1
|
Szpot P, Tusiewicz K, Wachełko O, Zawadzki M. Application of UHPLC-QqQ-MS/MS Method for Quantification of Beta-Adrenergic Blocking Agents (β-Blockers) in Human Postmortem Specimens. Molecules 2024; 29:4585. [PMID: 39407515 PMCID: PMC11477679 DOI: 10.3390/molecules29194585] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/01/2024] [Revised: 09/23/2024] [Accepted: 09/24/2024] [Indexed: 10/20/2024] Open
Abstract
Betablockers are one of the most frequently used medications in cardiology. They can lead to fatal drops in blood pressure and heart rhythm disturbances. Death is functional, and poisoning with this group of drugs can be difficult to detect. The liquid-liquid extraction (LLE) method developed using ethyl acetate at pH 9 successfully identified 18 β-blockers in human blood. The method's limit of quantification (LOQ) was in the range of 0.1 to 0.5 ng/mL. No carryover of substances between samples was detected, and no interfering ion current signals were observed in the biological samples at the retention times of the compounds or internal standards. All compounds had a coefficient of determination (R2) above 0.995. Intraday and interday precision (RSD%) and accuracy (RE%) for low and high QC levels were within 1.7-12.3% and -14.4 to 14.1%, respectively. Very good recovery (80.0-119.6%) and matrix effect (±20.0%) values were achieved for all compounds. In addition, fragmentation spectra were collected for all the examined substances, and high-resolution spectra were presented for landiolol and metipranolol, because they are not available in commercial HRMS spectra databases. The developed method was applied in authentic postmortem samples.
Collapse
Affiliation(s)
- Paweł Szpot
- Department of Forensic Medicine, Wroclaw Medical University, 4 J. Mikulicza-Radeckiego Street, 50345 Wroclaw, Poland
| | - Kaja Tusiewicz
- Department of Forensic Medicine, Wroclaw Medical University, 4 J. Mikulicza-Radeckiego Street, 50345 Wroclaw, Poland
| | - Olga Wachełko
- Institute of Toxicology Research, 45 Kasztanowa Street, 55093 Borowa, Poland
| | - Marcin Zawadzki
- Faculty of Medicine, Department of Social Sciences and Infectious Diseases, Wroclaw University of Science and Technology, 27 Wybrzeże Wyspiańskiego, 50370 Wroclaw, Poland
| |
Collapse
|
2
|
de Castilho Alves Morais EM, Mendes TV, Arnoni ED, Gorup LF, Rosa MA, Moreira AJ, Figueiredo EC. Magnetic particle spray mass spectrometry for the determination of beta-blockers in plasma samples. Mikrochim Acta 2024; 191:620. [PMID: 39320493 DOI: 10.1007/s00604-024-06698-2] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/01/2024] [Accepted: 09/07/2024] [Indexed: 09/26/2024]
Abstract
Magnetic particle spray mass spectrometry (MPS-MS), an innovative ambient ionization technique proposed by our research group, was employed to determine beta-blockers in human plasma samples. A dispersive solid phase extraction of atenolol, metoprolol, labetalol, propranolol, nadolol, and pindolol was carried out using magnetic molecularly imprinted polymer (M-MIP) particles that were attached to the tip of a metal probe, which was placed in the mass spectrometer inlet. A solvent (1% formic acid in methanol) was dispensed on the particles, and the Taylor cone was formed around them (in high voltage). The analytes were desorbed/ionized and determined by a triple quadrupole mass spectrometer. M-MIP was synthesized with oxprenolol as a pseudo-template, demonstrating good selectivity to beta-blockers compared with no-analog molecules, with an adsorption process occurring in monolayers, according to isotherm studies. Kinetic experiments indicated chemisorption as the predominant M-MIP/analyte interaction. The analytical curves were linear (R2 > 0.98), and the limit of quantification was 3 µg L-1 for all the analytes. Limits of detection ranged from 0.64 to 2.41 µg L-1. Precisions (relative standard deviation) and accuracies (relative error) ranged from 3.95 to 21.20% and -17.05 to 18.93%, respectively. MPS-MS proved to be a simple, sensitive, and advantageous technique compared with conventional approaches. The analyses were fast, requiring no chromatographic separation and without ionic suppression. The method is aligned with green chemistry principles, requiring minimal sample, solvent, and sorbent amounts. MPS-MS successfully integrates sample preparation and ambient ionization mass spectrometry and holds great potential for application with other sorbents, samples, and analytes.
