1
|
Cicone F, Sarnelli A, Guidi C, Belli ML, Ferrari ME, Wahl R, Cremonesi M, Paganelli G. Dosimetric Approaches for Radioimmunotherapy of Non-Hodgkin Lymphoma in Myeloablative Setting. Semin Nucl Med 2022; 52:191-214. [PMID: 34996594 DOI: 10.1053/j.semnuclmed.2021.11.001] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 02/06/2023]
Abstract
Radioimmunotherapy (RIT) is a safe and active treatment available for non-Hodgkin lymphomas (NHLs). In particular, two monoclonal antibodies raised against CD20, that is Zevalin (90Y-ibritumomab-tiuxetan) and Bexxar (131I-tositumomab) received FDA approval for the treatment of relapsing/refractory indolent or transformed NHLs. RIT is likely the most effective and least toxic anticancer agent in NHLs. However, its use in the clinical setting is still debated and, in case of relapse after optimized rituximab-containing regimens, the efficacy of RIT at standard dosage is suboptimal. Thus, clinical trials were based on the hypothesis that the inclusion of RIT in myeloablative conditioning would allow to obtain improved efficacy and toxicity profiles when compared to myeloablative total-body irradiation and/or high-dose chemotherapy regimens. Standard-activity RIT has a safe toxicity profile, and the utility of pretherapeutic dosimetry in this setting can be disputed. In contrast, dose-escalation clinical protocols require the assessment of radiopharmaceutical biodistribution and dosimetry before the therapeutic injection, as dose constrains for critical organs may be exceeded when RIT is administered at high activities. The aim of the present study was to review and discuss the internal dosimetry protocols that were adopted for non-standard RIT administration in the myeloablative setting before hematopoietic stem cell transplantation in patients with NHLs.
Collapse
Affiliation(s)
- Francesco Cicone
- Department of Experimental and Clinical Medicine, and Neuroscience Research Centre, PET/RM Unit, "Magna Graecia" University of Catanzaro, Catanzaro, Italy; Nuclear Medicine Unit, University Hospital "Mater Domini", Catanzaro, Italy
| | - Anna Sarnelli
- Medical Physics Unit, IRCCS Istituto Romagnolo per lo Studio dei Tumori (IRST) "Dino Amadori", Meldola, Italy.
| | - Claretta Guidi
- Medical Physics Unit, IRCCS Istituto Romagnolo per lo Studio dei Tumori (IRST) "Dino Amadori", Meldola, Italy
| | - Maria Luisa Belli
- Medical Physics Unit, IRCCS Istituto Romagnolo per lo Studio dei Tumori (IRST) "Dino Amadori", Meldola, Italy
| | | | - Richard Wahl
- Mallinckrodt Institute of Radiology, Washington University School of Medicine, St. Louis, MO
| | - Marta Cremonesi
- Radiation Research Unit, IEO European Institute of Oncology IRCCS, Milan, Italy
| | - Giovanni Paganelli
- Nuclear Medicine Unit, IRCCS Istituto Romagnolo per lo Studio dei Tumori (IRST) "Dino Amadori", Meldola, Italy
| |
Collapse
|
2
|
Pettinato C, Richetta E, Cremonesi M. Dosimetry with single photon emission tomography (SPECT). Nucl Med Mol Imaging 2022. [DOI: 10.1016/b978-0-12-822960-6.00173-3] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/28/2022] Open
|
3
|
Auditore L, Pistone D, Amato E, Italiano A. Monte Carlo methods in nuclear medicine. Nucl Med Mol Imaging 2022. [DOI: 10.1016/b978-0-12-822960-6.00136-8] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/18/2022] Open
|
4
|
Cicone F, Gnesin S, Cremonesi M. Dosimetry of nuclear medicine therapies: current controversies and impact on treatment optimization. THE QUARTERLY JOURNAL OF NUCLEAR MEDICINE AND MOLECULAR IMAGING : OFFICIAL PUBLICATION OF THE ITALIAN ASSOCIATION OF NUCLEAR MEDICINE (AIMN) [AND] THE INTERNATIONAL ASSOCIATION OF RADIOPHARMACOLOGY (IAR), [AND] SECTION OF THE SOCIETY OF... 2021; 65:327-332. [PMID: 34881850 DOI: 10.23736/s1824-4785.21.03418-x] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 01/07/2023]
Abstract
Nuclear medicine therapeutic procedures have considerably expanded over the last few years, and their number is expected to grow exponentially in the future. Internal dosimetry has significantly developed as well, but has not yet been uniformly accepted as a valuable tool for prediction of therapeutic efficacy and toxicity. In this paper, we briefly summarize some of the arguments about the implementation of internal dosimetry in clinical practice. In addition, we provide a few examples of radionuclide anticancer therapies for which internal dosimetry demonstrated a significant impact on treatment optimization and patient outcome.
