1
|
Hung MM, Elpa DP, Ochirov O, Urban PL. Critical Role of Voltage Application Points in "Analog" and "Digital" Electrospray Ionization Mass Spectrometry. JOURNAL OF THE AMERICAN SOCIETY FOR MASS SPECTROMETRY 2025; 36:1191-1199. [PMID: 40234243 PMCID: PMC12063163 DOI: 10.1021/jasms.5c00082] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Grants] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 03/16/2025] [Revised: 03/28/2025] [Accepted: 04/01/2025] [Indexed: 04/17/2025]
Abstract
In electrospray ionization (ESI) mass spectrometry (MS), an electric DC potential is often applied to a metal capillary used to infuse a liquid sample. However, in some cases, especially when employing nanoelectrospray ionization (nanoESI), it is convenient to use a nonconducting capillary for sample delivery and spraying. In these cases, the potentials can be applied, for example, using a metal union placed in the proximity of the capillary outlet or to an electrode located in the sample reservoir near the capillary inlet. The optimum potential values, which warrant high MS signals, are different in these two operational conditions. A higher potential needs to be applied when the electrode is placed further away from the capillary outlet. Moreover, sample conductivity has a strong influence on the optimum potential values. Lower potentials must be used with highly conductive electrolytes. Thus, DC voltage scans are required to determine the optimum potentials. Applying electric potential to the electrode located in the sample reservoir, rather than metal union, significantly decreases the appearance of oxidized analyte peaks. We also show that a single-polarity square AC waveform can be applied to the union or sample reservoir electrode, and if its frequency is sufficiently high, it has a similar effect as decreasing DC voltage, allowing for digital control of electrospray with square waves (by varying duty cycle). Interestingly, the liquid meniscus oscillation frequency is independent of the AC signal frequency if the frequency is sufficiently high. Applying the AC signal in certain conditions stabilizes the electrospray plume. These observations reveal the resemblance of the ESI sample line to an RC circuit.
Collapse
Affiliation(s)
- Min-Min Hung
- Department of Chemistry, National Tsing Hua University, 101, Section 2, Kuang-Fu Road, Hsinchu 300044, Taiwan
| | - Decibel P. Elpa
- Department of Chemistry, National Tsing Hua University, 101, Section 2, Kuang-Fu Road, Hsinchu 300044, Taiwan
| | - Ochir Ochirov
- Department of Chemistry, National Tsing Hua University, 101, Section 2, Kuang-Fu Road, Hsinchu 300044, Taiwan
| | - Pawel L. Urban
- Department of Chemistry, National Tsing Hua University, 101, Section 2, Kuang-Fu Road, Hsinchu 300044, Taiwan
| |
Collapse
|
2
|
Xu X, He G, Xu X, Wu Z, Cai T. Investigation of the electrochemical oxidation of 2,3′-bisindolylmethanes in positive-ion electrospray ionization mass spectrometry. RSC Adv 2019; 9:10727-10732. [PMID: 35515313 PMCID: PMC9062465 DOI: 10.1039/c9ra00348g] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/15/2019] [Accepted: 04/01/2019] [Indexed: 01/18/2023] Open
Abstract
The electrochemical oxidation reactions of 2,3′-bisindolylmethanes were affected by the solvent in the positive-ion electrospray ionization mass spectrometry (ESI-MS).
Collapse
Affiliation(s)
- Xu Xu
- Chengdu Institute of Organic Chemistry
- University of Chinese Academy of Sciences
- Chengdu 610041
- China
- University of Chinese Academy of Sciences
| | - Guangyun He
- Chengdu Institute of Organic Chemistry
- University of Chinese Academy of Sciences
- Chengdu 610041
- China
| | - Xiaoying Xu
- Chengdu Institute of Organic Chemistry
- University of Chinese Academy of Sciences
- Chengdu 610041
- China
| | - Zhijun Wu
- Chengdu Institute of Biology
- University of Chinese Academy of Sciences
- Chengdu 610041
- China
| | - Tian Cai
- School of Chemistry and Chemical Engineering
- Southwest University
- Chongqing
- China
| |
Collapse
|
3
|
Pei J, Hsu CC, Zhang R, Wang Y, Yu K, Huang G. Unexpected Reduction of Iminoquinone and Quinone Derivatives in Positive Electrospray Ionization Mass Spectrometry and Possible Mechanism Exploration. JOURNAL OF THE AMERICAN SOCIETY FOR MASS SPECTROMETRY 2017; 28:2454-2461. [PMID: 28786093 DOI: 10.1007/s13361-017-1770-4] [Citation(s) in RCA: 11] [Impact Index Per Article: 1.4] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Subscribe] [Scholar Register] [Received: 04/23/2017] [Revised: 07/13/2017] [Accepted: 07/21/2017] [Indexed: 06/07/2023]
Abstract
Unexpected reduction of iminoquinone (IQ) and quinone derivatives was first reported during positive electrospray ionization mass spectrometry. Upon increasing spray voltage, the intensities of IQ and quinone derivatives decreased drastically, accompanying the increase of the intensities of the reduction products, amodiaquine (AQ) and phenol derivatives. To gain more insight into the mechanism of such reduction, we explored the experimental factors that are influential to corona discharge (CD). The results show that experimental parameters that favor severe CD, including metal spray emitter, using water as spray solvent, sheath gas with low dielectric strength (e.g., nitrogen), and shorter spray tip-to-mass spectrometer inlet distance, facilitated the reduction of IQ and quinone derivatives, implying that the reduction should be closely related to CD in the gas phase. Graphical Abstract ᅟ.
