model cruciate-retaining inserts and computed their articular load-bearing surface wear utilizing an optical scanner and computer-aided design models as references. After comprehensively reviewing all cases, each was categorized into one or more of the following groups: prosthetic joint infection, osteolysis, clinical loosening of the component, joint malalignment or component malposition, instability, and other isolated causes. The associations between volumetric wear and causes of failure were estimated using a multiple linear regression model adjusted for time in situ. Insert linear penetration wear maps from the respective groups of failure were further processed and merged to create a single average binary image, highlighting a potential wear distribution pattern. The differences in wear rates according to nominal insert size (small vs. medium vs. large) and component size ratio (≤1 vs. >1) were tested using the Kruskal-Wallis test and the Mann-Whitney test, respectively. (3) Results: Patients with identified osteolysis alone and those also with clinical loosening of the component had significantly higher volumetric wear when compared to those without both causes (p = 0.016 and p = 0.009, respectively). All other causes were not significantly associated with volumetric wear. The instability group differentiated from the others with a combined peripheral antero-posterior wear distribution. Linear and volumetric wear rates showed no significant differences when compared by nominal insert size (small vs. medium vs. large, p = 0.563 and p = 0.747, respectively) or by component (femoral-to-insert) size ratio (≤1 vs. >1, p = 0.885 and p = 0.055, respectively). (4) Conclusions: The study found increased volumetric wear in cases of osteolysis alone, with greater wear when combined with clinical loosening compared to other groups. The instability group demonstrated a characteristic peripheral anterior and posterior wear pattern. Insert size and component size ratio seem not to influence wear rates.
Collapse
Affiliation(s)
- Matej Valič
- Valdoltra Orthopaedic Hospital, Jadranska cesta 31, 6280 Ankaran, Slovenia; (I.M.); (V.L.); (M.B.); (E.P.); (R.T.)
- Faculty of Medicine, University of Ljubljana, Vrazov trg 2, 1000 Ljubljana, Slovenia
| | - Ingrid Milošev
- Valdoltra Orthopaedic Hospital, Jadranska cesta 31, 6280 Ankaran, Slovenia; (I.M.); (V.L.); (M.B.); (E.P.); (R.T.)
- Jožef Stefan Institute, Jamova cesta 39, 1000 Ljubljana, Slovenia
| | - Vesna Levašič
- Valdoltra Orthopaedic Hospital, Jadranska cesta 31, 6280 Ankaran, Slovenia; (I.M.); (V.L.); (M.B.); (E.P.); (R.T.)
| | - Mateja Blas
- Valdoltra Orthopaedic Hospital, Jadranska cesta 31, 6280 Ankaran, Slovenia; (I.M.); (V.L.); (M.B.); (E.P.); (R.T.)
| | - Eva Podovšovnik
- Valdoltra Orthopaedic Hospital, Jadranska cesta 31, 6280 Ankaran, Slovenia; (I.M.); (V.L.); (M.B.); (E.P.); (R.T.)
- Faculty of Tourism Studies-Turistica, University of Primorska, Obala 11a, 6320 Portorož, Slovenia
| | - Jaka Koren
- Faculty of Electrical Engineering, University of Ljubljana, Tržaška cesta 25, 1000 Ljubljana, Slovenia;
| | - Rihard Trebše
- Valdoltra Orthopaedic Hospital, Jadranska cesta 31, 6280 Ankaran, Slovenia; (I.M.); (V.L.); (M.B.); (E.P.); (R.T.)
- Faculty of Medicine, University of Ljubljana, Vrazov trg 2, 1000 Ljubljana, Slovenia
| |
Collapse
|
3
|
de Ridder R, Kaptein BL, Pijls BG, Nelissen RGHH, Kaptijn HH. Five-year migration of uncemented femoral components in total knee arthroplasty with either highly cross-linked or conventional polyethylene inserts: a blinded randomized controlled trial using radiostereometric analysis. Bone Joint J 2024; 106-B:826-833. [PMID: 39084638 DOI: 10.1302/0301-620x.106b8.bjj-2023-1429.r1] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 08/02/2024]
Abstract
Aims The aim of this study was to compare the migration of the femoral component, five years postoperatively, between patients with a highly cross-linked polyethylene (HXLPE) insert and those with a conventional polyethylene (PE) insert in an uncemented Triathlon fixed insert cruciate-retaining total knee arthroplasty (TKA). Secondary aims included clinical outcomes and patient-reported outcome measures (PROMs). We have previously reported the migration and outcome of the tibial components in these patients. Methods A double-blinded randomized controlled trial was conducted including 96 TKAs. The migration of the femoral component was measured with radiostereometry (RSA) at three and six months and one, two, and five years postoperatively. PROMs were collected preoperatively and at all periods of follow-up. Results There was no clinically relevant difference in terms of migration of the femoral component or PROMs between the HXLPE and PE groups. The mean difference in migration (maximum total point motion), five years postopeatively, was 0.04 mm (95% CI -0.06 to 0.16) in favour of the PE group. Conclusion There was no clinically relevant difference in migration of the femoral component, for up to five years between the two groups. These findings will help to establish a benchmark for future studies on migration of femoral components in TKA.