Collapse
Affiliation(s)
- Francesco Cicone
- PET/RM Unit, Department of Experimental and Clinical Medicine, and Neuroscience Research Center, Magna Graecia University of Catanzaro, Catanzaro, Italy - .,Unit of Nuclear Medicine, Mater Domini University Hospital, Catanzaro, Italy - .,University of Lausanne, Lausanne, Switzerland -
| | - Silvano Gnesin
- Institute of Radiation Physics, Lausanne University Hospital, Lausanne, Switzerland
| | - Marta Cremonesi
- Unit of Radiation Research, Department of Medical Imaging and Radiation Sciences, IRCCS European Institute of Oncology, Milan, Italy
| |
Collapse
|
5
|
Fisher DR. Perspectives on Internal Dosimetry for Optimized Radionuclide Therapy. Cancer Biother Radiopharm 2021; 37:161-163. [PMID: 34569812 DOI: 10.1089/cbr.2021.0318] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/12/2022] Open
Abstract
Abstract A balanced approach to radiopharmaceutical dosimetry involves personalized dosimetry. Planar quantitative imaging can be practical, reliable, and relatively cost-effective. Therapy dose optimization can be achieved for the individual patient using a straightforward tracer study to determine patient-specific biokinetics at three or more imaging time points for organs that assimilate the radiopharmaceutical. Two-dimensional quantitative imaging may be supported and calibrated using a 3D SPECT/CT measurement for the dose-limiting organ at a single time point. Organ volumes are needed from CT images. Measurements require special attention for consistency in camera-to-patient distancing, region-of-interest delineation, and attenuation correction, and operators need training and experience well beyond the requirements for standard nuclear medicine scintigraphy. As with external beam therapy, reimbursement codes are needed to support treatment-planning costs. Postinfusion tumor dosimetry can be important in overall evaluation of radionuclide therapy effectiveness. Clinicians and pharmaceutical companies should recognize the value of a balanced approach to personalized internal dosimetry for maximizing therapy benefit while minimizing toxicity. Prospective clinical trials should employ quantitative dosimetry with standardized methodologies to deliver predictive paradigms and establish the efficacy of new radioimmunotherapy products.