Collapse
Affiliation(s)
- Jiying Pei
- School of Marine Sciences, Guangxi University, Nanning, 530004, People's Republic of China
- Department of Chemistry, School of Chemistry and Materials Science, University of Science and Technology of China (USTC), Hefei, 230026, People's Republic of China
| | - Cheng-Chih Hsu
- Department of Chemistry, National Taiwan University, Taipei, 10617, Taiwan
| | - Ruijie Zhang
- School of Marine Sciences, Guangxi University, Nanning, 530004, People's Republic of China
| | - Yinghui Wang
- School of Marine Sciences, Guangxi University, Nanning, 530004, People's Republic of China
| | - Kefu Yu
- School of Marine Sciences, Guangxi University, Nanning, 530004, People's Republic of China
| | - Guangming Huang
- Department of Chemistry, School of Chemistry and Materials Science, University of Science and Technology of China (USTC), Hefei, 230026, People's Republic of China.
| |
Collapse
|
4
|
Konermann L. Addressing a Common Misconception: Ammonium Acetate as Neutral pH "Buffer" for Native Electrospray Mass Spectrometry. JOURNAL OF THE AMERICAN SOCIETY FOR MASS SPECTROMETRY 2017; 28:1827-1835. [PMID: 28710594 DOI: 10.1007/s13361-017-1739-3] [Citation(s) in RCA: 159] [Impact Index Per Article: 19.9] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Subscribe] [Scholar Register] [Received: 05/09/2017] [Revised: 06/14/2017] [Accepted: 06/15/2017] [Indexed: 05/12/2023]
Abstract
Native ESI-MS involves the transfer of intact proteins and biomolecular complexes from solution into the gas phase. One potential pitfall is the occurrence of pH-induced changes that can affect the analyte while it is still surrounded by solvent. Most native ESI-MS studies employ neutral aqueous ammonium acetate solutions. It is a widely perpetuated misconception that ammonium acetate buffers the analyte solution at neutral pH. By definition, a buffer consists of a weak acid and its conjugate weak base. The buffering range covers the weak acid pKa ± 1 pH unit. NH4+ and CH3-COO- are not a conjugate acid/base pair, which means that they do not constitute a buffer at pH 7. Dissolution of ammonium acetate salt in water results in pH 7, but this pH is highly labile. Ammonium acetate does provide buffering around pH 4.75 (the pKa of acetic acid) and around pH 9.25 (the pKa of ammonium). This implies that neutral ammonium acetate solutions electrosprayed in positive ion mode will likely undergo acidification down to pH 4.75 ± 1 in the ESI plume. Ammonium acetate nonetheless remains a useful additive for native ESI-MS. It is a volatile electrolyte that can mimic the solvation properties experienced by proteins under physiological conditions. Also, a drop from pH 7 to around pH 4.75 is less dramatic than the acidification that would take place in pure water. It is hoped that the habit of referring to pH 7 solutions as ammonium acetate "buffer" will disappear from the literature. Ammonium acetate "solution" should be used instead. Graphical Abstract ᅟ.
Collapse
Affiliation(s)
- Lars Konermann
- Department of Chemistry, The University of Western Ontario, London, ON, N6A 5B7, Canada.
