1
|
Mathiessen A, Onuoha I, Luh R, Driban JB, Roberts MB, Eaton CB, McAlindon TE, Duryea J. Radiographic joint space width in individuals with hand osteoarthritis: Are their "healthy" joints really healthy? Osteoarthritis Cartilage 2025; 33:638-646. [PMID: 37865135 DOI: 10.1016/j.joca.2023.10.004] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 11/06/2022] [Revised: 10/08/2023] [Accepted: 10/09/2023] [Indexed: 10/23/2023]
Abstract
OBJECTIVES We aimed to investigate the systemic nature of hand osteoarthritis (OA). We hypothesized that people who suffer from hand OA would display narrower radiographic joint space width (JSW) - not only in joints with apparent radiographic OA but also in their unaffected "healthy" joints. METHOD We examined 3394 participants from the Osteoarthritis Initiative with available dominant hand radiographs at baseline. Cases were defined as having interphalangeal OA (IPOA) based on a Kellgren and Lawrence (KL) score of ≥2 in two or more finger joints, whereas controls did not have IPOA. We used custom software to make JSW measurements of the metacarpophalangeal, proximal interphalangeal, and distal interphalangeal joints in fingers 2-5 per hand. In joint-level analyses, we included only KL score=0, allowing us to compare all joints without IPOA in cases and controls. We used generalized estimating equation models to compare JSW between both groups, adjusted for age, gender, metacarpal length, and joint type. RESULTS Finger joints without radiographic OA had significantly narrower JSW in the IPOA group compared to finger joints in the control group (p < 0.001). The differences were significant across all joint types and for both total JSW measurements as well as for central and lateral sub-regions within each joint group (p < 0.001). CONCLUSION Unaffected finger joints in people with IPOA had narrower joint space than joints of healthy controls. This implies a systemic nature of hand OA, in which people may have a predisposition for general cartilage deterioration.
Collapse
Affiliation(s)
- Alexander Mathiessen
- Brigham and Women's Hospital, Boston, MA, USA; Center for Treatment of Rheumatic and Musculoskeletal Diseases (REMEDY), Diakonhjemmet Hospital, Oslo, Norway; Institute of Clinical Medicine, University of Oslo, Oslo, Norway.
| | | | - Rebecca Luh
- Brigham and Women's Hospital, Boston, MA, USA
| | | | - Mary B Roberts
- Center for Primary Care and Prevention, Kent Hospital, Warwick, RI, USA
| | - Charles B Eaton
- Department of Family Medicine Warren Alpert Medical School of Brown University, Providence, RI, USA; Department of Epidemiology, School of Public Health of Brown University, Providence, RI, USA
| | | | | |
Collapse
|
2
|
Hunziker EB, Nishii N, Shintani N, Lippuner K, Keel MJB, Voegelin E. The chondrogenic potential of the bovine tendon sheath-a novel source of stem cells for cartilage repair. Stem Cells 2025; 43:sxae071. [PMID: 39656905 DOI: 10.1093/stmcls/sxae071] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/17/2024] [Accepted: 10/17/2024] [Indexed: 12/17/2024]
Abstract
The human hand is traumatized more frequently than any other bodily part. Trauma and pathological processes (eg, rheumatoid arthritis, osteoarthritis) commonly implicate the finger joints and specifically damage also the layer of articular cartilage. Endeavors are now being made to surgically repair such cartilage lesions biologically using tissue-engineering approaches that draw on donor cells and/or donor tissues. The tendon sheaths, particularly their inner layers, that is, the peritendineum, surround the numerous tendons in the hand. The peritendineum is composed of mesenchymal tissue. We hypothesize that this tissue harbors pluripotent mesenchymal stem cells and thus could be used for cartilage repair, irrespective of the donor's age. Using a bovine model (young calves vs adult cows), the pluripotentiality of the peritendineal stem cells, namely, their osteogenicity, chondrogenicity, and adipogenicity, was investigated by implementing conventional techniques. Subsequently, the chondrogenic potential of the peritendineal tissue itself was analyzed. Its differentiation into cartilage was induced by the application of specific growth factors (members of the TGF-β-superfamily). The characteristics of the tissue formed were evaluated structurally (immuno) histochemically, histomorphometrically, and biochemically (gene expression and protein level). Our data confirm that the bovine peritendineum contains stem cells whose pluripotentiality is independent of donor age. This tissue could also be induced to differentiate into cartilage, likewise, irrespective of the donor's age. Preliminary investigations with adult human peritendineal biopsy material derived from the hand's peritendineal flexor tendon sheaths revealed that this tissue can also be induced to differentiate into cartilage.
Collapse
Affiliation(s)
- Ernst B Hunziker
- Department of Osteoporosis, Inselspital Bern University Hospital, 3010 Bern, Switzerland
- Department of Orthopedic Surgery, Inselspital Bern University Hospital, 3010 Bern, Switzerland
| | - Naomi Nishii
- Department of Osteoporosis, Inselspital Bern University Hospital, 3010 Bern, Switzerland
- Department of Orthopedic Surgery, Inselspital Bern University Hospital, 3010 Bern, Switzerland
| | - Nahoko Shintani
- Department of Osteoporosis, Inselspital Bern University Hospital, 3010 Bern, Switzerland
- Department of Orthopedic Surgery, Inselspital Bern University Hospital, 3010 Bern, Switzerland
| | - Kurt Lippuner
- Department of Osteoporosis, Inselspital Bern University Hospital, 3010 Bern, Switzerland
| | - Marius J B Keel
- Trauma Center Hirslanden, Clinic Hirslanden, Zurich, Medical School, University of Zurich, 8006 Zurich, Switzerland
| | - Esther Voegelin
- Department of Plastic and Hand Surgery, Inselspital Bern University Hospital, 3010 Bern, Switzerland
| |
Collapse
|
3
|
Tse JJ, Contreras D, Salat P, Barber CEH, Hazlewood GS, Barnabe C, Penney C, Ibrahem A, Mosher D, Manske SL. Evaluating high-resolution computed tomography derived 3-D joint space metrics of the metacarpophalangeal joints between rheumatoid arthritis and age- and sex-matched control participants. Front Med (Lausanne) 2024; 11:1387532. [PMID: 38784224 PMCID: PMC11112086 DOI: 10.3389/fmed.2024.1387532] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/17/2024] [Accepted: 04/16/2024] [Indexed: 05/25/2024] Open
Abstract
Introduction Rheumatoid arthritis (RA) is commonly characterized by joint space narrowing. High-resolution peripheral quantitative computed tomography (HR-pQCT) provides unparalleled in vivo visualization and quantification of joint space in extremity joints commonly affected by RA, such as the 2nd and 3rd metacarpophalangeal joints. However, age, sex, and obesity can also influence joint space narrowing. Thus, this study aimed to determine whether HR-pQCT joint space metrics could distinguish between RA patients and controls, and determine the effects of age, sex and body mass index (BMI) on these joint space metrics. Methods HR-pQCT joint space metrics (volume, width, standard deviation of width, maximum/minimum width, and asymmetry) were acquired from RA patients and age-and sex-matched healthy control participants 2nd and 3rd MCP joints. Joint health and functionality were assessed with ultrasound (i.e., effusion and inflammation), hand function tests, and questionnaires. Results HR-pQCT-derived 3D joint space metrics were not significantly different between RA and control groups (p > 0.05), despite significant differences in inflammation and joint function (p < 0.05). Joint space volume, mean joint space width (JSW), maximum JSW, minimum JSW were larger in males than females (p < 0.05), while maximum JSW decreased with age. No significant association between joint space metrics and BMI were found. Conclusion HR-pQCT did not detect group level differences between RA and age-and sex-matched controls. Further research is necessary to determine whether this is due to a true lack of group level differences due to well-controlled RA, or the inability of HR-pQCT to detect a difference.