Collapse
Affiliation(s)
| | - Tássia Venga Mendes
- Laboratory of Toxicant and Drug Analyses, Faculty of Pharmaceutical Sciences, Federal University of Alfenas, Alfenas, MG, 37130-001, Brazil
| | - Estela Domingos Arnoni
- Laboratory of Toxicant and Drug Analyses, Faculty of Pharmaceutical Sciences, Federal University of Alfenas, Alfenas, MG, 37130-001, Brazil
| | - Luiz Fernando Gorup
- Institute of Chemistry, Federal University of Alfenas, Alfenas, MG, 37130-001, Brazil
- Department of Chemistry, Interdiscipli5nary Laboratory of Electrochemistry and Ceramics (LIEC), Federal University of São Carlos, São Carlos, SP, 13565-905, Brazil
- School of Chemistry and Food Science, Federal University of Rio Grande, Rio Grande, RS, 96203-900, Brazil
- Department of Chemistry, Federal University of Juiz de Fora, Juiz de Fora, MG, Brazil
| | - Mariana Azevedo Rosa
- Laboratory of Toxicant and Drug Analyses, Faculty of Pharmaceutical Sciences, Federal University of Alfenas, Alfenas, MG, 37130-001, Brazil
| | - Ailton José Moreira
- Institute of Chemistry, São Paulo State University (UNESP), Araraquara, SP, 14800-060, Brazil
| | - Eduardo Costa Figueiredo
- Laboratory of Toxicant and Drug Analyses, Faculty of Pharmaceutical Sciences, Federal University of Alfenas, Alfenas, MG, 37130-001, Brazil.
| |
Collapse
|
3
|
Sajid M. Dispersive liquid-liquid microextraction: Evolution in design, application areas, and green aspects. Trends Analyt Chem 2022. [DOI: 10.1016/j.trac.2022.116636] [Citation(s) in RCA: 3] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/30/2022]
|
4
|
Arabkhani B, Goudarzi N, Bagherian G, Chamjangali MA. Application of Tandem Dispersive Liquid-Liquid Microextraction as an Efficient Method for Preconcentration of Two Antidepressant Drugs in Real Samples Combined with High Performance Liquid Chromatography. J Chromatogr Sci 2021; 60:96-103. [PMID: 33870416 DOI: 10.1093/chromsci/bmab038] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/30/2020] [Revised: 02/21/2021] [Indexed: 11/14/2022]
Abstract
In the present work, tandem dispersive liquid-liquid microextraction (TDLLME) coupled with liquid chromatography was used for the determination of the two antidepressant drugs citalopram (CIT) and sertraline (SER) in complicated matrices. Indeed, the present approach was used to improve the suitability and appropriateness of the dispersive liquid-liquid microextraction (DLLME) method in complicated matrices. Firstly, 10 mL of the sample solution containing the two understudied drugs was extracted into an organic solvent (200 μL of 1,2-dichloromethane) using the DLLME method. Then the extracted analytes were back-extracted into 100 μL of an aqueous acceptor phase. The total extraction time of this method is about 6 min. To achieve the best efficiency for this method, efficient parameters like the kind and volume of the organic solvent and the effect of the ionic strength on the effectiveness of extraction were reviewed and improved. Under the optimized experimental conditions, TDLLME showed good linearity in the range of 100.0-7000.0 ng mL-1. The limits of detection were found to be 10.0 ng mL-1 for CIT and 2.0 ng mL-1 for SER. The relative standard deviation (RSD) is obtained in the range of 0.7-4.1%.