| |
Collapse
|
5
|
Hassan I, Pavlov J, Errabelli R, Attygalle AB. Oxidative Ionization Under Certain Negative-Ion Mass Spectrometric Conditions. JOURNAL OF THE AMERICAN SOCIETY FOR MASS SPECTROMETRY 2017; 28:270-277. [PMID: 27822704 DOI: 10.1007/s13361-016-1527-5] [Citation(s) in RCA: 17] [Impact Index Per Article: 2.1] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Subscribe] [Scholar Register] [Received: 06/22/2016] [Revised: 10/09/2016] [Accepted: 10/10/2016] [Indexed: 06/06/2023]
Abstract
1,4-Hydroquinone and several other phenolic compounds generate (M - 2) -• radical-anions, rather than deprotonated molecules, under certain negative-ion mass spectrometric conditions. In fact, spectra generated under helium-plasma ionization (HePI) conditions from 1,4-hydroquinone and 1,4-benzoquinone (by electron capture) were practically indistinguishable. Because this process involves a net loss of H• and H+, it can be termed oxidative ionization. The superoxide radical-anion (O2-•), known to be present in many atmospheric-pressure plasma ion sources operated in the negative mode, plays a critical role in the oxidative ionization process. The presence of a small peak at m/z 142 in the spectrum of 1,4-hydroquinone, but not in that of 1,4-benzoquinone, indicated that the initial step in the oxidative ionization process is the formation of an O2-• adduct. On the other hand, under bona fide electrospray ionization (ESI) conditions, 1,4-hydroquinone generates predominantly an (M - 1) - ion. It is known that at sufficiently high capillary voltages, corona discharges begin to occur even in an ESI source. At lower ESI capillary voltages, deprotonation predominates; as the capillary voltage is raised, the abundance of O2-• present in the plasma increases, and the source in turn increasingly behaves as a composite ESI/APCI source. While maintaining post-ionization ion activation to a minimum (to prevent fragmentation), and monitoring the relative intensities of the m/z 109 (due to deprotonation) and 108 (oxidative ionization) peaks recorded from 1,4-hydroquinone, a semiquantitative estimation of the APCI contribution to the overall ion-generation process can be obtained. Graphical Abstract ᅟ.
Collapse
Affiliation(s)
- Isra Hassan
- Center for Mass Spectrometry, Department of Chemistry, Chemical Biology, and Biomedical Engineering, Stevens Institute of Technology, Hoboken, NJ, 07030, USA
| | - Julius Pavlov
- Center for Mass Spectrometry, Department of Chemistry, Chemical Biology, and Biomedical Engineering, Stevens Institute of Technology, Hoboken, NJ, 07030, USA
| | - Ramu Errabelli
- Center for Mass Spectrometry, Department of Chemistry, Chemical Biology, and Biomedical Engineering, Stevens Institute of Technology, Hoboken, NJ, 07030, USA
| | - Athula B Attygalle
- Center for Mass Spectrometry, Department of Chemistry, Chemical Biology, and Biomedical Engineering, Stevens Institute of Technology, Hoboken, NJ, 07030, USA.
| |
Collapse
|
6
|
Yuill EM, Baker LA. Electrochemical Aspects of Mass Spectrometry: Atmospheric Pressure Ionization and Ambient Ionization for Bioanalysis. ChemElectroChem 2017. [DOI: 10.1002/celc.201600751] [Citation(s) in RCA: 10] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/31/2022]
Affiliation(s)
- Elizabeth M. Yuill
- Department of Chemistry; Indiana University; 800 E. Kirkwood Avenue Bloomington, Indiana 47405 USA
| | - Lane A. Baker
- Department of Chemistry; Indiana University; 800 E. Kirkwood Avenue Bloomington, Indiana 47405 USA
| |
Collapse
|
7
|
Pei J, Hsu CC, Wang Y, Yu K. Corona discharge-induced reduction of quinones in negative electrospray ionization mass spectrometry. RSC Adv 2017. [DOI: 10.1039/c7ra08523k] [Citation(s) in RCA: 9] [Impact Index Per Article: 1.1] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/21/2022] Open
Abstract
Quinone reduction during negative ESI MS was illustrated to be closely related to corona discharge (CD).