Collapse
Affiliation(s)
- Justin J. Tse
- McCaig Institute for Bone and Joint Health, Cumming School of Medicine, University of Calgary, Calgary, AB, Canada
- Department of Radiology, Cumming School of Medicine, University of Calgary, Calgary, AB, Canada
| | - Dani Contreras
- McCaig Institute for Bone and Joint Health, Cumming School of Medicine, University of Calgary, Calgary, AB, Canada
- Department of Community Health Sciences, Cumming School of Medicine, University of Calgary, Calgary, AB, Canada
| | - Peter Salat
- Department of Radiology, Cumming School of Medicine, University of Calgary, Calgary, AB, Canada
| | - Claire E. H. Barber
- McCaig Institute for Bone and Joint Health, Cumming School of Medicine, University of Calgary, Calgary, AB, Canada
- Division of Rheumatology, Cumming School of Medicine, University of Calgary, Calgary, AB, Canada
| | - Glen S. Hazlewood
- McCaig Institute for Bone and Joint Health, Cumming School of Medicine, University of Calgary, Calgary, AB, Canada
- Division of Rheumatology, Cumming School of Medicine, University of Calgary, Calgary, AB, Canada
| | - Cheryl Barnabe
- Division of Rheumatology, Cumming School of Medicine, University of Calgary, Calgary, AB, Canada
| | - Chris Penney
- Division of Rheumatology, Cumming School of Medicine, University of Calgary, Calgary, AB, Canada
| | - Ahmed Ibrahem
- Division of Rheumatology, Cumming School of Medicine, University of Calgary, Calgary, AB, Canada
| | - Dianne Mosher
- Division of Rheumatology, Cumming School of Medicine, University of Calgary, Calgary, AB, Canada
| | - Sarah L. Manske
- McCaig Institute for Bone and Joint Health, Cumming School of Medicine, University of Calgary, Calgary, AB, Canada
- Department of Radiology, Cumming School of Medicine, University of Calgary, Calgary, AB, Canada
| |
Collapse
|
4
|
Chughtai M, Scollan JP, Emara AK, Brej B, Steckler A, Churchill JL, Ferre A, Saluan P, Styron JF. The "Fight Bite" Saline Joint Loading Test: Effectiveness in Detecting Simulated Traumatic Metacarpophalangeal Arthrotomies. Hand (N Y) 2023; 18:792-797. [PMID: 34991409 PMCID: PMC10336812 DOI: 10.1177/15589447211068184] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 11/15/2022]
Abstract
Background: The saline load test is routinely used to recognize other joints' traumatic arthrotomies; however, there are currently no studies evaluating the novelty of this test for metacarpophalangeal joints (MCPJs). This study aimed to investigate the effectiveness and sensitivity of saline load testing in identifying the traumatic arthrotomies of the MCPJs using human cadavers. Methods: This was a cadaveric study of 16 hands (79 MCPJs). Traumatic arthrotomies were created using 11-blade stab-incisions, followed by blunt probing into the joint on the radial or ulnar side of the flexed MCPJs. A 3-mL syringe was used to inject intra-articular methylene-blue-dyed saline from the contralateral side. The volume at saline extravasation was recorded. Test sensitivity and factors influencing extravasation volume were assessed. Results: The mean (range) volume injected to identify arthrotomy of all MCPJs was 0.18 mL (0.1-0.4 mL). The mean volume to identify MCPJ arthrotomy of the thumb, index, long, ring, and small fingers was 0.16 mL (0.1-0.3 mL), 0.19 mL (0.1-0.3 mL), 0.21 mL (0.1-0.4 mL), 0.17 mL (0.1-0.3 mL), and 0.16 mL (0.1-0.3 mL), respectively. Cadaver age, laterality, and joint range of motion were not significantly associated with the injected volume at extravasation(P > .05, each). Injection volumes of 0.3 and 0.32 mL were required to detect arthrotomies at 95% and 99% sensitivities across all MCPJs. None of the MCPJs required > 0.4 mL to detect arthrotomy. Conclusions: Saline joint loading volumes to detect traumatic arthrotomy were similar for all MCPJs. Injection volumes of 0.32 mL is suggested for 99% sensitivity. Our findings provide the first report, to our knowledge, on intra-articular injection volumes expected to detect an arthrotomy of MCPJ. This is critical for further validation using in vivo clinical studies.
Collapse
Affiliation(s)
| | | | | | - Ben Brej
- Cleveland Clinic Foundation, OH, USA
| | | | | | | | | | | |
Collapse
|
5
|
The relationship between structural analysis of the hand and clinical characteristics in psoriatic arthritis. Sci Rep 2022; 12:18913. [PMID: 36344592 PMCID: PMC9640661 DOI: 10.1038/s41598-022-23555-5] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/05/2022] [Accepted: 11/02/2022] [Indexed: 11/09/2022] Open
Abstract
Up to now, there is only limited information available on a possible relationship between clinical characteristics and the mineralization of metacarpal bones and finger joint space distance (JSD) in patients with psoriatic arthritis (PsA). Computerized digital imaging techniques like digital X-ray radiogrammetry (DXR) and computer-aided joint space analysis (CAJSA) have significantly improved the structural analysis of hand radiographs and facilitate the recognition of radiographic damage. The objective of this study was to evaluate clinical features which potentially influence periarticular mineralization of the metacarpal bones and finger JSD in PsA-patients. 201 patients with PsA underwent computerized measurements of the metacarpal bone mineral density (BMD) with DXR and JSD of all finger joints by CAJSA. DXR-BMD and JSD were compared with clinical features such as age and sex, disease duration, C-reactive protein (CRP) as well as treatment with prednisone and disease-modifying antirheumatic drugs (DMARDs). A longer disease duration and an elevated CRP value were associated with a significant reduction of DXR-BMD, whereas JSD-parameters were not affected by both parameters. DXR-BMD was significantly reduced in the prednisone group (-0.0383 g/cm²), but prednisone showed no impact on finger JSD. Patients under the treatment with bDMARDs presented significant lower DXR-BMD (-0.380 g/cm²), JSDMCP (-0.0179 cm), and JSDPIP (-0.0121 cm) values. Metacarpal BMD was influenced by inflammatory activity, prednisone use, and DMARDs. In contrast, finger JSD showed only a change compared to baseline therapy. Therefore, metacarpal BMD as well as finger JSD represent radiographic destruction under different aspects.
Collapse
|
6
|
Minh NN, Nguyen NPT, Ngoc CN, Duy TT, Huy TN, Do BN, Viet TT. Application of ImageJ software for quantification of Hand Joint Space Narrowing in Patients with Rheumatoid Arthritis. Curr Rheumatol Rev 2021; 18:136-143. [PMID: 34080966 DOI: 10.2174/1573397117666210602113848] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/06/2020] [Revised: 02/01/2021] [Accepted: 03/16/2021] [Indexed: 11/22/2022]
Abstract
BACKGROUND ImageJ software is used to quantify the joint space width (JSW) of hand and wrist in patients with rheumatoid arthritis (RA) as well as in the healthy control group. METHOD Forty-one RA patients and 31 healthy controls are included in this study. All of 72 participants underwent digital radiography of the bilateral hand and wrist, then all the images were opened by ImageJ software to measure the width of wrist and hand joint space (total 2160 joints). Joint space narrowing (JSN) was defined if the width was less than the mean - 2SD of the control group. RESULT The mean JSW of all sites of wrist and hand joints of RA patients was significantly reduced as compared to those in the control group (p<0.001). There were 37/41 (90.24%) RA patients who had JSN in at least one joint in hand or wrist. In total, 70.89% of joints on the right and 68.46% of joints on the left wrist and hand had JSN. CONCLUSION ImageJ software was simple and convenient , which helps rheumatologists quantify the width of joint space for diagnosis and follow-up in RA patients.
Collapse
Affiliation(s)
- Nui Nguyen Minh
- Department of Rheumatology, Military Hospital 103, Hanoi, Vietnam
| | | | - Chau Nguyen Ngoc
- Department of Rheumatology, Military Hospital 103, Hanoi, Vietnam
| | - Tien Tran Duy
- Department of Rheumatology, Military Hospital 103, Hanoi, Vietnam
| | - Thong Nguyen Huy
- Department of Rheumatology, Military Hospital 103, Hanoi, Vietnam
| | - Binh Nhu Do
- Division of Military Science, Military Hospital 103, Hanoi, Vietnam
| | | |
Collapse
|
7
|
Pfeil A, Oelzner P, Hoffmann T, Renz DM, Wolf G, Böttcher J. Sind röntgenologische Scoring-Methoden als Parameter zur
Verlaufsbeurteilung der rheumatoiden Arthritis noch
zeitgemäß? AKTUEL RHEUMATOL 2021. [DOI: 10.1055/a-1394-0299] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/21/2022]
Abstract
ZusammenfassungDie radiologische Progression beschreibt das Ausmaß der
Gelenkzerstörung im Verlauf einer rheumatoiden Arthritis. Zur
Quantifizierung der radiologischen Progression werden Scoring-Methoden
(z. B. van der Heijde Modifikation des Sharp-Score) eingesetzt. In
verschiedenen Studien zu biologischen- bzw. target-synthetischen Disease
Modifying Anti-Rheumatic Drugs gelang nur unzureichend eine Differenzierung
der radiologischen Progression. Zudem finden die Scores oft keinen
routinemäßigen Einsatz in der klinischen
Entscheidungsfindung. Durch die computerbasierte Analyse von
Handröntgenaufnahmen ist eine valide Quantifizierung der
radiologischen Progression und die zuverlässige Bewertung von
Therapieeffekten möglich. Somit stellen die computerbasierten
Methoden eine vielversprechende Alternative in der Quantifizierung der
radiologischen Progression dar.