Collapse
Affiliation(s)
- Ruud de Ridder
- Department of Orthopaedics, Lange Land Hospital Zoetermeer, Zoetermeer, Netherlands
- Reinier Haga Orthopaedic Centre, Zoetermeer, Netherlands
- Department of Orthopaedics, Leiden University Medical Centre, Leiden, Netherlands
| | - Bart L Kaptein
- Department of Orthopaedics, Leiden University Medical Centre, Leiden, Netherlands
| | - Bart G Pijls
- Department of Orthopaedics, Leiden University Medical Centre, Leiden, Netherlands
| | - Rob G H H Nelissen
- Department of Orthopaedics, Leiden University Medical Centre, Leiden, Netherlands
| | - Herman H Kaptijn
- Department of Orthopaedics, Lange Land Hospital Zoetermeer, Zoetermeer, Netherlands
- Reinier Haga Orthopaedic Centre, Zoetermeer, Netherlands
| |
Collapse
|
4
|
Bistolfi A, Spezia M, Cipolla A, Bonera M, Mellano D, Banci L, Colombo M, Massè A. Vitamin E-stabilized polyethylene shows similar survival rates at minimum 7-year follow-up compared to conventional polyethylene in primary total knee arthroplasty. J Exp Orthop 2024; 11:e12106. [PMID: 39239569 PMCID: PMC11375329 DOI: 10.1002/jeo2.12106] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 05/27/2024] [Revised: 06/20/2024] [Accepted: 07/01/2024] [Indexed: 09/07/2024] Open
Abstract
Purpose The aim of this cross-sectional study was to compare survival, clinical and radiographic results of total knee arthroplasty (TKA) with vitamin E-stabilized polyethylene (VEPE) or conventional polyethylene (CPE) at a minimum of 7-year follow-up. Methods Patients who underwent primary TKA between 2011 and 2015, receiving the same cemented rotating platform knee design with VEPE or CPE tibial inserts, were identified. Patients were contacted for clinical and radiographic follow-up. American Knee Society Score (KSS), Forgotten Joint Score (FJS-12), presence of periprosthetic radiolucent lines (RLLs) and osteolysis were evaluated at the last follow-up. Any revision, reintervention or other complications were recorded. Results Among 350 TKAs initially identified, 102 VEPE and 97 CPE knees were included for analysis with mean follow-up of 8.5 and 8.3 years, respectively. No significant difference was found in survival rates at 10-year follow-up with revision due to aseptic loosening (95.0% vs. 97.8%, p = 0.29) or due to any reason (87.6% vs. 89.6%, p = 0.78) between VEPE and CPE TKA. KSS function score resulted significantly higher in the VEPE group over CPE (77 vs. 63, p = 0.01). RLLs were more frequent in VEPE than CPE (54% vs. 32%, p = 0.05), mainly noticed medially and posteriorly beneath the tibial plate, adjacent to the trochlear shield and the posterior condyles. Osteolysis was observed in one knee per group, but patients were asymptomatic with stable implants. Conclusion TKA with VEPE and CPE tibial inserts showed comparable survival rates, complications and clinical and radiographic results up to 10-year follow-up. Level of Evidence Level III.
Collapse
Affiliation(s)
| | - Marco Spezia
- Centro Ortopedico Quadrante Hospital Omegna Italy
| | | | | | | | - Lorenzo Banci
- Clinical Research Department Permedica Orthopaedics Merate Italy
| | - Marta Colombo
- Clinical Research Department Permedica Orthopaedics Merate Italy
| | - Alessandro Massè
- University of the Studies of Turin Turin Italy
- Department of Orthopaedics and Traumatology CTO AOU Città della Salute e della Scienza di Torino Turin Italy
| |
Collapse
|
5
|
Bara A, Singh A, Patel K, Herlekar D. Extensive Metallosis in a Primary Knee Arthroplasty as a Result of Polyethylene Wear: Is It Avoidable? Cureus 2024; 16:e57888. [PMID: 38725739 PMCID: PMC11081404 DOI: 10.7759/cureus.57888] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Accepted: 04/08/2024] [Indexed: 05/12/2024] Open
Abstract
Metallosis is known to occur in metal-on-metal arthroplasty and has been of concern to orthopaedic surgeons worldwide. It is a rare, late complication of total knee arthroplasty (TKA), in which metal-on-metal contact leads to metal debris deposition in the surrounding tissue. Reasons for metal-on-metal contact could range from wear of the polyethylene insert to abnormal joint biomechanics. Many components can affect the development of metallosis, with polyethylene wear being the most common cause of metallosis. This paper discusses the case of an 85-year-old man who developed metallosis, attributed to polyethylene wear, 24 years after undergoing TKA. It also highlights the different components of knee prostheses, evaluates the efficacy of different types of polyethylene, and explores whether ceramic coating can improve TKA outcomes and reduce complications such as metallosis.