Collapse
Affiliation(s)
- Darrell R Fisher
- Washington State University and Versant Medical Physics and Radiation Safety, Richland, Washington, USA
| |
Collapse
|
6
|
Abstract
Radiopharmaceutical therapy (RPT) involves the use of radionuclides that are either conjugated to tumor-targeting agents (e.g., nanoscale constructs, antibodies, peptides, and small molecules) or concentrated in tissue through natural physiological mechanisms that occur predominantly in neoplastic or otherwise targeted cells (e.g., Graves disease). The ability to collect pharmacokinetic data by imaging and use this to perform dosimetry calculations for treatment planning distinguishes RPT from other systemic treatment modalities such as chemotherapy, wherein imaging is not generally used. Treatment planning has not been widely adopted, in part, because early attempts to relate dosimetry to outcome were not successful. This was partially because a dosimetry methodology appropriate to risk evaluation rather than efficacy and toxicity was being applied to RPT. The weakest links in both diagnostic and therapeutic dosimetry are the accuracy of the input and the reliability of the radiobiological models used to convert dosimetric data to the relevant biologic end points. Dosimetry for RPT places a greater demand on both of these weak links. To date, most dosimetric studies have been retrospective, with a focus on tumor dose-response correlations rather than prospective treatment planning. In this regard, transarterial radioembolization also known as intra-arterial radiation therapy, which uses radiolabeled ((90)Y) microspheres of glass or resin to treat lesions in the liver holds much promise for more widespread dosimetric treatment planning. The recent interest in RPT with alpha-particle emitters has highlighted the need to adopt a dosimetry methodology that specifically accounts for the unique aspects of alpha particles. The short range of alpha-particle emitters means that in cases in which the distribution of activity is localized to specific functional components or cell types of an organ, the absorbed dose will be equally localized and dosimetric calculations on the scale of organs or even voxels (~5mm) are no longer sufficient. This limitation may be overcome by using preclinical models to implement macromodeling to micromodeling. In contrast to chemotherapy, RPT offers the possibility of evaluating radiopharmaceutical distributions, calculating tumor and normal tissue absorbed doses, and devising a treatment plan that is optimal for a specific patient or specific group of patients.
Collapse
|
7
|
Cicone F, D'Arienzo M, Carpaneto A, Russo E, Coniglio A, Delaloye AB, Scopinaro F. Quantification of dose nonuniformities by voxel-based dosimetry in patients receiving 90Y-ibritumomab-tiuxetan. Cancer Biother Radiopharm 2013; 28:98-107. [PMID: 23289952 DOI: 10.1089/cbr.2012.1299] [Citation(s) in RCA: 7] [Impact Index Per Article: 0.6] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/12/2022] Open
Abstract
UNLABELLED Abstract Objective: To assess the impact of nonuniform dose distribution within lesions and tumor-involved organs of patients receiving Zevalin(®), and to discuss possible implications of equivalent uniform biological effective doses (EU-BED) on treatment efficacy and toxicity. MATLAB™ -based software for voxel-based dosimetry was adopted for this purpose. METHODS Eleven lesions from seven patients with either indolent or aggressive non-Hodgkin lymphoma were analyzed, along with four organs with disease. Absorbed doses were estimated by a direct integration of single-voxel kinetic data from serial tomographic images. After proper corrections, differential BED distributions and surviving cell fractions were estimated, allowing for the calculation of EU-BED. To quantify dose uniformity in each target area, a heterogeneity index was defined. RESULTS Average doses were below those prescribed by conventional radiotherapy to eradicate lymphoma lesions. Dose heterogeneity and effect on tumor control varied among lesions, with no apparent relation to tumor mass. Although radiation doses to involved organs were safe, unexpected liver toxicity occurred in one patient who presented with a pattern of diffuse infiltration. CONCLUSION Voxel-based dosimetry and radiobiologic modeling can be successfully applied to lesions and tumor-involved organs, representing a methodological advance over estimation of mean absorbed doses. However, effects on tumor control and organ toxicity still cannot be easily predicted.
Collapse
Affiliation(s)
- Francesco Cicone
- Nuclear Medicine, Department of Translational Medicine, Faculty of Medicine and Psychology, Sant'Andrea Hospital, Sapienza University of Rome, Rome, Italy.