Collapse
Affiliation(s)
- Bahare Arabkhani
- Faculty of Chemistry, Shahrood University of Technology, P.O. Box 36155-316, Shahrood, Iran
| | - Nasser Goudarzi
- Faculty of Chemistry, Shahrood University of Technology, P.O. Box 36155-316, Shahrood, Iran
| | - Ghadamali Bagherian
- Faculty of Chemistry, Shahrood University of Technology, P.O. Box 36155-316, Shahrood, Iran
| | | |
Collapse
|
5
|
Wang Y, Li S, Zhang L, Qi S, Guan H, Liu W, Cheng X, Liu L, Cheng L, Wang C. Chemical Fingerprint Analysis and Simultaneous Determination of Nucleosides and Amino Acids in Kang Fu Xin Liquid by High Performance Liquid Chromatography with Diode Array Detector. CURR PHARM ANAL 2020. [DOI: 10.2174/1573412915666190328215231] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/22/2022]
Abstract
Background and Objective:
Kang Fu Xin liquid (KFX) is an official preparation made from
the ethanol extract product from P. Americana. The present quality control method cannot control the
quality of the preparation well. The aim of the present study is to establish a convenient HPLC method
for multicomponents determination combined with fingerprint analysis for quality control of KFX.
Methods:
An HPLC-DAD method with gradient elution and detective wavelength switching program
was developed to establish HPLC fingerprints of KFX, and 38 batches of KFX were compared and
evaluated by similarity analysis (SA), hierarchical clustering analysis (HCA), and principal component
analysis (PCA). Meanwhile, six nucleosides and three amino acids, including uracil, hypoxanthine, uric
acid, adenosine, xanthine, inosine, tyrosine, phenylalanine and tryptophan in KFX were determined
based on the HPLC fingerprints.
Results:
An HPLC method assisted with gradient elution and wavelength switching program was established
and validated for multicomponents determination combined with fingerprint analysis of KFX.
The results demonstrated that the similarity values of the KFX samples were more than 0.845. PCA
indicated that peaks 4 (hypoxanthine), 7 (xanthine), 9 (tyrosine), 11, 13 and 17 might be the characteristic
contributed components. The nine constituents in KFX, uracil, hypoxanthine, uric acid, adenosine,
xanthine, inosine, tyrosine, phenylalanine and tryptophan, showed good regression (R2 > 0.9997) within
test ranges and the recoveries of the method for all analytes were in the range from 96.74 to 104.24%.
The limits of detections and quantifications for nine constituents in DAD were less than 0.22 and 0.43
μg•mL-1, respectively.
Conclusion:
The qualitative analysis of chemical fingerprints and the quantitative analysis of multiple
indicators provide a powerful and rational way to control the KFX quality for pharmaceutical companies.
Collapse
Affiliation(s)
- Yuwen Wang
- Institute of Chinese Materia Medica, Shanghai University of Traditional Chinese Medicine, Shanghai, China
| | - Shuping Li
- Institute of Chinese Materia Medica, Shanghai University of Traditional Chinese Medicine, Shanghai, China
| | - Liuhong Zhang
- Institute of Chinese Materia Medica, Shanghai University of Traditional Chinese Medicine, Shanghai, China
| | - Shenglan Qi
- Institute of Chinese Materia Medica, Shanghai University of Traditional Chinese Medicine, Shanghai, China
| | - Huida Guan
- Institute of Chinese Materia Medica, Shanghai University of Traditional Chinese Medicine, Shanghai, China
| | - Wei Liu
- Institute of Chinese Materia Medica, Shanghai University of Traditional Chinese Medicine, Shanghai, China
| | - Xuemei Cheng
- Institute of Chinese Materia Medica, Shanghai University of Traditional Chinese Medicine, Shanghai, China
| | - Li Liu
- Inner Mongolia Jingxin Pharmaceutical Co., Ltd, Innermongolia, China
| | - Liang Cheng
- Inner Mongolia Jingxin Pharmaceutical Co., Ltd, Innermongolia, China
| | - Changhong Wang
- Institute of Chinese Materia Medica, Shanghai University of Traditional Chinese Medicine, Shanghai, China
| |
Collapse
|
6
|
Yıldırım S, Erkmen C, Uslu B. Novel Trends in Analytical Methods for β-Blockers: An Overview of Applications in the Last Decade. Crit Rev Anal Chem 2020; 52:131-169. [DOI: 10.1080/10408347.2020.1791043] [Citation(s) in RCA: 7] [Impact Index Per Article: 1.4] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/23/2022]
Affiliation(s)
- Sercan Yıldırım
- Faculty of Pharmacy, Department of Analytical Chemistry, Karadeniz Technical University, Trabzon, Turkey
| | - Cem Erkmen
- Faculty of Pharmacy, Department of Analytical Chemistry, Ankara University, Ankara, Turkey
| | - Bengi Uslu
- Faculty of Pharmacy, Department of Analytical Chemistry, Ankara University, Ankara, Turkey
| |
Collapse
|
7
|
