Performance evaluation of a preclinical SPECT/CT system for multi-animal and multi-isotope quantitative experiments. Sci Rep 2022; 12:18161. [PMID: 36307420 PMCID: PMC9616809 DOI: 10.1038/s41598-022-21687-2] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/02/2022] [Accepted: 09/30/2022] [Indexed: 12/31/2022] Open
Abstract
The aim was to study the performance of the U-SPECT6/CT E-class system for preclinical imaging, to later demonstrate the viability of simultaneous multi-animal and multi-isotope imaging with reliable quantitative accuracy. The performance of the SPECT was evaluated for two collimators dedicated for mouse (UHS-M) and rat imaging (UHR-RM) in terms of sensitivity, energy resolution, uniformity and spatial resolution. Point sources, hot‑rod and uniform phantoms were scanned, and additional tests were carried out to evaluate singular settings such as simultaneous multi-isotope acquisition and imaging with a multi-bed system. For in-vivo evaluation, simultaneous triple-isotope and multi-animal studies were performed on mice. Sensitivity for 99mTc was 2370 cps/MBq for the UHS-M collimator and 493 cps/MBq for the UHR-RM. Rods of 0.6 mm and 0.9 mm were discernible with the UHS-M and UHR-RM collimators respectively, with optimized reconstruction. Uniformity in low counting conditions has proven to be poor (> 75%). Multi-isotope and multi-bed phantom acquisitions demonstrated accurate quantification. In mice, simultaneous multi-isotope imaging provided the separate distribution of 3 tracers and image quality of the multi-mouse bone scan was adequate. The U-SPECT6/CT E-class has shown good sensitivity and spatial resolution. This system provides quantitative images with suitable image quality for multi-mouse and multi-isotope acquisitions.
Collapse
|
2
|
Dexter K, Foster J, Sosabowski J, Petrik M. Preclinical PET and SPECT Instrumentation. Nucl Med Mol Imaging 2022. [DOI: 10.1016/b978-0-12-822960-6.00055-7] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/28/2022] Open
|
3
|
Hoffmann JV, Janssen JP, Kanno T, Shibutani T, Onoguchi M, Lapa C, Grunz JP, Buck AK, Higuchi T. Performance evaluation of fifth-generation ultra-high-resolution SPECT system with two stationary detectors and multi-pinhole imaging. EJNMMI Phys 2020; 7:64. [PMID: 33140263 PMCID: PMC7606439 DOI: 10.1186/s40658-020-00335-6] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.6] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/14/2020] [Accepted: 10/19/2020] [Indexed: 11/12/2022] Open
Abstract
Background Small-animal single-photon emission computed tomography (SPECT) systems with multi-pinhole collimation and large stationary detectors have advantages compared to systems with moving small detectors. These systems benefit from less labour-intensive maintenance and quality control as fewer prone parts are moving, higher accuracy for focused scans and maintaining high resolution with increased sensitivity due to focused pinholes on the field of view. This study aims to investigate the performance of a novel ultra-high-resolution scanner with two-detector configuration (U-SPECT5-E) and to compare its image quality to a conventional micro-SPECT system with three stationary detectors (U-SPECT+). Methods The new U-SPECT5-E with two stationary detectors was used for acquiring data with 99mTc-filled point source, hot-rod and uniformity phantoms to analyse sensitivity, spatial resolution, uniformity and contrast-to-noise ratio (CNR). Three dedicated multi-pinhole mouse collimators with 75 pinholes each and 0.25-, 0.60- and 1.00-mm pinholes for extra ultra-high resolution (XUHR-M), general-purpose (GP-M) and ultra-high sensitivity (UHS-M) imaging were examined. For CNR analysis, four different activity ranges representing low- and high-count settings were investigated for all three collimators. The experiments for the performance assessment were repeated with the same GP-M collimator in the three-detector U-SPECT+ for comparison. Results Peak sensitivity was 237 cps/MBq (XUHR-M), 847 cps/MBq (GP-M), 2054 cps/MBq (UHS-M) for U-SPECT5-E and 1710 cps/MBq (GP-M) for U-SPECT+. In the visually analysed sections of the reconstructed mini Derenzo phantoms, rods as small as 0.35 mm (XUHR-M), 0.50 mm (GP-M) for the two-detector as well as the three-detector SPECT and 0.75 mm (UHS-M) were resolved. Uniformity for maximum resolution recorded 40.7% (XUHR-M), 29.1% (GP-M, U-SPECT5-E), 16.3% (GP-M, U-SPECT+) and 23.0% (UHS-M), respectively. UHS-M reached highest CNR values for low-count images; for rods smaller than 0.45 mm, acceptable CNR was only achieved by XUHR-M. GP-M was superior for imaging rods sized from 0.60 to 1.50 mm for intermediate activity concentrations. U-SPECT5-E and U-SPECT+ both provided comparable CNR. Conclusions While uniformity and sensitivity are negatively affected by the absence of a third detector, the investigated U-SPECT5-E system with two stationary detectors delivers excellent spatial resolution and CNR comparable to the performance of an established three-detector-setup.
Collapse
Affiliation(s)
- Jan V Hoffmann
- Department of Nuclear Medicine, University Hospital Würzburg, Oberdürrbacher Strasse 6, 97080, Würzburg, Germany.,Comprehensive Heart Failure Center, University Hospital Würzburg, Würzburg, Germany
| | - Jan P Janssen
- Department of Nuclear Medicine, University Hospital Würzburg, Oberdürrbacher Strasse 6, 97080, Würzburg, Germany.,Comprehensive Heart Failure Center, University Hospital Würzburg, Würzburg, Germany
| | - Takayuki Kanno
- Comprehensive Heart Failure Center, University Hospital Würzburg, Würzburg, Germany.,Department of Quantum Medical Technology, Graduate School of Medical Sciences, Kanazawa University, Kanazawa, Japan
| | - Takayuki Shibutani
- Department of Quantum Medical Technology, Graduate School of Medical Sciences, Kanazawa University, Kanazawa, Japan
| | - Masahisa Onoguchi
- Department of Quantum Medical Technology, Graduate School of Medical Sciences, Kanazawa University, Kanazawa, Japan
| | - Constantin Lapa
- Nuclear Medicine, Medical Faculty, University of Augsburg, Augsburg, Germany
| | - Jan-Peter Grunz
- Department of Diagnostic and Interventional Radiology, University Hospital Würzburg, Würzburg, Germany
| | - Andreas K Buck
- Department of Nuclear Medicine, University Hospital Würzburg, Oberdürrbacher Strasse 6, 97080, Würzburg, Germany
| | - Takahiro Higuchi
- Department of Nuclear Medicine, University Hospital Würzburg, Oberdürrbacher Strasse 6, 97080, Würzburg, Germany. .,Comprehensive Heart Failure Center, University Hospital Würzburg, Würzburg, Germany. .,Graduate School of Medicine, Dentistry and Pharmaceutical Sciences, Okayama University, Okayama, Japan.
| |
Collapse
|
4
|
Wang B, van Roosmalen J, Kreuger R, Huizenga J, Beekman FJ, Goorden MC. Characterization of a multi-pinhole molecular breast tomosynthesis scanner. Phys Med Biol 2020; 65:195010. [PMID: 32570222 DOI: 10.1088/1361-6560/ab9eff] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.4] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/29/2022]
Abstract
In recent years, breast imaging using radiolabelled molecules has attracted significant interest. Our group has proposed a multi-pinhole molecular breast tomosynthesis (MP-MBT) scanner to obtain 3D functional molecular breast images at high resolutions. After conducting extensive optimisation studies using simulations, we here present a first prototype of MP-MBT and evaluate its performance using physical phantoms. The MP-MBT design is based on two opposing gamma cameras that can image a lightly compressed pendant breast. Each gamma camera consists of a 250 × 150 mm2 detector equipped with a collimator with multiple pinholes focusing on a line. The NaI(Tl) gamma detector is a customised design with 3.5 mm intrinsic spatial resolution and high spatial linearity near the edges due to a novel light-guide geometry and the use of square PMTs. A volume-of-interest is scanned by translating the collimator and gamma detector together in a sequence that optimises count yield from the scan region. Derenzo phantom images showed that the system can reach 3.5 mm resolution for a clinically realistic 99mTc activity concentration in an 11-minute scan, while in breast phantoms the smallest spheres visible were 6 mm in diameter for the same scan time. To conclude, the experimental results of the novel MP-MBT scanner showed that the setup had sub-centimetre breast tumour detection capability which might facilitate 3D molecular breast cancer imaging in the future.
Collapse
Affiliation(s)
- Beien Wang
- Section of Biomedical Imaging, Department of Radiation Science and Technology, Delft University of Technology, Mekelweg 15 2629 JB, Delft, The Netherlands
| | | | | | | | | | | |
Collapse
|
5
|
Ozsahin I, Chen L, Könik A, King MA, Beekman FJ, Mok GSP. The clinical utilities of multi-pinhole single photon emission computed tomography. Quant Imaging Med Surg 2020; 10:2006-2029. [PMID: 33014732 PMCID: PMC7495312 DOI: 10.21037/qims-19-1036] [Citation(s) in RCA: 16] [Impact Index Per Article: 3.2] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/08/2020] [Accepted: 07/30/2020] [Indexed: 11/06/2022]
Abstract
Single photon emission computed tomography (SPECT) is an important imaging modality for various applications in nuclear medicine. The use of multi-pinhole (MPH) collimators can provide superior resolution-sensitivity trade-off when imaging small field-of-view compared to conventional parallel-hole and fan-beam collimators. Besides the very successful application in small animal imaging, there has been a resurgence of the use of MPH collimators for clinical cardiac and brain studies, as well as other small field-of-view applications. This article reviews the basic principles of MPH collimators and introduces currently available and proposed clinical MPH SPECT systems.