Collapse
Affiliation(s)
- Anas Bara
- Orthopaedics and Trauma, University of Central Lancashire, Preston, GBR
| | - Abhimanyu Singh
- Orthopaedics and Trauma, Royal Lancaster Infirmary, Lancaster, GBR
| | - Kuntal Patel
- Orthopaedics and Trauma, Royal Lancaster Infirmary, Lancaster, GBR
| | - Deepak Herlekar
- Orthopaedics and Trauma, Royal Lancaster Infirmary, Lancaster, GBR
| |
Collapse
|
6
|
Migliorini F, Vecchio G, Eschweiler J, Schneider SM, Hildebrand F, Maffulli N. Reduced knee laxity and failure rate following anterior cruciate ligament reconstruction compared with repair for acute tears: a meta-analysis. J Orthop Traumatol 2023; 24:8. [PMID: 36805839 PMCID: PMC9941413 DOI: 10.1186/s10195-023-00688-5] [Citation(s) in RCA: 2] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Figures] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 08/25/2022] [Accepted: 02/04/2023] [Indexed: 02/22/2023] Open
Abstract
BACKGROUND Following anterior cruciate ligament (ACL) tears, both repair and reconstruction may be performed to restore joint biomechanics and proprioception. The present study compared joint laxity, patient-reported outcome measures (PROMs), and rate of failure following primary repair versus reconstruction for ACL ruptures. METHODS This meta-analysis followed the Preferred Reporting Items for Systematic Reviews and Meta-Analyses guidelines. Pubmed, Google scholar, Embase, and Web of Science were accessed in September 2022. All the clinical investigations comparing repair versus reconstruction for primary ACL tears were accessed. Studies reporting data on multiple ligament injuries settings were not eligible. RESULTS Data from eight articles (708 procedures) were collected. The mean length of the follow-up was 67.3 ± 119.4 months. The mean age of the patients was 27.1 ± 5.7 years. Thirty-six percent (255 of 708 patients) were women. The mean body mass index (BMI) was 24.3 ± 1.1 kg/m2. The mean time span from injury to surgery was 36.2 ± 32.3 months. There was comparability at baseline with regards to instrumental laxity, Lachman test, International Knee Document Committee (IKDC), and Tegner Scale (P > 0.1). Similarity between ACL reconstruction and repair was found in IKDC (P = 0.2) and visual analog scale (VAS) satisfaction (P = 0.7). The repair group demonstrated greater mean laxity (P = 0.0005) and greater rate of failure (P = 0.004). CONCLUSION ACL reconstruction may yield greater joint stability and lower rate of failure compared with surgical repair. Similarity was found in PROMs. LEVEL OF EVIDENCE III.
Collapse
Affiliation(s)
- Filippo Migliorini
- Department of Orthopaedic, Trauma, and Reconstructive Surgery, RWTH University Hospital, Pauwelsstraße 31, 52074, Aachen, Germany. .,Department of Orthopaedic and Trauma Surgery, Eifelklinik St. Brigida, 52152, Simmerath, Germany.
| | - Gianluca Vecchio
- grid.11780.3f0000 0004 1937 0335Department of Medicine, Surgery and Dentistry, University of Salerno, Via S. Allende, 84081 Baronissi, SA Italy
| | - Jörg Eschweiler
- grid.412301.50000 0000 8653 1507Department of Orthopaedic, Trauma, and Reconstructive Surgery, RWTH University Hospital, Pauwelsstraße 31, 52074 Aachen, Germany
| | - Sarah-Marie Schneider
- grid.412301.50000 0000 8653 1507Department of Orthopaedic, Trauma, and Reconstructive Surgery, RWTH University Hospital, Pauwelsstraße 31, 52074 Aachen, Germany
| | - Frank Hildebrand
- grid.412301.50000 0000 8653 1507Department of Orthopaedic, Trauma, and Reconstructive Surgery, RWTH University Hospital, Pauwelsstraße 31, 52074 Aachen, Germany
| | - Nicola Maffulli
- grid.11780.3f0000 0004 1937 0335Department of Medicine, Surgery and Dentistry, University of Salerno, Via S. Allende, 84081 Baronissi, SA Italy ,grid.9757.c0000 0004 0415 6205School of Pharmacy and Bioengineering, Faculty of Medicine, Keele University, Thornburrow Drive, Stoke On Trent, England ,grid.4868.20000 0001 2171 1133Barts and the London School of Medicine and Dentistry, Centre for Sports and Exercise Medicine, Mile End Hospital, Queen Mary University of London, 275 Bancroft Road, London, E1 4DG England
| |
Collapse
|
7
|
Puijk R, Puijk RH, Laende EK, Dunbar MJ, Plevier JWM, Nolte PA, Pijls BGCW. 6-month migration sufficient for evaluation of total knee replacements: a systematic review and meta-analysis. Acta Orthop 2023; 94:577-587. [PMID: 38038237 PMCID: PMC10690979 DOI: 10.2340/17453674.2023.24579] [Citation(s) in RCA: 7] [Impact Index Per Article: 3.5] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 04/22/2023] [Accepted: 10/22/2023] [Indexed: 12/02/2023] Open
Abstract
BACKGROUND AND PURPOSE This updated meta-analysis evaluates the migration pattern of the tibial component of primary total knee replacements measured with radiostereometric analysis (RSA). We aimed to evaluate whether 6-month maximum total point motion (MTPM) values could be used instead of 1-year MTPM for RSA threshold testing and to present the pooled migration patterns for different implant designs that can be used as a benchmark. PATIENTS AND METHODS The search included all published RSA studies on migration patterns of tibial components until 2023. Study groups were classified according to their prosthesis brand, fixation, and insert (PFI). Sub-analyses were performed to compare the mean tibial component migration patterns of different implant variables, stratified according to fixation. RESULTS 96 studies (43 new studies), including 197 study groups and 4,706 knees, were included. Most migration occurred within the first 6 postoperative months (126 study groups: mean 0.58 mm, 95% confidence interval [CI] 0.50-0.65), followed by minimal migration between 6 and 12 months (197 study groups: mean 0.04 mm, CI 0.03-0.06), irrespective of the fixation method used. Distinct migration patterns were observed among the different fixation methods. No differences were found in migration patterns among cemented components in any of the sub-group analyses conducted. For uncemented implants, trabecular metal surfaced components seemed to migrate less than porous-coated or uncoated components Conclusion: Based on the small difference between MTPM values at 6 months and 1 year, MTPM at 6 months could be used instead of MTPM at 1 year for RSA threshold testing. The pooled migration patterns can be used as benchmark for evaluation of new implants by defining fixation-specific RSA thresholds when combined with implant survival.
