Yang H, Wang L, Tang G, Zhou W, Tian Y, Zhang Y, Huang Y, Chen L, Wang M, Han Y, Wu H. Early 10-Minute Postinjection [ 18F]F-FAPI-42 uEXPLORER Total-Body PET/CT Scanning Protocol for Staging Lung Cancer Using HYPER Iterative Reconstruction. J Nucl Med Technol 2025:jnmt.125.269735. [PMID: 40345824 DOI: 10.2967/jnmt.125.269735] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/16/2025] [Accepted: 03/20/2025] [Indexed: 05/11/2025] Open
Abstract
Sensitive detection of small metastatic lesions, which is highly dependent on lesion visualization, is crucial for staging lung cancer. We investigated the potential benefit of HYPER Iterative for improving the visualization of small metastatic lesions of lung cancer on early 18F-labeled fibroblast activation protein inhibitor (FAPI) PET/CT. Methods: A total of 19 patients with lung cancer underwent a 60-min [18F]F-FAPI-42 dynamic total-body uEXPLORER PET/CT scan. PET images with a 5-min acquisition time were extracted at 10, 30 min, and 60 min after tracer injection. Ordered-subset expectation maximization (OSEM) and HYPER Iterative were used for image reconstruction. SUVmax, tumor-to-liver ratio, tumor-to-blood ratio, and tumor-to-adjacent-nontumor ratio were calculated and compared between the 2 reconstruction methods and at 10, 30, and 60 min after injection. Results: All HYPER and OSEM PET images were of high quality, with HYPER PET images showing superior clarity. Small positive lesions (maximum diameter, ≤1 cm) were depicted clearer on HYPER PET than on OSEM PET images at all time points, particularly at 10 min after injection, where 16.4% of lesions were poorly visualized on OSEM PET but clearly depicted on HYPER PET images. The tumor-to-liver ratio, tumor-to-blood ratio, and tumor-to-nontumor ratio at 10, 30, and 60 min after injection scan on HYPER PET images were significantly higher than those on OSEM images at corresponding time points (P ≥ 0.05 for all comparisons). SUVmax was more than 2-fold greater in large positive lesions (maximum diameter, >1.0 cm) than in small positive lesions (maximum diameter, ≤1 cm) on both OSEM and HYPER PET images at 10, 30, and 60 min after injection (P < 0.05 for all comparisons). The visualization of large positive lesions was not significantly affected by reconstruction methods or scan times. Conclusion: HYPER Iterative reconstruction enhanced the visualization of small metastatic lesions in lung cancer when compared with conventional OSEM, enabling effective early imaging using [18F]F-FAPI-42 uEXPLORER total-body PET/CT at 10 min after tracer injection.
Collapse
Affiliation(s)
- Hanyun Yang
- GDMPA Key Laboratory for Quality Control and Evaluation of Radiopharmaceuticals, Department of Nuclear Medicine, Nanfang Hospital, Southern Medical University, Guangzhou, China
| | - Lijuan Wang
- GDMPA Key Laboratory for Quality Control and Evaluation of Radiopharmaceuticals, Department of Nuclear Medicine, Nanfang Hospital, Southern Medical University, Guangzhou, China
| | - Ganghua Tang
- GDMPA Key Laboratory for Quality Control and Evaluation of Radiopharmaceuticals, Department of Nuclear Medicine, Nanfang Hospital, Southern Medical University, Guangzhou, China
| | - Wenlan Zhou
- GDMPA Key Laboratory for Quality Control and Evaluation of Radiopharmaceuticals, Department of Nuclear Medicine, Nanfang Hospital, Southern Medical University, Guangzhou, China
| | - Ying Tian
- GDMPA Key Laboratory for Quality Control and Evaluation of Radiopharmaceuticals, Department of Nuclear Medicine, Nanfang Hospital, Southern Medical University, Guangzhou, China
| | - Yin Zhang
- GDMPA Key Laboratory for Quality Control and Evaluation of Radiopharmaceuticals, Department of Nuclear Medicine, Nanfang Hospital, Southern Medical University, Guangzhou, China
