1
|
Kolahi S, Tahamtan M, Sarvari M, Zarei D, Afsharzadeh M, Firouznia K, Yousem DM. Diagnostic Performance of TOF, 4D MRA, Arterial Spin-Labeling, and Susceptibility-Weighted Angiography Sequences in the Post-Radiosurgery Monitoring of Brain AVMs. AJNR Am J Neuroradiol 2025; 46:57-65. [PMID: 39025641 PMCID: PMC11735419 DOI: 10.3174/ajnr.a8420] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/21/2024] [Accepted: 07/14/2024] [Indexed: 07/20/2024]
Abstract
BACKGROUND Brain AVMs are congenital anomalies of the cerebrovascular system, often discovered incidentally or through symptomatic presentations such as intracranial hemorrhage, seizure, headache, or neurologic deficits. Various treatment modalities exist for AVMs, including radiosurgery, a treatment technique that is noninvasive and efficient. Accurate imaging is crucial for risk assessment, treatment planning, and monitoring of these patients before and after radiosurgery. PURPOSE Currently, DSA is the preferred imaging technique. Despite its efficacy, DSA is notably invasive, presenting inherent risks to the patients. This systematic review and meta-analysis aimed to evaluate the efficacy of MRI sequences for monitoring brain AVMs after radiosurgery. DATA SOURCE We performed a comprehensive search of PubMed, Scopus, Web of Science, and EMBASE databases and a methodologic quality assessment with the QUADAS-2 checklist diagnostic test accuracy. STUDY SELECTION According to the Preferred Reporting Items for Systematic Reviews and Meta-Analyses (PRISMA) guidelines, 3,220 abstracts were screened, 98 articles were reviewed in full text, and 14 articles met the inclusion criteria. DATA ANALYSIS We used the bivariate random-effects meta-analysis model with STATA/MP 17 software for data analysis. DATA SYNTHESIS No publication bias was detected. Fourteen studies were eligible for qualitative and quantitative analysis. MRI offers high sensitivity (85%) and specificity (99%) in detecting residual AVMs. Different MRI sequences, including 3D TOF-MRA, 4D MRA, and arterial spin-labeling (ASL) demonstrated varying diagnostic accuracies with areas under the curve of 0.92, 0.97, and 0.96, respectively. 4D MRA had a sensitivity of 72% and specificity of 99%, ASL showed a sensitivity of 90% and specificity of 92%, while 3D TOF-MRA had 90% sensitivity and 87% specificity. LIMITATIONS Meta-regression did not fully explain the sources of heterogeneity. Only 1 study assessed the susceptibility-weighted angiography (SWAN) method, and most studies involved small participant groups with varied MR techniques and sequences. Additionally, the retrospective nature of most studies may introduce bias, warranting cautious interpretation of the results. CONCLUSIONS MRI sequences show acceptable diagnostic performance in postradiosurgery monitoring of brain AVMs, with ASL and 4D MRA showing acceptable diagnostic accuracy. Combining different MRI sequences may further enhance diagnostic reliability. However, further investigation is needed to assess whether MRI sequences can serve as a feasible substitute for DSA, considering their risk-benefit profile, with the potential to establish them as the recommended standard.
Collapse
Affiliation(s)
- Shahriar Kolahi
- From the Advanced Diagnostic and Interventional Radiology Research Center (S.K., M.T., M.S., D.Z., M.A., K.F.), Department of Radiology, Imam Khomeini Hospital, Tehran University of Medical Sciences, Tehran, Iran
| | - Mohammadreza Tahamtan
- From the Advanced Diagnostic and Interventional Radiology Research Center (S.K., M.T., M.S., D.Z., M.A., K.F.), Department of Radiology, Imam Khomeini Hospital, Tehran University of Medical Sciences, Tehran, Iran
| | - Masoumeh Sarvari
- From the Advanced Diagnostic and Interventional Radiology Research Center (S.K., M.T., M.S., D.Z., M.A., K.F.), Department of Radiology, Imam Khomeini Hospital, Tehran University of Medical Sciences, Tehran, Iran
- Endocrinology and Metabolism Research Center (M.S.), Endocrinology and Metabolism Clinical Sciences Institute, Tehran University of Medical Sciences, Tehran, Iran
| | - Diana Zarei
- From the Advanced Diagnostic and Interventional Radiology Research Center (S.K., M.T., M.S., D.Z., M.A., K.F.), Department of Radiology, Imam Khomeini Hospital, Tehran University of Medical Sciences, Tehran, Iran
| | - Mahshad Afsharzadeh
- From the Advanced Diagnostic and Interventional Radiology Research Center (S.K., M.T., M.S., D.Z., M.A., K.F.), Department of Radiology, Imam Khomeini Hospital, Tehran University of Medical Sciences, Tehran, Iran
- Isfahan Neurosciences Research Center (M.A.), Isfahan University of Medical Sciences, Isfahan, Iran
| | - Kavous Firouznia
- From the Advanced Diagnostic and Interventional Radiology Research Center (S.K., M.T., M.S., D.Z., M.A., K.F.), Department of Radiology, Imam Khomeini Hospital, Tehran University of Medical Sciences, Tehran, Iran
| | - David M Yousem
- Office of Faculty (D.M.Y.), Johns Hopkins University School of Medicine, Baltimore, Maryland
- Department of Radiology (D.M.Y.), Johns Hopkins University School of Medicine (JHUSOM), Baltimore, Maryland
| |
Collapse
|
2
|
Das S, Kasher P, Waqar M, Parry-Jones A, Patel H. Reporting of angiographic studies in patients diagnosed with a cerebral arteriovenous malformation: a systematic review. F1000Res 2024; 12:1252. [PMID: 39931157 PMCID: PMC11809685 DOI: 10.12688/f1000research.139256.3] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Figures] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Accepted: 11/21/2024] [Indexed: 02/13/2025] Open
Abstract
A cerebral arteriovenous malformation (cAVM) is an abnormal tangle of cerebral blood vessels. The consensus document by the Joint Writing Group (JWG) highlighted which cAVM features should be recorded. Subsequent publications have reported cAVM angioarchitecture, but it is unknown if all followed the JWG recommendations. The aim of this systematic review was to describe use of the JWG guidelines. A database search, using the PRISMA checklist, was performed. We describe the proportion of publications that used JWG reporting standards, which standards were used, whether the definitions used differed from the JWG, or if any additional angiographic features were reported. Out of 4306 articles identified, 105 were selected, and a further 114 from other sources. Thirty-three studies (33/219; 15%) specifically referred to using JWG standards. Since the JWG publication, few studies have used their standards to report cAVMs. This implies that the angioarchitecture of cAVMs are not routinely fully described.