Collapse
Affiliation(s)
- Alexander Pfeil
- Klinik für Innere Medizin III, Universitätsklinikum
Jena, Jena, Deutschland
| | - Peter Oelzner
- Klinik für Innere Medizin III, Universitätsklinikum
Jena, Jena, Deutschland
| | - Tobias Hoffmann
- Klinik für Innere Medizin III, Universitätsklinikum
Jena, Jena, Deutschland
| | - Diane M. Renz
- Institut für Diagnostische und Interventionelle Radiologie,
Medizinische Hochschule Hannover, Hannover, Deutschland
| | - Gunter Wolf
- Klinik für Innere Medizin III, Universitätsklinikum
Jena, Jena, Deutschland
| | - Joachim Böttcher
- Medizinische Fakultät, Friedrich-Schiller-Universität
Jena, Jena, Deutschland
| |
Collapse
|
8
|
Quantification of Joint Space Width Difference on Radiography Via Phase-Only Correlation (POC) Analysis: a Phantom Study Comparing with Various Tomographical Modalities Using Conventional Margin-Contouring. J Digit Imaging 2020; 34:96-104. [PMID: 33269449 DOI: 10.1007/s10278-020-00406-1] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/25/2020] [Revised: 11/04/2020] [Accepted: 11/19/2020] [Indexed: 10/22/2022] Open
Abstract
Several visual scoring methods are currently used to assess progression of rheumatoid arthritis (RA) on radiography. However, they are limited by its subjectivity and insufficient sensitivity. We have developed an original measurement system which uses a technique called phase-only correlation (POC). The purpose of this study is to validate the system by using a phantom simulating the joint of RA patients.A micrometer measurement apparatus that can adjust arbitrary joint space width (JSW) in a phantom joint was developed to define true JSW. The phantom was scanned with radiography, 320 multi detector CT (MDCT), high-resolution peripheral quantitative CT (HR-pQCT), cone beam CT (CBCT), and tomosynthesis. The width was adjusted to the average size of a women's metacarpophalangeal joint, from 1.2 to 2.2 mm with increments of 0.1 mm and 0.01 mm. Radiographical images were analyzed by the POC-based system and manual method, and images from various tomographical modalities were measured via the automatic margin detection method. Correlation coefficients between true JSW difference and measured JSW difference were all strong at 0.1 mm intervals with radiography (POC-based system and manual method), CBCT, 320MDCT, HR-pQCT, and tomosynthesis. At 0.01 mm intervals, radiography (POC-based system), 320MDCT, and HR-pQCT had strong correlations, while radiography (manual method) and CBCT had low correlations, and tomosynthesis had no statistically significant correlation. The smallest detectable changes for radiography (POC-based system), radiography (manual method), 320MDCT, HR-pQCT, CBCT, and tomosynthesis were 0.020 mm, 0.041 mm, 0.076 mm, 0.077 mm, 0.057 mm, and 0.087 mm, respectively. We conclude that radiography analyzed with the POC-based system might sensitively detect minute joint space changes of the finger joint.
Collapse
|
9
|
Haghnegahdar A, Pakshir H, Ghanbari I. Correlation between Skeletal Age and Metacarpal Bones and Metacarpophalangeal Joints Dimensions. JOURNAL OF DENTISTRY (SHIRAZ, IRAN) 2019; 20:159-164. [PMID: 31579689 PMCID: PMC6732183 DOI: 10.30476/dentjods.2019.44904] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Indexed: 11/23/2022]
Abstract
Statement of the Problem: Currently, two major methods have been introduced for bone age assessment using left hand radiography. The first approach is Greulich and Pyle, which is very subjective. The second method is Tanner and Whitehouse, which is very time consuming and its morphological criteria are not quantitative, therefore it is hardly used.
Purpose: The purpose of this study is to evaluate the relationship between skeletal age and bone size and joint space measurements among Asian children using hand radiographs and using this correlation as an aid in determining bone age.
Materials and Method: In this analytic research, 304 hand radiographs from Asian children with normal development have been included in this study (155 female, 149 male). Two radiologists using Greulich and Pyle method assessed their bone ages. The 2nd-5th metacarpal bones length and width and 2nd-5th metacarpophalangeal joints width and length were manually measured by Adobe Photoshop and compared with subjects’ skeletal age. Pearson correlation was used to determine the relationship.
Results: Pearson correlation between bone age and metacarpal bones length was 0.902-0.938; metacarpal bones width was 0.452-0.850; metacarpophalangeal joints width was 0.656 - 0.811, and metacarpophalangeal joints length was 0.920 - 0.947.
Conclusion: Regarding Pearson correlation, metacarpophalangeal joints length, metacarpal bones length, metacarpophalangeal joints width, and metacarpal bones width showed significant relationship with bone age, respectively. These measurements can be used as accessory criteria for bone age assessment using left hand radiography, to reduce inter-observer reading differences.
Collapse
Affiliation(s)
- Abdolaziz Haghnegahdar
- Dept. of Maxillofacial Radiology, School of Dentistry, Shiraz University of Medical Sciences, Shiraz, Iran
| | - Hamidreza Pakshir
- Dept. of Maxillofacial Orthodontics School of Dentistry, Shiraz University of Medical Sciences, Shiraz, Iran
| | - Ilnaz Ghanbari
- Postgraduate Student Dept. of Oral and Maxillofacial Surgery, School of Dentistry, Shiraz University of Medical Sciences, Shiraz, Iran
| |
Collapse
|
10
|
Kato K, Yasojima N, Tamura K, Ichikawa S, Sutherland K, Kato M, Fukae J, Tanimura K, Tanaka Y, Okino T, Lu Y, Kamishima T. Detection of Fine Radiographic Progression in Finger Joint Space Narrowing Beyond Human Eyes: Phantom Experiment and Clinical Study with Rheumatoid Arthritis Patients. Sci Rep 2019; 9:8526. [PMID: 31189913 PMCID: PMC6561904 DOI: 10.1038/s41598-019-44747-6] [Citation(s) in RCA: 6] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/05/2018] [Accepted: 05/24/2019] [Indexed: 12/12/2022] Open
Abstract
The visual assessment of joint space narrowing (JSN) on radiographs of rheumatoid arthritis (RA) patients such as the Genant-modified Sharp score (GSS) is widely accepted but limited by its subjectivity and insufficient sensitivity. We developed a software application which can assess JSN quantitatively using a temporal subtraction technique for radiographs, in which the chronological change in JSN between two radiographs was defined as the joint space difference index (JSDI). The aim of this study is to prove the superiority of the software in terms of detecting fine radiographic progression in finger JSN over human observers. A micrometer measurement apparatus that can adjust arbitrary joint space width (JSW) in a phantom joint was developed to define true JSW. We compared the smallest detectable changes in JSW between the JSDI and visual assessment using phantom images. In a clinical study, 222 finger joints without interval score change on GSS in 15 RA patients were examined. We compared the JSDI between joints with and without synovial vascularity (SV) on power Doppler ultrasonography during the follow-up period. True JSW difference was correlated with JSDI for JSW differences ranging from 0.10 to 1.00 mm at increments of 0.10 mm (R2 = 0.986 and P < 0.001). Rheumatologists were difficult to detect JSW difference of 0.30 mm or less. The JSDI of finger joints with SV was significantly higher than those without SV (P = 0.030). The software can detect fine differences in JSW that are visually unrecognizable.
