1
|
Li H, Chen Z, Gao S, Hu J, Yang Z, Peng Y, Sun J. Performance Evaluation of Image Segmentation Using Dual-Energy Spectral CT Images with Deep Learning Image Reconstruction: A Phantom Study. Tomography 2025; 11:51. [PMID: 40423253 DOI: 10.3390/tomography11050051] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/09/2025] [Revised: 04/18/2025] [Accepted: 04/24/2025] [Indexed: 05/28/2025] Open
Abstract
Objectives: To evaluate the medical image segmentation performance of monochromatic images in various energy levels. Methods: The low-density module (25 mm in diameter, 6 Hounsfield Unit (HU) in density difference from background) from the ACR464 phantom was scanned at both 10 mGy and 5 mGy dose levels. Virtual monoenergetic images (VMIs) at different energy levels of 40, 50, 60, 68, 74, and 100 keV were generated. The images at 10 mGy reconstructed with 50% adaptive statistical iterative reconstruction veo (ASIR-V50%) were used to train an image segmentation model based on U-Net. The evaluation set used 5 mGy VMIs reconstructed with various reconstruction algorithms: FBP, ASIR-V50%, ASIR-V100%, deep learning image reconstruction (DLIR) with low (DLIR-L), medium (DLIR-M), and high (DLIR-H) strength levels. U-Net was employed as a tool to compare algorithm performance. Image noise and segmentation metrics, such as the DICE coefficient, intersection over union (IOU), sensitivity, and Hausdorff distance, were calculated to assess both image quality and segmentation performance. Results: DLIR-M and DLIR-H consistently achieved lower image noise and better segmentation performance, with the highest results observed at 60 keV, and DLIR-H had the lowest image noise across all energy levels. The performance metrics, including IOU, DICE, and sensitivity, were ranked in descending order with energy levels of 60 keV, 68 keV, 50 keV, 74 keV, 40 keV, and 100 keV. Specifically, at 60 keV, the average IOU values for each reconstruction method were 0.60 for FBP, 0.67 for ASIR-V50%, 0.68 for ASIR-V100%, 0.72 for DLIR-L, 0.75 for DLIR-M, and 0.75 for DLIR-H. The average DICE values were 0.75, 0.80, 0.82, 0.83, 0.85, and 0.86. The sensitivity values were 0.93, 0.91, 0.96, 0.95, 0.98, and 0.98. Conclusions: For low-density, non-enhancing objects under a low dose, the 60 keV VMIs performed better in automatic segmentation. DLIR-M and DLIR-H algorithms delivered the best results, whereas DLIR-H provided the lowest image noise and highest sensitivity.
Collapse
Affiliation(s)
- Haoyan Li
- Department of Radiology, Beijing Children's Hospital, Capital Medical University, National Center for Children's Health, No. 56, Nanlishi Road, Xicheng District, Beijing 100045, China
| | - Zhenpeng Chen
- Qingdao Academy of Chinese Medical Sciences, Shandong University of Traditional Chinese Medicine, Qingdao 266112, China
| | - Shuaiyi Gao
- Department of Radiology, Beijing Children's Hospital, Capital Medical University, National Center for Children's Health, No. 56, Nanlishi Road, Xicheng District, Beijing 100045, China
| | - Jiaqi Hu
- Department of Radiology, Beijing Children's Hospital, Capital Medical University, National Center for Children's Health, No. 56, Nanlishi Road, Xicheng District, Beijing 100045, China
| | - Zhihao Yang
- Department of Radiology, Beijing Children's Hospital, Capital Medical University, National Center for Children's Health, No. 56, Nanlishi Road, Xicheng District, Beijing 100045, China
| | - Yun Peng
- Department of Radiology, Beijing Children's Hospital, Capital Medical University, National Center for Children's Health, No. 56, Nanlishi Road, Xicheng District, Beijing 100045, China
| | - Jihang Sun
- Department of Radiology, Beijing Children's Hospital, Capital Medical University, National Center for Children's Health, No. 56, Nanlishi Road, Xicheng District, Beijing 100045, China
- Children's Hospital of Xinjiang Uygur Autonomous Region, Xinjiang Hospital of Beijing Children' s Hospital, Urumqi 830054, China
| |
Collapse
|
2
|
Siegel MJ, Thomas MA, Haq A, Seymore N, Sodhi KS, Abadia A. Comparison of Radiation Dose and Image Quality in Pediatric Abdominopelvic Photon-Counting Versus Energy-Integrating Detector CT. J Comput Assist Tomogr 2025:00004728-990000000-00425. [PMID: 39905977 DOI: 10.1097/rct.0000000000001730] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/22/2024] [Accepted: 12/24/2024] [Indexed: 02/06/2025]
Abstract
