1
|
Sun X, Liu M, Liu H, Li L, Ding Y. A molecularly imprinted electrochemical aptasensor-based dual recognition elements for selective detection of dexamethasone. Talanta 2024; 277:126404. [PMID: 38879945 DOI: 10.1016/j.talanta.2024.126404] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/12/2024] [Revised: 05/18/2024] [Accepted: 06/09/2024] [Indexed: 06/18/2024]
Abstract
In this work, a novel molecularly imprinted electrochemical aptasensor (MIEAS) was developed for highly selective detection of dexamethasone (Dex) in natural water environment. Gold nanoparticles (AuNPs) modified by nitrogen doped molybdenum carbide-graphene (N-Mo2C-Gr) were employed as the supports, where N-Mo2C-Gr improved the conductivity of the electrode and provided a larger specific surface area to polymerize more active substances. Using Dex as template molecule, o-phenylenediamine (o-PD) as the chemical functional monomer and aptamer as the biofunctional monomer, a molecularly imprinted polymer (MIP) membrane with Dex specific recognition sites was formed by electropolymerization. Due to the synergistic effect of MIP and aptamers, the as-prepared MIEAS exhibited a decent linear relationship to Dex detection within a relatively wide range of 10-13 - 10-5 M, and the detection limit was 1.79 × 10-14 M. The recovery in actual water and tablet samples is satisfactory, which confirms the potential application prospects of this sensor in the determination of Dex.
Collapse
Affiliation(s)
- Xuyuan Sun
- Department of Chemistry, College of Sciences, Shanghai University, Shanghai, 200444, PR China
| | - Minmin Liu
- Institute for Sustainable Energy, College of Sciences, Shanghai University, Shanghai, 200444, PR China
| | - Hao Liu
- Department of Chemistry, College of Sciences, Shanghai University, Shanghai, 200444, PR China
| | - Li Li
- Department of Chemistry, College of Sciences, Shanghai University, Shanghai, 200444, PR China.
| | - Yaping Ding
- Department of Chemistry, College of Sciences, Shanghai University, Shanghai, 200444, PR China.
| |
Collapse
|
2
|
Abedi R, Raoof JB, Mohseni M, Bagheri Hashkavayi A. Sandwich-type electrochemical aptasensor based on hemin-graphite oxide as a signal label and rGO/MWCNTs/chitosan/carbon quantum dot modified electrode for sensitive detection of Acinetobacter baumannii bacteria. Anal Chim Acta 2024; 1303:342491. [PMID: 38609258 DOI: 10.1016/j.aca.2024.342491] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/17/2023] [Revised: 03/09/2024] [Accepted: 03/15/2024] [Indexed: 04/14/2024]
Abstract
Acinetobacter baumannii (A. baumannii) is a pathogenic bacterium that causes severe infections and its rapid and reliable diagnosis is essential for effective control and treatment. In this study, we present an electrochemical aptasensor based on a signal amplification strategy for the detection of A. baumannii, the high specificity and affinity of the aptamer for the target make it favorable for signal amplification. This allows for a highly sensitive and selective detection of the target. The aptasensor is based on a carbon screen-printed electrode (CSPE) that has been modified with a nanocomposite consisting of multi-walled carbon nanotubes (MWCNTs), reduced graphene oxide (rGO), chitosan (CS), and a synthesized carbon quantum dot (CQD) from CS. Additionally, the self-assembled aptamers were immobilized on hemin-graphite oxide (H-GO) as a signal probe. The composition of the nanocomposite (rGO-MWCNT/CS/CQD) provides high conductivity and stability, facilitating the efficient capture of A. baumannii onto the surface of the aptasensor. Also, aptamer immobilized on Hemin-graphite oxide (H-GO/Aptamer) was utilized as an electrochemical signal reporter probe by H reduction. This approach improved the detection sensitivity and the aptamer surface density for detecting A. baumannii. Furthermore, under optimized experimental conditions, the aptasensor was demonstrated to be capable of detecting A. baumannii with a linear range of (10 - 1 × 107 Colony-forming unit (CFU)/mL) and a limit of detection (LOD) of 1 CFU/mL (σ = 3). One of the key features of this aptasensor is its ability to distinguish between live and dead bacteria cells, which is very important and critical for clinical applications. In addition, we have successfully detected A. baumannii bacteria in healthy human serum and skim milk powder samples provided using the prepared electrochemical aptasensor. The functional groups present in the synthetic CQD, rGO-MWCNT, and chitosan facilitate biomolecule immobilization and enhance stability and activity. The fast electron-transfer kinetics and high conductivity of these materials contribute to improved sensitivity and selectivity. Furthermore, The H-GO/Aptamer composite's large surface area increases the number of immobilized secondary aptamers and enables a more stable structure. This large surface area also facilitates more H loading, leading to signal amplification.