Collapse
Affiliation(s)
- Ilker Ozsahin
- Biomedical Imaging Laboratory, Department of Electrical and Computer Engineering, Faculty of Science and Technology, University of Macau, Macau, China
- Department of Biomedical Engineering, Faculty of Engineering, Near East University, Nicosia/TRNC, Mersin-10, Turkey
- DESAM Institute, Near East University, Nicosia/TRNC, Mersin-10, Turkey
| | - Ling Chen
- Biomedical Imaging Laboratory, Department of Electrical and Computer Engineering, Faculty of Science and Technology, University of Macau, Macau, China
| | - Arda Könik
- Department of Imaging, Dana Farber Cancer Institute, Boston, MA, USA
| | - Michael A. King
- Department of Radiology, University of Massachusetts Medical School, Worcester, MA, USA
| | - Freek J. Beekman
- Section of Biomedical Imaging, Department of Radiation Science and Technology, Delft University of Technology, Mekelweg 15, 2629 JB Delft, The Netherlands
- MILabs B.V, Heidelberglaan 100, 3584 CX, Utrecht, The Netherlands
- Department of Translational Neuroscience, Brain Center Rudolf Magnus, University Medical Center Utrecht, The Netherlands
| | - Greta S. P. Mok
- Biomedical Imaging Laboratory, Department of Electrical and Computer Engineering, Faculty of Science and Technology, University of Macau, Macau, China
- Center for Cognitive and Brain Sciences, Institute of Collaborative Innovation, University of Macau, Macau, China
| |
Collapse
|
6
|
Moktan H, Ahmed MF, Jayarathna S, Deng L, Cho SH. Monte Carlo study of x-ray detection configurations for benchtop x-ray fluorescence computed tomography of gold nanoparticle-loaded objects. Phys Med Biol 2020; 65:175010. [PMID: 32869750 DOI: 10.1088/1361-6560/ab9774] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.2] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/01/2023]
Abstract
Over the last decade, the performance of benchtop x-ray fluorescence computed tomography (XFCT) systems has been significantly enhanced through hardware and software optimizations. Recent studies have indicated the need of energy-resolving pixelated/array detectors in the x-ray detection component to further improve the sensitivity and image resolution of benchtop XFCT systems while meeting the realistic constraints of dose and scan time. Thus, it is of immediate interest in the research community to conduct the following investigations: (a) delineation of strengths/weaknesses of detection configurations that incorporate pixelated/array detectors in combination with two most frequently used (parallel-hole and pinhole) collimators; (b) one-to-one comparison of their performance under identical imaging conditions of benchtop XFCT. In this study, we developed a Geant4-based Monte Carlo model to investigate the effects of the aforementioned detection configurations on the sensitivity and image resolution of a benchtop XFCT system. Using this model, we simulated the detection of x-ray fluorescence and scattered photons from gold nanoparticle-containing phantoms using energy-resolving pixelated detectors coupled with parallel-hole and pinhole collimators. Simulation results demonstrated that the detector consisting of large pixels (1 mm × 1 mm) combined with a parallel-hole collimator had better sensitivity (i.e. lower detection limit) than the detector made of smaller pixels (0.25 mm × 0.25 mm) coupled with a pinhole collimator. In comparison, although slightly less sensitive, the latter detector configuration achieved better image resolution than did the former. Thus, a detection configuration consisting of a pixelated detector with submillimeter pixels and a pinhole collimator is preferable when image resolution is critical for benchtop XFCT applications. On the other hand, the detector with larger pixels coupled with a parallel-hole collimator is better suited for benchtop XFCT applications in which higher sensitivity and shorter scan time are essential.
Collapse
Affiliation(s)
- Hem Moktan
- Department of Radiation Physics, The University of Texas MD Anderson Cancer Center, Houston, TX 77030, United States of America
| | | | | | | | | |
Collapse
|
7
|
Nguyen MP, Ramakers RM, Kamphuis C, Koustoulidou S, Goorden MC, Beekman FJ. EXIRAD-3D: Fast automated three-dimensional autoradiography. Nucl Med Biol 2020; 86-87:59-65. [DOI: 10.1016/j.nucmedbio.2020.06.001] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.6] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/21/2020] [Revised: 05/15/2020] [Accepted: 06/02/2020] [Indexed: 12/12/2022]
|
8
|
Goorden MC, Kamphuis C, Ramakers RM, Beekman FJ. Accelerated image reconstruction by a combined dual-matrix dual-voxel approach. ACTA ACUST UNITED AC 2020; 65:105014. [DOI: 10.1088/1361-6560/ab82e9] [Citation(s) in RCA: 5] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/11/2022]
|
9
|
Chen Y, Goorden MC, Vastenhouw B, Beekman FJ. Optimized sampling for high resolution multi-pinhole brain SPECT with stationary detectors. ACTA ACUST UNITED AC 2020; 65:015002. [DOI: 10.1088/1361-6560/ab5bc6] [Citation(s) in RCA: 5] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/20/2022]
|
10
|
Naseri M, Rajabi H, Wang J, Abbasi M, Kalantari F. Simultaneous respiratory motion correction and image reconstruction in 4D-multi pinhole small animal SPECT. Med Phys 2019; 46:5047-5054. [PMID: 31495940 DOI: 10.1002/mp.13807] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.2] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/09/2019] [Revised: 08/22/2019] [Accepted: 08/22/2019] [Indexed: 11/05/2022] Open
Abstract
PURPOSE Respiratory motion in the chest region during single photon emission computed tomography (SPECT) is a major degrading factor that reduces the accuracy of image quantification. This effect is more notable when the tumor is very small, or the spatial resolution of the imaging system is less than the respiratory motion amplitude. Small animals imaging systems with sub-millimeter spatial resolution need more attention to the respiratory motion for quantitative studies. We developed a motion-embedded four-dimensional (4D)-multi pinhole SPECT (MPS) reconstruction algorithm for respiratory motion correction. This algorithm makes full use of projection statistics for reconstruction of every individual frame. METHODS The ROBY phantom with small tumors in liver was generated in eight different phases during one respiratory cycle. The MPS projections were modeled using a fast ray tracing method simulating an MPS acquisition. Individual frames were reconstructed and used for motion estimation. The Demons non-rigid registration algorithm was used to calculate deformation vector fields (DVFs) for simultaneous motion correction and image reconstruction. A motion-embedded 4D-MPS method was used to reconstruct images using all the projections and corresponding DVFs, simultaneously. The 4D-MPS reconstructed images were compared to the low-count single frame (LCSF) reconstructed image, the three-dimensional (3D)-MPS images reconstructed using individual frames, and post reconstruction registration (PRR) that aligns all individual phases to a reference frame using Demons-derived DVFs. The tumor volume relative error (TVE), tumor contrast relative error (TCE), and dice index (DI) for 2, 3, and 4 mm liver were calculated and compared for different reconstruction methods. RESULTS For the 4D-MPS reconstruction method, TVE was reduced and DI was higher compared to PRR, 3D-MPS, and LCSF. The extent of the improvement was higher for the small tumor size (i.e. 2 mm). For the biggest tumor in contrast 3 (i.e. 4 mm) TVE for 4D-MPS, PRR, 3D-MPS and, LCSF were 1.33%, 8%, 8%, and 14.67%, respectively. CONCLUSIONS The results suggest that motion-embedded 4D-MPS method is an effective and practical way for respiratory motion correction. It reconstructs high quality gated frames while using all projection data to reconstruct each frame.