OBJECTIVE Adoption of abdominal photon counting detector CT (PCD-CT) into clinical pediatric CT practice requires evidence that it provides diagnostic images at acceptable radiation doses. Thus, this study aimed to compare radiation dose and image quality of PCD-CT and conventional energy-integrating detector CT (EID-CT) in pediatric abdominopelvic CT. MATERIALS AND METHODS This institutional review board-approved retrospective study included 147 children (median age 8.5 y; 80 boys, 67 girls) who underwent clinically indicated contrast-enhanced abdominopelvic PCD-CT between October 1, 2022 and April 30, 2023 and 147 children (median age 8.5 y; 74 boys, 73 girls) who underwent EID-CT between July 1, 2021 and January 1, 2022. Patients in the 2 groups were matched by age and effective diameter. Radiation dose parameters (CT dose index volume, CTDIvol; dose length product, DLP; size-specific dose estimate, SSDE) were recorded. In a subset of 25 matched pairs, subjective image quality was assessed on a scale of 1 to 4 (1=highest quality), and liver attenuation, dose-normalized noise, and contrast-to-noise ratio (CNR) were measured. Groups were compared using parametric and/or nonparametric testing. RESULTS Among the 147 matched pairs, there were no significant differences in sex (P=0.576), age (P=0.084), or diameter (P=0.668). PCD-CT showed significantly lower median CTDIvol, DLP, and SSDE (1.6 mGy, 63.8 mGy-cm, 3.1 mGy) compared with EID-CT (3.7 mGy, 155.3 mGy-cm, 6.0 mGy) (P<0.001). In the subset of 25 patients, PCD-CT and EID-CT showed no significant difference in overall image quality for reader 1 (1.0 vs. 1.0, P=0.781) or reader 2 (1.0 vs. 1.0, P=0.817), or artifacts for reader 1 (1.0 vs. 1.0, P=0.688) or reader 2 (1.0 vs. 1.0, P=0.219). After normalizing for radiation dose, image noise was significantly lower with PCD-CT (P<0.001), while CNR in the liver (P=0.244) and portal vein (P=0.079) were comparable to EID-CT. CONCLUSION Abdominopelvic PCD-CT in children significantly reduces radiation dose while maintaining subjective image quality, and accounting for dose levels, has the potential to lower image noise and achieve comparable CNR to EID-CT. These data expand understanding of the capabilities of PCD-CT and support its routine use in children.
Collapse
Affiliation(s)
- Marilyn J Siegel
- Mallinckrodt Institute of Radiology, Washington University School of Medicine, St Louis, MO
| | - Matthew Allan Thomas
- Mallinckrodt Institute of Radiology, Washington University School of Medicine, St Louis, MO
| | - Adeel Haq
- Mallinckrodt Institute of Radiology, Washington University School of Medicine, St Louis, MO
| | - Noah Seymore
- Mallinckrodt Institute of Radiology, Washington University School of Medicine, St Louis, MO
| | - Kushaljit Singh Sodhi
- Mallinckrodt Institute of Radiology, Washington University School of Medicine, St Louis, MO
| | | |
Collapse
|
3
|
Gallo-Bernal S, Peña-Trujillo V, Gee MS. Dual-energy computed tomography: pediatric considerations. Pediatr Radiol 2024; 54:2112-2126. [PMID: 39470784 DOI: 10.1007/s00247-024-06074-5] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 08/04/2024] [Revised: 10/07/2024] [Accepted: 10/08/2024] [Indexed: 11/01/2024]
Abstract
Multidetector computed tomography (CT) has revolutionized medicine and is now a fundamental aspect of modern radiology. Hardware and software advancements have significantly improved CT accessibility, image quality, and acquisition times. While considerable attention has been directed towards the potential risks of ionizing radiation from CT scans in children, recent concerns regarding the possible short- and long-term risks related to magnetic resonance imaging (MRI) conducted under general anesthesia have generated fresh interest in novel pediatric CT applications and techniques that allow imaging of awake patients at low radiation doses. Among these novel techniques, dual-energy CT (DECT) stands out for its ability to provide enhanced diagnostic information, reduce radiation doses further, and facilitate faster scans, making it a highly promising tool in pediatric radiology. This manuscript explores the current role of DECT in pediatric imaging, emphasizing its technical foundations, hardware configurations, and various reconstruction techniques. We discuss advanced post-processing techniques, such as material decomposition algorithms and virtual monoenergetic imaging, highlighting their clinical advantages in improving diagnostic accuracy and patient outcomes. Furthermore, the paper reviews the clinical applications of DECT in evaluating pulmonary perfusion, cardiovascular assessments, and oncologic imaging in pediatric patients.