Collapse
Affiliation(s)
- Rokhsareh Abedi
- Electroanalytical Chemistry Research Laboratory, Department of Analytical Chemistry, Faculty of Chemistry, University of Mazandaran, Babolsar, Iran
| | - Jahan Bakhsh Raoof
- Electroanalytical Chemistry Research Laboratory, Department of Analytical Chemistry, Faculty of Chemistry, University of Mazandaran, Babolsar, Iran.
| | - Mojtaba Mohseni
- Department of Microbiology, Faculty of Science, University of Mazandaran, Iran
| | - Ayemeh Bagheri Hashkavayi
- Department of Applied Physical Sciences, University of North Carolina- Chapel Hill, 1112 Murray Hall, CB#3050, Chapel Hill, NC, 27599-2100, USA
| |
Collapse
|
3
|
Küçük N, Kaya Ş, Şahin S, Çağlayan MO. Structural switching aptamer-based electrochemical sensor for mycotoxin patulin detection. Toxicon 2024; 239:107583. [PMID: 38141970 DOI: 10.1016/j.toxicon.2023.107583] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/02/2023] [Revised: 12/04/2023] [Accepted: 12/18/2023] [Indexed: 12/25/2023]
Abstract
In this study, an electrochemical and aptamer-based aptasensor was developed for the sensitive detection of patulin, a mycotoxin commonly found in fruits and fruit-based products. The aptasensor used an innovative structural switching signal-off platform for detecting patulin. The aptamer immobilization on screen-printed carbon electrodes was achieved through Au electrodeposition and thiol group (-SH) route. Response surface methodology was used to determine the optimal incubation times for the aptamer, blocking agent, and target molecule, which were found to be 180 min, 40 min, and 89 min, respectively. The response of the aptamer to different concentrations of patulin was measured using square wave voltammetry by exploiting the structural switching mechanism. The sensor response was determined by quantifying differences in the aptasensor's background current. The aptasensor exhibited a linear working range of 1-25 μM and a low detection limit of 3.56 ng/mL for patulin. The aptasensor's relative standard deviation and accuracy were determined to be 0.067 and 94.4%, respectively. A non-specific interaction was observed at low concentrations of two other mycotoxins, ochratoxin A and zearalenone. The interference from ochratoxin A in the measurements was below 10%. In real sample tests using apple juice, interference, particularly at low concentrations, had changed the recovery of patulin negatively with a significant effect on the structural switching behavior. Nevertheless, at a concentration of 25 ng/mL, the interference effect was eliminated, and the recovery standard deviation improved to 6.6%. The aptasensor's stability was evaluated over 10 days, and it demonstrated good performance, retaining 13.12% of its initial response. These findings demonstrate the potential of the developed electrochemical aptasensor for the sensitive detection of patulin in fruit-based products, with prospects for application in food safety and quality control.