Collapse
Affiliation(s)
- Raymond Puijk
- Department of Orthopaedics, Spaarne Gasthuis, Hoofddorp, the Netherlands.
| | - Rowan H Puijk
- Department of Orthopaedics, Spaarne Gasthuis, Hoofddorp, the Netherlands
| | - Elise K Laende
- Mechanical and Materials Engineering, Queen's University, Kingston, Ontario, Canada; Division of Orthopaedics, Department of Surgery, Dalhousie University and QEII Health Sciences Centre, Nova Scotia Health Authority, Halifax, Nova Scotia, Canada
| | - Michael J Dunbar
- Division of Orthopaedics, Department of Surgery, Dalhousie University and QEII Health Sciences Centre, Nova Scotia Health Authority, Halifax, Nova Scotia, Canada; School of Biomedical Engineering, Dalhousie University, Halifax, Nova Scotia, Canada
| | - José W M Plevier
- Walaeus Library, Leiden University Medical Center, Leiden, The Netherlands
| | - Peter A Nolte
- Department of Orthopaedics, Spaarne Gasthuis, Hoofddorp, the Netherlands; Department of Oral Cell Biology, Academic Centre for Dentistry (ACTA), University of Amsterdam and Vrije Universiteit Amsterdam, Amsterdam, the Netherlands
| | - Bart G C W Pijls
- Department of Orthopaedics, Leiden University Medical Center, Leiden, The Netherlands
| |
Collapse
|
8
|
Risitano S, Cacciola G, Capella M, Bosco F, Giustra F, Fusini F, Indelli PF, Massé A, Sabatini L. Comparison between gaits after a medial pivot and posterior stabilized primary total knee arthroplasty: a systematic review of the literature. ARTHROPLASTY 2023; 5:15. [PMID: 36927464 PMCID: PMC10022170 DOI: 10.1186/s42836-023-00165-8] [Citation(s) in RCA: 5] [Impact Index Per Article: 2.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/09/2022] [Accepted: 01/16/2023] [Indexed: 03/18/2023] Open
Abstract
BACKGROUND Total knee arthroplasty (TKA) is one of the most performed orthopedic procedures worldwide. While excellent efficacy has been reported, about 20% of patients are not satisfied with the result. A potential cause is the problematic reproduction of knee kinematics. This systematic review examines gait analysis studies in primary medial pivot (MP) and posterior stabilized (PS) TKAs to investigate the differences between the two prosthesis designs. METHODS A systematic review was conducted by following PRISMA guidelines. Five databases (PubMed, Medline, Embase, Scopus and the Cochrane Database of Systematic Reviews) were analyzed, and eligible articles were evaluated in terms of the levels of evidence. The methodological quality of the articles was assessed by using the MINORS scoring. This review was registered in PROSPERO. RESULTS Nine studies were included. Gait analysis was performed in 197 MP TKA and 192 PS TKA patients. PS TKA cases showed (P < 0.05) a significantly higher peak of knee flexion angle during the swing phase, greater knee flexion angle at toe-off, an increased knee adduction angle, higher knee flexion and extension moment, increased anterior femoral roll during knee flexion and anterior translation on medial and lateral condyle during knee flexion compared to MP TKA. MP TKA showed statistically significant (P < 0.05) higher knee rotational moment and greater tibiofemoral external rotation motion during knee flexion than PS TKA. No statistically significant difference (P > 0.05) was reported regarding gait spatial-temporal parameters. The Forgotten Joint Score (FJS) and Western Ontario and McMaster Universities Comparison in terms of Arthritis Index (WOMAC) score (mean stiffness) showed that MP TKA yielded significantly better results than PS TKA. CONCLUSIONS This systematic review revealed significant kinematic and kinetic differences between MP and PS TKA at all gait analysis phases. Furthermore, the considerable difference between TKA design and the kinematics of healthy knee were highlighted in this study. LEVEL OF EVIDENCE III.
Collapse
Affiliation(s)
- Salvatore Risitano
- Department of Orthopaedic Surgery and Traumatology, University of Turin, 10126, Turin, Italy.