Collapse
Affiliation(s)
- Maryam Naseri
- Medical Physics Program, Department of Physics and Astronomy, Louisiana State University, Baton Rouge, LA, USA.,Department of Medical Physics, Faculty of Medicine, Tarbiat Modares University, Tehran, Iran
| | - Hossein Rajabi
- Department of Medical Physics, Faculty of Medicine, Tarbiat Modares University, Tehran, Iran
| | - Jing Wang
- Department of Radiation Oncology, UT Southwestern Medical Center Dallas, Dallas, TX, USA
| | - Mehrshad Abbasi
- Department of Nuclear Medicine, Vali-Asr Hospital, Tehran University of Medical Sciences, Tehran, Iran
| | - Faraz Kalantari
- Department of Radiation Oncology, University of Arkansas for Medical Sciences, Little Rock, AR, USA
| |
Collapse
|
11
|
Jiang J, Li K, Wang Q, Puterbaugh K, Young JW, Siegel SB, O'Sullivan JA, Tai YC. A second-generation virtual-pinhole PET device for enhancing contrast recovery and improving lesion detectability of a whole-body PET/CT scanner. Med Phys 2019; 46:4165-4176. [PMID: 31315157 DOI: 10.1002/mp.13724] [Citation(s) in RCA: 7] [Impact Index Per Article: 1.2] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/26/2019] [Revised: 07/10/2019] [Accepted: 07/11/2019] [Indexed: 02/03/2023] Open
Abstract
PURPOSE We have developed a second-generation virtual-pinhole (VP) positron emission tomography (PET) device that can position a flat-panel PET detector around a patient's body using a robotic arm to enhance the contrast recovery coefficient (CRC) and detectability of lesions in any region-of-interest using a whole-body PET/computed tomography (CT) scanner. METHODS We constructed a flat-panel VP-PET device using 32 high-resolution detectors, each containing a 4 × 4 MPPC array and 16 × 16 LYSO crystals of 1.0 × 1.0 × 3.0 mm3 each. The flat-panel detectors can be positioned around a patient's body anywhere in the imaging field-of-view (FOV) of a Siemens Biograph 40 PET/CT scanner by a robotic arm. New hardware, firmware and software have been developed to support the additional detector signals without compromising a scanner's native functions. We stepped a 22 Na point source across the axial FOV of the scanner to measure the sensitivity profile of the VP-PET device. We also recorded the coincidence events measured by the scanner detectors and by the VP-PET detectors when imaging phantoms of different sizes. To assess the improvement in the CRC of small lesions, we imaged an elliptical torso phantom measuring 316 × 228 × 162 mm3 that contains spherical tumors with diameters ranging from 3.3 to 11.4 mm with and without the VP-PET device. Images were reconstructed using a list mode Maximum-Likelihood Estimation-Maximization algorithm implemented on multiple graphics processing units (GPUs) to support the unconventional geometries enabled by a VP-PET system. The mean and standard deviation of the CRC were calculated for tumors of different sizes. Monte Carlo simulation was also conducted to image clusters of lesions in a torso phantom using a PET/CT scanner alone or the same scanner equipped with VP-PET devices. Receiver operating characteristic (ROC) curves were analyzed for three system configurations to evaluate the improvement in lesion detectability by the VP-PET device over the native PET/CT scanner. RESULTS The repeatability in positioning the flat-panel detectors using a robotic arm is better than 0.15 mm in all three directions. Experimental results show that the average CRC of 3.3, 4.3, and 6.0 mm diameter tumors was 0.82%, 2.90%, and 5.25%, respectively, when measured by the native scanner. The corresponding CRC was 2.73%, 6.21% and 10.13% when imaged by the VP-PET insert device with the flat-panel detector under the torso phantom. These values may be further improved to 4.31%, 9.65% and 18.01% by a future dual-panel VP-PET insert device if DOI detectors are employed to triple its detector efficiency. Monte Carlo simulation results show that the tumor detectability can be improved by a VP-PET device that has a single flat-panel detector. The improvement is greater if the VP-PET device employs a dual-panel design. CONCLUSIONS We have developed a prototype flat-panel VP-PET device and integrated it with a clinical PET/CT scanner. It significantly enhances the contrast of lesions, especially for those that are borderline detectable by the native scanner, within regions-of-interest specified by users. Simulation demonstrated the enhancement in lesion detectability with the VP-PET device. This technology may become a cost-effective solution for organ-specific imaging tasks.
Collapse
Affiliation(s)
- Jianyong Jiang
- Mallinckrodt Institute of Radiology, Washington University in St. Louis, St. Louis, MO, 63110, USA
| | - Ke Li
- Department of Electrical and Systems Engineering, Washington University in St. Louis, St. Louis, MO, 63130, USA
| | - Qiang Wang
- Mallinckrodt Institute of Radiology, Washington University in St. Louis, St. Louis, MO, 63110, USA
| | - Kenneth Puterbaugh
- Molecular Imaging, Siemens Medical Solutions USA, Inc, Knoxville, TN, 37932, USA
| | - John W Young
- Molecular Imaging, Siemens Medical Solutions USA, Inc, Knoxville, TN, 37932, USA
| | - Stefan B Siegel
- Molecular Imaging, Siemens Medical Solutions USA, Inc, Knoxville, TN, 37932, USA
| | - Joseph A O'Sullivan
- Department of Electrical and Systems Engineering, Washington University in St. Louis, St. Louis, MO, 63130, USA
| | - Yuan-Chuan Tai
- Mallinckrodt Institute of Radiology, Washington University in St. Louis, St. Louis, MO, 63110, USA
| |
Collapse
|
12
|
Meester EJ, Krenning BJ, de Swart J, Segbers M, Barrett HE, Bernsen MR, Van der Heiden K, de Jong M. Perspectives on Small Animal Radionuclide Imaging; Considerations and Advances in Atherosclerosis. Front Med (Lausanne) 2019; 6:39. [PMID: 30915335 PMCID: PMC6421263 DOI: 10.3389/fmed.2019.00039] [Citation(s) in RCA: 11] [Impact Index Per Article: 1.8] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/21/2018] [Accepted: 02/11/2019] [Indexed: 12/20/2022] Open
Abstract
This review addresses nuclear SPECT and PET imaging in small animals in relation to the atherosclerotic disease process, one of our research topics of interest. Imaging of atherosclerosis in small animal models is challenging, as it operates at the limits of current imaging possibilities regarding sensitivity, and spatial resolution. Several topics are discussed, including technical considerations that apply to image acquisition, reconstruction, and analysis. Moreover, molecules developed for or applied in these small animal nuclear imaging studies are listed, including target-directed molecules, useful for imaging organs or tissues that have elevated expression of the target compared to other tissues, and molecules that serve as substrates for metabolic processes. Differences between animal models and human pathophysiology that should be taken into account during translation from animal to patient as well as differences in tracer behavior in animal vs. man are also described. Finally, we give a future outlook on small animal radionuclide imaging in atherosclerosis, followed by recommendations. The challenges and solutions described might be applicable to other research fields of health and disease as well.
Collapse
Affiliation(s)
- Eric J Meester
- Department of Radiology and Nuclear Medicine, Erasmus Medical Center, Rotterdam, Netherlands.,Department of Biomedical Engineering, Thorax Center, Erasmus Medical Center, Rotterdam, Netherlands
| | - B J Krenning
- Department of Cardiology, Thorax Center, Erasmus Medical Center, Rotterdam, Netherlands
| | - J de Swart
- Department of Radiology and Nuclear Medicine, Erasmus Medical Center, Rotterdam, Netherlands
| | - M Segbers
- Department of Radiology and Nuclear Medicine, Erasmus Medical Center, Rotterdam, Netherlands
| | - H E Barrett
- Department of Radiology and Nuclear Medicine, Erasmus Medical Center, Rotterdam, Netherlands.,Department of Biomedical Engineering, Thorax Center, Erasmus Medical Center, Rotterdam, Netherlands
| | - M R Bernsen
- Department of Radiology and Nuclear Medicine, Erasmus Medical Center, Rotterdam, Netherlands
| | - K Van der Heiden
- Department of Biomedical Engineering, Thorax Center, Erasmus Medical Center, Rotterdam, Netherlands
| | - Marion de Jong
- Department of Radiology and Nuclear Medicine, Erasmus Medical Center, Rotterdam, Netherlands
| |
Collapse
|
13
|
Chen Y, Vastenhouw B, Wu C, Goorden MC, Beekman FJ. Optimized image acquisition for dopamine transporter imaging with ultra-high resolution clinical pinhole SPECT. ACTA ACUST UNITED AC 2018; 63:225002. [DOI: 10.1088/1361-6560/aae76c] [Citation(s) in RCA: 16] [Impact Index Per Article: 2.3] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 02/04/2023]
|
14
|
van Roosmalen J, Beekman FJ, Goorden MC. System geometry optimization for molecular breast tomosynthesis with focusing multi-pinhole collimators. Phys Med Biol 2017; 63:015018. [PMID: 28994663 DOI: 10.1088/1361-6560/aa9265] [Citation(s) in RCA: 4] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/12/2022]
Abstract
Imaging of 99mTc-labelled tracers is gaining popularity for detecting breast tumours. Recently, we proposed a novel design for molecular breast tomosynthesis (MBT) based on two sliding focusing multi-pinhole collimators that scan a modestly compressed breast. Simulation studies indicate that MBT has the potential to improve the tumour-to-background contrast-to-noise ratio significantly over state-of-the-art planar molecular breast imaging. The aim of the present paper is to optimize the collimator-detector geometry of MBT. Using analytical models, we first optimized sensitivity at different fixed system resolutions (ranging from 5 to 12 mm) by tuning the pinhole diameters and the distance between breast and detector for a whole series of automatically generated multi-pinhole designs. We evaluated both MBT with a conventional continuous crystal detector with 3.2 mm intrinsic resolution and with a pixelated detector with 1.6 mm pixels. Subsequently, full system simulations of a breast phantom containing several lesions were performed for the optimized geometry at each system resolution for both types of detector. From these simulations, we found that tumour-to-background contrast-to-noise ratio was highest for systems in the 7 mm-10 mm system resolution range over which it hardly varied. No significant differences between the two detector types were found.