Collapse
Affiliation(s)
- Jiying Pei
- School of Marine Sciences
- Guangxi University
- Nanning
- P. R. China
- Coral Reef Research Center of China
| | - Cheng-Chih Hsu
- Department of Chemistry
- National Taiwan University
- Taipei 10617
- Taiwan
| | - Yinghui Wang
- School of Marine Sciences
- Guangxi University
- Nanning
- P. R. China
- Coral Reef Research Center of China
| | - Kefu Yu
- School of Marine Sciences
- Guangxi University
- Nanning
- P. R. China
- Coral Reef Research Center of China
| |
Collapse
|
8
|
Pichavant L, Guillermain C, Harakat D, Coqueret X. Photo-initiated copolymerization of allyl and vinyl ethers with dialkyl fumarates: A mechanistic investigation by ESI mass spectrometry. Eur Polym J 2016. [DOI: 10.1016/j.eurpolymj.2016.05.003] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.2] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/16/2022]
|
9
|
2015 White Paper on recent issues in bioanalysis: focus on new technologies and biomarkers (Part 1 – small molecules by LCMS). Bioanalysis 2015; 7:2913-25. [DOI: 10.4155/bio.15.204] [Citation(s) in RCA: 31] [Impact Index Per Article: 3.1] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 02/05/2023] Open
Abstract
The 2015 9th Workshop on Recent Issues in Bioanalysis (9th WRIB) took place in Miami, Florida with participation of over 600 professionals from pharmaceutical and biopharmaceutical companies, biotechnology companies, contract research organizations and regulatory agencies worldwide. It is once again a 5-day week long event – a full immersion bioanalytical week – specifically designed to facilitate sharing, reviewing, discussing and agreeing on approaches to address the most current issues of interest in bioanalysis. The topics covered included both small and large molecules, and involved LCMS, hybrid LBA/LCMS, LBA approaches including the focus on biomarkers and immunogenicity. This 2015 White Paper encompasses recommendations that emerged from the extensive discussions held during the workshop, and is aimed to provide the bioanalytical community with key information and practical solutions on topics and issues addressed, in an effort to advance scientific excellence, improve quality and deliver better regulatory compliance. Due to its length, the 2015 edition of this comprehensive White Paper has been divided into three parts. Part 1 covers the recommendations for small molecule bioanalysis using LCMS. Part 2 (hybrid LBA/LCMS and regulatory agencies’ inputs) and Part 3 (large molecule bioanalysis using LBA, biomarkers and immunogenicity) will also be published in volume 7 of Bioanalysis, issues 23 and 24, respectively.
Collapse
|
10
|
Tang C, Tan J, Jin J, Xi S, Li H, Xie Q, Peng X. Observation and confirmation of oxidation reactions occurring on ultra-high-performance liquid chromatography columns. RAPID COMMUNICATIONS IN MASS SPECTROMETRY : RCM 2015; 29:1863-1873. [PMID: 26411507 DOI: 10.1002/rcm.7291] [Citation(s) in RCA: 4] [Impact Index Per Article: 0.4] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Received: 03/02/2015] [Revised: 06/16/2015] [Accepted: 07/27/2015] [Indexed: 06/05/2023]
Abstract
RATIONALE Ultra-high-performance liquid chromatography coupled with electrospray ionization mass spectrometry (UPLC/ESI-MS) has been frequently used for chemical analysis. A redox reaction in the ESI source has been observed during the ionization process. However, it is still unclear whether this redox reaction can take place on UPLC columns. METHODS In this study, the oxidation reactions potentially occurring on UPLC columns were investigated using polyphenols including baicalin, baicalein, propyl gallate (PG), quercetin-3-rhamnoside (QR), rutin, naringin and 2,3,5,4'-tetrahydroxystilbene-2-Ο-β-D-glucoside (THS-G) as model compounds. The on-column oxidation reaction was ascertained by post-column infusion of antioxidants such as ammonium sulfide ((NH4)2S). The oxidized products were reduced to their parent forms in the ESI source. This on-column oxidation reaction was further confirmed by means of post-column infusion of baicalin solution. RESULTS On-column oxidation reactions were observed and confirmed for baicalin, baicalein, PG, rutin, and QR. The exact reaction site was located at the outlet frits of the UPLC columns. (NH4)2S was proved to be the most suitable reducing agent among the tested antioxidants for eliminating negative effects caused by on-column oxidation reaction. It was subsequently proposed to be an efficient additive to suppress oxidation reactions in the ESI source. CONCLUSIONS Oxidation reactions can take place at the outlet frits of UPLC columns. Ascertaining on-column oxidation reactions and consequently eliminating relevant negative effects are of great interest for determination of oxidation-sensitive compounds such as polyphenols.