| | - Yanchao Huang
- GDMPA Key Laboratory for Quality Control and Evaluation of Radiopharmaceuticals, Department of Nuclear Medicine, Nanfang Hospital, Southern Medical University, Guangzhou, China
| | - Li Chen
- GDMPA Key Laboratory for Quality Control and Evaluation of Radiopharmaceuticals, Department of Nuclear Medicine, Nanfang Hospital, Southern Medical University, Guangzhou, China
| | - Meng Wang
- GDMPA Key Laboratory for Quality Control and Evaluation of Radiopharmaceuticals, Department of Nuclear Medicine, Nanfang Hospital, Southern Medical University, Guangzhou, China
| | - Yanjiang Han
- GDMPA Key Laboratory for Quality Control and Evaluation of Radiopharmaceuticals, Department of Nuclear Medicine, Nanfang Hospital, Southern Medical University, Guangzhou, China
| | - Hubing Wu
- GDMPA Key Laboratory for Quality Control and Evaluation of Radiopharmaceuticals, Department of Nuclear Medicine, Nanfang Hospital, Southern Medical University, Guangzhou, China
| |
Collapse
|
2
|
Pommranz CM, Elmoujarkach EA, Lan W, Cabello J, Linder PM, Vo HP, Mannheim JG, Santangelo A, Conti M, la Fougère C, Rafecas M, Schmidt FP. A digital twin of the Biograph Vision Quadra long axial field of view PET/CT: Monte Carlo simulation and image reconstruction framework. EJNMMI Phys 2025; 12:31. [PMID: 40163262 PMCID: PMC11958866 DOI: 10.1186/s40658-025-00738-3] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/09/2024] [Accepted: 02/28/2025] [Indexed: 04/02/2025] Open
Abstract
BACKGROUND The high sensitivity and axial coverage of large axial field of view (LAFOV) PET scanners have an unmet potential for total-body PET research. Despite these technological advances, inherent challenges to PET scans such as patient motion persist. To provide simulation-derived ground truth information, we developed a digital replica of the Biograph Vision Quadra LAFOV PET/CT scanner closely mimicking real event processing and image reconstruction. MATERIAL AND METHODS The framework uses a GATE model in combination with vendor-specific software prototypes for event processing and image reconstruction (e7 tools, Siemens Healthineers). The framework was validated against experimental measurements following the NEMA NU-2 2018 standard. In addition, patient-like simulations were performed with the XCAT phantom, including respiratory motion and modeled lesions of 5, 10, 20 mm size, to assess the impact of motion artefacts on PET images using a motion-free reference. RESULTS The simulation framework demonstrated high accuracy in replicating scanner performance in terms of image quality, contrast recovery (37 mm sphere: 86.5% and 85.5%; 28 mm: 82.6% and 82.4%; 22 mm: 78.8% and 77.7%; 17 mm: 74.9% and 74.6%; 13 mm: 67.0% and 67.9%; 10 mm: 55.5% and 64.3%), image noise (CV of 7.5% and 7.7%) and sensitivity (174.6 cps/kBq and 175.3 cps/kBq) for the simulation and experimental data, respectively. High agreement was found for the spatial resolution with a difference of 0.4 ± 0.3 mm and the NECR aligned well with a maximum deviation of 9%, particularly in the clinical activity range below 10 kBq/mL. Motion induced artefacts resulted in a quantification error at lesion level between - 12.3% and - 45.1%. CONCLUSION The experimentally validated digital twin of the Biograph Vision Quadra facilitates detailed studies of realistic patient scenarios while offering unprecedented opportunities for motion correction, dosimetry, AI training, and imaging protocol optimization.
Collapse
Affiliation(s)
- Christian M Pommranz
- Department of Preclinical Imaging and Radiopharmacy, Werner Siemens Imaging Center, Eberhard Karls University Tuebingen, Roentgenweg 13, 72076, Tuebingen, Germany.