Collapse
Affiliation(s)
- Sebastian Gallo-Bernal
- Department of Radiology, Massachusetts General Hospital, 55 Fruit St., Austen 250, Boston, MA, 02114, USA
- Harvard University, Cambridge, MA, USA
- Pediatric Imaging Research Center (PIRC), Massachusetts General Hospital, Boston, MA, USA
| | - Valeria Peña-Trujillo
- Department of Radiology, Massachusetts General Hospital, 55 Fruit St., Austen 250, Boston, MA, 02114, USA
- Harvard University, Cambridge, MA, USA
- Pediatric Imaging Research Center (PIRC), Massachusetts General Hospital, Boston, MA, USA
| | - Michael S Gee
- Department of Radiology, Massachusetts General Hospital, 55 Fruit St., Austen 250, Boston, MA, 02114, USA.
- Harvard University, Cambridge, MA, USA.
- Pediatric Imaging Research Center (PIRC), Massachusetts General Hospital, Boston, MA, USA.
| |
Collapse
|
4
|
Fletcher JG, Inoue A, Bratt A, Horst KK, Koo CW, Rajiah PS, Baffour FI, Ko JP, Remy-Jardin M, McCollough CH, Yu L. Photon-counting CT in Thoracic Imaging: Early Clinical Evidence and Incorporation Into Clinical Practice. Radiology 2024; 310:e231986. [PMID: 38501953 DOI: 10.1148/radiol.231986] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 03/20/2024]
Abstract
Photon-counting CT (PCCT) is an emerging advanced CT technology that differs from conventional CT in its ability to directly convert incident x-ray photon energies into electrical signals. The detector design also permits substantial improvements in spatial resolution and radiation dose efficiency and allows for concurrent high-pitch and high-temporal-resolution multienergy imaging. This review summarizes (a) key differences in PCCT image acquisition and image reconstruction compared with conventional CT; (b) early evidence for the clinical benefit of PCCT for high-spatial-resolution diagnostic tasks in thoracic imaging, such as assessment of airway and parenchymal diseases, as well as benefits of high-pitch and multienergy scanning; (c) anticipated radiation dose reduction, depending on the diagnostic task, and increased utility for routine low-dose thoracic CT imaging; (d) adaptations for thoracic imaging in children; (e) potential for further quantitation of thoracic diseases; and (f) limitations and trade-offs. Moreover, important points for conducting and interpreting clinical studies examining the benefit of PCCT relative to conventional CT and integration of PCCT systems into multivendor, multispecialty radiology practices are discussed.
Collapse
Affiliation(s)
- Joel G Fletcher
- From the Department of Radiology, Mayo Clinic, 200 1st St SW, Rochester, MN, 55905 (J.G.F., A.I., A.B., K.K.H., C.W.K., P.S.R., F.I.B., C.H.M., L.Y.); Department of Radiology, Shiga University of Medical Science, Shiga, Japan (A.I.); Department of Radiology, NYU Grossman School of Medicine, NYU Langone Health, New York, NY (J.P.K.); and IMALLIANCE-Haut-de-France, Valenciennes, France (M.R.J.)
| | - Akitoshi Inoue
- From the Department of Radiology, Mayo Clinic, 200 1st St SW, Rochester, MN, 55905 (J.G.F., A.I., A.B., K.K.H., C.W.K., P.S.R., F.I.B., C.H.M., L.Y.); Department of Radiology, Shiga University of Medical Science, Shiga, Japan (A.I.); Department of Radiology, NYU Grossman School of Medicine, NYU Langone Health, New York, NY (J.P.K.); and IMALLIANCE-Haut-de-France, Valenciennes, France (M.R.J.)