Collapse
Affiliation(s)
- Caiming Tang
- State Key Laboratory of Organic Geochemistry, Guangzhou Institute of Geochemistry, Chinese Academy of Sciences, Guangzhou, 510640, China
- University of Chinese Academy of Sciences, Beijing, 100049, China
| | - Jianhua Tan
- College of Natural Resources and Environment, South China Agricultural University, Guangzhou, 510642, China
- Guangzhou Quality Supervision and Testing Institute, Guangzhou, 510110, China
| | - Jiabin Jin
- State Key Laboratory of Organic Geochemistry, Guangzhou Institute of Geochemistry, Chinese Academy of Sciences, Guangzhou, 510640, China
- University of Chinese Academy of Sciences, Beijing, 100049, China
| | - Shaofeng Xi
- Guangzhou Quality Supervision and Testing Institute, Guangzhou, 510110, China
| | - Huiyong Li
- Guangzhou Quality Supervision and Testing Institute, Guangzhou, 510110, China
| | - Qilai Xie
- College of Natural Resources and Environment, South China Agricultural University, Guangzhou, 510642, China
| | - Xianzhi Peng
- State Key Laboratory of Organic Geochemistry, Guangzhou Institute of Geochemistry, Chinese Academy of Sciences, Guangzhou, 510640, China
| |
Collapse
|
11
|
Liquid chromatography-mass spectrometry platform for both small neurotransmitters and neuropeptides in blood, with automatic and robust solid phase extraction. Sci Rep 2015; 5:9308. [PMID: 25791195 PMCID: PMC5380133 DOI: 10.1038/srep09308] [Citation(s) in RCA: 43] [Impact Index Per Article: 4.3] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/19/2014] [Accepted: 02/19/2015] [Indexed: 11/09/2022] Open
Abstract
Neurons communicate via chemical signals called neurotransmitters (NTs). The numerous identified NTs can have very different physiochemical properties (solubility, charge, size etc.), so quantification of the various NT classes traditionally requires several analytical platforms/methodologies. We here report that a diverse range of NTs, e.g. peptides oxytocin and vasopressin, monoamines adrenaline and serotonin, and amino acid GABA, can be simultaneously identified/measured in small samples, using an analytical platform based on liquid chromatography and high-resolution mass spectrometry (LC-MS). The automated platform is cost-efficient as manual sample preparation steps and one-time-use equipment are kept to a minimum. Zwitter-ionic HILIC stationary phases were used for both on-line solid phase extraction (SPE) and liquid chromatography (capillary format, cLC). This approach enabled compounds from all NT classes to elute in small volumes producing sharp and symmetric signals, and allowing precise quantifications of small samples, demonstrated with whole blood (100 microliters per sample). An additional robustness-enhancing feature is automatic filtration/filter back-flushing (AFFL), allowing hundreds of samples to be analyzed without any parts needing replacement. The platform can be installed by simple modification of a conventional LC-MS system.
Collapse
|
12
|
Pei J, Zhou X, Wang X, Huang G. Alleviation of electrochemical oxidation for peptides and proteins in electrospray ionization: obtaining more accurate mass spectra with induced high voltage. Anal Chem 2015; 87:2727-33. [PMID: 25626082 DOI: 10.1021/ac503990a] [Citation(s) in RCA: 13] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/24/2023]
Abstract
Accurate mass spectrometry (MS) signal for peptide/protein analysis, which could be affected by various MS conditions, plays an essential role in identification and quantification of biological samples. Herein, we tried to alleviate the possible interferences from electrochemical oxidations during electrospray ionization (ESI). Three most common electrochemical oxidation reactions in ESI include oxidation of analyte, solvent, and electrode. With introduction of induced electrospray ionization (IESI) (a variant form of ESI), these interferences were significantly alleviated for peptides/proteins. That effect was also tested with flow injection experiments with different solution flow rates, electrolyte concentrations and solvent compositions, which was to simulate various chromatography conditions in conventional liquid chromatography (LC) separations. For all chromatography conditions tested, electrochemical oxidation was significantly alleviated for the absence of physical contact between spray solution and electrode.
Collapse
Affiliation(s)
- Jiying Pei
- Department of Chemistry, School of Chemistry and Materials Science, University of Science and Technology of China , Hefei 230026, People's Republic of China
| | | | | | | |
Collapse
|
13
|
Oberacher H, Pitterl F, Erb R, Plattner S. Mass spectrometric methods for monitoring redox processes in electrochemical cells. MASS SPECTROMETRY REVIEWS 2015; 34:64-92. [PMID: 24338642 PMCID: PMC4286209 DOI: 10.1002/mas.21409] [Citation(s) in RCA: 48] [Impact Index Per Article: 4.8] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Figures] [Subscribe] [Scholar Register] [Received: 03/28/2013] [Revised: 07/24/2013] [Accepted: 08/12/2013] [Indexed: 06/03/2023]
Abstract
Electrochemistry (EC) is a mature scientific discipline aimed to study the movement of electrons in an oxidation-reduction reaction. EC covers techniques that use a measurement of potential, charge, or current to determine the concentration or the chemical reactivity of analytes. The electrical signal is directly converted into chemical information. For in-depth characterization of complex electrochemical reactions involving the formation of diverse intermediates, products and byproducts, EC is usually combined with other analytical techniques, and particularly the hyphenation of EC with mass spectrometry (MS) has found broad applicability. The analysis of gases and volatile intermediates and products formed at electrode surfaces is enabled by differential electrochemical mass spectrometry (DEMS). In DEMS an electrochemical cell is sampled with a membrane interface for electron ionization (EI)-MS. The chemical space amenable to EC/MS (i.e., bioorganic molecules including proteins, peptides, nucleic acids, and drugs) was significantly increased by employing electrospray ionization (ESI)-MS. In the simplest setup, the EC of the ESI process is used to analytical advantage. A limitation of this approach is, however, its inability to precisely control the electrochemical potential at the emitter electrode. Thus, particularly for studying mechanistic aspects of electrochemical processes, the hyphenation of discrete electrochemical cells with ESI-MS was found to be more appropriate. The analytical power of EC/ESI-MS can further be increased by integrating liquid chromatography (LC) as an additional dimension of separation. Chromatographic separation was found to be particularly useful to reduce the complexity of the sample submitted either to the EC cell or to ESI-MS. Thus, both EC/LC/ESI-MS and LC/EC/ESI-MS are common.