Collapse
Affiliation(s)
- Jarno van Roosmalen
- Section Biomedical Imaging, Delft University of Technology, Delft, Netherlands
| | | | | |
Collapse
|
15
|
Multi-pinhole fluorescent x-ray computed tomography for molecular imaging. Sci Rep 2017; 7:5742. [PMID: 28720758 PMCID: PMC5516015 DOI: 10.1038/s41598-017-05179-2] [Citation(s) in RCA: 22] [Impact Index Per Article: 2.8] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/28/2017] [Accepted: 05/24/2017] [Indexed: 12/20/2022] Open
Abstract
We propose a multi-pinhole fluorescent x-ray computed tomography (mp-FXCT) technique for preclinical molecular imaging that can provide the complete data necessary to produce 3-D tomographic images during anaesthesia. In this method, multiple projections are simultaneously acquired through a multi-pinhole collimator with a 2-D detector and full-field volumetric beam to accelerate the data acquisition process and enhance the signal-to-noise ratios of the projections. We constructed a 15-pinhole mp-FXCT imaging system at beamline ARNE-7A at KEK and performed preliminary experiments to investigate its imaging properties using physical phantoms and a non-radioactive I imaging agent. The mp-FXCT system could detect an I concentration of 0.038 mg/ml, the minimum required for in-vivo imaging, at a spatial resolution of about 0.3 mm during a data acquisition time of 90 min, which is less than the time for which anaesthesia is effective and suggests that preclinical molecular imaging is feasible with mp-FXCT.
Collapse
|
16
|
Sasaya T, Sunaguchi N, Thet-Lwin T, Hyodo K, Zeniya T, Takeda T, Yuasa T. Dual-energy fluorescent x-ray computed tomography system with a pinhole design: Use of K-edge discontinuity for scatter correction. Sci Rep 2017; 7:44143. [PMID: 28272496 PMCID: PMC5341157 DOI: 10.1038/srep44143] [Citation(s) in RCA: 12] [Impact Index Per Article: 1.5] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/01/2016] [Accepted: 02/03/2017] [Indexed: 12/02/2022] Open
Abstract
We propose a pinhole-based fluorescent x-ray computed tomography (p-FXCT) system with a 2-D detector and volumetric beam that can suppress the quality deterioration caused by scatter components. In the corresponding p-FXCT technique, projections are acquired at individual incident energies just above and below the K-edge of the imaged trace element; then, reconstruction is performed based on the two sets of projections using a maximum likelihood expectation maximization algorithm that incorporates the scatter components. We constructed a p-FXCT imaging system and performed a preliminary experiment using a physical phantom and an I imaging agent. The proposed dual-energy p-FXCT improved the contrast-to-noise ratio by a factor of more than 2.5 compared to that attainable using mono-energetic p-FXCT for a 0.3 mg/ml I solution. We also imaged an excised rat's liver infused with a Ba contrast agent to demonstrate the feasibility of imaging a biological sample.
Collapse
Affiliation(s)
- Tenta Sasaya
- Graduate School of Science and Engineering, Yamagata University, Japan
| | - Naoki Sunaguchi
- Graduate School of Science and Technology, Gunma University, Japan
| | - Thet- Thet-Lwin
- School of Allied Health Sciences, Kitasato University, Japan
| | - Kazuyuki Hyodo
- Institute of Materials Structure Science, High Energy Accelerator Organization (KEK), Japan
| | - Tsutomu Zeniya
- Graduate School of Science and Technology, Hirosaki University, Japan
| | - Tohoru Takeda
- School of Allied Health Sciences, Kitasato University, Japan
| | - Tetsuya Yuasa
- Graduate School of Science and Engineering, Yamagata University, Japan
| |
Collapse
|
17
|
Esquinas PL, Rodríguez-Rodríguez C, Carlos De La Vega J, Bokharaei M, Saatchi K, Shirmohammad M, Häfeli UO, Sossi V, Celler A. 188Re image performance assessment using small animal multi-pinhole SPECT/PET/CT system. Phys Med 2017; 33:26-37. [DOI: 10.1016/j.ejmp.2016.11.105] [Citation(s) in RCA: 10] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 08/17/2016] [Revised: 10/10/2016] [Accepted: 11/14/2016] [Indexed: 02/08/2023] Open
|
18
|
Evaluation of Stationary and Semi-stationary Acquisitions from Dual-head Multi-pinhole Collimator for Myocardial Perfusion SPECT. J Med Biol Eng 2016. [DOI: 10.1007/s40846-016-0169-1] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.2] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/20/2022]
|
19
|
van der Have F, Ivashchenko O, Goorden MC, Ramakers RM, Beekman FJ. High-resolution clustered pinhole 131Iodine SPECT imaging in mice. Nucl Med Biol 2016; 43:506-11. [DOI: 10.1016/j.nucmedbio.2016.05.015] [Citation(s) in RCA: 16] [Impact Index Per Article: 1.8] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/05/2016] [Revised: 05/12/2016] [Accepted: 05/28/2016] [Indexed: 11/25/2022]
|
20
|
van Roosmalen J, Goorden MC, Beekman FJ. Molecular breast tomosynthesis with scanning focus multi-pinhole cameras. Phys Med Biol 2016; 61:5508-28. [PMID: 27384301 DOI: 10.1088/0031-9155/61/15/5508] [Citation(s) in RCA: 17] [Impact Index Per Article: 1.9] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/12/2022]
Abstract
Planar molecular breast imaging (MBI) is rapidly gaining in popularity in diagnostic oncology. To add 3D capabilities, we introduce a novel molecular breast tomosynthesis (MBT) scanner concept based on multi-pinhole collimation. In our design, the patient lies prone with the pendant breast lightly compressed between transparent plates. Integrated webcams view the breast through these plates and allow the operator to designate the scan volume (e.g. a whole breast or a suspected region). The breast is then scanned by translating focusing multi-pinhole plates and NaI(Tl) gamma detectors together in a sequence that optimizes count yield from the volume-of-interest. With simulations, we compared MBT with existing planar MBI. In a breast phantom containing different lesions, MBT improved tumour-to-background contrast-to-noise ratio (CNR) over planar MBI by 12% and 111% for 4.0 and 6.0 mm lesions respectively in case of whole breast scanning. For the same lesions, much larger CNR improvements of 92% and 241% over planar MBI were found in a scan that focused on a breast region containing several lesions. MBT resolved 3.0 mm rods in a Derenzo resolution phantom in the transverse plane compared to 2.5 mm rods distinguished by planar MBI. While planar MBI cannot provide depth information, MBT offered 4.0 mm depth resolution. Our simulations indicate that besides offering 3D localization of increased tracer uptake, multi-pinhole MBT can significantly increase tumour-to-background CNR compared to planar MBI. These properties could be promising for better estimating the position, extend and shape of lesions and distinguishing between single and multiple lesions.
Collapse
Affiliation(s)
- Jarno van Roosmalen
- Section Radiation, Detection & Medical Imaging, Delft University of Technology, Delft, The Netherlands
| | | | | |
Collapse
|
21
|
Ivashchenko O, van der Have F, Villena JL, Groen HC, Ramakers RM, Weinans HH, Beekman FJ. Quarter-millimeter-resolution molecular mouse imaging with U-SPECT⁺. Mol Imaging 2015; 13. [PMID: 25429783 DOI: 10.2310/7290.2014.00053] [Citation(s) in RCA: 32] [Impact Index Per Article: 3.2] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/18/2022] Open
Abstract
Limited spatial resolution of preclinical positron emission tomography (PET) and single-photon emission computed tomography (SPECT) has slowed down applications of molecular imaging in small animals. Here we present the latest-generation U-SPECT system (U-SPECT⁺, MILabs, Utrecht, the Netherlands) enabling radionuclide imaging of mice with quarter-millimeter resolution. The system was equipped with the newest high-resolution collimator with 0.25 mm diameter circular pinholes. It was calibrated with technetium-99 m point source measurements from which the system matrix was calculated. Images were reconstructed using pixel-based ordered subset expectation maximization (OSEM). Various phantoms and mouse SPECT scans were acquired. The reconstructed spatial resolution (the smallest visible capillary diameter in a hot-rod resolution phantom) was 0.25 mm. Knee joint images show tiny structures such as the femur epicondyle sulcus, as well as a clear separation between cortical and trabecular bone structures. In addition, time-activity curves of the lumbar spine illustrated that tracer dynamics in tiny tissue amounts could be measured. U-SPECT⁺ allows discrimination between molecular concentrations in adjacent volumes of as small as 0.015 μL, which is significantly better than can be imaged by any existing SPECT or PET system. This increase in the level of detail makes it more and more attractive to replace ex vivo methods and allows monitoring biological processes in tiny parts of organs in vivo.