| | - Alex Bratt
- From the Department of Radiology, Mayo Clinic, 200 1st St SW, Rochester, MN, 55905 (J.G.F., A.I., A.B., K.K.H., C.W.K., P.S.R., F.I.B., C.H.M., L.Y.); Department of Radiology, Shiga University of Medical Science, Shiga, Japan (A.I.); Department of Radiology, NYU Grossman School of Medicine, NYU Langone Health, New York, NY (J.P.K.); and IMALLIANCE-Haut-de-France, Valenciennes, France (M.R.J.)
| | - Kelly K Horst
- From the Department of Radiology, Mayo Clinic, 200 1st St SW, Rochester, MN, 55905 (J.G.F., A.I., A.B., K.K.H., C.W.K., P.S.R., F.I.B., C.H.M., L.Y.); Department of Radiology, Shiga University of Medical Science, Shiga, Japan (A.I.); Department of Radiology, NYU Grossman School of Medicine, NYU Langone Health, New York, NY (J.P.K.); and IMALLIANCE-Haut-de-France, Valenciennes, France (M.R.J.)
| | - Chi Wan Koo
- From the Department of Radiology, Mayo Clinic, 200 1st St SW, Rochester, MN, 55905 (J.G.F., A.I., A.B., K.K.H., C.W.K., P.S.R., F.I.B., C.H.M., L.Y.); Department of Radiology, Shiga University of Medical Science, Shiga, Japan (A.I.); Department of Radiology, NYU Grossman School of Medicine, NYU Langone Health, New York, NY (J.P.K.); and IMALLIANCE-Haut-de-France, Valenciennes, France (M.R.J.)
| | - Prabhakar Shantha Rajiah
- From the Department of Radiology, Mayo Clinic, 200 1st St SW, Rochester, MN, 55905 (J.G.F., A.I., A.B., K.K.H., C.W.K., P.S.R., F.I.B., C.H.M., L.Y.); Department of Radiology, Shiga University of Medical Science, Shiga, Japan (A.I.); Department of Radiology, NYU Grossman School of Medicine, NYU Langone Health, New York, NY (J.P.K.); and IMALLIANCE-Haut-de-France, Valenciennes, France (M.R.J.)
| | - Francis I Baffour
- From the Department of Radiology, Mayo Clinic, 200 1st St SW, Rochester, MN, 55905 (J.G.F., A.I., A.B., K.K.H., C.W.K., P.S.R., F.I.B., C.H.M., L.Y.); Department of Radiology, Shiga University of Medical Science, Shiga, Japan (A.I.); Department of Radiology, NYU Grossman School of Medicine, NYU Langone Health, New York, NY (J.P.K.); and IMALLIANCE-Haut-de-France, Valenciennes, France (M.R.J.)
| | - Jane P Ko
- From the Department of Radiology, Mayo Clinic, 200 1st St SW, Rochester, MN, 55905 (J.G.F., A.I., A.B., K.K.H., C.W.K., P.S.R., F.I.B., C.H.M., L.Y.); Department of Radiology, Shiga University of Medical Science, Shiga, Japan (A.I.); Department of Radiology, NYU Grossman School of Medicine, NYU Langone Health, New York, NY (J.P.K.); and IMALLIANCE-Haut-de-France, Valenciennes, France (M.R.J.)
| | - Martine Remy-Jardin
- From the Department of Radiology, Mayo Clinic, 200 1st St SW, Rochester, MN, 55905 (J.G.F., A.I., A.B., K.K.H., C.W.K., P.S.R., F.I.B., C.H.M., L.Y.); Department of Radiology, Shiga University of Medical Science, Shiga, Japan (A.I.); Department of Radiology, NYU Grossman School of Medicine, NYU Langone Health, New York, NY (J.P.K.); and IMALLIANCE-Haut-de-France, Valenciennes, France (M.R.J.)
| | - Cynthia H McCollough
- From the Department of Radiology, Mayo Clinic, 200 1st St SW, Rochester, MN, 55905 (J.G.F., A.I., A.B., K.K.H., C.W.K., P.S.R., F.I.B., C.H.M., L.Y.); Department of Radiology, Shiga University of Medical Science, Shiga, Japan (A.I.); Department of Radiology, NYU Grossman School of Medicine, NYU Langone Health, New York, NY (J.P.K.); and IMALLIANCE-Haut-de-France, Valenciennes, France (M.R.J.)