Collapse
Affiliation(s)
- Herbert Oberacher
- Institute of Legal Medicine and Core Facility Metabolomics, Innsbruck Medical UniversityInnsbruck, Austria
| | - Florian Pitterl
- Institute of Legal Medicine and Core Facility Metabolomics, Innsbruck Medical UniversityInnsbruck, Austria
| | - Robert Erb
- Institute of Legal Medicine and Core Facility Metabolomics, Innsbruck Medical UniversityInnsbruck, Austria
| | - Sabine Plattner
- Institute of Legal Medicine and Core Facility Metabolomics, Innsbruck Medical UniversityInnsbruck, Austria
| |
Collapse
|
14
|
Sojo LE, Chahal N, Keller BO. Oxidation of catechols during positive ion electrospray mass spectrometric analysis: evidence for in-source oxidative dimerization. RAPID COMMUNICATIONS IN MASS SPECTROMETRY : RCM 2014; 28:2181-2190. [PMID: 25178722 DOI: 10.1002/rcm.7011] [Citation(s) in RCA: 13] [Impact Index Per Article: 1.2] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 05/21/2014] [Revised: 07/25/2014] [Accepted: 08/03/2014] [Indexed: 06/03/2023]
Abstract
RATIONALE Catechols are an important class of analytes occurring in many natural and synthetic products. Electrospray ionization in negative mode is the preferred way of ion generation for these compounds; however, studies in positive ion mode can reveal their potential for in-source oxidation and further structural changes, some of which may also occur in the solution phase. Therefore in-source oxidation can provide a forward look into the potential for solution oxidation. METHODS 1:1 Acetonitrile/water solutions of catechol (Cat), 4,5-dichlorocatechol (4,5-DCC), 3,4-dichlorocatechol (3,4-DCC) and tetrachlorocatechol (TCC) were analyzed by positive ion ultrahigh-performance liquid chromatography (UHPLC/ESI-MS) and UHPLC/ESI-MS/MS under various emitter voltages to assess their liability towards in-source oxidation. Structural information for in-source generated compounds was obtained through the use of product ion scans. RESULTS Using catechols as probe compounds, we have demonstrated that under the conditions used in many analytical laboratories in-source oxidation can severely affect the sensitivity and response functions of an analyte. Under standard UHPLC conditions (300 μL/min flow rate), Cat, 3,4-DCC, 4,5-DCC and TCC can undergo in-source oxidation. The extent of oxidation is dependent either on the instrument or on the characteristics of the emitter. This is evident by a change in the isotopic pattern of these compounds and the generation of ions at lower m/z values due to a loss of 1 and/or 2 hydrogens and electrons. In the case of catechol, the formation of a dimer resulting from in-source oxidation reactions was observed. This dimer has the same fragmentation pattern as the dimer generated by oxidation in the solution phase. CONCLUSIONS The present work demonstrates the potential of positive ion ESI for oxidizing electroactive compounds during regular analytical operation using commercially available mass spectrometers. Using Cat and some of its chlorinated analogues as probe compounds, we have demonstrated that under the conditions used in many analytical laboratories in-source oxidation and dimerization can and does take place.