Collapse
Affiliation(s)
- Kazuki Kato
- Graduate School of Health Sciences, Hokkaido University, North 12 West 5, Kita-ku, Sapporo, 060-0812, Japan
| | - Nobutoshi Yasojima
- Department of Radiology, NTT Sapporo Medical Center, South 1 West 15, Chuo-ku, Sapporo, 060-0061, Japan
| | - Kenichi Tamura
- Department of Mechanical Engineering, College of Engineering, Nihon University, Tokusada Aza Nakagawara 1, Tamura-cho, Koriyama, 963-8642, Japan
| | - Shota Ichikawa
- Department of Radiological Technology, Kurashiki Central Hospital, Miwa 1, Kurashiki, 710-8602, Japan
| | - Kenneth Sutherland
- Division of Photonic Bioimaging, Faculty of Medicine Research Center for Cooperative Projects, Hokkaido University, North 15 West 7, Kita-ku, Sapporo, 060-8638, Japan
| | - Masaru Kato
- Department of Rheumatology, Endocrinology and Nephrology, Faculty of Medicine and Graduate School of Medicine, Hokkaido University, North 15 West 7, Kita-ku, Sapporo, 060-8638, Japan
| | - Jun Fukae
- Department of Rheumatology, Hokkaido Medical Center for Rheumatic Diseases, Kotoni 1-3, Nishi-ku, Sapporo, 063-0811, Japan
| | - Kazuhide Tanimura
- Department of Rheumatology, Hokkaido Medical Center for Rheumatic Diseases, Kotoni 1-3, Nishi-ku, Sapporo, 063-0811, Japan
| | - Yuki Tanaka
- Graduate School of Health Sciences, Hokkaido University, North 12 West 5, Kita-ku, Sapporo, 060-0812, Japan
| | - Taichi Okino
- Department of Radiological Technology, Sapporo City General Hospital, North 11 West 13, Chuo-ku, Sapporo, 060-8604, Japan
| | - Yutong Lu
- Faculty of Health Sciences, Hokkaido University, North-12 West-5, Kita-ku, Sapporo, 060-0812, Japan
| | - Tamotsu Kamishima
- Faculty of Health Sciences, Hokkaido University, North-12 West-5, Kita-ku, Sapporo, 060-0812, Japan.
| |
Collapse
|
11
|
Computer-Based Radiographic Quantification of Joint Space Narrowing Progression Using Sequential Hand Radiographs: Validation Study in Rheumatoid Arthritis Patients from Multiple Institutions. J Digit Imaging 2018; 30:648-656. [PMID: 28378032 DOI: 10.1007/s10278-017-9970-9] [Citation(s) in RCA: 5] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 02/06/2023] Open
Abstract
We have developed a refined computer-based method to detect joint space narrowing (JSN) progression with the joint space narrowing progression index (JSNPI) by superimposing sequential hand radiographs. The purpose of this study is to assess the validity of a computer-based method using images obtained from multiple institutions in rheumatoid arthritis (RA) patients. Sequential hand radiographs of 42 patients (37 females and 5 males) with RA from two institutions were analyzed by a computer-based method and visual scoring systems as a standard of reference. The JSNPI above the smallest detectable difference (SDD) defined JSN progression on the joint level. The sensitivity and specificity of the computer-based method for JSN progression was calculated using the SDD and a receiver operating characteristic (ROC) curve. Out of 314 metacarpophalangeal joints, 34 joints progressed based on the SDD, while 11 joints widened. Twenty-one joints progressed in the computer-based method, 11 joints in the scoring systems, and 13 joints in both methods. Based on the SDD, we found lower sensitivity and higher specificity with 54.2 and 92.8%, respectively. At the most discriminant cutoff point according to the ROC curve, the sensitivity and specificity was 70.8 and 81.7%, respectively. The proposed computer-based method provides quantitative measurement of JSN progression using sequential hand radiographs and may be a useful tool in follow-up assessment of joint damage in RA patients.
Collapse
|
12
|
Okino T, Kamishima T, Lee Sutherland K, Fukae J, Narita A, Ichikawa S, Tanimura K. Radiographic temporal subtraction analysis can detect finger joint space narrowing progression in rheumatoid arthritis with clinical low disease activity. Acta Radiol 2018; 59:460-467. [PMID: 28728431 DOI: 10.1177/0284185117721262] [Citation(s) in RCA: 5] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/17/2022]
Abstract
Background Recent papers suggest that finger joints with positive synovial vascularity (SV) assessed by ultrasonography under clinical low disease activity (CLDA) in rheumatoid arthritis (RA) patients may cause joint space narrowing (JSN) progression. Purpose To investigate the performance of a computer-based method by directly comparing with the conventional scoring method in terms of the detectability of JSN progression in hand radiography of RA patients with CLDA. Material and Methods Fifteen RA patients (13 women, 2 men) with long-term sustained CLDA of >2 years were included. Radiological progression of finger joints was measured or scored using the computer-based method which can detect JSN progression between two radiographic images as the joint space difference index (JSDI), as well as the Genant-modified Sharp score (GSS). We also quantitatively assessed SV of these joints using ultrasonography. Results Out of 270 joints, we targeted 259 finger joints after excluding nine damaged joints (four ankylosis, three complete luxation, and two subluxation) and two improved joints according to the GSS results. The JSDI of finger joints with JSN progression was significantly higher than those without JSN progression ( P = 0.018). The JSDI of finger joints with ultrasonographic SV was significantly higher than those without ultrasonographic SV ( P = 0.004). Progression in JSDI showed stronger associations with ultrasonographic SV than progression in GSS (odds ratio [95% confidence interval]: 7.19 [3.37-15.36] versus 5.84 [2.76-12.33]). Conclusion The computer-based method was comparable to the conventional scoring method regarding the detectability of JSN progression in RA patients with CLDA.
Collapse
Affiliation(s)
- Taichi Okino
- Department of Radiological Technology, Sapporo City General Hospital, Sapporo, Japan
| | | | | | - Jun Fukae
- Hokkaido Medical Center for Rheumatic Diseases, Sapporo, Japan
| | - Akihiro Narita
- Hokkaido Medical Center for Rheumatic Diseases, Sapporo, Japan
| | - Shota Ichikawa
- Department of Radiological Technology, Kurashiki Central Hospital, Kurashiki, Japan
| | | |
Collapse
|
13
|
Platten M, Kisten Y, Kälvesten J, Arnaud L, Forslind K, van Vollenhoven R. Fully automated joint space width measurement and digital X-ray radiogrammetry in early RA. RMD Open 2017; 3:e000369. [PMID: 28879043 PMCID: PMC5574453 DOI: 10.1136/rmdopen-2016-000369] [Citation(s) in RCA: 6] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/26/2016] [Revised: 04/08/2017] [Accepted: 04/16/2017] [Indexed: 01/28/2023] Open
Abstract
Objectives To study fully automated digital joint space width (JSW) and bone mineral density (BMD) in relation to a conventional radiographic scoring method in early rheumatoid arthritis (eRA). Methods Radiographs scored by the modified Sharp van der Heijde score (SHS) in patients with eRA were acquired from the SWEdish FarmacOTherapy study. Fully automated JSW measurements of bilateral metacarpals 2, 3 and 4 were compared with the joint space narrowing (JSN) score in SHS. Multilevel mixed model statistics were applied to calculate the significance of the association between ΔJSW and ΔBMD over 1 year, and the JSW differences between damaged and undamaged joints as evaluated by the JSN. Results Based on 576 joints of 96 patients with eRA, a significant reduction from baseline to 1 year was observed in the JSW from 1.69 (±0.19) mm to 1.66 (±0.19) mm (p<0.01), and BMD from 0.583 (±0.068) g/cm2 to 0.566 (±0.074) g/cm2 (p<0.01). A significant positive association was observed between ΔJSW and ΔBMD over 1 year (p<0.0001). On an individual joint level, JSWs of undamaged (JSN=0) joints were wider than damaged (JSN>0) joints: 1.68 mm (95% CI 1.70 to 1.67) vs 1.54 mm (95% CI 1.63 to 1.46). Similarly the unadjusted multilevel model showed significant differences in JSW between undamaged (1.68 mm (95% CI 1.72 to 1.64)) and damaged joints (1.63 mm (95% CI 1.68 to 1.58)) (p=0.0048). This difference remained significant in the adjusted model: 1.66 mm (95% CI 1.70 to 1.61) vs 1.62 mm (95% CI 1.68 to 1.56) (p=0.042). Conclusions To measure the JSW with this fully automated digital tool may be useful as a quick and observer-independent application for evaluating cartilage damage in eRA. Trial registration number NCT00764725.
