Keyser LE, McKinney JL, Pulliam SJ, Weinstein MM. A digital health program for treatment of urinary incontinence: retrospective review of real-world user data.
Int Urogynecol J 2022. [PMID:
35969249 DOI:
10.1007/s00192-022-05321-3]
[Citation(s) in RCA: 2] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [What about the content of this article? (0)] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/11/2022] [Accepted: 07/21/2022] [Indexed: 10/15/2022]
Abstract
INTRODUCTION AND HYPOTHESIS
To determine the effectiveness of a prescription digital therapeutic (pDTx) in reducing urinary incontinence (UI) symptoms in real-world users.
METHODS
This is a retrospective cohort study of real-world data from users of a pDTx designed to guide pelvic floor muscle training(PFMT) between July 1, 2020-December 31, 2021. The primary outcome was UI symptom change as reported via in-app Urogenital Distress Inventory (UDI-6). Included subjects were female, ≥ 18 years with a diagnosis of stress, urgency, or mixed UI who completed the UDI-6 at baseline and 8 weeks. Demographic, symptom, and adherence data were summarized. Paired t-test and Wilcoxon signed rank test were used to analyze change in outcomes from baseline to 8 weeks across adherence and UI diagnosis groups.
RESULTS
Of 532 women with UI, 265 (50%) met criteria and were included in the analysis. Mean age was 51.2 ± 11.5 years (range 22-84, N = 265). Mean body mass index (BMI) was 27.3 ± 6.2 kg/m2 (range 15.2-46.9, N = 147). Most participants had stress UI (59%) followed by mixed UI (22%), urgency UI/OAB (11%), and unspecified UI (8%). UDI-6 scores improved by 13.90 ± 15.53 (p ≤ 0.001); 62% met or exceeded MCID. Device-reported PFMT adherence was 72% at 4 weeks and 66% at 8 weeks (100% = 14 uses/week). Participants in each diagnosis category reported significant improvement on UDI-6 score from baseline to 8 weeks. No association between UDI-6 score improvement and adherence category, age, BMI, or UI subtype was identified.
CONCLUSIONS
This study demonstrates effectiveness of a pDTx in reducing UI symptoms in a real-world setting. Users achieved statistically and clinically significant symptom improvement over an 8-week period.
Collapse