Collapse
Affiliation(s)
- Luis E Sojo
- Compound Properties Group, Xenon Pharmaceuticals Inc., Burnaby, BC, Canada, V5G 4W8; Department of Chemistry, Simon Fraser University, Burnaby, BC, Canada, V5A 1S6
| | | | | |
Collapse
|
15
|
Hongo Y, Nakamura T, Takahashi S, Motoyama T, Hayashi T, Hirota H, Osada H, Koshino H. Detection of oxygen addition peaks for terpendole E and related indole-diterpene alkaloids in a positive-mode ESI-MS. JOURNAL OF MASS SPECTROMETRY : JMS 2014; 49:537-542. [PMID: 24913406 PMCID: PMC4207197 DOI: 10.1002/jms.3360] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.2] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 07/17/2013] [Revised: 03/05/2014] [Accepted: 03/10/2014] [Indexed: 05/29/2023]
Abstract
This report describes that a regular positive electrospray ionization mass spectrometry (MS) analysis of terpendoles often causes unexpected oxygen additions to form [M + H + O](+) and [M + H + 2O](+), which might be a troublesome in the characterization of new natural analogues. The intensities of [M + H + O](+) and [M + H + 2O](+) among terpendoles were unpredictable and fluctuated largely. Simple electrochemical oxidation in electrospray ionization was insufficient to explain the phenomenon. So we studied factors to form [M + H + O](+) and [M + H + 2O](+) using terpendole E and natural terpendoles together with some model indole alkaloids. Similar oxygen addition was observed for 1,2,3,4-tetrahydrocyclopent[b]indole, which is corresponding to the substructure of terpendole E. In tandem MS experiments, a major fragment ion at m/z 130 from protonated terpendole E was assigned to the substructure containing indole. When the [M + H + O](+) was selected as a precursor ion, the ion shifted to m/z 146. The same 16 Da shift of fragments was also observed for 1,2,3,4-tetrahydrocyclopent[b]indole, indicating that the oxygen addition of terpendole E took place at the indole portion. However, the oxygen addition was absent for some terpendoles, even whose structure resembles terpendole E. The breakdown curves characterized the tandem MS features of terpendoles. Preferential dissociation into m/z 130 suggested the protonation tendency at the indole site. Terpendoles that are preferentially protonated at indole tend to form oxygen addition peaks, suggesting that the protonation feature contributes to the oxygen additions in some degrees.
Collapse
Affiliation(s)
| | | | | | | | | | | | - Hiroyuki Osada
- Antibiotics Laboratory, RIKENWako, Japan
- Center for Sustainable Resource Science, RIKENWako, Japan
| | - Hiroyuki Koshino
- Global Research Cluster, RIKENWako, Japan
- Synthetic Organic Chemistry Laboratory, RIKENWako, Japan
| |
Collapse
|
16
|
Plattner S, Erb R, Chervet JP, Oberacher H. Studying the reducing potencies of antioxidants with the electrochemistry inherently present in electrospray ionization-mass spectrometry. Anal Bioanal Chem 2014; 406:213-24. [PMID: 24202195 PMCID: PMC3877428 DOI: 10.1007/s00216-013-7445-5] [Citation(s) in RCA: 8] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/23/2013] [Revised: 10/14/2013] [Accepted: 10/16/2013] [Indexed: 02/01/2023]
Abstract
In this proof-of-principle study, the applicability of electrospray ionization-mass spectrometry (ESI-MS) to characterize the reducing potencies of natural antioxidants is demonstrated. The ESI source represents a controlled-current electrochemical cell. The interfacial potential at the emitter electrode will be at or near the electrochemical potential of those reactions that sufficiently supply all the required current for the ESI circuit. Indicator molecules prone to oxidation in ESI such as amodiaquine were used to visualize the impact of reducing compounds on the interfacial potential. The extent of inhibition of the oxidation of the indicator molecule was found to be dependent on the kind and amount of antioxidant added. Concentration-inhibition curves were constructed and used to compare reducing potencies and to rank antioxidants. This ranking was found to be dependent on the electrode material-indicator molecule combination applied. For fast and automated characterization of the reducing potencies of electrochemically active molecules, a flow-injection system was combined with ESI-MS. Liquid chromatography was used to process complex biological samples, such as red and white wine. Due to their high content of different polyphenols, red wine fractions were found to exhibit higher reducing potencies than the corresponding white wine fractions. Furthermore, for 14 important natural antioxidants, the results obtained with the controlled-current EC-ESI-MS assay were compared to those obtained with chemical antioxidant assays. Irrespectively of the kind of assay used to test the reducing potency, gallic acid, quercetin, and epicatechin were found to be potent reductants. Other antioxidants performed well in one particular assay only. This observation suggests that different kinds of redox and antioxidant chemistry were assessed with each of the assays applied. Therefore, several assays should be used to comprehensively study antioxidants and their reducing potencies.