Mompó-Roselló O, Ribera-Castelló A, Simó-Alfonso EF, Ruiz-Angel MJ, García-Alvarez-Coque MC, Herrero-Martínez JM. Extraction of β-blockers from urine with a polymeric monolith modified with 1-allyl-3-methylimidazolium chloride in spin column format. Talanta 2020; 214:120860. [PMID: 32278420 DOI: 10.1016/j.talanta.2020.120860] [Citation(s) in RCA: 15] [Impact Index Per Article: 3.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/13/2020] [Revised: 02/20/2020] [Accepted: 02/21/2020] [Indexed: 12/13/2022]
Abstract
A glycidyl methacrylate-based monolith was modified with imidazolium-based ionic liquid (IL) to be used as stationary phase for solid-phase extraction (SPE). The host monolithic support was prepared by in-situ UV polymerization in spin column format. Two approaches were developed to incorporate the IL into the polymeric monolithic matrix: generation of IL onto the surface monolith, and copolymerization by addition of the IL to the polymerization mixture, which gave the best results. The resulting sorbent materials were morphologically characterized and used for the isolation of five β-blockers from human urine samples. All SPE steps were accomplished by centrifugation, which reduces significantly costs and time in sample treatment. Under optimal conditions, β-blockers were quantitatively retained in the modified monolith at pH 12, and desorbed with a water-methanol mixture, to be subsequently determined via HPLC with UV detection. The limits of detection ranged between 1.4 and 40 μg L-1, and the reproducibility among extraction units (expressed as relative standard deviation) was below 8.2%. The novel phase was successfully applied to the extraction of propranolol in urine samples with recoveries above 90%.
Collapse
Affiliation(s)
- Oscar Mompó-Roselló
- Department of Analytical Chemistry, Faculty of Chemistry, University of Valencia, Dr. Moliner 50, 46100, Burjassot, Valencia, Spain
| | - Ana Ribera-Castelló
- Department of Analytical Chemistry, Faculty of Chemistry, University of Valencia, Dr. Moliner 50, 46100, Burjassot, Valencia, Spain
| | - Ernesto F Simó-Alfonso
- Department of Analytical Chemistry, Faculty of Chemistry, University of Valencia, Dr. Moliner 50, 46100, Burjassot, Valencia, Spain
| | - María José Ruiz-Angel
- Department of Analytical Chemistry, Faculty of Chemistry, University of Valencia, Dr. Moliner 50, 46100, Burjassot, Valencia, Spain
| | - María Celia García-Alvarez-Coque
- Department of Analytical Chemistry, Faculty of Chemistry, University of Valencia, Dr. Moliner 50, 46100, Burjassot, Valencia, Spain
| | - José Manuel Herrero-Martínez
- Department of Analytical Chemistry, Faculty of Chemistry, University of Valencia, Dr. Moliner 50, 46100, Burjassot, Valencia, Spain.
| |
Collapse
|
8
|
Mahmoudi A, Rajabi M. Selective determination of some beta-blockers in urine and plasma samples using continuous flow membrane microextraction coupled with high performance liquid chromatography. J Chromatogr B Analyt Technol Biomed Life Sci 2019; 1128:121768. [PMID: 31491695 DOI: 10.1016/j.jchromb.2019.121768] [Citation(s) in RCA: 8] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/18/2019] [Revised: 08/15/2019] [Accepted: 08/16/2019] [Indexed: 11/30/2022]
Abstract
In this work, an efficient method termed as continuous flow membrane microextraction coupled with high performance liquid chromatography is introduced for a highly selective determination of metoprolol and propranolol in the biological samples. According to this method, an aqueous source phase of the analytes (donor phase, 10 mL) is circulated into an extraction cell, which is separated from an aqueous acceptor phase (100 μL) by a small piece of polypropylene membrane sheet whose pores are impregnated by an organic solvent (1-octanol, 15 μL). The analytes are extracted from the donor phase into the organic solvent. They are subsequently selectively back-extracted into the acceptor solution due to the pH gradient. The proposed method is very convenient and has the capability of being fully automated. It provides a good preconcentration and an excellent repeatability. The extractant is an aqueous phase, and by prevention of the extraction of macromolecules through the membrane, the developed method provides a high sample clean-up. In order to maximize the extraction efficiency, the influential parameters including the type of mediator solvent, pH values for the donor and acceptor solutions, extraction time, ionic strength, stirring rate, and volume of the acceptor solution are optimized. The calibration curves were obtained with a reasonable linearity (r2 = 0.999) in the range of 3-1000 ng mL-1. The limits of detection were 0.5 and 1.0 ng mL-1, and excellent relative standard deviations were obtained (between 3.2% and 4.0%). Finally, the reliability of the procedure is evaluated by determination of metoprolol and propranolol in the human urine and plasma samples, which indicates the suitability, sensitivity, and high sample clean-up of the proposed method.