Collapse
Affiliation(s)
- Suparna Das
- The University of Manchester, Manchester, England, UK
| | - Paul Kasher
- The University of Manchester, Manchester, England, UK
| | - Mueez Waqar
- The University of Manchester, Manchester, England, UK
| | | | - Hiren Patel
- The University of Manchester, Manchester, England, UK
| |
Collapse
|
3
|
Togao O, Obara M, Yamashita K, Kikuchi K, Wada T, Murazaki H, Arimura K, Nishimura A, Horie N, van de Ven K, Van Cauteren M, Ishigami K. Arterial Spin Labeling-Based MR Angiography for Cerebrovascular Diseases: Principles and Clinical Applications. J Magn Reson Imaging 2024; 60:1305-1324. [PMID: 37937684 DOI: 10.1002/jmri.29119] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/17/2023] [Revised: 10/23/2023] [Accepted: 10/23/2023] [Indexed: 11/09/2023] Open
Abstract
Arterial spin labeling (ASL) is a noninvasive imaging technique that labels the proton spins in arterial blood and uses them as endogenous tracers. Brain perfusion imaging with ASL is becoming increasingly common in clinical practice, and clinical applications of ASL for intracranial magnetic resonance angiography (MRA) have also been demonstrated. Unlike computed tomography (CT) angiography and cerebral angiography, ASL-based MRA does not require contrast agents. ASL-based MRA overcomes most of the disadvantages of time-of-flight (TOF) MRA. Several schemes have been developed for ASL-based MRA; the most common method has been pulsed ASL, but more recently pseudo-continuous ASL, which provides a higher signal-to-noise ratio (SNR), has been used more frequently. New methods that have been developed include direct intracranial labeling methods such as velocity-selective ASL and acceleration-selective ASL. MRA using an extremely short echo time (eg, silent MRA) or ultrashort echo-time (TE) MRA can suppress metal susceptibility artifacts and is ideal for patients with a metallic device implanted in a cerebral vessel. Vessel-selective 4D ASL MRA can provide digital subtraction angiography (DSA)-like images. This review highlights the principles, clinical applications, and characteristics of various ASL-based MRA techniques. LEVEL OF EVIDENCE: 5 TECHNICAL EFFICACY: Stage 2.
Collapse
Affiliation(s)
- Osamu Togao
- Department of Molecular Imaging & Diagnosis, Graduate School of Medical Sciences, Kyushu University, Fukuoka, Japan
| | | | - Koji Yamashita
- Department of Clinical Radiology, Graduate School of Medical Sciences, Kyushu University, Fukuoka, Japan
| | - Kazufumi Kikuchi
- Department of Molecular Imaging & Diagnosis, Graduate School of Medical Sciences, Kyushu University, Fukuoka, Japan
| | - Tatsuhiro Wada
- Division of Radiology, Department of Medical Technology, Kyushu University Hospital, Fukuoka, Japan
| | - Hiroo Murazaki
- Division of Radiology, Department of Medical Technology, Kyushu University Hospital, Fukuoka, Japan
| | - Koichi Arimura
- Department of Neurosurgery, Graduate School of Medical Sciences, Kyushu University, Fukuoka, Japan
| | - Ataru Nishimura
- Department of Neurosurgery, Graduate School of Medical Sciences, Kyushu University, Fukuoka, Japan
| | - Nobutaka Horie
- Department of Neurosurgery, Graduate School of Biomedical and Health Sciences, Hiroshima University, Hiroshima, Japan
| | | | | | - Kousei Ishigami
- Department of Clinical Radiology, Graduate School of Medical Sciences, Kyushu University, Fukuoka, Japan
| |
Collapse
|
4
|
Hallak H, Aljarayhi S, Abou-Al-Shaar H, Martini M, Michealcheck C, Elarjani T, Bin-Alamer O, Naik A, Aldahash H, Brinjikji W, Lawton M, Alotaibi N. Diagnostic accuracy of arterial spin labeling MR imaging in detecting cerebral arteriovenous malformations: a systematic review and meta-analysis. Neurosurg Rev 2024; 47:492. [PMID: 39190141 DOI: 10.1007/s10143-024-02659-8] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/24/2023] [Revised: 07/28/2024] [Accepted: 08/05/2024] [Indexed: 08/28/2024]
Abstract
Diagnostic accuracy of arteriovenous malformations (AVMs) is imperative for delineating management. The current standard is digital subtraction angiography (DSA). Arterial spin labeling (ASL) is an understudied noninvasive, non-contrast technique that allows angioarchitecture visualization and additionally quantifies cortical and AVM cerebral blood flow and hemodynamics. This meta-analysis aims to compare ASL and DSA imaging in detecting and characterizing cerebral AVMs. EMBASE, Medline, Scopus, and Cochrane databases were queried from inception to July 2022 for reports of AVMs evaluated by DSA and ASL imaging. Fourteen studies with 278 patients evaluated using DSA and ASL imaging prior to intervention were included; pCASL in 11 studies (n = 239, 85.37%) and PASL in three studies (n = 41, 14.64%). The overall AVM detection rate on ASL was 99% (CI 97-100%); subgroup analysis revealed no difference between pCASL vs. PASL (99%; CI 96-100% vs. 100%; CI 95-100% respectively, p = 0.42). The correlation value comparing ASL and DSA nidus size was 0.99. DSA and ASL intermodality agreement Cohen's k factor for Spetzler Martin Grading (SMG) was reported at a median of 0.98 (IQR 0.73-0.1), with a 1.0 agreement on SMG classification. A median of 25 arteries were detected by DSA (IQR 14.5-27), vs. 25 by ASL (IQR 14.5-27.5) at a median 0.92 k factor. ASL provides angioarchitectural visualization noninferior to DSA and additionally quantifies CBF. Our study suggests that ASL should be considered in the detection of AVMs, especially in patients with contrast contraindications or apprehension towards an invasive assessment.