Collapse
|
22
|
Performance characteristics of a novel clustered multi-pinhole technology for simultaneous high-resolution SPECT/PET. Ann Nucl Med 2015; 29:460-6. [DOI: 10.1007/s12149-015-0966-6] [Citation(s) in RCA: 20] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/18/2015] [Accepted: 03/19/2015] [Indexed: 11/26/2022]
|
23
|
Rotman M, Welling MM, Bunschoten A, de Backer ME, Rip J, Nabuurs RJA, Gaillard PJ, van Buchem MA, van der Maarel SM, van der Weerd L. Enhanced glutathione PEGylated liposomal brain delivery of an anti-amyloid single domain antibody fragment in a mouse model for Alzheimer's disease. J Control Release 2015; 203:40-50. [PMID: 25668771 DOI: 10.1016/j.jconrel.2015.02.012] [Citation(s) in RCA: 100] [Impact Index Per Article: 10.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/16/2014] [Revised: 02/03/2015] [Accepted: 02/05/2015] [Indexed: 01/08/2023]
Abstract
Treatment of neurodegenerative disorders such as Alzheimer's disease is hampered by the blood-brain barrier (BBB). This tight cerebral vascular endothelium regulates selective diffusion and active transport of endogenous molecules and xenobiotics into and out of the brain parenchyma. In this study, glutathione targeted PEGylated (GSH-PEG) liposomes were designed to deliver amyloid-targeting antibody fragments across the BBB into the brain. Two different formulations of GSH-PEG liposomes based on 1,2-dimyristoyl-sn-glycero-3-phosphocholine (DMPC) and egg-yolk phosphatidylcholine (EYPC) were produced. Both formulations encapsulate 15kDa amyloid beta binding llama single domain antibody fragments (VHH-pa2H). To follow the biodistribution of VHH-pa2H rather than the liposome, the antibody fragment was labeled with the radioisotope indium-111. To prolong the shelf life of the construct beyond the limit of radioactive decay, an active-loading method was developed to efficiently radiolabel the antibody fragments after encapsulation into the liposomes, with radiolabeling efficiencies of up to 68% after purification. The radiolabeled liposomes were administered via a single intravenous bolus injection to APPswe/PS1dE9 double transgenic mice, a mouse model of Alzheimer's disease, and their wildtype littermates. Both GSH-PEG DMPC and GSH-PEG EYPC liposomes significantly increased the standard uptake values (SUV) of VHH-pa2H in the blood of the animals compared to free VHH-pa2H. Encapsulation in GSH-PEG EYPC liposomes resulted in the highest increase in SUV in the brains of transgenic animals. Overall, these data provide evidence that GSH-PEG liposomes may be suitable for specific delivery of single domain antibody fragments over the BBB into the brain.
Collapse
Affiliation(s)
- Maarten Rotman
- Department of Human Genetics, Leiden University Medical Center, Leiden, The Netherlands; Department of Radiology (Molecular Imaging Laboratories Leiden & Nuclear Medicine), Leiden University Medical Center, Leiden, The Netherlands
| | - Mick M Welling
- Department of Radiology (Molecular Imaging Laboratories Leiden & Nuclear Medicine), Leiden University Medical Center, Leiden, The Netherlands
| | - Anton Bunschoten
- Department of Radiology (Interventional Molecular Imaging Laboratory), Leiden University Medical Center, Leiden, The Netherlands
| | | | - Jaap Rip
- to-BBB technologies BV, Leiden, The Netherlands
| | - Rob J A Nabuurs
- Department of Radiology (Molecular Imaging Laboratories Leiden & Nuclear Medicine), Leiden University Medical Center, Leiden, The Netherlands
| | | | - Mark A van Buchem
- Department of Radiology (Molecular Imaging Laboratories Leiden & Nuclear Medicine), Leiden University Medical Center, Leiden, The Netherlands
| | | | - Louise van der Weerd
- Department of Human Genetics, Leiden University Medical Center, Leiden, The Netherlands; Department of Radiology (Molecular Imaging Laboratories Leiden & Nuclear Medicine), Leiden University Medical Center, Leiden, The Netherlands.
| |
Collapse
|
24
|
Ivashchenko O, van der Have F, Goorden MC, Ramakers RM, Beekman FJ. Ultra-high-sensitivity submillimeter mouse SPECT. J Nucl Med 2015; 56:470-5. [PMID: 25678487 DOI: 10.2967/jnumed.114.147140] [Citation(s) in RCA: 32] [Impact Index Per Article: 3.2] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/16/2022] Open
Abstract
UNLABELLED SPECT with submegabecquerel amounts of tracer or subsecond time resolution would enable a wide range of new imaging protocols such as screening tracers with initially low yield or labeling efficiency, imaging low receptor densities, or even performing SPECT outside regular radiation laboratories. To this end we developed dedicated ultra-high-sensitivity pinhole SPECT. METHODS A cylindric collimator with 54 focused 2.0-mm-diameter conical pinholes was manufactured and mounted in a stationary small-animal SPECT system. The system matrix for image reconstruction was calculated via a hybrid method based on both (99m)Tc point source measurements and ray-tracing analytic modeling. SPECT images were reconstructed using pixel-based ordered-subsets expectation maximization. Performance was evaluated with phantoms and low-dose bone, dynamic kidney, and cardiac mouse scans. RESULTS The peak sensitivity reached 1.3% (13,080 cps/MBq). The reconstructed spatial resolution (rod visibility in a micro-Jaszczak phantom) was 0.85 mm. Even with only a quarter megabecquerel of activity, 30-min bone SPECT scans provided surprisingly high levels of detail. Dynamic dual-isotope kidney and (99m)Tc-sestamibi cardiac scans were acquired with a time-frame resolution down to 1 s. CONCLUSION The high sensitivity achieved increases the range of mouse SPECT applications by enabling in vivo imaging with less than a megabecquerel of tracer activity or down to 1-s frame dynamics.
Collapse
Affiliation(s)
- Oleksandra Ivashchenko
- Section of Radiation, Detection, and Medical Imaging, Delft University of Technology, Delft, The Netherlands MILabs B.V., Utrecht, The Netherlands; and Department of Translational Neuroscience, Brain Center Rudolf Magnus, University Medical Center Utrecht, Utrecht, The Netherlands
| | - Frans van der Have
- Section of Radiation, Detection, and Medical Imaging, Delft University of Technology, Delft, The Netherlands MILabs B.V., Utrecht, The Netherlands; and Department of Translational Neuroscience, Brain Center Rudolf Magnus, University Medical Center Utrecht, Utrecht, The Netherlands
| | - Marlies C Goorden
- Section of Radiation, Detection, and Medical Imaging, Delft University of Technology, Delft, The Netherlands
| | - Ruud M Ramakers
- Section of Radiation, Detection, and Medical Imaging, Delft University of Technology, Delft, The Netherlands MILabs B.V., Utrecht, The Netherlands; and Department of Translational Neuroscience, Brain Center Rudolf Magnus, University Medical Center Utrecht, Utrecht, The Netherlands
| | - Freek J Beekman
- Section of Radiation, Detection, and Medical Imaging, Delft University of Technology, Delft, The Netherlands MILabs B.V., Utrecht, The Netherlands; and Department of Translational Neuroscience, Brain Center Rudolf Magnus, University Medical Center Utrecht, Utrecht, The Netherlands
| |
Collapse
|
25
|
van Oosterom MN, Kreuger R, Buckle T, Mahn WA, Bunschoten A, Josephson L, van Leeuwen FW, Beekman FJ. U-SPECT-BioFluo: an integrated radionuclide, bioluminescence, and fluorescence imaging platform. EJNMMI Res 2014; 4:56. [PMID: 25386389 PMCID: PMC4209452 DOI: 10.1186/s13550-014-0056-0] [Citation(s) in RCA: 14] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/14/2014] [Accepted: 09/28/2014] [Indexed: 01/11/2023] Open
Abstract
Background In vivo bioluminescence, fluorescence, and single-photon emission computed tomography (SPECT) imaging provide complementary information about biological processes. However, to date these signatures are evaluated separately on individual preclinical systems. In this paper, we introduce a fully integrated bioluminescence-fluorescence-SPECT platform. Next to an optimization in logistics and image fusion, this integration can help improve understanding of the optical imaging (OI) results. Methods An OI module was developed for a preclinical SPECT system (U-SPECT, MILabs, Utrecht, the Netherlands). The applicability of the module for bioluminescence and fluorescence imaging was evaluated in both a phantom and in an in vivo setting using mice implanted with a 4 T1-luc + tumor. A combination of a fluorescent dye and radioactive moiety was used to directly relate the optical images of the module to the SPECT findings. Bioluminescence imaging (BLI) was compared to the localization of the fluorescence signal in the tumors. Results Both the phantom and in vivo mouse studies showed that superficial fluorescence signals could be imaged accurately. The SPECT and bioluminescence images could be used to place the fluorescence findings in perspective, e.g. by showing tracer accumulation in non-target organs such as the liver and kidneys (SPECT) and giving a semi-quantitative read-out for tumor spread (bioluminescence). Conclusions We developed a fully integrated multimodal platform that provides complementary registered imaging of bioluminescent, fluorescent, and SPECT signatures in a single scanning session with a single dose of anesthesia. In our view, integration of these modalities helps to improve data interpretation of optical findings in relation to radionuclide images.