- Department of Orthopaedic Surgery and Traumatology, CTO Hospital of Turin, Città Della Salute E Della Scienza, 10126, Turin, Italy.
| | - Giorgio Cacciola
- Department of Orthopaedic Surgery and Traumatology, University of Turin, 10126, Turin, Italy
| | - Marcello Capella
- Department of Orthopaedic Surgery and Traumatology, University of Turin, 10126, Turin, Italy
- Department of Orthopaedic Surgery and Traumatology, CTO Hospital of Turin, Città Della Salute E Della Scienza, 10126, Turin, Italy
| | - Francesco Bosco
- Department of Orthopaedic Surgery and Traumatology, University of Turin, 10126, Turin, Italy
- Department of Orthopaedics and Traumatology, Ospedale San Giovanni Bosco-ASL Città di Torino, Piazza del Donatore Di Sangue, 3, 10154, Turin, Italy
| | - Fortunato Giustra
- Department of Orthopaedic Surgery and Traumatology, University of Turin, 10126, Turin, Italy
- Department of Orthopaedics and Traumatology, Ospedale San Giovanni Bosco-ASL Città di Torino, Piazza del Donatore Di Sangue, 3, 10154, Turin, Italy
| | - Federico Fusini
- Department of Orthopaedic Surgery, Regina Montis Regalis Hospital, 12084, MondovìCuneo, Italy
| | - Pier Francesco Indelli
- Department of Orthopaedic Surgery and Bioengineering, Stanford University School of Medicine, Palo Alto Veterans Affairs Health Care System (PAVAHCS), Palo Alto, CA, 94304, USA
| | - Alessandro Massé
- Department of Orthopaedic Surgery and Traumatology, University of Turin, 10126, Turin, Italy
- Department of Orthopaedic Surgery and Traumatology, CTO Hospital of Turin, Città Della Salute E Della Scienza, 10126, Turin, Italy
| | - Luigi Sabatini
- Department of Orthopaedic Surgery and Traumatology, University of Turin, 10126, Turin, Italy
- Department of Orthopaedic Surgery and Traumatology, CTO Hospital of Turin, Città Della Salute E Della Scienza, 10126, Turin, Italy
| |
Collapse
|
9
|
Hasegawa M, Tone S, Naito Y, Sudo A. Ultra-High-Molecular-Weight Polyethylene in Hip and Knee Arthroplasties. MATERIALS (BASEL, SWITZERLAND) 2023; 16:2140. [PMID: 36984020 PMCID: PMC10054334 DOI: 10.3390/ma16062140] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Figures] [Subscribe] [Scholar Register] [Received: 02/12/2023] [Revised: 03/05/2023] [Accepted: 03/06/2023] [Indexed: 06/18/2023]
Abstract
Ultra-high-molecular-weight polyethylene (UHMWPE) wear and particle-induced osteolysis contribute to the failure of total hip arthroplasty (THA) and total knee arthroplasty (TKA). Highly crosslinked polyethylene (HXLPE) was developed in the late 1990s to reduce wear and has shown lower wear rates and loosening than conventional UHMWPE in THA. The irradiation dose for crosslinking is up to 100 kGy. However, during crosslinking, free radical formation induces oxidation. Using HXLPE in THA, the cumulative revision rate was determined to be significantly lower (6.2%) than that with conventional UHMWPE (11.7%) at a mean follow-up of 16 years, according to the Australian Orthopaedic Association National Joint Replacement Registry. However, HXLPE does not confer to TKA the same advantages it confers to THA. Several alternatives have been developed to prevent the release of free radicals and improve polymer mechanical properties, such as thermal treatment, phospholipid polymer 2-methacryloyloxyethyl phosphorylcholine grafting, remelting, and vitamin E addition. Among these options, vitamin E addition has reported good clinical results and wear resistance similar to that of HXLPE without vitamin E, as shown by short-term clinical studies of THA and TKA. This review aims to provide a comprehensive overview of the development and performance of UHMWPE in THA and TKA.
Collapse
|
10
|
Giustra F, Bistolfi A, Bosco F, Fresia N, Sabatini L, Berchialla P, Sciannameo V, Massè A. Highly cross-linked polyethylene versus conventional polyethylene in primary total knee arthroplasty: comparable clinical and radiological results at a 10-year follow-up. Knee Surg Sports Traumatol Arthrosc 2023; 31:1082-1088. [PMID: 36409325 PMCID: PMC9958150 DOI: 10.1007/s00167-022-07226-6] [Citation(s) in RCA: 13] [Impact Index Per Article: 6.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Figures] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 08/20/2022] [Accepted: 11/06/2022] [Indexed: 11/22/2022]
Abstract
PURPOSE Highly crosslinked polyethylene (HXLPE) was introduced in total knee arthroplasty (TKA) to reduce wear and consequent revisions for loosening due to conventional polyethylene (CPE) wear. This study aims to analyse whether HXLPE is as safe as CPE and could improve the TKA clinical and radiological results in a long-term follow-up. METHODS This retrospective study included all consecutive starting series of 223 patients with severe primary knee osteoarthritis (OA), with a minimum follow-up of 10 years treated between July 1st, 2007, and July 31st, 2010. After excluding patients who did not respect the inclusion and exclusion criteria, 128 patients were included in the analysis of this study. The patients were then divided into two groups according to the type of polyethylene (PE) implanted: CPE or HXLPE liners. All patients were evaluated for clinical and radiological parameters, causes and revision rates related to the type of PE implanted. RESULTS HXLPE appears to be as safe as CPE in TKA, reporting no higher revisions for osteolysis, prosthesis loosening, infection, and mechanical failure. Nevertheless, no statistically significant differences were found between the two groups in the clinical and radiological outcomes evaluated. CONCLUSIONS Clinical, radiological results, and revision rates are similar between HXLPE and CPE in TKA after 10 years of follow-up, although HXLPE benefits remain controversial. LEVEL OF EVIDENCE III.