- Institute for Astronomy and Astrophysics, Eberhard Karls University Tuebingen, Sand 1, 72076, Tuebingen, Germany.
| | | | - Wenhong Lan
- Department of Nuclear Medicine and Clinical Molecular Imaging, University Hospital Tuebingen, Tuebingen, Germany
| | - Jorge Cabello
- Siemens Medical Solutions USA, Inc., Knoxville, TN, USA
| | - Pia M Linder
- Department of Nuclear Medicine and Clinical Molecular Imaging, University Hospital Tuebingen, Tuebingen, Germany
| | - Hong Phuc Vo
- Institute of Medical Engineering, University of Lübeck, Lübeck, Germany
| | - Julia G Mannheim
- Department of Preclinical Imaging and Radiopharmacy, Werner Siemens Imaging Center, Eberhard Karls University Tuebingen, Roentgenweg 13, 72076, Tuebingen, Germany
- Cluster of Excellence iFIT (EXC 2180) "Image Guided and Functionally Instructed Tumor Therapies", University of Tuebingen, Tuebingen, Germany
| | - Andrea Santangelo
- Institute for Astronomy and Astrophysics, Eberhard Karls University Tuebingen, Sand 1, 72076, Tuebingen, Germany
| | | | - Christian la Fougère
- Cluster of Excellence iFIT (EXC 2180) "Image Guided and Functionally Instructed Tumor Therapies", University of Tuebingen, Tuebingen, Germany
- Department of Nuclear Medicine and Clinical Molecular Imaging, University Hospital Tuebingen, Tuebingen, Germany
| | - Magdalena Rafecas
- Institute of Medical Engineering, University of Lübeck, Lübeck, Germany
| | - Fabian P Schmidt
- Department of Preclinical Imaging and Radiopharmacy, Werner Siemens Imaging Center, Eberhard Karls University Tuebingen, Roentgenweg 13, 72076, Tuebingen, Germany
- Department of Nuclear Medicine and Clinical Molecular Imaging, University Hospital Tuebingen, Tuebingen, Germany
| |
Collapse
|
3
|
Hicks RJ, Ware RE, Callahan J. Total-Body PET/CT: Pros and Cons. Semin Nucl Med 2025; 55:11-20. [PMID: 39289090 DOI: 10.1053/j.semnuclmed.2024.07.003] [Citation(s) in RCA: 6] [Impact Index Per Article: 6.0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/12/2024] [Accepted: 07/23/2024] [Indexed: 09/19/2024]
Abstract
PET/CT devices with an axial field-of-view (FOV) of 1 m allow simultaneous imaging from the head to the upper thighs, the typical axial extent of many "whole-body" oncological studies acquired by moving a patient sequentially through a conventional FOV device, or rapid total-body imaging using the same approach. Increasing the FOV to around 2 m provides true simultaneous total-body imaging. Either approach dramatically increases the sensitivity for detection of annihilation events arising within the body. For the purposes of this review, both configurations are considered to represent "total-body" PET/CT devices because they share both advantages and disadvantages. These pros and cons are discussed in the context of both clinical and research applications from a patient and institutional perspective.
Collapse
Affiliation(s)
- Rodney J Hicks
- The Melbourne Theranostic Innovation Centre, North Melbourne, Victoria 3051, Australia; St Vincent's Hospital, Department of Medicine, The University of Melbourne, Fitzroy, Victoria 3065, Australia.