| | - Lifeng Yu
- From the Department of Radiology, Mayo Clinic, 200 1st St SW, Rochester, MN, 55905 (J.G.F., A.I., A.B., K.K.H., C.W.K., P.S.R., F.I.B., C.H.M., L.Y.); Department of Radiology, Shiga University of Medical Science, Shiga, Japan (A.I.); Department of Radiology, NYU Grossman School of Medicine, NYU Langone Health, New York, NY (J.P.K.); and IMALLIANCE-Haut-de-France, Valenciennes, France (M.R.J.)
| |
Collapse
|
5
|
Kang Y, Hwang SH, Han K, Shin HJ. Comparison of image quality, contrast administration, and radiation doses in pediatric abdominal dual-layer detector dual-energy CT using propensity score matching analysis. Eur J Radiol 2023; 169:111177. [PMID: 37944333 DOI: 10.1016/j.ejrad.2023.111177] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/14/2023] [Revised: 10/25/2023] [Accepted: 10/27/2023] [Indexed: 11/12/2023]
Abstract
PURPOSE To compare the image quality, contrast administration, and radiation dose between single-energy CT (SECT) and dual-energy CT (DECT) in pediatric patients. METHODS From March to December 2021, children who underwent abdominal SECT or DECT were retrospectively included in this study. The DECT group received 10-30 % less contrast than the routine dose. CT images were obtained at hepatic venous phase using a routine reconstruction method (iDose4). DECT scans were additionally reconstructed with a virtual monoenergetic image (VMI) at 40 and 65 keV. Quantitative image evaluations compared the contrast-to-noise ratio (CNR) and signal-to-noise ratio (SNR) of the liver, portal vein, and pancreas. Qualitative analysis assessed degree of contrast enhancement, lesion or organ conspicuity, image noise, artificiality, and overall image quality. RESULTS Among 318 patients, 112 (median age, 16 years; 56 in each group) were included after propensity score matching. Compared with the SECT group, DECT group with iDose4 demonstrated lower CNRs and SNRs, while VMI at 40 or 65 keV showed no significant difference. In qualitative analysis, iDose4 produced higher scores on artificiality, and VMI at 40 keV demonstrated superior contrast enhancement and lesion conspicuity in the DECT group. Overall image quality was higher with VMI 65 keV among the DECT patients, and there was no significant difference compared to SECT. The volume CT dose index (CTDIvol) did not differ significantly between the two groups (median, 2.8 mGy vs. 2.9 mGy; p = 0.802). The injected contrast volume was reduced by 10 % in the DECT group. CONCLUSION Pediatric abdominal DECT with reduced contrast administration showed no significant differences in image quality and radiation dose compared to SECT.
Collapse
Affiliation(s)
- Yeseul Kang
- Department of Radiology, Research Institute of Radiological Science and Center for Clinical Imaging Data Science, Yonsei University College of Medicine, Yongin Severance Hospital 363, Dongbaekjukjeon-daero, Giheung-gu, Yongin-si, Gyeonggi-do 16995, Republic of Korea
| | - Shin Hye Hwang
- Department of Radiology, Research Institute of Radiological Science and Center for Clinical Imaging Data Science, Yonsei University College of Medicine, Yongin Severance Hospital 363, Dongbaekjukjeon-daero, Giheung-gu, Yongin-si, Gyeonggi-do 16995, Republic of Korea
| | - Kyunghwa Han
- Department of Radiology, Research Institute of Radiological Science and Center for Clinical Imaging Data Science, Severance Hospital, 50-1, Yonsei-ro, Seodaemun-gu, Seoul 03722, Republic of Korea
| | - Hyun Joo Shin
- Department of Radiology, Research Institute of Radiological Science and Center for Clinical Imaging Data Science, Yonsei University College of Medicine, Yongin Severance Hospital 363, Dongbaekjukjeon-daero, Giheung-gu, Yongin-si, Gyeonggi-do 16995, Republic of Korea.