Collapse
Affiliation(s)
- Sabine Plattner
- Institute of Legal Medicine and Core Facility Metabolomics, Innsbruck Medical University, Müllerstraße 44, 6020 Innsbruck, Austria
| | - Robert Erb
- Institute of Legal Medicine and Core Facility Metabolomics, Innsbruck Medical University, Müllerstraße 44, 6020 Innsbruck, Austria
| | | | - Herbert Oberacher
- Institute of Legal Medicine and Core Facility Metabolomics, Innsbruck Medical University, Müllerstraße 44, 6020 Innsbruck, Austria
| |
Collapse
|
17
|
Siegel D, Permentier H, Reijngoud DJ, Bischoff R. Chemical and technical challenges in the analysis of central carbon metabolites by liquid-chromatography mass spectrometry. J Chromatogr B Analyt Technol Biomed Life Sci 2013; 966:21-33. [PMID: 24326023 DOI: 10.1016/j.jchromb.2013.11.022] [Citation(s) in RCA: 46] [Impact Index Per Article: 3.8] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/09/2013] [Revised: 11/10/2013] [Accepted: 11/12/2013] [Indexed: 11/18/2022]
Abstract
This review deals with chemical and technical challenges in the analysis of small-molecule metabolites involved in central carbon and energy metabolism via liquid-chromatography mass-spectrometry (LC-MS). The covered analytes belong to the prominent pathways in biochemical carbon oxidation such as glycolysis or the tricarboxylic acid cycle and, for the most part, share unfavorable properties such as a high polarity, chemical instability or metal-affinity. The topic is introduced by selected examples on successful applications of metabolomics in the clinic. In the core part of the paper, the structural features of important analyte classes such as nucleotides, coenzyme A thioesters or carboxylic acids are linked to "problematic hotspots" along the analytical chain (sample preparation and-storage, separation and detection). We discuss these hotspots from a chemical point of view, covering issues such as analyte degradation or interactions with metals and other matrix components. Based on this understanding we propose solutions wherever available. A major notion derived from these considerations is that comprehensive carbon metabolomics inevitably requires multiple, complementary analytical approaches covering different chemical classes of metabolites.
Collapse
Affiliation(s)
- David Siegel
- University of Groningen, Department of Pharmacy, Analytical Biochemistry, Antonius-Deusinglaan 1, 9713 AV Groningen, The Netherlands
| | - Hjalmar Permentier
- University of Groningen, Department of Pharmacy, Mass Spectrometry Core Facility, Antonius-Deusinglaan 1, 9713 AV Groningen, The Netherlands
| | - Dirk-Jan Reijngoud
- University Medical Center Groningen, Department of Pediatrics, Center for Liver, Digestive and Metabolic Diseases, Antonius Deusinglaan 1, 9713 AV Groningen, The Netherlands
| | - Rainer Bischoff
- University of Groningen, Department of Pharmacy, Analytical Biochemistry, Antonius-Deusinglaan 1, 9713 AV Groningen, The Netherlands.
| |
Collapse
|
18
|
Antonakis MM, Tsirigotaki A, Kanaki K, Milios CJ, Pergantis SA. Bipolar mass spectrometry of labile coordination complexes, redox active inorganic compounds, and proteins using a glass nebulizer for sonic-spray ionization. JOURNAL OF THE AMERICAN SOCIETY FOR MASS SPECTROMETRY 2013; 24:1250-1259. [PMID: 23761045 DOI: 10.1007/s13361-013-0668-z] [Citation(s) in RCA: 7] [Impact Index Per Article: 0.6] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 01/28/2013] [Revised: 04/08/2013] [Accepted: 04/30/2013] [Indexed: 06/02/2023]
Abstract
In this study, we report on the development of a novel nebulizer configuration for sonic-spray ionization (SSI) mass spectrometry (MS), more specifically for a version of SSI that is referred to as Venturi easy ambient sonic-spray ionization (V-EASI) MS. The developed nebulizer configuration is based on a commercially available pneumatic glass nebulizer that has been used extensively for aerosol formation in atomic spectrometry. In the present study, the nebulizer was modified in order to achieve efficient V-EASI-MS operation. Upon evaluating this system, it has been demonstrated that V-EASI-MS offers some distinct advantages for the analysis of coordination compounds and redox active inorganic compounds over the predominantly used electrospray ionization (ESI) technique. Such advantages, for this type of compounds, are demonstrated here for the first time. More specifically, a series of labile heptanuclear heterometallic [Cu(II) 6Ln(III)] clusters held together with artificial amino acid ligands, in addition to easily oxidized inorganic oxyanions of selenium and arsenic, were analyzed. The observed advantages pertain to V-EASI appearing to be a "milder" ionization source than ESI, not requiring electrical potentials for gas phase ion formation, thus eliminating the possibility of unwanted redox transformations, allowing for the "simultaneous" detection of negative and positive ions (bipolar analysis) without the need to change source ionization conditions, and also not requiring the use of syringes and delivery pumps. Because of such features, especially because of the absence of ionization potentials, EASI can be operated with minimal requirements for source parameter optimization. We observed that source temperature and accelerating voltage do not seem to affect labile compounds to the extent they do in ESI-MS. In addition, bipolar analysis of proteins was demonstrated here by acquiring both positive and negative ion mass spectra from the same protein solutions, without the need to independently adjust solution and source conditions in each mode. Finally, the simple and efficient operation of a dual-nebulizer configuration was demonstrated for V-EASI-MS for the first time.
Collapse
Affiliation(s)
- Manolis M Antonakis
- Environmental Chemical Processes Laboratory, Department of Chemistry, University of Crete, Voutes Campus, Heraklion, 71003, Greece
| | | | | | | | | |
Collapse
|