Collapse
Affiliation(s)
- Atefeh Mahmoudi
- Department of Chemistry, Semnan University, Semnan 2333383-193, Iran
| | - Maryam Rajabi
- Department of Chemistry, Semnan University, Semnan 2333383-193, Iran.
| |
Collapse
|
9
|
Micro-extraction by packed sorbent coupled on-line to a column-switching chromatography system – A case study on the determination of three beta-blockers in human urine. Microchem J 2019. [DOI: 10.1016/j.microc.2019.02.069] [Citation(s) in RCA: 6] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/23/2022]
|
10
|
Moradi P, Asghari A. Highly selective determination of some anti‐depressant drugs in complicated matrices by dual emulsification liquid‐phase microextraction based on filtration followed by high‐performance liquid chromatography. SEPARATION SCIENCE PLUS 2019. [DOI: 10.1002/sscp.201800147] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 02/06/2023]
Affiliation(s)
- Peyman Moradi
- Department of ChemistrySemnan University Semnan Iran
| | | |
Collapse
|
11
|
Dispersive liquid-liquid microextraction based binary extraction techniques prior to chromatographic analysis: A review. Trends Analyt Chem 2018. [DOI: 10.1016/j.trac.2018.08.016] [Citation(s) in RCA: 66] [Impact Index Per Article: 9.4] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/18/2023]
|
12
|
Ge W, Suryoprabowo S, Xu L, Zheng Q, Kuang H. Rapid detection of penbutolol in pig urine using an immunochromatographic test strip. FOOD AGR IMMUNOL 2018. [DOI: 10.1080/09540105.2018.1520203] [Citation(s) in RCA: 6] [Impact Index Per Article: 0.9] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/19/2023] Open
Affiliation(s)
- Wenliang Ge
- Wuxi No.2 people’s hospital, Wuxi, People’s Republic of China
| | - Steven Suryoprabowo
- State Key Lab of Food Science and Technology, School of Food Science and Technology, Jiangnan University, Wuxi, People’s Republic of China
| | - Liguang Xu
- State Key Lab of Food Science and Technology, School of Food Science and Technology, Jiangnan University, Wuxi, People’s Republic of China
| | | | - Hua Kuang
- State Key Lab of Food Science and Technology, School of Food Science and Technology, Jiangnan University, Wuxi, People’s Republic of China
| |
Collapse
|
13
|
Mahmoudi Alami F, Mousavi HZ, Khaligh A. Simple determination of amphetamine and methamphetamine in complicated matrices by filter-based emulsification microextraction followed by high-performance liquid chromatography. SEPARATION SCIENCE PLUS 2018. [DOI: 10.1002/sscp.201800092] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.1] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/24/2023]
Affiliation(s)
| | | | - Aisan Khaligh
- Department of Chemistry; Semnan University; Semnan Iran
| |
Collapse
|
14
|
Sajid M, Płotka-Wasylka J. Combined extraction and microextraction techniques: Recent trends and future perspectives. Trends Analyt Chem 2018. [DOI: 10.1016/j.trac.2018.03.013] [Citation(s) in RCA: 52] [Impact Index Per Article: 7.4] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/31/2022]
|
15
|
Chen Y, Lu X, Liu L, Wan D, Chen H, Zhou D, Sharma VK. Oxidation of β-blockers by birnessite: Kinetics, mechanism and effect of metal ions. CHEMOSPHERE 2018; 194:588-594. [PMID: 29241133 DOI: 10.1016/j.chemosphere.2017.12.015] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 09/26/2017] [Revised: 12/02/2017] [Accepted: 12/04/2017] [Indexed: 06/07/2023]
Abstract