Collapse
Affiliation(s)
- Hana Hallak
- Department of Neurological Surgery, King Faisal Specialist Hospital, Riyadh, Saudi Arabia.
| | - Salwa Aljarayhi
- Department of Neurological Surgery, King Faisal Specialist Hospital, Riyadh, Saudi Arabia
| | - Hussam Abou-Al-Shaar
- Department of Neurological Surgery, University of Pittsburgh Medical Center, Pittsburgh, PA, USA
| | - Michael Martini
- Department of Neurological Surgery, Mayo Clinic, Rochester, MN, USA
| | | | - Turki Elarjani
- Department of Neurological Surgery, University of Miami, Miami, FL, USA
| | - Othman Bin-Alamer
- Department of Neurological Surgery, University of Pittsburgh Medical Center, Pittsburgh, PA, USA
| | - Anant Naik
- Department of Neurological Surgery, Barrow Neurologic Institute, Phoenix, AZ, USA
| | - Homoud Aldahash
- Department of Neurological Surgery, University of Pittsburgh Medical Center, Pittsburgh, PA, USA
| | - Waleed Brinjikji
- Department of Neurological Surgery, King Faisal Specialist Hospital, Riyadh, Saudi Arabia
| | - Michael Lawton
- Department of Neurological Surgery, Barrow Neurologic Institute, Phoenix, AZ, USA
| | - Naif Alotaibi
- Department of Neurologic Surgery, King Fahad Medical City, Riyadh, Saudi Arabia
| |
Collapse
|
5
|
Jagadeesan B, Tariq F, Nada A, Bhatti IA, Masood K, Siddiq F. Principles Behind 4D Time-Resolved MRA/Dynamic MRA in Neurovascular Imaging. Semin Roentgenol 2024; 59:191-202. [PMID: 38880517 DOI: 10.1053/j.ro.2024.02.006] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/29/2024] [Accepted: 02/28/2024] [Indexed: 06/18/2024]
Affiliation(s)
- Bharathi Jagadeesan
- Departments of Radiology, Neurology and Neurosurgery, University of Minnesota, Minneapolis, MN.
| | - Farzana Tariq
- Departments of Neurosurgery and Radiology, University of Missouri, Columbia, MO
| | - Ayman Nada
- Departments of Neurosurgery and Radiology, University of Missouri, Columbia, MO
| | - Ibrahim A Bhatti
- Departments of Neurosurgery and Radiology, University of Missouri, Columbia, MO
| | - Kamran Masood
- Departments of Radiology, Neurology and Neurosurgery, University of Minnesota, Minneapolis, MN
| | - Farhan Siddiq
- Departments of Neurosurgery and Radiology, University of Missouri, Columbia, MO
| |
Collapse
|
6
|
Kitajima M, Uetani H. Arterial Spin Labeling for Pediatric Central Nervous System Diseases: Techniques and Clinical Applications. Magn Reson Med Sci 2023; 22:27-43. [PMID: 35321984 PMCID: PMC9849418 DOI: 10.2463/mrms.rev.2021-0118] [Citation(s) in RCA: 11] [Impact Index Per Article: 5.5] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/31/2021] [Accepted: 01/12/2022] [Indexed: 01/28/2023] Open
Abstract
Dynamic susceptibility contrast (DSC) and arterial spin labeling (ASL) are techniques used to evaluate brain perfusion using MRI. DSC requires dynamic image acquisition with a rapid administration of gadolinium-based contrast agent. In contrast, ASL obtains brain perfusion information using magnetically labeled blood water as an endogenous tracer. For the evaluation of brain perfusion in pediatric neurological diseases, ASL has a significant advantage compared to DSC, CT, and single-photon emission CT/positron emission tomography because of the lack of radiation exposure and contrast agent administration. However, in ASL, optimization of several parameters, including the type of labeling, image acquisition, background suppression, and postlabeling delay, is required, because they have a significant effect on the quantification of cerebral blood flow (CBF).In this article, we first review recent technical developments of ASL and age-dependent physiological characteristics in pediatric brain perfusion. We then review the clinical implementation of ASL in pediatric neurological diseases, including vascular diseases, brain tumors, acute encephalopathy with biphasic seizure and late reduced diffusion (AESD), and migraine. In moyamoya disease, ASL can be used for brain perfusion and vessel assessment in pre- and post-treatment. In arteriovenous malformations, ASL is sensitive to detect small degrees of shunt. Furthermore, in vascular diseases, the implementation of ASL-based time-resolved MR angiography is described. In neoplasms, ASL-derived CBF has a high diagnostic accuracy for differentiation between low- and high-grade pediatric brain tumors. In AESD and migraine, ASL may allow for accurate early diagnosis and provide pathophysiological information.