Collapse
Affiliation(s)
- Michael Platten
- Department of Medicine, Unit for Clinical Therapy Research, Inflammatory Diseases (ClinTRID), Karolinska Institute, Stockholm, Sweden
| | - Yogan Kisten
- Department of Medicine, Unit for Clinical Therapy Research, Inflammatory Diseases (ClinTRID), Karolinska Institute, Stockholm, Sweden
| | - Johan Kälvesten
- Medicine and Health Sciences, Center for Medical Image Science and Visualization (CMIV), Linköping University, Linköping, Sweden.,Sectra AB, Linköping, Sweden
| | - Laurent Arnaud
- Department of Medicine, Unit for Clinical Therapy Research, Inflammatory Diseases (ClinTRID), Karolinska Institute, Stockholm, Sweden
| | - Kristina Forslind
- Department of Medicine, Section of Rheumatology, Helsingborg's Hospital, Helsingborg, Sweden.,Department of Clinical Sciences, Section of Rheumatology, Lund University, Helsingborg, Sweden
| | - Ronald van Vollenhoven
- Department of Medicine, Unit for Clinical Therapy Research, Inflammatory Diseases (ClinTRID), Karolinska Institute, Stockholm, Sweden.,Departments of AMC, READE and VUmc, Amsterdam Rheumatology & Immunology Center (ARC), Amsterdam, Netherlands
| |
Collapse
|
14
|
Ichikawa S, Kamishima T, Sutherland K, Kasahara H, Shimizu Y, Fujimori M, Yasojima N, Ono Y, Kaneda T, Koike T. Semi-Automated Quantification of Finger Joint Space Narrowing Using Tomosynthesis in Patients with Rheumatoid Arthritis. J Digit Imaging 2017; 30:369-375. [PMID: 28105533 DOI: 10.1007/s10278-017-9949-6] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/20/2022] Open
Abstract
The purpose of the study is to validate the semi-automated method using tomosynthesis images for the assessment of finger joint space narrowing (JSN) in patients with rheumatoid arthritis (RA), by using the semi-quantitative scoring method as the reference standard. Twenty patients (14 females and 6 males) with RA were included in this retrospective study. All patients underwent radiography and tomosynthesis of the bilateral hand and wrist. Two rheumatologists and a radiologist independently scored JSN with two modalities according to the Sharp/van der Heijde score. Two observers independently measured joint space width on tomosynthesis images using an in-house semi-automated method. More joints with JSN were revealed with tomosynthesis score (243 joints) and the semi-automated method (215 joints) than with radiography (120 joints), and the associations between tomosynthesis scores and radiography scores were demonstrated (P < 0.001). There was significant, negative correlation between measured joint space width and tomosynthesis scores with r = -0.606 (P < 0.001) in metacarpophalangeal joints and r = -0.518 (P < 0.001) in proximal interphalangeal joints. Inter-observer and intra-observer agreement of the semi-automated method using tomosynthesis images was in almost perfect agreement with intra-class correlation coefficient (ICC) values of 0.964 and 0.963, respectively. The semi-automated method using tomosynthesis images provided sensitive, quantitative, and reproducible measurement of finger joint space in patients with RA.
Collapse
Affiliation(s)
- Shota Ichikawa
- Graduate School of Health Sciences, Hokkaido University, North-12 West-5, Kita-ku, Sapporo, 060-0812, Japan
| | - Tamotsu Kamishima
- Faculty of Health Sciences, Hokkaido University, North-12 West-5, Kita-ku, Sapporo, 060-0812, Japan.
| | - Kenneth Sutherland
- Graduate School of Medicine, Hokkaido University, North-15 West-7, Kita-ku, Sapporo, 060-8638, Japan
| | - Hideki Kasahara
- Department of Rheumatology, Sapporo Medical Center NTT EC, South-1 West-15, Chuo-ku, Sapporo, 060-0061, Japan
| | - Yuka Shimizu
- Division of Rheumatology, Endocrinology and Nephrology, Graduate School of Medicine, Hokkaido University, Kita-15, Nishi-7, Kita-ku, Sapporo, 060-8638, Japan
| | - Motoshi Fujimori
- Department of Health Sciences, Hokkaido University, North-12 West-5, Kita-ku, Sapporo, 060-0812, Japan
| | - Nobutoshi Yasojima
- Department of Radiology, Sapporo Medical Center NTT EC, South-1 West-15, Chuo-ku, Sapporo, 060-0061, Japan
| | - Yohei Ono
- Department of Radiology, Sapporo Medical Center NTT EC, South-1 West-15, Chuo-ku, Sapporo, 060-0061, Japan
| | - Takahiko Kaneda
- Graduate School of Health Sciences, Hokkaido University, North-12 West-5, Kita-ku, Sapporo, 060-0812, Japan
| | - Takao Koike
- Sapporo Medical Center NTT EC, South-1 West-15, Chuo-ku, Sapporo, 060-0061, Japan
| |
Collapse
|
15
|
Schenk O, Huo Y, Vincken KL, van de Laar MA, Kuper IHH, Slump KCH, Lafeber FPJG, Bernelot Moens HJ. Validation of automatic joint space width measurements in hand radiographs in rheumatoid arthritis. J Med Imaging (Bellingham) 2016; 3:044502. [PMID: 27921071 DOI: 10.1117/1.jmi.3.4.044502] [Citation(s) in RCA: 7] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/06/2016] [Accepted: 11/01/2016] [Indexed: 11/14/2022] Open
Abstract
Computerized methods promise quick, objective, and sensitive tools to quantify progression of radiological damage in rheumatoid arthritis (RA). Measurement of joint space width (JSW) in finger and wrist joints with these systems performed comparable to the Sharp-van der Heijde score (SHS). A next step toward clinical use, validation of precision and accuracy in hand joints with minimal damage, is described with a close scrutiny of sources of error. A recently developed system to measure metacarpophalangeal (MCP) and proximal interphalangeal (PIP) joints was validated in consecutive hand images of RA patients. To assess the impact of image acquisition, measurements on radiographs from a multicenter trial and from a recent prospective cohort in a single hospital were compared. Precision of the system was tested by comparing the joint space in mm in pairs of subsequent images with a short interval without progression of SHS. In case of incorrect measurements, the source of error was analyzed with a review by human experts. Accuracy was assessed by comparison with reported measurements with other systems. In the two series of radiographs, the system could automatically locate and measure 1003/1088 (92.2%) and 1143/1200 (95.3%) individual joints, respectively. In joints with a normal SHS, the average (SD) size of MCP joints was [Formula: see text] and [Formula: see text] in the two series of radiographs, and of PIP joints [Formula: see text] and [Formula: see text]. The difference in JSW between two serial radiographs with an interval of 6 to 12 months and unchanged SHS was [Formula: see text], indicating very good precision. Errors occurred more often in radiographs from the multicenter cohort than in a more recent series from a single hospital. Detailed analysis of the 55/1125 (4.9%) measurements that had a discrepant paired measurement revealed that variation in the process of image acquisition (exposure in 15% and repositioning in 57%) was a more frequent source of error than incorrect delineation by the software (25%). Various steps in the validation of an automated measurement system for JSW of MCP and PIP joints are described. The use of serial radiographs from different sources, with a short interval and limited damage, is helpful to detect sources of error. Image acquisition, in particular repositioning, is a dominant source of error.