Collapse
Affiliation(s)
- Fortunato Giustra
- Department of Orthopaedics and Traumatology, University of Turin, CTO, Via Zuretti 29, 10126 Turin, Italy
| | - Alessandro Bistolfi
- Orthopaedics and Traumatology, Ospedale Cardinal Massaia Asti, Via Conte Verde 125, 14100 Asti, Italy
| | - Francesco Bosco
- Department of Orthopaedics and Traumatology, University of Turin, CTO, Via Zuretti 29, 10126, Turin, Italy.
| | - Nicolò Fresia
- Department of Orthopaedics and Traumatology, University of Turin, CTO, Via Zuretti 29, 10126 Turin, Italy
| | - Luigi Sabatini
- Department of Orthopaedics and Traumatology, University of Turin, CTO, Via Zuretti 29, 10126 Turin, Italy
| | - Paola Berchialla
- Department of Clinical and Biological Sciences, University of Turin, Turin, Italy
| | - Veronica Sciannameo
- Department of Clinical and Biological Sciences, University of Turin, Turin, Italy
| | - Alessandro Massè
- Department of Orthopaedics and Traumatology, University of Turin, CTO, Via Zuretti 29, 10126 Turin, Italy
| |
Collapse
|
11
|
Wyatt P, Satalich J, Gorica Z, O'Neill C, Cyrus J, Vap A, O'Connell R. Tibial Derotational Osteotomy for Patellofemoral Instability: A Systematic Review. Adv Orthop 2022; 2022:8672113. [PMID: 36620474 PMCID: PMC9812606 DOI: 10.1155/2022/8672113] [Citation(s) in RCA: 3] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Figures] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 09/14/2022] [Revised: 11/15/2022] [Accepted: 12/14/2022] [Indexed: 12/29/2022] Open
Abstract
Introduction The etiology of patellofemoral (PF) instability is multifactorial. Excessive external tibial torsion has been associated with recurrent patellar subluxation and persistent anterior knee pain. Several surgical techniques have been historically used to correct this, including medial patellofemoral ligament reconstruction, tibial tuberosity transfer (TTT), trochleoplasty, and tibial derotation osteotomy (TDO). The purpose of this systematic review is to investigate the safety and efficacy of TDO for PF instability and pain. Methods A thorough search of the literature was conducted on July 15, 2022. Seven studies met the inclusion criteria for this systematic review. Results Among the included studies, there were 179 total subjects and 204 operative knees. Mean follow-up time was 66.31 months (range 11-192). Complication rate was low (12.8%) in studies that reported complications. Average degree of anatomical correction in the transverse plane was 19.9 degrees with TDO. This increased to 34 degrees when combined with TTT. All PROMs assessed were significantly increased postoperatively (p < 0.05). Age greater than 25 years and advanced PF chondromalacia may negatively affect postoperative outcomes. Conclusion The primary findings of this review were as follows: (1) TDO results in significantly improved pain and PROM ratings in patients with PF pain and/or instability, (2) the likelihood of complication, including recurrent patella subluxation after TDO, is low but may be increased by aging, and (3) the successful anatomical correction of TDO may be augmented by concurrent TTT in some cases.
Collapse
Affiliation(s)
- Phillip Wyatt
- Virginia Commonwealth University School of Medicine, Richmond, VA, USA
| | - James Satalich
- Virginia Commonwealth University School of Medicine, Richmond, VA, USA
| | - Zylyftar Gorica
- Virginia Commonwealth University School of Medicine, Richmond, VA, USA
| | - Conor O'Neill
- Virginia Commonwealth University School of Medicine, Richmond, VA, USA
| | - John Cyrus
- Virginia Commonwealth University School of Medicine, Richmond, VA, USA
| | - Alexander Vap
- Virginia Commonwealth University School of Medicine, Richmond, VA, USA
| | - Robert O'Connell
- Virginia Commonwealth University School of Medicine, Richmond, VA, USA
| |
Collapse
|
12
|
No Significant Differences in Clinical and Radiographic Outcomes between PCL Retained or Sacrificed Kinematic Aligned Medial Pivot Total Knee Arthroplasty in Varus Knee. J Clin Med 2022; 11:jcm11216569. [PMID: 36362796 PMCID: PMC9658241 DOI: 10.3390/jcm11216569] [Citation(s) in RCA: 18] [Impact Index Per Article: 6.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/30/2022] [Revised: 10/29/2022] [Accepted: 11/02/2022] [Indexed: 11/09/2022] Open
Abstract
In the last decades, several surgical techniques, such as medial pivot (MP) philosophy and kinematic alignment (KA), have been introduced in total knee arthroplasty (TKA) to improve patients’ outcomes. This retrospective study aims to evaluate the clinical, radiographic, and functional results of PCL preservation or sacrifice in KA MP-TKA. A consecutive series of 147 patients older than 60, with a minimum follow-up of two years, were treated with TKA for severe primary knee osteoarthritis (OA) at the Department of Orthopedics and Traumatology between 1 January 2019, and 1 July 2020. After excluding those not meeting the inclusion criteria, 64 patients were included in the study analysis. Regarding radiographic outcomes, no statistically significant difference was observed between patients with preserved or sacrificed PCL (p > 0.05). A slight improvement in Knee Society Score (KSS), knee and function score, and FJS was observed for the PCL-preserved group, although this superiority tendency was not statistically significant (p > 0.05). PCL-preserved MA MP-TKA reported a statistically significant result in only two questions on the FJS questionnaire (p < 0.05). A slight, non-statistically significant improvement in active ROM was found in the PCL-sacrificed group (p > 0.05). No interventions or revisions were reported in this case series for all treated patients at the final follow-up. No significant differences were described in clinical, radiographic, and functional outcomes in preserved or sacrificed PCL KA MP-TKA. Although not significant, a slight trend toward better clinical outcomes was reported in PCL-preserved KA MP-TKA.