Collapse
Affiliation(s)
- Mika Kitajima
- Department of Medical Imaging Sciences, Faculty of Life Sciences, Kumamoto University, Kumamoto, Kumamoto, Japan
| | - Hiroyuki Uetani
- Diagnostic Radiology, Faculty of Life Sciences, Kumamoto University, Kumamoto, Kumamoto, Japan
| |
Collapse
|
7
|
Sakata A, Sakamoto R, Fushimi Y, Nakajima S, Hinoda T, Oshima S, Wetzl J, Schmidt M, Okawa M, Yoshida K, Miyamoto S, Nakamoto Y. Low-dose contrast-enhanced time-resolved angiography with stochastic trajectories with iterative reconstruction (IT-TWIST-MRA) in brain arteriovenous shunt. Eur Radiol 2022; 32:5392-5401. [PMID: 35298680 DOI: 10.1007/s00330-022-08678-7] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/29/2021] [Revised: 02/06/2022] [Accepted: 02/17/2022] [Indexed: 11/28/2022]
Abstract
OBJECTIVES To assess the feasibility of low-dose contrast-enhanced four-dimensional (4D) time-resolved angiography with stochastic trajectories (TWIST) with iterative reconstruction (hereafter IT-TWIST-MRA) covering the whole brain and to compare IT-TWIST-MRA and TWIST-MRA with reference to digital subtraction angiography (DSA) in the evaluation of arteriovenous shunts (AVS). METHODS Institutional Review Board approval was obtained for this observational study, and the requirement for written informed consent was waived. Twenty-nine patients with known AVS underwent TWIST-MRA on a 3-T MRI scanner, using low-dose injection (0.02 mmol/kg) of gadolinium-based contrast agent (GBCA) with each of Fourier and iterative reconstruction between September 2016 and October 2019. Visual evaluation of image quality was conducted for delineation of (a) the normal cerebral arteries and veins and (b) AVS feeder, shunt, and drainer vessels. Region-of-interest evaluation was conducted to evaluate bolus sharpness and baseline signal fluctuation in the signal intensity of the cerebral vessels. We compared the detection of AVS between TWIST-MRA and IT-TWIST-MRA. The paired-samples Wilcoxon test was used to test the differences between TWIST-MRA and IT-TWIST-MRA. RESULTS Visualization scores for normal vasculature and AVS angioarchitecture were significantly better for images produced using IT-TWIST-MRA than those using TWIST-MRA. Peak signal and the enhancement slope of the time-intensity curve were significantly higher for IT-TWIST-MRA than for TWIST-MRA, except for the superior sagittal sinus (SSS). Baseline intensity fluctuation was significantly lower for IT-TWIST-MRA than for TWIST, except for SSS. CONCLUSIONS IT-TWIST-MRA yields clinically feasible 4D MR-DSA images and delineates AVS even with low-dose GBCA. KEY POINTS • Iterative reconstruction significantly improves the image quality of TWIST-MRA covering the whole brain. • The short temporal footprint and denoising effect of iterative reconstruction enhances the quality of 4D-MRA. • IT-TWIST-MRA yields clinically feasible images of AVS with low-dose GBCA.
Collapse
Affiliation(s)
- Akihiko Sakata
- Department of Diagnostic Imaging and Nuclear Medicine, Graduate School of Medicine, Kyoto University, 54 Shogoin Kawahara-cho, Sakyo-ku, Kyoto, 606-8507, Japan
| | - Ryo Sakamoto
- Department of Diagnostic Imaging and Nuclear Medicine, Graduate School of Medicine, Kyoto University, 54 Shogoin Kawahara-cho, Sakyo-ku, Kyoto, 606-8507, Japan
| | - Yasutaka Fushimi
- Department of Diagnostic Imaging and Nuclear Medicine, Graduate School of Medicine, Kyoto University, 54 Shogoin Kawahara-cho, Sakyo-ku, Kyoto, 606-8507, Japan.