Collapse
Affiliation(s)
- Olga Schenk
- University of Twente , MIRA Institute for Biomedical Technology and Technical Medicine, Drienerlolaan 5, 7522 NB, Enschede, The Netherlands
| | - Yinghe Huo
- University Medical Center Utrecht, Image Sciences Institute, Heidelberglaan 100, 3584 CX, Utrecht, The Netherlands; University Medical Center Utrecht, Department of Rheumatology and Clinical Immunology, Heidelberglaan 100, 3584 CX, Utrecht, The Netherlands
| | - Koen L Vincken
- University Medical Center Utrecht , Image Sciences Institute, Heidelberglaan 100, 3584 CX, Utrecht, The Netherlands
| | - Mart A van de Laar
- Department of Rheumatology , Medisch Spectrum Twente, Koningsplein 1, 7512 KZ, Enschede, The Netherlands
| | - Ina H H Kuper
- Department of Rheumatology , Medisch Spectrum Twente, Koningsplein 1, 7512 KZ, Enschede, The Netherlands
| | - Kees C H Slump
- University of Twente , MIRA Institute for Biomedical Technology and Technical Medicine, Drienerlolaan 5, 7522 NB, Enschede, The Netherlands
| | - Floris P J G Lafeber
- University Medical Center Utrecht , Department of Rheumatology and Clinical Immunology, Heidelberglaan 100, 3584 CX, Utrecht, The Netherlands
| | - Hein J Bernelot Moens
- Department of Rheumatology , Ziekenhuisgroep Twente, Geerdinksweg 141, 7555 DL, Hengelo, The Netherlands
| |
Collapse
|
16
|
Damman W, Kortekaas MC, Stoel BC, van 't Klooster R, Wolterbeek R, Rosendaal FR, Kloppenburg M. Sensitivity-to-change and validity of semi-automatic joint space width measurements in hand osteoarthritis: a follow-up study. Osteoarthritis Cartilage 2016; 24:1172-9. [PMID: 26876778 DOI: 10.1016/j.joca.2016.02.002] [Citation(s) in RCA: 7] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 06/26/2015] [Revised: 01/11/2016] [Accepted: 02/07/2016] [Indexed: 02/02/2023]
Abstract
OBJECTIVE To assess sensitivity-to-change and validity of longitudinal quantitative semi-automatic joint space width (JSW) measurements and to compare this method with semi-quantitative joint space narrowing (JSN) scoring in hand osteoarthritis (OA) patients. DESIGN Baseline and 2-year follow-up radiographs of 56 hand OA patients (mean age 62 years, 86% women) were used. JSN was scored 0-3 using the Osteoarthritis Research Society International atlas and JSW was quantified in millimetres (mm) in the second to fifth distal, proximal interphalangeal and metacarpal joints (DIPJs, PIPJs, MCPJs). Sensitivity-to-change was evaluated by calculating Standardized Response Means (SRMs). Change in JSW or JSN above the Smallest Detectable Difference (SDD) defined progression on joint level. To assess construct validity, progressed joints were compared by cross-tabulation and by associating baseline ultrasound variables with progression (using generalized estimating equations, adjusting for age and sex). RESULTS The JSW method detected statistically significant mean changes over 2.6 years (-0.027 mm (95%CI -0.01; -0.04), -0.024 mm (-0.01; -0.03), -0.021 mm (-0.01; -0.03) for DIPJs, PIPJs, MCPJs, respectively). Sensitivity-to-change was low (SRMs: 0.174, 0.168, 0.211, respectively). 9.1% (121/1336) of joints progressed in JSW, but 3.6% (48/1336) widened. 83 (6.2%) joints progressed in JSW only, 36 (2.7%) in JSN only and 37 (2.8%) in both methods. Progression in JSW showed weaker associations with baseline inflammatory ultrasound features than progression in JSN. CONCLUSIONS Assessment of progression in hand OA defined by JSW measurements is possible, but performs less well than progression defined by JSN scoring. Therefore, the value of JSW measurements in hand OA clinical trials remains questionable.
Collapse
Affiliation(s)
- W Damman
- Department of Rheumatology, Leiden University Medical Center (LUMC), Leiden, The Netherlands.
| | - M C Kortekaas
- Department of Rheumatology, Leiden University Medical Center (LUMC), Leiden, The Netherlands
| | - B C Stoel
- Division of Image Processing, Department of Radiology, LUMC, Leiden, The Netherlands
| | - R van 't Klooster
- Division of Image Processing, Department of Radiology, LUMC, Leiden, The Netherlands
| | - R Wolterbeek
- Department of Medical Statistics, LUMC, Leiden, The Netherlands
| | - F R Rosendaal
- Department of Clinical Epidemiology, LUMC, Leiden, The Netherlands
| | - M Kloppenburg
- Department of Rheumatology, Leiden University Medical Center (LUMC), Leiden, The Netherlands
| |
Collapse
|
17
|
Pfeil A, Oelzner P, Bornholdt K, Hansch A, Lehmann G, Renz DM, Wolf G, Böttcher J. Joint damage in rheumatoid arthritis: assessment of a new scoring method. Arthritis Res Ther 2013; 15:R27. [PMID: 23406946 PMCID: PMC3672701 DOI: 10.1186/ar4163] [Citation(s) in RCA: 19] [Impact Index Per Article: 1.6] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/12/2012] [Revised: 01/10/2013] [Accepted: 02/06/2013] [Indexed: 01/24/2023] Open
Abstract
INTRODUCTION The aim of this study was to assess a novel approach for the quantification of finger joint space narrowing and joint destruction in patients with rheumatoid arthritis (RA) focusing on the peripheral hand articulations. METHODS A total of 280 patients with verified RA underwent computerized semi-automated measurements of joint space distance at the finger articulations based on radiographs. The Z-Score, which can differentiate between joint space alterations caused by RA versus age/gender-related changes, was calculated as a comparative parameter. The severity of joint space narrowing was also quantified by the Sharp Score. Sensitivity and specificity of the Z-Score (based on joint space widths differentiated for each peripheral finger joint) were evaluated to reveal the potential for the occurrence of erosions. Additionally, the potential of the Z-Score regarding the differentiation of therapeutic effects on joint space widths in patients under a therapy of methotrexate versus leflunomide was performed. RESULTS The Z-Scores of finger articulations in patients with RA were generally decreased. Metacarpal-phalangeal (MCP) joint articulations showed a continuous significant decline of -1.65±0.30 standard deviations dependent on the Sharp Score. The proximal-interphalangeal joints also revealed a significant reduction of the Z-Score (-0.96±0.31 standard deviations). The sensitivity and specificity of MCP joint space distance for the detection of erosions were 85.4% versus 55.2%. The Sharp Score for joint space narrowing was not able to detect different treatments, whereas an accentuated stabilization of joint space narrowing could be identified for the Z-Score of the MCP joints in patients treated with leflunomide and methotrexate. CONCLUSION The Z-Scoring method based on computer-aided analysis of joint space widths was able to reliably quantify severity-dependent joint space narrowing in RA patients. In the future, calculation of a Z-Score based on gender-specific and age-specific reference data shows the potential for a surrogate marker of RA progression that comprehends the early identification of patients with RA, and in particular those with erosive course of the disease, enabling a timely therapeutic strategy for cartilage protection.