| | - Robert E Ware
- The Melbourne Theranostic Innovation Centre, North Melbourne, Victoria 3051, Australia
| | - Jason Callahan
- The Melbourne Theranostic Innovation Centre, North Melbourne, Victoria 3051, Australia
| |
Collapse
|
4
|
Zheng Z, Gao H, Lin Y, Yu H, Mao W, Yang R, He Y, Chen X, Wu H, Hu P, Shi H. The earliest optimal timing for total-body 68Ga-fibroblast activation protein inhibitor-04 PET scans: an evidence-based single-centre study. Eur Radiol 2024; 34:4550-4560. [PMID: 38110627 DOI: 10.1007/s00330-023-10264-4] [Citation(s) in RCA: 2] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/28/2022] [Revised: 07/07/2023] [Accepted: 07/20/2023] [Indexed: 12/20/2023]
Abstract
OBJECTIVES To investigate the earliest optimal timing for positron emission tomography (PET) scans after 68Ga-fibroblast activation protein inhibitor-04 ([68Ga]Ga-FAPI-04) injection. METHODS This prospective study enrolled patients who underwent 60-min dynamic 68Ga-FAPI-04 total-body PET/CT scans; the images were reconstructed at 10-min intervals (G0-10, G10-20, G20-30, G30-40, G40-50, and G50-60), and the [68Ga]Ga-FAPI-04 uptake patterns were evaluated. The standardised uptake value (SUV), liver signal-to-noise ratio (SNR), and lesion-to-background ratios (LBRs) for different time windows were calculated to evaluate image quality and lesion detectability. The period from 30 to 40 min was then split into overlapping 5-min intervals starting 1 min apart for further evaluation. G50-60 was considered the reference. RESULTS A total of 30 patients with suspected malignant tumours were analysed. In the images reconstructed over 10-min intervals, longer acquisition times were associated with lower background uptake and better image quality. Some lesions could not be detected until G30-40. The lesion detection rate, uptake, and LBRs did not differ significantly among G30-40, G40-50, and G50-60 (all p > 0.05). The SUVmean and LBRs of primary tumours in the reconstructed images did not differ significantly among the 5-min intervals between 30 and 40 min; for metastatic and benign lesions, G34-39 and G35-40 showed significantly better SUVmean and LBR values than the other images. The G34-39 and G50-60 scans showed no significant differences in uptake, LBRs, or detection rates (all p > 0.05). CONCLUSION The earliest optimal time to start acquisition was 34 min after injection of half-dose [68Ga]Ga-FAPI-04. CLINICAL RELEVANCE STATEMENT This study evaluated 68Ga-fibroblast activation protein inhibitor-04 ([68Ga]Ga-FAPI-04) uptake patterns by comparing the image quality and lesion detection rate with 60-min dynamic [68Ga]Ga-FAPI-04 total-body PET/CT scans and identified the earliest optimal scan time after [68Ga]Ga-FAPI-04 injection. KEY POINTS • A prospective single-centre study showed that the earliest optimal time point to start acquisition was 34 min after injection of half-dose [68Ga-fibroblast activation protein inhibitor-04 (68Ga]Ga-FAPI-04). • There were statistically significant differences in standardised uptake value, lesion-to-background ratios, and lesion detectability between scans before and after 34 min from the injection of [68Ga]Ga-FAPI-04, but these values did not change further from 34 to 60 min after injection. • With a reasonable acquisition time, the image quality could still meet diagnostic requirements.