| |
Collapse
|
6
|
Peña-Trujillo V, Gallo-Bernal S, Tung EL, Gee MS. Pediatric Applications of Dual-Energy Computed Tomography. Radiol Clin North Am 2023; 61:1069-1083. [PMID: 37758357 DOI: 10.1016/j.rcl.2023.05.006] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/03/2023]
Abstract
There is renewed interest in novel pediatric dual-energy computed tomography (DECT) applications that can image awake patients faster and at low radiation doses. DECT enables the simultaneous acquisition of 2 data sets at different energy levels, allowing for better material characterization and unique image reconstructions that enhance image analysis and provide quantitative and qualitative information about tissue composition. Pediatric DECT reduces radiation doses further while accelerating image acquisition and improving motion robustness. Current applications include the improved evaluation of congenital and acquired cardiovascular anomalies, lung perfusion and ventilation, renal stone composition, tumor extension and treatment response, and gastrointestinal diseases.
Collapse
Affiliation(s)
- Valeria Peña-Trujillo
- Division of Pediatric Imaging, Massachusetts General Hospital, 55 Fruit Street, Boston, MA 02114, USA; Department of Radiology, Massachusetts General Hospital, 55 Fruit Street, Boston, MA 02114, USA; Department of Radiology, Harvard Medical School, Boston, MA, USA. https://twitter.com/valeria_pt22
| | - Sebastian Gallo-Bernal
- Division of Pediatric Imaging, Massachusetts General Hospital, 55 Fruit Street, Boston, MA 02114, USA; Department of Radiology, Massachusetts General Hospital, 55 Fruit Street, Boston, MA 02114, USA; Department of Radiology, Harvard Medical School, Boston, MA, USA. https://twitter.com/SebGal1230
| | - Erik L Tung
- Department of Radiology, Massachusetts General Hospital, 55 Fruit Street, Boston, MA 02114, USA; Department of Radiology, Harvard Medical School, Boston, MA, USA. https://twitter.com/ErikTungMD
| | - Michael S Gee
- Division of Pediatric Imaging, Massachusetts General Hospital, 55 Fruit Street, Boston, MA 02114, USA; Department of Radiology, Massachusetts General Hospital, 55 Fruit Street, Boston, MA 02114, USA; Department of Radiology, Harvard Medical School, Boston, MA, USA.
| |
Collapse
|
7
|
Adam SZ, Rabinowich A, Kessner R, Blachar A. Spectral CT of the abdomen: Where are we now? Insights Imaging 2021; 12:138. [PMID: 34580788 PMCID: PMC8476679 DOI: 10.1186/s13244-021-01082-7] [Citation(s) in RCA: 43] [Impact Index Per Article: 10.8] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/30/2021] [Accepted: 08/16/2021] [Indexed: 12/14/2022] Open
Abstract
Spectral CT adds a new dimension to radiological evaluation, beyond assessment of anatomical abnormalities. Spectral data allows for detection of specific materials, improves image quality while at the same time reducing radiation doses and contrast media doses, and decreases the need for follow up evaluation of indeterminate lesions. We review the different acquisition techniques of spectral images, mainly dual-source, rapid kV switching and dual-layer detector, and discuss the main spectral results available. We also discuss the use of spectral imaging in abdominal pathologies, emphasizing the strengths and pitfalls of the technique and its main applications in general and in specific organs.
Collapse
Affiliation(s)
- Sharon Z Adam
- Department of Diagnostic Radiology, Tel Aviv Sourasky Medical Center, 6 Weizmann St., 6423906, Tel Aviv, Israel. .,Sackler School of Medicine, Tel Aviv University, Tel Aviv, Israel.
| | - Aviad Rabinowich
- Department of Diagnostic Radiology, Tel Aviv Sourasky Medical Center, 6 Weizmann St., 6423906, Tel Aviv, Israel.,Sackler School of Medicine, Tel Aviv University, Tel Aviv, Israel
| | - Rivka Kessner
- Department of Diagnostic Radiology, Tel Aviv Sourasky Medical Center, 6 Weizmann St., 6423906, Tel Aviv, Israel.,Sackler School of Medicine, Tel Aviv University, Tel Aviv, Israel
| | - Arye Blachar
- Department of Diagnostic Radiology, Tel Aviv Sourasky Medical Center, 6 Weizmann St., 6423906, Tel Aviv, Israel.,Sackler School of Medicine, Tel Aviv University, Tel Aviv, Israel
| |
Collapse
|