| | | | | | | | | | | | | |
Collapse
|
8
|
D'Arienzo M, Cicone F, Chiacchiararelli L, Coniglio A, Delaloye AB, Scopinaro F. Three-Dimensional Patient-Specific Dosimetry in Radioimmunotherapy with 90Y-Ibritumomab-Tiuxetan. Cancer Biother Radiopharm 2012; 27:124-33. [DOI: 10.1089/cbr.2011.1063] [Citation(s) in RCA: 4] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/13/2023] Open
Affiliation(s)
- Marco D'Arienzo
- Medical Physics, Sant'Andrea Hospital, Rome, Italy
- Istituto Nazionale di Metrologia delle Radiazioni Ionizzanti, ENEA, Centro Ricerche Casaccia, Rome, Italy
| | - Francesco Cicone
- Nuclear Medicine, Sant'Andrea Hospital, Department of Translational Medicine, Faculty of Medicine and Psychology, “Sapienza” University of Rome, Rome, Italy
| | | | - Angela Coniglio
- Medical Physics, San Giovanni Calibita Hospital - Fatebenefratelli, Isola Tiberina, Rome, Italy
| | - Angelika Bischof Delaloye
- Nuclear Medicine, Centre Hospitalier Universitaire Vaudois and University of Lausanne, Lausanne, Switzerland
| | - Francesco Scopinaro
- Nuclear Medicine, Sant'Andrea Hospital, Department of Translational Medicine, Faculty of Medicine and Psychology, “Sapienza” University of Rome, Rome, Italy
| |
Collapse
|
9
|
Abstract
Conventional external-beam radiation therapy is dedicated to the treatment of localized disease, whereas radioimmunotherapy represents an innovative tool for the treatment of local or diffuse tumors. Radioimmunotherapy involves the administration of radiolabeled monoclonal antibodies that are directed specifically against tumor-associated antigens or against the tumor microenvironment. Although many tumor-associated antigens have been identified as possible targets for radioimmunotherapy of patients with hematological or solid tumors, clinical success has so far been achieved mostly with radiolabeled antibodies against CD20 ((131)I-tositumomab and (90)Y-ibritumomab tiuxetan) for the treatment of lymphoma. In this Review, we provide an update on the current challenges aimed to improve the efficacy of radioimmunotherapy and discuss the main radiobiological issues associated with clinical radioimmunotherapy.
Collapse
|
10
|
Pacilio M, Basile C, Shcherbinin S, Caselli F, Ventroni G, Aragno D, Mango L, Santini E. An innovative iterative thresholding algorithm for tumour segmentation and volumetric quantification on SPECT images: Monte Carlo-based methodology and validation. Med Phys 2011; 38:3050-61. [PMID: 21815378 DOI: 10.1118/1.3590359] [Citation(s) in RCA: 13] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/15/2022] Open
Abstract
PURPOSE Positron emission tomography (PET) and single-photon emission computed tomography (SPECT) imaging play an important role in the segmentation of functioning parts of organs or tumours, but an accurate and reproducible delineation is still a challenging task. In this work, an innovative iterative thresholding method for tumour segmentation has been proposed and implemented for a SPECT system. This method, which is based on experimental threshold-volume calibrations, implements also the recovery coefficients (RC) of the imaging system, so it has been called recovering iterative thresholding method (RIThM). The possibility to employ Monte Carlo (MC) simulations for system calibration was also investigated. METHODS The RIThM is an iterative algorithm coded using MATLAB: after an initial rough estimate of the volume of interest, the following calculations are repeated: (i) the corresponding source-to-background ratio (SBR) is measured and corrected by means of the RC curve; (ii) the threshold corresponding to the amended SBR value and the volume estimate is then found using threshold-volume data; (iii) new volume estimate is obtained by image thresholding. The process goes on until convergence. The RIThM was implemented for an Infinia Hawkeye 4 (GE Healthcare) SPECT/CT system, using a Jaszczak phantom and several test objects. Two MC codes were tested to simulate the calibration images: SIMIND and SimSet. For validation, test images consisting of hot spheres and some anatomical structures of the Zubal head phantom were simulated with SIMIND code. Additional test objects (flasks and vials) were also imaged experimentally. Finally, the RIThM was applied to evaluate three cases of brain metastases and two cases of high grade gliomas. RESULTS Comparing experimental