Collapse
Affiliation(s)
- Zhe Zheng
- Department of Nuclear Medicine, Zhongshan Hospital, Fudan University, 180 Fenglin Road, Shanghai, 200032, China
- Shanghai Institute of Medical Imaging, Shanghai, 200032, China
- Nuclear Medicine Institute of Fudan University, Shanghai, 200032, China
- Cancer Prevention and Treatment Center, Zhongshan Hospital, Fudan University, Shanghai, 200032, China
| | - Huaping Gao
- Department of Nuclear Medicine, Zhongshan Hospital, Fudan University, 180 Fenglin Road, Shanghai, 200032, China
- Shanghai Institute of Medical Imaging, Shanghai, 200032, China
- Nuclear Medicine Institute of Fudan University, Shanghai, 200032, China
- Cancer Prevention and Treatment Center, Zhongshan Hospital, Fudan University, Shanghai, 200032, China
| | - Yu Lin
- Department of Nuclear Medicine, Zhongshan Hospital, Fudan University, 180 Fenglin Road, Shanghai, 200032, China
- Shanghai Institute of Medical Imaging, Shanghai, 200032, China
- Nuclear Medicine Institute of Fudan University, Shanghai, 200032, China
- Cancer Prevention and Treatment Center, Zhongshan Hospital, Fudan University, Shanghai, 200032, China
| | - Haojun Yu
- Department of Nuclear Medicine, Zhongshan Hospital, Fudan University, 180 Fenglin Road, Shanghai, 200032, China
- Shanghai Institute of Medical Imaging, Shanghai, 200032, China
- Nuclear Medicine Institute of Fudan University, Shanghai, 200032, China
- Cancer Prevention and Treatment Center, Zhongshan Hospital, Fudan University, Shanghai, 200032, China
| | - Wujian Mao
- Department of Nuclear Medicine, Zhongshan Hospital, Fudan University, 180 Fenglin Road, Shanghai, 200032, China
- Shanghai Institute of Medical Imaging, Shanghai, 200032, China
- Nuclear Medicine Institute of Fudan University, Shanghai, 200032, China
- Cancer Prevention and Treatment Center, Zhongshan Hospital, Fudan University, Shanghai, 200032, China
| | - Runjun Yang
- Department of Nuclear Medicine, Zhongshan Hospital, Fudan University, 180 Fenglin Road, Shanghai, 200032, China
- Shanghai Institute of Medical Imaging, Shanghai, 200032, China
- Nuclear Medicine Institute of Fudan University, Shanghai, 200032, China
- Cancer Prevention and Treatment Center, Zhongshan Hospital, Fudan University, Shanghai, 200032, China
| | - Yibo He
- Department of Nuclear Medicine, Zhongshan Hospital, Fudan University, 180 Fenglin Road, Shanghai, 200032, China
- Shanghai Institute of Medical Imaging, Shanghai, 200032, China
- Nuclear Medicine Institute of Fudan University, Shanghai, 200032, China
- Cancer Prevention and Treatment Center, Zhongshan Hospital, Fudan University, Shanghai, 200032, China
| | - Xueqi Chen
- Department of Nuclear Medicine, Zhongshan Hospital, Fudan University, 180 Fenglin Road, Shanghai, 200032, China
- Shanghai Institute of Medical Imaging, Shanghai, 200032, China
- Nuclear Medicine Institute of Fudan University, Shanghai, 200032, China
- Cancer Prevention and Treatment Center, Zhongshan Hospital, Fudan University, Shanghai, 200032, China
| | - Ha Wu
- Department of Nuclear Medicine, Zhongshan Hospital, Fudan University, 180 Fenglin Road, Shanghai, 200032, China
- Shanghai Institute of Medical Imaging, Shanghai, 200032, China
- Nuclear Medicine Institute of Fudan University, Shanghai, 200032, China
- Cancer Prevention and Treatment Center, Zhongshan Hospital, Fudan University, Shanghai, 200032, China
| | - Pengcheng Hu
- Department of Nuclear Medicine, Zhongshan Hospital, Fudan University, 180 Fenglin Road, Shanghai, 200032, China.
- Shanghai Institute of Medical Imaging, Shanghai, 200032, China.
- Nuclear Medicine Institute of Fudan University, Shanghai, 200032, China.
- Cancer Prevention and Treatment Center, Zhongshan Hospital, Fudan University, Shanghai, 200032, China.
| | - Hongcheng Shi
- Department of Nuclear Medicine, Zhongshan Hospital, Fudan University, 180 Fenglin Road, Shanghai, 200032, China.
- Shanghai Institute of Medical Imaging, Shanghai, 200032, China.
- Nuclear Medicine Institute of Fudan University, Shanghai, 200032, China.