| | - Satoshi Nakajima
- Department of Diagnostic Imaging and Nuclear Medicine, Graduate School of Medicine, Kyoto University, 54 Shogoin Kawahara-cho, Sakyo-ku, Kyoto, 606-8507, Japan
| | - Takuya Hinoda
- Department of Diagnostic Imaging and Nuclear Medicine, Graduate School of Medicine, Kyoto University, 54 Shogoin Kawahara-cho, Sakyo-ku, Kyoto, 606-8507, Japan
| | - Sonoko Oshima
- Department of Diagnostic Imaging and Nuclear Medicine, Graduate School of Medicine, Kyoto University, 54 Shogoin Kawahara-cho, Sakyo-ku, Kyoto, 606-8507, Japan
| | - Jens Wetzl
- Siemens Healthcare GmbH, Allee am Roethelheimpark 2, 91052, Erlangen, Germany
| | - Michaela Schmidt
- Siemens Healthcare GmbH, Allee am Roethelheimpark 2, 91052, Erlangen, Germany
| | - Masakazu Okawa
- Department of Neurosurgery, Graduate School of Medicine, Kyoto University, Kyoto, 606-8507, Japan
| | - Kazumichi Yoshida
- Department of Neurosurgery, Graduate School of Medicine, Kyoto University, Kyoto, 606-8507, Japan
| | - Susumu Miyamoto
- Department of Neurosurgery, Graduate School of Medicine, Kyoto University, Kyoto, 606-8507, Japan
| | - Yuji Nakamoto
- Department of Diagnostic Imaging and Nuclear Medicine, Graduate School of Medicine, Kyoto University, 54 Shogoin Kawahara-cho, Sakyo-ku, Kyoto, 606-8507, Japan
| |
Collapse
|
8
|
Togao O, Obara M, Kikuchi K, Helle M, Arimura K, Nishimura A, Wada T, Murazaki H, Van Cauteren M, Hiwatashi A, Ishigami K. Vessel-Selective 4D-MRA Using Superselective Pseudocontinuous Arterial Spin-Labeling with Keyhole and View-Sharing for Visualizing Intracranial Dural AVFs. AJNR Am J Neuroradiol 2022; 43:368-375. [PMID: 35241425 PMCID: PMC8910818 DOI: 10.3174/ajnr.a7426] [Citation(s) in RCA: 6] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/22/2021] [Accepted: 12/11/2021] [Indexed: 11/07/2022]
Abstract
BACKGROUND AND PURPOSE An accurate assessment of the hemodynamics of an intracranial dural AVF is necessary for treatment planning. We aimed to investigate the utility of 4D-MRA based on superselective pseudocontinuous arterial spin-labeling with CENTRA-keyhole and view-sharing (4D-S-PACK) for the vessel-selective visualization of intracranial dural AVFs. MATERIALS AND METHODS We retrospectively analyzed the images of 21 patients (12 men and 9 women; mean age, 62.2 [SD,19.2] years) with intracranial dural AVFs, each of whom was imaged with DSA, 4D-S-PACK, and nonselective 4D-MRA based on pseudocontinuous arterial spin-labeling combined with CENTRA-keyhole and view-sharing (4D-PACK). The shunt location, venous drainage patterns, feeding artery identification, and Borden classification were evaluated by 2 observers using both MRA methods on separate occasions. Vessel selectivity was evaluated on 4D-S-PACK. RESULTS Shunt locations were correctly evaluated in all 21 patients by both observers on both MRA methods. With 4D-S-PACK, observers 1 and 2 detected 76 (80.0%, P < .001) and 73 (76.8%, P < .001) feeding arteries of the 95 feeding arteries identified on DSA but only 39 (41.1%) and 46 (48.4%) feeding arteries with nonselective 4D-PACK, respectively. Both observers correctly identified 10 of the 11 patients with cortical venous reflux confirmed by DSA with both 4D-S-PACK and 4D-PACK (sensitivity = 90.9%, specificity = 90.9% for each method), and they made accurate Borden classifications in 20 of the 21 patients (95.2%) on both MRA methods. Of the 84 vessel territories examined, vessel selectivity was graded 3 or 4 in 73 (91.2%) and 66 (88.0%) territories by observers 1 and 2, respectively. CONCLUSIONS 4D-S-PACK is useful for the identification of feeding arteries and accurate classifications of intracranial dural AVFs and can be a useful noninvasive clinical tool.
Collapse
Affiliation(s)
- O. Togao
- From the Departments of Molecular Imaging & Diagnosis (O.T.)