Collapse
Affiliation(s)
- Matthias N van Oosterom
- Radiation, Detection and Medical Imaging, Delft University of Technology, Mekelweg 15, Delft, 2629, JB, the Netherlands ; Interventional Molecular Imaging Laboratory, Department of Radiology, Leiden University Medical Center, Leiden, the Netherlands
| | - Rob Kreuger
- Radiation, Detection and Medical Imaging, Delft University of Technology, Mekelweg 15, Delft, 2629, JB, the Netherlands
| | - Tessa Buckle
- Interventional Molecular Imaging Laboratory, Department of Radiology, Leiden University Medical Center, Leiden, the Netherlands
| | - Wendy A Mahn
- Radiation, Detection and Medical Imaging, Delft University of Technology, Mekelweg 15, Delft, 2629, JB, the Netherlands
| | - Anton Bunschoten
- Interventional Molecular Imaging Laboratory, Department of Radiology, Leiden University Medical Center, Leiden, the Netherlands
| | - Lee Josephson
- Centre for Translational Nuclear Medicine and Molecular Imaging, Massachusetts General Hospital, Harvard Medical School, Boston, USA
| | - Fijs Wb van Leeuwen
- Interventional Molecular Imaging Laboratory, Department of Radiology, Leiden University Medical Center, Leiden, the Netherlands
| | - Freek J Beekman
- Radiation, Detection and Medical Imaging, Delft University of Technology, Mekelweg 15, Delft, 2629, JB, the Netherlands ; MILABS, Utrecht, the Netherlands ; Department of Translational Neuroscience, Brain Center Rudolf Magnus, University Medical Center Utrecht, Utrecht, the Netherlands
| |
Collapse
|
26
|
Bernsen MR, Vaissier PEB, Van Holen R, Booij J, Beekman FJ, de Jong M. The role of preclinical SPECT in oncological and neurological research in combination with either CT or MRI. Eur J Nucl Med Mol Imaging 2014; 41 Suppl 1:S36-49. [PMID: 24895751 PMCID: PMC4003405 DOI: 10.1007/s00259-013-2685-3] [Citation(s) in RCA: 24] [Impact Index Per Article: 2.2] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/19/2013] [Accepted: 12/20/2013] [Indexed: 01/03/2023]
Abstract
Preclinical imaging with SPECT combined with CT or MRI is used more and more frequently and has proven to be very useful in translational research. In this article, an overview of current preclinical research applications and trends of SPECT combined with CT or MRI, mainly in tumour imaging and neuroscience imaging, is given and the advantages and disadvantages of the different approaches are described. Today SPECT and CT systems are often integrated into a single device (commonly called a SPECT/CT system), whereas at present combined SPECT and MRI is almost always carried out with separate systems and fiducial markers to combine the separately acquired images. While preclinical SPECT/CT is most widely applied in oncology research, SPECT combined with MRI (SPECT/MRI when integrated in one system) offers the potential for both neuroscience applications and oncological applications. Today CT and MRI are still mainly used to localize radiotracer binding and to improve SPECT quantification, although both CT and MRI have additional potential. Future technology developments may include fast sequential or simultaneous acquisition of (dynamic) multimodality data, spectroscopy, fMRI along with high-resolution anatomic MRI, advanced CT procedures, and combinations of more than two modalities such as combinations of SPECT, PET, MRI and CT all together. This will all strongly depend on new technologies. With further advances in biology and chemistry for imaging molecular targets and (patho)physiological processes in vivo, the introduction of new imaging procedures and promising new radiopharmaceuticals in clinical practice may be accelerated.
Collapse
Affiliation(s)
- Monique R. Bernsen
- Department of Nuclear Medicine, Erasmus MC, Rotterdam, The Netherlands
- Department of Radiology, Erasmus MC, Rotterdam, The Netherlands
| | - Pieter E. B. Vaissier
- Section Radiation Detection and Medical Imaging, Delft University of Technology, Delft, The Netherlands
| | - Roel Van Holen
- ELIS Department, MEDISIP, Ghent University, iMinds, Ghent, Belgium
| | - Jan Booij
- Department of Nuclear Medicine, Academic Medical Center, University of Amsterdam, Amsterdam, The Netherlands
| | - Freek J. Beekman
- Section Radiation Detection and Medical Imaging, Delft University of Technology, Delft, The Netherlands
- MILabs B.V., Utrecht, The Netherlands
| | - Marion de Jong
- Department of Nuclear Medicine, Erasmus MC, Rotterdam, The Netherlands
- Department of Radiology, Erasmus MC, Rotterdam, The Netherlands
| |
Collapse
|
27
|
Branderhorst W, Blezer ELA, Houtkamp M, Ramakers RM, van den Brakel JH, Witteveen H, van der Have F, Gratama van Andel HA, Vastenhouw B, Wu C, Walsum MSV, van Dongen GAMS, Viergever MA, Bleeker WK, Beekman FJ. Three-dimensional histologic validation of high-resolution SPECT of antibody distributions within xenografts. J Nucl Med 2014; 55:830-7. [PMID: 24686779 DOI: 10.2967/jnumed.113.125401] [Citation(s) in RCA: 6] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/16/2022] Open
Abstract
UNLABELLED Longitudinal imaging of intratumoral distributions of antibodies in vivo in mouse cancer models is of great importance for developing cancer therapies. In this study, multipinhole SPECT with sub-half-millimeter resolution was tested for exploring intratumoral distributions of radiolabeled antibodies directed toward the epidermal growth factor receptor (EGFr) and compared with full 3-dimensional target expression assessed by immunohistochemistry. METHODS (111)In-labeled zalutumumab, a human monoclonal human EGFr-targeting antibody, was administered at a nonsaturating dose to 3 mice with xenografted A431 tumors exhibiting high EGFr expression. Total-body and focused in vivo tumor SPECT was performed at 0 and 48 h after injection and compared both visually and quantitatively with full 3-dimensional immunohistochemical staining for EGFr target expression. RESULTS SPECT at 48 h after injection showed that activity was predominantly concentrated in the tumor (10.5% ± 1.3% of the total-body activity; average concentration, 30.1% ± 4.6% of the injected dose per cubic centimeter). (111)In-labeled EGFr-targeting antibodies were distributed heterogeneously throughout the tumor. Some hot spots were observed near the tumor rim. Immunohistochemistry indicated that the antibody distributions obtained by SPECT were morphologically similar to those obtained for ex vivo EGFr target expression. Regions showing low SPECT activity were necrotic or virtually negative for EGFr target expression. A good correlation (r = 0.86, P < 0.0001) was found between the percentage of regions showing low activity on SPECT and the percentage of necrotic tissue on immunohistochemistry. CONCLUSION Multipinhole SPECT enables high-resolution visualization and quantification of the heterogeneity of (111)In-zalutumumab concentrations in vivo.
Collapse
Affiliation(s)
- Woutjan Branderhorst
- Image Sciences Institute, University Medical Center Utrecht, Utrecht, The Netherlands
| | | | | | | | | | | | | | | | | | | | | | | | | | | | | |
Collapse
|
28
|
Bowsher J, Yan S, Roper J, Giles W, Yin FF. Onboard functional and molecular imaging: a design investigation for robotic multipinhole SPECT. Med Phys 2014; 41:010701. [PMID: 24387490 DOI: 10.1118/1.4845195] [Citation(s) in RCA: 7] [Impact Index Per Article: 0.6] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/07/2022] Open
Abstract
PURPOSE Onboard imaging-currently performed primarily by x-ray transmission modalities-is essential in modern radiation therapy. As radiation therapy moves toward personalized medicine, molecular imaging, which views individual gene expression, may also be important onboard. Nuclear medicine methods, such as single photon emission computed tomography (SPECT), are premier modalities for molecular imaging. The purpose of this study is to investigate a robotic multipinhole approach to onboard SPECT. METHODS Computer-aided design (CAD) studies were performed to assess the feasibility of maneuvering a robotic SPECT system about a patient in position for radiation therapy. In order to obtain fast, high-quality SPECT images, a 49-pinhole SPECT camera was designed which provides high sensitivity to photons emitted from an imaging region of interest. This multipinhole system was investigated by computer-simulation studies. Seventeen hot spots 10 and 7 mm in diameter were placed in the breast region of a supine female phantom. Hot spot activity concentration was six times that of background. For the 49-pinhole camera and a reference, more conventional, broad field-of-view (FOV) SPECT system, projection data were computer simulated for 4-min scans and SPECT images were reconstructed. Hot-spot localization was evaluated using a nonprewhitening forced-choice numerical observer. RESULTS The CAD simulation studies found that robots could maneuver SPECT cameras about patients in position for radiation therapy. In the imaging studies, most hot spots were apparent in the 49-pinhole images. Average localization errors for 10-mm- and 7-mm-diameter hot spots were 0.4 and 1.7 mm, respectively, for the 49-pinhole system, and 3.1 and 5.7 mm, respectively, for the reference broad-FOV system. CONCLUSIONS A robot could maneuver a multipinhole SPECT system about a patient in position for radiation therapy. The system could provide onboard functional and molecular imaging with 4-min scan times.
Collapse
Affiliation(s)
- James Bowsher
- Department of Radiation Oncology, Duke University Medical Center, Durham, North Carolina 27710 and Medical Physics Graduate Program, Duke University, Durham, North Carolina 27710
| | - Susu Yan
- Medical Physics Graduate Program, Duke University, Durham, North Carolina 27710
| | - Justin Roper
- Department of Radiation Oncology, Duke University Medical Center, Durham, North Carolina 27710
| | - William Giles
- Department of Radiation Oncology, Duke University Medical Center, Durham, North Carolina 27710 and Medical Physics Graduate Program, Duke University, Durham, North Carolina 27710
| | - Fang-Fang Yin
- Department of Radiation Oncology, Duke University Medical Center, Durham, North Carolina 27710 and Medical Physics Graduate Program, Duke University, Durham, North Carolina 27710
| |
Collapse
|
29
|
Mejia J, Reis MA, Miranda ACC, Batista IR, Barboza MRF, Shih MC, Fu G, Chen CT, Meng LJ, Bressan RA, Amaro E. Performance assessment of the single photon emission microscope: high spatial resolution SPECT imaging of small animal organs. Braz J Med Biol Res 2013; 46:936-942. [PMID: 24270908 PMCID: PMC3854337 DOI: 10.1590/1414-431x20132764] [Citation(s) in RCA: 4] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/31/2012] [Accepted: 08/21/2013] [Indexed: 01/12/2023] Open
Abstract
The single photon emission microscope (SPEM) is an instrument developed to obtain
high spatial resolution single photon emission computed tomography (SPECT) images of
small structures inside the mouse brain. SPEM consists of two independent imaging
devices, which combine a multipinhole collimator, a high-resolution, thallium-doped
cesium iodide [CsI(Tl)] columnar scintillator, a demagnifying/intensifier tube, and
an electron-multiplying charge-coupling device (CCD). Collimators have 300- and
450-µm diameter pinholes on tungsten slabs, in hexagonal arrays of 19 and 7 holes.