Collapse
Affiliation(s)
- Alexander Pfeil
- Department of Internal Medicine III, Jena University Hospital - Friedrich Schiller University Jena, Erlanger Allee 101, 07747 Jena, Germany
| | - Peter Oelzner
- Department of Internal Medicine III, Jena University Hospital - Friedrich Schiller University Jena, Erlanger Allee 101, 07747 Jena, Germany
| | - Klaus Bornholdt
- Sanofi-Aventis Deutschland GmbH, Potsdamer Straße 8, 10785 Berlin, Germany
| | - Andreas Hansch
- Institute of Diagnostic and Interventional Radiology, Jena University Hospital - Friedrich Schiller University Jena, Erlanger Allee 101, 07747 Jena, Germany
| | - Gabriele Lehmann
- Department of Internal Medicine III, Jena University Hospital - Friedrich Schiller University Jena, Erlanger Allee 101, 07747 Jena, Germany
| | - Diane M Renz
- Department of Diagnostic Radiology, Charité University Medicine Berlin, Campus Virchow Clinic, Augustenburger Platz 1, 13353 Berlin, Germany
| | - Gunter Wolf
- Department of Internal Medicine III, Jena University Hospital - Friedrich Schiller University Jena, Erlanger Allee 101, 07747 Jena, Germany
| | - Joachim Böttcher
- Institute of Diagnostic and Interventional Radiology, SRH Wald-Klinikum Gera, Straße des Friedens 122, 07548 Gera, Germany
| |
Collapse
|
18
|
Pfeil A, Renz DM, Hansch A, Kainberger F, Lehmann G, Malich A, Wolf G, Böttcher J. The usefulness of computer-aided joint space analysis in the assessment of rheumatoid arthritis. Joint Bone Spine 2012; 80:380-5. [PMID: 23245655 DOI: 10.1016/j.jbspin.2012.10.022] [Citation(s) in RCA: 17] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/26/2012] [Accepted: 10/26/2012] [Indexed: 11/15/2022]
Abstract
OBJECTIVE Computer-aided joint space analysis (CAJSA) is a newly developed technique for the measurement of radiogeometrically detectable joint space widths of the metacarpal-phalangeal (JSD-MCP) and proximal-interphalangeal articulations (JSD-PIP). The aim of this study was to verify the sensitivity and specificity of these CAJSA measurements in the assessment of established RA. METHODS Four hundred and fifty-eight participants (248 healthy subjects, 210 RA patients) underwent computerized semi-automated measurements of the JSD-MCP and JSD-PIP articulations (CAJSA, Radiogrammetry Kit, Version 1.3.6) based on digitally performed radiographs. The Sharp joint space narrowing score was also performed to determine RA-related joint space narrowing. RESULTS The significant severity-dependent reduction for JSD-MCP was -44.0% and for JSD-PIP, -25.94% between Sharp scores 0 and 3. The sensitivity and specificity of JSD-MCP (total) was 88.1% versus 77.8%, respectively (AUC = 0.920; P < 0.001). Furthermore, JSD-PIP (total) revealed a lower sensitivity and specificity with 61.4% and 88.7% (AUC = 0.878; P < 0.001). CONCLUSION The CAJSA method presented a reliable assessment of disease-related joint space narrowing in patients suffering from RA with excellent sensitivity and specificity. By providing quantitative data, other scoring methods could be significantly improved, and thereby the accuracy of the diagnosis and a better therapeutic evaluation could be achieved.
Collapse
Affiliation(s)
- Alexander Pfeil
- Department of Internal Medicine III, Jena University Hospital, Friedrich Schiller University Jena, Erlanger Allee 101, 07747 Jena, Germany.
| | | | | | | | | | | | | | | |
Collapse
|
19
|
Summers RM. Evaluation of computer-aided detection devices: consensus is developing. Acad Radiol 2012; 19:377-9. [PMID: 22444672 DOI: 10.1016/j.acra.2012.01.010] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.1] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/27/2012] [Revised: 01/27/2012] [Accepted: 01/30/2012] [Indexed: 10/28/2022]
|
20
|
Improved Fuzzy Entropy Algorithm for X-Ray Pictures Preprocessing. ARTIFICIAL INTELLIGENCE AND SOFT COMPUTING 2012. [DOI: 10.1007/978-3-642-29350-4_32] [Citation(s) in RCA: 4] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 02/09/2023]
|
21
|
Huétink K, van 't Klooster R, Kaptein BL, Watt I, Kloppenburg M, Nelissen RGHH, Reiber JHC, Stoel BC. Automatic radiographic quantification of hand osteoarthritis; accuracy and sensitivity to change in joint space width in a phantom and cadaver study. Skeletal Radiol 2012; 41:41-9. [PMID: 21311883 PMCID: PMC3223586 DOI: 10.1007/s00256-011-1110-x] [Citation(s) in RCA: 9] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 09/02/2010] [Revised: 01/06/2011] [Accepted: 01/18/2011] [Indexed: 02/02/2023]
Abstract
OBJECTIVE To validate a newly developed quantification method that automatically detects and quantifies the joint space width (JSW) in hand radiographs. Repeatability, accuracy and sensitivity to changes in JSW were determined. The influence of joint location and joint shape on the measurements was tested. METHODS A mechanical micrometer set-up was developed to define and adjust the true JSW in an acrylic phantom joint and in human cadaver-derived phalangeal joints. Radiographic measurements of the JSW were compared to the true JSW. Repeatability, systematic error (accuracy) and sensitivity (defined as the smallest detectable difference (SDD)) were determined. The influence of joint position on the JSW measurement was assessed by varying the location of the acrylic phantom on the X-ray detector with respect to the X-ray beam and the influence of joint shape was determined by using morphologically different human cadaver joints. RESULTS The mean systematic error was 0.052 mm in the phantom joint and 0.210 mm in the cadaver experiment. In the phantom experiments, the repeatability was high (SDD = 0.028 mm), but differed slightly between joint locations (p = 0.046), and a change in JSW of 0.037 mm could be detected. Dependent of the joint shape in the cadaver hand, a change in JSW between 0.018 and 0.047 mm could be detected. CONCLUSIONS The automatic quantification method is sensitive to small changes in JSW. Considering the published data of JSW decline in the normal and osteoarthritic population, the first signs of OA progression with this method can be detected within 1 or 2 years.
Collapse
Affiliation(s)
- Kasper Huétink
- Department of Radiology, Leiden University Medical Center, 9600, 2300, RC Leiden, The Netherlands.
| | | | | | | | | | | | | | | |
Collapse
|
22
|
Kwok WY, Bijsterbosch J, Malm SH, Biermasz NR, Huetink K, Nelissen RG, Meulenbelt I, Huizinga TWJ, van 't Klooster R, Stoel BC, Kloppenburg M. Validity of joint space width measurements in hand osteoarthritis. Osteoarthritis Cartilage 2011; 19:1349-55. [PMID: 21924370 DOI: 10.1016/j.joca.2011.08.011] [Citation(s) in RCA: 9] [Impact Index Per Article: 0.6] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 01/07/2011] [Revised: 08/24/2011] [Accepted: 08/29/2011] [Indexed: 02/02/2023]
Abstract
OBJECTIVE To investigate the validity of joint space width (JSW) measurements in millimeters (mm) in hand osteoarthritis (OA) patients by comparison to controls, grading of joint space narrowing (JSN), and clinical features. METHODS Hand radiographs of 235 hand OA patients (mean age 65 years, 83% women) and 471 controls were used. JSW was measured with semi-automated image analysis software in the distal, proximal interphalangeal and metacarpal joints (DIPJs, PIPJs and MCPJs). JSN (grade 0-3) was assessed using the osteoarthritis research society international (OARSI) atlas. Associations between the two methods and clinical determinants (presence of pain, nodes and/or erosions, decreased mobility) were assessed using Generalized Estimating Equations with adjustments for age, sex, body mass index (BMI) and mean width of proximal phalanx. RESULTS JSW was measured in 5631 joints with a mean JSW of 0.98 mm (standard deviation (SD) 0.21), being the smallest for DIPJs (0.70 (SD 0.25)) and largest for MCPJs (1.40 (SD 0.25)). The JSN=0 group had a mean JSW of 1.28 mm (SD 0.34), the JSN=3 group 0.17 mm (SD 0.23). Controls had larger JSW than hand OA patients (P-value<0.001). In hand OA, females had smaller JSW than men (β -0.08, (95% confidence interval (95% CI) -0.15 to -0.01)) and lower JSW was associated with the presence of pain, nodes, erosions and decreased mobility (adjusted β -0.21 (95% CI -0.27, -0.16), -0.37 (-0.40, -0.34), -0.61 (-0.68, -0.54) and -0.46 (-0.68, -0.24) respectively). These associations were similar for JSN in grades. CONCLUSION In hand OA the quantitative JSW measurement is a valid method to measure joint space and shows a good relation with clinical features.