Collapse
Affiliation(s)
- Netice Küçük
- Bilecik Seyh Edebali University, Department of Biotechnology, Bilecik, Turkey.
| | - Şevval Kaya
- School of Engineering, Lancaster University, Lancaster, LA1 4YW, UK.
| | - Samet Şahin
- School of Engineering, Lancaster University, Lancaster, LA1 4YW, UK; Bilecik Seyh Edebali University, Department of Bioengineering, Bilecik, Turkey.
| | | |
Collapse
|
4
|
Abedi R, Raoof JB, Mohseni M, Bagheri Hashkavayi A. Development of a label-free impedimetric aptasensor for the detection of Acinetobacter baumannii bacteria. Anal Biochem 2023; 679:115288. [PMID: 37619902 DOI: 10.1016/j.ab.2023.115288] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/13/2023] [Revised: 08/15/2023] [Accepted: 08/16/2023] [Indexed: 08/26/2023]
Abstract
Acinetobacter baumannii (A. baumannii) is responsible for various nosocomial infections, which is known as a clinically crucial opportunistic pathogen. Therefore, rapid detection of this pathogen is critical to prevent the spread of infection and appropriate treatment. Biological detection probes, such as aptamers and synthetic receptors can be used as diagnostic layers to detect bacteria. In this work, an electrochemical aptasensor was developed for the ultrasensitive detection of A. baumannii by electrochemical impedance spectroscopy (EIS). The aptamer was immobilized on the surface of a CSPE modified with the nanocomposite Fe3O4@SiO2@Glyoxal (Gly) for selective and label-free detection of A. baumannii. The charge transfers resistance (Rct) between redox couple [Fe(CN)63-/4-] and the surface of aptasensor in the Nyquist plot of EIS study was used as electroanalytical signal for detection and determination of A. baumannii. The obtained results showed that the constructed aptasensor could specifically detect A. baumannii in the concentration range from 1.0 × 103-1.0 × 108 Colony-forming unit (CFU)/mL and with a detection limit of 150 CFU/mL (S/N = 3). In addition to its sensitivity, the biosensor exhibits high selectivity over some other pathogens. Therefore, a simple, inexpensive, rapid, label-free, selective, and sensitive electrochemical aptasensor was developed to detect A. baumannii.
Collapse
Affiliation(s)
- Rokhsareh Abedi
- Electroanalytical Chemistry Research Laboratory, Department of Analytical Chemistry, Faculty of Chemistry, University of Mazandaran, Babolsar, Iran
| | - Jahan Bakhsh Raoof
- Electroanalytical Chemistry Research Laboratory, Department of Analytical Chemistry, Faculty of Chemistry, University of Mazandaran, Babolsar, Iran.
| | - Mojtaba Mohseni
- Department of Microbiology, Faculty of Science, University of Mazandaran, Iran
| | - Ayemeh Bagheri Hashkavayi
- Department of Electrical and Computer Engineering, North Carolina State University, Raleigh, NC, 27606, United States
| |
Collapse
|
5
|
Abedi R, Raoof JB, Mohseni M, Bagheri Hashkavayi A. A signal-off aptasensor for the determination of Acinetobacter baumannii by using methylene blue as an electrochemical probe. Mikrochim Acta 2023; 190:308. [PMID: 37466698 DOI: 10.1007/s00604-023-05901-0] [Citation(s) in RCA: 4] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/26/2023] [Accepted: 07/04/2023] [Indexed: 07/20/2023]
Abstract
An electrochemical aptasensor has been developed to detect Acinetobacter baumannii (A. baumannii). The proposed system was developed by modifying carbon screen-printed electrodes (CSPEs) with a synthesized MWCNT@Fe3O4@SiO2-Cl nanocomposite and then binding A. baumannii-specific aptamer using covalent immobilization on the modified electrode surface and the interaction of methylene blue (MB) with Apt as an electrochemical redox indicator. As a result of the incubation of the A. baumannii bacteria as a target on the proposed aptasensor, a cathodic peak current density (Jpc) of MB decreased due to the formation of the Apt-A. baumannii complex and MB being released from the immobilized Apt on the surface of the modified electrode. In addition to increasing the electron transfer kinetics, the nanocomposite provides a relatively stable matrix to improve the loading Apt sequence. The suggested aptasensor was demonstrated to be capable of detecting A. baumannii with a linear range of 10.0-1.0 × 107 colony-forming unit (CFU) mL-1 and a detection limit of 1 CFU mL-1 (S/N = 3) using differential pulse voltammetry (DPV) studies at a working potential of ~0.29 V and a scan rate of 100 mV s-1. The outcomes revealed that the aptasensor exhibited high A. baumannii detection sensitivity, stability, reproducibility, and specificity.