Projection data are acquired in a photon-counting strategy, where CCD frames are
stored at 50 frames per second, with a radius of rotation of 35 mm and magnification
factor of one. The image reconstruction software tool is based on the maximum
likelihood algorithm. Our aim was to evaluate the spatial resolution and sensitivity
attainable with the seven-pinhole imaging device, together with the linearity for
quantification on the tomographic images, and to test the instrument in obtaining
tomographic images of different mouse organs. A spatial resolution better than 500 µm
and a sensitivity of 21.6 counts·s-1·MBq-1 were reached, as
well as a correlation coefficient between activity and intensity better than 0.99,
when imaging 99mTc sources. Images of the thyroid, heart, lungs, and bones
of mice were registered using 99mTc-labeled radiopharmaceuticals in times
appropriate for routine preclinical experimentation of <1 h per projection data
set. Detailed experimental protocols and images of the aforementioned organs are
shown. We plan to extend the instrument's field of view to fix larger animals and to
combine data from both detectors to reduce the acquisition time or applied
activity.
Collapse
Affiliation(s)
- J Mejia
- Hospital Israelita Albert Einstein, Instituto do Cérebro, São Paulo,SP, Brasil
| | | | | | | | | | | | | | | | | | | | | |
Collapse
|
30
|
Wu C, Gratama van Andel HA, Laverman P, Boerman OC, Beekman FJ. Effects of attenuation map accuracy on attenuation-corrected micro-SPECT images. EJNMMI Res 2013; 3:7. [PMID: 23369630 PMCID: PMC3579699 DOI: 10.1186/2191-219x-3-7] [Citation(s) in RCA: 4] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/10/2012] [Accepted: 01/23/2013] [Indexed: 12/18/2022] Open
Abstract
Background In single-photon emission computed tomography (SPECT), attenuation of photon flux in tissue affects quantitative accuracy of reconstructed images. Attenuation maps derived from X-ray computed tomography (CT) can be employed for attenuation correction. The attenuation coefficients as well as registration accuracy between SPECT and CT can be influenced by several factors. Here we investigate how such inaccuracies influence micro-SPECT quantification. Methods Effects of (1) misalignments between micro-SPECT and micro-CT through shifts and rotation, (2) globally altered attenuation coefficients and (3) combinations of these were evaluated. Tests were performed with a NEMA NU 4–2008 phantom and with rat cadavers containing sources with known activity. Results Changes in measured activities within volumes of interest in phantom images ranged from <1.5% (125I) and <0.6% (201Tl, 99mTc and 111In) for 1-mm shifts to <4.5% (125I) and <1.7% (201Tl, 99mTc and 111In) with large misregistration (3 mm). Changes induced by 15° rotation were smaller than those by 3-mm shifts. By significantly altering attenuation coefficients (±10%), activity changes of <5.2% for 125I and <2.7% for 201Tl, 99mTc and 111In were induced. Similar trends were seen in rat studies. Conclusions While getting sufficient accuracy of attenuation maps in clinical imaging is highly challenging, our results indicate that micro-SPECT quantification is quite robust to various imperfections of attenuation maps.
Collapse
Affiliation(s)
- Chao Wu
- Section Radiation, Detection & Medical Imaging, Delft University of Technology, Mekelweg 15, Delft, 2629 JB, the Netherlands.
| | | | | | | | | |
Collapse
|
31
|
Deleye S, Van Holen R, Verhaeghe J, Vandenberghe S, Stroobants S, Staelens S. Performance evaluation of small-animal multipinhole μSPECT scanners for mouse imaging. Eur J Nucl Med Mol Imaging 2013; 40:744-58. [PMID: 23344137 DOI: 10.1007/s00259-012-2326-2] [Citation(s) in RCA: 64] [Impact Index Per Article: 5.3] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/03/2012] [Accepted: 12/12/2012] [Indexed: 01/13/2023]
Abstract
PURPOSE We compared the performance of three commercial small-animal μSPECT scanners equipped with multipinhole general purpose (GP) and multipinhole high-resolution (HR) collimators designed for imaging mice. METHODS Spatial resolution, image uniformity, point source sensitivity and contrast recovery were determined for the U-SPECT-II (MILabs), the NanoSPECT-NSO (BioScan) and the X-SPECT (GE) scanners. The pinhole diameters of the HR collimator were 0.35 mm, 0.6 mm and 0.5 mm for these three systems respectively. A pinhole diameter of 1 mm was used for the GP collimator. To cover a broad field of imaging applications three isotopes were used with various photon energies: (99m)Tc (140 keV), (111)In (171 and 245 keV) and (125)I (27 keV). Spatial resolution and reconstructed image uniformity were evaluated in both HR and a GP mode with hot rod phantoms, line sources and a uniform phantom. Point source sensitivity and contrast recovery measures were additionally obtained in the GP mode with a novel contrast recovery phantom developed in-house containing hot and cold submillimetre capillaries on a warm background. RESULTS In hot rod phantom images, capillaries as small as 0.4 mm with the U-SPECT-II, 0.75 mm with the X-SPECT and 0.6 mm with the NanoSPECT-NSO could be resolved with the HR collimators for (99m)Tc. The NanoSPECT-NSO achieved this resolution in a smaller field-of-view (FOV) and line source measurements showed that this device had a lower axial than transaxial resolution. For all systems, the degradation in image resolution was only minor when acquiring the more challenging isotopes (111)In and (125)I. The point source sensitivity with (99m)Tc and GP collimators was 3,984 cps/MBq for the U-SPECT-II, 620 cps/MBq for the X-SPECT and 751 cps/MBq for the NanoSPECT-NSO. The effects of volume sensitivity over a larger object were evaluated by measuring the contrast recovery phantom in a realistic FOV and acquisition time. For 1.5-mm rods at a noise level of 8 %, the contrast recovery coefficient (CRC) was 42 %, 37 % and 34 % for the U-SPECT-II, X-SPECT and NanoSPECT-NSO, respectively. At maximal noise levels of 10 %, a CRCcold of 70 %, 52 % and 42 % were obtained for the U-SPECT-II, X-SPECT and NanoSPECT-NSO, respectively. When acquiring (99m)Tc with the GP collimators, the integral/differential uniformity values were 30 %/14 % for the U-SPECT-II, 50 %/30 % for the X-SPECT and 38 %/25 % for the NanoSPECT-NSO. When using the HR collimators, these uniformity values remained similar for U-SPECT-II and X-SPECT, but not for the NanoSPECT-NSO for which the uniformity deteriorated with larger volumes. CONCLUSION We compared three μSPECT systems by acquiring and analysing mouse-sized phantoms including a contrast recovery phantom built in-house offering the ability to measure the hot contrast on a warm background in the submillimetre resolution range. We believe our evaluation addressed the differences in imaging potential for each system to realistically image tracer distributions in mouse-sized objects.
Collapse
Affiliation(s)
- Steven Deleye
- Molecular Imaging Center Antwerp, Antwerp University, Universiteitsplein 1, 2610 Antwerp, Belgium.
| | | | | | | | | | | |
Collapse
|
32
|
Abstract
Conventional nuclear medical imaging uses radiopharmaceuticals labeled by single-photon emitters such as Tc-99m, I-123, or I-131 in vivo. Classical clinical examples are the study of bone metabolism by bone scintigraphy with the Tc-99m-labeled polyphosphonates or of iodine transport into the thyroid gland using Tc-99m-pertechnetate. With single-photon emission-computed tomography (SPECT), the distribution of these radiopharmaceuticals within the human body is three-dimensionally visualized. Contrary to positron emission tomography (PET), current SPECT technology does not allow the quantification of regional values of radioactivity tissue concentration as SPECT images are grossly compromised by artifacts caused by photon scatter and attenuation. With the advent of hybrid imaging systems combining a SPECT camera with an X-ray computerized (CT) scanner in one gantry, reliable corrections for these artifacts seem possible, allowing truly quantitative SPECT.