Manganese dioxides are ubiquitous in natural waters, soils, and sediments and play an important role in oxidative transformation of organic pollutants. This work presents the kinetics of the oxidation of selected β-blockers, betaxolol, metoprolol, and atenolol by birnessite (δ-MnO2) as a function of concentration of the β-blocker, dosage of δ-MnO2, and solution pH. The values of pseudo-first-order rate constants (kobs) of β-blockers decreased in the order betaxolol > atenolol > metoprolol, which was positively correlated with their acid dissociation constants (Ka). Effect of series of metal ions (Fe3+, Cr3+, Al3+, Pb2+, Cu2+, Zn2+, Ni2+, Cd2+, Mg2+, and Ca2+) on the degradation of β-blockers by δ-MnO2 was systematically examined. All of these metal ions inhibited the oxidation reaction under the same constant ionic strength. The inhibition efficiency was positively correlated with the logarithm of stability constant of metal ions in aqueous solution (logKMeOH). By LC-ESI-MS/MS analyses, the oxidation of β-blockers primarily involved hydroxylation and cleavage of the parent molecules to the short branched chain compounds. An electron transfer mechanism for the oxidation of β-blockers by δ-MnO2 was proposed. The oxidation was initiated by the electron transfer from the nonbonding electrons on nitrogen (N-electrons) of β-blockers to δ-MnO2, followed by transformation of radical intermediates. These findings will help to understand the oxidation processes of β-blockers and predict the effect of metal ions on the removal of pollutants by δ-MnO2 in the environment.
Collapse
Affiliation(s)
- Yong Chen
- School of Environmental Science and Engineering, Huazhong University of Science and Technology, Wuhan, 430074, China.
| | - Xiye Lu
- School of Environmental Science and Engineering, Huazhong University of Science and Technology, Wuhan, 430074, China
| | - Lu Liu
- School of Environmental Science and Engineering, Huazhong University of Science and Technology, Wuhan, 430074, China
| | - Dong Wan
- School of Environmental Science and Engineering, Huazhong University of Science and Technology, Wuhan, 430074, China
| | - Huabin Chen
- Faculty of Material Science and Chemistry, China University of Geosciences, Wuhan, 430074, China
| | - Danna Zhou
- Faculty of Material Science and Chemistry, China University of Geosciences, Wuhan, 430074, China
| | - Virender K Sharma
- Program for the Environment and Sustainability, Department of Environmental and Occupational Health, School of Public Health, Texas A&M University, College Station, TX 77843, USA
| |
Collapse
|
16
|
Moghadam AG, Rajabi M, Asghari A. Efficient and relatively safe emulsification microextraction using a deep eutectic solvent for influential enrichment of trace main anti-depressant drugs from complicated samples. J Chromatogr B Analyt Technol Biomed Life Sci 2018; 1072:50-59. [DOI: 10.1016/j.jchromb.2017.09.042] [Citation(s) in RCA: 30] [Impact Index Per Article: 4.3] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/25/2017] [Revised: 09/23/2017] [Accepted: 09/26/2017] [Indexed: 12/19/2022]
|
17
|
Arghavani-Beydokhti S, Rajabi M, Asghari A. Combination of magnetic dispersive micro solid-phase extraction and supramolecular solvent-based microextraction followed by high-performance liquid chromatography for determination of trace amounts of cholesterol-lowering drugs in complicated matrices. Anal Bioanal Chem 2017; 409:4395-4407. [DOI: 10.1007/s00216-017-0383-x] [Citation(s) in RCA: 22] [Impact Index Per Article: 2.8] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/16/2017] [Revised: 04/06/2017] [Accepted: 04/26/2017] [Indexed: 11/28/2022]
|
18
|
Mirparizi E, Rajabi M, Bazregar M, Asghari A. Centrifugeless dispersive liquid-liquid microextraction based on salting-out phenomenon as an efficient method for determination of phenolic compounds in environmental samples. Anal Bioanal Chem 2017; 409:3007-3016. [DOI: 10.1007/s00216-017-0246-5] [Citation(s) in RCA: 16] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/25/2016] [Revised: 01/28/2017] [Accepted: 02/06/2017] [Indexed: 02/04/2023]
|