Collapse
Affiliation(s)
- Rokhsareh Abedi
- Electroanalytical Chemistry Research Laboratory, Department of Analytical Chemistry, Faculty of Chemistry, University of Mazandaran, Babolsar, Iran
| | - Jahan Bakhsh Raoof
- Electroanalytical Chemistry Research Laboratory, Department of Analytical Chemistry, Faculty of Chemistry, University of Mazandaran, Babolsar, Iran.
| | - Mojtaba Mohseni
- Department of Molecular and Cell Biology, University of Mazandaran, Babolsar, 47416-95447, Iran
| | - Ayemeh Bagheri Hashkavayi
- Department of Electrical and Computer Engineering, North Carolina State University, Raleigh, NC, 27606, USA
| |
Collapse
|
6
|
Mulyani DE, Maksum IP. Detection of Biomarker Using Aptasensors to Determine the Type of Diabetes. Diagnostics (Basel) 2023; 13:2035. [PMID: 37370930 DOI: 10.3390/diagnostics13122035] [Citation(s) in RCA: 3] [Impact Index Per Article: 1.5] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/08/2023] [Revised: 06/04/2023] [Accepted: 06/08/2023] [Indexed: 06/29/2023] Open
Abstract
Diabetes mellitus (DM) is a metabolic disorder characterized by elevated blood glucose levels. This disease is so serious that many experts refer to it as the "silent killer". The early detection of diabetes mellitus, whether type 1, type 2 or mitochondrial, is crucial because it can improve the success of treatment and the quality of life for patients. Aptamer-based biosensor diagnosis methods have been widely developed because they have high sensitivity and selectivity in detecting biomarkers of various diseases. Aptamers are short sequences of oligonucleotides or proteins that recognize specific ligands and bind to various target molecules, ranging from small ions to large proteins. They are promising diagnostic molecules due to their high sensitivity and selectivity, ease of modification, low toxicity, and high stability. This article aims to summarize the progress of detection methods, including detection principles, sensitivity, selectivity, and the performance of detection devices, to distinguish between types of diabetes mellitus using electrochemical aptasensors with biomarkers such as glucose, insulin, HbA1c, GHSA, and ATP.
Collapse
Affiliation(s)
- Dinda Exelsa Mulyani
- Department of Chemistry, Faculty of Mathematics and Natural Sciences, Universitas Padjadjaran, Sumedang 45363, Indonesia
| | - Iman Permana Maksum
- Department of Chemistry, Faculty of Mathematics and Natural Sciences, Universitas Padjadjaran, Sumedang 45363, Indonesia
| |
Collapse
|
7
|
Beiki T, Najafpour-Darzi G, Mohammadi M, Shakeri M, Boukherroub R. Fabrication of a novel electrochemical biosensor based on a molecular imprinted polymer-aptamer hybrid receptor for lysozyme determination. Anal Bioanal Chem 2023; 415:899-911. [PMID: 36544030 DOI: 10.1007/s00216-022-04487-5] [Citation(s) in RCA: 11] [Impact Index Per Article: 5.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/20/2022] [Revised: 11/19/2022] [Accepted: 12/13/2022] [Indexed: 12/24/2022]
Abstract
In this work, a novel, sensitive, and rapid electrochemical biosensor was employed to detect lysozyme (Lys) using a double receptor of molecular imprinted polymer (MIP)-aptamer. First, a glassy carbon electrode (GCE) was modified with a nanocomposite consisting of multi-wall carbon nanotubes (MWCNTs), nitrogen-doped carbon quantum dots (N-CQDs), and chitosan. Subsequently, aptamer (Apt)-Lys complex was immobilized on MWCNTs-N-CQDs-chitosan/GCE via binding between carboxyl groups present in the nanocomposite and the terminal amine groups of the aptamer. Following that, methylene blue monomer was electrochemically polymerized around the Apt-Lys complex on the MWCNTs-N-CQDs-chitosan/GCE surface. Finally, after the template removal, the remaining cavities along with the aptamers created a new hybrid receptor of MIP-aptamer. The MWCNTs-N-CQDs-chitosan nanocomposite could provide large amounts of carboxyl groups for binding to amino-functionalized aptamers, considerable electrical conductivity, and a high surface-to-volume ratio. These beneficial features facilitated the Apt-Lys complex immobilization and gave improved electrochemical signal. The obtained MIP-aptamer hybrid receptor allowed lysozyme determination even at concentrations as low as 4.26 fM within the functional range of 1 fM to 100 nM.