Collapse
Affiliation(s)
- Philipp Ritt
- Nuklearmedizinische Klinik, Universität Erlangen-Nürnberg, Erlangen, Germany.
| | | |
Collapse
|
33
|
Goorden MC, van der Have F, Kreuger R, Ramakers RM, Vastenhouw B, Burbach JPH, Booij J, Molthoff CFM, Beekman FJ. VECTor: A Preclinical Imaging System for Simultaneous Submillimeter SPECT and PET. J Nucl Med 2012; 54:306-12. [PMID: 23077113 DOI: 10.2967/jnumed.112.109538] [Citation(s) in RCA: 79] [Impact Index Per Article: 6.1] [Reference Citation Analysis] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/16/2022] Open
|
34
|
Penheiter AR, Russell SJ, Carlson SK. The sodium iodide symporter (NIS) as an imaging reporter for gene, viral, and cell-based therapies. Curr Gene Ther 2012; 12:33-47. [PMID: 22263922 PMCID: PMC3367315 DOI: 10.2174/156652312799789235] [Citation(s) in RCA: 106] [Impact Index Per Article: 8.2] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/17/2011] [Revised: 01/04/2012] [Accepted: 01/06/2012] [Indexed: 02/06/2023]
Abstract
Preclinical and clinical tomographic imaging systems increasingly are being utilized for non-invasive imaging of reporter gene products to reveal the distribution of molecular therapeutics within living subjects. Reporter gene and probe combinations can be employed to monitor vectors for gene, viral, and cell-based therapies. There are several reporter systems available; however, those employing radionuclides for positron emission tomography (PET) or singlephoton emission computed tomography (SPECT) offer the highest sensitivity and the greatest promise for deep tissue imaging in humans. Within the category of radionuclide reporters, the thyroidal sodium iodide symporter (NIS) has emerged as one of the most promising for preclinical and translational research. NIS has been incorporated into a remarkable variety of viral and non-viral vectors in which its functionality is conveniently determined by in vitro iodide uptake assays prior to live animal imaging. This review on the NIS reporter will focus on 1) differences between endogenous NIS and heterologously-expressed NIS, 2) qualitative or comparative use of NIS as an imaging reporter in preclinical and translational gene therapy, oncolytic viral therapy, and cell trafficking research, and 3) use of NIS as an absolute quantitative reporter.
Collapse
Affiliation(s)
- Alan R Penheiter
- Department of Molecular Medicine, Mayo Clinic, 200 First Street SW, Rochester, MN 55905, USA
| | | | | |
Collapse
|
35
|
Vaissier PEB, Goorden MC, Vastenhouw B, van der Have F, Ramakers RM, Beekman FJ. Fast spiral SPECT with stationary γ-cameras and focusing pinholes. J Nucl Med 2012; 53:1292-9. [PMID: 22707346 DOI: 10.2967/jnumed.111.101899] [Citation(s) in RCA: 33] [Impact Index Per Article: 2.5] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/16/2022] Open
Abstract
UNLABELLED Small-animal SPECT systems with stationary detectors and focusing multiple pinholes can achieve excellent resolution-sensitivity trade-offs. These systems are able to perform fast total-body scans by shifting the animal bed through the collimator using an automated xyz stage. However, so far, a large number of highly overlapping central fields of view have been used, at the cost of overhead time needed for animal repositioning and long image reconstruction times due to high numbers of projection views. METHODS To improve temporal resolution and reduce image reconstruction time for such scans, we have developed and tested spiral trajectories (STs) of the animal bed requiring fewer steps. In addition, we tested multiplane trajectories (MPTs) of the animal bed, which is the standard acquisition method of the U-SPECT-II system that is used in this study. Neither MPTs nor STs require rotation of the animal. Computer simulations and physical phantom experiments were performed for a wide range of numbers of bed positions. Furthermore, we tested STs in vivo for fast dynamic mouse scans. RESULTS We found that STs require less than half the number of bed positions of MPTs to achieve sufficient sampling. The reduced number of bed positions made it possible to perform a dynamic total-body bone scan and a dynamic hepatobiliary scan with time resolutions of 60 s and 15 s, respectively. CONCLUSION STs open up new possibilities for high throughput and fast dynamic radio-molecular imaging.
Collapse
|
36
|
Branderhorst W, van der Have F, Vastenhouw B, Viergever MA, Beekman FJ. Murine cardiac images obtained with focusing pinhole SPECT are barely influenced by extra-cardiac activity. Phys Med Biol 2012; 57:717-32. [DOI: 10.1088/0031-9155/57/3/717] [Citation(s) in RCA: 5] [Impact Index Per Article: 0.4] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/09/2023]
|
37
|
Teipel SJ, Buchert R, Thome J, Hampel H, Pahnke J. Development of Alzheimer-disease neuroimaging-biomarkers using mouse models with amyloid-precursor protein-transgene expression. Prog Neurobiol 2011; 95:547-56. [DOI: 10.1016/j.pneurobio.2011.05.004] [Citation(s) in RCA: 26] [Impact Index Per Article: 1.9] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/09/2011] [Revised: 05/04/2011] [Accepted: 05/05/2011] [Indexed: 11/16/2022]
|
38
|
Umeda IO, Tani K, Tsuda K, Kobayashi M, Ogata M, Kimura S, Yoshimoto M, Kojima S, Moribe K, Yamamoto K, Moriyama N, Fujii H. High resolution SPECT imaging for visualization of intratumoral heterogeneity using a SPECT/CT scanner dedicated for small animal imaging. Ann Nucl Med 2011; 26:67-76. [PMID: 21987284 DOI: 10.1007/s12149-011-0542-7] [Citation(s) in RCA: 19] [Impact Index Per Article: 1.4] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/04/2011] [Accepted: 09/21/2011] [Indexed: 11/28/2022]
Abstract
OBJECTIVES Tumor interiors are never homogeneous and in vivo visualization of intratumoral heterogeneity would be an innovation that contributes to improved cancer therapy. But, conventional nuclear medicine tests have failed to visualize heterogeneity in vivo because of limited spatial resolution. Recently developed single photon emission computed tomographic (SPECT) scanners dedicated for small animal imaging are of interest due to their excellent spatial resolution of <1 mm, but few studies have focused on the evaluation of intratumoral heterogeneity. We investigated the optimal conditions related to high resolution imaging of heterogeneous tumor interiors using a small animal SPECT scanner. METHODS The conditions related to SPECT/CT visualization of heterogeneous tumor interiors were investigated using phantoms with (111)In and simulations of actual small animal imaging. The optimal conditions obtained were validated by in vivo imaging of sarcoma 180-bearing mice. RESULTS Larger number of counts must be obtained within limited acquisition time to visualize tumor heterogeneity in vivo in animal imaging, compared to cases that simply detect tumors. At an acquisition time of 30 min, better image quality was obtained with pinhole apertures diameter of 1.4 mm than of 1.0 mm. The obtained best spatial resolution was 1.3 mm, it was acceptable for our purpose, though a little worse than the best possible performance of the scanner (1.0 mm). Additionally, the reconstruction parameters, such as noise suppression, voxel size, and iteration/subset number, needed to be optimized under the limited conditions and were different from those found under the ideal condition. The minimal radioactivity concentration for visualization of heterogeneous tumor interiors was estimated to be as high as 0.2-0.5 MBq/mL. Liposomes containing (111)In met this requirement and were administered to tumor-bearing mice. SPECT imaging successfully showed heterogeneous (111)In distribution within the tumors in vivo with good spatial resolution. A threshold of 0.2 MBq/g for clear visualization of tumor heterogeneity was validated. Autoradiograms obtained ex vivo of excised tumors confirmed that the in vivo SPECT images accurately depicted the heterogeneous intratumoral accumulation of liposomes. CONCLUSION Intratumoral heterogeneity was successfully visualized under the optimized conditions using a SPECT/CT scanner.
Collapse
Affiliation(s)
- Izumi O Umeda
- Functional Imaging Division, Research Center for Innovative Oncology, National Cancer Center Hospital East, Kashiwanoha, Kashiwa, Chiba, Japan.
| | | | | | | | | | | | | | | | | | | | | | | |
Collapse
|
39
|
Mok GSP, Tsui BMW, Beekman FJ. The effects of object activity distribution on multiplexing multi-pinhole SPECT. Phys Med Biol 2011; 56:2635-50. [PMID: 21454926 PMCID: PMC3095963 DOI: 10.1088/0031-9155/56/8/019] [Citation(s) in RCA: 34] [Impact Index Per Article: 2.4] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Download PDF] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/12/2022]
Abstract
We aim to study the effects of activity distribution for multiplexing multi-pinhole (MPH) SPECT. Three digital phantoms, including a hot rod, a cold rod and a cold sphere phantom, were used. Different degrees of multiplexing were obtained by (i) adjusting the MPH pattern for the same 4-pinhole collimator (scheme 1) and (ii) increasing the number of pinholes (scheme 2). Noise-free and noisy projections were generated using a 3D analytical MPH projector based on the same acquisition time. Projections were reconstructed using OS-EM without resolution recovery. Normalized mean-square-error (NMSE), noise, image profiles and signal-to-background ratios (SBR) were assessed. For the hot rod phantom, the NMSE-noise trade-offs slightly improves for multiplexing designs in scheme 2. Substantial artifacts were observed and the NMSE-noise trade-offs slightly worsened for multiplexing designs for the cold phantoms. Resolutions slightly degraded for higher degrees of multiplexing (∼39-65%) for the cold rod phantom. For the cold sphere phantom, image profiles showed non-multiplexing designs better emulated the phantom, while ∼20% multiplexing performs similarly as compared to non-multiplexing in SBR. Our results indicate that multiplexing can help for sparse objects but leads to a significant image degradation in non-sparse distributions. Since many tracers are not highly specific, and the gain of detection efficiency by allowing multiplexing is fairly offset by image degradations, multiplexing needs to be kept to a minimum for optimum MPH collimator designs.
Collapse
Affiliation(s)
- Greta S P Mok
- Department of Electrical and Electronics Engineering, Faculty of Science and Technology, University of Macau, Taipa, Macau, People's Republic of China.
| | | | | |
Collapse
|