- Cancer Prevention and Treatment Center, Zhongshan Hospital, Fudan University, Shanghai, 200032, China.
| |
Collapse
|
5
|
Meng X, Kong X, Xia L, Wu R, Zhu H, Yang Z. The Role of Total-Body PET in Drug Development and Evaluation: Status and Outlook. J Nucl Med 2024; 65:46S-53S. [PMID: 38719239 DOI: 10.2967/jnumed.123.266978] [Citation(s) in RCA: 2] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/31/2023] [Revised: 01/23/2024] [Indexed: 07/16/2024] Open
Abstract
Total-body PET, an emerging technique, enables high-quality simultaneous total-body dynamic PET acquisition and accurate kinetic analysis. It has the potential to facilitate the study of multiple tracers while minimizing radiation dose and improving tracer-specific imaging. This advancement holds promise for enhancing the development and clinical evaluation of drugs, particularly radiopharmaceuticals. Multiple clinical trials are using a total-body PET scanner to explore existing and innovative radiopharmaceuticals. However, challenges persist, along with the opportunities, with regard to the use of total-body PET in drug development and evaluation. Specifically, considerations relate to the role of total-body PET in clinical pharmacologic evaluations and its integration into the theranostic paradigm. In this review, state-of-the-art total-body PET and its potential roles in pharmaceutical research are explored.
Collapse
Affiliation(s)
- Xiangxi Meng
- Key Laboratory of Carcinogenesis and Translational Research (Ministry of Education/Beijing), National Medical Products Association, Key Laboratory for Research and Evaluation of Radiopharmaceuticals, National Medical Products Association, Department of Nuclear Medicine, Peking University Cancer Hospital & Institute, Beijing, China; and
| | - Xiangxing Kong
- Key Laboratory of Carcinogenesis and Translational Research (Ministry of Education/Beijing), National Medical Products Association, Key Laboratory for Research and Evaluation of Radiopharmaceuticals, National Medical Products Association, Department of Nuclear Medicine, Peking University Cancer Hospital & Institute, Beijing, China; and
| | - Lei Xia
- Key Laboratory of Carcinogenesis and Translational Research (Ministry of Education/Beijing), National Medical Products Association, Key Laboratory for Research and Evaluation of Radiopharmaceuticals, National Medical Products Association, Department of Nuclear Medicine, Peking University Cancer Hospital & Institute, Beijing, China; and
| | - Runze Wu
- Beijing United Imaging Research Institute of Intelligent Imaging, Beijing, China
| | - Hua Zhu
- Key Laboratory of Carcinogenesis and Translational Research (Ministry of Education/Beijing), National Medical Products Association, Key Laboratory for Research and Evaluation of Radiopharmaceuticals, National Medical Products Association, Department of Nuclear Medicine, Peking University Cancer Hospital & Institute, Beijing, China; and
| | - Zhi Yang
- Key Laboratory of Carcinogenesis and Translational Research (Ministry of Education/Beijing), National Medical Products Association, Key Laboratory for Research and Evaluation of Radiopharmaceuticals, National Medical Products Association, Department of Nuclear Medicine, Peking University Cancer Hospital & Institute, Beijing, China; and
| |
Collapse
|
6
|
Wu Y, Sun T, Ng YL, Liu J, Zhu X, Cheng Z, Xu B, Meng N, Zhou Y, Wang M. Clinical Implementation of Total-Body PET in China. J Nucl Med 2024; 65:64S-71S. [PMID: 38719242 DOI: 10.2967/jnumed.123.266977] [Citation(s) in RCA: 1] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/04/2023] [Revised: 02/13/2024] [Indexed: 07/16/2024] Open
Abstract
Total-body (TB) PET/CT is a groundbreaking tool that has brought about a revolution in both clinical application and scientific research. The transformative impact of TB PET/CT in the realms of clinical practice and scientific exploration has been steadily unfolding since its introduction in 2018, with implications for its implementation within the health care landscape of China. TB PET/CT's exceptional sensitivity enables the acquisition of high-quality images in significantly reduced time frames. Clinical applications have underscored its effectiveness across various scenarios, emphasizing the capacity to personalize dosage, scan duration, and image quality to optimize patient outcomes. TB PET/CT's ability to perform dynamic scans with high temporal and spatial resolution and to perform parametric imaging facilitates the exploration of radiotracer biodistribution and kinetic parameters throughout the body. The comprehensive TB coverage offers opportunities to study interconnections among organs, enhancing our understanding of human physiology and pathology. These insights have the potential to benefit applications requiring holistic TB assessments. The standard topics outlined in The Journal of Nuclear Medicine were used to categorized the reviewed articles into 3 sections: current clinical applications, scan protocol design, and advanced topics. This article delves into the bottleneck that impedes the full use of TB PET in China, accompanied by suggested solutions.