Collapse
Affiliation(s)
- Tavoos Beiki
- Biotechnology Research Laboratory, Department of Chemical Engineering, Babol Noshirvani University of Technology, Babol, 47148-71167, Iran
| | - Ghasem Najafpour-Darzi
- Biotechnology Research Laboratory, Department of Chemical Engineering, Babol Noshirvani University of Technology, Babol, 47148-71167, Iran.
| | - Maedeh Mohammadi
- Biotechnology Research Laboratory, Department of Chemical Engineering, Babol Noshirvani University of Technology, Babol, 47148-71167, Iran
| | - Mohsen Shakeri
- Department of Mechanical Engineering, Babol Noshirvani University of Technology, Babol, 47148-71167, Iran
| | - Rabah Boukherroub
- Univ. Lille, CNRS, Centrale Lille, Univ. Polytechnique Hauts-de-France, UMR 8520 - IEMN, F-59000, Lille, France
| |
Collapse
|
8
|
Yan H, He B, Xie L, Cao X. A label-free electrochemical aptasensor based on NH 2-MIL-235(Fe) for the sensitive detection of citrinin. ANALYTICAL METHODS : ADVANCING METHODS AND APPLICATIONS 2022; 14:3702-3708. [PMID: 36103596 DOI: 10.1039/d2ay01243j] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 06/15/2023]
Abstract
This study successfully developed a simple, specific, and ultrasensitive electrochemical aptasensor based on a label-free strategy for detecting citrinin (CIT). The NH2-Fe-MOF nanomaterial has a large specific surface area, good biocompatibility, a simple preparation method, and low synthesis cost, so it was chosen as the aptamer's loading platform to improve the detection performance of the sensor. When CIT is present, the aptamer will specifically bind to it with a conformational change that prevents electron transfer to the electrode surface. Based on this, CIT could be quantitatively detected by measuring the change of differential pulse voltammetric (DPV) responses of the [Fe(CN)6]3-/4- peak current. Under optimized experimental conditions, the proposed aptasensor showed a low detection limit of 4.52 × 10-11 g mL-1 and a wide linear range of 0.1 to 1 × 104 ng mL-1. Furthermore, the proposed aptasensor shows excellent selectivity, reliable stability, and significant potential for the ultrasensitive detection of CIT in practical applications.
Collapse
Affiliation(s)
- Haoyang Yan
- School of International Education, Henan University of Technology, Zhengzhou, Henan 450001, P. R. China
| | - Baoshan He
- School of Food Science and Technology, Henan University of Technology, Zhengzhou, Henan 450001, P. R. China
| | - Lingling Xie
- School of Environmental Engineering, Henan University of Technology, Zhengzhou, Henan 450001, PR China
| | - Xiaoyu Cao
- School of Chemistry and Chemical Engineering, Henan University of Technology, Zhengzhou, Henan 450001, P. R. China
| |
Collapse
|