Collapse
|
13
|
Mullaji AB, Khalifa AA. Is it prime time for robotic-assisted TKAs? A systematic review of current studies. J Orthop 2022; 34:31-39. [PMID: 35992614 PMCID: PMC9389136 DOI: 10.1016/j.jor.2022.07.016] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 05/30/2022] [Revised: 06/25/2022] [Accepted: 07/23/2022] [Indexed: 12/13/2022] Open
Abstract
INTRODUCTION Less-than-optimum positioning of femoral and tibial components and improper soft tissue tension, with abnormal loads and reduced range of motion, may cause lower patient satisfaction rates. To reduce surgeon-related variables during TKA, technology-assisted TKA was introduced, including computer navigation and robotic-assisted surgery (RATKA). Although several studies show promising short- and long-term functional and radiological outcomes of RATKA, there are still concerns related to its absolute superiority over conventional TKA. METHODS This review aims to provide an updated insight into the most recent articles reporting on outcomes (functional, radiological, and complications) of RATKA through a systematic search of major databases. A comprehensive English literature search was performed by both authors through four databases (Embase, PubMed, Web of Science, and Scopus). The full text of the final eligible studies was evaluated for inclusion, resulting in 13 studies that are included in this review. RESULTS There were 2112 knees in the 13 studies, with a follow-up ranging from three months to 13 years; only three were randomized controlled trials (RCTs), and nine directly compared the results of RATKA with CTKA technique. Seven studies reported the operative time ranging from 76.8 to 156 min; six reported a longer operative time with RATKA. Length of hospital stay (LOS) was reported in six studies which ranged from 0.48 to 2.1 days; in four studies the LOS was shorter with RATKA. In seven of the nine studies comparing RATKA with CTKA, no difference in functional outcomes was found. Four out of six studies reported that the overall alignment had mechanical alignment within ±3° of neutral alignment in all RATKA patients with an HKA ranging from -0.3 to 1.8°. Only one study reported better radiological outcomes in the RATKA group. In six comparative studies, no difference was found in the incidence of complications between RATKA and CTKA. CONCLUSION Although robotic-assisted total knee arthroplasty is a promising technology that provides better component alignment and superior early functional outcomes, the justification for its widespread adoption needs more robust evidence through well-designed and better long-term studies demonstrating superior, predictable, and durable clinical results compared to conventional total knee arthroplasty techniques.
Collapse
Affiliation(s)
| | - Ahmed A. Khalifa
- Orthopaedic Department, Qena Faculty of Medicine and University Hospital, South Valley University, Qena, Egypt
| |
Collapse
|
14
|
Bosco F, Giustra F, Giai Via R, Lavia AD, Capella M, Sabatini L, Risitano S, Cacciola G, Vezza D, Massè A. Could anterior closed-wedge high tibial osteotomy be a viable option in patients with high posterior tibial slope who undergo anterior cruciate ligament reconstruction? A systematic review and meta-analysis. EUROPEAN JOURNAL OF ORTHOPAEDIC SURGERY & TRAUMATOLOGY : ORTHOPEDIE TRAUMATOLOGIE 2022:10.1007/s00590-022-03419-4. [PMID: 36308547 PMCID: PMC10368555 DOI: 10.1007/s00590-022-03419-4] [Citation(s) in RCA: 32] [Impact Index Per Article: 10.7] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Subscribe] [Scholar Register] [Received: 09/28/2022] [Accepted: 10/18/2022] [Indexed: 05/16/2023]
Abstract
PURPOSE This study aims to examine the clinical and radiological outcomes of patients who underwent ACL reconstruction (ACLR) combined with anterior closed-wedge high tibial osteotomy (ACW-HTO) for posterior tibial slope (PTS) reduction to investigate the efficacy of this procedure in improving anterior knee stability and preventing graft failure in primary and revision ACLR. METHODS A literature search was conducted in six databases (PubMed, Embase, Medline, Web of Science, Cochrane, and Scopus). The study was performed according to the Preferred Reporting Items for Systematic Reviews and Meta-Analyses (PRISMA) guideline. The initial screening identified 1246 studies. Each eligible clinical article was screened according to the Oxford Centre for Evidence-Based Medicine 2011 levels of evidence (LoE), excluding clinical studies of LoE V. Quality assessment of the articles was performed using the ROBINS-I methodological evaluation. This systematic review and meta-analysis was registered on the International Prospective Register of Systematic Reviews (PROSPERO). For the outcomes that were possible to perform a meta-analysis, a p < 0.05 was considered statistically significant. RESULTS Five clinical studies were included in the final analysis. A total of 110 patients were examined. Pre- and post-operative clinical and objective tests that assess anteroposterior knee stability, PTS, clinical scores, and data on surgical characteristics, complications, return to sports activity, and graft failure after ACLR were investigated. A meta-analysis was conducted using R software, version 4.1.3 (2022, R Core Team), for Lysholm score and PTS outcomes. A statistically significant improvement for both these clinical and radiological outcomes (p < 0.05) after the ACW-HTO surgical procedure was found. CONCLUSION ACLR combined with ACW-HTO restores knee stability and function with satisfactory clinical and radiological outcomes in patients with an anterior cruciate ligament injury associated with a high PTS and seems to have a protective effect from further ruptures on the reconstructed ACL. LEVEL OF EVIDENCE Level IV.