Collapse
Affiliation(s)
- Yaping Wu
- Department of Medical Imaging, Henan Provincial People's Hospital, Zhengzhou, China
- People's Hospital of Zhengzhou University, Zhengzhou, China
- Institute for Integrated Medical Science and Engineering, Henan Academy of Sciences, Zhengzhou, China
| | - Tao Sun
- Shenzhen Institute of Advanced Technology, Chinese Academy of Sciences, Shenzhen, China
| | - Yee Ling Ng
- Central Research Institute, United Imaging Healthcare Group Co., Ltd., Shanghai, China
| | - Jianjun Liu
- Department of Nuclear Medicine, RenJi Hospital, School of Medicine, Shanghai Jiao Tong University, Shanghai, China
| | - Xiaohua Zhu
- Department of Nuclear Medicine, Tongji Hospital, Tongji Medical College, Huazhong University of Science and Technology, Wuhan, China
| | - Zhaoping Cheng
- Department of Nuclear Medicine, First Affiliated Hospital of Shandong First Medical University and Shandong Provincial Qianfoshan Hospital, Jinan, China; and
| | - Baixuan Xu
- Department of Nuclear Medicine, Chinese PLA General Hospital, Beijing, China
| | - Nan Meng
- Department of Medical Imaging, Henan Provincial People's Hospital, Zhengzhou, China
- People's Hospital of Zhengzhou University, Zhengzhou, China
- Institute for Integrated Medical Science and Engineering, Henan Academy of Sciences, Zhengzhou, China
| | - Yun Zhou
- Central Research Institute, United Imaging Healthcare Group Co., Ltd., Shanghai, China
| | - Meiyun Wang
- Department of Medical Imaging, Henan Provincial People's Hospital, Zhengzhou, China;
- People's Hospital of Zhengzhou University, Zhengzhou, China
- Institute for Integrated Medical Science and Engineering, Henan Academy of Sciences, Zhengzhou, China
| |
Collapse
|
7
|
Slart RHJA, Bengel FM, Akincioglu C, Bourque JM, Chen W, Dweck MR, Hacker M, Malhotra S, Miller EJ, Pelletier-Galarneau M, Packard RRS, Schindler TH, Weinberg RL, Saraste A, Slomka PJ. Total-Body PET/CT Applications in Cardiovascular Diseases: A Perspective Document of the SNMMI Cardiovascular Council. J Nucl Med 2024:jnumed.123.266858. [PMID: 38388512 DOI: 10.2967/jnumed.123.266858] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/07/2023] [Accepted: 01/11/2024] [Indexed: 02/24/2024] Open
Abstract
Digital PET/CT systems with a long axial field of view have become available and are emerging as the current state of the art. These new camera systems provide wider anatomic coverage, leading to major increases in system sensitivity. Preliminary results have demonstrated improvements in image quality and quantification, as well as substantial advantages in tracer kinetic modeling from dynamic imaging. These systems also potentially allow for low-dose examinations and major reductions in acquisition time. Thereby, they hold great promise to improve PET-based interrogation of cardiac physiology and biology. Additionally, the whole-body coverage enables simultaneous assessment of multiple organs and the large vascular structures of the body, opening new opportunities for imaging systemic mechanisms, disorders, or treatments and their interactions with the cardiovascular system as a whole. The aim of this perspective document is to debate the potential applications, challenges, opportunities, and remaining challenges of applying PET/CT with a long axial field of view to the field of cardiovascular disease.