| | - M. Obara
- Philips Japan (M.O., M.V.C.), Tokyo, Japan
| | | | - M. Helle
- Philips Research (M.H.), Hamburg, Germany
| | - K. Arimura
- Neurosurgery (K.A., A.N.), Graduate School of Medical Sciences, Kyushu University, Fukuoka, Japan
| | - A. Nishimura
- Neurosurgery (K.A., A.N.), Graduate School of Medical Sciences, Kyushu University, Fukuoka, Japan
| | - T. Wada
- Division of Radiology (T.W., H.M.), Department of Medical Technology, Kyushu University Hospital, Fukuoka, Japan
| | - H. Murazaki
- Division of Radiology (T.W., H.M.), Department of Medical Technology, Kyushu University Hospital, Fukuoka, Japan
| | | | | | | |
Collapse
|
9
|
Evaluation of cerebral arteriovenous shunts: a comparison of parallel imaging time-of-flight magnetic resonance angiography (TOF-MRA) and compressed sensing TOF-MRA to digital subtraction angiography. Neuroradiology 2020; 63:879-887. [PMID: 33063222 DOI: 10.1007/s00234-020-02581-y] [Citation(s) in RCA: 11] [Impact Index Per Article: 2.2] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/27/2020] [Accepted: 10/06/2020] [Indexed: 10/23/2022]
Abstract
PURPOSE Time-of-flight (TOF)-MR angiography (MRA) is an important imaging sequence for the surveillance and analysis of cerebral arteriovenous shunt (AVS), including arteriovenous malformation (AVM) and arteriovenous fistula (AVF). However, this technique has the disadvantage of a relatively long scan time. The aim of this study was to compare diagnostic accuracy between compressed sensing (CS)-TOF and conventional parallel imaging (PI)-TOF-MRA for detecting and characterizing AVS. METHODS This study was approved by the institutional review board for human studies. Participants comprised 56 patients who underwent both CS-TOF-MRA and PI-TOF-MRA on a 3-T MR unit with or without cerebral AVS between June 2016 and September 2018. Imaging parameters for both sequences were almost identical, except the acceleration factor of 3× for PI-TOF-MRA and 6.5× for CS-TOF-MRA, and the scan time of 5 min 19 s for PI-TOF-MRA and 2 min 26 s for CS-TOF-MRA. Two neuroradiologists assessed the accuracy of AVS detection on each sequence and analyzed AVS angioarchitecture. Concordance between CS-TOF, PI-TOF, and digital subtraction angiography was calculated using unweighted and weighted kappa statistics. RESULTS Both CS-TOF-MRA and PI-TOF-MRA yielded excellent sensitivity and specificity for detecting intracranial AVS (reviewer 1, 97.3%, 94.7%; reviewer 2, 100%, 100%, respectively). Interrater agreement on the angioarchitectural features of intracranial AVS on CS-MRA and PI-MRA was moderate to good. CONCLUSION The diagnostic performance of CS-TOF-MRA is comparable to that of PI-TOF-MRA in detecting and classifying AVS with a reduced scan time under 2.5 min.
Collapse
|
10
|
Fu Q, Liu DX, Zhang XY, Deng XB, Zheng CS. Pointwise encoding time reduction with radial acquisition in subtraction-based magnetic resonance angiography to assess saccular unruptured intracranial aneurysms at 3 Tesla. Neuroradiology 2020; 63:189-199. [PMID: 32794074 DOI: 10.1007/s00234-020-02512-x] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.6] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/01/2020] [Accepted: 08/02/2020] [Indexed: 10/23/2022]
Abstract
PURPOSE To investigate the clinical utility of pointwise encoding time reduction with radial acquisition in subtraction-based magnetic resonance angiography (PETRA-MRA) and time-of-flight magnetic resonance angiography (TOF-MRA) to evaluate saccular unruptured intracranial aneurysms (UIAs). METHODS A total of 49 patients with 54 TOF-MRA-identified saccular UIAs were enrolled. The morphologic parameters, contrast-to-noise-ratios (CNRs), and sharpness of aneurysms were measured using PETRA-MRA and TOF-MRA. Two radiologists independently evaluated subjective image scores, focusing on aneurysm signal homogeneities and sharpness depictions using a 4-point scale: 4, excellent; 3, good; 2, poor; 1, not assessable. PETRA-MRA and TOF-MRA acoustic noises were measured. RESULTS All aneurysms were detected with PETRA-MRA. The morphologic parameters of 15 patients evaluated with PETRA-MRA were more closely correlated with those receiving computed tomography angiography over those receiving TOF-MRA. No significant differences between PETRA-MRA and TOF-MRA parameters were seen in the 54 UIAs (p > 0.10), excluding those with inflow angles (p < 0.05). In four patients with inflow angles on PETRA-MRA, the angles were more closely related to those of digital subtraction angiography than those of TOF-MRA. CNRs between TOF-MRA and PETRA-MRA were comparable (p = 0.068), and PETRA-MRA sharpness values and subjective image scores were significantly higher than those of TOF-MRA (p < 0.001). Inter-observer agreements were excellent for both PETRA-MRA and TOF-MRA (intraclass correlation coefficients were 0.90 and 0.97, respectively). The acoustic noise levels of PETRA-MRA were much lower than those of TOF-MRA (59 vs.73 dB, p < 0.01). CONCLUSIONS PETRA-MRA, with better visualization of aneurysms and lower acoustic noise levels than TOF-MRA, showed a superior diagnostic performance for depicting saccular UIAs.
Collapse
Affiliation(s)
- Qing Fu
- Department of Radiology, Union Hospital, Tongji Medical College, Huazhong University of Science and Technology, 1277 Jiefang Avenue, Wuhan, 430022, People's Republic of China.,Hubei Province Key Laboratory of Molecular Imaging, Wuhan, 430022, People's Republic of China
| | - Ding-Xi Liu
- Department of Radiology, Union Hospital, Tongji Medical College, Huazhong University of Science and Technology, 1277 Jiefang Avenue, Wuhan, 430022, People's Republic of China.,Hubei Province Key Laboratory of Molecular Imaging, Wuhan, 430022, People's Republic of China
| | - Xiao-Yong Zhang
- MR Collaborations, Siemens Healthcare Ltd, Shenzhen, 518000, People's Republic of China
| | - Xian-Bo Deng
- Department of Radiology, Union Hospital, Tongji Medical College, Huazhong University of Science and Technology, 1277 Jiefang Avenue, Wuhan, 430022, People's Republic of China.,Hubei Province Key Laboratory of Molecular Imaging, Wuhan, 430022, People's Republic of China
| | - Chuan-Sheng Zheng
- Department of Radiology, Union Hospital, Tongji Medical College, Huazhong University of Science and Technology, 1277 Jiefang Avenue, Wuhan, 430022, People's Republic of China. .,Hubei Province Key Laboratory of Molecular Imaging, Wuhan, 430022, People's Republic of China.