thresholds and those obtained by MC simulations, a maximum difference of about 4% was found, within the errors (+/- 2% and +/- 5%, for volumes > or = 5 ml or < 5 ml, respectively). Also for the RC data, the comparison showed differences (up to 8%) within the assigned error (+/- 6%). ANOVA test demonstrated that the calibration results (in terms of thresholds or RCs at various volumes) obtained by MC simulations were indistinguishable from those obtained experimentally. The accuracy in volume determination for the simulated hot spheres was between -9% and 15% in the range 4-270 ml, whereas for volumes less than 4 ml (in the range 1-3 ml) the difference increased abruptly reaching values greater than 100%. For the Zubal head phantom, errors ranged between 9% and 18%. For the experimental test images, the accuracy level was within +/- 10%, for volumes in the range 20-110 ml. The preliminary test of application on patients evidenced the suitability of the method in a clinical setting. CONCLUSIONS The MC-guided delineation of tumor volume may reduce the acquisition time required for the experimental calibration. Analysis of images of several simulated and experimental test objects, Zubal head phantom and clinical cases demonstrated the robustness, suitability, accuracy, and speed of the proposed method. Nevertheless, studies concerning tumors of irregular shape and/or nonuniform distribution of the background activity are still in progress.
Collapse
Affiliation(s)
- M Pacilio
- Department of Medical Physics, Azienda Ospedaliera S. Camillo Forlanini, Rome 00151, Italy.
| | | | | | | | | | | | | | | |
Collapse
|
11
|
Grudzinski JJ, Tomé W, Weichert JP, Jeraj R. The biological effectiveness of targeted radionuclide therapy based on a whole-body pharmacokinetic model. Phys Med Biol 2010; 55:5723-34. [PMID: 20826898 DOI: 10.1088/0031-9155/55/19/007] [Citation(s) in RCA: 5] [Impact Index Per Article: 0.4] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/11/2022]
Abstract
Biologically effective dose (BED) may be more of a relevant quantity than absorbed dose for establishing tumour response relationships. By taking into account the dose rate and tissue-specific parameters such as repair and radiosensitivity, it is possible to compare the relative biological effects of different targeted radionuclide therapy (TRT) agents. The aim of this work was to develop an analytical tumour BED calculation for TRT that could predict a relative biological effect based on normal body and tumour pharmacokinetics. This work represents a step in the direction of establishing relative pharmacokinetic criteria of when the BED formalism is more applicable than absorbed dose for TRT. A previously established pharmacokinetic (PK) model for TRT was used and adapted into the BED formalism. An analytical equation for the protraction factor, which incorporates dose rate and repair rate, was derived. Dose rates within the normal body and tumour were related to the slopes of their time-activity curves which were determined by the ratios of their respective PK parameters. The relationships between the tumour influx-to-efflux ratio (k(34):k(43)), central compartment efflux-to-influx ratio (k(12):k(21)), central elimination (k(el)), and tumour repair rate (μ), and tumour BED were investigated. As the k(34):k(43) ratio increases and the k(12):k(21) ratio decreases, the difference between tumour BED and D increases. In contrast, as the k(34):k(43) ratios decrease and the k(12):k(21) ratios increase, the tumour BED approaches D. At large k(34):k(43) ratios, the difference between tumour BED and D increases to a maximum as k(el) increases. At small k(34):k(43) ratios, the tumour BED approaches D at very small k(el). At small μ and small k(34):k(43) ratios, the tumour BED approaches D. For large k(34):k(43) ratios, large μ values cause tumour BED to approach D. This work represents a step in the direction of establishing relative PK criteria of when the BED formalism is more applicable than absorbed dose for TRT. It also provides a framework by which the biological effects of different TRT agents can be compared in order to predict efficacy.
Collapse
Affiliation(s)
- Joseph J Grudzinski
- Department of Medical Physics, University of Wisconsin School of Medicine and Public Health, 1111 Highland Ave, Madison, WI 53705, USA.
| | | | | | | |
Collapse
|