Collapse
Affiliation(s)
- Francesco Bosco
- Department of Orthopaedics and Traumatology, University of Turin, CTO, Via Zuretti 29, 10126, Turin, Italy.
| | - Fortunato Giustra
- Department of Orthopaedics and Traumatology, University of Turin, CTO, Via Zuretti 29, 10126, Turin, Italy
| | - Riccardo Giai Via
- Department of Orthopaedics and Traumatology, University of Turin, CTO, Via Zuretti 29, 10126, Turin, Italy
| | | | - Marcello Capella
- Department of Orthopaedics and Traumatology, University of Turin, CTO, Via Zuretti 29, 10126, Turin, Italy
| | - Luigi Sabatini
- Department of Orthopaedics and Traumatology, University of Turin, CTO, Via Zuretti 29, 10126, Turin, Italy
| | - Salvatore Risitano
- Department of Orthopaedics and Traumatology, University of Turin, CTO, Via Zuretti 29, 10126, Turin, Italy
| | - Giorgio Cacciola
- Department of Orthopaedics and Traumatology, University of Turin, CTO, Via Zuretti 29, 10126, Turin, Italy
| | - Daniele Vezza
- Department of Orthopaedics and Traumatology, University of Turin, CTO, Via Zuretti 29, 10126, Turin, Italy
| | - Alessandro Massè
- Department of Orthopaedics and Traumatology, University of Turin, CTO, Via Zuretti 29, 10126, Turin, Italy
| |
Collapse
|
15
|
LEWIS PL, W-DAHL A, ROBERTSSON O, PRENTICE HA, GRAVES SE. Impact of patient and prosthesis characteristics on common reasons for total knee replacement revision: a registry study of 36,626 revision cases from Australia, Sweden, and USA. Acta Orthop 2022; 93:623-633. [PMID: 35819795 PMCID: PMC9275496 DOI: 10.2340/17453674.2022.3512] [Citation(s) in RCA: 7] [Impact Index Per Article: 2.3] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 04/14/2022] [Indexed: 01/31/2023] Open
Abstract
BACKGROUND AND PURPOSE Total knee replacement (TKR) studies usually analyze all-cause revision when considering relationships with patient and prosthesis factors. We studied how these factors impact different revision diagnoses. PATIENTS AND METHODS We used data from 2003 to 2019 of TKR for osteoarthritis from the arthroplasty registries of Sweden, Australia, and Kaiser Permanente, USA to study patient and prosthesis characteristics for specific revision diagnoses. There were 1,072,924 primary TKR included and 36,626 were revised. Factors studied included age, sex, prosthesis constraint, fixation method, bearing mobility, polyethylene type, and patellar component use. Revision diagnoses were arthrofibrosis, fracture, infection, instability, loosening, pain, patellar reasons, and wear. Odds ratios (ORs) for revision were estimated and summary effects were calculated using a meta-analytic approach. RESULTS We found between-registry consistency in 15 factor/reason analyses. Risk factors for revision for arthrofibrosis were age < 65 years (OR 2.0; 95% CI 1.4-2.7) and mobile bearing designs (MB) (OR 1.7; CI 1.1-2.5), for fracture were female sex (OR 3.2; CI 2.2-4.8), age ≥ 65 years (OR 2.8; CI 1.9-4) and posterior stabilized prostheses (PS) (OR 2.1; CI 1.3-3.5), for infection were male sex (OR 1.9; CI 1.7-2.0) and PS (OR 1.5; CI 1.2-1.8), for instability were age < 65 years (OR 1.5; CI 1.3-1.8) and MB (OR 1.5; CI 1.1-2.2), for loosening were PS (OR 1.5; CI 1.4-1.6), MB (OR 2.2; CI 1.6-3.0) and use of ultra-high molecular weight polyethylene (OR 2.3; CI 1.8-2.9), for patellar reasons were not resurfacing the patella (OR 13.6; CI 2.1-87.2) and MB (OR 2.0; CI 1.2-3.3) and for wear was cementless fixation (OR 4.9; CI 4.3-5.5). INTERPRETATION Patients could be counselled regarding specific age and sex risks. Use of minimally stabilized, fixed bearing, cemented prostheses, and patellar components is encouraged to minimize revision risk.
Collapse
Affiliation(s)
- Peter L LEWIS
- Australian Orthopaedic Association National Joint Replacement Registry, South Australian Health and Medical Research Institute, Adelaide, South Australia,Department of Orthopedics, Clinical Science Lund, Faculty of Medicine, Lund University, Lund, Sweden
| | - Annette W-DAHL
- Swedish Knee Arthroplasty Register, Lund, Sweden,Department of Orthopedics, Clinical Science Lund, Faculty of Medicine, Lund University, Lund, Sweden
| | - Otto ROBERTSSON
- Swedish Knee Arthroplasty Register, Lund, Sweden,Department of Orthopedics, Clinical Science Lund, Faculty of Medicine, Lund University, Lund, Sweden
| | | | - Stephen E GRAVES
- Australian Orthopaedic Association National Joint Replacement Registry, South Australian Health and Medical Research Institute, Adelaide, South Australia
| |
Collapse
|