Collapse
Affiliation(s)
- Riemer H J A Slart
- Medical Imaging Centre, Department of Nuclear Medicine and Molecular Imaging, University Medical Center Groningen, University of Groningen, Groningen, The Netherlands;
- Biomedical Photonic Imaging Group, Faculty of Science and Technology, University of Twente, Enschede, The Netherlands
| | - Frank M Bengel
- Department of Nuclear Medicine, Hannover Medical School, Hannover, Germany
| | - Cigdem Akincioglu
- Division of Nuclear Medicine, Medical Imaging, Western University, London, Ontario, Canada
| | - Jamieson M Bourque
- Departments of Medicine (Cardiology) and Radiology, University of Virginia, Charlottesville, Virginia
| | - Wengen Chen
- Department of Diagnostic Radiology and Nuclear Medicine, University of Maryland School of Medicine, Baltimore, Maryland
| | - Marc R Dweck
- British Heart Foundation Centre for Cardiovascular Science, Edinburgh Heart Centre, University of Edinburgh, Edinburgh, United Kingdom
| | - Marcus Hacker
- Division of Nuclear Medicine, Department of Biomedical Imaging and Image-Guided Therapy, Medical University of Vienna, Vienna, Austria
| | | | - Edward J Miller
- Department of Biomedical Engineering, Yale University, New Haven, Connecticut; Department of Radiology and Biomedical Imaging, Yale School of Medicine, and Department of Internal Medicine, Yale University, New Haven, Connecticut
| | | | - René R S Packard
- Division of Cardiology, Department of Medicine, David Geffen School of Medicine, UCLA, Los Angeles, California
| | - Thomas H Schindler
- Mallinckrodt Institute of Radiology, Division of Nuclear Medicine, Cardiovascular Medicine, Washington University School of Medicine, St. Louis, Missouri
| | - Richard L Weinberg
- Division of Cardiology, Feinberg School of Medicine, Northwestern University, Chicago, Illinois
| | - Antti Saraste
- Turku PET Centre and Heart Center, Turku University Hospital and University of Turku, Turku, Finland; and
| | - Piotr J Slomka
- Division of Artificial Intelligence in Medicine, Department of Medicine, Cedars-Sinai Medical Center, Los Angeles, California
| |
Collapse
|
8
|
Cherry SR, Diekmann J, Bengel FM. Total-Body Positron Emission Tomography: Adding New Perspectives to Cardiovascular Research. JACC Cardiovasc Imaging 2023; 16:1335-1347. [PMID: 37676207 DOI: 10.1016/j.jcmg.2023.06.022] [Citation(s) in RCA: 15] [Impact Index Per Article: 7.5] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 05/08/2023] [Revised: 06/26/2023] [Accepted: 06/27/2023] [Indexed: 09/08/2023]
Abstract
The recent advent of positron emission tomography (PET) scanners that can image the entire human body opens up intriguing possibilities for cardiovascular research and future clinical applications. These new systems permit radiotracer kinetics to be measured in all organs simultaneously. They are particularly well suited to study cardiovascular disease and its effects on the entire body. They could also play a role in quantitatively measuring physiologic, metabolic, and immunologic responses in healthy individuals to a variety of stressors and lifestyle interventions, and may ultimately be instrumental for evaluating novel therapeutic agents and their molecular effects across different tissues. In this review, we summarize recent progress in PET technology and methodology, discuss several emerging cardiovascular applications for total-body PET, and place this in the context of multiorgan and systems medicine. Finally, we discuss opportunities that will be enabled by the technology, while also pointing to some of the challenges that still need to be addressed.
Collapse
Affiliation(s)
- Simon R Cherry
- Departments of Biomedical Engineering and Radiology, University of California, Davis, California, USA.
| | - Johanna Diekmann
- Departments of Biomedical Engineering and Radiology, University of California, Davis, California, USA; Department of Nuclear Medicine, Hannover Medical School, Hannover, Germany
| | - Frank M Bengel
- Department of Nuclear Medicine, Hannover Medical School, Hannover, Germany
| |
Collapse
|