Collapse
Affiliation(s)
- W Y Kwok
- Department of Rheumatology, Leiden University Medical Center, Leiden, The Netherlands.
| | | | | | | | | | | | | | | | | | | | | |
Collapse
|
23
|
Pfeil A, Hansch A, Sommerfeld J, Fröber R, Renz DM, Lehmann G, Malich A, Wolf G, Böttcher J. Reproducibility and influence of hand rotation on computer-aided joint space analysis. Joint Bone Spine 2011; 79:384-8. [PMID: 21963809 DOI: 10.1016/j.jbspin.2011.07.011] [Citation(s) in RCA: 7] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/10/2011] [Accepted: 07/25/2011] [Indexed: 01/01/2023]
Abstract
OBJECTIVES Computer-aided joint space analysis (CAJSA) is a recently developed, semi-automated tool to aid in the measurement of joint space margins based on hand radiographs. The objective of this study is to verify the potential effect of hand rotation during X-ray imaging on the measurement of joint space width using CAJSA and to evaluate the reproducibility of the CAJSA technique in healthy subjects and in patients with rheumatoid arthritis. METHODS All joint space distance (JSD) measurements were performed using CAJSA-technology at the metacarpophalangeal articulation based on conventional and digital hand radiographs. RESULTS I. Hand rotation showed an effect on the reproducibility with CV ranging between 0.39% (angulation 1°) and 1.66% (angulation 19°). II. Regarding the overall reproducibility of the CAJSA method, the intra-radiograph reproducibility of JSD was calculated with CV=0.54% for conventional images and CV=0.38% for digital images. The inter-radiograph reproducibility error was observed with CV=0.66% (conventional images) and CV=0.63% (digital images). III. The study revealed a reproducibility for CAJSA measurements in RA ranging between 0.37% (JSD-MCP ring finger; van der Heijde-modification of the Sharp method score 1) to 1.37% (JSD-MCP index finger; van der Heijde-modification of the Sharp method score 3). CONCLUSION CAJSA measures JSD at the metacarpophalangeal articulation with high reproducibility in healthy subjects and in patients with differing stages of rheumatoid arthritis. Additional findings show that hand rotation during X-ray imaging has an impact on the CAJSA measurements; thus avoiding acquisition of hand radiographs with a rotation error of more than 15 degrees can be recommended.
Collapse
|
24
|
Bracco P, Debernardi C, Piancino MG, Cirigliano MF, Salvetti G, Bazzichi L, De Feo F, Bosco M. Evaluation of the stomatognathic system in patients with rheumatoid arthritis according to the research diagnostic criteria for temporomandibular disorders. Cranio 2010; 28:181-6. [PMID: 20806736 DOI: 10.1179/crn.2010.025] [Citation(s) in RCA: 6] [Impact Index Per Article: 0.4] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/31/2022]
Abstract
The aim of this study was to investigate the clinical features of stomatognathic dysfunction in patients with rheumatoid arthritis (RA). The study sample consisted of 40 patients with RA (34 female, 6 male), mean age 44 years, recruited at the Rheumatology Division of the Department of Internal Medicine, University of Pisa, Italy. The inclusion criteria were diagnosis of RA according to the criteria of the American Rheumatism Association (ARA). In the study, 82.5% (n=33) of patients affected by RA satisfied at least the criteria of one diagnosis of temporomandibular disorders (TMD), according to the Research Diagnostic Criteria for Temporomandibular Disorders (RDC/TMD). The results are in agreement with the literature and the prevalence of such involvement ranges between 53% and 94% of patients. Several studies reported an involvement of the stomatognathic system in RA. In fact, RA can affect the temporomandibular joint as much as any other synovial joint. A more thorough analysis is required for a multidisciplinary approach to gnathological patients, including assessment by a rheumatologist. This issue and its epidemiologic relevance need further scientific research. Dentistry has a fundamental role in this process since patients who present with a systemic disease such as RA can be recognized and intercepted and referred to medical specialists, i.e., rheumatologists, to provide a diagnosis and therapy.
Collapse
Affiliation(s)
- Pietro Bracco
- Dept. of Orthodontics and Gnathology, Dental School, University of Turin, Via Nizza 230, 10126 Torino, Italy.
| | | | | | | | | | | | | | | |
Collapse
|
25
|
Pfeil A, Sommerfeld J, Fröber R, Lehmann G, Malich A, Hansch A, Wolf G, Böttcher J. Feasibility study of semi-automated measurements of finger joint space widths. Rheumatol Int 2010; 31:1349-54. [PMID: 20401484 DOI: 10.1007/s00296-010-1468-4] [Citation(s) in RCA: 8] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/16/2010] [Accepted: 03/12/2010] [Indexed: 11/26/2022]
Abstract
The purpose of this study is to evaluate technical feasibility based on image capturing conditions (film-focus distance (FFD), film sensitivity, film brand, exposure level and tube voltage) that potentially alter radiographs and consequently may influence the semi-automated measurement of joint space distance (JSD) by computer-aided joint space analysis (CAJSA) in rheumatoid arthritis and osteoarthritis. The radiographs of a left hand (deceased man) were acquired under systematically changing image capturing conditions (exposure level: 4-8 mAs; FFD: 90-130 cm; film sensitivity: 200/400 and tube voltage: 40-52 kV with different image modalities: conventional radiographs, original digital radiographs, digital print-outs). All JSD-measurements were performed with the CAJSA-technology (Radiogrammetry Kit, Version 1.3.6; Sectra; Sweden) at the metacarpal-phalangeal articulation. JSD-analysis was not influenced by changes of FFD, exposure level, film sensitivity or film brand. JSD showed significant variation caused by tube voltage (conventional: CV = 1.913% for Agfa and CV = 2.448% for Kodak; digital: CV = 0.741% for Philips print-outs and CV = 0.620% with original digital images versus CV = 2.185% for Siemens print-outs and 0.951% with original digital images). Computer-aided joint space analysis for JSD-measurements is unaffected by the following image capturing parameters: film-focus distance, film sensitivity, film brand and exposure level. An influence of tube voltage was detected in a lesser extent for original digital images compared to the printed digital as well as conventional versions. Consequently, a standardized tube voltage is essential for accurate reproductions of CAJSA-measurements in rheumatoid arthritis and osteoarthritis.
Collapse
Affiliation(s)
- Alexander Pfeil
- Department of Internal Medicine III, Friedrich-Schiller-University Jena, Erlanger Allee 101, 07747, Jena, Germany.
| | | | | | | | | | | | | | | |
Collapse
|
26
|
Hand Radiograph Analysis and Joint Space Location Improvement for Image Interpretation. ACTA ACUST UNITED AC 2010. [DOI: 10.2478/v10149-010-0003-4] [Citation(s) in RCA: 19] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/20/2022]
|
27
|
PFEIL ALEXANDER, SCHÄFER MAXL, LEHMANN GABRIELE, SEIDL BETTINAE, EIDNER THORSTEN, MALICH ANSGAR, RENZ DIANEM, OELZNER PETER, HANSCH ANDREAS, WOLF GUNTER, HEIN GERT, KAISER WERNERA, BÖTTCHER JOACHIM. Implementation of Z-Scores as an Age- and Sex-independent Parameter for Estimating Joint Space Widths in Rheumatoid Arthritis. J Rheumatol 2009; 36:717-23. [DOI: 10.3899/jrheum.080651] [Citation(s) in RCA: 11] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/01/2023]
Abstract
Objective.To compare normative data of joint space distances (JSD) with the JSD of patients with rheumatoid arthritis (RA) as measured by computer-aided joint space analysis (CAJSA) at the metacarpophalangeal (MCP) articulations, and to differentiate age- and sex-related alterations from the disease-related joint space narrowing.Methods.In total, 256 healthy subjects and 248 patients with verified RA (following revised ACR criteria) underwent computerized semiautomated measurements of JSD (CAJSA, version 1.3.6) at the MCP articulation (JSD-MCP) based on digital radiographs. The Z-score, a comparative parameter that differentiates joint space alterations caused by RA-related cartilage destruction from age- and sex-related changes, was calculated.Results.Our data showed a relationship between measured joint space widths (MCP total and MCP thumb to little finger) and age for healthy subjects and also the RA group. The RA group revealed an age-related joint space narrowing that was surpassed by the RA-related narrowing of joint space widths classified by Sharp joint space narrowing score and resulting in smaller Z-scores for RA patients.Conclusion.The CAJSA technique seems to distinguish age-related JSD changes in healthy volunteers from RA-induced alterations. In addition the Z-score was also able to differentiate RA-dependent narrowing of JSD. Calculation of the Z-scores based on sex- and age-specific reference data may facilitate earlier identification of patients with RA, allowing initiation of a more optimal, individually adapted therapeutic strategy.
Collapse
|
28
|
Pfeil A, Hansch A, Lehmann G, Eidner T, Schäfer ML, Oelzner P, Renz DM, Wolf G, Hein G, Kaiser WA, Böttcher J. Impact of sex, age, body mass index and handedness on finger joint space width in patients with prolonged rheumatoid arthritis using computer-aided joint space analysis. Rheumatol Int 2008; 29:517-24. [DOI: 10.1007/s00296-008-0728-z] [Citation(s) in RCA: 11] [Impact Index Per Article: 0.6] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/05/2008] [Accepted: 09/12/2008] [Indexed: 11/24/2022]
|