| |
Collapse
|
11
|
Togao O, Obara M, Helle M, Yamashita K, Kikuchi K, Momosaka D, Kikuchi Y, Nishimura A, Arimura K, Wada T, Murazaki H, Iihara K, Van Cauteren M, Hiwatashi A. Vessel-selective 4D-MR angiography using super-selective pseudo-continuous arterial spin labeling may be a useful tool for assessing brain AVM hemodynamics. Eur Radiol 2020; 30:6452-6463. [PMID: 32696254 DOI: 10.1007/s00330-020-07057-4] [Citation(s) in RCA: 22] [Impact Index Per Article: 4.4] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/14/2020] [Revised: 04/04/2020] [Accepted: 06/30/2020] [Indexed: 12/17/2022]
Abstract
OBJECTIVES To evaluate the usefulness of 4D-MR angiography based on super-selective pseudo-continuous ASL combined with keyhole and view-sharing (4D-S-PACK) for vessel-selective visualization and to examine the ability of this technique to visualize brain arteriovenous malformations (AVMs). METHODS In this retrospective study, 15 patients (ten men and five women, mean age 44.0 ± 16.9 years) with brain AVMs were enrolled. All patients were imaged with 4D-PACK (non-selective), 4D-S-PACK, and digital subtraction angiography (DSA). Observers evaluated vessel selectivity, identification of feeding arteries and venous drainage patterns, visualization scores, and contrast-to-noise ratio (CNR) for each AVM component. Measurements were compared between the MR methods. RESULTS Vessel selectivity was graded 4 in 43/45 (95.6%, observer 1) and 42/45 (93.3%, observer 2) territories and graded 3 in two (observer 1) and three (observer 2) territories. The sensitivity and specificity for identification of feeding arteries for both observers was 88.9% and 100% on 4D-PACK, and 100% and 100% on 4D-S-PACK, respectively. For venous drainage, the sensitivity and specificity was 100% on both methods for observer 1. The sensitivity and specificity for observer 2 was 94.4% and 83.3% on 4D-PACK, and 94.4% and 91.7% on 4D-S-PACK, respectively. The CNRs at the timepoint of 1600 ms were slightly lower in 4D-S-PACK than in 4D-PACK for all AVM components (Feeding artery, p = .02; nidus, p = .001; and draining artery, p = .02). The visualization scores for both observers were not significantly different between 4D-PACK and 4D-S-PACK for all components. CONCLUSIONS 4D-S-PACK could be a useful non-invasive clinical tool for assessing hemodynamics in brain AVMs. KEY POINTS • The 4D-MR angiography based on super-selective pseudo-continuous arterial spin labeling combined with CENTRA-keyhole and view-sharing (4D-S-PACK) enabled excellent vessel selectivity. • The 4D-S-PACK enabled the perfect identification of feeding arteries of brain arteriovenous malformation (AVM). • 4D-S-PACK could be a non-invasive clinical tool for assessing hemodynamics in brain AVMs.
Collapse
Affiliation(s)
- Osamu Togao
- Department of Clinical Radiology, Graduate School of Medical Sciences, Kyushu University, 3-1-1 Maidashi Higashi-ku, Fukuoka, 812-8582, Japan
| | - Makoto Obara
- Philips Japan, 13-37, Kohnan 2-chome, Minato-ku, Tokyo, 108-8507, Japan
| | | | - Koji Yamashita
- Department of Clinical Radiology, Graduate School of Medical Sciences, Kyushu University, 3-1-1 Maidashi Higashi-ku, Fukuoka, 812-8582, Japan
| | - Kazufumi Kikuchi
- Department of Clinical Radiology, Graduate School of Medical Sciences, Kyushu University, 3-1-1 Maidashi Higashi-ku, Fukuoka, 812-8582, Japan
| | - Daichi Momosaka
- Department of Clinical Radiology, Graduate School of Medical Sciences, Kyushu University, 3-1-1 Maidashi Higashi-ku, Fukuoka, 812-8582, Japan
| | - Yoshitomo Kikuchi
- Department of Clinical Radiology, Graduate School of Medical Sciences, Kyushu University, 3-1-1 Maidashi Higashi-ku, Fukuoka, 812-8582, Japan
| | - Ataru Nishimura
- Department of Neurosurgery, Graduate School of Medical Sciences, Kyushu University, 3-1-1 Maidashi Higashi-ku, Fukuoka, 812-8582, Japan
| | - Koichi Arimura
- Department of Neurosurgery, Graduate School of Medical Sciences, Kyushu University, 3-1-1 Maidashi Higashi-ku, Fukuoka, 812-8582, Japan
| | - Tatsuhiro Wada
- Division of Radiology, Department of Medical Technology, Kyushu University Hospital, Fukuoka, Japan
| | - Hiroo Murazaki
- Division of Radiology, Department of Medical Technology, Kyushu University Hospital, Fukuoka, Japan
| | - Koji Iihara
- Department of Neurosurgery, Graduate School of Medical Sciences, Kyushu University, 3-1-1 Maidashi Higashi-ku, Fukuoka, 812-8582, Japan
| | - Marc Van Cauteren
- Philips Japan, 13-37, Kohnan 2-chome, Minato-ku, Tokyo, 108-8507, Japan
| | - Akio Hiwatashi
- Department of Molecular Imaging & Diagnosis, Graduate School of Medical Sciences, Kyushu University, 3-1-1 Maidashi Higashi-ku, Fukuoka, 812-8582, Japan.
| |
Collapse
|
12
|
Ramachandran S, Mukherjee D, Delf J, Bown MJ, Kandiyil N. A comparison of arterial spin labelling with catheter angiography in evaluating arteriovenous malformations: a systematic review. Br J Radiol 2020; 93:20190830. [PMID: 32208976 PMCID: PMC10993222 DOI: 10.1259/bjr.20190830] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.4] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/30/2019] [Revised: 03/10/2020] [Accepted: 03/12/2020] [Indexed: 11/05/2022] Open
Abstract
OBJECTIVES To compare the performance of arterial spin labelling (ASL) in evaluating arteriovenous malformations (AVMs) against the current gold standard of catheter angiography. METHODS We systematically reviewed the published literature using EMBASE and Medline. We included studies that compared ASL to catheter angiography in the assessment of AVMs in three outcome domains: detection, angioarchitectural and haemodynamic features. RESULTS From 314 unique citations, 19 studies representing 289 patients with intracranial AVMs met our inclusion criteria. We did not pool data due to marked heterogeneity in study outcome measures. Seven studies showed high diagnostic performance of ASL in identifying arterial feeders, with sensitivity ranging from 84.6 to 100% and specificity ranging from 93.3 to 100%. Six studies showed strong ability in detecting arteriovenous shunting, with sensitivity ranging from 91.7 to 100% and specificity ranging from 90 to 100%. Seven studies demonstrated that ASL could identify nidal location and size as well as catheter angiography, while five studies showed relatively poorer performance in delineating venous drainage. Two studies showed 100% sensitivity of ASL in the identification of residual or obliterated AVMs following stereotactic radiosurgery. CONCLUSIONS Despite limitations in the current evidence base and technical challenges, this review suggests that ASL has a promising role in the work-up and post-treatment follow-up of AVMs. Larger scale prospective studies assessing the diagnostic performance of ASL are warranted. ADVANCES IN KNOWLEDGE ASL demonstrates overall validity in the evaluation of intracranial AVMs.
Collapse
Affiliation(s)
- Sanjeev Ramachandran
- University Hospitals of Leicester NHS Trust,
Leicester, United Kingdom
- University of Leicester,
Leicester, United Kingdom
| | - Deyashini Mukherjee
- University Hospitals of Leicester NHS Trust,
Leicester, United Kingdom
- University of Leicester,
Leicester, United Kingdom
| | - Jonathan Delf
- University Hospitals of Leicester NHS Trust,
Leicester, United Kingdom
| | - Matthew James Bown
- University Hospitals of Leicester NHS Trust,
Leicester, United Kingdom
- University of Leicester,
Leicester, United Kingdom
| | - Neghal Kandiyil
- University Hospitals of Leicester NHS Trust,
Leicester, United Kingdom
- University of Leicester,
Leicester, United Kingdom
| |
Collapse
|
13
|
Suzuki Y, Fujima N, van Osch MJP. Intracranial 3D and 4D MR Angiography Using Arterial Spin Labeling: Technical Considerations. Magn Reson Med Sci 2019; 19:294-309. [PMID: 31761840 PMCID: PMC7809141 DOI: 10.2463/mrms.rev.2019-0096] [Citation(s) in RCA: 21] [Impact Index Per Article: 3.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/30/2022] Open
Abstract
In the 1980’s some of the earliest studies of arterial spin labeling (ASL) MRI have demonstrated its ability to generate MR angiography (MRA) images. Thanks to many technical improvements, ASL has been successfully moving its position from the realm of research into the clinical area, albeit more known as perfusion imaging than as MRA. For MRA imaging, other techniques such as time-of-flight, phase contrast MRA and contrast-enhanced (CE) MRA are more popular choices for clinical applications. In the last decade, however, ASL-MRA has been experiencing a remarkable revival, especially because of its non-invasive nature, i.e. the fact that it does not rely on the use of contrast agent. Very importantly, there are additional benefits of using ASL for MRA. For example, its higher flexibility to achieve both high spatial and temporal resolution than CE dynamic MRA, and the capability of vessel specific visualization, in which the vascular tree arising from a selected artery can be exclusively visualized. In this article, the implementation and recent developments of ASL-based MRA are discussed; not only focusing on the basic sequences based upon pulsed ASL or pseudo-continuous ASL, but also including more recent labeling approaches, such as vessel-selective labeling, velocity-selective ASL, vessel-encoded ASL and time-encoded ASL. Although these ASL techniques have been already utilized in perfusion imaging and their usefulness has been suggested by many studies, some additional considerations should be made when employing them for MRA, since there is something more than the difference of the spatial resolution of the readout sequence. Moreover, extensive discussion is included on what readout sequence to use, especially by highlighting how to achieve high spatial resolution while keeping scan-time reasonable such that the ASL-MRA sequence can easily be included into a clinical examination.
Collapse
Affiliation(s)
- Yuriko Suzuki
- Institute of Biomedical Engineering, University of Oxford
| | - Noriyuki Fujima
- Department of Diagnostic and Interventional Radiology, Hokkaido University Hospital
| | | |
Collapse
|